1
|
Alhasan A, Sani SFA, Tajuddin HA, Ali TH. Development of nanoparticles and quantum dots as alternatives to iodinated contrast agents for mono-modal and bi-modal computed tomography imaging. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2025:102831. [PMID: 40513631 DOI: 10.1016/j.nano.2025.102831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2025] [Revised: 05/08/2025] [Accepted: 06/01/2025] [Indexed: 06/16/2025]
Abstract
Medical imaging plays a pivotal role in disease screening, early detection, and diagnosis. Among the various imaging modalities, computed tomography (CT) is one of the most widely utilized in clinical practice, offering high-resolution anatomical images critical for disease investigation. To enhance the visibility of tissues with similar densities, contrast agents are often required. Iodinated contrast agents, the most commonly used, are effective but have significant limitations, including short circulation times, the need for high-concentration injections, restricted tissue targeting, and potential side effects such as nephrotoxicity. These challenges have spurred the development of next-generation contrast agents. Nanostructured materials, particularly nanoparticles and quantum dots, have emerged as promising alternatives due to their superior X-ray attenuation, extended circulation times, and potential for multi-modal imaging applications such as CT/MRI and CT/fluorescence. Their unique properties, including small size, large surface area, and tunable functionalization enable targeted imaging and reduced side effects, making them ideal candidates for advanced diagnostics. This review highlights the recent advancements in synthesizing and optimizing nanostructured contrast agents based on their elemental composition, synthesis techniques, and imaging properties. It underscores the transformative potential of nano-based agents in enhancing diagnostic accuracy while minimizing adverse effects, marking a significant step forward in medical imaging technology.
Collapse
Affiliation(s)
- Ammar Alhasan
- College of Pharmacy, Al-Muthanna University, 66001 Samawah, Al-Muthanna, Iraq; Department of Physics, Faculty of Science, Universiti Malaya, 50603 Kuala Lumpur, Malaysia
| | - S F Abdul Sani
- Department of Physics, Faculty of Science, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
| | - Hairul Anuar Tajuddin
- Centre for Fundamental and Frontier Sciences in Nanostructure Self-Assembly, Department of Chemistry, Faculty of Science, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
| | - Tammar Hussein Ali
- College of Pharmacy, Al-Muthanna University, 66001 Samawah, Al-Muthanna, Iraq
| |
Collapse
|
2
|
Heimer MM, Sun Y, Bonitatibus PJ, Yeh BM. Oral CT Contrast Agents: What's New and Why, From the AJR Special Series on Contrast Media. AJR Am J Roentgenol 2024; 223:e2329970. [PMID: 37877595 DOI: 10.2214/ajr.23.29970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2023]
Abstract
Current CT oral contrast agents improve the conspicuity of and confidence in bowel and peritoneal findings in many clinical scenarios, particularly for outpatient and oncologic abdominopelvic imaging. Yet, existing positive and neutral oral contrast agents may diminish the detectability of certain radiologic findings, frequently in the same scans in which the oral contrast agent improves the detectability of other findings. With ongoing improvements in CT technology, particularly multienergy CT, opportunities are opening for new types of oral contrast agents to further improve anatomic delineation and disease detection using CT. The CT signal of new dark oral contrast agents and of new high-Z oral contrast agents promises to combine the strengths of both positive and neutral oral CT contrast agents by providing distinct CT appearances in comparison with bodily tissues, iodinated IV contrast agents, and other classes of new CT contrast agents. High-Z oral contrast agents will unlock previously inaccessible capabilities of multienergy CT, particularly photon-counting detector CT, for differentiating simultaneously administered IV and oral contrast agents; this technique will allow generation of rich 3D, intuitive, perfectly coregistered, high-resolution image sets with individual contrast agent "colors" that provide compelling clarity for intertwined intraabdominal anatomy and disease processes.
Collapse
Affiliation(s)
- Maurice M Heimer
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, M-372, San Francisco, CA 94143-0628
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany
| | - Yuxin Sun
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, M-372, San Francisco, CA 94143-0628
| | | | - Benjamin M Yeh
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, 513 Parnassus Ave, M-372, San Francisco, CA 94143-0628
| |
Collapse
|
3
|
Safari A, Mahdavi M, Fardid R, Oveisi A, Jalli R, Haghani M. Evaluation of hafnium oxide nanoparticles imaging characteristics as a contrast agent in X-ray computed tomography. Radiol Phys Technol 2024; 17:441-450. [PMID: 38630390 DOI: 10.1007/s12194-024-00797-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 05/27/2024]
Abstract
This research aimed to compare the quantitative imaging attributes of synthesized hafnium oxide nanoparticles (NPs) derived from UiO-66-NH2(Hf) and two gadolinium- and iodine-based clinical contrast agents (CAs) using cylindrical phantom. Aqueous solutions of the studied CAs, containing 2.5, 5, and 10 mg/mL of HfO2NPs, gadolinium, and iodine, were prepared. Constructed within a cylindrical phantom, 15 cc small tubes were filled with CAs. Maintaining constant mAs, the phantom underwent scanning at tube voltage variations from 80 to 140 kVp. The CT numbers were quantified in Hounsfield units (HU), and the contrast-to-noise ratios (CNR) were calculated within delineated regions of interest (ROI) for all CAs. The HfO2NPs at 140 kVp and concentration of 2.5 mg/ml exhibited 2.3- and 1.3-times higher CT numbers than iodine and gadolinium, respectively. Notably, gadolinium consistently displayed higher CT numbers than iodine across all exposure techniques and concentrations. At the highest tube potential, the maximum amount of the CAs CT numbers was attained, and at 140 kVp and concentration of 2.5 mg/ml of HfO2NPs the CNR surpassed iodine by 114%, and gadolinium by 30%, respectively. HfO2NPs, as a contrast agent, demonstrated superior image quality in terms of contrast and noise in comparison to iodine- and gadolinium-based contrast media, particularly at higher energies of X-ray in computed tomography. Thus, its utilization is highly recommended in CT.
Collapse
Affiliation(s)
- Arash Safari
- Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
- Department of Radiology, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Maziyar Mahdavi
- Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
- Department of Radiology, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Reza Fardid
- Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
- Department of Radiology, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Alireza Oveisi
- Department of Chemistry, Faculty of Sciences, University of Zabol, P.O. Box: 98615-538, Zabol, Iran.
| | - Reza Jalli
- Department of Radiology, Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Masoud Haghani
- Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
- Department of Radiology, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
4
|
England A, Rawashdeh M, Moore N, Young R, Curran G, McEntee MF. More sustainable use of iodinated contrast media - Why? Radiography (Lond) 2024; 30 Suppl 1:74-80. [PMID: 38991461 DOI: 10.1016/j.radi.2024.06.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/27/2024] [Accepted: 06/28/2024] [Indexed: 07/13/2024]
Abstract
OBJECTIVES Based on a narrative review of the literature to 1) assess the need for and 2) report methods to help deliver a sustainable approach to iodinated contrast media (ICM) administration. KEY FINDINGS Acute ICM shortages have been noted in the literature. As demand for contrast-enhanced imaging continues to increase and access to raw materials becomes more limited, such events may increase. Evidence from the literature has documented a range of iodinated contrast reduction strategies. These include individualised contrast-media dosing, multi-dose bulk ICM vials, switching to alternative modalities or the increased use of non-contrast examinations. The optimisation of imaging parameters, the use of saline chasers, and alternative contrast agents should be further considered. Given the rising concerns regarding the presence and effects of ICMs in waste and drinking water, further consideration of strategies for managing waste and excreted ICMs are starting to emerge. CONCLUSIONS Sustainable ICM practices are needed to help avoid supply shortages and to help protect our environment. Such practices must be led and supported locally, nationally, and internationally. Sustainable ICM practices must be reflected within professional Standards of Proficiencies and be adopted by all members of the multidisciplinary team. IMPLICATIONS FOR PRACTICE Changes to working practices surrounding the sustainable use of ICMs will likely become commonplace. New methods to ensure optimised ICM dosage with minimal wastage will be more heavily featured in departmental practices. Correct disposal of waste and excreted ICMs will also form part of future changes to practice.
Collapse
Affiliation(s)
- A England
- Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland.
| | - M Rawashdeh
- Department of Medical Imaging Sciences, Gulf Medical University, Ajman, United Arab Emirates
| | - N Moore
- Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland
| | - R Young
- Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland
| | - G Curran
- Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland
| | - M F McEntee
- Discipline of Medical Imaging & Radiation Therapy, University College Cork, Cork, Ireland; Faculty of Health Sciences, University of Southern Denmark, Denmark; Faculty of Medicine, University of Sydney, Australia
| |
Collapse
|
5
|
Liu D, Cao F, Xu Z, Zhao C, Liu Z, Pang J, Liu ZX, Moghiseh M, Butler A, Liang S, Fan W, Yang J. Selective Organ-Targeting Hafnium Oxide Nanoparticles with Multienzyme-Mimetic Activities Attenuate Radiation-Induced Tissue Damage. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2308098. [PMID: 37777858 DOI: 10.1002/adma.202308098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 09/25/2023] [Indexed: 10/02/2023]
Abstract
Radioprotective agents hold clinical promises to counteract off-target adverse effects of radiation and benefit radiotherapeutic outcomes, yet the inability to control drug transport in human organs poses a leading limitation. Based upon a validated rank-based multigene signature model, radiosensitivity indices are evaluated of diverse normal organs as a genomic predictor of radiation susceptibility. Selective ORgan-Targeting (SORT) hafnium oxide nanoparticles (HfO2 NPs) are rationally designed via modulated synthesis by α-lactalbumin, homing to top vulnerable organs. HfO2 NPs like Hensify are commonly radioenhancers, but SORT HfO2 NPs exhibit surprising radioprotective effects dictated by unfolded ligands and Hf(0)/Hf(IV) redox couples. Still, the X-ray attenuation patterns allow radiological confirmation in target organs by dual-beam spectral computed tomography. SORT HfO2 NPs present potent antioxidant activities, catalytically scavenge reactive oxygen species, and mimic multienzyme catalytic activities. Consequently, SORT NPs rescue radiation-induced DNA damage in mouse and rabbit models and provide survival benefits upon lethal exposures. In addition to inhibiting radiation-induced mitochondrial apoptosis, SORT NPs impede DNA damage and inflammation by attenuating activated FoxO, Hippo, TNF, and MAPK interactive cascades. A universal methodology is proposed to reverse radioenhancers into radioprotectors. SORT radioprotective agents with image guidance are envisioned as compelling in personalized shielding from radiation deposition.
Collapse
Affiliation(s)
- Dingxin Liu
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
- Department of Intensive Care Unit, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Fei Cao
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
- Department of Minimally Invasive Interventional Therapy, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Zhifeng Xu
- Department of Radiology, The First People's Hospital of Foshan, Foshan, 528041, China
| | - Chunhua Zhao
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Zekun Liu
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Jiadong Pang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Ze-Xian Liu
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Mahdieh Moghiseh
- Department of Radiology, Centre for Bioengineering and Nanomedicine, University of Otago, Christchurch, 8011, New Zealand
- MARS Bioimaging Ltd., Christchurch, 8041, New Zealand
| | - Anthony Butler
- Department of Radiology, Centre for Bioengineering and Nanomedicine, University of Otago, Christchurch, 8011, New Zealand
- MARS Bioimaging Ltd., Christchurch, 8041, New Zealand
- Department of Physics and Astronomy, University of Canterbury, Christchurch, 8041, New Zealand
| | | | - Weijun Fan
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
- Department of Minimally Invasive Interventional Therapy, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| | - Jiang Yang
- State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, Guangzhou, 510060, China
| |
Collapse
|
6
|
Skrodzki D, Molinaro M, Brown R, Moitra P, Pan D. Synthesis and Bioapplication of Emerging Nanomaterials of Hafnium. ACS NANO 2024; 18:1289-1324. [PMID: 38166377 DOI: 10.1021/acsnano.3c08917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
A significant amount of progress in nanotechnology has been made due to the development of engineered nanoparticles. The use of metallic nanoparticles for various biomedical applications has been extensively investigated. Biomedical research is highly focused on them because of their inert nature, nanoscale structure, and similar size to many biological molecules. The intrinsic characteristics of these particles, including electronic, optical, physicochemical, and surface plasmon resonance, that can be altered by altering their size, shape, environment, aspect ratio, ease of synthesis, and functionalization properties, have led to numerous biomedical applications. Targeted drug delivery, sensing, photothermal and photodynamic therapy, and imaging are some of these. The promising clinical results of NBTXR3, a high-Z radiosensitizing nanomaterial derived from hafnium, have demonstrated translational potential of this metal. This radiosensitization approach leverages the dependence of energy attenuation on atomic number to enhance energy-matter interactions conducive to radiation therapy. High-Z nanoparticle localization in tumor issue differentially increases the effect of ionizing radiation on cancer cells versus nearby healthy ones and mitigates adverse effects by reducing the overall radiation burden. This principle enables material multifunctionality as contrast agents in X-ray-based imaging. The physiochemical properties of hafnium (Z = 72) are particularly advantageous for these applications. A well-placed K-edge absorption energy and high mass attenuation coefficient compared to elements in human tissue across clinical energy ranges leads to significant attenuation. Chemical reactivity allows for variety in nanoparticle synthesis, composition, and functionalization. Nanoparticles such as hafnium oxide exhibit excellent biocompatibility due to physiochemical inertness prior to incidence with ionizing radiation. Additionally, the optical and electronic properties are applicable in biosensing, optical component coatings, and semiconductors. The wide interest has prompted extensive research in design and synthesis to facilitate property fine-tuning. This review summarizes synthetic methods for hafnium-based nanomaterials and applications in therapy, imaging, and biosensing with a mechanistic focus. A discussion and future perspective section highlights clinical progress and elaborates on current challenges. By focusing on factors impacting applicational effectiveness and examining limitations this review aims to support researchers and expedite clinical translation of future hafnium-based nanomedicine.
Collapse
Affiliation(s)
- David Skrodzki
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Matthew Molinaro
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Richard Brown
- Department of Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Parikshit Moitra
- Department of Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Dipanjan Pan
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Department of Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Huck Institutes of the Life Sciences, 101 Huck Life Sciences Building, University Park, Pennsylvania 16802, United States
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
7
|
Meng X, Gao J, Sun Y, Duan F, Chen B, Lv G, Li H, Jiang X, Wu Y, Zhang J, Fang X, Yao Z, Zuo C, Bu W. Fusing Positive and Negative CT Contrast Nanoagent for the Sensitive Detection of Hepatoma. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2304668. [PMID: 37870166 PMCID: PMC10700169 DOI: 10.1002/advs.202304668] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 10/04/2023] [Indexed: 10/24/2023]
Abstract
Positive computed tomography (CT) contrast nanoagent has significant applications in diagnosing tumors. However, the sensitive differentiation between hepatoma and normal liver tissue remains challenging. This challenge arises primarily because both normal liver and hepatoma tissues capture the nanoagent, resulting in similar positive CT contrasts. Here, a strategy for fusing positive and negative CT contrast nanoagent is proposed to detect hepatoma. A nanoagent Hf-MOF@AB@PVP initially generates a positive CT contrast signal of 120.3 HU in the liver. Subsequently, it can specifically respond to the acidic microenvironment of hepatoma to generate H2 , further achieving a negative contrast of -96.0 HU. More importantly, the relative position between the negative and positive signals area is helpful to determine the location of hepatoma and normal liver tissues. The distinct contrast difference of 216.3 HU and relative orientation between normal liver and tumor tissues are meaningful to sensitively distinguish hepatoma from normal liver tissue utilizing CT imaging.
Collapse
Affiliation(s)
- Xianfu Meng
- Department of Nuclear MedicineChanghai HospitalNavy Medical UniversityShanghai200433China
- Department of Materials Science and State Key Laboratory of Molecular Engineering of PolymersAcademy for Engineering and TechnologyFudan UniversityShanghai200433China
| | - Jiahao Gao
- Department of RadiologyHuashan HospitalFudan UniversityShanghai200040China
| | - Yanhong Sun
- Department of Materials Science and State Key Laboratory of Molecular Engineering of PolymersAcademy for Engineering and TechnologyFudan UniversityShanghai200433China
- Department of GastroenterologyChanghai HospitalNaval Medical UniversityShanghai200433China
| | - Fei Duan
- Department of RadiologyEye & ENT Hospital of Fudan UniversityFudan UniversityShanghai200031China
| | - Bixue Chen
- Department of RadiologyWuxi People's HospitalNanjing Medical UniversityWuxi214023China
| | - Guanglei Lv
- Center for Biotechnology and Biomedical EngineeringYiwu Research Institute of Fudan UniversityYiwu322000China
| | - Huiyan Li
- Department of Materials Science and State Key Laboratory of Molecular Engineering of PolymersAcademy for Engineering and TechnologyFudan UniversityShanghai200433China
| | - Xingwu Jiang
- Department of Materials Science and State Key Laboratory of Molecular Engineering of PolymersAcademy for Engineering and TechnologyFudan UniversityShanghai200433China
| | - Yelin Wu
- Tongji University Cancer CenterShanghai Tenth People's HospitalTongji University School of MedicineShanghai200072China
| | - Jiawen Zhang
- Department of RadiologyHuashan HospitalFudan UniversityShanghai200040China
| | - Xiangming Fang
- Department of RadiologyWuxi People's HospitalNanjing Medical UniversityWuxi214023China
| | - Zhenwei Yao
- Department of RadiologyHuashan HospitalFudan UniversityShanghai200040China
| | - Changjing Zuo
- Department of Nuclear MedicineChanghai HospitalNavy Medical UniversityShanghai200433China
| | - Wenbo Bu
- Department of Materials Science and State Key Laboratory of Molecular Engineering of PolymersAcademy for Engineering and TechnologyFudan UniversityShanghai200433China
- Department of RadiologyHuashan HospitalFudan UniversityShanghai200040China
| |
Collapse
|
8
|
Wang J, Pan J, Tang Y, Chen J, Fei X, Xue W, Liu X. Advances of hafnium based nanomaterials for cancer theranostics. Front Chem 2023; 11:1283924. [PMID: 38075497 PMCID: PMC10704140 DOI: 10.3389/fchem.2023.1283924] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Accepted: 11/14/2023] [Indexed: 12/22/2024] Open
Abstract
Hafnium-based nanomaterials (Hf-NMs) have attracted the interest of numerous biomedical researchers by their unique properties. Recent years have witnessed significant advancements in the field of Hafnium-based nanomaterials, particularly in the context of cancer diagnosis and treatment. However, research in this area, especially concerning the clinical application of Hafnium-based nanomaterials, has not been thoroughly reviewed. This review will cover: 1) Classification and synthesis of Hafnium-based nanomaterials including Hafnium oxide nanomaterials, Hafnium Metal-Organic Frameworks/nanoscale coordination polymers (MOFs/NCPs); 2) Hafnium-based nanomaterials act as contrast enhancement agent for cancer imaging, and hafnium-based nanomaterials used for diagnosis in cancer liquid biopsy; 3) hafnium-based nanomaterials for cancer therapy, including hafnium-based nanomaterials for radiotherapy, hafnium-based nanomaterials for photodynamic therapy, hafnium-based nanomaterials for various combined therapy; and 4) Translation, toxicity, and safety for Hf-NMs in human and preclinical animal models. More attention will be given to the clinical translation of Hf-NMs in cancer.
Collapse
Affiliation(s)
- Jiayi Wang
- Department of Urology and Institute of Molecular Medicine (IMM), Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jiahua Pan
- Department of Urology and Institute of Molecular Medicine (IMM), Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yijun Tang
- Department of Endocrinology and Metabolism, Shanghai Children’s Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jingqi Chen
- Department of Urology and Institute of Molecular Medicine (IMM), Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xiaochen Fei
- Department of Urology and Institute of Molecular Medicine (IMM), Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Wei Xue
- Department of Urology and Institute of Molecular Medicine (IMM), Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xueliang Liu
- Department of Urology and Institute of Molecular Medicine (IMM), Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
9
|
Ding S, Chen L, Liao J, Huo Q, Wang Q, Tian G, Yin W. Harnessing Hafnium-Based Nanomaterials for Cancer Diagnosis and Therapy. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2300341. [PMID: 37029564 DOI: 10.1002/smll.202300341] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 03/01/2023] [Indexed: 06/19/2023]
Abstract
With the rapid development of nanotechnology and nanomedicine, there are great interests in employing nanomaterials to improve the efficiency of disease diagnosis and treatment. The clinical translation of hafnium oxide (HfO2 ), commercially namedas NBTXR3, as a new kind of nanoradiosensitizer for radiotherapy (RT) of cancers has aroused extensive interest in researches on Hf-based nanomaterials for biomedical application. In the past 20 years, Hf-based nanomaterials have emerged as potential and important nanomedicine for computed tomography (CT)-involved bioimaging and RT-associated cancer treatment due to their excellent electronic structures and intrinsic physiochemical properties. In this review, a bibliometric analysis method is employed to summarize the progress on the synthesis technology of various Hf-based nanomaterials, including HfO2 , HfO2 -based compounds, and Hf-organic ligand coordination hybrids, such as metal-organic frameworks or nanoscaled coordination polymers. Moreover, current states in the application of Hf-based CT-involved contrasts for tissue imaging or cancer diagnosis are reviewed in detail. Importantly, the recent advances in Hf-based nanomaterials-mediated radiosensitization and synergistic RT with other current mainstream treatments are also generalized. Finally, current challenges and future perspectives of Hf-based nanomaterials with a view to maximize their great potential in the research of translational medicine are also discussed.
Collapse
Affiliation(s)
- Shuaishuai Ding
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
- Institute of Pathology and Southwest Cancer Center, Key Laboratory of Tumor Immunopathology, Ministry of Education of China, The First Affiliated Hospital, Third Military Medical University (Army Medical University), Chongqing, 400038, P. R. China
| | - Lei Chen
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
| | - Jing Liao
- Institute of Pathology and Southwest Cancer Center, Key Laboratory of Tumor Immunopathology, Ministry of Education of China, The First Affiliated Hospital, Third Military Medical University (Army Medical University), Chongqing, 400038, P. R. China
- Laboratory for Micro-sized Functional Materials, Department of Chemistry and College of Elementary Education, Capital Normal University, Beijing, 100048, P. R. China
| | - Qing Huo
- College of Biochemical and Engineering, Beijing Union University, Beijing, 100023, China
| | - Qiang Wang
- Laboratory for Micro-sized Functional Materials, Department of Chemistry and College of Elementary Education, Capital Normal University, Beijing, 100048, P. R. China
| | - Gan Tian
- Institute of Pathology and Southwest Cancer Center, Key Laboratory of Tumor Immunopathology, Ministry of Education of China, The First Affiliated Hospital, Third Military Medical University (Army Medical University), Chongqing, 400038, P. R. China
- Chongqing Institute of Advanced Pathology, Jinfeng Laboratory, Chongqing, 401329, P. R. China
| | - Wenyan Yin
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, 100049, P. R. China
| |
Collapse
|
10
|
Jost G, McDermott M, Gutjahr R, Nowak T, Schmidt B, Pietsch H. New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT. Invest Radiol 2023; 58:515-522. [PMID: 37068840 PMCID: PMC10259215 DOI: 10.1097/rli.0000000000000978] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 03/01/2023] [Indexed: 04/19/2023]
Abstract
ABSTRACT The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task.A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role.The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included.Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.
Collapse
Affiliation(s)
- Gregor Jost
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| | - Michael McDermott
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Ralf Gutjahr
- Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | - Tristan Nowak
- Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | | | - Hubertus Pietsch
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| |
Collapse
|
11
|
Sawall S. [New contrast agents for photon-counting computed tomography]. RADIOLOGIE (HEIDELBERG, GERMANY) 2023:10.1007/s00117-023-01135-6. [PMID: 37069237 DOI: 10.1007/s00117-023-01135-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/03/2023] [Indexed: 04/19/2023]
Abstract
BACKGROUND The introduction of energy-selective photon-counting detectors into clinical practice represents the next milestone in computed tomography (CT). In addition to significantly higher resolution, these detectors allow the implicit acquisition of dual or multispectral data in a single measurement through the use of typically freely selectable thresholds. This capability reignited the interest in new contrast agents based on heavy elements, so-called high‑z elements, for clinical CT. OBJECTIVE The present article aims to investigate the potential suitability of different chemical elements as contrast agents and to discuss possible clinical applications, for example, K‑edge imaging or simultaneous application of different contrast agents. CONCLUSION First preclinical experiments as well as experiments in large animals could demonstrate potential advantages of contrast agents based on heavy elements. For example, such contrast agents promise a significant increase in image contrast compared to conventional iodine-based agents.
Collapse
Affiliation(s)
- Stefan Sawall
- Röntgenbildgebung und CT (E025), Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Deutschland.
- Medizinische Fakultät, Universität Heidelberg, Heidelberg, Deutschland.
| |
Collapse
|
12
|
Figueiredo AQ, Rodrigues CF, Fernandes N, de Melo-Diogo D, Correia IJ, Moreira AF. Metal-Polymer Nanoconjugates Application in Cancer Imaging and Therapy. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:3166. [PMID: 36144953 PMCID: PMC9503975 DOI: 10.3390/nano12183166] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 09/08/2022] [Accepted: 09/09/2022] [Indexed: 06/16/2023]
Abstract
Metallic-based nanoparticles present a unique set of physicochemical properties that support their application in different fields, such as electronics, medical diagnostics, and therapeutics. Particularly, in cancer therapy, the plasmonic resonance, magnetic behavior, X-ray attenuation, and radical oxygen species generation capacity displayed by metallic nanoparticles make them highly promising theragnostic solutions. Nevertheless, metallic-based nanoparticles are often associated with some toxicological issues, lack of colloidal stability, and establishment of off-target interactions. Therefore, researchers have been exploiting the combination of metallic nanoparticles with other materials, inorganic (e.g., silica) and/or organic (e.g., polymers). In terms of biological performance, metal-polymer conjugation can be advantageous for improving biocompatibility, colloidal stability, and tumor specificity. In this review, the application of metallic-polymer nanoconjugates/nanohybrids as a multifunctional all-in-one solution for cancer therapy will be summarized, focusing on the physicochemical properties that make metallic nanomaterials capable of acting as imaging and/or therapeutic agents. Then, an overview of the main advantages of metal-polymer conjugation as well as the most common structural arrangements will be provided. Moreover, the application of metallic-polymer nanoconjugates/nanohybrids made of gold, iron, copper, and other metals in cancer therapy will be discussed, in addition to an outlook of the current solution in clinical trials.
Collapse
Affiliation(s)
- André Q. Figueiredo
- CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, Av. Infante D. Henrique, 6200-506 Covilhã, Portugal
| | - Carolina F. Rodrigues
- CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, Av. Infante D. Henrique, 6200-506 Covilhã, Portugal
| | - Natanael Fernandes
- CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, Av. Infante D. Henrique, 6200-506 Covilhã, Portugal
| | - Duarte de Melo-Diogo
- CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, Av. Infante D. Henrique, 6200-506 Covilhã, Portugal
| | - Ilídio J. Correia
- CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, Av. Infante D. Henrique, 6200-506 Covilhã, Portugal
| | - André F. Moreira
- CICS-UBI—Health Sciences Research Centre, Universidade da Beira Interior, Av. Infante D. Henrique, 6200-506 Covilhã, Portugal
- CPIRN-UDI/IPG—Centro de Potencial e Inovação em Recursos Naturais, Unidade de Investigação para o Desenvolvimento do Interior do Instituto Politécnico da Guarda, Avenida Dr. Francisco de Sá Carneiro, No. 50, 6300-559 Guarda, Portugal
| |
Collapse
|
13
|
Dai G, Zhang Y, Wang X, Wang X, Jia J, Jia F, Yang L, Yang C. Small-Molecule Bi-DOTA Complex for High-Performance CT and Spectral CT Bioimaging. Front Oncol 2022; 12:813955. [PMID: 35251983 PMCID: PMC8894608 DOI: 10.3389/fonc.2022.813955] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 01/27/2022] [Indexed: 11/23/2022] Open
Abstract
Objectives It is necessary to develop a high-performance and biocompatible contrast agent to accurately diagnose various diseases via in vivo computed tomography (CT) imaging. Here, we synthesized a small molecular Bi-DOTA complex as a high-performance contrast agent for in vitro and in vivo CT bioimaging. Materials and Methods In our study, Bi-DOTA was fabricated through a facile and one-pot synthesis strategy. The formed Bi-DOTA complex was characterized via different techniques. Furthermore, Bi-DOTA was used for in vitro and in vivo CT bioimaging to verify its X-ray attenuation ability, especially in vivo kidney imaging, gastrointestinal tract CT imaging, and spectral CT imaging. Results A small molecular Bi-DOTA complex with a molecular mass of 0.61 kDa was synthesized successfully, which exhibited outstanding dispersion, good biocompatibility, and superior X-ray attenuation ability. Meanwhile, we showed that the obtained contrast agent was quite biocompatible and safe in the given concentration range as confirmed by in vitro and in vivo cytotoxicity assay. Also, the proposed contrast agent can be rapidly excreted from the body via the urinary system, avoiding the potential side effects caused by long-term retention in vivo. Importantly, Bi-DOTA was successfully used in high-quality in vitro CT imaging, in vivo kidney imaging, gastrointestinal tract CT imaging, and spectral CT imaging. Conclusions These superiorities allowed Bi-DOTA to be used as an efficient CT contrast agent and laid down a new way of designing high-performance CT contrast agents with great clinical transformation potential.
Collapse
Affiliation(s)
- Guidong Dai
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| | - Yu Zhang
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
| | - Ximei Wang
- Department of Medical Imaging, Southwest Medical University, Luzhou, China
| | - Xingyu Wang
- Department of Medical Imaging, Southwest Medical University, Luzhou, China
| | - Juan Jia
- Department of Medical Imaging, Southwest Medical University, Luzhou, China
| | - Fei Jia
- Department of Medical Imaging, Southwest Medical University, Luzhou, China
| | - Lu Yang
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
- *Correspondence: Lu Yang, ; Chunmei Yang,
| | - Chunmei Yang
- Department of Radiology, The Affiliated Hospital of Southwest Medical University, Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province, Luzhou, China
- *Correspondence: Lu Yang, ; Chunmei Yang,
| |
Collapse
|
14
|
Sneha KR, Sailaja GS. Intrinsically radiopaque biomaterial assortments: a short review on the physical principles, X-ray imageability, and state-of-the-art developments. J Mater Chem B 2021; 9:8569-8593. [PMID: 34585717 DOI: 10.1039/d1tb01513c] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
X-ray attenuation ability, otherwise known as radiopacity of a material, could be indisputably tagged as the central and decisive parameter that produces contrast in an X-ray image. Radiopaque biomaterials are vital in the healthcare sector that helps clinicians to track them unambiguously during pre and post interventional radiological procedures. Medical imaging is one of the most powerful resources in the diagnostic sector that aids improved treatment outcomes for patients. Intrinsically radiopaque biomaterials enable themselves for visual targeting/positioning as well as to monitor their fate and further provide the radiologists with critical insights about the surgical site. Moreover, the emergence of advanced real-time imaging modalities is a boon to the contemporary healthcare systems that allow to perform minimally invasive surgical procedures and thereby reduce the healthcare costs and minimize patient trauma. X-ray based imaging is one such technologically upgraded diagnostic tool with many variants like digital X-ray, computed tomography, digital subtraction angiography, and fluoroscopy. In light of these facts, this review is aimed to briefly consolidate the physical principles of X-ray attenuation by a radiopaque material, measurement of radiopacity, classification of radiopaque biomaterials, and their recent advanced applications.
Collapse
Affiliation(s)
- K R Sneha
- Department of Polymer Science and Rubber Technology, Cochin University of Science and Technology, Kochi - 682022, India.
| | - G S Sailaja
- Department of Polymer Science and Rubber Technology, Cochin University of Science and Technology, Kochi - 682022, India. .,Interuniversity Centre for Nanomaterials and Devices, CUSAT, Kochi - 682022, India.,Centre for Advanced Materials, CUSAT, Kochi - 682022, India
| |
Collapse
|
15
|
Sartoretti T, Eberhard M, Nowak T, Gutjahr R, Jost G, Pietsch H, Schmidt B, Flohr T, Alkadhi H, Euler A. Photon-Counting Multienergy Computed Tomography With Spectrally Optimized Contrast Media for Plaque Removal and Stenosis Assessment. Invest Radiol 2021; 56:563-570. [PMID: 33660630 DOI: 10.1097/rli.0000000000000773] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The aim of this study was to systematically evaluate the potential to combine investigational contrast media with spectrally optimized energy-thresholding of photon-counting detector computed tomography (PCCT) for subtraction of calcified plaques in a coronary artery stenosis phantom. METHODS A small vessel phantom containing 3 fillable tubes (diameter, 3 mm each) with calcified plaques was placed into an anthropomorphic chest phantom. The plaques had incremental thicknesses ranging from 0.3 to 2.7 mm, simulating vessel stenoses ranging from 10% to 90% of the lumen diameter. The phantom was filled with 5 different investigational contrast media (iodine, bismuth, hafnium, holmium, and tungsten) at equal mass concentrations (15 mg/mL) and was imaged on a prototype PCCT at 140 kVp using optimized, contrast media-dependent energy thresholds. Contrast maps (CMs) were reconstructed for each contrast medium by applying a linear 2-material decomposition algorithm. Image noise magnitude and noise texture of CM were compared among the contrast media using the noise power spectrum. Two blinded readers independently rated the vessel lumen visualization on short-axis and the overall subjective image quality on long-axis CM relative to iodine as the reference standard. Four readers determined the highest degree of stenosis that could be assessed with high diagnostic confidence on long-axis CM. RESULTS Average image noise on CM was lower for tungsten (49 HU) and hafnium (62 HU) and higher for bismuth (81 HU) and holmium (165 HU) compared with iodine (78 HU). Noise texture of CM was similar among the contrast media. Interreader agreement for vessel lumen visualization on short-axis CM ranged from moderate to excellent (k = 0.567-0.814). Compared with iodine, lumen visualization of each reader was improved using tungsten (P < 0.001 for both readers), similar to improved using hafnium (P = 0.008, P = 0.29), similar using bismuth (P = 0.38, P = 0.69), and decreased using holmium (both, P < 0.001). Overall subjective image quality was similar for holmium and superior for tungsten, hafnium, and bismuth as compared with iodine. Higher-degree stenoses were evaluable with high confidence using tungsten (mean, 70%; interquartile range, 70%-70%), bismuth (70%; 60%-70%), and hafnium (75%; 70%-80%) compared with iodine (50%; 50%-60%) and holmium (50%; 50%-60%). CONCLUSIONS Spectral optimization in PCCT combined with investigational contrast media can improve calcium subtraction and stenosis assessment in small vessels. Contrast maps of tungsten and, to a lesser extent, hafnium as contrast media yielded superior image noise properties and improved vessel lumen visualization, along with a higher subjective image quality compared with the reference standard iodine.
Collapse
Affiliation(s)
- Thomas Sartoretti
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | | | | | | | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
16
|
Shulyak AT, Bortnikov EO, Kubasov AS, Selivanov NA, Lipengolts AA, Zhdanov AP, Bykov AY, Zhizhin KY, Kuznetsov NT. Synthesis of Hafnium(IV) Polyaminoacetates. Molecules 2021; 26:molecules26123725. [PMID: 34207280 PMCID: PMC8234123 DOI: 10.3390/molecules26123725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/08/2021] [Accepted: 06/12/2021] [Indexed: 11/16/2022] Open
Abstract
The interaction of hafnium(IV) salts (oxide-dichloride, chloride, and bromide) with nitrilotriacetic acid (NTA), diethylenetriamminepentaacetic acid (DTPA), 1,2-diaminocyclohexanetetraacetic acid (CDTA), 1,3-dipropylmino-2-hydroxy N,N,N',N'-tetraacetic acid (dpta), and N-(2-hydroxyethyl)ethylenediamine triacetic acid (HEDTA) has been studied. The corresponding complexes Na2[Hf(NTA)2]·3H2O (1), Na[HfDTPA]·3H2O (2), [HfCDTA(H2O)2] (3), and Na[Hf2(dpta)2]·7.5H2O·0.5C2H5OH (4) have been isolated and characterized and their structures have been determined by single crystal X-ray diffraction. Biological studies of [HfCDTA(H2O)2] have shown that in 5% glucose solution this complex has low toxicity and good contrasting ability.
Collapse
Affiliation(s)
- Alexandra T. Shulyak
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
- Inorganic Chemistry Department, Lomonosov Institute of Fine Chemical Technologies, MIREA-Russian Technological University, pr. Vernadskogo, 86, 119454 Moscow, Russia
- Correspondence: ; Tel.: +7-(916)-823-01-57
| | - Evgeniy O. Bortnikov
- Organic Chemistry Department, Weizmann Institute of Science, 234 Herzl Street, Rehovot 7610001, Israel;
| | - Alexey S. Kubasov
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
| | - Nikita A. Selivanov
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
| | - Alexey A. Lipengolts
- N.N. Blokhin National Medical Research Center of Oncology, Federal State Budgetary Institution, Ministry of Health of the Russian Federation (N.N. Blokhin NMRCO), Kashirskoye Shosse 24, 115478 Moscow, Russia;
| | - Andrey P. Zhdanov
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
| | - Alexander Yu. Bykov
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
| | - Konstantin Yu. Zhizhin
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
| | - Nikolai T. Kuznetsov
- Kurnakov Institute of General and Inorganic Chemistry, Russian Academy of Sciences, Leninskiy pr. 31, 119991 Moscow, Russia; (A.S.K.); (N.A.S.); (A.P.Z.); (A.Y.B.); (K.Y.Z.); (N.T.K.)
| |
Collapse
|
17
|
Sawall S, Amato C, Klein L, Wehrse E, Maier J, Kachelrieß M. Toward molecular imaging using spectral photon-counting computed tomography? Curr Opin Chem Biol 2021; 63:163-170. [PMID: 34051510 DOI: 10.1016/j.cbpa.2021.04.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 04/07/2021] [Indexed: 12/22/2022]
Abstract
Molecular imaging is a valuable tool in drug discovery and development, early screening and diagnosis of diseases, and therapy assessment among others. Although many different imaging modalities are in use today, molecular imaging with computed tomography (CT) is still challenging owing to its low sensitivity and soft tissue contrast compared with other modalities. Recent technical advances, particularly the introduction of spectral photon-counting detectors, might allow overcoming these challenges. Herein, the fundamentals and recent advances in CT relevant to molecular imaging are reviewed and potential future preclinical and clinical applications are highlighted. The review concludes with a discussion of potential future advancements of CT for molecular imaging.
Collapse
Affiliation(s)
- Stefan Sawall
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany.
| | - Carlo Amato
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Laura Klein
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Physical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 226, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Eckhard Wehrse
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Joscha Maier
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Marc Kachelrieß
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany
| |
Collapse
|
18
|
McGinnity TL, Sokolova V, Prymak O, Nallathamby PD, Epple M, Roeder RK. Colloidal stability, cytotoxicity, and cellular uptake of HfO 2 nanoparticles. J Biomed Mater Res B Appl Biomater 2021; 109:1407-1417. [PMID: 33474824 DOI: 10.1002/jbm.b.34800] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 12/16/2020] [Accepted: 01/09/2021] [Indexed: 12/23/2022]
Abstract
The colloidal stability, cytotoxicity, and cellular uptake of hafnium oxide (HfO2 ) nanoparticles (NPs) were investigated in vitro to assess safety and efficacy for use as a deliverable theranostic in nanomedicine. Monoclinic HfO2 NPs, ~60-90 nm in diameter and ellipsoidal in shape, were directly prepared without calcination by a hydrothermal synthesis at 83% yield. The as-prepared, bare HfO2 NPs exhibited colloidal stability in cell culture media for at least 10 days without significant agglomeration or settling. The viability (live/dead assay) of human epithelial cells (HeLa) and monocyte-derived macrophages (THP-1) did not fall below 95% of untreated cells after up to 24 h exposure to HfO2 NPs at concentrations up to 0.80 mg/ml. Similarly, the mitochondrial activity (MTT assay) of HeLa and THP-1 cells did not fall below 80% of untreated cells after up to 24 h exposure to HfO2 NPs at concentrations up to 0.40 mg/ml. Cellular uptake was confirmed and visualized in both HeLa and THP-1 cells by fluorescence microscopy of HfO2 NPs labeled with Cy5 and transmission electron microscopy (TEM) of bare HfO2 NPs. TEM micrographs provided direct observation of macropinocytosis and endosomal compartmentalization within 4 h of exposure. Thus, the HfO2 NPs in this study exhibited colloidal stability, cytocompatibility, and cellular uptake for potential use as a deliverable theranostic in nanomedicine.
Collapse
Affiliation(s)
- Tracie L McGinnity
- Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana, USA.,Harper Cancer Research Institute, University of Notre Dame, Notre Dame, Indiana, USA
| | - Viktoriya Sokolova
- Inorganic Chemistry and Center for Nanointegration Duisburg-Essen (CeNIDE), University of Duisburg-Essen, Essen, Germany
| | - Oleg Prymak
- Inorganic Chemistry and Center for Nanointegration Duisburg-Essen (CeNIDE), University of Duisburg-Essen, Essen, Germany
| | - Prakash D Nallathamby
- Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana, USA.,Harper Cancer Research Institute, University of Notre Dame, Notre Dame, Indiana, USA
| | - Matthias Epple
- Inorganic Chemistry and Center for Nanointegration Duisburg-Essen (CeNIDE), University of Duisburg-Essen, Essen, Germany
| | - Ryan K Roeder
- Department of Aerospace and Mechanical Engineering, Bioengineering Graduate Program, University of Notre Dame, Notre Dame, Indiana, USA.,Harper Cancer Research Institute, University of Notre Dame, Notre Dame, Indiana, USA
| |
Collapse
|
19
|
Ma S, Wang L, Liu Z, Luo X, Zhou Z, Xie J, Li Y, Cong S, Zhou M, Xu Y, Ran G. "One stone, two birds": engineering 2-D ultrathin heterostructure nanosheet BiNS@NaLnF 4 for dual-modal computed tomography/magnetic resonance imaging guided, photonic synergetic theranostics. NANOSCALE 2021; 13:185-194. [PMID: 33325961 DOI: 10.1039/d0nr07590f] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
It is interesting yet challenging to design theranostic nanoplatforms for the accurate diagnosis and therapy of diseases; these nanoplatforms consist of single contrast-enhanced imaging or therapeutic agents, and they possess their own unique shortcomings that limit their widespread bio-medical applications. Therefore, designing a potential theranostic agent is an emerging approach for the synergistic diagnosis and therapeutics in bio-medical applications. Herein, a lanthanide-loaded (NaLnF4) heterostructure BiOCl ultrathin nanosheet (BiNS@NaLnF4) as a theranostic agent was synthesized facilely by a solvothermal protocol. BiNS@NaLnF4 was employed as a multi-modal contrast agent for computed tomography (CT) and magnetic resonance imaging (MRI), showing a high-performance X-ray absorption contrast effect, an outstanding T1-weighted imaging function result, good cytocompatibility and favorable in vivo effective imaging for CT. Notably, BiNS@NaLnF4 was applied to achieve a satisfactory photon-thermal conversion efficiency (35.3%). Moreover, the special heterostructure barrier achieved increased utilization of electrons/holes, enhancing the generation of reactive oxygen species (ROS) under visible-light irradiation to further expand the therapeutic effect. Dramatically, visible light emission with the up-conversion law was employed to stimulate ROS after irradiation with a 980 nm laser. Simultaneously, the as-prepared BiNS@NaLnF4 can be applied in photothermal/photodynamic therapy (PTT/PDT) investigation for tumor ablation. In summary, the results reveal that BiNS@NaLnF4 is a potential multi-modal theranostic candidate, providing new insights for synergistic theranostics of tumors.
Collapse
Affiliation(s)
- Sihan Ma
- College of energy, Xiamen University, Xiamen City, Fujian Province 361002, China. and Fujian Research Center for Nuclear Engineering, Xiamen City, Fujian Province 361102, China
| | - Lin Wang
- School of Medicine, Xiamen University, Xiamen, Fujian 361002, China and Department of Oncology, Zhongshan Hospital, Xiamen University, No. 201-209 Hubinnan Road, Xiamen 361004, Fujian Province, China.
| | - Zongjunlin Liu
- School of Medicine, Xiamen University, Xiamen, Fujian 361002, China
| | - Xian Luo
- School of Medicine, Xiamen University, Xiamen, Fujian 361002, China
| | - Zonglang Zhou
- School of Medicine, Xiamen University, Xiamen, Fujian 361002, China and 174 Clinical College affiliated to Anhui Medical University, Anhui Medical University, Hefei, Anhui Province 230032, China
| | - Jun Xie
- School of Medicine, Xiamen University, Xiamen, Fujian 361002, China
| | - Yipeng Li
- College of energy, Xiamen University, Xiamen City, Fujian Province 361002, China. and Fujian Research Center for Nuclear Engineering, Xiamen City, Fujian Province 361102, China
| | - Shuo Cong
- College of energy, Xiamen University, Xiamen City, Fujian Province 361002, China. and Fujian Research Center for Nuclear Engineering, Xiamen City, Fujian Province 361102, China
| | - Min Zhou
- School of pharmaceutical sciences, Xiamen University, Xiamen City, Fujian Province 361002, China.
| | - Yang Xu
- School of pharmaceutical sciences, Xiamen University, Xiamen City, Fujian Province 361002, China.
| | - Guang Ran
- College of energy, Xiamen University, Xiamen City, Fujian Province 361002, China. and Fujian Research Center for Nuclear Engineering, Xiamen City, Fujian Province 361102, China
| |
Collapse
|
20
|
Bao J, Zu X, Wang X, Li J, Fan D, Shi Y, Xia Q, Cheng J. Multifunctional Hf/Mn-TCPP Metal-Organic Framework Nanoparticles for Triple-Modality Imaging-Guided PTT/RT Synergistic Cancer Therapy. Int J Nanomedicine 2020; 15:7687-7702. [PMID: 33116495 PMCID: PMC7550217 DOI: 10.2147/ijn.s267321] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Accepted: 09/21/2020] [Indexed: 11/23/2022] Open
Abstract
Background Recent studies have validated and confirmed the great potential of nanoscale metal-organic framework (NMOF) in the biomedical field, especially in improving the efficiency of cancer diagnosis and therapy. However, most previous studies only utilized either the metal cluster or the organic ligand of the NMOF for cancer treatments and merely reported limited theranostic functions, which may not be optimized. As a highly designable and easily functionalized material, prospective rational design offers a powerful way to extract the maximum benefit from NMOF for cancer theranostic applications. Materials and Methods A NMOF based on hafnium (Hf) cluster and Mn(III)-porphyrin ligand was rational designed and synthesized as a high-performance multifunctional theranostic agent. The folic acid (FA) was modified on the NMOF surface to enhance the cancer targeting efficacy. The proposed “all-in-one” FA-Hf-Mn-NMOF (fHMNM) was characterized and identified using various analytical techniques. Then, in vitro and in vivo studies were performed to further explore the effects of fHMNM both as the magnetic resonance imaging (MRI)/computed tomography (CT)/photoacoustic imaging (PAI) contrast agent and as the photothermal therapy (PTT)/radiotherapy (RT) agent. Results A tumour targeting multifunctional fHMNM was successfully synthesized with high performance for MRI/CT/PAI enhancements and image-guided PTT/RT synergistic therapy properties. Compared with the current clinical CT and MR contrast agents, the X-ray attenuation and T1 relaxation rate of this integrated nanosystem increased 1.7-fold and 3–5-fold, respectively. More importantly, the catalase-like Mn(III)-porphyrin ligand can decompose H2O2 into O2 in tumour microenvironments to improve the synergistic treatment efficiency of PTT and RT. Significant tumour growth inhibition was achieved in mouse cancer models without obvious damage to the other organs. Conclusion This work highlights the potential of fHMNM as an easily designable material for biomedical applications, could be an effective tool for in vivo detection and subsequent treatment of tumour.
Collapse
Affiliation(s)
- Jianfeng Bao
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, Henan, People's Republic of China.,College of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang, Henan, People's Republic of China
| | - Xiangyang Zu
- College of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang, Henan, People's Republic of China
| | - Xiao Wang
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, Henan, People's Republic of China
| | - Jinghua Li
- College of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang, Henan, People's Republic of China
| | - Dandan Fan
- Henan Institute of Medical and Pharmaceutical Sciences, Zhengzhou University, Zhengzhou, Henan, People's Republic of China
| | - Yupeng Shi
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, Henan, People's Republic of China
| | - Qingchun Xia
- Henan Key Laboratory of Boron Chemistry and Advanced Energy Materials, School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, Henan, People's Republic of China
| | - Jingliang Cheng
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou, Henan, People's Republic of China
| |
Collapse
|
21
|
Jacobsen MC, Thrower SL. Multi-energy computed tomography and material quantification: Current barriers and opportunities for advancement. Med Phys 2020; 47:3752-3771. [PMID: 32453879 PMCID: PMC8495770 DOI: 10.1002/mp.14241] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 04/20/2020] [Accepted: 05/07/2020] [Indexed: 12/21/2022] Open
Abstract
Computed tomography (CT) technology has rapidly evolved since its introduction in the 1970s. It is a highly important diagnostic tool for clinicians as demonstrated by the significant increase in utilization over several decades. However, much of the effort to develop and advance CT applications has been focused on improving visual sensitivity and reducing radiation dose. In comparison to these areas, improvements in quantitative CT have lagged behind. While this could be a consequence of the technological limitations of conventional CT, advanced dual-energy CT (DECT) and photon-counting detector CT (PCD-CT) offer new opportunities for quantitation. Routine use of DECT is becoming more widely available and PCD-CT is rapidly developing. This review covers efforts to address an unmet need for improved quantitative imaging to better characterize disease, identify biomarkers, and evaluate therapeutic response, with an emphasis on multi-energy CT applications. The review will primarily discuss applications that have utilized quantitative metrics using both conventional and DECT, such as bone mineral density measurement, evaluation of renal lesions, and diagnosis of fatty liver disease. Other topics that will be discussed include efforts to improve quantitative CT volumetry and radiomics. Finally, we will address the use of quantitative CT to enhance image-guided techniques for surgery, radiotherapy and interventions and provide unique opportunities for development of new contrast agents.
Collapse
Affiliation(s)
- Megan C. Jacobsen
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| | - Sara L. Thrower
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| |
Collapse
|
22
|
Schöckel L, Jost G, Seidensticker P, Lengsfeld P, Palkowitsch P, Pietsch H. Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography. Invest Radiol 2020; 55:592-597. [DOI: 10.1097/rli.0000000000000696] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
23
|
Hsu JC, Nieves LM, Betzer O, Sadan T, Noël PB, Popovtzer R, Cormode DP. Nanoparticle contrast agents for X-ray imaging applications. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2020; 12:e1642. [PMID: 32441050 DOI: 10.1002/wnan.1642] [Citation(s) in RCA: 78] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/13/2020] [Accepted: 04/14/2020] [Indexed: 12/12/2022]
Abstract
X-ray imaging is the most widely used diagnostic imaging method in modern medicine and several advanced forms of this technology have recently emerged. Iodinated molecules and barium sulfate suspensions are clinically approved X-ray contrast agents and are widely used. However, these existing contrast agents provide limited information, are suboptimal for new X-ray imaging techniques and are developing safety concerns. Thus, over the past 15 years, there has been a rapid growth in the development of nanoparticles as X-ray contrast agents. Nanoparticles have several desirable features such as high contrast payloads, the potential for long circulation times, and tunable physicochemical properties. Nanoparticles have also been used in a range of biomedical applications such as disease treatment, targeted imaging, and cell tracking. In this review, we discuss the principles behind X-ray contrast generation and introduce new types of X-ray imaging modalities, as well as potential elements and chemical compositions that are suitable for novel contrast agent development. We focus on the progress in nanoparticle X-ray contrast agents developed to be renally clearable, long circulating, theranostic, targeted, or for cell tracking. We feature agents that are used in conjunction with the newly developed multi-energy computed tomography and mammographic imaging technologies. Finally, we offer perspectives on current limitations and emerging research topics as well as expectations for the future development of the field. This article is categorized under: Diagnostic Tools > in vivo Nanodiagnostics and Imaging Nanotechnology Approaches to Biology > Nanoscale Systems in Biology.
Collapse
Affiliation(s)
- Jessica C Hsu
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, School of Engineering and Applied Science of the University of Pennsylvania, Pennsylvania, USA
| | - Lenitza M Nieves
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Biochemistry and Molecular Biophysics, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Oshra Betzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Tamar Sadan
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Rachela Popovtzer
- Faculty of Engineering and the Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - David P Cormode
- Department of Radiology, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, School of Engineering and Applied Science of the University of Pennsylvania, Pennsylvania, USA.,Department of Biochemistry and Molecular Biophysics, Perelman School of Medicine of the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
24
|
Mass attenuation coefficients, effective atomic numbers and electron densities of some contrast agents for computed tomography. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108507] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
25
|
Bi-DTPA as a high-performance CT contrast agent for in vivo imaging. Biomaterials 2019; 203:1-11. [PMID: 30844678 DOI: 10.1016/j.biomaterials.2019.03.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 02/22/2019] [Accepted: 03/01/2019] [Indexed: 01/07/2023]
Abstract
Clinically used iodinated computer tomography (CT) contrast agents suffer from low sensitivity, and the emerging lanthanide-chelates and CT imaging nanoagents raise great safety concerns. The fusion of high sensitivity and good biocompatibility is highly desired for the development of CT contrast agents. Herein, we propose a facile and green one-pot synthesis strategy for the fabrication of a small molecular CT contrast agent, Bi-diethylene triamine pentaacetate acid (DTPA) complex, for high-performance CT and spectral CT imaging. The Bi-DTPA exhibits yield of near 100%, outstanding water solubility, favorable biocompatibility, large-scale production capability, and superior X-ray attenuation ability, and is successfully applied in high-quality in vivo kidney imaging and gastrointestinal tract CT imaging and appealing spectral CT imaging. The proposed contrast agent can be rapidly excreted from body, avoiding the potential side effects caused by the long-term retention in vivo. Furthermore, our design shows great potential in developing diverse multifunctional contrast agents via chemical modification. The proposed Bi-DTPA with unique superiorities shows a bright prospect in clinic CT imaging, especially spectral CT imaging, and lays down a new way for the design of high-performance CT contrast agents with great clinical transformation potential.
Collapse
|
26
|
Deblonde GJP, Lohrey TD, Abergel RJ. Inducing selectivity and chirality in group IV metal coordination with high-denticity hydroxypyridinones. Dalton Trans 2019; 48:8238-8247. [PMID: 31094380 DOI: 10.1039/c9dt01031a] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The solution- and solid-state interactions between the octadentate siderophore mimic 3,4,3-LI(1,2-HOPO) (343HOPO) and group IV metal ions were investigated using high-resolution mass spectrometry, liquid chromatography, UV-visible spectrophotometry, metal-competition batch titrations, and single crystal X-ray diffraction. 343HOPO forms a neutral 1 : 1 complex, [HfIV343HOPO], that exhibits extreme stability in aqueous solution, with a log β110 value reaching 42.3. These results affirm the remarkable charge-based selectivity of 343HOPO for octacoordinated tetravalent cations with a Hf(iv) complex 1021 more stable than its Lu(iii) analogue. Moreover, [HfIV343HOPO] and its Zr(iv) counterpart show exceptional robustness, with the ligand remaining bound to the cation over a very broad pH range: from pH ∼ 11 to acidic conditions as strong as 10 M HCl. In stark contrast, Ti(iv)-343HOPO species are far less stable and undergo hydrolysis at pH as low as ∼6, likely due to the mismatch between the preferred hexacoordinated Ti(iv) ion and octadentate 343HOPO ligand. The extreme charge-based and denticity-driven selectivity of 343HOPO, now observed across the periodic table, paves the way for new selective sequestration systems for radionuclides including medical 44Ti, 89Zr or 177Lu/Hf isotopes, toxic polonium (Po) contaminants, as well as rutherfordium (Rf) research isotopes. Furthermore, despite the lack of a chiral center in 343HOPO, its complexes with metal ions are chiral and appear to form a single set of enantiomers.
Collapse
Affiliation(s)
- Gauthier J-P Deblonde
- Chemical Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | | | | |
Collapse
|
27
|
Zhang G, Naha PC, Gautam P, Cormode DP, Chan JMW. Water-Dispersible Bismuth-Organic Materials with Computed Tomography Contrast Properties. ACS APPLIED BIO MATERIALS 2018; 1:1918-1926. [PMID: 31396587 PMCID: PMC6687070 DOI: 10.1021/acsabm.8b00488] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Two bismuth-organic network polymers were synthesized by means of a one-step polycondensation reaction between an aromatic dithiol/trithiol and triphenylbismuth. The materials were characterized by solid-state UV-vis spectroscopy, Raman spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, powder X-ray diffraction, elemental microanalysis, and thermogravimetric analysis. Uniform dispersion of the hydrophobic and water-insoluble bismuth-containing polymers in aqueous media was achieved by the addition of 2 kDa poly(ethylene glycol) methyl ether thiol. This enabled quantitative phantom imaging experiments on a clinical computed tomography (CT) scanner, which showed that the coordination polymers possessed strong CT contrast properties. The observed X-ray attenuation properties of each coordination polymer were correlated with its bismuth payload. The X-ray opacity, thermal and chemical stabilities, and aqueous dispersibility of this novel class of bismuth-organic materials make them potentially useful as biomedical CT contrast agents and radiopaque materials.
Collapse
Affiliation(s)
- Guoxian Zhang
- Department of Chemistry and Biomolecular Sciences, University of Ottawa, 10 Marie Curie Pvt., Ottawa, Ontario K1N 6N5, Canada
| | - Pratap C. Naha
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Prabhat Gautam
- Department of Chemistry and Biomolecular Sciences, University of Ottawa, 10 Marie Curie Pvt., Ottawa, Ontario K1N 6N5, Canada
| | - David P. Cormode
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States
| | - Julian M. W. Chan
- Department of Chemistry and Biomolecular Sciences, University of Ottawa, 10 Marie Curie Pvt., Ottawa, Ontario K1N 6N5, Canada
| |
Collapse
|
28
|
Meenambal R, Kannan S. Cosubstitution of Lanthanides (Gd3+/Dy3+/Yb3+) in β-Ca3(PO4)2 for Upconversion Luminescence, CT/MRI Multimodal Imaging. ACS Biomater Sci Eng 2017; 4:47-56. [DOI: 10.1021/acsbiomaterials.7b00742] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Rugmani Meenambal
- Centre for Nanoscience and
Technology, Pondicherry University, R. V. Nagar, Kalapet, Puducherry 605 014, India
| | - S. Kannan
- Centre for Nanoscience and
Technology, Pondicherry University, R. V. Nagar, Kalapet, Puducherry 605 014, India
| |
Collapse
|