1
|
Ahmed KH, Zuria AM, Mohamedi M. Integration of Carbon Nanotubes into Manganese Dioxide Nanorods for Enhanced Enzymeless Electrochemical Glucose Sensing with High Sensitivity and Selectivity. BIOSENSORS 2025; 15:215. [PMID: 40277529 PMCID: PMC12025318 DOI: 10.3390/bios15040215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2024] [Revised: 03/23/2025] [Accepted: 03/25/2025] [Indexed: 04/26/2025]
Abstract
Freestanding electrode designs, cost-effective catalysts, and enhanced electrical conductivity are crucial for improving the performance of fourth-generation non-enzymatic glucose electrochemical sensors. These factors enable more efficient, scalable, and durable sensors with better sensitivity, stability, and affordability for real-time glucose monitoring. In this study, we explore a freestanding electrode design combining carbon nanotubes (CNTs) with MnO2 nanorods to enhance charge transfer, increase surface area, and optimize catalytic activity. This CNTs/MnO2 electrode demonstrates exceptional catalytic activity for glucose oxidation, achieving a high sensitivity of 309.73 µA cm-2 mM-1 within a linear range of 0.5 to 10 mM-well above typical physiological glucose levels (3-8 mM), with a detection limit of 0.19 mM at a signal-to-noise ratio of 3. The electrode also shows excellent durability and remarkable selectivity for glucose over common interferents like ascorbic acid and uric acid, as well as antifouling properties in the presence of KCl. These attributes are essential for accurate glucose detection in complex biological samples. The integration of MnO2 nanorods with CNTs in freestanding nanostructures opens up exciting opportunities for developing high-performance, robust electrochemical sensors for diverse applications.
Collapse
Affiliation(s)
| | | | - Mohamed Mohamedi
- Institut National de la Recherche Scientifique (INRS), Énergie Matériaux Télécommunications (EMT), 1650, Boulevard Lionel-Boulet, Varennes, QC J3X 1P7, Canada
| |
Collapse
|
2
|
Ahmed KH, Mohamedi M. Microfibrous Carbon Paper Decorated with High-Density Manganese Dioxide Nanorods: An Electrochemical Nonenzymatic Platform of Glucose Sensing. SENSORS (BASEL, SWITZERLAND) 2024; 24:5864. [PMID: 39338610 PMCID: PMC11435572 DOI: 10.3390/s24185864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2024] [Revised: 09/07/2024] [Accepted: 09/08/2024] [Indexed: 09/30/2024]
Abstract
Nanorod structures exhibit a high surface-to-volume ratio, enhancing the accessibility of electrolyte ions to the electrode surface and providing an abundance of active sites for improved electrochemical sensing performance. In this study, tetragonal α-MnO2 with a large K+-embedded tunnel structure, directly grown on microfibrous carbon paper to form densely packed nanorod arrays, is investigated as an electrocatalytic material for non-enzymatic glucose sensing. The MnO2 nanorods electrode demonstrates outstanding catalytic activity for glucose oxidation, showcasing a high sensitivity of 143.82 µA cm-2 mM-1 within the linear range from 0.01 to 15 mM, with a limit of detection (LOD) of 0.282 mM specifically for glucose molecules. Importantly, the MnO2 nanorods electrode exhibits excellent selectivity towards glucose over ascorbic acid and uric acid, which is crucial for accurate glucose detection in complex samples. For comparison, a gold electrode shows a lower sensitivity of 52.48 µA cm-2 mM-1 within a linear range from 1 to 10 mM. These findings underscore the superior performance of the MnO2 nanorods electrode in both sensitivity and selectivity, offering significant potential for advancing electrochemical sensors and bioanalytical techniques for glucose monitoring in physiological and clinical settings.
Collapse
Affiliation(s)
- Khawtar Hasan Ahmed
- Institut National de la Recherche Scientifique (INRS), Énergie Matériaux Télécommunications (EMT), 1650, Boulevard Lionel-Boulet, Varennes, QC J3X 1P7, Canada
| | - Mohamed Mohamedi
- Institut National de la Recherche Scientifique (INRS), Énergie Matériaux Télécommunications (EMT), 1650, Boulevard Lionel-Boulet, Varennes, QC J3X 1P7, Canada
| |
Collapse
|
3
|
Ren T, Yan L, Zhao Y. Acetate-assisted in situ electrodeposited β-MnO 2 for the fabrication of nano-architectonics for non-enzymatic glucose detection. RSC Adv 2024; 14:22359-22367. [PMID: 39010910 PMCID: PMC11247433 DOI: 10.1039/d4ra03930k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Accepted: 06/29/2024] [Indexed: 07/17/2024] Open
Abstract
Highly sensitive and low-cost electrocatalytic materials are of great importance for the commercial application of non-enzymatic glucose sensors. Herein, we fabricated a novel one-pot enzyme- and indicator-free method for the colorimetric sensing of blood glucose levels based on the direct redox reaction of β-MnO2/glucose. Owing to the introduction of ammonium acetate and the enhanced oxygen evolution reaction, the higher conductive β-MnO2 nanosheets with the larger surface area were directly grown in situ on the conductive substrate by a linear sweep voltammetry (LSV) electrodeposition method. Besides, owing to the unique tunnel-type pyrolusite MnO2, the electrolyte diffusion was facilitated and reduced the response time in the glucose detection process. Hence, the acetate-assisted MnO2 electrode exhibited a high sensitivity of 461.87 μA M-1 cm-2 toward glucose, a wide detection range from 1.0 μM to 1 mM, and a low detection limit of 0.47 μM while the electrode also maintained excellent selectivity and stability. These results clearly indicate that the new strategy we developed has great potential for practical applications.
Collapse
Affiliation(s)
- Tianbao Ren
- School of Business, Heze University Heze 274015
| | - Lijun Yan
- Department of Interior and Environmental Design, Pusan National University Pusan 46241 South Korea
| | - Yang Zhao
- Department of Urban and Regional Development, Hanyang University Seoul 04763 South Korea
| |
Collapse
|
4
|
Ghosh R, Li X, Yates MZ. Nonenzymatic Glucose Sensor Using Bimetallic Catalysts. ACS APPLIED MATERIALS & INTERFACES 2024; 16:17-29. [PMID: 38118131 PMCID: PMC10788829 DOI: 10.1021/acsami.3c10167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 11/25/2023] [Accepted: 11/28/2023] [Indexed: 12/22/2023]
Abstract
Bimetallic glucose oxidation electrocatalysts were synthesized by two electrochemical reduction reactions carried out in series onto a titanium electrode. Nickel was deposited in the first synthesis stage followed by either silver or copper in the second stage to form Ag@Ni and Cu@Ni bimetallic structures. The chemical composition, crystal structure, and morphology of the resulting metal coating of the titanium electrode were investigated by X-ray diffraction, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and electron microscopy. The electrocatalytic performance of the coated titanium electrodes toward glucose oxidation was probed using cyclic voltammetry and amperometry. It was found that the unique high surface area bimetallic structures have superior electrocatalytic activity compared to nickel alone. The resulting catalyst-coated titanium electrode served as a nonenzymatic glucose sensor with high sensitivity and low limit of detection for glucose. The Cu@Ni catalyst enables accurate measurement of glucose over the concentration range of 0.2-12 mM, which includes the full normal human blood glucose range, with the maximum level extending high enough to encompass warning levels for prediabetic and diabetic conditions. The sensors were also found to perform well in the presence of several chemical compounds found in human blood known to interfere with nonenzymatic sensors.
Collapse
Affiliation(s)
- Rashmi Ghosh
- Department of Chemical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Xiao Li
- Department of Chemical Engineering, University of Rochester, Rochester, New York 14627, United States
| | - Matthew Z. Yates
- Department of Chemical Engineering, University of Rochester, Rochester, New York 14627, United States
| |
Collapse
|
5
|
Govindaraj M, Srivastava A, Muthukumaran MK, Tsai PC, Lin YC, Raja BK, Rajendran J, Ponnusamy VK, Arockia Selvi J. Current advancements and prospects of enzymatic and non-enzymatic electrochemical glucose sensors. Int J Biol Macromol 2023; 253:126680. [PMID: 37673151 DOI: 10.1016/j.ijbiomac.2023.126680] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/19/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
This review discusses the most current developments and future perspectives in enzymatic and non-enzymatic glucose sensors, which have notably evolved over the preceding quadrennial period. Furthermore, a thorough exploration encompassed the sensor's intricate fabrication processes, the diverse range of materials employed, the underlying principles of detection, and an in-depth assessment of the sensors' efficacy in detecting glucose levels within essential bodily fluids such as human blood serums, urine, saliva, and interstitial fluids. It is worth noting that the accurate quantification of glucose concentrations within human blood has been effectively achieved by utilizing classical enzymatic sensors harmoniously integrated with optical and electrochemical transduction mechanisms. Monitoring glucose levels in various mediums has attracted exceptional attention from industrial to academic researchers for diabetes management, food quality control, clinical medicine, and bioprocess inspection. There has been an enormous demand for the creation of novel glucose sensors over the past ten years. Research has primarily concentrated on succeeding biocompatible and enhanced sensing abilities related to the present technologies, offering innovative avenues for more effective glucose sensors. Recent developments in wearable optical and electrochemical sensors with low cost, high stability, point-of-care testing, and online tracking of glucose concentration levels in biological fluids can aid in managing and controlling diabetes globally. New nanomaterials and biomolecules that can be used in electrochemical sensor systems to identify glucose concentration levels are developed thanks to advances in nanoscience and nanotechnology. Both enzymatic and non-enzymatic glucose electrochemical sensors have garnered much interest recently and have made significant strides in detecting glucose levels. In this review, we summarise several categories of non-enzymatic glucose sensor materials, including composites, non-precious transition metals and their metal oxides, hydroxides, precious metals and their alloys, carbon-based materials, conducting polymers, metal-organic framework (MOF)-based electrocatalysts, and wearable device-based glucose sensors deeply.
Collapse
Affiliation(s)
- Muthukumar Govindaraj
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India; Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan
| | - Ananya Srivastava
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi 221005, India
| | - Magesh Kumar Muthukumaran
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Pei-Chien Tsai
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, 602105, India
| | - Yuan-Chung Lin
- Institute of Environmental Engineering, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan.
| | - Bharathi Kannan Raja
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Jerome Rajendran
- Department of Electrical Engineering and Computer Science, The University of California, Irvine, CA 92697, United States
| | - Vinoth Kumar Ponnusamy
- Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Center for Emerging Contaminants Research, National Sun Yat-sen University, Kaohsiung 804, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City 807, Taiwan; Department of Medical Research, Kaohsiung Medical University Hospital (KMUH), Kaohsiung Medical University, Kaohsiung City 807, Taiwan; Department of Chemistry, National Sun Yat-sen University (NSYSU), Kaohsiung City 804, Taiwan.
| | - J Arockia Selvi
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India.
| |
Collapse
|
6
|
Kim SE, Yoon JC, Tae HJ, Muthurasu A. Electrospun Manganese-Based Metal-Organic Frameworks for MnO x Nanostructures Embedded in Carbon Nanofibers as a High-Performance Nonenzymatic Glucose Sensor. ACS OMEGA 2023; 8:42689-42698. [PMID: 38024713 PMCID: PMC10652823 DOI: 10.1021/acsomega.3c05459] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/15/2023] [Accepted: 10/17/2023] [Indexed: 12/01/2023]
Abstract
Material-specific electrocatalytic activity and electrode design are essential factors in evaluating the performance of electrochemical sensors. Herein, the technique described involves electrospinning manganese-based metal-organic frameworks (Mn-MOFs) to develop MnOx nanostructures embedded in carbon nanofibers. The resulting structure features an electrocatalytic material for an enzyme-free glucose sensor. The elemental composition, morphology, and microstructure of the fabricated electrodes materials were characterized by using energy-dispersive X-ray spectroscopy (EDX), field-emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM). Cyclic voltammetry (CV) and amperometric i-t (current-time) techniques are characteristically employed to assess the electrochemical performance of materials. The MOF MnOx-CNFs nanostructures significantly improve detection performance for nonenzymatic amperometric glucose sensors, including a broad linear range (0 mM to 9.1 mM), high sensitivity (4080.6 μA mM-1 cm-2), a low detection limit (0.3 μM, S/N = 3), acceptable selectivity, outstanding reproducibility, and stability. The strategy of metal and metal oxide-integrated CNF nanostructures based on MOFs opens interesting possibilities for the development of high-performance electrochemical sensors.
Collapse
Affiliation(s)
- So Eun Kim
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Jae Chol Yoon
- Department
of Emergency Medicine, Research Institute
of Clinical Medicine of Jeonbuk National University and Biomedical
Research Institute of Jeonbuk National University Hospital, Jeonju 54907, Republic of Korea
| | - Hyun-Jin Tae
- College
of Veterinary Medicine and Biosafety Research Institute, Jeonbuk National University, Iksan 54596, Republic of Korea
| | - Alagan Muthurasu
- Department
of Nano Convergence Technology, Jeonbuk
National University, Jeonju 54907, Republic
of Korea
| |
Collapse
|
7
|
Math C, Income K, Khachornsakkul K, Duenchay P, Dungchai W. A sensitive and facile electrochemical paper-based sensor for glucose detection in whole blood using the Pd/CB-Ni@rGO modified electrode. Analyst 2023; 148:4753-4761. [PMID: 37655604 DOI: 10.1039/d3an00879g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
We created novel Pd/CB-Ni@rGO nanomaterials for glucose detection. The as-synthesized nanomaterials were dropped on the electrode surface using the drop casting technique. The prepared electrode was then attached to a paper-based device containing the sample zone and the reaction zone, enabling plasma isolation and an enzymatic reaction for glucose detection in whole blood. The nanomaterials and surfaces of electrodes were characterized by FTIR, TEM, and SEM. The proposed approach is a disposable glucose detection method that is unaffected by protein fouling on the electrode, and it requires only one drop of human blood. Therefore, there is no need for extensive sample preparation, and there is less sample consumption. Under optimal conditions, Pd/CB-Ni@rGO can accurately measure blood glucose levels with a linear range of 7 to 7140 μM (R2 = 0.9986) and a low detection limit of 0.82 μM. Besides, the developed sensor shows excellent anti-interference capacity, stability, and satisfactory reproducibility and repeatability. Importantly, Pd/CB-Ni@rGO was successfully applied for glucose in whole blood from 4 volunteers, with results that correlated well with those obtained using an Accucheck glucometer at a 95% confidence level. Given its low cost, high accuracy, and ease of use, the blood glucose sensor holds significant potential for clinical use and broadens the area of future noninvasive sensor development.
Collapse
Affiliation(s)
- Chim Math
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand.
| | - Kamolwich Income
- Office of Primary Industries and Mines, Region 3, Ministry of Industry, Chiang Mai, Thailand
| | - Kawin Khachornsakkul
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand.
- Department of Electrical and Computer Engineering, Tufts University, Medford, MA 02155, USA
| | - Paweenar Duenchay
- Department of Industrial Engineering, Manufacturing Engineering, and Chemical Processes and Environment Engineering, Faculty of Engineering, Pathumwan Institute of Technology, 833 Rama 1Rd., Pathumwan, Bangkok 10330, Thailand
| | - Wijitar Dungchai
- Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand.
| |
Collapse
|
8
|
Bhaduri SN, Ghosh D, Debnath S, Biswas R, Chatterjee PB, Biswas P. Copper(II)-Incorporated Porphyrin-Based Porous Organic Polymer for a Nonenzymatic Electrochemical Glucose Sensor. Inorg Chem 2023; 62:4136-4146. [PMID: 36862998 DOI: 10.1021/acs.inorgchem.2c04072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
To date, the fabrication of multifunctional nanoplatforms based on a porous organic polymer for electrochemical sensing of biorelevant molecules has received considerable attention in the search for a more active, robust, and sensitive electrocatalyst. Here, in this report, we have developed a new porous organic polymer based on porphyrin (TEG-POR) from a polycondensation reaction between a triethylene glycol-linked dialdehyde and pyrrole. The Cu(II) complex of the polymer Cu-TEG-POR shows high sensitivity and a low detection limit for glucose electro-oxidation in an alkaline medium. The characterization of the as-synthesized polymer was done by thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy, and 13C CP-MAS solid-state NMR. The N2 adsorption/desorption isotherm was carried out at 77 K to analyze the porous property. TEG-POR and Cu-TEG-POR both show excellent thermal stability. The Cu-TEG-POR-modified GC electrode shows a low detection limit (LOD) value of 0.9 μM and a wide linear range (0.001-1.3 mM) with a sensitivity of 415.8 μA mM-1 cm-2 toward electrochemical glucose sensing. The interference of the modified electrode from ascorbic acid, dopamine, NaCl, uric acid, fructose, sucrose, and cysteine was insignificant. Cu-TEG-POR exhibits acceptable recovery for blood glucose detection (97.25-104%), suggesting its scope in the future for selective and sensitive nonenzymatic glucose detection in human blood.
Collapse
Affiliation(s)
- Samanka Narayan Bhaduri
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| | - Debojit Ghosh
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| | - Snehasish Debnath
- Analytical & Environmental Science Division and Centralized Instrument Facility, CSIR-CSMCRI, G. B. Marg, Bhavnagar 364002, Gujarat, India
| | - Rima Biswas
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| | - Pabitra B Chatterjee
- Analytical & Environmental Science Division and Centralized Instrument Facility, CSIR-CSMCRI, G. B. Marg, Bhavnagar 364002, Gujarat, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Papu Biswas
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| |
Collapse
|
9
|
Xu L, Zhang X, Wang Z, Haidry AA, Yao Z, Haque E, Wang Y, Li G, Daeneke T, McConville CF, Kalantar-Zadeh K, Zavabeti A. Low dimensional materials for glucose sensing. NANOSCALE 2021; 13:11017-11040. [PMID: 34152349 DOI: 10.1039/d1nr02529e] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Biosensors are essential components for effective healthcare management. Since biological processes occur on molecular scales, nanomaterials and nanosensors intrinsically provide the most appropriate landscapes for developing biosensors. Low-dimensional materials have the advantage of offering high surface areas, increased reactivity and unique physicochemical properties for efficient and selective biosensing. So far, nanomaterials and nanodevices have offered significant prospects for glucose sensing. Targeted glucose biosensing using such low-dimensional materials enables much more effective monitoring of blood glucose levels, thus providing significantly better predictive diabetes diagnostics and management. In this review, recent advances in using low dimensional materials for sensing glucose are summarized. Sensing fundamentals are discussed, as well as invasive, minimally-invasive and non-invasive sensing methods. The effects of morphological characteristics and size-dependent properties of low dimensional materials are explored for glucose sensing, and the key performance parameters such as selectivity, stability and sensitivity are also discussed. Finally, the challenges and future opportunities that low dimensional materials can offer for glucose sensing are outlined.
Collapse
Affiliation(s)
- Linling Xu
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100, China
| | - Xianfei Zhang
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100, China
| | - Zhe Wang
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100, China
| | - Azhar Ali Haidry
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100, China
| | - Zhengjun Yao
- College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 211100, China
| | - Enamul Haque
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Yichao Wang
- Institute for Frontier Materials, Deakin University, Waurn Ponds, Geelong, VIC 3216, Australia
| | - Gang Li
- Department of Chemical Engineering, The University of Melbourne, Parkville, VIC, 3010 Australia.
| | - Torben Daeneke
- School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Chris F McConville
- Institute for Frontier Materials, Deakin University, Waurn Ponds, Geelong, VIC 3216, Australia
| | - Kourosh Kalantar-Zadeh
- School of Chemical Engineering, University of New South Wales (UNSW), Kensington, NSW 2052, Australia.
| | - Ali Zavabeti
- Department of Chemical Engineering, The University of Melbourne, Parkville, VIC, 3010 Australia.
| |
Collapse
|
10
|
Incoherent microwaves heating of water: A combined experimental and simulated investigation. Chem Phys Lett 2021. [DOI: 10.1016/j.cplett.2021.138528] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
11
|
Mixture of carbon aerogel with Pd-WO3 nanorods for amperometric determination of mesalazine. Mikrochim Acta 2021; 188:135. [PMID: 33759064 DOI: 10.1007/s00604-021-04789-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Accepted: 03/15/2021] [Indexed: 10/21/2022]
Abstract
We prepared, for the first time, carbon aerogels support on Pd-WO3 nanorods (CAs/Pd-WO3) hybrid nanocomposite via sol-gel and microwave-assisted methods. The as-prepared CAs/Pd-WO3-modified electrode was used as effective electrocatalyst for nanomolar level detection of mesalazine (MSA). The typical porous nature of carbon aerogels effectively prevented the aggregation of Pd-doped WO3 nanorods and increased the electrochemically active surface area. In addition, the Pd-WO3 nanointerface provides intrinsic improvement of the electrocatalytic activity and stability for the electrochemical oxidation process, and the interconnected conducting network of the porous surfaces of CAs accelerated rapid electron transport at the working electrode. The synergistic effect of the CAs/Pd-WO3 architecture has excellent electrocatalytic activity for the detection of MSA with high sensitivity of 2.403 ± 0.004 μA μM-1 cm-2, low detection limit of 0.8 ± 0.3 nM and wide linear response from 0.003-350 μM at a low applied potential of 0.30 V vs. Ag|AgCl. Satisfactory results were observed for its analytical performance in detecting MSA in human blood serum and urine samples, and recoveries ranged from 98.8 to 100.4%. We believe that the architecture of the modified CAs/Pd-WO3 electrocatalysts can be effectively used in clinical applications for the detection of MSA.
Collapse
|
12
|
Synthesis of Au core flower surrounding with sulphur-doped thin Co3O4 shell for enhanced nonenzymatic detection of glucose. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
13
|
Wang Z, Zhang J, Jian R, Liao J, Xiong X, Huang K. Room temperature ultrafast synthesis of zinc oxide nanomaterials via hydride generation for non-enzymatic glucose detection. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105396] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
14
|
Absalan Y, Gholizadeh M, Butusov L, Bratchikova I, Kopylov V, Kovalchukova O. Titania nanotubes (TNTs) prepared through the complex compound of gallic acid with titanium; examining photocatalytic degradation of the obtained TNTs. ARAB J CHEM 2020. [DOI: 10.1016/j.arabjc.2020.02.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
15
|
Facile preparation of Ni nanoparticle embedded on mesoporous carbon nanorods for non-enzymatic glucose detection. J Colloid Interface Sci 2020; 583:310-320. [PMID: 33007587 DOI: 10.1016/j.jcis.2020.09.051] [Citation(s) in RCA: 55] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 09/11/2020] [Accepted: 09/14/2020] [Indexed: 02/07/2023]
Abstract
Transition metal doped carbon materials are recognized as promising sensing platforms for glucose detection. Herein, a simple strategy involving crystallinity, nanostructure engineering, and pyrolysis was developed for constructing well-defined Ni nanoparticle embedded on nanoporous carbon nanorods (Ni/NCNs). A three-dimensional nickel-based metal-organic framework (Ni-MOF) was used as both a self-sacrificing template and precursor. Due to the synergistic effects between the uniformly dispersed Ni nanoparticles and the nanoporous carbon matrix, the as-prepared Ni/NCNs exhibited remarkable electrochemical activity. The fabricated Ni/NCNs glucose sensor showed excellent electrocatalytic performance with ultra-low limit of detection, wide linear detection ranges, fast response times (within 1.6 s), superior stability, and anti-interference characteristics. Moreover, the Ni/NCNs sensing platform was successfully applied to analyze glucose concentrations in human blood samples. These results showed that Ni/NCNs hold potential applications in developing enzyme-free glucose sensors.
Collapse
|
16
|
Jiang H, Xia Q, Liu D, Ling K. Calcium-cation-doped polydopamine-modified 2D black phosphorus nanosheets as a robust platform for sensitive and specific biomolecule sensing. Anal Chim Acta 2020; 1121:1-10. [PMID: 32493583 DOI: 10.1016/j.aca.2020.04.072] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Revised: 02/29/2020] [Accepted: 04/28/2020] [Indexed: 02/05/2023]
Abstract
Many polymer decorated/modified 2D nanomaterials have been developed as enhanced drug delivery systems and photothermal theranostic nanoagents. However, few reports describe the use of these novel nanomaterials as nanoplatforms for biomolecule sensing. Herein, we used calcium-cation-doped polydopamine-modified (PDA-modified) 2D black phosphorus (BP) nanosheets (BP@PDA) as a sensing nanoplatform for the detection of nucleic acids and proteins in complex biological samples. Fluorescent-dye-labeled single-strand DNA aptamer/probes are adsorbed by the Ca2+-doped BP@PDA mediated by calcium-cation coordination. The PDA coating enhances the stability of the inner BP, provides binding sites to DNA nucleobases, and quenches fluorescence. Without any chemical conjugation, this sensing nanoplatform selectively and specifically detects protein (human thrombin, linear range: 10-25 nM, detection limit: 0.02 nM), single-strand DNA (linear range: 1-10 nM, detection limit: 0.52 nM) in 1% serum diluted samples, and senses intracellular mRNAs (C-myc, and actin) in living cells. The nanoplatform exhibits the advantages of both the 2D nanomaterial (BP) and the coating polymer (PDA), naturally enters living cells unaided by transfection agents, resists enzymatic lysis and shows high biocompatibility. This nanoplatform design contributes towards future biomolecule analytical method development based on polymer decorated/modified 2D nanomaterials.
Collapse
Affiliation(s)
- Hongyan Jiang
- Department of Pharmacy, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, China
| | - Qing Xia
- Department of Pharmacy, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, China
| | - Daojun Liu
- Department of Pharmacy, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, China
| | - Kai Ling
- Department of Pharmacy, Shantou University Medical College, No. 22 Xinling Road, Shantou, 515041, China.
| |
Collapse
|
17
|
Wei C, Kang C, Liu Q. Ag nanosheets grown on Cu nanowire-based flexible films for sensitive non-enzymatic glucose sensors. NANOTECHNOLOGY 2020; 31:115501. [PMID: 31751969 DOI: 10.1088/1361-6528/ab59ea] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Cu nanowire (Cu NW) and Ag nanosheet (Ag NS) bimetallic nanocomposites were fabricated on a flexible polyethylene terephthalate (PET) slice for non-enzymatic glucose sensing via a facile two-step approach, vacuum filtration, and galvanic displacement. Low-cost Cu NW-based conductive films were employed as the conductive substrates to substitute the traditional glassy carbon electrodes or indium tin oxide electrodes. The highly stable Ag NSs grow directly on the surface of Cu NWs without additional binders. The AgNO3 concentration and displacement time were adjusted to control the consumption of Cu NWs and the growth of Ag nanostructures. With the large load of Ag and the great connection of Cu NWs, a high sensitivity of 2033 μA mM-1cm-2, a fast amperometric response of 2 s, a wide linear range of 0.0015-4.02 mM, and a satisfactory result in human serum analysis were obtained by this novel Ag NS/Cu NW/PET sensor. Especially the sensitivity of the sensor was over four-fold higher than that of pure Cu NWs/PET, benefiting from the synergistic effect of bimetals. Furthermore, the Ag NS/Cu NW/PET sensor demonstrated a stable amperometric signal against mechanical bending. The material holds promise to use to fabricate flexible electrochemical devices.
Collapse
Affiliation(s)
- Chenhuinan Wei
- School of Physics and Technology, Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, Wuhan University, Wuhan 430072, People's Republic of China
| | | | | |
Collapse
|
18
|
A highly sensitive non-enzymatic glucose sensor based on CuS nanosheets modified Cu2O/CuO nanowire arrays. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135630] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
19
|
WITHDRAWN: Titania nanotubes (TNTs) prepared through the complex compound of gallic acid with titanium; examining photocatalytic degradation of the obtained TNTs. ARAB J CHEM 2020. [DOI: 10.1016/j.arabjc.2020.02.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
20
|
Olejnik A, Siuzdak K, Karczewski J, Grochowska K. A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures. ELECTROANAL 2019. [DOI: 10.1002/elan.201900455] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Adrian Olejnik
- Faculty of ChemistryGdańsk University of Technology Narutowicza 11/12 St. 80-233 Gdańsk Poland
| | - Katarzyna Siuzdak
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow MachineryPolish Academy of Sciences Fiszera 14 St. 80-231 Gdańsk Poland
| | - Jakub Karczewski
- Faculty of Applied Physics and MathematicsGdańsk University of Technology Narutowicza 11/12 St. 80-233 Gdańsk Poland
| | - Katarzyna Grochowska
- Centre for Plasma and Laser Engineering, The Szewalski Institute of Fluid-Flow MachineryPolish Academy of Sciences Fiszera 14 St. 80-231 Gdańsk Poland
| |
Collapse
|
21
|
Non-enzymatic flexible glucose sensing platform based on nanostructured TiO2 – Au composite. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.02.040] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
22
|
Cong W, Miao R, Tao B, Miao F. MnO2/ZnCo2O4 with binder-free arrays on nickel foam loaded with graphene as a high performance electrode for advanced asymmetric supercapacitors. RSC Adv 2019; 9:32889-32897. [PMID: 35529737 PMCID: PMC9073179 DOI: 10.1039/c9ra04598h] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 09/26/2019] [Indexed: 11/24/2022] Open
Abstract
ZnCo2O4 nanosheets were successfully arrayed on a Ni foam surface with graphene using a hydrothermal method followed by annealing treatment; then MnO2 nanoparticles were electrodeposited on the ZnCo2O4 nanosheets to obtain a synthesized composite binder-free electrode named MnO2/ZnCo2O4/graphene/Ni foam (denoted as MnO2/ZnCo2O4/G/NF). After testing the binder-free composite electrode of MnO2/ZnCo2O4/G/NF via cyclic voltammetry, galvanostatic charge–discharge and electrochemical impedance spectroscopy testing, we found that it exhibited ultrahigh electrochemical properties, with a high specific areal capacitance of 3405.21 F g−1 under a current density of 2 A g−1, and wonderful cycling stability, with 91.2% retention after 5000 cycles. Moreover, an asymmetric supercapacitor (ASC) based on MnO2/ZnCo2O4/G/NF//G/NF was successfully designed. When tested, the as-designed ASC can achieve a maximum energy density of 46.85 W h kg−1 at a power density of 166.67 W kg−1. Finally, the ASC we assembled can power a commercial red LED lamp successfully for more than 5 min, which proves its practicability. All these impressive performances indicate that the MnO2/ZnCo2O4/graphene composite material is an outstanding electrode material for electrochemical capacitors. Schematic illustration of formation process of MnO2/ZnCo2O4/G/NF composite electrode.![]()
Collapse
Affiliation(s)
- Wanjuan Cong
- College of Communications and Electronics Engineering
- Qiqihar University
- China
- College of Computer and Information Engineering
- Heihe University
| | - Rui Miao
- College of Communications and Electronics Engineering
- Qiqihar University
- China
| | - Bairui Tao
- College of Communications and Electronics Engineering
- Qiqihar University
- China
| | - Fengjuan Miao
- College of Communications and Electronics Engineering
- Qiqihar University
- China
| |
Collapse
|
23
|
Li Q, Zheng S, Hu X, Shao Z, Zheng M, Pang H. Ultrathin Nanosheet Ni‐Metal Organic Framework Assemblies for High‐Efficiency Ascorbic Acid Electrocatalysis. ChemElectroChem 2018. [DOI: 10.1002/celc.201801247] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Affiliation(s)
- Qing Li
- Guangling CollegeSchool of Chemistry and Chemical EngineeringYangzhou University Yangzhou 225009, Jiangsu P. R. China
| | - Shasha Zheng
- Guangling CollegeSchool of Chemistry and Chemical EngineeringYangzhou University Yangzhou 225009, Jiangsu P. R. China
| | - Xiao Hu
- Xiao Hu, Kuang Yaming Honors SchoolNanjing University Nanjing 210023, Jiangsu P. R. China
| | - Zhifang Shao
- Guangling CollegeSchool of Chemistry and Chemical EngineeringYangzhou University Yangzhou 225009, Jiangsu P. R. China
| | - Mingbo Zheng
- Guangling CollegeSchool of Chemistry and Chemical EngineeringYangzhou University Yangzhou 225009, Jiangsu P. R. China
| | - Huan Pang
- Guangling CollegeSchool of Chemistry and Chemical EngineeringYangzhou University Yangzhou 225009, Jiangsu P. R. China
| |
Collapse
|