1
|
Rink S, Baeumner AJ. Progression of Paper-Based Point-of-Care Testing toward Being an Indispensable Diagnostic Tool in Future Healthcare. Anal Chem 2023; 95:1785-1793. [PMID: 36608282 DOI: 10.1021/acs.analchem.2c04442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Point-of-care (POC) diagnostics in particular focuses on the timely identification of harmful conditions close to the patients' needs. For future healthcare these diagnostics could be an invaluable tool especially in a digitalized or telemedicine-based system. However, while paper-based POC tests, with the most prominent example being the lateral flow assay (LFA), have been especially successful due to their simplicity and timely response, the COVID-19 pandemic highlighted their limitations, such as low sensitivity and ambiguous responses. This perspective discusses strategies that are currently being pursued to evolve such paper-based POC tests toward a superior diagnostic tool that provides high sensitivities, objective result interpretation, and multiplexing options. Here, we pinpoint the challenges with respect to (i) measurability and (ii) public applicability, exemplified with select cases. Furthermore, we highlight promising endeavors focused on (iii) increasing the sensitivity, (iv) multiplexing capability, and (v) objective evaluation to also ready the technology for integration with machine learning into digital diagnostics and telemedicine. The status quo in academic research and industry is outlined, and the likely highly relevant role of paper-based POC tests in future healthcare is suggested.
Collapse
Affiliation(s)
- Simone Rink
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Antje J Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
2
|
Capkin E, Kurt H, Gurel B, Bicak D, Akgun Bas S, Daglikoca DE, Yuce M. Characterization of FcγRIa (CD64) as a Ligand Molecule for Site-Specific IgG1 Capture: A Side-By-Side Comparison with Protein A. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:14623-14634. [PMID: 36416530 PMCID: PMC9730901 DOI: 10.1021/acs.langmuir.2c02022] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 11/12/2022] [Indexed: 06/16/2023]
Abstract
Fc γ receptors (FcγRs) are one of the structures that can initiate effector function for monoclonal antibodies. FcγRIa has the highest affinity toward IgG1-type monoclonal antibodies among all FcγRs. In this study, a comprehensive characterization was performed for FcγRIa as a potential affinity ligand for IgG1-type monoclonal antibody binding. The binding interactions were assessed with the SPR technique using different immobilization techniques such as EDC-NHS coupling, streptavidin-biotin interaction, and His-tagged FcγRIa capture. The His-tagged FcγRIa capture was the most convenient method based on assay repeatability. Next, a crude IgG1 sample and its fractions with different monomer contents obtained from protein A affinity chromatography were used to evaluate FcγRIa protein in terms of monoclonal antibody binding capacity. The samples were also compared with a protein A-immobilized chip (a frequently used affinity ligand) for IgG1 binding responses. The antibody binding capacity of the protein A-immobilized chip surface was significantly better than that of the FcγRIa-immobilized chip surface due to its 5 Ig binding domains. The antibody binding responses changed similarly with protein A depending on the monomer content of the sample. Finally, a different configuration was used to assess the binding affinity of free FcγRs (FcγRIa, FcγRIIa, and FcγRIIIa) to three different immobilized IgGs by immobilizing protein L to the chip surface. Unlike previous immobilization techniques tested where the FcγRIa was utilized as a ligand, nonimmobilized or free FcγRIa resulted in a significantly higher antibody binding response than free protein A. In this configuration, kinetics data of FcγRI revealed that the association rate (ka 50-80 × 105 M-1 s-1) increased in comparison to His capture method (1.9-2.4 × 105 M-1 s-1). In addition, the dissociation rate (kd 10-5 s-1) seemed slower over the His capture method (10-4 s-1) and provided stability on the chip surface during the dissociation phase. The KD values for FcγRIa were found in the picomolar range (2.1-10.33 pM from steady-state affinity analysis and 37.5-46.2 pM from kinetic analysis) for IgG1-type antibodies. FcγRIa possesses comparable ligand potential as well as protein A. Even though the protein A-immobilized surface bound more antibodies than the FcγRIa-captured surface, FcγRIa presented a significant antibody binding capacity in protein L configuration. The results suggest FcγRIa protein as a potential ligand for site-oriented immobilization of IgG1-type monoclonal antibodies, and it needs further performance investigation on different surfaces and interfaces for applications such as sensing and antibody purification.
Collapse
Affiliation(s)
- Eda Capkin
- Faculty
of Engineering and Natural Sciences, Sabanci
University, Tuzla 34956, Istanbul, Turkey
| | - Hasan Kurt
- School
of Engineering and Natural Sciences, Istanbul
Medipol University, Beykoz 34810, Istanbul, Turkey
- SABITA
Research Institute for Health Sciences and Technologies, Istanbul Medipol University, Beykoz 34810, Istanbul, Turkey
- Nanosolar
Plasmonics Ltd., Gebze 41400, Kocaeli, Turkey
| | - Busra Gurel
- SUNUM
Nanotechnology Research and Application Center, Sabanci University, Tuzla 34956, Istanbul, Turkey
| | - Dilan Bicak
- ILKO ARGEM
Biotechnology R&D Center, Pendik 34906, Istanbul, Turkey
| | - Sibel Akgun Bas
- ILKO ARGEM
Biotechnology R&D Center, Pendik 34906, Istanbul, Turkey
| | | | - Meral Yuce
- SUNUM
Nanotechnology Research and Application Center, Sabanci University, Tuzla 34956, Istanbul, Turkey
| |
Collapse
|
3
|
Sena-Torralba A, Álvarez-Diduk R, Parolo C, Piper A, Merkoçi A. Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials. Chem Rev 2022; 122:14881-14910. [PMID: 36067039 PMCID: PMC9523712 DOI: 10.1021/acs.chemrev.1c01012] [Citation(s) in RCA: 52] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
![]()
Lateral flow assays (LFAs) are currently the most used
point-of-care
sensors for both diagnostic (e.g., pregnancy test, COVID-19 monitoring)
and environmental (e.g., pesticides and bacterial monitoring) applications.
Although the core of LFA technology was developed several decades
ago, in recent years the integration of novel nanomaterials as signal
transducers or receptor immobilization platforms has brought improved
analytical capabilities. In this Review, we present how nanomaterial-based
LFAs can address the inherent challenges of point-of-care (PoC) diagnostics
such as sensitivity enhancement, lowering of detection limits, multiplexing,
and quantification of analytes in complex samples. Specifically, we
highlight the strategies that can synergistically solve the limitations
of current LFAs and that have proven commercial feasibility. Finally,
we discuss the barriers toward commercialization and the next generation
of LFAs.
Collapse
Affiliation(s)
- Amadeo Sena-Torralba
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain.,Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain
| | - Ruslan Álvarez-Diduk
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Claudio Parolo
- Barcelona Institute for Global Health (ISGlobal) Hospital Clínic-Universitat de Barcelona, Carrer del Rosselló 132, 08036 Barcelona, Spain
| | - Andrew Piper
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain.,Catalan Institution for Research and Advanced Studies (ICREA), Pg. Lluís Companys 23, 08010 Barcelona, Spain
| |
Collapse
|
4
|
Cheng X, Yang Y, Song Y, Xu LP, Wang S. Utilizing Heterostructured Porous Particles to Improve Traditional Paper Chromatography for Spontaneous Protein Separation. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:4250-4255. [PMID: 35353528 DOI: 10.1021/acs.langmuir.1c03394] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Chromatography is a classical technique for protein separation. However, the chromatography column is filled with tightly packed separation materials and requires an additional pressurizing pump to propel the flow of fluidic samples, largely restraining their applications. Here, we combine heterostructured porous particles with paper strips, realizing spontaneous separation of similarly sized proteins. The interconnected nanofibrous structure and good hydrophility of paper strips enable the spontaneous flow of the liquid sample, and the heterostructured porous particles provide versatile tools for protein separation via electrostatic interaction. The fabricated paper strips are inexpensive, user-friendly, and disposable and exhibit good separation performance. This work may offer a new avenue for fabricating on-site bioseparation tools and purifying various biomacromolecules.
Collapse
Affiliation(s)
- Xu Cheng
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, P. R. China
| | - Yuemeng Yang
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, P. R. China
| | - Yongyang Song
- CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, CAS Center for Excellence in Nanoscience, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, P. R. China
| | - Li-Ping Xu
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing 100083, P. R. China
| | - Shutao Wang
- CAS Key Laboratory of Bio-inspired Materials and Interfacial Science, CAS Center for Excellence in Nanoscience, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| |
Collapse
|
5
|
Chen X, Ding L, Huang X, Xiong Y. Tailoring noble metal nanoparticle designs to enable sensitive lateral flow immunoassay. Am J Cancer Res 2022; 12:574-602. [PMID: 34976202 PMCID: PMC8692915 DOI: 10.7150/thno.67184] [Citation(s) in RCA: 52] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 11/09/2021] [Indexed: 12/13/2022] Open
Abstract
Lateral flow immunoassay (LFIA) with gold nanoparticles (AuNPs) as signal reporters is a popular point-of-care diagnostic technique. However, given the weak absorbance of traditional 20-40 nm spherical AuNPs, their sensitivity is low, which greatly limits the wide application of AuNP-based LFIA. With the rapid advances in materials science and nanotechnology, the synthesis of noble metal nanoparticles (NMNPs) has enhanced physicochemical properties such as optical, plasmonic, catalytic, and multifunctional activity by simply engineering their physical parameters, including the size, shape, composition, and external structure. Using these engineered NMNPs as an alternative to traditional AuNPs, the sensitivity of LFIA has been significantly improved, thereby greatly expanding the working range and application scenarios of LFIA, particularly in trace analysis. Therefore, in this review, we will focus on the design of engineered NMNPs and their demonstration in improving LFIA. We highlight the strategies available for tailoring NMNP designs, the effect of NMNP engineering on their performance, and the working principle of each engineering design for enhancing LFIA. Finally, current challenges and future improvements in this field are briefly discussed.
Collapse
|