1
|
Tian T, Yang W, Wang X, Liu T, Pan B, Guo W, Wang B. Click chemistry-enabled gold nanorods for sensitive detection and viability evaluation of copper(II)-reducing bacteria. Mater Today Bio 2025; 30:101453. [PMID: 39866790 PMCID: PMC11764086 DOI: 10.1016/j.mtbio.2025.101453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Revised: 11/16/2024] [Accepted: 01/03/2025] [Indexed: 01/28/2025] Open
Abstract
The rise of antibiotic resistance poses a significant and ongoing challenge to public health, with pathogenic bacteria remaining a persistent threat. Traditional culture methods, while considered the gold standard for bacterial detection and viability assessment, are time-consuming and labor-intensive. To address this limitation, we developed a novel point-of-care (POC) detection method leveraging citrate- and alkyne-modified gold nanorods (AuNRs) synthesized with click chemistry properties. These AuNRs exhibit superior biocompatibility and enhanced quantitative performance compared to conventional surfactant-modified AuNRs. Our method, termed AuNRs-bacteria-initiated click chemistry (AuNRs-BICC), detects CuII-reducing bacteria by quantifying AuNRs bound to a biosensing interface via bacteria-mediated CuII reduction to CuI and subsequent click chemistry with biosensing interface of azide modifications. Using dark-field microscopy (DFM), we demonstrated a strong linear correlation between AuNR counts and the logarithm of bacterial concentration for both Gram-negative Escherichia coli (including KPC-2-expressing antibiotic-resistant strains) and Gram-positive Staphylococcus aureus across a range of 101 to 107 cells, achieving a remarkable detection limit of 101 cells. The AuNRs-BICC biosensor exhibits high selectivity for target bacterial strains and provides rapid detection within 3 h. Furthermore, it can assess bacterial viability in the presence of various antibiotics, including meropenem, ceftriaxone and tetracycline, suggesting its potential for rapid antibiotic susceptibility testing and facilitating timely clinical intervention for infectious diseases.
Collapse
Affiliation(s)
- Tongtong Tian
- Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China
| | - Wenjing Yang
- Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China
| | - Xiaohuan Wang
- Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China
| | - Te Liu
- Shanghai Geriatric Institute of Chinese Medicine, Shanghai University of Traditional Chinese Medicine, No. 725 South Wan Ping Road, Shanghai, 200031, PR China
| | - Baishen Pan
- Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China
| | - Wei Guo
- Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China
- Department of Laboratory Medicine, Shanghai Geriatric Medical Center, Shanghai, 201100, PR China
- Department of Laboratory Medicine, Wusong Central Hospital, Baoshan District, Shanghai, 200940, PR China
- Department of Laboratory Medicine, Xiamen Branch, Zhongshan Hospital, Fudan University, 361015, PR China
| | - Beili Wang
- Department of Laboratory Medicine, Zhongshan Hospital, Fudan University, 136 Yi Xue Yuan Road, Shanghai, 200032, PR China
| |
Collapse
|
2
|
Remmel M, Scheiderer L, Butkevich AN, Bossi ML, Hell SW. Accelerated MINFLUX Nanoscopy, through Spontaneously Fast-Blinking Fluorophores. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2206026. [PMID: 36642798 DOI: 10.1002/smll.202206026] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 11/24/2022] [Indexed: 06/17/2023]
Abstract
The introduction of MINFLUX nanoscopy allows single molecules to be localized with one nanometer precision in as little as one millisecond. However, current applications have so far focused on increasing this precision by optimizing photon collection, rather than minimizing the localization time. Concurrently, commonly used fluorescent switches are specifically designed for stochastic methods (e.g., STORM), optimized for a high photon yield and rather long on-times (tens of milliseconds). Here, accelerated MINFLUX nanoscopy with up to a 30-fold gain in localization speed is presented. The improvement is attained by designing spontaneously blinking fluorescent markers with remarkably fast on-times, down to 1-3 ms, matching the iterative localization process used in a MINFLUX microscope. This design utilizes a silicon rhodamine amide core, shifting the spirocyclization equilibrium toward an uncharged closed form at physiological conditions and imparting intact live cell permeability, modified with a fused (benzo)thiophene spirolactam fragment. The best candidate for MINFLUX microscopy (also suitable for STORM imaging) is selected through detailed characterization of the blinking behavior of single fluorophores, bound to different protein tags. Finally, optimization of the localization routines, customized to the fast blinking times, renders a significant speed improvement on a commercial MINFLUX microscope.
Collapse
Affiliation(s)
- Michael Remmel
- Department of Optical Nanoscopy, Max Planck Institute for Medical Research, Jahnstrasse 29, 69120, Heidelberg, Germany
| | - Lukas Scheiderer
- Department of Optical Nanoscopy, Max Planck Institute for Medical Research, Jahnstrasse 29, 69120, Heidelberg, Germany
| | - Alexey N Butkevich
- Department of NanoBiophotonics, Max Planck Institute for Multidisciplinary Sciences, Am Fassberg 11, 37077, Göttingen, Germany
| | - Mariano L Bossi
- Department of NanoBiophotonics, Max Planck Institute for Multidisciplinary Sciences, Am Fassberg 11, 37077, Göttingen, Germany
| | - Stefan W Hell
- Department of Optical Nanoscopy, Max Planck Institute for Medical Research, Jahnstrasse 29, 69120, Heidelberg, Germany
- Department of NanoBiophotonics, Max Planck Institute for Multidisciplinary Sciences, Am Fassberg 11, 37077, Göttingen, Germany
| |
Collapse
|
3
|
Hass K, Bao M, He Q, Liu L, He J, Park M, Qin P, Du K. Integrated Micropillar Polydimethylsiloxane Accurate CRISPR Detection System for Viral DNA Sensing. ACS OMEGA 2020; 5:27433-27441. [PMID: 33134706 PMCID: PMC7594154 DOI: 10.1021/acsomega.0c03917] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 09/30/2020] [Indexed: 05/13/2023]
Abstract
A fully Integrated Micropillar Polydimethylsiloxane Accurate CRISPR deTection (IMPACT) system is developed for viral DNA detection. This powerful system is patterned with high-aspect-ratio micropillars to enhance reporter probe binding. After surface modification and probe immobilization, the CRISPR-Cas12a/crRNA complex is injected into the fully enclosed microchannel. With the presence of a double-stranded DNA target, the CRISPR enzyme is activated and denatures the single-stranded DNA reporters from the micropillars. This collateral cleavage releases fluorescence reporters into the assay, and the intensity is linearly proportional to the target DNA concentration ranging from 0.1 to 10 nM. Importantly, this system does not rely on the traditional dye-quencher-labeled probe, thus reducing the fluorescence background presented in the assay. Furthermore, our one-step detection protocol is performed on-chip at isothermal conditions (37 °C) without using complicated and time-consuming off-chip probe hybridization and denaturation. This miniaturized and fully packed IMPACT chip demonstrates sensitive and accurate DNA detection within 120 min and paves ways to the next-generation point-of-care diagnostics, responding to emerging and deadly pathogen outbreaks.
Collapse
Affiliation(s)
- Kenneth
N. Hass
- Department
of Mechanical Engineering, Rochester Institute
of Technology, Rochester, New York 14623, United States
| | - Mengdi Bao
- Department
of Mechanical Engineering, Rochester Institute
of Technology, Rochester, New York 14623, United States
| | - Qian He
- Center
of Precision Medicine and Healthcare, Tsinghua-Berkeley
Shenzhen Institute, Shenzhen, Guangdong Province 518055, China
| | - Li Liu
- Department
of Microsystems Engineering, Rochester Institute
of Technology, Rochester, New York 14623, United States
| | - Jiacheng He
- Department
of Mechanical Engineering, Rochester Institute
of Technology, Rochester, New York 14623, United States
| | - Myeongkee Park
- Department
of Chemistry, Dong-A University, Busan 49315, Republic of Korea
| | - Peiwu Qin
- Center
of Precision Medicine and Healthcare, Tsinghua-Berkeley
Shenzhen Institute, Shenzhen, Guangdong Province 518055, China
| | - Ke Du
- Department
of Mechanical Engineering, Rochester Institute
of Technology, Rochester, New York 14623, United States
- Department
of Microsystems Engineering, Rochester Institute
of Technology, Rochester, New York 14623, United States
- School
of Chemistry and Materials Science, Rochester
Institute of Technology, Rochester, New York 14623, United States
| |
Collapse
|
4
|
Wu Y, Lian J, Gonçales VR, Pardehkhorram R, Tang W, Tilley RD, Gooding JJ. Patterned Molecular Films of Alkanethiol and PLL-PEG on Gold-Silicate Interfaces: How to Add Functionalities while Retaining Effective Antifouling. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:5243-5250. [PMID: 32323996 DOI: 10.1021/acs.langmuir.0c00586] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Spatial control of surface functionalization and interactions is essential for microarray-based analysis. This study reports the fabrication of two-dimensional molecular films with site-specific functionalities, forming microarrays at discrete locations. Arrays of microsized gold disks were produced on a silicate membrane using microfabrication. On these arrays, orthogonal self-assembly of molecules was performed that can specifically bind to gold or silicate. The gold array elements were functionalized with a range of alkanethiols and the silicate with polymeric poly-l-lysine-grafted-poly(ethylene glycol) (PLL-PEG). The surface functionalization on the gold disk array and the surrounding substrate was characterized at each step using X-ray photoelectron spectroscopy (XPS) to show that alkanethiols are specifically attached to the gold. PLL-PEG was used to provide resistance against nonspecific protein and cell adsorption and attached exclusively to the silicate. The effectiveness of the surface chemistry was validated by the selective self-assembly of a gold nanoparticle monolayer array on the gold regions. In a more sophisticated example, selective adhesion of MCF-7 cells to anti-EpCAM antibody modified gold areas of the gold-silicate surface was demonstrated to give a cell microarray. This study provides a general approach to fabricate chemical patterns on silicon-based devices with the convergence of microfabrication and material-specific surface modification, which may be useful to expand the functionalities and potential applications for patterned biomolecular films. Importantly, the ability to pattern surfaces with different surface chemistries is not limited to planar surfaces using this orthogonal surface-coupling approach.
Collapse
Affiliation(s)
- Yanfang Wu
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
- Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Jiaxin Lian
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
- Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Vinicius R Gonçales
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
- Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Raheleh Pardehkhorram
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Wenxian Tang
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
- Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - Richard D Tilley
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
- Electron Microscope Unit, Mark Wainwright Analytical Centre, University of New South Wales, Sydney, New South Wales 2052, Australia
| | - J Justin Gooding
- School of Chemistry, Australian Centre for NanoMedicine, University of New South Wales, Sydney, New South Wales 2052, Australia
- Australian Research Council Centre of Excellence in Convergent Bio-Nano Science and Technology, University of New South Wales, Sydney, New South Wales 2052, Australia
| |
Collapse
|
5
|
Wang Y, Yang Y, Chen C, Wang S, Wang H, Jing W, Tao N. One-Step Digital Immunoassay for Rapid and Sensitive Detection of Cardiac Troponin I. ACS Sens 2020; 5:1126-1131. [PMID: 32180397 DOI: 10.1021/acssensors.0c00064] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A rapid and sensitive method to detect cardiac troponin I (cTnI) in human blood is critical to the diagnosis and treatment of acute myocardial infarction (AMI). Here, we describe a simple one-step digital immunoassay for single-molecule detection without washing steps. A sample containing cTnI mixed with detection antibody-conjugated gold nanoparticles (AuNPs) is added to a capture antibody-coated sensor surface and the formation of the antibody-cTnI-antibody sandwich is detected by digitally counting the binding of the individual gold nanoparticles to the sensor surface in real time using a bright-field optical imaging setup together with a differential imaging algorithm. The digital immunoassay detects cTnI in undiluted human plasma, which achieves a detection limit of 5.7 ng/L within a detection time of only 10 min, which meets the requirement of current clinical high-sensitivity troponin assay (∼70 ng/L cutoff). We anticipate that the one-step and real-time digital immunoassay can be applied to the detection of other disease biomarkers in blood.
Collapse
Affiliation(s)
- Yi Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Yunze Yang
- Biodesign Center for Bioelectronics and Biosensors, and School of Electrical, Energy and Computer Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Chao Chen
- Biodesign Center for Bioelectronics and Biosensors, and School of Electrical, Energy and Computer Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Shaopeng Wang
- Biodesign Center for Bioelectronics and Biosensors, and School of Electrical, Energy and Computer Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Hui Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
| | - Wenwen Jing
- Biodesign Center for Bioelectronics and Biosensors, and School of Electrical, Energy and Computer Engineering, Arizona State University, Tempe, Arizona 85287, United States
| | - Nongjian Tao
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China
- Biodesign Center for Bioelectronics and Biosensors, and School of Electrical, Energy and Computer Engineering, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
6
|
Sun Y, Park B, Ha JH, Kang SH. Voltage program-based MEKC with LIF detection for rapid quantification of native capsaicin and dihydrocapsaicin in foods. Food Chem 2020; 323:126831. [PMID: 32334311 DOI: 10.1016/j.foodchem.2020.126831] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 04/14/2020] [Accepted: 04/14/2020] [Indexed: 01/23/2023]
Abstract
Voltage program (VP)-based micellar electrokinetic chromatography (MEKC) with a laser-induced fluorescence (LIF) detector was developed for fast, high-sensitivity detection of native capsaicin (CAP) and dihydrocapsaicin (DHC) in various foods. The combination of mixed nonionic (Tween 20) and anionic (SDS) surfactants in a sodium borate running buffer showed excellent separation efficiency, selectivity, and speed without loss of resolving power (Rs > 2). Compared to conventional UV absorption, LIF showed enhanced detection sensitivity with detection limits at the pM level. In addition, the developed VP-based MEKC-LIF method was successfully applied for quantification of capsaicin in chili pepper, baechu, and kimchi at a 98% confidence level. CAP and DHC were also analyzed within a short time in extracts from real samples of gochujang, snacks (Swingchip®), black pepper, and ginger but were not detected in garlic.
Collapse
Affiliation(s)
- Yucheng Sun
- Department of Chemistry, Graduate School, Kyung Hee University, Yongin-si, Gyeonggi-do 17104, Republic of Korea
| | - Boyeon Park
- Hygienic Safety and Analysis Center, World Institute of Kimchi, Gwangju 61755, Republic of Korea
| | - Ji-Hyoung Ha
- Hygienic Safety and Analysis Center, World Institute of Kimchi, Gwangju 61755, Republic of Korea
| | - Seong Ho Kang
- Department of Chemistry, Graduate School, Kyung Hee University, Yongin-si, Gyeonggi-do 17104, Republic of Korea; Department of Applied Chemistry and Institute of Natural Sciences, Kyung Hee University, Yongin-si, Gyeonggi-do 17104, Republic of Korea.
| |
Collapse
|
7
|
Zhang H, Huang X, Liu J, Liu B. Simultaneous and ultrasensitive detection of multiple microRNAs by single-molecule fluorescence imaging. Chem Sci 2020; 11:3812-3819. [PMID: 34122849 PMCID: PMC8152581 DOI: 10.1039/d0sc00580k] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 03/23/2020] [Indexed: 11/24/2022] Open
Abstract
Cell status changes are typically accompanied by the simultaneous changes of multiple microRNA (miRNA) levels. Thus, simultaneous and ultrasensitive detection of multiple miRNA biomarkers shows great promise in early cancer diagnosis. Herein, a facile single-molecule fluorescence imaging assay was proposed for the simultaneous and ultrasensitive detection of multiple miRNAs using only one capture anti-DNA/RNA antibody (S9.6 antibody). Two complementary DNAs (cDNAs) designed to hybridize with miRNA-21 and miRNA-122 were labelled with Cy3 (cDNA1) and Cy5 (cDNA2) dyes at their 5'-ends, respectively. After hybridization, both miRNA-21/cDNA1 and miRNA-122/cDNA2 complexes were captured by S9.6 antibodies pre-modified on a coverslip surface. Subsequently, the Cy3 and Cy5 dyes on the coverslip surface were imaged by the single-molecule fluorescence setup. The amount of miRNA-21 and miRNA-122 was quantified by counting the image spots from the Cy3 and Cy5 dye molecules in the green and red channels, respectively. The proposed assay displayed high specificity and sensitivity for singlet miRNA detection both with a detection limit of 5 fM and for multiple miRNA detection both with a detection limit of 20 fM. Moreover, it was also demonstrated that the assay could be used to detect multiple miRNAs simultaneously in human hepatocellular cancer cells (HepG2 cells). The proposed assay provides a novel biosensing platform for the ultrasensitive and simple detection of multiple miRNA expressions and shows great prospects for early cancer diagnosis.
Collapse
Affiliation(s)
- Hongding Zhang
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institute of Biomedical Sciences, Fudan University Shanghai 200438 P. R. China
- College of Chemistry and Chemical Engineering, Xinyang Normal University Xinyang 464000 P. R. China
| | - Xuedong Huang
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institute of Biomedical Sciences, Fudan University Shanghai 200438 P. R. China
| | - Jianwei Liu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institute of Biomedical Sciences, Fudan University Shanghai 200438 P. R. China
| | - Baohong Liu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institute of Biomedical Sciences, Fudan University Shanghai 200438 P. R. China
| |
Collapse
|
8
|
Jing W, Wang Y, Yang Y, Wang Y, Ma G, Wang S, Tao N. Time-Resolved Digital Immunoassay for Rapid and Sensitive Quantitation of Procalcitonin with Plasmonic Imaging. ACS NANO 2019; 13:8609-8617. [PMID: 31276361 PMCID: PMC7008466 DOI: 10.1021/acsnano.9b02771] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Timely diagnosis of acute diseases improves treatment outcomes and saves lives, but it requires fast and precision quantification of biomarkers. Here, we report a time-resolved digital immunoassay based on plasmonic imaging of binding of single nanoparticles to biomarkers captured on a sensor surface. The real-time and high contrast of plasmonic imaging lead to fast and precise counting of the individual biomarkers over a wide dynamic range. We demonstrated the detection principle, evaluated the performance of the method using procalcitonin (PCT) as an example, and achieved a limit of detection of ∼2.8 pg/mL, dynamic range of 4.2-12500 pg/mL, for a total detection time of ∼25 min.
Collapse
Affiliation(s)
- Wenwen Jing
- Biodesign Center for Biosensors and Bioelectronics, Arizona State University, Tempe, Arizona 85287, USA
| | - Yan Wang
- Biodesign Center for Biosensors and Bioelectronics, Arizona State University, Tempe, Arizona 85287, USA
| | - Yunze Yang
- Biodesign Center for Biosensors and Bioelectronics, Arizona State University, Tempe, Arizona 85287, USA
| | - Yi Wang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | - Guangzhong Ma
- Biodesign Center for Biosensors and Bioelectronics, Arizona State University, Tempe, Arizona 85287, USA
| | - Shaopeng Wang
- Biodesign Center for Biosensors and Bioelectronics, Arizona State University, Tempe, Arizona 85287, USA
| | - Nongjian Tao
- Biodesign Center for Biosensors and Bioelectronics, Arizona State University, Tempe, Arizona 85287, USA
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona 85287, USA
| |
Collapse
|
9
|
Zhang H, Zhang K, Yao Y, Liu Y, Ji J, Huang X, Liu J, Liu B. Single-Molecule Fluorescence Imaging for Ultrasensitive DNA Methyltransferase Activity Measurement and Inhibitor Screening. Anal Chem 2019; 91:9500-9507. [PMID: 31291094 DOI: 10.1021/acs.analchem.9b00379] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Hongding Zhang
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Kun Zhang
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Yuanyuan Yao
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Yujie Liu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Ji Ji
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Xuedong Huang
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Jianwei Liu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| | - Baohong Liu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers and Institute of Biomedical Sciences, Fudan University, Shanghai 200433, P. R. China
| |
Collapse
|
10
|
Croop B, Han KY. Facile single-molecule pull-down assay for analysis of endogenous proteins. Phys Biol 2019; 16:035002. [PMID: 30769341 DOI: 10.1088/1478-3975/ab0792] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
The single-molecule pull-down (SiMPull) assay analyzes molecular complexes in physiological conditions from cell or tissue lysates. Currently the approach requires a lengthy sample preparation process, which has largely prevented the widespread adoption of this technique in bioanalysis. Here, we present a simplified SiMPull assay based upon dichlorodimethylsilane-Tween-20 passivation and F(ab) fragment labeling. Our passivation is a much shorter process than the standard polyethylene glycol passivation used in most single-molecule studies. The use of F(ab) fragments for indirect fluorescent labeling rather than divalent F(ab')2 or whole IgG antibodies allows for the pre-incubation of the detection antibodies, reducing the sample preparation time for single-molecule immunoprecipitation samples. We examine the applicability of our approach to recombinant proteins and endogenous proteins from mammalian cell lysates.
Collapse
Affiliation(s)
- Benjamin Croop
- CREOL, The College of Optics and Photonics, University of Central Florida, Orlando, FL, United States of America
| | | |
Collapse
|