1
|
Dos Reis RA, Boudier A, Piquard F, Piereti JC, Seabra AB, Clarot I. Nitric oxide detection by electrochemistry selective probe: calibration in the study environment is mandatory. Nitric Oxide 2025; 157:46-54. [PMID: 40258469 DOI: 10.1016/j.niox.2025.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2025] [Revised: 03/27/2025] [Accepted: 04/19/2025] [Indexed: 04/23/2025]
Abstract
Nitric oxide (NO) plays a crucial role in various physiological processes, making its detection and controlled release significant for both therapeutic and environmental contexts. Electrochemical sensors are widely used for NO detection due to their high sensitivity and real-time monitoring capabilities. However, challenges such as interference from other gasotransmitters, sensor degradation, and calibration difficulties-especially in complex biological matrices-hinder accurate NO measurement. This review discusses recent advancements in electrochemical NO detection, with a focus on the impact of complex biological matrices, calibration strategies, and sensor designs. The release of NO from nanoparticles, such as S-nitrosoglutathione (GSNO)-encapsulating chitosan nanoparticles, is used as a case study for improving NO detection accuracy. Future innovations in sensor technology and nanoparticle design are expected to expand the applicability of NO detection in personalized medicine and environmental monitoring.
Collapse
Affiliation(s)
- Roberta Albino Dos Reis
- Université de Lorraine, CITHEFOR, F-54000, Nancy, France; Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Santo André 09210-580, Brazil
| | - Ariane Boudier
- Université de Lorraine, CITHEFOR, F-54000, Nancy, France; Université de Lorraine, CNRS, LRGP, F-54000, Nancy, France; Institut Universitaire de France (IUF), France
| | | | - Joana C Piereti
- Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Santo André 09210-580, Brazil
| | - Amedea B Seabra
- Center for Natural and Human Sciences (CCNH), Federal University of ABC (UFABC), Santo André 09210-580, Brazil
| | - Igor Clarot
- Université de Lorraine, CITHEFOR, F-54000, Nancy, France; Université de Lorraine, CNRS, LRGP, F-54000, Nancy, France.
| |
Collapse
|
2
|
Shang H, Zhang X, Ding M, Zhang A, Du J, Zhang R. Smartphone Imaging Device for Multimodal Detection of Hydrogen Sulfide Using Cu-Doped MOF Sensors. ACS APPLIED MATERIALS & INTERFACES 2024; 16:30890-30899. [PMID: 38843539 DOI: 10.1021/acsami.4c05021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
Multimodal sensing platforms may offer reliable, fast results, but it is still challenging to incorporate biosensors with high discriminating ability in complex biological samples. Herein, we established a highly sensitive dual colorimetric/electrochemical monitoring approach for the detection of hydrogen sulfide (H2S) utilizing Cu-doped In-based metal-organic frameworks (Cu/In-MOFs) combined with a versatile color selector software-based smartphone imaging device. H2S can result in the enhancement of the electrochemical signal because of the electroactive substance copper sulfide (CuxS), the decrease of the colorimetric signal of the characteristic absorption response caused by the strong coordination effect on Cu/In-MOFs, and the obvious changes of red-green-blue (RGB) values of images acquired via an intelligent smartphone. Attractively, the Cu/In-MOFs-based multimodal detection guarantees precise and sensitive detection of H2S with triple-signal detection limits of 0.096 μM (electrochemical signals), 0.098 μM (colorimetric signals), and 0.099 μM (smartphone signals) and an outstanding linear response. This analytical toolkit provides an idea for fabricating a robust, sensitive, tolerant matrix and reliable sensing platform for rapidly monitoring H2S in clinical disease diagnosis and visual supervision.
Collapse
Affiliation(s)
- Hongyuan Shang
- Department of Radiology, Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Taiyuan 030032, China
- College of Pharmacy, Shanxi Medical University, Taiyuan 030001, China
| | - Xiaofei Zhang
- College of Pharmacy, Shanxi Medical University, Taiyuan 030001, China
| | - Meili Ding
- College of Pharmacy, Shanxi Medical University, Taiyuan 030001, China
| | - Aiping Zhang
- College of Pharmacy, Shanxi Medical University, Taiyuan 030001, China
| | - Jinwen Du
- Stomatological Department, Taiyuan Municipal No. 2 People's Hospital, Taiyuan 030002, China
| | - Ruiping Zhang
- The Radiology Department of Shanxi Provincial People's Hospital, The Fifth Hospital of Shanxi Medical University, Taiyuan 030001, China
| |
Collapse
|
3
|
Ramesh A, Sahu PK, Duvvuri S, Subrahmanyam C. MnCo 2O 4 Spinel Nanorods for Highly Sensitive Electrochemical Detection of Nitrite. Inorg Chem 2024; 63:9941-9952. [PMID: 38738811 DOI: 10.1021/acs.inorgchem.4c01012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
The rational design of nitrite sensors has attracted significant research interest due to their widespread use and the associated risks of methemoglobinemia and carcinogenicity. The undisclosed nitrite-sensing performance of the spinel cobaltite MnCo2O4 (MCO) prepared by an oxalate-assisted coprecipitation method is reported in this study. Spectroscopy and microscopy investigations revealed the formation of uniform MCO nanorods with a high aspect ratio. The electrocatalytic nitrite oxidation at the MCO-coated glassy carbon electrode (MCO/GCE) indicated the promising performance of the synthesized material for nitrite sensing. MCO/GCE detects nitrite in a concentration range of 5 μM to 3 mM and has a limit of detection of 0.95 μM with a higher sensitivity of 857 μA mM-1 cm-2 in a response time of 4 s. In MCO, the mixed-valence states of Co2+/Co3+ confer a high electrical conductivity, and higher valent redox couples of Mn and Co impart remarkable electrocatalytic activity toward nitrite oxidation. MCO spinel undergoes facile and ultrafast faradaic reactions to mediate nitrite oxidation. Additionally, the mesopores of MCO nanorods facilitate the rapid diffusion of electrolyte and nitrite ions. Employing the electrode in sensing nitrite in milk, lake, and tap water samples further validates its potential application in real-life testing. MCO spinel nanorods showcase promising scope for utilization in the electrochemical sensing of nitrite and inspire further exploration of transition-metal oxide-based mixed-spinel materials.
Collapse
Affiliation(s)
- Asha Ramesh
- Department of Chemistry, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India
| | - Pravat Kumar Sahu
- Department of Chemistry, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India
| | - Suryakala Duvvuri
- Department of Chemistry, GITAM University, Visakhapatnam, Andhra Pradesh 530045, India
| | - Ch Subrahmanyam
- Department of Chemistry, Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India
| |
Collapse
|
4
|
Zhou Y, Yin H, Li J, Shao K, Dong H, Ling C, Wang X, Xu M. Construction of poly (ionic liquid)-derived gold/silver alloy@nitrogen-doped carbon shell and its application for ratiometric electrochemical detection of nitric oxide. Talanta 2024; 272:125839. [PMID: 38428134 DOI: 10.1016/j.talanta.2024.125839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/25/2024] [Accepted: 02/26/2024] [Indexed: 03/03/2024]
Abstract
A nitrogen-doped carbon shell loaded with a gold and silver alloy (Au/Ag@NCS) was constructed for highly sensitive electrochemical detection of NO. The Au/Ag@NCS material was prepared by use of SiO2 particles as a template to polymerize imidazolium-based ionic liquids loaded with gold and silver salts, and subsequent carbonization treatment and template removal. The hollow structure of the carbon material acted as a carrier for electrochemical sensing, offering high specific surface area, large pore capacity, robust electron conductivity, and excellent mechanical stability. The inclusion of gold in the composite enhanced its catalytic and sensing capabilities, while silver oxidation was employed as a reference signal for accurate detection. By utilization of the Au/Ag@NCS-modified electrode, a wide detection range from 0.5 nM to 1.05 μM with a low detection limit of 0.32 nM was achieved for NO detection. The electrochemical sensor also exhibited high selectivity and excellent stability. The fabricated sensor was further utilized to explore the release of NO from breast cancer cells, revealing that the electrochemical platform could be regarded as an important method to study the daily tests of NO in clinical application.
Collapse
Affiliation(s)
- Yanli Zhou
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, China; School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, China.
| | - Hewen Yin
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, China
| | - Junru Li
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, China
| | - Kexian Shao
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, China
| | - Hui Dong
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, China
| | - Cuixia Ling
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, China
| | - Xiaobing Wang
- School of Chemistry and Chemical Engineering, Henan Normal University, Xinxiang, 453007, China
| | - Maotian Xu
- Henan Key Laboratory of Biomolecular Recognition and Sensing, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, China.
| |
Collapse
|