1
|
Siegel J, Kim S, Fortman M, Wan C, Kats MA, Hon PWC, Sweatlock L, Jang MS, Brar VW. Electrostatic steering of thermal emission with active metasurface control of delocalized modes. Nat Commun 2024; 15:3376. [PMID: 38643246 PMCID: PMC11032313 DOI: 10.1038/s41467-024-47229-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 03/25/2024] [Indexed: 04/22/2024] Open
Abstract
We theoretically describe and experimentally demonstrate a graphene-integrated metasurface structure that enables electrically-tunable directional control of thermal emission. This device consists of a dielectric spacer that acts as a Fabry-Perot resonator supporting long-range delocalized modes bounded on one side by an electrostatically tunable metal-graphene metasurface. By varying the Fermi level of the graphene, the accumulated phase of the Fabry-Perot mode is shifted, which changes the direction of absorption and emission at a fixed frequency. We directly measure the frequency- and angle-dependent emissivity of the thermal emission from a fabricated device heated to 250 °C. Our results show that electrostatic control allows the thermal emission at 6.61 μm to be continuously steered over 16°, with a peak emissivity maintained above 0.9. We analyze the dynamic behavior of the thermal emission steerer theoretically using a Fano interference model, and use the model to design optimized thermal steerer structures.
Collapse
Affiliation(s)
- Joel Siegel
- Department of Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Shinho Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Margaret Fortman
- Department of Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Chenghao Wan
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Mikhail A Kats
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | | | | | - Min Seok Jang
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea.
| | - Victor Watson Brar
- Department of Physics, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
2
|
Yamazaki Y, Hitomi T, Homma C, Rungreungthanapol T, Tanaka M, Yamada K, Hamasaki H, Sugizaki Y, Isobayashi A, Tomizawa H, Okochi M, Hayamizu Y. Enantioselective Detection of Gaseous Odorants with Peptide-Graphene Sensors Operating in Humid Environments. ACS APPLIED MATERIALS & INTERFACES 2024; 16:18564-18573. [PMID: 38567738 DOI: 10.1021/acsami.4c01177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
Replicating the sense of smell presents an ongoing challenge in the development of biomimetic devices. Olfactory receptors exhibit remarkable discriminatory abilities, including the enantioselective detection of individual odorant molecules. Graphene has emerged as a promising material for biomimetic electronic devices due to its unique electrical properties and exceptional sensitivity. However, the efficient detection of nonpolar odor molecules using transistor-based graphene sensors in a gas phase in environmental conditions remains challenging due to high sensitivity to water vapor. This limitation has impeded the practical development of gas-phase graphene odor sensors capable of selective detection, particularly in humid environments. In this study, we address this challenge by introducing peptide-functionalized graphene sensors that effectively mitigate undesired responses to changes in humidity. Additionally, we demonstrate the significant role of humidity in facilitating the selective detection of odorant molecules by the peptides. These peptides, designed to mimic a fruit fly olfactory receptor, spontaneously assemble into a monomolecular layer on graphene, enabling precise and specific odorant detection. The developed sensors exhibit notable enantioselectivity, achieving a remarkable 35-fold signal contrast between d- and l-limonene. Furthermore, these sensors display distinct responses to various other biogenic volatile organic compounds, demonstrating their versatility as robust tools for odor detection. By acting as both a bioprobe and an electrical signal amplifier, the peptide layer represents a novel and effective strategy to achieve selective odorant detection under normal atmospheric conditions using graphene sensors. This study offers valuable insights into the development of practical odor-sensing technologies with potential applications in diverse fields.
Collapse
Affiliation(s)
- Yui Yamazaki
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| | - Tatsuru Hitomi
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| | - Chishu Homma
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| | - Tharatorn Rungreungthanapol
- Department of Chemical Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| | - Masayoshi Tanaka
- Department of Chemical Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| | - Kou Yamada
- Corporate Research & Development Center, Toshiba Corporation, 1, Komukai-Toshiba-Cho, Saiwai-ku, Kawasaki 212-8582, Japan
| | - Hiroshi Hamasaki
- Corporate Research & Development Center, Toshiba Corporation, 1, Komukai-Toshiba-Cho, Saiwai-ku, Kawasaki 212-8582, Japan
| | - Yoshiaki Sugizaki
- Corporate Research & Development Center, Toshiba Corporation, 1, Komukai-Toshiba-Cho, Saiwai-ku, Kawasaki 212-8582, Japan
| | - Atsunobu Isobayashi
- Corporate Research & Development Center, Toshiba Corporation, 1, Komukai-Toshiba-Cho, Saiwai-ku, Kawasaki 212-8582, Japan
| | - Hideyuki Tomizawa
- Corporate Research & Development Center, Toshiba Corporation, 1, Komukai-Toshiba-Cho, Saiwai-ku, Kawasaki 212-8582, Japan
| | - Mina Okochi
- Department of Chemical Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| | - Yuhei Hayamizu
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguroku, Tokyo 152-8550, Japan
| |
Collapse
|
3
|
Jing Q, Liu J, Wang H, Wang Y, Xue H, Ren S, Wang W, Zhang X, Xu Z, Fu W. Ultrasensitive Biochemical Sensing Platform Enabled by Directly Grown Graphene on Insulator. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023:e2305363. [PMID: 38105346 DOI: 10.1002/smll.202305363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 11/06/2023] [Indexed: 12/19/2023]
Abstract
To fabricate label-free and rapid-resulting semiconducting biosensor devices incorporating graphene, it is pertinent to directly grow uniform graphene films on technologically important dielectric and semiconducting substrates. However, it has long been intuitively believed that the nonideal disordered structures formed during direct growth, and the resulted inferior electrical properties will inevitably lead to deteriorated sensing performance. Here, graphene biosensor chips are constructed based on direct plasma-enhanced chemical vapor deposition (PECVD) grown graphene on a 4-inch silicon wafer with excellent film uniformity and high yield. To surprise, optimal operations of graphene biosensors permit ultrasensitive detection of SARS-CoV-2 virus nucleocapsid protein with dilutions down to sub-femtomolar concentrations. Such impressive limit of detection (LOD) is comparable to or even outperforms that of the state-of-the-art biosensor devices based on high-quality graphene. Further noise spectral characterizations and analysis confirms that the LOD is limited by molecular diffusion and/or known interference signals such as drift and instability of the sensors, rather than the electrical merits of the graphene devices along. Hence, result sheds light on processing directly grown PECVD graphene into high-performance sensor devices with important economic benefits and social significance.
Collapse
Affiliation(s)
- Qiushi Jing
- School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China
| | - Junjiang Liu
- Songshan Lake Materials Laboratory, Dongguan, 523808, China
| | - Huanming Wang
- Songshan Lake Materials Laboratory, Dongguan, 523808, China
| | - Yanli Wang
- Songshan Lake Materials Laboratory, Dongguan, 523808, China
| | - Honglei Xue
- School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China
| | - Shan Ren
- Beijing Youan Hospital, Capital Medical University, Beijing, 100069, China
| | - Wenjing Wang
- Beijing Youan Hospital, Capital Medical University, Beijing, 100069, China
| | - Xiaoyan Zhang
- School of Pharmaceutical Sciences, Capital Medical University, Beijing, 100069, China
| | - Zhi Xu
- Songshan Lake Materials Laboratory, Dongguan, 523808, China
| | - Wangyang Fu
- School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
4
|
Nezval D, Bartošík M, Mach J, Švarc V, Konečný M, Piastek J, Špaček O, Šikola T. DFT study of water on graphene: Synergistic effect of multilayer p-doping. J Chem Phys 2023; 159:214710. [PMID: 38047516 DOI: 10.1063/5.0161160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 11/07/2023] [Indexed: 12/05/2023] Open
Abstract
Recent experiments related to a study concerning the adsorption of water on graphene have demonstrated the p-doping of graphene, although most of the ab initio calculations predict nearly zero doping. To shed more light on this problem, we have carried out van der Waals density functional theory calculations of water on graphene for both individual water molecules and continuous water layers with coverage ranging from one to eight monolayers. Furthermore, we have paid attention to the influence of the water molecule orientation toward graphene on its doping properties. In this article, we present the results of the band structure and the Bader charge analysis, showing the p-doping of graphene can be synergistically enhanced by putting 4-8 layers of an ice-like water structure on graphene having the water molecules oriented with oxygen atoms toward graphene.
Collapse
Affiliation(s)
- D Nezval
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - M Bartošík
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
- Department of Physics and Materials Engineering, Faculty of Technology, Tomas Bata University in Zlín, Vavrečkova 275, 760 01 Zlín, Czech Republic
| | - J Mach
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - V Švarc
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - M Konečný
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - J Piastek
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - O Špaček
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| | - T Šikola
- Institute of Physical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
- Central European Institute of Technology, Brno University of Technology, Purkyňova 656/123, 612 00 Brno, Czech Republic
| |
Collapse
|
5
|
Wang J, Chen D, Huang W, Yang N, Yuan Q, Yang Y. Aptamer-functionalized field-effect transistor biosensors for disease diagnosis and environmental monitoring. EXPLORATION (BEIJING, CHINA) 2023; 3:20210027. [PMID: 37933385 PMCID: PMC10624392 DOI: 10.1002/exp.20210027] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Accepted: 03/10/2023] [Indexed: 11/08/2023]
Abstract
Nano-biosensors that are composed of recognition molecules and nanomaterials have been extensively utilized in disease diagnosis, health management, and environmental monitoring. As a type of nano-biosensors, molecular specificity field-effect transistor (FET) biosensors with signal amplification capability exhibit prominent advantages including fast response speed, ease of miniaturization, and integration, promising their high sensitivity for molecules detection and identification. With intrinsic characteristics of high stability and structural tunability, aptamer has become one of the most commonly applied biological recognition units in the FET sensing fields. This review summarizes the recent progress of FET biosensors based on aptamer functionalized nanomaterials in medical diagnosis and environmental monitoring. The structure, sensing principles, preparation methods, and functionalization strategies of aptamer modified FET biosensors were comprehensively summarized. The relationship between structure and sensing performance of FET biosensors was reviewed. Furthermore, the challenges and future perspectives of FET biosensors were also discussed, so as to provide support for the future development of efficient healthcare management and environmental monitoring devices.
Collapse
Affiliation(s)
- Jingfeng Wang
- College of Chemistry and Molecular Sciences, Institute of Molecular MedicineRenmin Hospital of Wuhan University, School of Microelectronics, Wuhan UniversityWuhanChina
| | - Duo Chen
- College of Chemistry and Molecular Sciences, Institute of Molecular MedicineRenmin Hospital of Wuhan University, School of Microelectronics, Wuhan UniversityWuhanChina
| | - Wanting Huang
- College of Chemistry and Molecular Sciences, Institute of Molecular MedicineRenmin Hospital of Wuhan University, School of Microelectronics, Wuhan UniversityWuhanChina
| | - Nianjun Yang
- Department of Chemistry, Insititute of Materials ResearchHasselt UniversityHasseltBelgium
| | - Quan Yuan
- Molecular Science and Biomedicine Laboratory (MBL), State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical EngineeringHunan UniversityChangshaChina
| | - Yanbing Yang
- College of Chemistry and Molecular Sciences, Institute of Molecular MedicineRenmin Hospital of Wuhan University, School of Microelectronics, Wuhan UniversityWuhanChina
| |
Collapse
|
6
|
Shahdeo D, Chauhan N, Majumdar A, Ghosh A, Gandhi S. Graphene-Based Field-Effect Transistor for Ultrasensitive Immunosensing of SARS-CoV-2 Spike S1 Antigen. ACS APPLIED BIO MATERIALS 2022; 5:3563-3572. [PMID: 35775242 PMCID: PMC9274923 DOI: 10.1021/acsabm.2c00503] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Coronavirus disease (COVID-19) is an infectious disease that has posed a global health challenge caused by the SARS-CoV-2 virus. Early management and diagnosis of SARS-CoV-2 are crucial for the timely treatment, traceability, and reduction of viral spread. We have developed a rapid method using a Graphene-based Field-Effect Transistor (Gr-FET) for the ultrasensitive detection of SARS-CoV-2 Spike S1 antigen (S1-Ag). The in-house developed antispike S1 antibody (S1-Ab) was covalently immobilized on the surface of a carboxy functionalized graphene channel using carbodiimide chemistry. Ultraviolet-visible spectroscopy, Fourier-Transform Infrared Spectroscopy, X-ray Photoelectron Spectroscopy (XPS), Atomic Force Microscopy (AFM), Optical Microscopy, Raman Spectroscopy, Scanning Electron Microscopy (SEM), Enzyme-Linked Immunosorbent Assays (ELISA), and device stability studies were conducted to characterize the bioconjugation and fabrication process of Gr-FET. In addition, the electrical response of the device was evaluated by monitoring the change in resistance caused by Ag-Ab interaction in real time. For S1-Ag, our Gr-FET devices were tested in the range of 1 fM to 1 μM with a limit of detection of 10 fM in the standard buffer. The fabricated devices are highly sensitive, specific, and capable of detecting low levels of S1-Ag.
Collapse
Affiliation(s)
- Deepshikha Shahdeo
- DBT-National
Institute of Animal Biotechnology (DBT-NIAB), Hyderabad 500032, Telangana, India
| | - Neha Chauhan
- Department
of Physics, Indian Institute of Science
(IISc), Bangalore 560012, India
- The
Solid State and Structural Chemistry Unit, Indian Institute of Science, Bangalore 560012, India
| | - Aniket Majumdar
- Department
of Physics, Indian Institute of Science
(IISc), Bangalore 560012, India
| | - Arindam Ghosh
- Department
of Physics, Indian Institute of Science
(IISc), Bangalore 560012, India
- Centre
for Nano Science and Engineering (CeNSE), Indian Institute of Science (IISc), Bangalore 560012, India
| | - Sonu Gandhi
- DBT-National
Institute of Animal Biotechnology (DBT-NIAB), Hyderabad 500032, Telangana, India
| |
Collapse
|
7
|
Pizzocchero F, Jessen BS, Gammelgaard L, Andryieuski A, Whelan PR, Shivayogimath A, Caridad JM, Kling J, Petrone N, Tang PT, Malureanu R, Hone J, Booth TJ, Lavrinenko A, Bøggild P. Chemical Vapor-Deposited Graphene on Ultraflat Copper Foils for van der Waals Hetero-Assembly. ACS OMEGA 2022; 7:22626-22632. [PMID: 35811885 PMCID: PMC9260747 DOI: 10.1021/acsomega.2c01946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 06/09/2022] [Indexed: 06/15/2023]
Abstract
The purity and morphology of the copper surface is important for the synthesis of high-quality, large-grained graphene by chemical vapor deposition. We find that atomically smooth copper foils-fabricated by physical vapor deposition and subsequent electroplating of copper on silicon wafer templates-exhibit strongly reduced surface roughness after the annealing of the copper catalyst, and correspondingly lower nucleation and defect density of the graphene film, when compared to commercial cold-rolled copper foils. The "ultrafoils"-ultraflat foils-facilitate easier dry pickup and encapsulation of graphene by hexagonal boron nitride, which we believe is due to the lower roughness of the catalyst surface promoting a conformal interface and subsequent stronger van der Waals adhesion between graphene and hexagonal boron nitride.
Collapse
Affiliation(s)
- Filippo Pizzocchero
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
| | - Bjarke S. Jessen
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
- Department
of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Lene Gammelgaard
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
| | - Andrei Andryieuski
- DTU
Electro, Technical University of Denmark, Ørsteds pl. 343, Kongens Lyngby 2800 Denmark
| | - Patrick R. Whelan
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
- Department
of Materials and Production, Aalborg University, Skjernvej 4A, Aalborg 9220, Denmark
| | - Abhay Shivayogimath
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
| | - José M. Caridad
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
- Department
of Applied Physics and USAL NanoLab, University
of Salamanca, 37008 Salamanca, Spain
| | - Jens Kling
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Nanolab, Technical University of Denmark, Fysikvej 307, Kongens Lyngby 2800, Denmark
| | - Nicholas Petrone
- Department
of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Peter T. Tang
- IPU,
Danmarks Tekniske Universitet, Produktionstorvet 425, Kongens Lyngby 2800 Denmark
| | - Radu Malureanu
- DTU
Electro, Technical University of Denmark, Ørsteds pl. 343, Kongens Lyngby 2800 Denmark
| | - James Hone
- Department
of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Timothy J. Booth
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
| | - Andrei Lavrinenko
- DTU
Electro, Technical University of Denmark, Ørsteds pl. 343, Kongens Lyngby 2800 Denmark
| | - Peter Bøggild
- CNG—Center
of Nanostructured Graphene, Kongens
Lyngby 2800 Denmark
- DTU
Physics, Technical University of Denmark, Building 309, Kongens Lyngb 2800 Denmark
| |
Collapse
|
8
|
Lu YX, Lin CT, Tsai MH, Lin KC. Review-Hysteresis in Carbon Nano-Structure Field Effect Transistor. MICROMACHINES 2022; 13:mi13040509. [PMID: 35457813 PMCID: PMC9029578 DOI: 10.3390/mi13040509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 03/18/2022] [Accepted: 03/22/2022] [Indexed: 11/16/2022]
Abstract
In recent decades, the research of nano-structure devices (e.g., carbon nanotube and graphene) has experienced rapid growth. These materials have supreme electronic, thermal, optical and mechanical properties and have received widespread concern in different fields. It is worth noting that gate hysteresis behavior of field effect transistors can always be found in ambient conditions, which may influence the transmission appearance. Many researchers have put forward various views on this question. Here, we summarize and discuss the mechanisms behind hysteresis, different influencing factors and improvement methods which help decrease or eliminate unevenness and asymmetry.
Collapse
|
9
|
Yang X, Chi H, Tian Y, Li T, Wang Y. Research Progress of Graphene and Its Derivatives towards Exhaled Breath Analysis. BIOSENSORS 2022; 12:bios12020048. [PMID: 35200309 PMCID: PMC8869631 DOI: 10.3390/bios12020048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 01/13/2022] [Accepted: 01/15/2022] [Indexed: 11/16/2022]
Abstract
The metabolic process of the human body produces a large number of gaseous biomarkers. The tracking and monitoring of certain diseases can be achieved through the detection of these markers. Due to the superior specific surface area, large functional groups, good optical transparency, conductivity and interlayer spacing, graphene, and its derivatives are widely used in gas sensing. Herein, the development of graphene and its derivatives in gas-phase biomarker detection was reviewed in terms of the detection principle and the latest detection methods and applications in several common gases, etc. Finally, we summarized the commonly used materials, preparation methods, response mechanisms for NO, NH3, H2S, and volatile organic gas VOCs, and other gas detection, and proposed the challenges and prospective applications in this field.
Collapse
|
10
|
Gao J, Wang C, Chu Y, Han Y, Gao Y, Wang Y, Wang C, Liu H, Han L, Zhang Y. Graphene oxide-graphene Van der Waals heterostructure transistor biosensor for SARS-CoV-2 protein detection. Talanta 2021; 240:123197. [PMID: 34996016 PMCID: PMC8719368 DOI: 10.1016/j.talanta.2021.123197] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 12/27/2021] [Accepted: 12/29/2021] [Indexed: 12/27/2022]
Abstract
The current outbreaking of the coronavirus SARS-CoV-2 pandemic threatens global health and has caused serious concern. Currently there is no specific drug against SARS-CoV-2, therefore, a fast and accurate diagnosis method is an urgent need for the diagnosis, timely treatment and infection control of COVID-19 pandemic. In this work, we developed a field effect transistor (FET) biosensor based on graphene oxide-graphene (GO/Gr) van der Waals heterostructure for selective and ultrasensitive SARS-CoV-2 proteins detection. The GO/Gr van der Waals heterostructure was in-situ formed in the microfluidic channel through π-π stacking. The developed biosensor is capable of SARS-CoV-2 proteins detection within 20 min in the large dynamic range from 10 fg/mL to 100 pg/mL with the limit of detection of as low as ∼8 fg/mL, which shows ∼3 × sensitivity enhancement compared with Gr-FET biosensor. The performance enhancement mechanism was studied based on the transistor-based biosensing theory and experimental results, which is mainly attributed to the enhanced SARS-CoV-2 capture antibody immobilization density due to the introduction of the GO layer on the graphene surface. The spiked SARS-CoV-2 protein samples in throat swab buffer solution were tested to confirm the practical application of the biosensor for SARS-CoV-2 proteins detection. The results indicated that the developed GO/Gr van der Waals heterostructure FET biosensor has strong selectivity and high sensitivity, providing a potential method for SARS-CoV-2 fast and accurate detection.
Collapse
Affiliation(s)
- Jianwei Gao
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Chunhua Wang
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Yujin Chu
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Yingkuan Han
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Yakun Gao
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Yanhao Wang
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Chao Wang
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Hong Liu
- State Key Laboratory of Crystal Materials, Shandong University, Jinan, Shandong, 250100, China.
| | - Lin Han
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| | - Yu Zhang
- Institute of Marine Science and Technology, Shandong University, Qingdao, 266237, China.
| |
Collapse
|
11
|
Printable graphene BioFETs for DNA quantification in Lab-on-PCB microsystems. Sci Rep 2021; 11:9815. [PMID: 33972649 PMCID: PMC8111018 DOI: 10.1038/s41598-021-89367-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 04/26/2021] [Indexed: 01/09/2023] Open
Abstract
Lab-on-Chip is a technology that aims to transform the Point-of-Care (PoC) diagnostics field; nonetheless a commercial production compatible technology is yet to be established. Lab-on-Printed Circuit Board (Lab-on-PCB) is currently considered as a promising candidate technology for cost-aware but simultaneously high specification applications, requiring multi-component microsystem implementations, due to its inherent compatibility with electronics and the long-standing industrial manufacturing basis. In this work, we demonstrate the first electrolyte gated field-effect transistor (FET) DNA biosensor implemented on commercially fabricated PCB in a planar layout. Graphene ink was drop-casted to form the transistor channel and PNA probes were immobilized on the graphene channel, enabling label-free DNA detection. It is shown that the sensor can selectively detect the complementary DNA sequence, following a fully inkjet-printing compatible manufacturing process. The results demonstrate the potential for the effortless integration of FET sensors into Lab-on-PCB diagnostic platforms, paving the way for even higher sensitivity quantification than the current Lab-on-PCB state-of-the-art of passive electrode electrochemical sensing. The substitution of such biosensors with our presented FET structures, promises further reduction of the time-to-result in microsystems combining sequential DNA amplification and detection modules to few minutes, since much fewer amplification cycles are required even for low-abundance nucleic acid targets.
Collapse
|