1
|
Xu W, Cao Y, Shi H, Jia X, Zheng Y, Tan Z, Zhao R, Wu H. Skin-interfaced sweat monitoring patch constructed by flexible microfluidic capillary pump and Cu-MOF sensitized electrochemical sensor. Talanta 2025; 291:127895. [PMID: 40056654 DOI: 10.1016/j.talanta.2025.127895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2025] [Revised: 02/21/2025] [Accepted: 03/03/2025] [Indexed: 03/10/2025]
Abstract
The limitations of skin-interfaced sweat monitoring are mainly reflected in the effective collection of sweat and the high sensitivity of the detection. This work proposes a new type of sweat monitoring patch based on a flexible microfluidic chip fabricated by a capillary pump and a copper-based metal-based organic framework (Cu-MOF) sensitized electrochemical sensor. The sweat in the microchannel is driven by a capillary pump to ensure the smooth collection and transportation. The sweat collection channel adopts the ingenious design of wedge-shaped structure, which helps to spontaneously generate Laplacian forces to direct sweat to the detection area. The detection area combines upper and lower capillary pumps, which aim to improve the efficiency of sweat collection. The controllable preparation of Cu-MOF was realized by using a micro-mixer, and the glucose sensor was prepared with it as the probe. The Cu-MOF/PANI layered electrode was prepared, which effectively improved the sensitivity of glucose detection and achieved a significant detection limit of 2.84 μM in the concentration range of 0-1 mM. Sodium and potassium selective electrode were also integrated into a unified screen-printed electrode, and a portable electrochemical detection module, a Bluetooth transmission module, and a mobile phone receiving application were developed. The sweat monitoring patch shows potential in applications such as sports performance monitoring, healthcare, and personalized medicine, opening new avenues for non-invasive health monitoring and early disease detection.
Collapse
Affiliation(s)
- Weizheng Xu
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Yu Cao
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Huanhuan Shi
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China.
| | - Xuanhao Jia
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Yun Zheng
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Zhongjian Tan
- Department of Biomedical Engineering, School of Instrumentation and Optical Engineering, Nanchang Hangkong University, Nanchang, Jiangxi, 330063, People's Republic of China
| | - Rui Zhao
- Department of Clinical Laboratory, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, 330052, People's Republic of China
| | - Hongwen Wu
- Jiangxi Provincial Key Laboratory of Prevention and Treatment of Infectious Diseases, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, Jiangxi, 330052, People's Republic of China.
| |
Collapse
|
2
|
Berkheimer ZA, Tahir A, Nordin GP, Paixão TRLC, Woolley AT, do Nascimento GHM, de Araujo WR, Pradela-Filho LA. Extruded filament electrodes for lactate biosensing in continuous-injection paper-based microfluidic devices. Biosens Bioelectron 2025; 278:117390. [PMID: 40128136 DOI: 10.1016/j.bios.2025.117390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2025] [Revised: 02/14/2025] [Accepted: 03/17/2025] [Indexed: 03/26/2025]
Abstract
Versatile electrodes were templated into poly (methyl methacrylate) (PMMA) molds with a 3D printing pen and commercial carbon black filament. The working electrodes (WE) were modified with Prussian Blue (PB), lactate oxidase (LOx)/chitosan solution, and Nafion. Under optimized modification conditions, a 3-electrode thermoplastic chip was integrated with paper-based analytical devices (μPADs). This integration was conducted by attaching a circular piece of paper to the 3-electrode thermoplastic chip, enclosing the system with a PMMA cover and clamps. The injections of the analyte solution were performed at the center of the μPADs, where the WE is positioned. The injections generated a radial flow during the analysis, eliminating the need for channels containing hydrophobic barriers to constrain the solution. This system also allows sequential/multiple injections of analyte solution, providing rapid responses in peak format. The μPADs were initially characterized with a food dye solution and ferricyanide as a redox probe. Increasing the pore size of the paper substrates increased the flow rate of the μPADs, providing sharper and more intense transient signals. In addition, increasing the injection volume produced broader peaks, also limiting the number of injections. The proposed system provided a linear range from 0.5 to 4 mmol L-1 lactate. Requiring only 2 μL of the sample, the analytical applicability of the μPADs was further demonstrated for lactate determination through discrete sampling of real sweat. Therefore, this work brings a straightforward approach to fabricating μPADs for lactate quantification, opening possibilities for new sensing applications demanding sample volumes as small as a few μL.
Collapse
Affiliation(s)
- Zachary A Berkheimer
- Department of Chemistry and Biochemistry, Brigham Young University, 84602, Provo, UT, USA
| | - Anum Tahir
- Department of Chemistry and Biochemistry, Brigham Young University, 84602, Provo, UT, USA
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, 84602, Provo, UT, USA
| | - Thiago R L C Paixão
- Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, 05508-000, São Paulo, SP, Brazil.
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, 84602, Provo, UT, USA
| | - Guida H M do Nascimento
- Institute of Chemistry, Department of Analytical Chemistry, State University of Campinas, 13083-970, Campinas, SP, Brazil
| | - William R de Araujo
- Institute of Chemistry, Department of Analytical Chemistry, State University of Campinas, 13083-970, Campinas, SP, Brazil
| | - Lauro A Pradela-Filho
- Department of Chemistry and Biochemistry, Brigham Young University, 84602, Provo, UT, USA; Institute of Chemistry, Department of Fundamental Chemistry, University of São Paulo, 05508-000, São Paulo, SP, Brazil.
| |
Collapse
|
3
|
Chen B, Gao J, Sun H, Chen Z, Qiu X. Wearable SERS devices in health management: Challenges and prospects. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 334:125957. [PMID: 40024086 DOI: 10.1016/j.saa.2025.125957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2025] [Revised: 02/19/2025] [Accepted: 02/24/2025] [Indexed: 03/04/2025]
Abstract
Surface-Enhanced Raman Scattering (SERS) is an advanced analytical technique renowned for its heightened sensitivity in detecting molecular vibrations. Its integration into wearable technologies facilitates the monitoring of biofluids, such as sweat and tears, enabling continuous, non-invasive, real-time analysis of human chemical and biomolecular processes. This capability underscores its significant potential for early disease detection and the advancement of personalized medicine. SERS has attracted considerable research attention in the fields of wearable flexible sensing and point-of-care testing (POCT) within medical diagnostics. Nonetheless, the integration of SERS with wearable technology presents several challenges, including device miniaturization, reliable biofluid sampling, user comfort, biocompatibility, and data interpretation. The ongoing advancements in nanotechnology and artificial intelligence are instrumental in addressing these challenges. This review provides a comprehensive analysis of design strategies for wearable SERS sensors and explores their applications within this domain. Finally, it addresses the current challenges in this area and the future prospects of combining SERS wearable sensors with other portable health monitoring systems for POCT medical diagnostics. Wearable SERS is a promising innovation in future healthcare, potentially enhancing individual health outcomes and reducing healthcare costs by fostering preventive health management approaches.
Collapse
Affiliation(s)
- Biqing Chen
- Gynaecology and Obstetrics, The Second Affiliated Hospital of Harbin Medical University, Harbin Medical University, Heilongjiang 150081, PR China.
| | - Jiayin Gao
- Gynaecology and Obstetrics, The Second Affiliated Hospital of Harbin Medical University, Harbin Medical University, Heilongjiang 150081, PR China
| | - Haizhu Sun
- Gynaecology and Obstetrics, The Second Affiliated Hospital of Harbin Medical University, Harbin Medical University, Heilongjiang 150081, PR China
| | - Zhi Chen
- Gynaecology and Obstetrics, The Second Affiliated Hospital of Harbin Medical University, Harbin Medical University, Heilongjiang 150081, PR China
| | - Xiaohong Qiu
- Gynaecology and Obstetrics, The Second Affiliated Hospital of Harbin Medical University, Harbin Medical University, Heilongjiang 150081, PR China.
| |
Collapse
|
4
|
Fatani F, Rauf S, Banerjee A, Shamim A. Breaking the Specificity Barrier in Microwave Sensing: Highly Specific Lactate Microwave Biosensor for Fitness and Exercise Optimization. ACS Sens 2025; 10:3658-3668. [PMID: 40181501 DOI: 10.1021/acssensors.5c00470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2025]
Abstract
Noninvasive biomarker sensing plays a vital role in health monitoring and sports physiology, particularly for tracking sweat lactate in real time to gauge exercise intensity without disrupting activity. This work introduces a high-specificity microwave biosensor for lactate detection, addressing the challenge of specificity seen in current microwave biosensors, which limits their practical applications. Our approach leverages a cost-effective complementary split-ring resonator (CSRR) combined with lactate oxidase (LOx) immobilized on spherical glass beads that act as mini-reactors within a microfluidic reservoir, enabling highly specific lactate sensing. The sensor was tested in phosphate buffer saline (PBS) and artificial sweat, achieving a high linear sensitivity of 10.9 and 11.3 MHz/mM, respectively, across lactate concentrations up to 150 mM and limit-of-detection (LOD) of 8.76 mM, with validation using the gold-standard HPLC method. It demonstrated excellent specificity against common interferences, including glucose, uric acid, and several ions. Testing with a diverse group of adult volunteers confirmed the sensor's capability to detect dynamic lactate changes during exercise and reliably identify the lactate threshold (LT), underscoring its promise for applications in sports physiology. This innovative method not only offers a powerful tool for lactate monitoring but also paves the way for enzyme-specific microwave biosensors adaptable to detect a range of biomarkers by simply exchanging the target enzyme.
Collapse
Affiliation(s)
- Firas Fatani
- Electrical and Computer Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Sakandar Rauf
- Electrical and Computer Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Apala Banerjee
- Electrical and Computer Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| | - Atif Shamim
- Electrical and Computer Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Kingdom of Saudi Arabia
| |
Collapse
|
5
|
Asadian E, Hekmat F, Hafezi Kahnamouei M, Mohammadpour R, Shahrokhian S, Sasanpour P. Supercapacitor-powered wearable biosensor for continuous lactate monitoring from sweat. Biosens Bioelectron 2025; 275:117226. [PMID: 39933404 DOI: 10.1016/j.bios.2025.117226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2024] [Revised: 01/29/2025] [Accepted: 02/02/2025] [Indexed: 02/13/2025]
Abstract
The development of wearable sensing platforms for continuous monitoring of sweat biomarkers has gained significant attention, particularly for lactate detection. This study presents the design and fabrication of a novel wearable lactate biosensor that integrates a flexible supercapacitor power supply with an advanced lactate sensing platform. The sensing platform features NiCo nanosheets electrodeposited onto nanocages of bimetallic CoFe Prussian Blue analogue (PBA), providing an optimal microenvironment for the immobilization of lactate oxidase (LOx) enzymes. The CoFe PBA nanocages act as efficient electrocatalysts for the reduction of hydrogen peroxide, enhancing the sensor's performance. The electrode exhibits a sensitivity of 262 μA mM-1cm-2 and demonstrates a short response time (<5 s), making it suitable for real-time monitoring applications. Additionally, the energy supply unit is constructed using a wearable conductive carbon textile (CCT) substrate modified with NiCoS through electrochemical deposition, achieving the necessary electrical conductivity. A flexible asymmetric supercapacitor (ASC) is then developed utilizing NiCoS@CCT and FeS@CNT@CCT as the positive and negative electrodes, respectively. This ASC exhibits remarkable electrochemical properties, including a high specific capacitance of 205 F g⁻1, notable energy density at elevated power densities, and excellent rate capability. Integrating these components with a custom-designed electronic circuit board results in a lightweight wearable sensor capable of continuous lactate monitoring in perspiration. This innovative approach demonstrates significant potential for advancing point-of-care health monitoring technologies.
Collapse
Affiliation(s)
- Elham Asadian
- Medical Nanotechnology and Tissue Engineering Research Center, Shahid Beheshti University of Medical Sciences, Tehran, 19689-17313, Iran; Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine, Shahid Beheshti University of Medical Sciences, Tehran, 19689-17313, Iran.
| | - Farzaneh Hekmat
- Department of Chemistry, Shahid Beheshti University, Tehran, 1983969411, Iran.
| | - Mohammad Hafezi Kahnamouei
- Department of Conservation of Cultural-Historical Properties and Archaeometry, Art University of Isfahan, P. O. Box: 1744, Isfahan, Iran
| | - Raheleh Mohammadpour
- Center for Nanoscience and Nanotechnology, Institute for Convergence Science & Technology, Sharif University of Technology, Tehran, Iran
| | - Saeed Shahrokhian
- Department of Chemistry, Sharif University of Technology, Azadi Avenue, Tehran, 11155-9516, Iran
| | - Pezhman Sasanpour
- Department of Medical Physics & Biomedical Engineering, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran; School of Nanoscience, Institute for Research in Fundamental Sciences (IPM), 19395-5531, Tehran, Iran.
| |
Collapse
|
6
|
Ma CB, Shang X, Sun M, Bo X, Bai J, Du Y, Zhou M. Emerging Multifunctional Wearable Sensors: Integrating Multimodal Sweat Analysis and Advanced Material Technologies for Next-Generation Health Monitoring. ACS Sens 2025; 10:2388-2408. [PMID: 40162570 DOI: 10.1021/acssensors.4c03396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2025]
Abstract
Sweat, a noninvasive and readily accessible biofluid, offers significant potential in health monitoring through its diverse biomarker profile, including electrolytes, metabolites, and hormones, which reflect physiological states in real time. Multimodal wearable sensors, integrating chemical, physical, and thermal sensing capabilities, have emerged as transformative tools for capturing these biomarkers alongside additional physiological signals. By combining advanced materials such as hydrogels, MXenes, and graphene with innovative structural designs, these sensors enable simultaneous monitoring of biomarkers (e.g., glucose, sodium, and cortisol) alongside parameters like movement and temperature. This Review systematically explores the classification and design of multimodal sensors, emphasizing their ability to address health monitoring challenges across applications including metabolic health management, stress detection, and hydration assessment. Key innovations in functional materials, such as conductive hydrogels and biomimetic structures, are discussed alongside challenges in signal integration, data processing, and power management. Additionally, advancements in self-powered systems and energy harvesting technologies have been highlighted as critical enablers for continuous, real-time monitoring. The Review concludes with a perspective on future directions, emphasizing the need for scalable manufacturing techniques, artificial intelligence integration, and standardized frameworks to enhance sensor functionality and adoption. Multimodal wearable sensors, by seamlessly integrating health data into daily life, hold the promise of transforming personalized healthcare, enabling proactive management of health and wellness through noninvasive, comprehensive, and real-time monitoring.
Collapse
Affiliation(s)
- Chong-Bo Ma
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin 130024, China
| | - Xudong Shang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
- School of Chemistry and Life Science, Advanced Institute of Materials Science, Changchun University of Technology, Changchun, Jilin 130012, China
| | - Mimi Sun
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin 130024, China
| | - Xiangjie Bo
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin 130024, China
| | - Jing Bai
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin 130024, China
| | - Yan Du
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China
| | - Ming Zhou
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin 130024, China
| |
Collapse
|
7
|
Fu Y, Kang S, Zhou G, Huang X, Tan L, Gao C, Dai S, Lin C. Unlocking body-surface physiological evolution via IR-temperature dual sensing with single chalcogenide fiber. LIGHT, SCIENCE & APPLICATIONS 2025; 14:173. [PMID: 40280924 PMCID: PMC12032074 DOI: 10.1038/s41377-025-01840-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Revised: 03/13/2025] [Accepted: 03/19/2025] [Indexed: 04/29/2025]
Abstract
Improvements to body-surface physiological monitoring ability including real-time, accuracy and integration, are essential to meet the expansive demands for personal healthcare. As part of this, simultaneous monitoring of sweat metabolites and body temperature offers an exciting path to maximizing diagnostic precision and minimizing morbidity rates. Herein, we report a high-performance biomarker-temperature sensor made of a single As3Se5Te2 chalcogenide glass fiber to monitor physiology evolution on body-surface. The sensor integrates efficient thermal resistance and fiber evanescent wave effects, permitting the independent sensing of temperature and biomarkers with an ultrahigh temperature coefficient of resistance (-5.84% K-1), rapid temperature response (0.3 s) and excellent IR sensing sensitivity. Moreover, by attaching a fiber to the wrist, we demonstrate simultaneous observation of both sweat metabolite (urea and lactate) and temperature changes during exercise. This illuminating sensing method will provide crucial capabilities in physiological monitoring and pave the way for advanced personalized diagnostic.
Collapse
Affiliation(s)
- Yanqing Fu
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Shiliang Kang
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China.
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China.
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China.
| | - Gangjie Zhou
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Xinxiang Huang
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Linling Tan
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Chengwei Gao
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Shixun Dai
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China
| | - Changgui Lin
- Laboratory of Infrared Materials and Devices, The Research Institute of Advanced Technologies, Ningbo University, Ningbo, 315211, China.
- Zhejiang Key Laboratory of Advanced Optical Functional Materials and Devices, Ningbo, 315211, China.
- Engineering Research Center for Advanced Infrared Photoelectric Materials and Devices of Zhejiang Province, Ningbo, 315211, China.
| |
Collapse
|
8
|
Wei Q, Rojas D, Wang Q, Zapata-Pérez R, Xuan X, Molinero-Fernández Á, Crespo GA, Cuartero M. Wearable 3D-Printed Microneedle Sensor for Intradermal Temperature Monitoring. ACS Sens 2025. [PMID: 40230020 DOI: 10.1021/acssensors.4c03681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/16/2025]
Abstract
Accurate temperature monitoring plays a crucial role in understanding the physiological status of patients and the early diagnosis of diseases commonly associated with local and global infections. Intradermal temperature measurement is, in principle, more precise than skin surface detection, as it prevents interference from environmental temperature changes and skin secretions. However, to date, precise and reliable intradermal temperature monitoring in a real-time and continuous manner remains a challenge. We propose herein high-resolution 3D printing to fabricate a mechanically robust and biocompatible hollow microneedle, filled with a temperature-responsive conducting polymer (poly(3,4-ethylenedioxythiophene): polystyrenesulfonate, PEDOT:PSS) to develop a microneedle temperature sensor (T-MN). The significance is 2-fold: rational design of robust MNs with high resolution in the micrometer domain and the implementation of a conducting polymer in a MN format for temperature sensing. The analytical performance of the developed T-MN is in vitro evaluated under mimicked intradermal conditions, demonstrating good sensitivity (-0.74%° C-1), resolution (0.2 °C), repeatability (RSD = 2%), reproducibility (RSD = 2%), reversibility, and medium-term stability. On-body temperature monitoring is performed on six euthanized rats for 80 min. The results presented good agreement with those obtained using a commercial optical temperature probe, which was intradermally inserted into the rat skin. The reliability of utilizing the T-MN for precise and continuous intradermal temperature monitoring was successfully demonstrated, noting its potential use for patient monitoring in the near future but also temperature compensation for MN (bio)sensors that may need it.
Collapse
Affiliation(s)
- Qikun Wei
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, Stockholm SE-114 28, Sweden
| | - Daniel Rojas
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, Murcia 30107, Spain
| | - Qianyu Wang
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, Stockholm SE-114 28, Sweden
| | - Ruben Zapata-Pérez
- Group of Metabolism and Genetic Regulation of Disease, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, Murcia 30107, Spain
| | - Xing Xuan
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, Murcia 30107, Spain
| | - Águeda Molinero-Fernández
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, Murcia 30107, Spain
| | - Gastón A Crespo
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, Stockholm SE-114 28, Sweden
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, Murcia 30107, Spain
| | - María Cuartero
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, Stockholm SE-114 28, Sweden
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, Murcia 30107, Spain
| |
Collapse
|
9
|
Decorte R, Vanhaeverbeke J, VanDen Berghe S, Slembrouck M, Verstockt S. Continuous Monitoring of Recruits During Military Basic Training to Mitigate Attrition. SENSORS (BASEL, SWITZERLAND) 2025; 25:1828. [PMID: 40292971 PMCID: PMC11945558 DOI: 10.3390/s25061828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2025] [Revised: 03/12/2025] [Accepted: 03/13/2025] [Indexed: 04/30/2025]
Abstract
This paper explores the use of wearable technology (Garmin Fenix 7) to monitor physiological and psychological factors contributing to attrition during basic military training. Attrition, or the voluntary departure of recruits from the military, often results from physical and psychological challenges, such as fatigue, injury, and stress, which lead to significant costs for the military. To better understand and mitigate attrition, we designed and implemented a comprehensive and continuous data-capturing methodology to monitor 63 recruits during their basic infantry training. It's optimized for military use by being minimally invasive (for both recruits and operators), preventing data leakage, and being built for scale. We analysed data collected from two test phases, focusing on seven key psychometric and physical features derived from baseline questionnaires and physiological measurements from wearable devices. The preliminary results revealed that recruits at risk of attrition tend to cluster in specific areas of the feature space in both Linear Discriminant Analysis (LDA) and Principal Component Analysis (PCA). Key indicators of attrition included low motivation, low resilience, and a stress mindset. Furthermore, we developed a predictive model using physiological data, such as sleep scores and step counts from Garmin devices, achieving a macro mean absolute error (MAE) of 0.74. This model suggests the potential to reduce the burden of daily wellness questionnaires by relying on continuous, unobtrusive monitoring.
Collapse
Affiliation(s)
- Robbe Decorte
- IDLab, Ghent University-Imec, Technologiepark-Zwijnaarde 122, 9052 Ghent, Belgium (S.V.)
| | - Jelle Vanhaeverbeke
- IDLab, Ghent University-Imec, Technologiepark-Zwijnaarde 122, 9052 Ghent, Belgium (S.V.)
| | - Sarah VanDen Berghe
- Department of Rehabilitation Sciences, Ghent University, C. Heymanslaan 10, 9000 Ghent, Belgium
| | - Maarten Slembrouck
- IDLab, Ghent University-Imec, Technologiepark-Zwijnaarde 122, 9052 Ghent, Belgium (S.V.)
| | - Steven Verstockt
- IDLab, Ghent University-Imec, Technologiepark-Zwijnaarde 122, 9052 Ghent, Belgium (S.V.)
| |
Collapse
|
10
|
Ji J, Xiao J, Zhang F, Wang Z, Zhou T, Niu X, Zhang W, Sang S, Chai X, Yan S. A wearable enzyme sensor enabled by the floating-gate OECT with poly(benzimidazobenzophenanthroline) as the catalytic layer. J Nanobiotechnology 2025; 23:120. [PMID: 39972358 PMCID: PMC11837302 DOI: 10.1186/s12951-025-03189-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Accepted: 02/01/2025] [Indexed: 02/21/2025] Open
Abstract
With the advantages of miniaturization, simple device structure, and fast response, the organic electrochemical transistor (OECT) has become an emerging platform for developing wearable enzyme sensors for real-time health monitoring. The floating gate (FG) OECT employs a distinct signal acquisition and amplification structure, mitigating the effects of non-specific physical adsorption during the sensing process and preventing contamination of the electrolyte solution by side reaction products. The current work reports a feasible wearable enzyme sensor using a poly(benzimidazobenzophenanthroline) (BBL)-Nafion-enzyme-Nafion stacking structure as the sensing layer of the FG OECT. Based on the experimental results, the BBL film with an area of 3.14 mm2 and a thickness of 175 nm can generate an open circuit potential of 199.61 mV in 10- 1 M hydrogen peroxide compared with the blank control. Then, the FG OECT is integrated with the flexible microfluidic systems for on-skin detection of glucose, lactate, and uric acid with sensitivities of 92.47, 152.15, and 74.27 µA·dec- 1, respectively. This FG OECT-based wearable enzyme sensor will open new windows for multiplexed detection of sweat metabolites.
Collapse
Affiliation(s)
- Jianlong Ji
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
| | - Jing Xiao
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
| | - Fan Zhang
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
| | - Zhaoqun Wang
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
| | - Tianyuan Zhou
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
- 6D Artificial Intelligence Biomedical Research Institute, Taiyuan, China
| | - Xiaorong Niu
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
- 6D Artificial Intelligence Biomedical Research Institute, Taiyuan, China
| | - Wendong Zhang
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China
| | - Shengbo Sang
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China.
| | - Xiaojie Chai
- College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China.
| | - Sheng Yan
- Institute for Advanced Study Shenzhen University, Shenzhen, China.
| |
Collapse
|
11
|
Wang Y, Wu X, Liu Y, Zhang J, Wang L, Luo X. A wearable platform for biochemical sweat analysis using photonic crystal hydrogel. Anal Chim Acta 2025; 1338:343590. [PMID: 39832860 DOI: 10.1016/j.aca.2024.343590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2024] [Revised: 12/13/2024] [Accepted: 12/24/2024] [Indexed: 01/22/2025]
Abstract
Wearable systems for health monitoring are highly desired in personal diagnostics and precision medicine while challenges remain in constructing such wearable systems with reliability and high performance. Herein, we report a wearable platform for non-invasive monitoring biomarkers in sweat. The device is composed of a butterfly-shaped like microfluidic platform in which responsive photonic crystal hydrogels are embedded in each butterfly wing as sensors. Sweat lactate concentration and pH can be obtained via the color variation of the sensor with naked eyes. Accurate quantitative analysis of the two target analytes can be obtained via the image analysis on a mobile phone by integrating the linear range response to analytes within the physiological range. Moreover, the sensor exhibits good reproducibility, excellent selectivity and long-term stability. On-body trials have been conducted by attaching the device on volunteers' body, and the obtained results are consistent with those analyzed through standardized methods, demonstrating its potentiality in real-time and continuous monitoring sweat biomarkers. This non-invasive wearable sensor provides a new strategy for personal health monitoring and sports performance assessment.
Collapse
Affiliation(s)
- Yingli Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Xiao Wu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Yun Liu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Jincheng Zhang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China
| | - Lei Wang
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| | - Xiliang Luo
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
| |
Collapse
|
12
|
Boček Ž, Zubak M, Kassal P. Fully Inkjet-Printed Flexible Graphene-Prussian Blue Platform for Electrochemical Biosensing. BIOSENSORS 2025; 15:28. [PMID: 39852079 PMCID: PMC11763782 DOI: 10.3390/bios15010028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2024] [Revised: 12/24/2024] [Accepted: 12/30/2024] [Indexed: 01/26/2025]
Abstract
Prussian Blue (PB) is commonly incorporated into screen-printed enzymatic devices since it enables the determination of the enzymatically produced hydrogen peroxide at low potentials. Inkjet printing is gaining popularity in the development of electrochemical sensors as a substitute for screen printing. This work presents a fully inkjet-printed graphene-Prussian Blue platform, which can be paired with oxidase enzymes to prepare a biosensor of choice. The graphene electrode was inkjet-printed on a flexible polyimide substrate and then thermally and photonically treated with intense pulsed light, followed by inkjet printing of a PB nanoparticle suspension. The optimization of post-printing treatment and electrode deposition conditions was performed to yield a platform with minimal sheet resistance and peak potential differences. A thorough study of PB deposition was conducted: the fully inkjet-printed system was compared against sensors with PB deposited chemically or by drop casting the PB suspension on different kinds of carbon electrodes (glassy carbon, commercial screen-printed, and in-house inkjet-printed electrodes). For hydrogen peroxide detection, the fully inkjet-printed platform exhibits excellent sensitivity, a wider linear range, better linearity, and greater stability towards higher concentrations of peroxide than the other tested electrodes. Finally, lactate oxidase was immobilized in a chitosan matrix, and the prepared biosensor exhibited analytical performance comparable to other lactate sensors found in the literature in a wide, physiologically relevant linear range for measuring lactate concentration in sweat. The development of mediator-modified electrodes with a single fabrication technology, as demonstrated here, paves the way for the scalable production of low-cost, wearable, and flexible biosensors.
Collapse
Affiliation(s)
| | | | - Petar Kassal
- University of Zagreb, Faculty of Chemical Engineering & Technology, Trg Marka Marulića 19, 10000 Zagreb, Croatia; (Ž.B.); (M.Z.)
| |
Collapse
|
13
|
Dykstra G, Chapa I, Liu Y. Reagent-Free Lactate Detection Using Prussian Blue and Electropolymerized-Molecularly Imprinted Polymers-Based Electrochemical Biosensors. ACS APPLIED MATERIALS & INTERFACES 2024; 16:66921-66931. [PMID: 38691422 DOI: 10.1021/acsami.3c19448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2024]
Abstract
Sweat lactate, a promising biomarker for assessing physical performance and health conditions, calls for noninvasive, convenient, and affordable detection methods. This study leverages molecularly imprinted polymers (MIPs) as a synthetic biorecognition element for lactate detection due to their affordability and high stability. Traditional MIPs-based electrochemical sensors often require external redox probes such as ferricyanide/ferrocyanide in the solution to signal the binding between analytes and MIPs, which restricts their applicability. To address this, our study introduces an innovative approach utilizing a layer of Prussian blue (PB) nanoparticles as the internal redox probe on screen-printed carbon electrodes (SPCE), followed by a layer of electropolymerized MIP (eMIP) for molecular recognition, enabling reagent-free lactate detection. The real-time growth of eMIP and the processes of template elution and lactate rebinding were examined and validated using electrochemical surface plasmon resonance (EC-SPR) spectroscopy. The sensor's performance was thoroughly investigated using Differential Pulsed Voltammetry (DPV) and Electrochemical Impedance Spectroscopy (EIS) with samples spiked in 0.1 M KCl solution and artificial sweat. The developed sensors demonstrated a fast and selective response to lactate, detecting concentrations from 1 to 35 mM with a Limit of Detection (LOD) of 0.20 mM, defined by a signal-to-noise ratio of 3 in the DPV measurements. They also exhibited excellent reproducibility, reusability, and a shelf life of up to 10 months under ambient conditions. These eMIP/PB/SPCE-based lactate sensors show considerable potential as point-of-care (POC) devices for sweat lactate detection, and the technology could be adapted for reagent-free detection of a broad spectrum of molecules.
Collapse
Affiliation(s)
- Grace Dykstra
- Department of Chemical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, Michigan 49931, United States
| | - Isabel Chapa
- Department of Chemical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, Michigan 49931, United States
| | - Yixin Liu
- Department of Chemical Engineering, Michigan Technological University, 1400 Townsend Drive, Houghton, Michigan 49931, United States
| |
Collapse
|
14
|
Kim MS, Almuslem AS, Babatain W, Bahabry RR, Das UK, El-Atab N, Ghoneim M, Hussain AM, Kutbee AT, Nassar J, Qaiser N, Rojas JP, Shaikh SF, Torres Sevilla GA, Hussain MM. Beyond Flexible: Unveiling the Next Era of Flexible Electronic Systems. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2406424. [PMID: 39390819 DOI: 10.1002/adma.202406424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 07/31/2024] [Indexed: 10/12/2024]
Abstract
Flexible electronics are integral in numerous domains such as wearables, healthcare, physiological monitoring, human-machine interface, and environmental sensing, owing to their inherent flexibility, stretchability, lightweight construction, and low profile. These systems seamlessly conform to curvilinear surfaces, including skin, organs, plants, robots, and marine species, facilitating optimal contact. This capability enables flexible electronic systems to enhance or even supplant the utilization of cumbersome instrumentation across a broad range of monitoring and actuation tasks. Consequently, significant progress has been realized in the development of flexible electronic systems. This study begins by examining the key components of standalone flexible electronic systems-sensors, front-end circuitry, data management, power management and actuators. The next section explores different integration strategies for flexible electronic systems as well as their recent advancements. Flexible hybrid electronics, which is currently the most widely used strategy, is first reviewed to assess their characteristics and applications. Subsequently, transformational electronics, which achieves compact and high-density system integration by leveraging heterogeneous integration of bare-die components, is highlighted as the next era of flexible electronic systems. Finally, the study concludes by suggesting future research directions and outlining critical considerations and challenges for developing and miniaturizing fully integrated standalone flexible electronic systems.
Collapse
Affiliation(s)
- Min Sung Kim
- mmh Labs (DREAM), Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA
| | - Amani S Almuslem
- Department of Physics, College of Science, King Faisal University, Prince Faisal bin Fahd bin Abdulaziz Street, Al-Ahsa, 31982, Saudi Arabia
| | - Wedyan Babatain
- Media Lab, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
| | - Rabab R Bahabry
- Department of Physical Sciences, College of Science, University of Jeddah, Jeddah, 21589, Saudi Arabia
| | - Uttam K Das
- Department of Electrical and Computer Engineering, Computer Electrical Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia
| | - Nazek El-Atab
- Department of Electrical and Computer Engineering, Computer Electrical Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia
| | - Mohamed Ghoneim
- Logic Technology Development Quality and Reliability, Intel Corporation, Hillsboro, OR, 97124, USA
| | - Aftab M Hussain
- International Institute of Information Technology (IIIT) Hyderabad, Gachibowli, Hyderabad, 500 032, India
| | - Arwa T Kutbee
- Department of Physics, College of Science, King AbdulAziz University, Jeddah, 21589, Saudi Arabia
| | - Joanna Nassar
- Department of Electrical and Computer Engineering, Computer Electrical Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia
| | - Nadeem Qaiser
- Department of Electrical and Computer Engineering, Computer Electrical Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia
| | - Jhonathan P Rojas
- Electrical Engineering Department & Interdisciplinary Research Center for Advanced Materials, King Fahd University of Petroleum and Minerals, Academic Belt Road, Dhahran, 31261, Saudi Arabia
| | | | - Galo A Torres Sevilla
- Department of Electrical and Computer Engineering, Computer Electrical Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia
| | - Muhammad M Hussain
- mmh Labs (DREAM), Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN, 47906, USA
| |
Collapse
|
15
|
Cheng C, Ganguly S, Li P, Tang X. Detecting Hypoxia Through the Non-Invasive and Simultaneous Monitoring of Sweat Lactate and Tissue Oxygenation. BIOSENSORS 2024; 14:584. [PMID: 39727849 DOI: 10.3390/bios14120584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2024] [Revised: 11/25/2024] [Accepted: 11/27/2024] [Indexed: 12/28/2024]
Abstract
Hypoxia, characterized by inadequate tissue oxygenation, may result in tissue damage and organ failure if not addressed. Current detection approaches frequently prove insufficient, depending on symptoms and rudimentary metrics such as tissue oxygenation, which fail to comprehensively identify the onset of hypoxia. The European Pressure Ulcer Advisory Panel (EPUAP) has recognized sweat lactate as a possible marker for the early identification of decubitus ulcers, nevertheless, neither sweat lactate nor oxygenation independently provides an appropriate diagnosis of hypoxia. We have fabricated a wearable device that non-invasively and concurrently monitors sweat lactate and tissue oxygenation to fill this gap. The apparatus comprises three essential components: (i) a hydrogel-based colorimetric lactate biosensor, (ii) a near-infrared (NIR) sensor for assessing tissue oxygenation, and (iii) an integrated form factor for enhanced wearability. The lactate sensor alters its hue upon interaction with lactate in sweat, whereas the NIR sensor monitors tissue oxygenation levels in real-time. The device underwent testing on phantom exhibiting tissue-mimicking characteristics and on human sweat post aerobic and anaerobic activities. Moreover, the device was demonstrated to be capable of real-time "on-body" simultaneous monitoring of sweat lactate spikes and tissue oxygenation (StO2) drops, which showed strong correlation during a hypoxia protocol. This innovative technology has a wide range of potential applications, such as post-operative care, sepsis detection, and athletic performance monitoring, and may provide economical healthcare solutions in resource-limited regions.
Collapse
Affiliation(s)
- Cindy Cheng
- Department of Chemistry, University of Waterloo, 200 University Ave West, Waterloo, ON N2L 3G1, Canada
| | - Sayan Ganguly
- Department of Chemistry, University of Waterloo, 200 University Ave West, Waterloo, ON N2L 3G1, Canada
| | - Pei Li
- Department of Chemistry, University of Waterloo, 200 University Ave West, Waterloo, ON N2L 3G1, Canada
| | - Xiaowu Tang
- Department of Chemistry, University of Waterloo, 200 University Ave West, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
16
|
Assalve G, Lunetti P, Di Cagno A, De Luca EW, Aldegheri S, Zara V, Ferramosca A. Advanced Wearable Devices for Monitoring Sweat Biochemical Markers in Athletic Performance: A Comprehensive Review. BIOSENSORS 2024; 14:574. [PMID: 39727839 DOI: 10.3390/bios14120574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 11/22/2024] [Accepted: 11/25/2024] [Indexed: 12/28/2024]
Abstract
Wearable technology has advanced significantly, offering real-time monitoring of athletes' physiological parameters and optimizing training and recovery strategies. Recent developments focus on biosensor devices capable of monitoring biochemical parameters in addition to physiological ones. These devices employ noninvasive methods such as sweat analysis, which reveals critical biomarkers like glucose, lactate, electrolytes, pH, and cortisol. These biomarkers provide valuable insights into an athlete's energy use, hydration status, muscle function, and stress levels. Current technologies utilize both electrochemical and colorimetric methods for sweat analysis, with electrochemical methods providing higher precision despite potential signal interference. Wearable devices such as epidermal patches, temporary tattoos, and fabric-based sensors are preferred for their flexibility and unobtrusive nature compared to more rigid conventional wearables. Such devices leverage advanced materials and transmit real-time data to computers, tablets, or smartphones. These data would aid coaches and sports medical personnel in monitoring athletes' health, optimizing diets, and developing training plans to enhance performance and reduce injuries.
Collapse
Affiliation(s)
- Graziana Assalve
- Department of Experimental Medicine, University of Salento, 73100 Lecce, Italy
| | - Paola Lunetti
- Department of Experimental Medicine, University of Salento, 73100 Lecce, Italy
| | - Alessandra Di Cagno
- Department of Human Sciences, Guglielmo Marconi University, 00193 Rome, Italy
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", 00135 Rome, Italy
| | - Ernesto William De Luca
- Department of Engineering Sciences, Guglielmo Marconi University, 00193 Rome, Italy
- Institute of Technical and Business Information Systems, Otto-von-Guericke-University of Magdeburg, 39106 Magdeburg, Germany
| | - Stefano Aldegheri
- Department of Engineering Sciences, Guglielmo Marconi University, 00193 Rome, Italy
| | - Vincenzo Zara
- Department of Experimental Medicine, University of Salento, 73100 Lecce, Italy
| | | |
Collapse
|
17
|
Xuan X, Rojas D, Lozano IMD, Cuartero M, Crespo GA. Demonstration of a Validated Direct Current Wearable Device for Monitoring Sweat Rate in Sports. SENSORS (BASEL, SWITZERLAND) 2024; 24:7243. [PMID: 39599020 PMCID: PMC11598451 DOI: 10.3390/s24227243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2024] [Revised: 10/30/2024] [Accepted: 11/11/2024] [Indexed: 11/29/2024]
Abstract
Sweat rate magnitude is a desired outcome for any wearable sensing patch dedicated to sweat analysis. Indeed, sweat rate values can be used two-fold: self-diagnosis of dehydration and correction/normalization of other physiological metrics, such as Borg scale, VO2, and different chemical species concentrations. Herein, a reliable sweat rate belt device for sweat rate monitoring was developed. The device measures sweat rates in the range from 1.0 to 5.0 µL min-1 (2 to 10 µL min-1 cm-2), which covers typical values for humans. The working mechanism is based on a new direct current (DC) step protocol activating a series of differential resistance measurements (spatially separated by 800 µm) that is gradually initiated by the action of sweat, which flows along a customized microfluidic track (~600 µm in width, 10 mm in length, and 235 µm in thickness). The device has a volumetric capacity of ~16 µL and an acquisition frequency between 0.010 and 0.043 Hz within the measured sweat rate range. Importantly, instead of using a typical and rather complex AC signal interrogation and acquisition, we put forward the DC approach, offering several benefits, such as simplified circuit design for easier fabrication and lower costs, as well as reduced power consumption and suitability for wearable applications. For the validation, either the commercial sweat collector (colorimetric) or the developed device was performed. In five on-body tests, an acceptable variation of ca. 10% was obtained. Overall, this study demonstrates the potential of the DC-based device for the monitoring of sweat rate and also its potential for implementation in any wearable sweat platform.
Collapse
Affiliation(s)
- Xing Xuan
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain; (X.X.); (D.R.); (I.M.D.L.); (M.C.)
| | - Daniel Rojas
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain; (X.X.); (D.R.); (I.M.D.L.); (M.C.)
| | - Isabel Maria Diaz Lozano
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain; (X.X.); (D.R.); (I.M.D.L.); (M.C.)
| | - Maria Cuartero
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain; (X.X.); (D.R.); (I.M.D.L.); (M.C.)
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| | - Gastón A. Crespo
- UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain; (X.X.); (D.R.); (I.M.D.L.); (M.C.)
- Department of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden
| |
Collapse
|
18
|
Salih IL, Alshatteri AH, Omer KM. Role of wearable electrochemical biosensors in monitoring renal function biomarkers in sweat: a review. ANAL SCI 2024; 40:1969-1986. [PMID: 39093545 DOI: 10.1007/s44211-024-00635-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 07/15/2024] [Indexed: 08/04/2024]
Abstract
Real-time detection of renal biomarkers is crucial for immediate and continuous monitoring of kidney function, facilitating early diagnosis and intervention in kidney-related disorders. This proactive approach enables timely adjustments in treatment plans, particularly in critical situations, and enhances overall patient care. Wearable devices emerge as a promising solution, enabling non-invasive and real-time data collection. This comprehensive review investigates numerous types of wearable sensors designed to detect kidney biomarkers in body fluids such as sweat. It critically evaluates the precision, dependability, and user-friendliness of these devices, contemplating their seamless integration into daily life for continuous health tracking. The review highlights the potential influence of wearable technology on individualized renal healthcare and its role in preventative medicine while also addressing challenges and future directions. The review's goal is to provide guidance to academics, healthcare professionals, and technologists working on wearable solutions for renal biomarker detection by compiling the body of current knowledge and advancements.
Collapse
Affiliation(s)
- Ibrahim Luqman Salih
- Department of Pharmacy, Raparin Technical and Vocational Institute, Rania, Sulaymaniyah, Kurdistan Region, 46012, Iraq
- Department of Chemistry, College of Science, University of Raparin, RaniaSulaymaniyah, Kurdistan Region, 46012, Iraq
| | - Azad H Alshatteri
- Department of Chemistry, University of Garmian, Darbandikhan Road, Kalar City, Sulaimaniyah, Kurdistan Region, Iraq.
| | - Khalid M Omer
- Department of Chemistry, College of Science, University of Sulaimani, Sulaymaniyah, Kurdistan Region, Iraq
| |
Collapse
|
19
|
Weng X, Li M, Chen L, Peng B, Jiang H. A wearable nanozyme-enzyme electrochemical biosensor for sweat lactate monitoring. Talanta 2024; 279:126675. [PMID: 39116726 DOI: 10.1016/j.talanta.2024.126675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 07/12/2024] [Accepted: 08/05/2024] [Indexed: 08/10/2024]
Abstract
In this study, we developed a wearable nanozyme-enzyme electrochemical biosensor that enablies sweat lactate monitoring. The biosensor comprises a flexible electrode system prepared on a polyimide (PI) film and the Janus textile for unidirectional sweat transport. We obtained favorable electrochemical activities for hydrogen peroxide reduction by modifying the laser-scribed graphene (LSG) electrode with cerium dioxide (CeO2)-molybdenum disulphide (MoS2) nanozyme and gold nanoparticles (AuNPs). By further immobilisation of lactate oxidase (LOx), the proposed biosensor achieves chronoamperometric lactate detection in artificial sweat within a range of 0.1-50.0 mM, a high sensitivity of 25.58 μA mM-1cm-2 and a limit of detection (LoD) down to 0.135 mM, which fully meets the requirements of clinical diagnostics. We demonstrated accurate lactate measurements in spiked artificial sweat, which is consistent with standard ELISA results. To monitor the sweat produced by volunteers while exercising, we conducted on-body tests, showcasing the wearable biosensor's ability to provide clinical sweat lactate diagnosis for medical treatment and sports management.
Collapse
Affiliation(s)
- Xuan Weng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China; Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong, 523808, China
| | - Ming Li
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China
| | - Longyan Chen
- Department of Biomedical, Industrial & Systems Engineering, Gannon University, 109 University Square, Erie, PA, 16541, USA
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu, Sichuan, 611731, China; Institute of Electronic and Information Engineering of UESTC in Guangdong, Dongguan, Guangdong, 523808, China.
| |
Collapse
|
20
|
Tan SCL, Ning Y, Yu Y, Goh WP, Jiang C, Liu L, Zheng XT, Yang L. Stretchable Sweat Lactate Sensor with Dual-Signal Read-Outs. Chem Asian J 2024; 19:e202400496. [PMID: 39037569 DOI: 10.1002/asia.202400496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/07/2024] [Accepted: 07/16/2024] [Indexed: 07/23/2024]
Abstract
Innovations in wearable sweat sensors hold great promise to provide deeper insights into molecular level health information non-invasively. Lactate, a key metabolite present in sweat, holds immense significance in assessing physiological conditions and performance in sports physiology and health sensing. This paper presents the development and characterization of stretchable electrodes with ultrahigh active surface area of 648 % for lactate sensing. The as-printed stretchable electrodes were functionalized with an electron transfer layer comprising Toluidine Blue O and multi-walled carbon nanotubes (MWCNTs), and an enzymatic layer consisting of lactate dehydrogenase with β-Nicotinamide adenine dinucleotide as the cofactor for lactate selectivity. This sensor achieves a dual-signal read-out in which both electrochemical and fluorescence signals were obtained during lactate detection, demonstrating promising sensor performance in terms of sensitivity and reliability. We demonstrate the robustness of the dual-signal sensor under simulated conditions of physical deformation and shifted excitation. Under these compromised conditions, the performance of the stretchable electrodes remained largely unaffected, showcasing their potential for robust and adaptable sensing platforms in wearable health monitoring applications.
Collapse
Affiliation(s)
- Sherwin Chong Li Tan
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
| | - Yuetong Ning
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
- Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Republic of Singapore
| | - Yong Yu
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
| | - Wei Peng Goh
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
| | - Changyun Jiang
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
| | - Liyuan Liu
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
- Department of Biological Science, National University of Singapore, 16 Science Drive 4, Singapore, 117558, Republic of Singapore
| | - Xin Ting Zheng
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
| | - Le Yang
- Institute of Materials Research and Engineering (IMRE), Agency for Science, Technology and Research (A*STAR), 2 Fusionopolis Way, Innovis #08-03, Singapore, 138634, Republic of Singapore
- Department of Materials Science and Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore, 117575, Republic of Singapore
| |
Collapse
|
21
|
Marchianò V, Tricase A, Macchia E, Bollella P, Torsi L. Self-powered wearable biosensor based on stencil-printed carbon nanotube electrodes for ethanol detection in sweat. Anal Bioanal Chem 2024; 416:5303-5316. [PMID: 39134727 PMCID: PMC11416403 DOI: 10.1007/s00216-024-05467-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Revised: 07/24/2024] [Accepted: 07/26/2024] [Indexed: 09/22/2024]
Abstract
Herein we introduce a novel water-based graphite ink modified with multiwalled carbon nanotubes, designed for the development of the first wearable self-powered biosensor enabling alcohol abuse detection through sweat analysis. The stencil-printed graphite (SPG) electrodes, printed onto a flexible substrate, were modified by casting multiwalled carbon nanotubes (MWCNTs), electrodepositing polymethylene blue (pMB) at the anode to serve as a catalyst for nicotinamide adenine dinucleotide (NADH) oxidation, and hemin at the cathode as a selective catalyst for H2O2 reduction. Notably, alcohol dehydrogenase (ADH) was additionally physisorbed onto the anodic electrode, and alcohol oxidase (AOx) onto the cathodic electrode. The self-powered biosensor was assembled using the ADH/pMB-MWCNTs/SPG||AOx/Hemin-MWCNTs/SPG configuration, enabling the detection of ethanol as an analytical target, both at the anodic and cathodic electrodes. Its performance was assessed by measuring polarization curves with gradually increasing ethanol concentrations ranging from 0 to 50 mM. The biosensor demonstrated a linear detection range from 0.01 to 0.3 mM, with a detection limit (LOD) of 3 ± 1 µM and a sensitivity of 64 ± 2 μW mM-1, with a correlation coefficient of 0.98 (RSD 8.1%, n = 10 electrode pairs). It exhibited robust operational stability (over 2800 s with continuous ethanol turnover) and excellent storage stability (approximately 93% of initial signal retained after 90 days). Finally, the biosensor array was integrated into a wristband and successfully evaluated for continuous alcohol abuse monitoring. This proposed system displays promising attributes for use as a flexible and wearable biosensor employing biocompatible water-based inks, offering potential applications in forensic contexts.
Collapse
Affiliation(s)
- Verdiana Marchianò
- Department of Pharmacy-Pharmaceutical Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
- Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
| | - Angelo Tricase
- Department of Pharmacy-Pharmaceutical Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
- Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
| | - Eleonora Macchia
- Department of Pharmacy-Pharmaceutical Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
- Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
- Faculty of Science and Engineering, Åbo Akademi University, 20500, Turku, Finland
| | - Paolo Bollella
- Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy.
- Department of Chemistry, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy.
| | - Luisa Torsi
- Centre for Colloid and Surface Science, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
- Department of Chemistry, University of Bari Aldo Moro, Via E. Orabona, 4, 70125, Bari, Italy
| |
Collapse
|
22
|
Cho S, Shaban SM, Song R, Zhang H, Yang D, Kim MJ, Xiong Y, Li X, Madsen K, Wapnick S, Zhang S, Chen Z, Kim J, Guinto G, Li M, Lee M, Nuxoll RF, Shajari S, Wang J, Son S, Shin J, Aranyosi AJ, Wright DE, Kim TI, Ghaffari R, Huang Y, Kim DH, Rogers JA. A skin-interfaced microfluidic platform supports dynamic sweat biochemical analysis during human exercise. Sci Transl Med 2024; 16:eado5366. [PMID: 39231240 DOI: 10.1126/scitranslmed.ado5366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 06/14/2024] [Accepted: 08/15/2024] [Indexed: 09/06/2024]
Abstract
Blood lactate concentration is an established circulating biomarker for measuring muscle acidity and can be evaluated for monitoring endurance, training routines, or athletic performance. Sweat is an alternative biofluid that may serve similar purposes and offers the advantage of noninvasive collection and continuous monitoring. The relationship between blood lactate and dynamic sweat biochemistry for wearable engineering applications in physiological fitness remains poorly defined. Here, we developed a microfluidic wearable band with an integrated colorimetric timer and biochemical assays that temporally captures sweat and measures pH and lactate concentration. A colorimetric silver nanoplasmonic assay was used to measure the concentration of lactate, and dye-conjugated SiO2 nanoparticle-agarose composite materials supported dynamic pH analysis. We evaluated these sweat biomarkers in relation to blood lactate in human participant studies during cycling exercise of varying intensity. Iontophoresis-generated sweat pH from regions of actively working muscles decreased with increasing heart rate during exercise and was negatively correlated with blood lactate concentration. In contrast, sweat pH from nonworking muscles did not correlate with blood lactate concentration. Changes in sweat pH and blood lactate were observed in participants who did not regularly exercise but not in individuals who regularly exercised, suggesting a relationship to physical fitness and supporting further development for noninvasive, biochemical fitness evaluations.
Collapse
Affiliation(s)
- Soongwon Cho
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Samy M Shaban
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Petrochemical Department, Egyptian Petroleum Research Institute, Cairo, 11727, Egypt
| | - Ruihao Song
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Department of Chemical and Biological Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Haohui Zhang
- Departments of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Dasom Yang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Precision Biology Research Center (PBRC), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Min-Jae Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Yirui Xiong
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Xiuyuan Li
- Departments of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Kenneth Madsen
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Sarena Wapnick
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Shifan Zhang
- Department of Statistics, School of Computer, Data and Information Sciences, University of Wisconsin-Madison, Madison, WI 53706, USA
| | - Ziyu Chen
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Jiwon Kim
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Gianna Guinto
- College of Science and Health, DePaul University, Chicago, IL 60614, USA
| | - Michelle Li
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Minkyu Lee
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Shirley Ryan AbilityLab, Chicago, IL 60611, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL 60611, USA
| | - Ravi F Nuxoll
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Physics and Astronomy, Northwestern University, Evanston, IL 60208, USA
| | - Shaghayegh Shajari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
| | - Jin Wang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Pritzker School of Molecular Engineering, University of Chicago, Chicago, IL 60637, USA
| | - Seongeun Son
- Department of Bionano Engineering, Center for Bionano Intelligence Education and Research, Hanyang University, Ansan, 15588, Republic of Korea
| | - Jihoon Shin
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Alexander J Aranyosi
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Epicore Biosystems, Cambridge, MA 02139, USA
| | | | - Tae-Il Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Epicore Biosystems, Cambridge, MA 02139, USA
| | - Yonggang Huang
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208, USA
| | - Dong-Hwan Kim
- School of Chemical Engineering, Sungkyunkwan University, Suwon, 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208, USA
- Departments of Material Science and Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA
- Department of Neurological Surgery, Northwestern University, Evanston, IL 60208, USA
| |
Collapse
|
23
|
Haghayegh F, Norouziazad A, Haghani E, Feygin AA, Rahimi RH, Ghavamabadi HA, Sadighbayan D, Madhoun F, Papagelis M, Felfeli T, Salahandish R. Revolutionary Point-of-Care Wearable Diagnostics for Early Disease Detection and Biomarker Discovery through Intelligent Technologies. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2400595. [PMID: 38958517 PMCID: PMC11423253 DOI: 10.1002/advs.202400595] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 06/19/2024] [Indexed: 07/04/2024]
Abstract
Early-stage disease detection, particularly in Point-Of-Care (POC) wearable formats, assumes pivotal role in advancing healthcare services and precision-medicine. Public benefits of early detection extend beyond cost-effectively promoting healthcare outcomes, to also include reducing the risk of comorbid diseases. Technological advancements enabling POC biomarker recognition empower discovery of new markers for various health conditions. Integration of POC wearables for biomarker detection with intelligent frameworks represents ground-breaking innovations enabling automation of operations, conducting advanced large-scale data analysis, generating predictive models, and facilitating remote and guided clinical decision-making. These advancements substantially alleviate socioeconomic burdens, creating a paradigm shift in diagnostics, and revolutionizing medical assessments and technology development. This review explores critical topics and recent progress in development of 1) POC systems and wearable solutions for early disease detection and physiological monitoring, as well as 2) discussing current trends in adoption of smart technologies within clinical settings and in developing biological assays, and ultimately 3) exploring utilities of POC systems and smart platforms for biomarker discovery. Additionally, the review explores technology translation from research labs to broader applications. It also addresses associated risks, biases, and challenges of widespread Artificial Intelligence (AI) integration in diagnostics systems, while systematically outlining potential prospects, current challenges, and opportunities.
Collapse
Affiliation(s)
- Fatemeh Haghayegh
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Alireza Norouziazad
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Elnaz Haghani
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Ariel Avraham Feygin
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Reza Hamed Rahimi
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Hamidreza Akbari Ghavamabadi
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Deniz Sadighbayan
- Department of BiologyFaculty of ScienceYork UniversityTorontoONM3J 1P3Canada
| | - Faress Madhoun
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Manos Papagelis
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| | - Tina Felfeli
- Department of Ophthalmology and Vision SciencesUniversity of TorontoOntarioM5T 3A9Canada
- Institute of Health PolicyManagement and EvaluationUniversity of TorontoOntarioM5T 3M6Canada
| | - Razieh Salahandish
- Laboratory of Advanced Biotechnologies for Health Assessments (Lab‐HA)Biomedical Engineering ProgramLassonde School of EngineeringYork UniversityTorontoM3J 1P3Canada
- Department of Electrical Engineering and Computer Science (EECS)Lassonde School of EngineeringYork UniversityTorontoONM3J 1P3Canada
| |
Collapse
|
24
|
García-Guzmán JJ, Jiménez Heras JM, López-Iglesias D, González-Álvarez RJ, Cubillana-Aguilera L, González Macías C, Fernández Alba JJ, Palacios-Santander JM. New spin coated multilayer lactate biosensor for acidosis monitoring in continuous flow assisted with an electrochemical pH probe. Mikrochim Acta 2024; 191:526. [PMID: 39120744 PMCID: PMC11315777 DOI: 10.1007/s00604-024-06602-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Accepted: 08/01/2024] [Indexed: 08/10/2024]
Abstract
A LOx-based electrochemical biosensor for high-level lactate determination was developed. For the construction of the biosensor, chitosan and Nafion layers were integrated by using a spin coating procedure, leading to less porous surfaces in comparison with those recorded after a drop casting procedure. The analytical performance of the resulting biosensor for lactate determination was evaluated in batch and flow regime, displaying satisfactory results in both modes ranging from 0.5 to 20 mM concentration range for assessing the lactic acidosis. Finally, the lactate levels in raw serum samples were estimated using the biosensor developed and verified with a blood gas analyzer. Based on these results, the biosensor developed is promising for its use in healthcare environment, after its proper miniaturization. A pH probe based on common polyaniline-based electrochemical sensor was also developed to assist the biosensor for the lactic acidosis monitoring, leading to excellent results in stock solutions ranging from 6.0 to 8.0 mM and raw plasma samples. The results were confirmed by using two different approaches, blood gas analyzer and pH-meter. Consequently, the lactic acidosis monitoring could be achieved in continuous flow regime using both (bio)sensors.
Collapse
Affiliation(s)
- Juan José García-Guzmán
- Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain
| | - José Manuel Jiménez Heras
- Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain
| | - David López-Iglesias
- Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain
| | - Rafael Jesús González-Álvarez
- Instituto de Investigación e Innovación Biomédica de Cádiz (INiBICA), Hospital Universitario 'Puerta del Mar', Universidad de Cádiz, 11009, Cádiz, Spain
| | - Laura Cubillana-Aguilera
- Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), Universidad de Cádiz, República Saharaui, S/N. 11510, Puerto Real, Cádiz, Spain.
| | - Carmen González Macías
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Puerto Real, 11510, Puerto Real, Cádiz, Spain
| | - Juan Jesús Fernández Alba
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Puerto Real, 11510, Puerto Real, Cádiz, Spain.
| | - José María Palacios-Santander
- Institute of Research on Electron Microscopy and Materials (IMEYMAT), Department of Analytical Chemistry, Faculty of Sciences, Campus de Excelencia Internacional del Mar (CEIMAR), Universidad de Cádiz, República Saharaui, S/N. 11510, Puerto Real, Cádiz, Spain
| |
Collapse
|
25
|
He Q, Wang C, Jain R, Byrnes J, Farquhar ER, Reed E, Berezovsky E, Chance MR, Lodowski D, An R. An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum. Heliyon 2024; 10:e34301. [PMID: 39149041 PMCID: PMC11324829 DOI: 10.1016/j.heliyon.2024.e34301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Accepted: 07/08/2024] [Indexed: 08/17/2024] Open
Abstract
Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0-4 mM) and artificial sweat (0-100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.
Collapse
Affiliation(s)
- Qingrong He
- Department of Biomedical Engineering, University of Houston, United States
| | - Cheng Wang
- Department of Biomedical Engineering, University of Houston, United States
| | - Rohit Jain
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Center for Proteomics and Bioinformatics, School of Medicine, Case Western Reserve University, United States
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, United States
| | - James Byrnes
- National Synchrotron Light Source II, Brookhaven National Laboratory, United States
| | - Erik R. Farquhar
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, United States
| | - Elliot Reed
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Sensate Biosystems LLC, Cleveland, OH, United States
| | - Elizabeth Berezovsky
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Sensate Biosystems LLC, Cleveland, OH, United States
| | - Mark R. Chance
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Center for Proteomics and Bioinformatics, School of Medicine, Case Western Reserve University, United States
- Center for Synchrotron Biosciences, School of Medicine, Case Western Reserve University, United States
- Sensate Biosystems LLC, Cleveland, OH, United States
| | - David Lodowski
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Center for Proteomics and Bioinformatics, School of Medicine, Case Western Reserve University, United States
- Sensate Biosystems LLC, Cleveland, OH, United States
| | - Ran An
- Department of Biomedical Engineering, University of Houston, United States
- Biomolecular Structure and Integration of Sensors (BioSIS) Program, Department of Nutrition, School of Medicine, Case Western Reserve University, United States
- Department of Biomedical Sciences, University of Houston, United States
| |
Collapse
|
26
|
Nalepa MA, Panáček D, Dědek I, Jakubec P, Kupka V, Hrubý V, Petr M, Otyepka M. Graphene derivative-based ink advances inkjet printing technology for fabrication of electrochemical sensors and biosensors. Biosens Bioelectron 2024; 256:116277. [PMID: 38613934 DOI: 10.1016/j.bios.2024.116277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 03/16/2024] [Accepted: 04/05/2024] [Indexed: 04/15/2024]
Abstract
The field of biosensing would significantly benefit from a disruptive technology enabling flexible manufacturing of uniform electrodes. Inkjet printing holds promise for this, although realizing full electrode manufacturing with this technology remains challenging. We introduce a nitrogen-doped carboxylated graphene ink (NGA-ink) compatible with commercially available printing technologies. The water-based and additive-free NGA-ink was utilized to produce fully inkjet-printed electrodes (IPEs), which demonstrated successful electrochemical detection of the important neurotransmitter dopamine. The cost-effectiveness of NGA-ink combined with a total cost per electrode of $0.10 renders it a practical solution for customized electrode manufacturing. Furthermore, the high carboxyl group content of NGA-ink (13 wt%) presents opportunities for biomolecule immobilization, paving the way for the development of advanced state-of-the-art biosensors. This study highlights the potential of NGA inkjet-printed electrodes in revolutionizing sensor technology, offering an affordable, scalable alternative to conventional electrochemical systems.
Collapse
Affiliation(s)
- Martin-Alex Nalepa
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic
| | - David Panáček
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic; Nanotechnology Centre, Centre of Energy and Environmental Technologies, VSB - Technical University of Ostrava, 17. listopadu 2172/15, 708 00, Ostrava-Poruba, Czech Republic
| | - Ivan Dědek
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic; Department of Physical Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 1192/12, Olomouc, 771 46, Czech Republic
| | - Petr Jakubec
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic
| | - Vojtěch Kupka
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic
| | - Vítězslav Hrubý
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic; Department of Physical Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 1192/12, Olomouc, 771 46, Czech Republic
| | - Martin Petr
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic
| | - Michal Otyepka
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 27, Olomouc, 783 71, Czech Republic; IT4Innovations, VSB - Technical University of Ostrava, 17. listopadu 2172/15, Ostrava-Poruba, 708 00, Czech Republic.
| |
Collapse
|
27
|
Tsvik L, Zhang S, O'Hare D, Haltrich D, Sützl L. More Than One Enzyme: Exploring Alternative FMN-Dependent L-Lactate Oxidases for Biosensor Development. ACS OMEGA 2024; 9:29442-29452. [PMID: 39005781 PMCID: PMC11238220 DOI: 10.1021/acsomega.4c01897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 06/05/2024] [Accepted: 06/14/2024] [Indexed: 07/16/2024]
Abstract
The α-hydroxy acid oxidoreductase (HAOx) family contains a diverse group of enzymes that can be applied in biosensors for L-lactate detection, most prominently lactate oxidase (LOx). The limited availability and a lack of diversity of L-lactate-oxidizing enzymes have currently hindered advancements in L-lactate biosensor development. Until now, the field has mostly relied on a single, commercially available enzyme, namely Aerococcus viridans L-lactate oxidase (AvLOx). In this study, we present newly discovered alternative L-lactate oxidases that exhibit a narrow substrate specificity and varied kinetic efficiencies toward L-lactate, making them suitable for integration into existing biosensor configurations. Some of these FMN-dependent L-lactate oxidases could be obtained in substantial amounts from routine E. coli expression, potentially facilitating commercial production. Using electrochemical characterization with a mediated biosensor setup, we present 7 enzymes that perform comparable or even better than commercial AvLOx. Finally, we show that their electrochemical performance is not directly correlating with their biochemical performance, making predictions of the suitability of enzymes for biosensor applications extremely difficult. Our research emphasizes the significance of expanding the enzyme toolbox of L-lactate oxidases for the development of improved L-lactate biosensors.
Collapse
Affiliation(s)
- Lidiia Tsvik
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences, Muthgasse 11, Wien, Vienna A-1190, Austria
- Doctoral Programme 'Biomolecular Technology of Proteins (BioToP)', University of Natural Resources and Life Sciences, Muthgasse 18, Wien, Vienna A-1190, Austria
| | - Shulin Zhang
- Department of Bioengineering, Imperial College London, London SW72AZ, U.K
| | - Danny O'Hare
- Department of Bioengineering, Imperial College London, London SW72AZ, U.K
| | - Dietmar Haltrich
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences, Muthgasse 11, Wien, Vienna A-1190, Austria
| | - Leander Sützl
- Laboratory of Food Biotechnology, Department of Food Science and Technology, University of Natural Resources and Life Sciences, Muthgasse 11, Wien, Vienna A-1190, Austria
| |
Collapse
|
28
|
Srikrishnarka P, Haapasalo J, Hinestroza JP, Sun Z, Nonappa. Wearable Sensors for Physiological Condition and Activity Monitoring. SMALL SCIENCE 2024; 4:2300358. [PMID: 40212111 PMCID: PMC11935081 DOI: 10.1002/smsc.202300358] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 04/10/2024] [Indexed: 04/13/2025] Open
Abstract
Rapid technological advancements have transformed the healthcare sector from traditional diagnosis and treatment to personalized health management. Biofluids such as teardrops, sweat, interstitial fluids, and exhaled breath condensate offer a rich source of metabolites that can be linked to the physiological status of an individual. More importantly, these biofluids contain biomarkers similar to those in the blood. Therefore, developing sensors for the noninvasive determination of biofluid-based metabolites can overcome traditionally invasive and laborious blood-test-based diagnostics. In this context, wearable devices offer real-time and continuous physiological conditions and activity monitoring. The first-generation wearables included wristwatches capable of tracking heart rate variations, breathing rate, body temperature, stress responses, and sleeping patterns. However, wearable sensors that can accurately measure the metabolites are needed to achieve real-time analysis of biomarkers. In this review, recent progresses in wearable sensors utilized to monitor metabolites in teardrops, breath condensate, sweat, and interstitial fluids are thoroughly analyzed. More importantly, how metabolites can be selectively detected, quantified, and monitored in real-time is discussed. Furthermore, the review includes a discussion on the utility of, multifunctional sensors that combine metabolite sensing, human activity monitoring, and on-demand drug delivery system for theranostic applications.
Collapse
Affiliation(s)
| | - Joonas Haapasalo
- Department of NeurosurgeryTampere University Hospital and Tampere UniversityKuntokatu 233520TampereFinland
| | - Juan P. Hinestroza
- Department of Fiber Science and Apparel DesignCornell UniversityIthacaNY14853USA
| | - Zhipei Sun
- Department of Electronics and NanoengineeringAalto UniversityP.O. Box 13500FI‐00076AaltoFinland
- QTF Center of ExcellenceDepartment of Applied PhysicsAalto University00076AaltoFinland
| | - Nonappa
- Faculty of Engineering and Natural SciencesKorkeakoulunkatu 6FI‐33720TampereFinland
| |
Collapse
|
29
|
Wang Q, Molinero-Fernandez Á, Wei Q, Xuan X, Konradsson-Geuken Å, Cuartero M, Crespo GA. Intradermal Lactate Monitoring Based on a Microneedle Sensor Patch for Enhanced In Vivo Accuracy. ACS Sens 2024; 9:3115-3125. [PMID: 38778463 PMCID: PMC11217941 DOI: 10.1021/acssensors.4c00337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 05/10/2024] [Accepted: 05/15/2024] [Indexed: 05/25/2024]
Abstract
Lactate is an important diagnostic and prognostic biomarker of several human pathological conditions, such as sepsis, malaria, and dengue fever. Unfortunately, due to the lack of reliable analytical decentralized platforms, the determination of lactate yet relies on discrete blood-based assays, which are invasive and inefficient and may cause tension and pain in the patient. Herein, we demonstrate the potential of a fully integrated microneedle (MN) sensing system for the minimally invasive transdermal detection of lactate in an interstitial fluid (ISF). The originality of this analytical technology relies on: (i) a strategy to provide a uniform coating of a doped polymer-based membrane as a diffusion-limiting layer on the MN structure, optimized to perform full-range lactate detection in the ISF (linear range of response: 0.25-35 mM, 30 s assay time, 8 h operation), (ii) double validation of ex vivo and in vivo results based on ISF and blood measurements in rats, (iii) monitoring of lactate level fluctuations under the administration of anesthesia to mimic bedside clinical scenarios, and (iv) in-house design and fabrication of a fully integrated and portable sensing device in the form of a wearable patch including a custom application and user-friendly interface in a smartphone for the rapid, routine, continuous, and real-time lactate monitoring. The main analytical merits of the lactate MN sensor include appropriate selectivity, reversibility, stability, and durability by using a two-electrode amperometric readout. The ex-vivo testing of the MN patch of preconditioned rat skin pieces and euthanized rats successfully demonstrated the accuracy in measuring lactate levels. The in vivo measurements suggested the existence of a positive correlation between ISF and blood lactate when a lag time of 10 min is considered (Pearson's coefficient = 0.85, mean difference = 0.08 mM). The developed MN-based platform offers distinct advantages over noncontinuous blood sampling in a wide range of contexts, especially where access to laboratory services is limited or blood sampling is not suitable. Implementation of the wearable patch in healthcare could envision personalized medicine in a variety of clinical settings.
Collapse
Affiliation(s)
- Qianyu Wang
- Department
of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| | - Águeda Molinero-Fernandez
- Department
of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
- UCAM-SENS,
Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - Qikun Wei
- Department
of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
| | - Xing Xuan
- Department
of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
- UCAM-SENS,
Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - Åsa Konradsson-Geuken
- Section
of Neuropharmacology and Addiction Research, Department of Pharmaceutical
Biosciences, Uppsala University, SE-751 05 Uppsala, Sweden
| | - María Cuartero
- Department
of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
- UCAM-SENS,
Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| | - Gastón A. Crespo
- Department
of Chemistry, KTH Royal Institute of Technology, Teknikringen 30, SE-114 28 Stockholm, Sweden
- UCAM-SENS,
Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andres Hernandez Ros 1, 30107 Murcia, Spain
| |
Collapse
|
30
|
Probst D, Sode K. Development of closed bipolar electrode based L-lactate sensor employing quasi-direct electron transfer type enzyme with cyclic voltammetry. Biosens Bioelectron 2024; 254:116197. [PMID: 38493528 DOI: 10.1016/j.bios.2024.116197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 02/22/2024] [Accepted: 03/06/2024] [Indexed: 03/19/2024]
Abstract
Herein, we present a proof-of-concept of an enzyme sensor combining closed bipolar electrode system with quasi-direct electron transfer (DET) type enzyme. The closed bipolar electrode system was tested using cyclic voltammetry, with L-lactate as a model substrate. L-Lactate was detected through measurement of the change in junction potential across the bipolar electrode. This change in junction potential was caused by reduction of amino reactive phenazine ethosulfate conjugated to Aerococcus vilidans derived engineered L-lactate oxidase (AvLOx) which shows a quasi-DET signal. Using the closed bipolar electrode system allowed simultaneous measuring using cyclic voltammetry and open circuit potential (OCP) and achieved a limit of detection of 400 μM and 76.2 μM lactate respectively. The sensor was then demonstrated to perform with equivalent sensitivity using OCP across varying surface areas. To the best of our knowledge this is the first time a closed bipolar electrode system has been used with an enzyme which is capable of quasi-direct or direct electron transfer. This work can be expanded further to other enzymes capable of directly altering the junction potential of an electrode surface.
Collapse
Affiliation(s)
- David Probst
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA
| | - Koji Sode
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, 27599, USA.
| |
Collapse
|
31
|
Tamiya E, Osaki S, Nagai H. Wireless electrochemiluminescent biosensors: Powering innovation with smartphone technology. Biosens Bioelectron 2024; 252:116083. [PMID: 38387231 DOI: 10.1016/j.bios.2024.116083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Revised: 01/21/2024] [Accepted: 01/26/2024] [Indexed: 02/24/2024]
Abstract
Energy supply and sensor response acquisition can be performed wirelessly, enabling biosensors as Internet of Thing (IoT) tools by linking wireless power supply and electrochemical sensors. Here, we used the electromagnetic induction method to clarify the conditions under which electrochemiluminescence is induced by a simple potential modulation circuit without an integrated circuit on the electrode chip that receives the power. Initially, the potential waveform obtained in a circuit with inductance and capacitance components that resonate with the transmission frequency and a diode for rectification was investigated to clarify the conditions inducing an electrochemiluminescence reaction at the printed electrode. A high-sensitivity complementary metal-oxide semiconductor camera built into the smartphone wirelessly detected the luminescence generated on the electrode chip. The images were quantitatively evaluated using open-source image analysis software which determine the sensitivity of detecting hydrogen peroxide. Glucose oxidase (GOD) encapsulated in a matrix of chitosan polymers and photocrosslinkable polymers was immobilized on a mass-producible and inexpensive printed electrode to maintain high activity. The immobilized membrane suppressed luminescence when immobilized on the working electrode; therefore, the enzyme was immobilized on the counter electrode for glucose measurement over a wide concentration. Thus, luminol electrochemiluminescence was induced on the electrode chip by wireless power supply from a smartphone. Human serum and artificial sweat samples were tested and indicated possibility for actual applications. In this way a fully wireless biosensor was developed with potential as an IoT biosensor.
Collapse
Affiliation(s)
- Eiichi Tamiya
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan; SANKEN, Osaka University, 8-1 Mihogaoka, Ibaraki 567-0047, Osaka, Japan.
| | - Shuto Osaki
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| | - Hidenori Nagai
- Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| |
Collapse
|
32
|
Konno S, Kudo H. Fundamental Study of a Wristwatch Sweat Lactic Acid Monitor. BIOSENSORS 2024; 14:187. [PMID: 38667180 PMCID: PMC11048019 DOI: 10.3390/bios14040187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 04/06/2024] [Accepted: 04/08/2024] [Indexed: 04/28/2024]
Abstract
A lactic acid (LA) monitoring system aimed at sweat monitoring was fabricated and tested. The sweat LA monitoring system uses a continuous flow of phosphate buffer saline, instead of chambers or cells, for collecting and storing sweat fluid excreted at the skin surface. To facilitate the use of the sweat LA monitoring system by subjects when exercising, the fluid control system, including the sweat sampling device, was designed to be unaffected by body movements or muscle deformation. An advantage of our system is that the skin surface condition is constantly refreshed by continuous flow. A real sample test was carried out during stationary bike exercise, which showed that LA secretion increased by approximately 10 μg/cm2/min compared to the baseline levels before exercise. The LA levels recovered to baseline levels after exercise due to the effect of continuous flow. This indicates that the wristwatch sweat LA monitor has the potential to enable a detailed understanding of the LA distribution at the skin surface.
Collapse
Affiliation(s)
| | - Hiroyuki Kudo
- Department of Electronics and Bioinformatics, School of Science and Technology, Meiji University, Tokyo 214-8571, Kanagawa, Japan
| |
Collapse
|
33
|
Tseng HS, Chen YL, Zhang PY, Hsiao YS. Additive Blending Effects on PEDOT:PSS Composite Films for Wearable Organic Electrochemical Transistors. ACS APPLIED MATERIALS & INTERFACES 2024; 16:13384-13398. [PMID: 38454789 PMCID: PMC10958448 DOI: 10.1021/acsami.3c14961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 02/17/2024] [Accepted: 02/21/2024] [Indexed: 03/09/2024]
Abstract
Organic electrochemical transistors (OECTs) employing conductive polymers (CPs) have gained remarkable prominence and have undergone extensive advancements in wearable and implantable bioelectronic applications in recent years. Among the diverse arrays of CPs, poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) is a common choice for the active-layer channel in p-type OECTs, showing a remarkably high transconductance for the high amplification of signals in biosensing applications. This investigation focuses on the novel engineering of PEDOT:PSS composite materials by seamlessly integrating several additives, namely, dimethyl sulfoxide (DMSO), (3-glycidyloxypropyl)trimethoxysilane (GOPS), and a nonionic fluorosurfactant (NIFS), to fine-tune their electrical conductivity, self-healing capability, and stretchability. To elucidate the intricate influences of the DMSO, GOPS, and NIFS additives on the formation of PEDOT:PSS composite films, theoretical calculations were performed, encompassing the solubility parameters and surface energies of the constituent components of the NIFS, PEDOT, PSS, and PSS-GOPS polymers. Furthermore, we conducted a comprehensive array of material analyses, which reveal the intricacies of the phase separation phenomenon and its interaction with the materials' characteristics. Our research identified the optimal composition for the PEDOT:PSS composite films, characterized by outstanding self-healing and stretchable capabilities. This composition has proven to be highly effective for constructing an active-layer channel in the form of OECT-based biosensors fabricated onto polydimethylsiloxane substrates for detecting dopamine. Overall, these findings represent significant progress in the application of PEDOT:PSS composite films in wearable bioelectronics and pave the way for the development of state-of-the-art biosensing technologies.
Collapse
Affiliation(s)
- Hsueh-Sheng Tseng
- Department of Materials Science
and Engineering, National Taiwan University
of Science and Technology, Taipei 10607, Taiwan
| | - Ying-Lin Chen
- Department of Materials Science
and Engineering, National Taiwan University
of Science and Technology, Taipei 10607, Taiwan
| | - Pin-Yu Zhang
- Department of Materials Science
and Engineering, National Taiwan University
of Science and Technology, Taipei 10607, Taiwan
| | - Yu-Sheng Hsiao
- Department of Materials Science
and Engineering, National Taiwan University
of Science and Technology, Taipei 10607, Taiwan
| |
Collapse
|
34
|
Khan R, Andreescu S. Catalytic MXCeO 2 for enzyme based electrochemical biosensors: Fabrication, characterization and application towards a wearable sweat biosensor. Biosens Bioelectron 2024; 248:115975. [PMID: 38159417 DOI: 10.1016/j.bios.2023.115975] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 12/23/2023] [Accepted: 12/25/2023] [Indexed: 01/03/2024]
Abstract
Two-dimensional (2D) layered materials that integrate metallic conductivity, catalytic activity and the ability to stabilize biological receptors provide unique capabilities for designing electrochemical biosensors for large-scale detection and diagnostic applications. Herein, we report a multifunctional MXene-based 2D nanostructure decorated with enzyme mimetic cerium oxide nanoparticle (MXCeO2) as a novel platform and catalytic amplifier for electrochemical biosensors, specifically targeting the detection of oxidase enzyme substrates. We demonstrate enhanced catalytic efficiency of the MXCeO2 for the reduction of hydrogen peroxide (H2O2) and its ability to immobilize oxidase enzymes, such as glucose oxidase, lactate oxidase and xanthine oxidase. The designed biosensors exhibit high selectivity, stability, and sensitivity, achieving detection limits of 0.8 μM H2O2, 0.49 μM glucose, 3.6 μM lactate and 1.7 μM hypoxanthine, when the MXCeO2 and their respective enzymes were used. The MXCeO2 was successfully incorporated into a wearable fabric demonstrating high sensitivity for lactate measurements in sweat. The unique combination of MXenes with CeO2 offers excellent conductivity, catalytic efficiency and enhanced enzyme loading, demonstrating potential of the MXCeO2 as a catalytically active material to boost efficiency of oxidase enzyme reactions. This design can be used as a general platform for increasing the sensitivity of enzyme based biosensors and advance the development of electrochemical biosensors for a variety of applications.
Collapse
Affiliation(s)
- Reem Khan
- Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY, 13699, United States
| | - Silvana Andreescu
- Department of Chemistry and Biomolecular Science, Clarkson University, 8 Clarkson Avenue, Potsdam, NY, 13699, United States.
| |
Collapse
|
35
|
Saha T, Mukherjee S, Dickey MD, Velev OD. Harvesting and manipulating sweat and interstitial fluid in microfluidic devices. LAB ON A CHIP 2024; 24:1244-1265. [PMID: 38197332 DOI: 10.1039/d3lc00874f] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
Abstract
Microfluidic devices began to be used to facilitate sweat and interstitial fluid (ISF) sensing in the mid-2010s. Since then, numerous prototypes involving microfluidics have been developed in different form factors for sensing biomarkers found in these fluids under in vitro, ex vivo, and in vivo (on-body) settings. These devices transport and manipulate biofluids using microfluidic channels composed of silicone, polymer, paper, or fiber. Fluid flow transport and sample management can be achieved by controlling the flow rate, surface morphology of the channel, and rate of fluid evaporation. Although many devices have been developed for estimating sweat rate, electrolyte, and metabolite levels, only a handful have been able to proceed beyond laboratory testing and reach the stage of clinical trials and commercialization. To further this technology, this review reports on the utilization of microfluidics towards sweat and ISF management and transport. The review is distinguished from other recent reviews by focusing on microfluidic principles of sweat and ISF generation, transport, extraction, and management. Challenges and prospects are highlighted, with a discussion on how to transition such prototypes towards personalized healthcare monitoring systems.
Collapse
Affiliation(s)
- Tamoghna Saha
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| | - Sneha Mukherjee
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| | - Michael D Dickey
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| | - Orlin D Velev
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| |
Collapse
|
36
|
Wu ZQ, Cao XQ, Hua Y, Yu CM. A Bifunctional Wearable Sensor Based on a Nanoporous Membrane for Simultaneous Detection of Sweat Lactate and Temperature. Anal Chem 2024. [PMID: 38320230 DOI: 10.1021/acs.analchem.3c05216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2024]
Abstract
Wearable sensors for non-invasive, real-time detection of sweat lactate have far-reaching implications in the fields of health care and exercise physiological responses. Here, we propose a wearable electrochemical sensor with gold nanoelectrode arrays fabricated on the nanoporous polycarbonate (PC) membrane by encapsulating lactate oxidase (LOx) in chitosan (CS) hydrogel for detecting body temperature and sweat lactate concurrently. Flexible gold nanoporous electrodes not only enhance electrode area but also offer a nanoconfined space to accelerate the catalytic reaction of LOx and control substrate concentration on the surface of LOx to decrease substrate inhibition. The proposed sensor has a long durability of 13 days and better selectivity for the detection of sweat lactate over a wide linear range (0.01-35 mM) with a low detection limit (0.144 μM). Furthermore, temperature-dependent transmembrane currents passing through the sensor are used to estimate body temperature. We then use multiple linear regression to adjust the effect of temperature on lactate detection and succeed in monitoring lactate molecules in sweat and body temperature during exercise.
Collapse
Affiliation(s)
- Zeng-Qiang Wu
- School of Public Health, Nantong University, Nantong, Jiangsu 226019, China
| | - Xiao-Qing Cao
- School of Public Health, Nantong University, Nantong, Jiangsu 226019, China
| | - Yu Hua
- School of Public Health, Nantong University, Nantong, Jiangsu 226019, China
| | - Chun-Mei Yu
- School of Public Health, Nantong University, Nantong, Jiangsu 226019, China
| |
Collapse
|
37
|
Du Y, Reitemeier J, Jiang Q, Bappy MO, Bohn PW, Zhang Y. Hybrid Printing of Fully Integrated Microfluidic Devices for Biosensing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2304966. [PMID: 37752777 DOI: 10.1002/smll.202304966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 08/22/2023] [Indexed: 09/28/2023]
Abstract
The advent of 3D printing has facilitated the rapid fabrication of microfluidic devices that are accessible and cost-effective. However, it remains a challenge to fabricate sophisticated microfluidic devices with integrated structural and functional components due to limited material options of existing printing methods and their stringent requirement on feedstock material properties. Here, a multi-materials multi-scale hybrid printing method that enables seamless integration of a broad range of structural and functional materials into complex devices is reported. A fully printed and assembly-free microfluidic biosensor with embedded fluidic channels and functionalized electrodes at sub-100 µm spatial resolution for the amperometric sensing of lactate in sweat is demonstrated. The sensors present a sensitive response with a limit of detection of 442 nm and a linear dynamic range of 1-10 mm, which are performance characteristics relevant to physiological levels of lactate in sweat. The versatile hybrid printing method offers a new pathway toward facile fabrication of next-generation integrated devices for broad applications in point-of-care health monitoring and sensing.
Collapse
Affiliation(s)
- Yipu Du
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Julius Reitemeier
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Qiang Jiang
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Md Omarsany Bappy
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Paul W Bohn
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, IN, 46556, USA
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| | - Yanliang Zhang
- Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, IN, 46556, USA
| |
Collapse
|
38
|
Watkins Z, McHenry A, Heikenfeld J. Wearing the Lab: Advances and Challenges in Skin-Interfaced Systems for Continuous Biochemical Sensing. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2024; 187:223-282. [PMID: 38273210 DOI: 10.1007/10_2023_238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2024]
Abstract
Continuous, on-demand, and, most importantly, contextual data regarding individual biomarker concentrations exemplify the holy grail for personalized health and performance monitoring. This is well-illustrated for continuous glucose monitoring, which has drastically improved outcomes and quality of life for diabetic patients over the past 2 decades. Recent advances in wearable biosensing technologies (biorecognition elements, transduction mechanisms, materials, and integration schemes) have begun to make monitoring of other clinically relevant analytes a reality via minimally invasive skin-interfaced devices. However, several challenges concerning sensitivity, specificity, calibration, sensor longevity, and overall device lifetime must be addressed before these systems can be made commercially viable. In this chapter, a logical framework for developing a wearable skin-interfaced device for a desired application is proposed with careful consideration of the feasibility of monitoring certain analytes in sweat and interstitial fluid and the current development of the tools available to do so. Specifically, we focus on recent advancements in the engineering of biorecognition elements, the development of more robust signal transduction mechanisms, and novel integration schemes that allow for continuous quantitative analysis. Furthermore, we highlight the most compelling and promising prospects in the field of wearable biosensing and the challenges that remain in translating these technologies into useful products for disease management and for optimizing human performance.
Collapse
Affiliation(s)
- Zach Watkins
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA.
| | - Adam McHenry
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| | - Jason Heikenfeld
- Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
| |
Collapse
|
39
|
Roychoudhury A, Raj R. Role of 3D printing in microfluidics and applications. NEXT-GENERATION SMART BIOSENSING 2024:67-107. [DOI: 10.1016/b978-0-323-98805-6.00004-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
|
40
|
Parupelli SK, Desai S. The 3D Printing of Nanocomposites for Wearable Biosensors: Recent Advances, Challenges, and Prospects. Bioengineering (Basel) 2023; 11:32. [PMID: 38247910 PMCID: PMC10813523 DOI: 10.3390/bioengineering11010032] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/11/2023] [Accepted: 12/20/2023] [Indexed: 01/23/2024] Open
Abstract
Notably, 3D-printed flexible and wearable biosensors have immense potential to interact with the human body noninvasively for the real-time and continuous health monitoring of physiological parameters. This paper comprehensively reviews the progress in 3D-printed wearable biosensors. The review also explores the incorporation of nanocomposites in 3D printing for biosensors. A detailed analysis of various 3D printing processes for fabricating wearable biosensors is reported. Besides this, recent advances in various 3D-printed wearable biosensors platforms such as sweat sensors, glucose sensors, electrocardiography sensors, electroencephalography sensors, tactile sensors, wearable oximeters, tattoo sensors, and respiratory sensors are discussed. Furthermore, the challenges and prospects associated with 3D-printed wearable biosensors are presented. This review is an invaluable resource for engineers, researchers, and healthcare clinicians, providing insights into the advancements and capabilities of 3D printing in the wearable biosensor domain.
Collapse
Affiliation(s)
- Santosh Kumar Parupelli
- Department of Industrial and Systems Engineering, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA;
- Center of Excellence in Product Design and Advanced Manufacturing, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| | - Salil Desai
- Department of Industrial and Systems Engineering, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA;
- Center of Excellence in Product Design and Advanced Manufacturing, North Carolina Agricultural and Technical State University, Greensboro, NC 27411, USA
| |
Collapse
|
41
|
Hernández-Rodríguez JF, Rojas D, Escarpa A. Print-Pause-Print Fabrication of Tailored Electrochemical Microfluidic Devices. Anal Chem 2023; 95:18679-18684. [PMID: 38095628 PMCID: PMC10753525 DOI: 10.1021/acs.analchem.3c03364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 11/23/2023] [Accepted: 11/24/2023] [Indexed: 12/27/2023]
Abstract
Three-dimensional (3D) printing technology has emerged as a powerful technology for the fabrication of low-cost microfluidics. Nevertheless, the fabrication of microfluidic devices integrating high-performance electrochemical sensors in practical applications is still an open challenge. Although automatic fabrication of the microfluidic device and the electrodes can be successfully carried out using a one-step multimaterial fused filament fabrication (FFF) approach, the as-printed electrochemical performance of these electrodes is not good enough for chemical (bio)sensing and their surface modification is challenging because after closing the channel there is no physical access to the electrode. Thus, here a pause-print-pause (PPP) microfabrication approach was implemented. The fabrication was paused before printing the microfluidics, and the filament-based electrodes were directly modified on the printing bed via stencil printing, drop casting, and electrodeposition. To exemplify this versatile workflow, the design of a microfluidic glucose sensor was proposed. To this end, first, the working and counter electrodes were stencil printed with graphite ink while the reference electrode was stencil printed with Ag|AgCl ink. Then, Prussian blue was formed on the working electrode either by drop casting or by electrodeposition, and glucose oxidase was drop cast on top. At this point, the microfabrication process was resumed, and the microfluidics were printed on top of the modified electrodes to complete the construction of hybrid electrochemical fluidic fused filament fabricated devices (h-eF4Ds). This print-pause-print approach is not limited to ink-based electrodes or glucose oxidase, and we envisage these results will pave the way for the effective integration of electrodes in microfluidic devices in a simple and clean-room-free approach, allowing the development of highly customized eF4Ds for a plethora of analytes with high significance.
Collapse
Affiliation(s)
- Juan F. Hernández-Rodríguez
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
| | - Daniel Rojas
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
| | - Alberto Escarpa
- Department
of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
- Chemical
Research Institute “Andres M. Del Rio”, University of Alcalá, Alcalá de Henares, 28805 Madrid, Spain
| |
Collapse
|
42
|
Zhou D, Zhang S, Khan AU, Chen L, Ge G. A wearable AuNP enhanced metal-organic gel (Au@MOG) sensor for sweat glucose detection with ultrahigh sensitivity. NANOSCALE 2023; 16:163-170. [PMID: 38073477 DOI: 10.1039/d3nr05179j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2023]
Abstract
The demand for sensitive and non-invasive sensors for monitoring glucose levels in sweat has grown considerably in recent years. This study presents the development of a wearable sensor for sweat glucose detection with ultrahigh sensitivity. The sensor was fabricated by embedding Au nanoparticles (AuNPs) and metal-organic gels (MOGs) on nickel foam (NF). A non-enzymatic electrocatalytic glucose sensor has been developed to combine the three-dimensional network of MOGs with more active sites favourable for glucose diffusion and the transfer of electrons from glucose to the electrode. These results show that the sensor has an ultrahigh sensitivity of 13.94 mA mM-1 cm-2, a linear detection range between 2 and 600 μM, and a lower detection limit as low as 1 μM (signal/noise = 3) with comparable accuracy and reliability under non-alkaline conditions to those of high-pressure ion chromatography (HPIC). Furthermore, a wearable sweat glucose sensor has been constructed by sputtering an Au conductive layer on a flexible polydimethylsiloxane (PDMS) substrate and coating it with Au@MOGs. Our work demonstrates that the combination of Au NPs and MOGs can enhance the sensitivity and activity of these materials, making them useful for electrocatalytic glucose monitoring with ultrahigh sensitivity.
Collapse
Affiliation(s)
- Dengfeng Zhou
- CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 ZhongguancunBeiyitiao, Beijing 100190, PR China.
- University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Shuangbin Zhang
- CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 ZhongguancunBeiyitiao, Beijing 100190, PR China.
- University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Atta Ullah Khan
- CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 ZhongguancunBeiyitiao, Beijing 100190, PR China.
- University of Chinese Academy of Sciences, Beijing 100049, PR China
| | - Lan Chen
- CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 ZhongguancunBeiyitiao, Beijing 100190, PR China.
| | - Guanglu Ge
- CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, No. 11 ZhongguancunBeiyitiao, Beijing 100190, PR China.
| |
Collapse
|
43
|
Ali N, Rahat ST, Mäkelä M, Nasserinejad M, Jaako T, Kinnunen M, Schroderus J, Tulppo M, Nieminen AI, Vainio S. Metabolic patterns of sweat-extracellular vesicles during exercise and recovery states using clinical grade patches. Front Physiol 2023; 14:1295852. [PMID: 38143912 PMCID: PMC10748597 DOI: 10.3389/fphys.2023.1295852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 11/28/2023] [Indexed: 12/26/2023] Open
Abstract
Background: Metabolite-based sensors are attractive and highly valued for monitoring physiological parameters during rest and/or during physical activities. Owing to their molecular composition consisting of nucleic acids, proteins, and metabolites, extracellular vesicles (EVs) have become acknowledged as a novel tool for disease diagnosis. However, the evidence for sweat related EVs delivering information of physical and recovery states remains to be addressed. Methods: Taking advantage of our recently published methodology allowing the enrichment and isolation of sweat EVs from clinical patches, we investigated the metabolic load of sweat EVs in healthy participants exposed to exercise test or recovery condition. -Ten healthy volunteers (-three females and -seven males) were recruited to participate in this study. During exercise test and recovery condition, clinical patches were attached to participants' skin, on their back. Following exercise test or recovery condition, the patches were carefully removed and proceed for sweat EVs isolation. To explore the metabolic composition of sweat EVs, a targeted global metabolomics profiling of 41 metabolites was performed. Results: Our results identified seventeen metabolites in sweat EVs. These are associated with amino acids, glutamate, glutathione, fatty acids, creatine, and glycolysis pathways. Furthermore, when comparing the metabolites' levels in sweat EVs isolated during exercise to the metabolite levels in sweat EVs collected after recovery, our findings revealed a distinct metabolic profiling of sweat EVs. Furthermore, the level of these metabolites, mainly myristate, may reflect an inverse correlation with blood glucose, heart rate, and respiratory rate levels. Conclusion: Our data demonstrated that sweat EVs can be purified using routinely used clinical patches during physical activity, setting the foundations for larger-scale clinical cohort work. Furthermore, the metabolites identified in sweat EVs also offer a realistic means to identify relevant sport performance biomarkers. This study thus provides proof-of-concept towards a novel methodology that will focus on the use of sweat EVs and their metabolic composition as a non-invasive approach for developing the next-generation of sport wearable sensors.
Collapse
Affiliation(s)
- Nsrein Ali
- Laboratory of Developmental Biology, Faculty of Biochemistry and Molecular Medicine, Oulu, Finland
- Infotech Oulu, Oulu, Finland
- Flagship GeneCellNano, University of Oulu, Oulu, Finland
- Netskinmodels Cost Action CA21108, Oulu, Finland
| | - Syeda Tayyiba Rahat
- Laboratory of Developmental Biology, Faculty of Biochemistry and Molecular Medicine, Oulu, Finland
| | - Mira Mäkelä
- Laboratory of Developmental Biology, Faculty of Biochemistry and Molecular Medicine, Oulu, Finland
| | - Maryam Nasserinejad
- Infotech Oulu, Oulu, Finland
- Research Unit of Population Health Research, Research Center, Faculty of Medicine, University of Oulu, Oulu, Finland
| | | | | | | | - Mikko Tulppo
- Edical Research Center Oulu, Faculty of Medicine, University of Oulu, Oulu, Finland
- Resaerch Unit of Biomedicine and Internal Medicine, Faculty of Medicine, University of Oulu, Oulu, Finland
| | - Anni I. Nieminen
- FIMM Metabolomics Unit, Institute for Molecular Medicine Finland, University of Helsinki, Oulu, Finland
| | - Seppo Vainio
- Laboratory of Developmental Biology, Faculty of Biochemistry and Molecular Medicine, Oulu, Finland
- Infotech Oulu, Oulu, Finland
- Flagship GeneCellNano, University of Oulu, Oulu, Finland
- Netskinmodels Cost Action CA21108, Oulu, Finland
- Kvantum Institute, University of Oulu, Oulu, Finland
| |
Collapse
|
44
|
Saha T, Del Caño R, De la Paz E, Sandhu SS, Wang J. Access and Management of Sweat for Non-Invasive Biomarker Monitoring: A Comprehensive Review. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2206064. [PMID: 36433842 DOI: 10.1002/smll.202206064] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/07/2022] [Indexed: 06/16/2023]
Abstract
Sweat is an important biofluid presents in the body since it regulates the internal body temperature, and it is relatively easy to access on the skin unlike other biofluids and contains several biomarkers that are also present in the blood. Although sweat sensing devices have recently displayed tremendous progress, most of the emerging devices primarily focus on the sensor development, integration with electronics, wearability, and data from in vitro studies and short-term on-body trials during exercise. To further the advances in sweat sensing technology, this review aims to present a comprehensive report on the approaches to access and manage sweat from the skin toward improved sweat collection and sensing. It is begun by delineating the sweat secretion mechanism through the skin, and the historical perspective of sweat, followed by a detailed discussion on the mechanisms governing sweat generation and management on the skin. It is concluded by presenting the advanced applications of sweat sensing, supported by a discussion of robust, extended-operation epidermal wearable devices aiming to strengthen personalized healthcare monitoring systems.
Collapse
Affiliation(s)
- Tamoghna Saha
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| | - Rafael Del Caño
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
- Department of Physical Chemistry and Applied Thermodynamics, University of Cordoba, Cordoba, E-14014, Spain
| | - Ernesto De la Paz
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| | - Samar S Sandhu
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego La Jolla, California, CA, 92093, USA
| |
Collapse
|
45
|
Khosravi H, Carreras-Gallo O, Casals-Terré J. Mill Scale-Derived Magnetite Nanoparticles: A Novel Substrate for Lactate Oxidase-Based Biosensors. BIOSENSORS 2023; 13:957. [PMID: 37998132 PMCID: PMC10669300 DOI: 10.3390/bios13110957] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/24/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023]
Abstract
Recycling and revalorization of waste are currently essential for sustainable growth. Mill scale, a waste product from steel production industries, which contains high levels of iron and minimal impurities, is proposed in this study as the source to synthesize magnetite nanoparticles (Fe3O4) for an enhancement of a lactate biosensor range. The synthesized Fe3O4 nanoparticles were coated with polydopamine (PDA) to prevent aggregation and degradation, creating a stable platform for immobilizing lactate oxidase enzyme (LOx) on their surfaces. The characterization of the Fe3O4@PDA material was carried out using transmission electron microscopy (TEM), dynamic light scattering (DLS), and measurement of the polydispersity index (PdI). The Fe3O4@PDA-LOx material was then deposited on a screen-printed carbon electrode modified with Prussian blue (SPCE-PB) for lactate detection. The biosensor exhibited a broad, dual linear concentration-response range, one from 0.1 to 4.62 mM with a limit of detection of 0.32 mM and sensitivity of 1.54 μAmM-1cm-2, and another one from 4.62 to 149.21 mM with a limit of detection of 6.31 mM and sensitivity of 0.08 μAmM-1cm-2. The dual-range concentration response of the biosensor makes it an ideal tool for lactate determination in various applications, including sports medicine, clinical diagnosis, and industrial bioprocessing.
Collapse
Affiliation(s)
- Hamid Khosravi
- Department of Mechanical Engineering, Polytechnic University of Catalonia-BarcelonaTech (UPC), 08222 Terrassa, Barcelona, Spain;
| | - Oscar Carreras-Gallo
- Department of Innovation, Barnasteel S.A., 08755 Castellbisbal, Barcelona, Spain;
| | - Jasmina Casals-Terré
- Department of Mechanical Engineering, Polytechnic University of Catalonia-BarcelonaTech (UPC), 08222 Terrassa, Barcelona, Spain;
| |
Collapse
|
46
|
Kato Y, Iwata S, Nasu Y, Obata A, Nagata K, Campbell RE, Mizuno T. Construction of the lactate-sensing fibremats by confining sensor fluorescent protein of lactate inside nanofibers of the poly(HPMA/DAMA)/ADH-nylon 6 core-shell fibremat. RSC Adv 2023; 13:29584-29593. [PMID: 37822650 PMCID: PMC10562976 DOI: 10.1039/d3ra06108f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 10/03/2023] [Indexed: 10/13/2023] Open
Abstract
The development of a new materials platform capable of sustaining the functionality of proteinous sensor molecules over an extended period without being affected by biological contaminants in living systems, such as proteases, is highly demanded. In this study, our primary focus was on fabricating new core-shell fibremats using unique polymer materials, capable of functionalizing encapsulated sensor proteins while resisting the effects of proteases. The core-fibre parts of core-shell fibremats were made using a newly developed post-crosslinkable water-soluble copolymer, poly(2-hydroxypropyl methacrylamide)-co-poly(diacetone methacrylamide), and the bifunctional crosslinking agent, adipic dihydrazide, while the shell layer of the nanofibers was made of nylon 6. Upon encapsulating the lactate-sensor protein eLACCO1.1 at the core-fibre part, the fibremat exhibited a distinct concentration-dependent fluorescence response, with a dynamic range of fluorescence alteration exceeding 1000% over the lactate concentration range of 0 to 100 mM. The estimated dissociation constant from the titration data was comparable to that estimated in a buffer solution. The response remained stable even after 5 cycles and in the presence of proteases. These results indicates that our core-shell fibremat platform could serve as effective immobilizing substrates for various sensor proteins, facilitating continuous and quantitative monitoring of various low-molecular-weight metabolites and catabolites in a variety of biological samples.
Collapse
Affiliation(s)
- Yuna Kato
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology Gokiso-cho, Showa-ku Nagoya Aichi 466-8555 Japan
| | - Shuichi Iwata
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology Gokiso-cho, Showa-ku Nagoya Aichi 466-8555 Japan
| | - Yusuke Nasu
- Department of Chemistry, School of Science, The University of Tokyo Bunkyo-ku Tokyo 113-0033 Japan
| | - Akiko Obata
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology Gokiso-cho, Showa-ku Nagoya Aichi 466-8555 Japan
| | - Kenji Nagata
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology Gokiso-cho, Showa-ku Nagoya Aichi 466-8555 Japan
| | - Robert E Campbell
- Department of Chemistry, School of Science, The University of Tokyo Bunkyo-ku Tokyo 113-0033 Japan
| | - Toshihisa Mizuno
- Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology Gokiso-cho, Showa-ku Nagoya Aichi 466-8555 Japan
- Department of Nanopharmaceutical Sciences, Graduate School of Engineering, Nagoya Institute of Technology Gokiso-cho, Showa-ku Nagoya Aichi 466-8555 Japan
| |
Collapse
|
47
|
Tu J, Min J, Song Y, Xu C, Li J, Moore J, Hanson J, Hu E, Parimon T, Wang TY, Davoodi E, Chou TF, Chen P, Hsu JJ, Rossiter HB, Gao W. A wireless patch for the monitoring of C-reactive protein in sweat. Nat Biomed Eng 2023; 7:1293-1306. [PMID: 37349389 PMCID: PMC10592261 DOI: 10.1038/s41551-023-01059-5] [Citation(s) in RCA: 108] [Impact Index Per Article: 54.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 05/19/2023] [Indexed: 06/24/2023]
Abstract
The quantification of protein biomarkers in blood at picomolar-level sensitivity requires labour-intensive incubation and washing steps. Sensing proteins in sweat, which would allow for point-of-care monitoring, is hindered by the typically large interpersonal and intrapersonal variations in its composition. Here we report the design and performance of a wearable and wireless patch for the real-time electrochemical detection of the inflammatory biomarker C-reactive (CRP) protein in sweat. The device integrates iontophoretic sweat extraction, microfluidic channels for sweat sampling and for reagent routing and replacement, and a graphene-based sensor array for quantifying CRP (via an electrode functionalized with anti-CRP capture antibodies-conjugated gold nanoparticles), ionic strength, pH and temperature for the real-time calibration of the CRP sensor. In patients with chronic obstructive pulmonary disease, with active or past infections or who had heart failure, the elevated concentrations of CRP measured via the patch correlated well with the protein's levels in serum. Wearable biosensors for the real-time sensitive analysis of inflammatory proteins in sweat may facilitate the management of chronic diseases.
Collapse
Affiliation(s)
- Jiaobing Tu
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Jihong Min
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Yu Song
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Changhao Xu
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Jiahong Li
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Jeff Moore
- Division of Respiratory and Critical Care Physiology and Medicine, The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, Torrance, CA, USA
| | - Justin Hanson
- Division of Cardiology, University of California Los Angeles, Los Angeles, CA, USA
| | - Erin Hu
- Division of Cardiology, University of California Los Angeles, Los Angeles, CA, USA
| | - Tanyalak Parimon
- Department of Medicine, Women's Guild Lung Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Ting-Yu Wang
- Proteome Exploration Laboratory, Beckman Institute, California Institute of Technology, Pasadena, CA, USA
| | - Elham Davoodi
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Tsui-Fen Chou
- Proteome Exploration Laboratory, Beckman Institute, California Institute of Technology, Pasadena, CA, USA
| | - Peter Chen
- Department of Medicine, Women's Guild Lung Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Jeffrey J Hsu
- Division of Cardiology, University of California Los Angeles, Los Angeles, CA, USA
| | - Harry B Rossiter
- Division of Respiratory and Critical Care Physiology and Medicine, The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, Torrance, CA, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA.
| |
Collapse
|
48
|
Futane A, Senthil M, S J, Srinivasan A, R K, Narayanamurthy V. Sweat analysis for urea sensing: trends and challenges. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4405-4426. [PMID: 37646163 DOI: 10.1039/d3ay01089a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
With increasing population there is a rise in pathological diseases that the healthcare facilities are grappling with. Sweat-based wearable technologies for continuous monitoring have overcome the demerits associated with sweat sampling and sensing. Hence, sweat as an alternative biofluid holds great promise for the quantification of a host of biomarkers and understanding the functioning of the body, thereby deducing ailments quickly and economically. This comprehensive review accounts for recent advances in sweat-based LOCs (Lab-On-Chips), which are a likely alternative to the existing blood-urea sample testing that is invasive and time-consuming. The present review is focused on the advancements in sweat-based Lab-On-Chips (LOCs) as an alternative to invasive and time-consuming blood-urea sample testing. In addition, different sweat collection methods (direct skin, near skin and microfluidic) and their mechanism for urea sensing are explained in detail. The mechanism of urea in biofluids in protein metabolism, balancing nitrogen levels and a crucial factor of kidney function is described. In the end, research and technological advancements are explained to address current challenges and enable its widespread implementation.
Collapse
Affiliation(s)
- Abhishek Futane
- Fakulti Kejuruteraan Elektronik dan Kejuruteraan Komputer, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100 Durian Tunggal, Melaka, Malaysia
| | - Mallika Senthil
- Department of Biomedical Engineering, Rajalakshmi Engineering, College, Chennai, India 602105
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | - Jayashree S
- Department of Biomedical Engineering, Rajalakshmi Engineering, College, Chennai, India 602105
| | - Arthi Srinivasan
- Faculty of Chemical and Process Engineering Technology, University Malaysia Pahang (UMP), Lebuhraya Tun Razak, 26300 Gambang, Kunatan, Pahang, Malaysia
| | - Kalpana R
- Department of Biomedical Engineering, Rajalakshmi Engineering, College, Chennai, India 602105
| | - Vigneswaran Narayanamurthy
- Advance Sensors and Embedded Systems (ASECs), Centre for Telecommunication Research & Innovation, Fakulti Teknologi Kejuruteraan Elektrik Dan Elektronik, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, Durian Tunggal, Melaka 76100, Malaysia
- Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, India.
| |
Collapse
|
49
|
Abdullah IH, Wilson DJ, Mora AC, Parker RW, Mace CR. Generating signals at converging liquid fronts to create line-format readouts of soluble assay products in three-dimensional paper-based devices. LAB ON A CHIP 2023; 23:4010-4018. [PMID: 37581363 DOI: 10.1039/d3lc00511a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/16/2023]
Abstract
The correct interpretation of the result from a point-of-care device is crucial for an accurate and rapid diagnosis to guide subsequent treatment. Lateral flow tests (LFTs) use a well-established format that was designed to simplify the user experience. However, the LFT device architecture is inherently limited to detecting analytes that can be captured by molecular recognition. Microfluidic paper-based analytical devices (μPADs), like LFTs, have the potential to be used in diagnostic applications at the point of care. However, μPADs have not gained significant traction outside of academic laboratories, in part, because they have often demonstrated a lack of homogeneous shape or color in signal outputs, which consequently can lead to inaccurate interpretation of results by users. Here, we demonstrate a new class of μPADs that form colorimetric signals at the interfaces of converging liquid fronts (i.e., lines) to control where colorimetric signals are formed without relying on capture techniques. We demonstrate our approach by developing assays for three classes of analytes-an ion, an enzyme, and a small molecule-to measure using iron(III), acetylcholinesterase, and lactate, respectively. Additionally, we show these devices have the potential to support multiplexed assays by generating multiple lines in a common readout zone. These results highlight the ability of this new paper-based device architecture to aid the interpretation of assays that create soluble products by using flow to constrain those colorimetric products in a familiar, line-format output.
Collapse
Affiliation(s)
| | - Daniel J Wilson
- Department of Chemistry, Tufts University, Medford, MA 02155, USA.
| | - Andrea C Mora
- Department of Chemistry, Tufts University, Medford, MA 02155, USA.
| | | | - Charles R Mace
- Department of Chemistry, Tufts University, Medford, MA 02155, USA.
| |
Collapse
|
50
|
Mukasa D, Wang M, Min J, Yang Y, Solomon SA, Han H, Ye C, Gao W. A Computationally Assisted Approach for Designing Wearable Biosensors toward Non-Invasive Personalized Molecular Analysis. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2212161. [PMID: 37159949 PMCID: PMC10529901 DOI: 10.1002/adma.202212161] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 04/26/2023] [Indexed: 05/11/2023]
Abstract
Wearable sweat sensors have the potential to revolutionize precision medicine as they can non-invasively collect molecular information closely associated with an individual's health status. However, the majority of clinically relevant biomarkers cannot be continuously detected in situ using existing wearable approaches. Molecularly imprinted polymers (MIPs) are a promising candidate to address this challenge but haven't yet gained widespread use due to their complex design and optimization process yielding variable selectivity. Here, QuantumDock is introduced, an automated computational framework for universal MIP development toward wearable applications. QuantumDock utilizes density functional theory to probe molecular interactions between monomers and the target/interferent molecules to optimize selectivity, a fundamentally limiting factor for MIP development toward wearable sensing. A molecular docking approach is employed to explore a wide range of known and unknown monomers, and to identify the optimal monomer/cross-linker choice for subsequent MIP fabrication. Using an essential amino acid phenylalanine as the exemplar, experimental validation of QuantumDock is performed successfully using solution-synthesized MIP nanoparticles coupled with ultraviolet-visible spectroscopy. Moreover, a QuantumDock-optimized graphene-based wearable device is designed that can perform autonomous sweat induction, sampling, and sensing. For the first time, wearable non-invasive phenylalanine monitoring is demonstrated in human subjects toward personalized healthcare applications.
Collapse
Affiliation(s)
- Daniel Mukasa
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
- These authors contributed equally to this work
| | - Minqiang Wang
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
- These authors contributed equally to this work
| | - Jihong Min
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
| | - Yiran Yang
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
| | - Samuel A. Solomon
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
| | - Hong Han
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
| | - Cui Ye
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology; Pasadena, California, 91125, USA
| |
Collapse
|