1
|
Ma J, Fei Y, Zhang J, Wu H. Wearable multiple sensing platform for enhanced biomolecules monitoring in food. Food Chem 2025; 469:142540. [PMID: 39721447 DOI: 10.1016/j.foodchem.2024.142540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2024] [Revised: 12/08/2024] [Accepted: 12/15/2024] [Indexed: 12/28/2024]
Abstract
Monitoring of biomolecules in food plays a crucial role in safeguarding human health. Prevalent biomolecule monitoring systems are constructed predominantly from rigid materials and have inherent limitations in detection capabilities. Wearable sensors have increasingly captured attention, significantly propelling the evolution of biomolecular detection process. However, most studies concentrate on the single sensing core that catalyze individual biomolecule, primarily for healthcare applications. This study introduces multiple biomolecules sensing platform based on a single-sensor core of hollow Prussian blue (h-PB), enabling efficient food detection. By utilizing varied potentials and leveraging excellent conductivity of MXene, this platform selectively and effectively tracks biomolecules including hydrogen peroxide, ascorbic acid, and glucose. Notably, the origin of electrochemical activity in this sensing system is demonstrated. This research provides a novel pathway for multi-sensing platforms design, leveraging a single catalytic core as active layer, thereby offering a promising trajectory for wearable electronics endowed with enhanced sensing capabilities.
Collapse
Affiliation(s)
- Junlin Ma
- College of Chemistry and Chemical Engineering, Engineering Research Center of Dairy Quality and Safety Control Technology, Ministry of Education, Inner Mongolia University, 235 University West Street, Hohhot, China.
| | - Yixiang Fei
- College of Chemistry and Chemical Engineering, Engineering Research Center of Dairy Quality and Safety Control Technology, Ministry of Education, Inner Mongolia University, 235 University West Street, Hohhot, China
| | - Jianxin Zhang
- School of Chemistry, Dalian University of Technology, Dalian, Liaoning 116024, China.
| | - Haixia Wu
- College of Chemistry and Chemical Engineering, Engineering Research Center of Dairy Quality and Safety Control Technology, Ministry of Education, Inner Mongolia University, 235 University West Street, Hohhot, China.
| |
Collapse
|
2
|
Rezki M, Hossain MM, Savage TK, Tokunou Y, Tsujimura S. Rational design of redox active metal organic frameworks for mediated electron transfer of enzymes. MATERIALS HORIZONS 2025; 12:760-769. [PMID: 39792379 DOI: 10.1039/d4mh01538j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2025]
Abstract
The efficient immobilization of redox mediators remains a major challenge in the design of mediated enzyme electrode platforms. In addition to stability, the ability of the redox-active material to mediate electron transfer from the active-site buried enzymes, such as flavin adenine dinucleotide-dependent glucose dehydrogenase (FADGDH) and lactate oxidase (LOx), is also crucial. Conventional immobilization techniques can be synthetically challenging, and immobilized mediators often exhibit limited durability, particularly in continuous operation. Here, we design a novel redox-active cobalt-based metal-organic framework (raMOF) obtained via the partial ligand substitution of 2-methylimidazole (MeIm) with a 1,2-naphthoquinone-4-sulfonate (NQSO) redox probe, as a promising platform for high-performance enzyme electrodes. This nanostructured raMOF, combined with multi-walled carbon nanotubes (CNTs), provided a high current density of up to 2.06 mA cm-2 during enzymatic reactions and maintained remarkable operational stability, retaining 100% of its current over 54 hours. This stability far exceeded that of adsorbed NQSO on CNTs, which experienced a complete loss of the initial current, highlighting the significant advantage of the raMOF-based platform for high-performance enzyme electrodes.
Collapse
Affiliation(s)
- Muhammad Rezki
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1, Tennodai, Ibaraki 305-5358, Japan
| | - Md Motaher Hossain
- Graduate School of Pure and Applied Sciences, University of Tsukuba, 1-1-1, Tennodai, Ibaraki 305-5358, Japan
| | - Thomas Kouyou Savage
- Degree Programs in Life and Earth Sciences, University of Tsukuba, 1-1-1, Tennodai, Ibaraki 305-8577, Japan
| | - Yoshihide Tokunou
- Department of Life and Environmental Sciences, University of Tsukuba, 1-1-1, Tennodai, Ibaraki 305-8577, Japan
- Research Center for Macromolecules and Biomaterials, National Institute for Materials Science, 1-1, Namiki, Ibaraki 305-0044, Japan
| | - Seiya Tsujimura
- Department of Material Sciences, Institute of Pure and Applied Sciences, University of Tsukuba, 1-1-1, Tennodai, Ibaraki 305-5358, Japan.
| |
Collapse
|
3
|
Brasier N, Wang J, Gao W, Sempionatto JR, Dincer C, Ates HC, Güder F, Olenik S, Schauwecker I, Schaffarczyk D, Vayena E, Ritz N, Weisser M, Mtenga S, Ghaffari R, Rogers JA, Goldhahn J. Applied body-fluid analysis by wearable devices. Nature 2024; 636:57-68. [PMID: 39633192 PMCID: PMC12007731 DOI: 10.1038/s41586-024-08249-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/18/2024] [Indexed: 12/07/2024]
Abstract
Wearable sensors are a recent paradigm in healthcare, enabling continuous, decentralized, and non- or minimally invasive monitoring of health and disease. Continuous measurements yield information-rich time series of physiological data that are holistic and clinically meaningful. Although most wearable sensors were initially restricted to biophysical measurements, the next generation of wearable devices is now emerging that enable biochemical monitoring of both small and large molecules in a variety of body fluids, such as sweat, breath, saliva, tears and interstitial fluid. Rapidly evolving data analysis and decision-making technologies through artificial intelligence has accelerated the application of wearables around the world. Although recent pilot trials have demonstrated the clinical applicability of these wearable devices, their widespread adoption will require large-scale validation across various conditions, ethical consideration and sociocultural acceptance. Successful translation of wearable devices from laboratory prototypes into clinical tools will further require a comprehensive transitional environment involving all stakeholders. The wearable device platforms must gain acceptance among different user groups, add clinical value for various medical indications, be eligible for reimbursements and contribute to public health initiatives. In this Perspective, we review state-of-the-art wearable devices for body-fluid analysis and their translation into clinical applications, and provide insight into their clinical purpose.
Collapse
Affiliation(s)
- Noé Brasier
- Collegium Helveticum, Zurich, Switzerland.
- Institute of Translational Medicine, ETH Zurich, Zurich, Switzerland.
| | - Joseph Wang
- Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, CA, USA
| | - Wei Gao
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Juliane R Sempionatto
- Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
| | - Can Dincer
- FIT Freiburg Center for Interactive Materials and Bioinspired Technologies, University of Freiburg, Freiburg, Germany
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
- Munich Institute of Biomedical Engineering - MIBE, Department of Electrical Engineering, TUM School of Computation, Information and Technology, Technical University of Munich, Munich, Germany
| | - H Ceren Ates
- FIT Freiburg Center for Interactive Materials and Bioinspired Technologies, University of Freiburg, Freiburg, Germany
- Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg, Germany
| | - Firat Güder
- Department of Bioengineering, Imperial College London, London, UK
| | - Selin Olenik
- Department of Bioengineering, Imperial College London, London, UK
| | - Ivo Schauwecker
- European Patients Academy on Therapeutic Innovation (EUPATI CH), Zurich, Switzerland
- Digital Trial Innovation Platform (dtip), ETH Zurich, Zurich, Switzerland
| | | | - Effy Vayena
- Health Ethics and Policy Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - Nicole Ritz
- University Children's Hospital Basel UKBB, Basel, Switzerland
- Paediatric Infectious Diseases and Vaccinology, University Children's Hospital Basel, Basel, Switzerland
- Department of Paediatrics and Paediatric Infectious Diseases, Children's Hospital, Lucerne Cantonal Hospital, Lucerne, Switzerland
| | - Maja Weisser
- Department of Health Systems, Impact Evaluation and Policy, Ifakara Health Institute, Ifakara, Tanzania
- Swiss Tropical and Public Health Institute, Allschwil, Switzerland
- Division of Infectious Diseases and Hospital Epidemiology, University Hospital Basel, Basel, Switzerland
| | - Sally Mtenga
- Department of Health Systems, Impact Evaluation and Policy, Ifakara Health Institute, Ifakara, Tanzania
| | - Roozbeh Ghaffari
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- Epicore Biosystems Inc, Cambridge, MA, USA
| | - John A Rogers
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL, USA
- Department of Mechanical Engineering, Northwestern University, Evanston, IL, USA
- Department of Chemistry, Northwestern University, Evanston, IL, USA
- Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Evanston, IL, USA
| | - Jörg Goldhahn
- Institute of Translational Medicine, ETH Zurich, Zurich, Switzerland
- Digital Trial Innovation Platform (dtip), ETH Zurich, Zurich, Switzerland
| |
Collapse
|
4
|
Shichitani K, Nakajima K. Preliminary Study of a Capacitive Diaper Sensor System for Urine Absorption Estimation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039803 DOI: 10.1109/embc53108.2024.10782079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Disposable adult diapers are used in medical and nursing care for people with dementia or bedridden patients who are unable to go to the toilet by themselves because of incontinence. To determine if a diaper needs to be changed, the blanket must be turned up, clothing removed, and the diaper opened for inspection. Several studies and products detect urination in diapers. However, most of them are specialized for urination detection, and it is not easy to evaluate the urination time and voided volume. Thus, we are developing a capacitive diaper sensor system that allows nurses and caregivers to remotely monitor urinary information. Herein, we compared the evaluation results of the developed capacitive sensor in phantom experiments with those in demonstration experiments. The results show the ability to remotely assess urination time and urine absorption in the diaper.
Collapse
|
5
|
Zhang T, Zhu J, Xie M, Meng K, Yao G, Pan T, Gao M, Cheng H, Lin Y. Highly Sensitive Wearable Sensor Based on (001)-Orientated TiO 2 for Real-Time Electrochemical Detection of Dopamine, Tyrosine, and Paracetamol. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2312238. [PMID: 38319031 DOI: 10.1002/smll.202312238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 01/22/2024] [Indexed: 02/07/2024]
Abstract
The concentration of dopamine (DA) and tyrosine (Tyr) reflects the condition of patients with Parkinson's disease, whereas moderate paracetamol (PA) can help relieve their pain. Therefore, real-time measurements of these bioanalytes have important clinical implications for patients with Parkinson's disease. However, previous sensors suffer from either limited sensitivity or complex fabrication and integration processes. This work introduces a simple and cost-effective method to prepare high-quality, flexible titanium dioxide (TiO2) thin films with highly reactive (001)-facets. The as-fabricated TiO2 film supported by a carbon cloth electrode (i.e., TiO2-CC) allows excellent electrochemical specificity and sensitivity to DA (1.390 µA µM-1 cm-2), Tyr (0.126 µA µM-1 cm-2), and PA (0.0841 µA µM-1 cm-2). More importantly, accurate DA concentration in varied pH conditions can be obtained by decoupling them within a single differential pulse voltammetry measurement without additional sensing units. The TiO2-CC electrochemical sensor can be integrated into a smart diaper to detect the trace amount of DA or an integrated skin-interfaced patch with microfluidic sampling and wireless transmission units for real-time detection of the sweat Try and PA concentration. The wearable sensor based on TiO2-CC prepared by facile manufacturing methods holds great potential in the daily health monitoring and care of patients with neurological disorders.
Collapse
Affiliation(s)
- Tianyao Zhang
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Jia Zhu
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
- Yangtze Delta Region Institute (Quzhou), University of Electronic Science and Technology of China, Quzhou, 324000, China
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA
| | - Maowen Xie
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Ke Meng
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Guang Yao
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Taisong Pan
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Min Gao
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
| | - Huanyu Cheng
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania, 16802, USA
| | - Yuan Lin
- School of Material and Energy, University of Electronic Science and Technology of China, Chengdu, 610054, China
- Medico-Engineering Cooperation on Applied Medicine Research Center, University of Electronics Science and Technology of China, Chengdu, 610054, China
| |
Collapse
|
6
|
Luo X, Tan H, Wen W. Recent Advances in Wearable Healthcare Devices: From Material to Application. Bioengineering (Basel) 2024; 11:358. [PMID: 38671780 PMCID: PMC11048539 DOI: 10.3390/bioengineering11040358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 04/02/2024] [Accepted: 04/04/2024] [Indexed: 04/28/2024] Open
Abstract
In recent years, the proliferation of wearable healthcare devices has marked a revolutionary shift in the personal health monitoring and management paradigm. These devices, ranging from fitness trackers to advanced biosensors, have not only made healthcare more accessible, but have also transformed the way individuals engage with their health data. By continuously monitoring health signs, from physical-based to biochemical-based such as heart rate and blood glucose levels, wearable technology offers insights into human health, enabling a proactive rather than a reactive approach to healthcare. This shift towards personalized health monitoring empowers individuals with the knowledge and tools to make informed decisions about their lifestyle and medical care, potentially leading to the earlier detection of health issues and more tailored treatment plans. This review presents the fabrication methods of flexible wearable healthcare devices and their applications in medical care. The potential challenges and future prospectives are also discussed.
Collapse
Affiliation(s)
- Xiao Luo
- Department of Physics, The Hong Kong University of Science and Technology, Hong Kong 999077, China;
- HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute (SHCIRI), Futian, Shenzhen 518060, China
| | - Handong Tan
- Department of Individualized Interdisciplinary Program (Advanced Materials), The Hong Kong University of Science and Technology, Hong Kong 999077, China;
| | - Weijia Wen
- Department of Physics, The Hong Kong University of Science and Technology, Hong Kong 999077, China;
- HKUST Shenzhen-Hong Kong Collaborative Innovation Research Institute (SHCIRI), Futian, Shenzhen 518060, China
| |
Collapse
|
7
|
Li H, Tan P, Rao Y, Bhattacharya S, Wang Z, Kim S, Gangopadhyay S, Shi H, Jankovic M, Huh H, Li Z, Maharjan P, Wells J, Jeong H, Jia Y, Lu N. E-Tattoos: Toward Functional but Imperceptible Interfacing with Human Skin. Chem Rev 2024; 124:3220-3283. [PMID: 38465831 DOI: 10.1021/acs.chemrev.3c00626] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/12/2024]
Abstract
The human body continuously emits physiological and psychological information from head to toe. Wearable electronics capable of noninvasively and accurately digitizing this information without compromising user comfort or mobility have the potential to revolutionize telemedicine, mobile health, and both human-machine or human-metaverse interactions. However, state-of-the-art wearable electronics face limitations regarding wearability and functionality due to the mechanical incompatibility between conventional rigid, planar electronics and soft, curvy human skin surfaces. E-Tattoos, a unique type of wearable electronics, are defined by their ultrathin and skin-soft characteristics, which enable noninvasive and comfortable lamination on human skin surfaces without causing obstruction or even mechanical perception. This review article offers an exhaustive exploration of e-tattoos, accounting for their materials, structures, manufacturing processes, properties, functionalities, applications, and remaining challenges. We begin by summarizing the properties of human skin and their effects on signal transmission across the e-tattoo-skin interface. Following this is a discussion of the materials, structural designs, manufacturing, and skin attachment processes of e-tattoos. We classify e-tattoo functionalities into electrical, mechanical, optical, thermal, and chemical sensing, as well as wound healing and other treatments. After discussing energy harvesting and storage capabilities, we outline strategies for the system integration of wireless e-tattoos. In the end, we offer personal perspectives on the remaining challenges and future opportunities in the field.
Collapse
Affiliation(s)
- Hongbian Li
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Philip Tan
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Yifan Rao
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Sarnab Bhattacharya
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Zheliang Wang
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Sangjun Kim
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Susmita Gangopadhyay
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Hongyang Shi
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Matija Jankovic
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Heeyong Huh
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Zhengjie Li
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Pukar Maharjan
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Jonathan Wells
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Hyoyoung Jeong
- Department of Electrical and Computer Engineering, University of California Davis, Davis, California 95616, United States
| | - Yaoyao Jia
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Nanshu Lu
- Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712, United States
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
- Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
8
|
Thangavel B, Venkatachalam G, Shin JH. Emerging Trends of Bilirubin Oxidases at the Bioelectrochemical Interface: Paving the Way for Self-Powered Electrochemical Devices and Biosensors. ACS APPLIED BIO MATERIALS 2024; 7:1381-1399. [PMID: 38437181 DOI: 10.1021/acsabm.3c01215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
Bilirubin oxidases (BODs) [EC 1.3.3.5 - bilirubin: oxygen oxido-reductase] are enzymes that belong to the multicopper oxidase family and can oxidize bilirubin, diphenols, and aryl amines and reduce the oxygen by direct four-electron transfer from the electrode with almost no electrochemical overpotential. Therefore, BOD is a promising bioelectrocatalyst for (self-powered) biosensors and/or enzymatic fuel cells. The advantages of electrochemically active BOD enzymes include selective biosensing, biocatalysis for efficient energy conversion, and electrosynthesis. Owing to the rise in publications and patents, as well as the expanding interest in BODs for a range of physiological conditions, this Review analyzes scientific literature reports on BOD enzymes and current hypotheses on their bioelectrocatalysis. This Review evaluates the specific research outcomes of the BOD in enzyme (protein) engineering, immobilization strategies, and challenges along with their bioelectrochemical properties, limitations, and applications in the fields of (i) biosensors, (ii) self-powered biosensors, and (iii) biofuel cells for powering bioelectronics.
Collapse
Affiliation(s)
- Balamurugan Thangavel
- Department of Biomedical Engineering, Pukyong National University, Busan 48513, Republic of Korea
| | - Ganesh Venkatachalam
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute, Karaikudi, Tamil Nadu 630003, India
- Academy of Scientific and Innovative Research, Ghaziabad 201002, India
| | - Joong Ho Shin
- Department of Biomedical Engineering, Pukyong National University, Busan 48513, Republic of Korea
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Republic of Korea
| |
Collapse
|
9
|
Takeshita M, Saito K, Suzuki Y, Yoshimasa W, Hayashi R, Chiba Y. Measurement of luteinizing hormone surge in vaginal discharge: a potential biomarker that enables simple, non-invasive prediction of the periovulatory period. BMC Womens Health 2024; 24:132. [PMID: 38378533 PMCID: PMC10877818 DOI: 10.1186/s12905-024-02916-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 01/19/2024] [Indexed: 02/22/2024] Open
Abstract
BACKGROUND Predicting the periovulatory period is very important for conception. Current approaches to predicting the periovulatory period include monitoring of basal body temperature and urine luteinizing hormone (LH) concentration; however, these methods are time-consuming. Here, we examined the potential of using vaginal discharge (VD) as a non-invasive means of sample collection for determining the LH surge that indicates ovulation. METHODS Urine and VD samples were collected from 35 healthy women aged 20-39 years. VD samples were collected with panty liners to reduce the burden on participants. Daily first urine samples and used panty liners were collected from the 10th through 19th days of the menstrual cycle. Urine and VD LH (uLH and vLH) levels in the samples were measured by enzyme-linked immunosorbent assay. Measured vLH baseline and first surge values were analyzed using Student's t-test and ROC curves. RESULTS Samples for a total of 55 menstrual cycles were collected. We used uLH surge to establish the date of ovulation. uLH surges were observed in 49 cycles, 34 of which had corresponding VD samples that qualified for measurement. Five cycles were excluded due to a lack of vLH data. In the remaining 29 cycles, the vLH surge appeared within the fertile window 90% of the time, and the sensitivity and specificity of the test were 86% and 83%, respectively. CONCLUSIONS VD has potential for use as a sample for predicting the periovulatory period by measuring LH content.
Collapse
Affiliation(s)
- Moto Takeshita
- Cranebio Co., Ltd, 2-13-4 Sotokanda, Chiyoda-Ku, Tokyo, 101-0021, Japan
- Cellspect Co., Ltd, 2-4-23, Kitaiioka, Morioka City, Iwate, 020-0857, Japan
| | - Keita Saito
- Cranebio Co., Ltd, 2-13-4 Sotokanda, Chiyoda-Ku, Tokyo, 101-0021, Japan
- Cellspect Co., Ltd, 2-4-23, Kitaiioka, Morioka City, Iwate, 020-0857, Japan
| | - Yuya Suzuki
- Unicharm Co., Ltd, 3-5-19, Mita, Minato-ku, Tokyo, 108-8575, Japan
- Unicharm Co., Ltd, 1531-7, Wadahama Toyohama-cho, kanonji-shi, Kagawa, 769-1602, Japan
| | - Wataru Yoshimasa
- Unicharm Co., Ltd, 1531-7, Wadahama Toyohama-cho, kanonji-shi, Kagawa, 769-1602, Japan
| | - Risako Hayashi
- Department of Nursing, Kyoto College of Nursing, 1-21 Mibuhigashitakada-cho, Nakagyo-ku, Kyoto, 604-8845, Japan
| | - Yoko Chiba
- Department of Nursing, Kyoto College of Nursing, 1-21 Mibuhigashitakada-cho, Nakagyo-ku, Kyoto, 604-8845, Japan.
- Department of Midwifery, Graduate School of Human Nursing, The University of Shiga Prefecture, 2500 Hassaka-cho, Hikone City, Shiga, 522-8533, Japan.
| |
Collapse
|
10
|
Xiao J, Chen Y, Xu T, Zhang X. Hand-held Raman spectrometer-based flexible plasmonic biosensor for label-free multiplex urinalysis. Talanta 2024; 266:124966. [PMID: 37499361 DOI: 10.1016/j.talanta.2023.124966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 07/04/2023] [Accepted: 07/18/2023] [Indexed: 07/29/2023]
Abstract
Urinalysis is an effective strategy to non-invasively evaluate human health, and surface-enhanced Raman scattering (SERS) may be a powerful technique for use in detecting analytes in urine. Herein, we report a wearable diaper sensor based on a handheld Raman spectrometer for use in the simple, label-free identification of biomolecules (urea, creatinine, and bilirubin) in urine. The raspberry-shaped Au substrate formed on the surface of an Si wafer provides plasmonic enhancement of the SERS signals, with an excellent uniformity and stability. The SERS sensor combines the advantages of flexibility, portability, and multifunctional detection and may be used in identifying multiple analytes in urine. The sensor exhibits high sensitivities in detecting urea, creatinine, and bilirubin, with respective detection limits of 4.17 × 10-3 M, 5.90 × 10-6 M, and 1.38 × 10-7 M (signal-to-noise ratio = 3). Furthermore, we used the wearable diaper sensor to monitor biomolecules at the diagnostic threshold, facilitating non-invasive diagnosis and medical monitoring of disease-related biomarkers.
Collapse
Affiliation(s)
- Jingyu Xiao
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, 518060, China
| | - Yanxia Chen
- Beijing Key Laboratory for Sensor, Beijing Information Science and Technology University, Beijing, 100101, China
| | - Tailin Xu
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, 518060, China.
| | - Xueji Zhang
- Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, 518060, China.
| |
Collapse
|
11
|
Garland NT, Kaveti R, Bandodkar AJ. Biofluid-Activated Biofuel Cells, Batteries, and Supercapacitors: A Comprehensive Review. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2303197. [PMID: 37358398 DOI: 10.1002/adma.202303197] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/06/2023] [Indexed: 06/27/2023]
Abstract
Recent developments in wearable and implanted devices have resulted in numerous, unprecedented capabilities that generate increasingly detailed information about a user's health or provide targeted therapy. However, options for powering such systems remain limited to conventional batteries which are large and have toxic components and as such are not suitable for close integration with the human body. This work provides an in-depth overview of biofluid-activated electrochemical energy devices, an emerging class of energy sources judiciously designed for biomedical applications. These unconventional energy devices are composed of biocompatible materials that harness the inherent chemistries of various biofluids to produce useable electrical energy. This work covers examples of such biofluid-activated energy devices in the form of biofuel cells, batteries, and supercapacitors. Advances in materials, design engineering, and biotechnology that form the basis for high-performance, biofluid-activated energy devices are discussed. Innovations in hybrid manufacturing and heterogeneous integration of device components to maximize power output are also included. Finally, key challenges and future scopes of this nascent field are provided.
Collapse
Affiliation(s)
- Nate T Garland
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| | - Rajaram Kaveti
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| | - Amay J Bandodkar
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| |
Collapse
|
12
|
Shitanda I, Oshimoto T, Loew N, Motosuke M, Watanabe H, Mikawa T, Itagaki M. Biosensor development for low-level acetaldehyde gas detection using mesoporous carbon electrode printed on a porous polyimide film. Biosens Bioelectron 2023; 238:115555. [PMID: 37542977 DOI: 10.1016/j.bios.2023.115555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 07/23/2023] [Accepted: 07/25/2023] [Indexed: 08/07/2023]
Abstract
Acetaldehyde, which is an intermediate product of alcohol metabolism, is known to induce symptoms, including alcohol flushing, vomiting, and headaches in humans. Therefore, real-time monitoring of acetaldehyde levels is crucial to mitigating these health issues. However, current methods for detecting low-concentration gases necessitate the use of complex measurement equipment. In this study, we developed a low-cost, low-detection-limit, enzyme-based electrochemical biosensor for acetaldehyde gas detection that does not require sophisticated equipment. The sensor was constructed by screen-printing electrodes onto a porous polyimide film, using grafted MgO-templated carbon (GMgOC) as working electrode material, carbon for the counter electrode, and silver/silver chloride for the reference electrode. Pyrroloquinoline-quinone-dependent aldehyde dehydrogenase was immobilized on the working electrode, and a chamber was attached to the electrode chip and filled with 1-methoxy-5-methylphenazinium methyl sulfate solution. The sensor can be used to measure acetaldehyde gas concentrations from 0.02 to 0.1 ppm, making it suitable for monitoring human skin gas. This low detection limit was achieved by delivering the analyte through the porous polyimide film on which the electrodes were printed and accumulating acetaldehyde in the mesoporous GMgOC of the working electrode. This mechanism suggests that this sensor design can be adapted to develop other low-detection limit gas sensors, such as those for screening skin gas biomarkers.
Collapse
Affiliation(s)
- Isao Shitanda
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan; Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan.
| | - Taisei Oshimoto
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| | - Noya Loew
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| | - Masahiro Motosuke
- Department of Mechanical Engineering, Faculty of Engineering, Tokyo University of Science, 3-1, Shinjuku 6-chome, Katsushika-ku, Tokyo, 125-8585, Japan
| | - Hikari Watanabe
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| | - Tsutomu Mikawa
- RIKEN Center for Biosystems Dynamics Research, 1-7-22 Suehiro-cho, Tsurumi-ku, Yokohama, Kanagawa, 230-0045, Japan
| | - Masayuki Itagaki
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan; Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| |
Collapse
|
13
|
Chi L, Zhang C, Wu X, Qian X, Sun H, He M, Guo C. Research Progress on Biomimetic Nanomaterials for Electrochemical Glucose Sensors. Biomimetics (Basel) 2023; 8:biomimetics8020167. [PMID: 37092419 PMCID: PMC10123724 DOI: 10.3390/biomimetics8020167] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 04/16/2023] [Accepted: 04/17/2023] [Indexed: 04/25/2023] Open
Abstract
Diabetes has become a chronic disease that necessitates timely and accurate detection. Among various detection methods, electrochemical glucose sensors have attracted much attention because of low cost, real-time detection, and simple and easy operation. Nonenzymatic biomimetic nanomaterials are the vital part in electrochemical glucose sensors. This review article summarizes the methods to enhance the glucose sensing performance of noble metal, transition metal oxides, and carbon-based materials and introduces biomimetic nanomaterials used in noninvasive glucose detection in sweat, tear, urine, and saliva. Based on these, this review provides the foundation for noninvasive determination of trace glucose for diabetic patients in the future.
Collapse
Affiliation(s)
- Lili Chi
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunmei Zhang
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xuanyu Wu
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
- School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xianghao Qian
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Hao Sun
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Mengru He
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunxian Guo
- School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| |
Collapse
|
14
|
Morshed J, Hossain MM, Zebda A, Tsujimura S. A disposable enzymatic biofuel cell for glucose sensing via short-circuit current. Biosens Bioelectron 2023; 230:115272. [PMID: 37023550 DOI: 10.1016/j.bios.2023.115272] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2023] [Revised: 03/16/2023] [Accepted: 03/27/2023] [Indexed: 04/01/2023]
Abstract
It is essential to construct a biofuel cell-based sensor and develop an effective strategy to detect glucose without any potentiostat circuitry in order to create a simple and miniaturized device. In this report, an enzymatic biofuel cell (EBFC) is fabricated by the facile design of an anode and cathode on a screen-printed carbon electrode (SPCE). To construct the anode, thionine and flavin adenine dinucleotide-dependent glucose dehydrogenase (FAD-GDH) are covalently immobilized via a crosslinker to make a cross-linked redox network. As a cathode, the Pt-free oxygen reduction carbon catalyst is employed alternative to the commonly used bilirubin oxidase. We proposed the importance of EBFC-based sensors through the connection of anode and cathode; they can identify a short-circuit current by means of applied zero external voltage, thereby capable of glucose detection without under the operation of the potentiostat. The result shows that the EBFC-based sensor could be able to detect based on a short-circuit current with a wide range of glucose concentrations from 0.28 to 30 mM. Further, an EBFC is employed as a one-compartment model energy harvester with a maximum power density of (36 ± 3) μW cm- 2 in sample volume 5 μL. In addition, the constructed EBFC-based sensor demonstrates that the physiological range of ascorbic acid and uric acid shows no significant effect on the short-circuit current generation. Moreover, this EBFC can be used as a sensor in artificial plasma without losing its performance and thereby used as a disposable test strip in real blood sample analysis.
Collapse
Affiliation(s)
- Jannatul Morshed
- Division of Material Science, Faculty of Pure and Applied Science, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-5358, Japan
| | - Motaher M Hossain
- Division of Material Science, Faculty of Pure and Applied Science, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-5358, Japan
| | - Abdelkader Zebda
- Université Grenoble Alpes, TIMC-IMAG/CNRS/INSERM, UMR 5525, F-38000, Grenoble, France
| | - Seiya Tsujimura
- Division of Material Science, Faculty of Pure and Applied Science, University of Tsukuba, 1-1-1, Tennodai, Tsukuba, Ibaraki, 305-5358, Japan.
| |
Collapse
|
15
|
Wang L, Zhu W, Zhang J, Zhu JJ. Miniaturized Microfluidic Electrochemical Biosensors Powered by Enzymatic Biofuel Cell. BIOSENSORS 2023; 13:175. [PMID: 36831941 PMCID: PMC9953942 DOI: 10.3390/bios13020175] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/09/2023] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
Electrochemical biosensors, in which enzymatic biofuel cells simultaneously work as energy power and signal generators, have become a research hotspot. They display the merits of power self-support, a simplified structure, in vivo operational feasibility, online and timely monitoring, etc. Since the concept of enzymatic biofuel cell-powered biosensors (EBFC-SPBs) was first proposed, its applications in health monitoring have scored tremendous achievements. However, the creation and practical application of portable EBFC-SPBs are still impeded by the difficulty in their miniaturization. In recent years, the booming microfluidic technology has powerfully pushed forward the progress made in miniaturized and portable EBFC-SPBs. This brief review recalls and summarizes the achievements and progress made in miniaturized EBFC-SPBs. In addition, we also discuss the advantages and challenges that microfluidic and screen-printing technologies provide to wearable and disposable EBFC-SPBs.
Collapse
Affiliation(s)
- Linlin Wang
- Shaanxi Key Laboratory of Chemical Additives for Industry, College of Chemistry and Chemical Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
- School of Chemistry and Chemical Engineering, School of Environment, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210023, China
| | - Wenlei Zhu
- School of Chemistry and Chemical Engineering, School of Environment, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210023, China
| | - Jianrong Zhang
- School of Chemistry and Chemical Engineering, School of Environment, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210023, China
| | - Jun-Jie Zhu
- School of Chemistry and Chemical Engineering, School of Environment, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing 210023, China
| |
Collapse
|
16
|
Shi Z, Li X, Shuai Y, Lu Y, Liu Q. The development of wearable technologies and their potential for measuring nutrient intake: Towards precision nutrition. NUTR BULL 2022; 47:388-406. [PMID: 36134894 DOI: 10.1111/nbu.12581] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 08/22/2022] [Accepted: 08/22/2022] [Indexed: 01/04/2023]
Abstract
Appropriate food intake and nutritional status are crucial for the maintenance of health and disease prevention. Conventional dietary assessment is mainly based on comparisons of nutrient intakes with reference intakes, failing to meet the needs of personalised nutritional guidance based on individual nutritional status. Given their capability of providing insights into health information non-invasively in real time, wearable technologies offer great opportunities for nutrition monitoring. Nutrient metabolic profiles can be monitored immediately and continuously which could potentially offer the possibility for the tracking and guiding of nutrient intake. Here, we review and highlight the recent advances in wearable sensors from the perspective of sensing technologies for nutrient detection in biofluids. The integration of biosensors with wearable devices serves as an ideal platform for the analysis of biofluids including sweat, saliva and tears. The wearable sensing systems applied to the analysis of typical nutrients and important metabolites are demonstrated in terms of carbohydrates, proteins, lipids, vitamins, minerals and others. Taking advantage of their high flexibility and lightweight, wearable sensors have been widely developed for the in situ quantitative detection of metabolic biomarkers. The technical principles, detection methods and applications are summarised. The challenges and future perspectives for wearable nutrition monitoring devices are discussed including the need to better determine relationships among nutrient metabolic profile, nutrient intake and food intake. With the development of materials, sensing techniques and manufacturing processes, wearable technologies are paving the way towards personalised precision nutrition, although there is still a long way to go before they can be utilised for practical clinical applications. Joint research efforts between nutrition scientists, doctors, engineers and sensor researchers are essential to further accelerate the realisation of reliable and practical wearable nutrition monitoring platforms.
Collapse
Affiliation(s)
- Zhenghan Shi
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, China
| | - Xin Li
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, China
| | - Yifan Shuai
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, China
| | - Yanli Lu
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, China
| | - Qingjun Liu
- Department of Biomedical Engineering, Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Zhejiang University, Hangzhou, China
| |
Collapse
|
17
|
Smart predictive analytics care monitoring model based on multi sensor IoT system: Management of diaper and attitude for the bedridden elderly. SENSORS INTERNATIONAL 2022. [DOI: 10.1016/j.sintl.2022.100213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
18
|
Loew N, Shitanda I, Goto H, Watanabe H, Mikawa T, Tsujimura S, Itagaki M. High-performance paper-based biocathode fabricated by screen-printing an improved mesoporous carbon ink and by oriented immobilization of bilirubin oxidase. Sci Rep 2022; 12:14649. [PMID: 36030337 PMCID: PMC9420125 DOI: 10.1038/s41598-022-19052-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 08/23/2022] [Indexed: 11/17/2022] Open
Abstract
In this study, the performance of a paper-based, screen-printed biofuel cell with mesoporous MgO-templated carbon (MgOC) electrodes was improved in two steps. First, a small amount of carboxymethyl cellulose (CMC) was added to the MgOC ink. Next, the cathode was modified with bilirubin prior to immobilizing the bilirubin oxidase (BOD). The CMC increased the accessibility of the mesopores of the MgOC, and subsequently, the performance of both the bioanode and biocathode. CMC also likely increased the stability of the electrodes. The pre-modification with bilirubin improved the orientation of the BOD, which facilitated direct electron transfer. With these two steps, an open circuit potential of 0.65 V, a maximal current density of 1.94 mA cm−2, and a maximal power density of 465 μW cm−2 was achieved with lactate oxidase as bioanode enzyme and lactate as fuel. This is one of the highest reported performances for a biofuel cell.
Collapse
Affiliation(s)
- Noya Loew
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| | - Isao Shitanda
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan. .,Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan.
| | - Himeka Goto
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| | - Hikari Watanabe
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| | - Tsutomu Mikawa
- RIKEN Center for Biosystems Dynamics Research, 1-7-22 Suehirocho, Tsurumiku, Yokohama, Kanagawa, 230-0045, Japan
| | - Seiya Tsujimura
- Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan.,Division of Materials Sciences, Faculty of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8573, Japan
| | - Masayuki Itagaki
- Department of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan.,Research Institute for Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba, 278-8510, Japan
| |
Collapse
|
19
|
Ates HC, Nguyen PQ, Gonzalez-Macia L, Morales-Narváez E, Güder F, Collins JJ, Dincer C. End-to-end design of wearable sensors. NATURE REVIEWS. MATERIALS 2022; 7:887-907. [PMID: 35910814 PMCID: PMC9306444 DOI: 10.1038/s41578-022-00460-x] [Citation(s) in RCA: 324] [Impact Index Per Article: 108.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 06/15/2022] [Indexed: 05/03/2023]
Abstract
Wearable devices provide an alternative pathway to clinical diagnostics by exploiting various physical, chemical and biological sensors to mine physiological (biophysical and/or biochemical) information in real time (preferably, continuously) and in a non-invasive or minimally invasive manner. These sensors can be worn in the form of glasses, jewellery, face masks, wristwatches, fitness bands, tattoo-like devices, bandages or other patches, and textiles. Wearables such as smartwatches have already proved their capability for the early detection and monitoring of the progression and treatment of various diseases, such as COVID-19 and Parkinson disease, through biophysical signals. Next-generation wearable sensors that enable the multimodal and/or multiplexed measurement of physical parameters and biochemical markers in real time and continuously could be a transformative technology for diagnostics, allowing for high-resolution and time-resolved historical recording of the health status of an individual. In this Review, we examine the building blocks of such wearable sensors, including the substrate materials, sensing mechanisms, power modules and decision-making units, by reflecting on the recent developments in the materials, engineering and data science of these components. Finally, we synthesize current trends in the field to provide predictions for the future trajectory of wearable sensors.
Collapse
Affiliation(s)
- H. Ceren Ates
- FIT Freiburg Center for Interactive Materials and Bioinspired Technology, University of Freiburg, Freiburg, Germany
- IMTEK – Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| | - Peter Q. Nguyen
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA USA
| | | | - Eden Morales-Narváez
- Biophotonic Nanosensors Laboratory, Centro de Investigaciones en Óptica, León, Mexico
| | - Firat Güder
- Department of Bioengineering, Imperial College London, London, UK
| | - James J. Collins
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA USA
- Institute of Medical Engineering & Science, Department of Biological Engineering, MIT, Cambridge, MA USA
- Broad Institute of MIT and Harvard, Cambridge, MA USA
| | - Can Dincer
- FIT Freiburg Center for Interactive Materials and Bioinspired Technology, University of Freiburg, Freiburg, Germany
- IMTEK – Department of Microsystems Engineering, University of Freiburg, Freiburg, Germany
| |
Collapse
|
20
|
Wu Y, Bakker E. Direct Energy Transfer from a pH Glass Electrode to a Liquid Crystal Display. Anal Chem 2022; 94:10408-10414. [PMID: 35818788 DOI: 10.1021/acs.analchem.2c01557] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Self-powered sensors are attractive because the lack of a dedicated battery makes them environmentally friendly and allows them to be more easily miniaturized. Unfortunately, the development of self-powered potentiometric sensors is challenging because only very limited energy can be harvested from this measurement principle. For the first time, the potential of a high impedance glass pH electrode (130 M Ω) is shown here to be directly read out optically. This is accomplished by a liquid crystal display (LCD) as the electrochromic transducer, which changes its transmission upon imposing an external voltage in the range of 2-3 V. Importantly, owing to its low capacitance of about 50 pF, this process requires a very small transient charge on the order of 100 pC, which may be spontaneously imposable even across pH glass electrodes. For the LCD to be turned on, the cell voltage is boosted by additional Zn2+/Zn elements placed in series. The LCD is found to give a time-dependent absorbance decrease, which is mitigated by adding a high resistance element to attenuate the associated decay. The approach gives repeatable LCD absorbance values that allows one to directly visualize pH with a precision of about 0.01 pH units. The absorbance value depends inversely on pH in a much wider range (pH 1-13) than what is normally observed with optical sensors while based on the same underlying measurement as a potentiometric pH probe.
Collapse
Affiliation(s)
- Yaotian Wu
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211, Geneva, Switzerland
| | - Eric Bakker
- Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, CH-1211, Geneva, Switzerland
| |
Collapse
|
21
|
Tiwari N, Chatterjee S, Kaswan K, Chung JH, Fan KP, Lin ZH. Recent advancements in sampling, power management strategies and development in applications for non-invasive wearable electrochemical sensors. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116064] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|