Michelon T, Schroeder R, Fagundes I, Canabarro R, Sporleder H, Rodrigues H, Silveira J, Montagner J, Garcia V, Neumann J, Graudenz M. Clinical Relevance of Low Levels of Preformed Alloantibodies Detected by Flow Cytometry in the First Year Post–Kidney Transplantation.
Transplant Proc 2005;
37:2750-2. [PMID:
16182800 DOI:
10.1016/j.transproceed.2005.05.040]
[Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE
To determine the prevalence of transplants performed with a false-negative cytotoxicity cross-match and to analyze the clinical relevance of alloantibodies (Ab) detected only by flow cytometry (flow).
METHODS
We studied 66 patients undergoing kidney transplantation from a cadaveric donor. All patients had a simultaneous negative T+AHG+DTT and B+DTT. Pretransplant sera were retrospectively analyzed by flow cytometry according to an Emory University protocol: (1) T+ and B-: Ab anti-class I; (2) T- and B+: anti-class II; (3) T+B+: anti-class I + II. Chi-square, Fisher exact, Student t test, and Kaplan Meier analyses were employed with significance assigned at P < or = .05.
RESULTS
The overall incidence of false-negative cytotoxicity was 33.3% (22/66), namely, 6.1% (n = 4) anti-class I; 9.1% (n = 6) anti-class II; and 18.2% (n = 12) anti-class I + II. Primary nonfunctioning grafts occurred in 6.8% (3/44) and 13.6% (3/22) negative and positive flow patients (two anti-class I + II and one class II; P = .39). The incidence of graft loss in the first year was respectively, 13.6% (6/44) and 18.2% (4/22; two anti-class II and two anti-class I + II; P = .72). Compared to flow-negative grafts, creatinine levels were significantly higher among flow-positive patients at 8 and 12 weeks. One-year graft survivals were 86.4% among negative versus 81.8% for the positive group (P = .67).
CONCLUSIONS
We observed that 33% of kidney transplant recipients had low levels of alloantibodies detected only by flow. This single factor was associated with the worst graft function in the first trimester with a suggestion of a higher risk for non-functioning graft.
Collapse