1
|
Nepomuceno P, Souza WH, Pakosh M, Musselman KE, Craven BC. Exoskeleton-based exercises for overground gait and balance rehabilitation in spinal cord injury: a systematic review of dose and dosage parameters. J Neuroeng Rehabil 2024; 21:73. [PMID: 38705999 PMCID: PMC11070073 DOI: 10.1186/s12984-024-01365-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 04/22/2024] [Indexed: 05/07/2024] Open
Abstract
BACKGROUND Exoskeletons are increasingly applied during overground gait and balance rehabilitation following neurological impairment, although optimal parameters for specific indications are yet to be established. OBJECTIVE This systematic review aimed to identify dose and dosage of exoskeleton-based therapy protocols for overground locomotor training in spinal cord injury/disease. METHODS A systematic review was conducted in accordance with the Preferred Reporting Items Systematic Reviews and Meta-Analyses guidelines. A literature search was performed using the CINAHL Complete, Embase, Emcare Nursing, Medline ALL, and Web of Science databases. Studies in adults with subacute and/or chronic spinal cord injury/disease were included if they reported (1) dose (e.g., single session duration and total number of sessions) and dosage (e.g., frequency of sessions/week and total duration of intervention) parameters, and (2) at least one gait and/or balance outcome measure. RESULTS Of 2,108 studies identified, after removing duplicates and filtering for inclusion, 19 were selected and dose, dosage and efficacy were abstracted. Data revealed a great heterogeneity in dose, dosage, and indications, with overall recommendation of 60-min sessions delivered 3 times a week, for 9 weeks in 27 sessions. Specific protocols were also identified for functional restoration (60-min, 3 times a week, for 8 weeks/24 sessions) and cardiorespiratory rehabilitation (60-min, 3 times a week, for 12 weeks/36 sessions). CONCLUSION This review provides evidence-based best practice recommendations for overground exoskeleton training among individuals with spinal cord injury/disease based on individual therapeutic goals - functional restoration or cardiorespiratory rehabilitation. There is a need for structured exoskeleton clinical translation studies based on standardized methods and common therapeutic outcomes.
Collapse
Affiliation(s)
- Patrik Nepomuceno
- KITE Research Institute, University Health Network, Toronto, ON, Canada
- Graduate Program in Health Promotion, Department of Health Sciences, University of Santa Cruz do Sul, Santa Cruz do Sul, RS, Brazil
- Institute of Health Policy Management and Evaluation, University of Toronto, Toronto, Canada
| | - Wagner H Souza
- KITE Research Institute, University Health Network, Toronto, ON, Canada
| | - Maureen Pakosh
- KITE Research Institute, University Health Network, Toronto, ON, Canada
| | - Kristin E Musselman
- KITE Research Institute, University Health Network, Toronto, ON, Canada
- Department of Physical Therapy, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
- Rehabilitation Sciences Institute, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada
| | - B Catharine Craven
- KITE Research Institute, University Health Network, Toronto, ON, Canada.
- Department of Medicine, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada.
- Institute of Health Policy Management and Evaluation, University of Toronto, Toronto, Canada.
- Rehabilitation Sciences Institute, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada.
| |
Collapse
|
2
|
van Nes IJ, van Dijsseldonk RB, van Herpen FH, Rijken H, Geurts AC, Keijsers NL. Improvement of quality of life after 2-month exoskeleton training in patients with chronic spinal cord injury. J Spinal Cord Med 2024; 47:354-360. [PMID: 35377297 PMCID: PMC11044750 DOI: 10.1080/10790268.2022.2052502] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
OBJECTIVE To examine changes in quality of life (QoL) after an eight-week period of robotic exoskeleton training in a homogeneous group of patients with chronic complete spinal cord injury (SCI). DESIGN Prospective single-group pre-post study. SETTING Rehabilitation center. PARTICIPANTS Patients with a chronic (>6 months) motor complete SCI (T1-L1). INTERVENTION Twenty-four training sessions with the ReWalk exoskeleton over an eight-week period. MAIN OUTCOME MEASURE QoL, assessed with the sum score of the Short Form-36 with Walk Wheel modification (SF-36ww). Secondary outcome measures were the eight SF-36ww subdomains, satisfaction with bladder and bowel management, lower extremity joint passive range of motion (pROM), and lower extremity spasticity. RESULTS Twenty-one participants completed the training. QoL significantly improved after the training period (average SF-36 sum score 621 ± 90) compared to baseline (571 ± 133) (t(20)=-2.5, P=.02). Improvements were seen on the SF-36ww subdomains for pain (P=.003), social functioning (P=.03), mental health (P=.02), and general health perception (P=.01). Satisfaction with bladder management (range 1-5) improved from median 3 at baseline to 4 after exoskeleton training (P=0.01). No changes in satisfaction with bowel management (P=.11), pROM (hip-extension (P=.49), knee-extension (P=.36), ankle dorsiflexion (P=.69)), or spasticity (P=.94) were found. CONCLUSION Even in patients with chronic motor complete SCI and a relatively high level of QoL at baseline, a short-term exoskeleton training improved their QoL, pain and satisfaction with bladder management; findings that warrant further controlled studies in this specific SCI population.
Collapse
Affiliation(s)
- Ilse J.W. van Nes
- Department of Rehabilitation, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Rosanne B. van Dijsseldonk
- Department of Research, Sint Maartenskliniek, Nijmegen, The Netherlands
- Department of Rehabilitation, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Frank H.M. van Herpen
- Department of Rehabilitation, Sint Maartenskliniek, Nijmegen, The Netherlands
- Department of Rehabilitation, Canisius Wilhelmina Hospital, Nijmegen, The Netherlands
| | - Hennie Rijken
- Department of Rehabilitation, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Alexander C.H. Geurts
- Department of Research, Sint Maartenskliniek, Nijmegen, The Netherlands
- Department of Rehabilitation, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Noël L.W. Keijsers
- Department of Research, Sint Maartenskliniek, Nijmegen, The Netherlands
- Department of Rehabilitation, Donders Institute for Brain, Cognition and Behavior, Radboud University Medical Center, Nijmegen, The Netherlands
| |
Collapse
|
3
|
Mahon J, Nolan L, O'Sullivan D, Curtin M, Devitt A, Murphy CG. Bilateral tibial fractures associated with powered exoskeleton use in complete spinal cord injury - a case report & literature review. Spinal Cord Ser Cases 2024; 10:22. [PMID: 38627367 PMCID: PMC11021521 DOI: 10.1038/s41394-024-00635-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 03/31/2024] [Accepted: 04/05/2024] [Indexed: 04/19/2024] Open
Abstract
INTRODUCTION Powered robotic exoskeleton (PRE) physiotherapy programmes are a relatively novel frontier which allow patients with reduced mobility to engage in supported walking. Research is ongoing regarding their utility, risks, and benefits. This article describes the case of two fractures occurring in one patient using a PRE. CASE We report the case of a 54 year old man who sustained bilateral tibial fractures while using a PRE, on a background of T10 AIS A SCI. The initial session was discontinued due to acute severe bilateral knee swelling after approximately 15 min. The patient attended their local hospital the following day, where radiographs demonstrated bilateral proximal tibial fractures. The patient was treated with manipulation under anaesthetic and long-leg casting for five weeks, at which point he was stepped down to hinged knee braces which were weaned gradually while he remained non-weight bearing for 12 weeks. The patient was investigated with DEXA scan and was diagnosed with osteoporosis. He was liaised with rheumatology services and bone protection was initiated. Fracture healing was achieved and weight-bearing precautions were discontinued, however this period of immobilisation led to significant spasticity. The patient was discharged from orthopaedic services, with ongoing rehabilitation and physiotherapy follow-up. CONCLUSION PRE assisted physiotherapy programmes are a promising concept in terms of rehabilitation and independence, however they are not without risk and it is important that both providers and patients are aware of this. Furthermore, SCI patients are at increased risk for osteoporosis and should be monitored and considered for bone protection.
Collapse
Affiliation(s)
- John Mahon
- University Hospital Galway, Newcastle Road, Galway, Ireland.
| | - Lily Nolan
- University Hospital Galway, Newcastle Road, Galway, Ireland
| | | | - Mark Curtin
- University Hospital Galway, Newcastle Road, Galway, Ireland
| | - Aiden Devitt
- University Hospital Galway, Newcastle Road, Galway, Ireland
| | - Colin G Murphy
- University Hospital Galway, Newcastle Road, Galway, Ireland
| |
Collapse
|
4
|
Tanaka T, Matsumura R, Miura T. Influence of Varied Load Assistance with Exoskeleton-Type Robotic Device on Gait Rehabilitation in Healthy Adult Men. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:9713. [PMID: 35955068 PMCID: PMC9368586 DOI: 10.3390/ijerph19159713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 08/04/2022] [Accepted: 08/05/2022] [Indexed: 06/15/2023]
Abstract
This study aimed to clarify how the power-assist function of the hybrid assistive limb (HAL®), an exoskeleton-type gait-assist device, affected the gait characteristics of patients who wear it, specifically focusing on the "misalignment" of the robot joints and landmarks with the corresponding body parts. Five healthy adult men were video-recorded wearing the HAL® as they walked normally on a treadmill under seven conditions corresponding to the strengths and sites of robotic power assistance. For kinematic analysis, reflective markers were attached to the HAL® and the wearer at key locations, and participants were recorded walking past a set of four video cameras for each condition. A motion analysis system was used for analysis. The walking motion was segmented into eight-phase gait cycles. Knee misalignment, or the relative offset in position of the HAL®/wearer knee joints, was calculated from kinematic data and joint angles. These values were compared with respect to two factors: assist level and gait phase. Statistical analysis consisted of parametric and nonparametric tests for comparing the values of misalignment of each gait phase, followed by multiple comparisons to confirm significant differences. The results showed that the knee misalignment was greatest in the pre-swing phase and was significantly lower overall in conditions with high levels of power assistance. The result of greater knee misalignment in the pre-swing phase may be attributed to the structural properties of the HAL® lower-limb exoskeleton. This provides valuable insight regarding the walking stages that should be given special attention during the evaluation of synchrony between exoskeleton-type gait-assist robots and their wearers.
Collapse
Affiliation(s)
- Toshiaki Tanaka
- The Research Center for Advanced Science and Technology, Institute of Gerontology, The University of Tokyo, Tokyo 113-8656, Japan
- Department of Physical Therapy, Faculty of Health Sciences, Hokkaido University of Science, Sapporo 006-8585, Japan
| | - Ryo Matsumura
- Department of Physical Therapy, Faculty of Health Sciences, Hokkaido University of Science, Sapporo 006-8585, Japan
| | - Takahiro Miura
- National Institute of Advanced Industrial Science and Technology (AIST), Kashiwa 277-0882, Japan
| |
Collapse
|
5
|
Tamburella F, Lorusso M, Tramontano M, Fadlun S, Masciullo M, Scivoletto G. Overground robotic training effects on walking and secondary health conditions in individuals with spinal cord injury: systematic review. J Neuroeng Rehabil 2022; 19:27. [PMID: 35292044 PMCID: PMC8922901 DOI: 10.1186/s12984-022-01003-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 02/14/2022] [Indexed: 12/12/2022] Open
Abstract
Overground powered lower limb exoskeletons (EXOs) have proven to be valid devices in gait rehabilitation in individuals with spinal cord injury (SCI). Although several articles have reported the effects of EXOs in these individuals, the few reviews available focused on specific domains, mainly walking. The aim of this systematic review is to provide a general overview of the effects of commercial EXOs (i.e. not EXOs used in military and industry applications) for medical purposes in individuals with SCI. This systematic review was conducted following the PRISMA guidelines and it referred to MED-LINE, EMBASE, SCOPUS, Web of Science and Cochrane library databases. The studies included were Randomized Clinical Trials (RCTs) and non-RCT based on EXOs intervention on individuals with SCI. Out of 1296 studies screened, 41 met inclusion criteria. Among all the EXO studies, the Ekso device was the most discussed, followed by ReWalk, Indego, HAL and Rex devices. Since 14 different domains were considered, the outcome measures were heterogeneous. The most investigated domain was walking, followed by cardiorespiratory/metabolic responses, spasticity, balance, quality of life, human–robot interaction, robot data, bowel functionality, strength, daily living activity, neurophysiology, sensory function, bladder functionality and body composition/bone density domains. There were no reports of negative effects due to EXOs trainings and most of the significant positive effects were noted in the walking domain for Ekso, ReWalk, HAL and Indego devices. Ekso studies reported significant effects due to training in almost all domains, while this was not the case with the Rex device. Not a single study carried out on sensory functions or bladder functionality reached significance for any EXO. It is not possible to draw general conclusions about the effects of EXOs usage due to the lack of high-quality studies as addressed by the Downs and Black tool, the heterogeneity of the outcome measures, of the protocols and of the SCI epidemiological/neurological features. However, the strengths and weaknesses of EXOs are starting to be defined, even considering the different types of adverse events that EXO training brought about. EXO training showed to bring significant improvements over time, but whether its effectiveness is greater or less than conventional therapy or other treatments is still mostly unknown. High-quality RCTs are necessary to better define the pros and cons of the EXOs available today. Studies of this kind could help clinicians to better choose the appropriate training for individuals with SCI.
Collapse
Affiliation(s)
- Federica Tamburella
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy.
| | - Matteo Lorusso
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Marco Tramontano
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Silvia Fadlun
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Marcella Masciullo
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| | - Giorgio Scivoletto
- I.R.C.C.S. Santa Lucia Foundation (FSL), Via Ardeatina, 306, 00179, Rome, Italy
| |
Collapse
|
6
|
Preliminary training volume and progression algorithm to tackle fragility fracture risk during exoskeleton-assisted overground walking in individuals with a chronic spinal cord injury. Spinal Cord Ser Cases 2022; 8:29. [PMID: 35260550 PMCID: PMC8904785 DOI: 10.1038/s41394-022-00498-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 02/17/2022] [Accepted: 02/20/2022] [Indexed: 11/08/2022] Open
|
7
|
Bessler-Etten J, Schaake L, Prange-Lasonder GB, Buurke JH. Assessing effects of exoskeleton misalignment on knee joint load during swing using an instrumented leg simulator. J Neuroeng Rehabil 2022; 19:13. [PMID: 35090501 PMCID: PMC8800279 DOI: 10.1186/s12984-022-00990-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 01/14/2022] [Indexed: 12/04/2022] Open
Abstract
Background Exoskeletons are working in parallel to the human body and can support human movement by exerting forces through cuffs or straps. They are prone to misalignments caused by simplified joint mechanics and incorrect fit or positioning. Those misalignments are a common safety concern as they can cause undesired interaction forces. However, the exact mechanisms and effects of misalignments on the joint load are not yet known. The aim of this study was therefore to investigate the influence of different directions and magnitudes of exoskeleton misalignment on the internal knee joint forces and torques of an artificial leg.
Methods An instrumented leg simulator was used to quantify the changes in knee joint load during the swing phase caused by misalignments of a passive knee brace being manually flexed. This was achieved by an experimenter pulling on a rope attached to the distal end of the knee brace to create a flexion torque. The extension was not actuated but achieved through the weight of the instrumented leg simulator. The investigated types of misalignments are a rotation of the brace around the vertical axis and a translation in anteroposterior as well as proximal/distal direction. Results The amount of misalignment had a significant effect on several directions of knee joint load in the instrumented leg simulator. In general, load on the knee joint increased with increasing misalignment. Specifically, stronger rotational misalignment led to higher forces in mediolateral direction in the knee joint as well as higher ab-/adduction, flexion and internal/external rotation torques. Stronger anteroposterior translational misalignment led to higher mediolateral knee forces as well as higher abduction and flexion/extension torques. Stronger proximal/distal translational misalignment led to higher posterior and tension/compression forces. Conclusions Misalignments of a lower leg exoskeleton can increase internal knee forces and torques during swing to a multiple of those experienced in a well-aligned situation. Despite only taking swing into account, this is supporting the need for carefully considering hazards associated with not only translational but also rotational misalignments during wearable robot development and use. Also, this warrants investigation of misalignment effects in stance, as a target of many exoskeleton applications.
Collapse
|
8
|
Postol N, Spratt NJ, Bivard A, Marquez J. Physiotherapy using a free-standing robotic exoskeleton for patients with spinal cord injury: a feasibility study. J Neuroeng Rehabil 2021; 18:180. [PMID: 34953501 PMCID: PMC8709973 DOI: 10.1186/s12984-021-00967-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Accepted: 11/30/2021] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND Evidence is emerging for the use of overground lower limb robotic exoskeletons in the rehabilitation of people with spinal cord injury (SCI), with suggested benefits for gait speed, bladder and bowel function, pain management and spasticity. To date, research has focused on devices that require the user to support themselves with a walking aid. This often precludes use by those with severe trunk, postural or upper limb deficits and places the user in a suboptimal, flexed standing position. Free-standing exoskeletons enable people with higher level injuries to exercise in an upright position. This study aimed to evaluate the feasibility of therapy with a free-standing exoskeleton for those with SCI, and to determine the potential health-related benefits of this intervention. METHODS This 12-week intervention study with 12-week waitlist control and 12-week follow up, provided people with SCI scoring < 5 on the mobility section of the spinal cord independence measure (SCIM-III) twice weekly therapy in the REX (Rex Bionics, Auckland, NZ), a free-standing lower limb robotic exoskeleton. The primary outcome measure of interest was function, as measured on the SCIM-III. A battery of secondary outcomes was included. Participants also completed a survey on their perceptions of this treatment modality, to determine acceptability. RESULTS Forty-one potential participants were screened for eligibility. Two females (one ASIA A, one ASIA C) and one male (ASIA B) completed all 24 intervention sessions, and the follow up assessment. One participant showed positive trends in function, fatigue, quality of life and mood during the intervention phase. Grip and quadriceps strength, and lower limb motor function improved in another. Two improved their percentage of lean body mass during the intervention phase. Remaining results were varied across patients, time points and outcomes. The intervention was highly acceptable to all participants. CONCLUSION With three of 41 potential participants being eligible and completing this study, our results show that there are potential benefits of exercise in a free-standing exoskeleton for people with severe mobility impairment due to SCI, for a small subset of patients. Further research is warranted to determine those most likely to benefit, and the type of benefit depending on the patient characteristics. Trial registration The trial was registered prospectively on 20 April 2018 at www.anzctr.org.au/ (ACTRN12618000626268).
Collapse
Affiliation(s)
- Nicola Postol
- University of Newcastle, Callaghan, Australia.
- Hunter Medical Research Institute, New Lambton Heights, Australia.
| | - Neil J Spratt
- University of Newcastle, Callaghan, Australia
- Hunter Medical Research Institute, New Lambton Heights, Australia
- Hunter New England Local Health District, New South Wales, Australia
| | - Andrew Bivard
- Hunter Medical Research Institute, New Lambton Heights, Australia
- University of Melbourne, Melbourne, Australia
| | - Jodie Marquez
- University of Newcastle, Callaghan, Australia
- Hunter Medical Research Institute, New Lambton Heights, Australia
| |
Collapse
|
9
|
Bessler J, Prange-Lasonder GB, Schaake L, Saenz JF, Bidard C, Fassi I, Valori M, Lassen AB, Buurke JH. Safety Assessment of Rehabilitation Robots: A Review Identifying Safety Skills and Current Knowledge Gaps. Front Robot AI 2021; 8:602878. [PMID: 33937345 PMCID: PMC8080797 DOI: 10.3389/frobt.2021.602878] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 01/28/2021] [Indexed: 11/19/2022] Open
Abstract
The assessment of rehabilitation robot safety is a vital aspect of the development process, which is often experienced as difficult. There are gaps in best practices and knowledge to ensure safe usage of rehabilitation robots. Currently, safety is commonly assessed by monitoring adverse events occurrence. The aim of this article is to explore how safety of rehabilitation robots can be assessed early in the development phase, before they are used with patients. We are suggesting a uniform approach for safety validation of robots closely interacting with humans, based on safety skills and validation protocols. Safety skills are an abstract representation of the ability of a robot to reduce a specific risk or deal with a specific hazard. They can be implemented in various ways, depending on the application requirements, which enables the use of a single safety skill across a wide range of applications and domains. Safety validation protocols have been developed that correspond to these skills and consider domain-specific conditions. This gives robot users and developers concise testing procedures to prove the mechanical safety of their robotic system, even when the applications are in domains with a lack of standards and best practices such as the healthcare domain. Based on knowledge about adverse events occurring in rehabilitation robot use, we identified multi-directional excessive forces on the soft tissue level and musculoskeletal level as most relevant hazards for rehabilitation robots and related them to four safety skills, providing a concrete starting point for safety assessment of rehabilitation robots. We further identified a number of gaps which need to be addressed in the future to pave the way for more comprehensive guidelines for rehabilitation robot safety assessments. Predominantly, besides new developments of safety by design features, there is a strong need for reliable measurement methods as well as acceptable limit values for human-robot interaction forces both on skin and joint level.
Collapse
Affiliation(s)
- Jule Bessler
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands
| | - Gerdienke B Prange-Lasonder
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| | | | - José F Saenz
- Fraunhofer Institute for Factory Operation and Automation, Magdeburg, Germany
| | | | - Irene Fassi
- National Research Council of Italy, Milan, Italy
| | | | - Aske Bach Lassen
- Department of Robot Technology, Danish Technological Institute, Odense, Denmark
| | - Jaap H Buurke
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands
| |
Collapse
|
10
|
Rodríguez-Fernández A, Lobo-Prat J, Font-Llagunes JM. Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments. J Neuroeng Rehabil 2021; 18:22. [PMID: 33526065 PMCID: PMC7852187 DOI: 10.1186/s12984-021-00815-5] [Citation(s) in RCA: 100] [Impact Index Per Article: 33.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 01/12/2021] [Indexed: 02/08/2023] Open
Abstract
Gait disorders can reduce the quality of life for people with neuromuscular impairments. Therefore, walking recovery is one of the main priorities for counteracting sedentary lifestyle, reducing secondary health conditions and restoring legged mobility. At present, wearable powered lower-limb exoskeletons are emerging as a revolutionary technology for robotic gait rehabilitation. This systematic review provides a comprehensive overview on wearable lower-limb exoskeletons for people with neuromuscular impairments, addressing the following three questions: (1) what is the current technological status of wearable lower-limb exoskeletons for gait rehabilitation?, (2) what is the methodology used in the clinical validations of wearable lower-limb exoskeletons?, and (3) what are the benefits and current evidence on clinical efficacy of wearable lower-limb exoskeletons? We analyzed 87 clinical studies focusing on both device technology (e.g., actuators, sensors, structure) and clinical aspects (e.g., training protocol, outcome measures, patient impairments), and make available the database with all the compiled information. The results of the literature survey reveal that wearable exoskeletons have potential for a number of applications including early rehabilitation, promoting physical exercise, and carrying out daily living activities both at home and the community. Likewise, wearable exoskeletons may improve mobility and independence in non-ambulatory people, and may reduce secondary health conditions related to sedentariness, with all the advantages that this entails. However, the use of this technology is still limited by heavy and bulky devices, which require supervision and the use of walking aids. In addition, evidence supporting their benefits is still limited to short-intervention trials with few participants and diversity among their clinical protocols. Wearable lower-limb exoskeletons for gait rehabilitation are still in their early stages of development and randomized control trials are needed to demonstrate their clinical efficacy.
Collapse
Affiliation(s)
- Antonio Rodríguez-Fernández
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain. .,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.
| | - Joan Lobo-Prat
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain.,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.,ABLE Human Motion, Diagonal 647, 08028, Barcelona, Spain.,Institut de Robòtica i Informàtica Industrial, CSIC-UPC, Llorens i Artigas 4-6, 08028, Barcelona, Spain
| | - Josep M Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain.,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.,ABLE Human Motion, Diagonal 647, 08028, Barcelona, Spain
| |
Collapse
|
11
|
Bessler J, Prange-Lasonder GB, Schulte RV, Schaake L, Prinsen EC, Buurke JH. Occurrence and Type of Adverse Events During the Use of Stationary Gait Robots-A Systematic Literature Review. Front Robot AI 2020; 7:557606. [PMID: 33501319 PMCID: PMC7805916 DOI: 10.3389/frobt.2020.557606] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 10/05/2020] [Indexed: 12/29/2022] Open
Abstract
Robot-assisted gait training (RAGT) devices are used in rehabilitation to improve patients' walking function. While there are some reports on the adverse events (AEs) and associated risks in overground exoskeletons, the risks of stationary gait trainers cannot be accurately assessed. We therefore aimed to collect information on AEs occurring during the use of stationary gait robots and identify associated risks, as well as gaps and needs, for safe use of these devices. We searched both bibliographic and full-text literature databases for peer-reviewed articles describing the outcomes of stationary RAGT and specifically mentioning AEs. We then compiled information on the occurrence and types of AEs and on the quality of AE reporting. Based on this, we analyzed the risks of RAGT in stationary gait robots. We included 50 studies involving 985 subjects and found reports of AEs in 18 of those studies. Many of the AE reports were incomplete or did not include sufficient detail on different aspects, such as severity or patient characteristics, which hinders the precise counts of AE-related information. Over 169 device-related AEs experienced by between 79 and 124 patients were reported. Soft tissue-related AEs occurred most frequently and were mostly reported in end-effector-type devices. Musculoskeletal AEs had the second highest prevalence and occurred mainly in exoskeleton-type devices. We further identified physiological AEs including blood pressure changes that occurred in both exoskeleton-type and end-effector-type devices. Training in stationary gait robots can cause injuries or discomfort to the skin, underlying tissue, and musculoskeletal system, as well as unwanted blood pressure changes. The underlying risks for the most prevalent injury types include excessive pressure and shear at the interface between robot and human (cuffs/harness), as well as increased moments and forces applied to the musculoskeletal system likely caused by misalignments (between joint axes of robot and human). There is a need for more structured and complete recording and dissemination of AEs related to robotic gait training to increase knowledge on risks. With this information, appropriate mitigation strategies can and should be developed and implemented in RAGT devices to increase their safety.
Collapse
Affiliation(s)
- Jule Bessler
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands
| | - Gerdienke B Prange-Lasonder
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| | - Robert V Schulte
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands
| | | | - Erik C Prinsen
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| | - Jaap H Buurke
- Roessingh Research and Development, Enschede, Netherlands.,Department of Biomedical Signals and Systems, University of Twente, Enschede, Netherlands
| |
Collapse
|