1
|
Hudson SM, Wilkinson LS, De Stavola BL, dos-Santos-Silva I. Are mammography image acquisition factors, compression pressure and paddle tilt, associated with breast cancer detection in screening? Br J Radiol 2023; 96:20230085. [PMID: 37660396 PMCID: PMC10546457 DOI: 10.1259/bjr.20230085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Revised: 04/19/2023] [Accepted: 04/28/2023] [Indexed: 09/05/2023] Open
Abstract
OBJECTIVES To assess the associations between objectively measured mammographic compression pressure and paddle tilt and breast cancer (BC) detected at the same ("contemporaneous") screen, subsequent screens, or in-between screens (interval cancers). METHODS Automated pressure and paddle tilt estimates were derived for 80,495 mammographic examinations in a UK population-based screening programme. Adjusted logistic regression models were fitted to estimate the associations of compression parameters with BC detected at contemporaneous screen (777 cases).Nested case-control designs were used to estimate associations of pressure and tilt with: (a) interval cancer (148 cases/625 age-matched controls) and (b) subsequent screen-detected cancer (344/1436), via conditional logistic regression. RESULTS Compression pressure was negatively associated with odds of BC at contemporaneous screen (odds ratio (OR) for top versus bottom third of the pressure distribution: 0.74; 95% CI 0.60, 0.92; P-for-linear-trend (Pt) = 0.007). There was weak evidence that moderate pressure at screening was associated with lower odds of interval cancer (OR for middle versus bottom third: 0.63; 95% CI 0.38, 1.05; p = 0.079), but no association was found between pressure and the odds of BC at subsequent screen. There was no evidence that paddle tilt was associated with the odds of contemporaneous, subsequent screen or interval cancer detection. CONCLUSIONS Findings are consistent with compression pressure, but not paddle tilt, affecting the performance of mammographic screening by interfering with its ability to detect cancers. ADVANCES IN KNOWLEDGE Inadequate or excessive compression pressure at screening may contribute to a reduced ability to detect cancers, resulting in a greater number of interval cancer cases.
Collapse
Affiliation(s)
- Sue M Hudson
- Department of Non-Communicable Disease Epidemiology, London School of Hygiene and Tropical Medicine, London, United Kingdom
| | - Louise S Wilkinson
- Oxford Breast Imaging Centre, Churchill Hospital,Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Bianca L De Stavola
- Faculty of Pop Health Sciences, Institute of Child Health, University College London, London, United Kingdom
| | - Isabel dos-Santos-Silva
- Department of Non-Communicable Disease Epidemiology, London School of Hygiene and Tropical Medicine, London, United Kingdom
| |
Collapse
|
3
|
Henze Bancroft LC, Strigel RM, Macdonald EB, Longhurst C, Johnson J, Hernando D, Reeder SB. Proton density water fraction as a reproducible MR-based measurement of breast density. Magn Reson Med 2021; 87:1742-1757. [PMID: 34775638 DOI: 10.1002/mrm.29076] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 10/06/2021] [Accepted: 10/19/2021] [Indexed: 01/12/2023]
Abstract
PURPOSE To introduce proton density water fraction (PDWF) as a confounder-corrected (CC) MR-based biomarker of mammographic breast density, a known risk factor for breast cancer. METHODS Chemical shift encoded (CSE) MR images were acquired using a low flip angle to provide proton density contrast from multiple echo times. Fat and water images, corrected for known biases, were produced by a six-echo CC CSE-MRI algorithm. Fibroglandular tissue (FGT) volume was calculated from whole-breast segmented PDWF maps at 1.5T and 3T. The method was evaluated in (1) a physical fat-water phantom and (2) normal volunteers. Results from two- and three-echo CSE-MRI methods were included for comparison. RESULTS Six-echo CC-CSE-MRI produced unbiased estimates of the total water volume in the phantom (mean bias 3.3%) and was reproducible across protocol changes (repeatability coefficient [RC] = 14.8 cm3 and 13.97 cm3 at 1.5T and 3.0T, respectively) and field strengths (RC = 51.7 cm3 ) in volunteers, while the two- and three-echo CSE-MRI approaches produced biased results in phantoms (mean bias 30.7% and 10.4%) that was less reproducible across field strengths in volunteers (RC = 82.3 cm3 and 126.3 cm3 ). Significant differences in measured FGT volume were found between the six-echo CC-CSE-MRI and the two- and three-echo CSE-MRI approaches (p = 0.002 and p = 0.001, respectively). CONCLUSION The use of six-echo CC-CSE-MRI to create unbiased PDWF maps that reproducibly quantify FGT in the breast is demonstrated. Further studies are needed to correlate this quantitative MR biomarker for breast density with mammography and overall risk for breast cancer.
Collapse
Affiliation(s)
| | - Roberta M Strigel
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,University of Wisconsin Carbone Cancer Center, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Erin B Macdonald
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Clinical Imaging Physics Group, Duke University Medical Center, Durham, North Carolina, USA
| | - Colin Longhurst
- Department of Biostatistics and Medical Informatics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Jacob Johnson
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Diego Hernando
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Scott B Reeder
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Department of Emergency Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
4
|
Bredno J, Lipson J, Venn O, Aravanis AM, Jamshidi A. Clinical correlates of circulating cell-free DNA tumor fraction. PLoS One 2021; 16:e0256436. [PMID: 34432811 PMCID: PMC8386888 DOI: 10.1371/journal.pone.0256436] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 08/08/2021] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Oncology applications of cell-free DNA analysis are often limited by the amount of circulating tumor DNA and the fraction of cell-free DNA derived from tumor cells in a blood sample. This circulating tumor fraction varies widely between individuals and cancer types. Clinical factors that influence tumor fraction have not been completely elucidated. METHODS AND FINDINGS Circulating tumor fraction was determined for breast, lung, and colorectal cancer participant samples in the first substudy of the Circulating Cell-free Genome Atlas study (CCGA; NCT02889978; multi-cancer early detection test development) and was related to tumor and patient characteristics. Linear models were created to determine the influence of tumor size combined with mitotic or metabolic activity (as tumor mitotic volume or excessive lesion glycolysis, respectively), histologic type, histologic grade, and lymph node status on tumor fraction. For breast and lung cancer, tumor mitotic volume and excessive lesion glycolysis (primary lesion volume scaled by percentage positive for Ki-67 or PET standardized uptake value minus 1.0, respectively) were the only statistically significant covariates. For colorectal cancer, the surface area of tumors invading beyond the subserosa was the only significant covariate. The models were validated with cases from the second CCGA substudy and show that these clinical correlates of circulating tumor fraction can predict and explain the performance of a multi-cancer early detection test. CONCLUSIONS Prognostic clinical variables, including mitotic or metabolic activity and depth of invasion, were identified as correlates of circulating tumor DNA by linear models that relate clinical covariates to tumor fraction. The identified correlates indicate that faster growing tumors have higher tumor fractions. Early cancer detection from assays that analyze cell-free DNA is determined by circulating tumor fraction. Results support that early detection is particularly sensitive for faster growing, aggressive tumors with high mortality, many of which have no available screening today.
Collapse
Affiliation(s)
- Joerg Bredno
- GRAIL, Inc., Menlo Park, California, United States of America
| | - Jafi Lipson
- GRAIL, Inc., Menlo Park, California, United States of America
| | - Oliver Venn
- GRAIL, Inc., Menlo Park, California, United States of America
| | | | - Arash Jamshidi
- GRAIL, Inc., Menlo Park, California, United States of America
| |
Collapse
|