Shen X, Özen AC, Monsivais H, Susnjar A, Ilbey S, Zheng W, Du Y, Chiew M, Emir U. High-resolution 3D ultra-short echo time MRI with Rosette k-space pattern for brain iron content mapping. J Trace Elem Med Biol 2023; 77:127146. [PMID: 36871432 PMCID: PMC10107748 DOI: 10.1016/j.jtemb.2023.127146] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 01/10/2023] [Accepted: 01/31/2023] [Indexed: 03/05/2023]
Abstract
BACKGROUND The iron concentration increases during normal brain development and is identified as a risk factor for many neurodegenerative diseases, it is vital to monitor iron content in the brain non-invasively. PURPOSE This study aimed to quantify in vivo brain iron concentration with a 3D rosette-based ultra-short echo time (UTE) magnetic resonance imaging (MRI) sequence. METHODS A cylindrical phantom containing nine vials of different iron concentrations (iron (II) chloride) from 0.5 millimoles to 50 millimoles and six healthy subjects were scanned using 3D high-resolution (0.94 ×0.94 ×0.94 mm3) rosette UTE sequence at an echo time (TE) of 20 μs. RESULTS Iron-related hyperintense signals (i.e., positive contrast) were detected based on the phantom scan, and were used to establish an association between iron concentration and signal intensity. The signal intensities from in vivo scans were then converted to iron concentrations based on the association. The deep brain structures, such as the substantia nigra, putamen, and globus pallidus, were highlighted after the conversion, which indicated potential iron accumulations. CONCLUSION This study suggested that T1-weighted signal intensity could be used for brain iron mapping.
Collapse
Affiliation(s)
- Xin Shen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Ali Caglar Özen
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | - Antonia Susnjar
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Serhat Ilbey
- Department of Radiology, Medical Physics, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Wei Zheng
- School of Health Sciences, Purdue University, West Lafayette, IN, USA
| | - Yansheng Du
- Department of Neurology, School of Medicine, Indiana University, Bloomington, IN, USA
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, UK
| | - Uzay Emir
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; School of Health Sciences, Purdue University, West Lafayette, IN, USA.
| |
Collapse
|
2
|
Lombardi AF, Guma M, Chung CB, Chang EY, Du J, Ma YJ. Ultrashort echo time magnetic resonance imaging of the osteochondral junction. NMR IN BIOMEDICINE 2023; 36:e4843. [PMID: 36264245 PMCID: PMC9845195 DOI: 10.1002/nbm.4843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 09/20/2022] [Accepted: 10/10/2022] [Indexed: 06/16/2023]
Abstract
Osteoarthritis is a common chronic degenerative disease that causes pain and disability with increasing incidence worldwide. The osteochondral junction is a dynamic region of the joint that is associated with the early development and progression of osteoarthritis. Despite the substantial advances achieved in the imaging of cartilage and application to osteoarthritis in recent years, the osteochondral junction has received limited attention. This is primarily related to technical limitations encountered with conventional MR sequences that are relatively insensitive to short T2 tissues and the rapid signal decay that characterizes these tissues. MR sequences with ultrashort echo time (UTE) are of great interest because they can provide images of high resolution and contrast in this region. Here, we briefly review the anatomy and function of cartilage, focusing on the osteochondral junction. We also review basic concepts and recent applications of UTE MR sequences focusing on the osteochondral junction.
Collapse
Affiliation(s)
- Alecio F. Lombardi
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Monica Guma
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
- Department of Medicine, University of California San Diego, CA, United States
| | - Christine B. Chung
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Eric Y. Chang
- Department of Radiology, University of California San Diego, CA, United States
- Research Service, Veterans Affairs San Diego Healthcare System, CA, United States
| | - Jiang Du
- Department of Radiology, University of California San Diego, CA, United States
| | - Ya-Jun Ma
- Department of Radiology, University of California San Diego, CA, United States
| |
Collapse
|
3
|
Ma Y, Jang H, Jerban S, Chang EY, Chung CB, Bydder GM, Du J. Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications. APPLIED PHYSICS REVIEWS 2022; 9:041303. [PMID: 36467869 PMCID: PMC9677812 DOI: 10.1063/5.0086459] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 09/12/2022] [Indexed: 05/25/2023]
Abstract
Magnetic resonance imaging (MRI) uses a large magnetic field and radio waves to generate images of tissues in the body. Conventional MRI techniques have been developed to image and quantify tissues and fluids with long transverse relaxation times (T2s), such as muscle, cartilage, liver, white matter, gray matter, spinal cord, and cerebrospinal fluid. However, the body also contains many tissues and tissue components such as the osteochondral junction, menisci, ligaments, tendons, bone, lung parenchyma, and myelin, which have short or ultrashort T2s. After radio frequency excitation, their transverse magnetizations typically decay to zero or near zero before the receiving mode is enabled for spatial encoding with conventional MR imaging. As a result, these tissues appear dark, and their MR properties are inaccessible. However, when ultrashort echo times (UTEs) are used, signals can be detected from these tissues before they decay to zero. This review summarizes recent technical developments in UTE MRI of tissues with short and ultrashort T2 relaxation times. A series of UTE MRI techniques for high-resolution morphological and quantitative imaging of these short-T2 tissues are discussed. Applications of UTE imaging in the musculoskeletal, nervous, respiratory, gastrointestinal, and cardiovascular systems of the body are included.
Collapse
Affiliation(s)
- Yajun Ma
- Department of Radiology, University of California, San Diego, California 92037, USA
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, California 92037, USA
| | - Saeed Jerban
- Department of Radiology, University of California, San Diego, California 92037, USA
| | | | | | - Graeme M Bydder
- Department of Radiology, University of California, San Diego, California 92037, USA
| | - Jiang Du
- Author to whom correspondence should be addressed:. Tel.: (858) 246-2248, Fax: (858) 246-2221
| |
Collapse
|
4
|
Xiang X, Shi D, Gao J. The Advances and Biomedical Applications of Imageable Nanomaterials. Front Bioeng Biotechnol 2022; 10:914105. [PMID: 35866027 PMCID: PMC9294271 DOI: 10.3389/fbioe.2022.914105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/06/2022] [Indexed: 11/13/2022] Open
Abstract
Nanomedicine shows great potential in screening, diagnosing and treating diseases. However, given the limitations of current technology, detection of some smaller lesions and drugs’ dynamic monitoring still need to be improved. With the advancement of nanotechnology, researchers have produced various nanomaterials with imaging capabilities which have shown great potential in biomedical research. Here, we summarized the researches based on the characteristics of imageable nanomaterials, highlighted the advantages and biomedical applications of imageable nanomaterials in the diagnosis and treatment of diseases, and discussed current challenges and prospects.
Collapse
Affiliation(s)
- Xiaohong Xiang
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Doudou Shi
- Department of Gastroenterology, The Affiliated Hospital of Yan’an University, Yan’an, China
| | - Jianbo Gao
- Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
- *Correspondence: Jianbo Gao,
| |
Collapse
|
5
|
Friedrich RP, Cicha I, Alexiou C. Iron Oxide Nanoparticles in Regenerative Medicine and Tissue Engineering. NANOMATERIALS 2021; 11:nano11092337. [PMID: 34578651 PMCID: PMC8466586 DOI: 10.3390/nano11092337] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 09/03/2021] [Accepted: 09/06/2021] [Indexed: 12/13/2022]
Abstract
In recent years, many promising nanotechnological approaches to biomedical research have been developed in order to increase implementation of regenerative medicine and tissue engineering in clinical practice. In the meantime, the use of nanomaterials for the regeneration of diseased or injured tissues is considered advantageous in most areas of medicine. In particular, for the treatment of cardiovascular, osteochondral and neurological defects, but also for the recovery of functions of other organs such as kidney, liver, pancreas, bladder, urethra and for wound healing, nanomaterials are increasingly being developed that serve as scaffolds, mimic the extracellular matrix and promote adhesion or differentiation of cells. This review focuses on the latest developments in regenerative medicine, in which iron oxide nanoparticles (IONPs) play a crucial role for tissue engineering and cell therapy. IONPs are not only enabling the use of non-invasive observation methods to monitor the therapy, but can also accelerate and enhance regeneration, either thanks to their inherent magnetic properties or by functionalization with bioactive or therapeutic compounds, such as drugs, enzymes and growth factors. In addition, the presence of magnetic fields can direct IONP-labeled cells specifically to the site of action or induce cell differentiation into a specific cell type through mechanotransduction.
Collapse
|
6
|
Zhang B, Tian X, Qu Z, Liu J, Yang L, Zhang W. Efficacy of extracellular vesicles from mesenchymal stem cells on osteoarthritis in animal models: a systematic review and meta-analysis. Nanomedicine (Lond) 2021; 16:1297-1310. [PMID: 34044578 DOI: 10.2217/nnm-2021-0047] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Background: Some studies have reported results from the use of mesenchymal stem cell-derived extracellular vesicles (MSC-EVs) to treat osteoarthritis (OA). Objective: To evaluate the efficacy of MSC-EVs as a treatment for OA. Data sources: Databases were searched using the terms 'mesenchymal stem cells', 'osteoarthritis' and 'extracellular vesicles.' Study eligibility criteria: Studies performed in animal models utilizing MSC-EVs to treat OA that described the macroscopic evaluation or histological evaluation were included. Study appraisal: The quality of the studies was examined using the CAMARADES quality checklist. Results: MSC-EVs were superior to the placebo in the macroscopic evaluation and histological evaluation. MSC-EVs were more effective in the early stage of OA and once a week was better than multiple times a week. Limitations: The included studies were highly heterogeneous. Conclusion: MSC-EVs may improve the results of macroscopic and histological evaluations of OA.
Collapse
Affiliation(s)
- Bocheng Zhang
- Department of Orthopaedics, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, 116000, China.,Graduate School, Dalian Medical University, Dalian, Liaoning, 116000, China
| | - Xiaoyuan Tian
- Second Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, 116000, China.,Graduate School, Dalian Medical University, Dalian, Liaoning, 116000, China
| | - Zhenan Qu
- Orthopedics IV, Affiliated Zhongshan Hospital of Dalian University, Liaoning, 116000, China
| | - Jiaming Liu
- Graduate School, Dalian Medical University, Dalian, Liaoning, 116000, China
| | - Liang Yang
- Second Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, 116000, China
| | - Weiguo Zhang
- Department of Orthopaedics, First Affiliated Hospital, Dalian Medical University, Dalian, Liaoning, 116000, China.,Graduate School, Dalian Medical University, Dalian, Liaoning, 116000, China
| |
Collapse
|
7
|
Pawelec KM, Chakravarty S, Hix JML, Perry KL, van Holsbeeck L, Fajardo R, Shapiro EM. Design Considerations to Facilitate Clinical Radiological Evaluation of Implantable Biomedical Structures. ACS Biomater Sci Eng 2021; 7:718-726. [PMID: 33449622 PMCID: PMC8670580 DOI: 10.1021/acsbiomaterials.0c01439] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Clinical effectiveness of implantable medical devices would be improved with in situ monitoring to ensure device positioning, determine subsequent damage, measure biodegradation, and follow healing. While standard clinical imaging protocols are appropriate for diagnosing disease and injury, these protocols have not been vetted for imaging devices. This study investigated how radiologists use clinical imaging to detect the location and integrity of implanted devices and whether embedding nanoparticle contrast agents into devices can improve assessment. To mimic the variety of devices available, phantoms from hydrophobic polymer films and hydrophilic gels were constructed, with and without computed tomography (CT)-visible TaOx and magnetic resonance imaging (MRI)-visible Fe3O4 nanoparticles. Some phantoms were purposely damaged by nick or transection. Phantoms were implanted in vitro into tissue and imaged with clinical CT, MRI, and ultrasound. In a blinded study, radiologists independently evaluated whether phantoms were present, assessed the type, and diagnosed whether phantoms were damaged or intact. Radiologists identified the location of phantoms 80% of the time. However, without incorporated nanoparticles, radiologists correctly assessed damage in only 54% of cases. With an incorporated imaging agent, the percentage jumped to 86%. The imaging technique which was most useful to radiologists varied with the properties of phantoms. With benefits and drawbacks to all three imaging modalities, future implanted devices should be engineered for visibility in the modality which best fits the treated tissue, the implanted device's physical location, and the type of required information. Imaging protocols should also be tailored to best exploit the properties of the imaging agents.
Collapse
Affiliation(s)
- Kendell M Pawelec
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Shatadru Chakravarty
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Jeremy M L Hix
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Karen L Perry
- College of Veterinary Medicine, Michigan State University, East Lansing, Michigan 48824, United States
| | - Lodewijk van Holsbeeck
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Ryan Fajardo
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| | - Erik M Shapiro
- Department of Radiology, Michigan State University, East Lansing, Michigan 48824, United States
| |
Collapse
|