1
|
Xie J, Wang Z, Yu Z, Ding Y, Guo B. Prototype Learning for Medical Time Series Classification via Human-Machine Collaboration. SENSORS (BASEL, SWITZERLAND) 2024; 24:2655. [PMID: 38676273 PMCID: PMC11054195 DOI: 10.3390/s24082655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 04/15/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024]
Abstract
Deep neural networks must address the dual challenge of delivering high-accuracy predictions and providing user-friendly explanations. While deep models are widely used in the field of time series modeling, deciphering the core principles that govern the models' outputs remains a significant challenge. This is crucial for fostering the development of trusted models and facilitating domain expert validation, thereby empowering users and domain experts to utilize them confidently in high-risk decision-making contexts (e.g., decision-support systems in healthcare). In this work, we put forward a deep prototype learning model that supports interpretable and manipulable modeling and classification of medical time series (i.e., ECG signal). Specifically, we first optimize the representation of single heartbeat data by employing a bidirectional long short-term memory and attention mechanism, and then construct prototypes during the training phase. The final classification outcomes (i.e., normal sinus rhythm, atrial fibrillation, and other rhythm) are determined by comparing the input with the obtained prototypes. Moreover, the proposed model presents a human-machine collaboration mechanism, allowing domain experts to refine the prototypes by integrating their expertise to further enhance the model's performance (contrary to the human-in-the-loop paradigm, where humans primarily act as supervisors or correctors, intervening when required, our approach focuses on a human-machine collaboration, wherein both parties engage as partners, enabling more fluid and integrated interactions). The experimental outcomes presented herein delineate that, within the realm of binary classification tasks-specifically distinguishing between normal sinus rhythm and atrial fibrillation-our proposed model, albeit registering marginally lower performance in comparison to certain established baseline models such as Convolutional Neural Networks (CNNs) and bidirectional long short-term memory with attention mechanisms (Bi-LSTMAttns), evidently surpasses other contemporary state-of-the-art prototype baseline models. Moreover, it demonstrates significantly enhanced performance relative to these prototype baseline models in the context of triple classification tasks, which encompass normal sinus rhythm, atrial fibrillation, and other rhythm classifications. The proposed model manifests a commendable prediction accuracy of 0.8414, coupled with macro precision, recall, and F1-score metrics of 0.8449, 0.8224, and 0.8235, respectively, achieving both high classification accuracy as well as good interpretability.
Collapse
Affiliation(s)
| | - Zhu Wang
- School of Computer Science, Northwestern Polytechnical University, Xi’an 710072, China; (J.X.); (Z.Y.); (Y.D.); (B.G.)
| | | | | | | |
Collapse
|
2
|
Abrego L, Zaikin A, Marino IP, Krivonosov MI, Jacobs I, Menon U, Gentry‐Maharaj A, Blyuss O. Bayesian and deep-learning models applied to the early detection of ovarian cancer using multiple longitudinal biomarkers. Cancer Med 2024; 13:e7163. [PMID: 38597129 PMCID: PMC11004913 DOI: 10.1002/cam4.7163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 03/16/2024] [Accepted: 03/26/2024] [Indexed: 04/11/2024] Open
Abstract
BACKGROUND Ovarian cancer is the most lethal of all gynecological cancers. Cancer Antigen 125 (CA125) is the best-performing ovarian cancer biomarker which however is still not effective as a screening test in the general population. Recent literature reports additional biomarkers with the potential to improve on CA125 for early detection when using longitudinal multimarker models. METHODS Our data comprised 180 controls and 44 cases with serum samples sourced from the multimodal arm of UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS). Our models were based on Bayesian change-point detection and recurrent neural networks. RESULTS We obtained a significantly higher performance for CA125-HE4 model using both methodologies (AUC 0.971, sensitivity 96.7% and AUC 0.987, sensitivity 96.7%) with respect to CA125 (AUC 0.949, sensitivity 90.8% and AUC 0.953, sensitivity 92.1%) for Bayesian change-point model (BCP) and recurrent neural networks (RNN) approaches, respectively. One year before diagnosis, the CA125-HE4 model also ranked as the best, whereas at 2 years before diagnosis no multimarker model outperformed CA125. CONCLUSIONS Our study identified and tested different combination of biomarkers using longitudinal multivariable models that outperformed CA125 alone. We showed the potential of multivariable models and candidate biomarkers to increase the detection rate of ovarian cancer.
Collapse
Affiliation(s)
- Luis Abrego
- Department of Women's CancerEGA Institute for Women's Health, University College LondonLondonUK
- Department of MathematicsUniversity College LondonLondonUK
| | - Alexey Zaikin
- Department of Women's CancerEGA Institute for Women's Health, University College LondonLondonUK
- Department of MathematicsUniversity College LondonLondonUK
| | - Ines P. Marino
- Department of Biology and Geology, Physics and Inorganic ChemistryUniversidad Rey Juan CarlosMadridSpain
| | - Mikhail I. Krivonosov
- Research Center for Trusted Artificial IntelligenceIvannikov Institute for System Programming of the Russian Academy of SciencesMoscowRussia
- Institute of BiogerontologyLobachevsky State UniversityNizhny NovgorodRussia
| | - Ian Jacobs
- Department of Women's CancerEGA Institute for Women's Health, University College LondonLondonUK
| | - Usha Menon
- MRC Clinical Trials UnitUniversity College LondonLondonUK
| | - Aleksandra Gentry‐Maharaj
- Department of Women's CancerEGA Institute for Women's Health, University College LondonLondonUK
- MRC Clinical Trials UnitUniversity College LondonLondonUK
| | - Oleg Blyuss
- Department of Women's CancerEGA Institute for Women's Health, University College LondonLondonUK
- Wolfson Institute of Population HealthQueen Mary University of LondonLondonUK
- Department of Pediatrics and Pediatric Infectious Diseases, Institute of Child's HealthSechenov First Moscow State Medical University (Sechenov University)MoscowRussia
| |
Collapse
|
3
|
Idrobo-Ávila E, Bognár G, Krefting D, Penzel T, Kovács P, Spicher N. Quantifying the Suitability of Biosignals Acquired During Surgery for Multimodal Analysis. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2024; 5:250-260. [PMID: 38766543 PMCID: PMC11100950 DOI: 10.1109/ojemb.2024.3379733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 01/22/2024] [Accepted: 03/12/2024] [Indexed: 05/22/2024] Open
Abstract
Goal: Recently, large datasets of biosignals acquired during surgery became available. As they offer multiple physiological signals measured in parallel, multimodal analysis - which involves their joint analysis - can be conducted and could provide deeper insights than unimodal analysis based on a single signal. However, it is unclear what percentage of intraoperatively acquired data is suitable for multimodal analysis. Due to the large amount of data, manual inspection and labelling into suitable and unsuitable segments are not feasible. Nevertheless, multimodal analysis is performed successfully in sleep studies since many years as their signals have proven suitable. Hence, this study evaluates the suitability to perform multimodal analysis on a surgery dataset (VitalDB) using a multi-center sleep dataset (SIESTA) as reference. Methods: We applied widely known algorithms entitled "signal quality indicators" to the common biosignals in both datasets, namely electrocardiography, electroencephalography, and respiratory signals split in segments of 10 s duration. As there are no multimodal methods available, we used only unimodal signal quality indicators. In case, all three signals were determined as being adequate by the indicators, we assumed that the whole signal segment was suitable for multimodal analysis. Results: 82% of SIESTA and 72% of VitalDB are suitable for multimodal analysis. Unsuitable signal segments exhibit constant or physiologically unreasonable values. Histogram examination indicated similar signal quality distributions between the datasets, albeit with potential statistical biases due to different measurement setups. Conclusions: The majority of data within VitalDB is suitable for multimodal analysis.
Collapse
Affiliation(s)
- Ennio Idrobo-Ávila
- Department of Medical InformaticsUniversity Medical Center Göttingen, Georg-August-Universität37075GöttingenGermany
| | - Gergő Bognár
- Department of Numerical Analysis, Faculty of InformaticsEötvös Loránd University1117BudapestHungary
| | - Dagmar Krefting
- Department of Medical InformaticsUniversity Medical Center Göttingen, Georg-August-Universität37075GöttingenGermany
| | - Thomas Penzel
- Interdisciplinary Center of Sleep MedicineCharité - Universitätsmedizin Berlin10117BerlinGermany
| | - Péter Kovács
- Department of Numerical Analysis, Faculty of InformaticsEötvös Loránd University1117BudapestHungary
| | - Nicolai Spicher
- Department of Medical InformaticsUniversity Medical Center Göttingen, Georg-August-Universität37075GöttingenGermany
| |
Collapse
|
4
|
Wu BF, Chiu LW, Wu YC, Lai CC, Cheng HM, Chu PH. Contactless Blood Pressure Measurement Via Remote Photoplethysmography With Synthetic Data Generation Using Generative Adversarial Networks. IEEE J Biomed Health Inform 2024; 28:621-632. [PMID: 37037253 DOI: 10.1109/jbhi.2023.3265857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
Abstract
Remote photoplethysmography (rPPG) has been used to measure vital signs such as heart rate, heart rate variability, blood pressure (BP), and blood oxygen. Recent studies adopt features developed with photoplethysmography (PPG) to achieve contactless BP measurement via rPPG. These features can be classified into two groups: time or phase differences from multiple signals, or waveform feature analysis from a single signal. Here we devise a solution to extract the time difference information from the rPPG signal captured at 30 FPS. We also propose a deep learning model architecture to estimate BP from the extracted features. To prevent overfitting and compensate for the lack of data, we leverage a multi-model design and generate synthetic data. We also use subject information related to BP to assist in model learning. For real-world usage, the subject information is replaced with values estimated from face images, with performance that is still better than the state-of-the-art. To our best knowledge, the improvements can be achieved because of: 1) the model selection with estimated subject information, 2) replacing the estimated subject information with the real one, 3) the InfoGAN assistance training (synthetic data generation), and 4) the time difference features as model input. To evaluate the performance of the proposed method, we conduct a series of experiments, including dynamic BP measurement for many single subjects and nighttime BP measurement with infrared lighting. Our approach reduces the MAE from 15.49 to 8.78 mmHg for systolic blood pressure (SBP) and 10.56 to 6.16 mmHg for diastolic blood pressure(DBP) on a self-constructed rPPG dataset. On the Taipei Veterans General Hospital(TVGH) dataset for nighttime applications, the MAE is reduced from 21.58 to 11.12 mmHg for SBP and 9.74 to 7.59 mmHg for DBP, with improvement ratios of 48.47% and 22.07% respectively.
Collapse
|
5
|
Jiang X, Zhang J, Mu W, Wang K, Li L, Zhang L. TRCCBP: Transformer Network for Radar-Based Contactless Continuous Blood Pressure Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:9680. [PMID: 38139525 PMCID: PMC10747831 DOI: 10.3390/s23249680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 11/10/2023] [Accepted: 11/28/2023] [Indexed: 12/24/2023]
Abstract
Contactless continuous blood pressure (BP) monitoring is of great significance for daily healthcare. Radar-based continuous monitoring methods typically extract time-domain features manually such as pulse transit time (PTT) to calculate the BP. However, breathing and slight body movements usually distort the features extracted from pulse-wave signals, especially in long-term continuous monitoring, and manually extracted features may have limited performance for BP estimation. This article proposes a Transformer network for Radar-based Contactless Continuous Blood Pressure monitoring (TRCCBP). A heartbeat signal-guided single-beat pulse wave extraction method is designed to obtain pure pulse-wave signals. A transformer network-based blood pressure estimation network is proposed to estimate BP, which utilizes convolutional layers with different scales, a gated recurrent unit (GRU) to capture time-dependence in continuous radar signal and multi-head attention modules to capture deep temporal domain characteristics. A radar signal dataset captured in an indoor environment containing 31 persons and a real medical situation containing five persons is set up to evaluate the performance of TRCCBP. Compared with the state-of-the-art method, the average accuracy of diastolic blood pressure (DBP) and systolic blood pressure (SBP) is 4.49 mmHg and 4.73 mmHg, improved by 12.36 mmHg and 8.80 mmHg, respectively. The proposed TRCCBP source codes and radar signal dataset have been made open-source online for further research.
Collapse
Affiliation(s)
- Xikang Jiang
- School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China; (X.J.)
| | - Jinhui Zhang
- Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Wenyao Mu
- School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China; (X.J.)
| | - Kun Wang
- Logistic Support Center, Chinese PLA General Hospital, Beijing 100853, China
| | - Lei Li
- School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China; (X.J.)
| | - Lin Zhang
- School of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100876, China; (X.J.)
| |
Collapse
|
6
|
Kyung J, Choi JH, Seong JS, Jeoung YR, Chang JH. A Multi-modal Teacher-student Framework for Improved Blood Pressure Estimation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-5. [PMID: 38082962 DOI: 10.1109/embc40787.2023.10340352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Blood pressure (BP) is a critical vital sign that hypertensive patients regularly measure. In this study, we propose a novel BP estimation framework to distill the knowledge from a multi-modal model to a uni-modal BP estimation model through teacher-student training. The multi-modal BP estimation model consists of three components: first, a gated recurrent unit network that generates features from photoplethysmogram, electrocardiogram, age, height, and weight; second, an attention mechanism that integrates each feature into joint embeddings; and third, a regression layer that estimates BP from the joint embeddings. The uni-modal BP estimation model has similar components to the multi-modal model but uses only PPG signal. BP is predicted by the embeddings extracted from the uni-modal model, and these embeddings are trained to be as similar as possible to the joint embeddings extracted from the multi-modal model. The proposed method demonstrates absolute prediction errors of 5.24±6.41 and 3.49±3.85 mmHg for systolic blood pressure and diastolic blood pressure in the MIMIC-III dataset, satisfying the AAMI standard.
Collapse
|
7
|
Ghosh A, Sarkar S, Liu H, Mandal S. Boosting Algorithms based Cuff-less Blood Pressure Estimation from Clinically Relevant ECG and PPG Morphological Features. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-6. [PMID: 38082568 DOI: 10.1109/embc40787.2023.10340405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Blood Pressure (BP) is often coined as a critical physiological marker for cardiovascular health. Multiple studies have explored either Photoplethysmogram (PPG) or ECG-PPG derived features for continuous BP estimation using machine learning (ML); deep learning (DL) techniques. Majority of those derived features often lack a stringent biological explanation and are not significantly correlated with BP. In this paper, we identified several clinically relevant (bio-inspired) ECG and PPG features; and exploited them to estimate Systolic (SBP), and Diastolic Blood Pressure (DBP) values using CatBoost, and AdaBoost algorithms. The estimation performance was then compared against popular ML algorithms. SBP and DBP achieved a Pearson's correlation coefficient of 0.90 and 0.83 between estimated and target BP values. The estimated mean absolute error (MAE) values are 3.81 and 2.22 mmHg with a Standard Deviation of 6.24 and 3.51 mmHg, respectively, for SBP and DBP using CatBoost. The results surpassed the Advancement of Medical Instrumentation (AAMI) standards. For the British Hypertension Society (BHS) protocol, the results achieved for all the BP categories resided in Grade A. Further investigation reveals that bio-inspired features along with tuned ML models can produce comparable results w.r.t parameter-intensive DL networks. ln(HR × mNPV), HR, BMI index, ageing index, and PPG-K point were identified as the top five key features for estimating BP. The group-based analysis further concludes that a trade-off lies between the number of features and MAE. Increasing the no. of features beyond a certain threshold saturates the reduction in MAE.
Collapse
|
8
|
Kasbekar RS, Ji S, Clancy EA, Goel A. Optimizing the input feature sets and machine learning algorithms for reliable and accurate estimation of continuous, cuffless blood pressure. Sci Rep 2023; 13:7750. [PMID: 37173370 PMCID: PMC10181996 DOI: 10.1038/s41598-023-34677-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023] Open
Abstract
The advent of mobile devices, wearables and digital healthcare has unleashed a demand for accurate, reliable, and non-interventional ways to measure continuous blood pressure (BP). Many consumer products claim to measure BP with a cuffless device, but their lack of accuracy and reliability limit clinical adoption. Here, we demonstrate how multimodal feature datasets, comprising: (i) pulse arrival time (PAT); (ii) pulse wave morphology (PWM), and (iii) demographic data, can be combined with optimized Machine Learning (ML) algorithms to estimate Systolic BP (SBP), Diastolic BP (DBP) and Mean Arterial Pressure (MAP) within a 5 mmHg bias of the gold standard Intra-Arterial BP, well within the acceptable limits of the IEC/ANSI 80601-2-30 (2018) standard. Furthermore, DBP's calculated using 126 datasets collected from 31 hemodynamically compromised patients had a standard deviation within 8 mmHg, while SBP's and MAP's exceeded these limits. Using ANOVA and Levene's test for error means and standard deviations, we found significant differences in the various ML algorithms but found no significant differences amongst the multimodal feature datasets. Optimized ML algorithms and key multimodal features obtained from larger real-world data (RWD) sets could enable more reliable and accurate estimation of continuous BP in cuffless devices, accelerating wider clinical adoption.
Collapse
Affiliation(s)
- Rajesh S Kasbekar
- Department of Biomedical Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA, USA.
| | - Songbai Ji
- Department of Biomedical Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA, USA
| | - Edward A Clancy
- Department of Biomedical Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA, USA
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute (WPI), Worcester, MA, USA
| | - Anita Goel
- Nanobiosym Research Institute, Nanobiosym, Inc. and Department of Physics, Harvard University, Cambridge, MA, USA
| |
Collapse
|
9
|
闫 昊, 李 霞, 朱 田, 陈 修, 龚 宁, 周 秦. [A non-contact continuous blood pressure measurement method based on video stream]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2023; 40:249-256. [PMID: 37139755 PMCID: PMC10162922 DOI: 10.7507/1001-5515.202211071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/28/2023] [Indexed: 05/05/2023]
Abstract
Hypertension is the primary disease that endangers human health. A convenient and accurate blood pressure measurement method can help to prevent the hypertension. This paper proposed a continuous blood pressure measurement method based on facial video signal. Firstly, color distortion filtering and independent component analysis were used to extract the video pulse wave of the region of interest in the facial video signal, and the multi-dimensional feature extraction of the pulse wave was preformed based on the time-frequency domain and physiological principles; Secondly, an integrated feature selection method was designed to extract the universal optimal feature subset; After that, we compared the single person blood pressure measurement models established by Elman neural network based on particle swarm optimization, support vector machine (SVM) and deep belief network; Finally, we used SVM algorithm to build a general blood pressure prediction model, which was compared and evaluated with the real blood pressure value. The experimental results showed that the blood pressure measurement results based on facial video were in good agreement with the standard blood pressure values. Comparing the estimated blood pressure from the video with standard blood pressure value, the mean absolute error (MAE) of systolic blood pressure was 4.9 mm Hg with a standard deviation (STD) of 5.9 mm Hg, and the MAE of diastolic blood pressure was 4.6 mm Hg with a STD of 5.0 mm Hg, which met the AAMI standards. The non-contact blood pressure measurement method based on video stream proposed in this paper can be used for blood pressure measurement.
Collapse
Affiliation(s)
- 昊 闫
- 西安交通大学 生命科学与技术学院(西安 710049)School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - 霞 李
- 西安交通大学 生命科学与技术学院(西安 710049)School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - 田杨 朱
- 西安交通大学 生命科学与技术学院(西安 710049)School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - 修强 陈
- 西安交通大学 生命科学与技术学院(西安 710049)School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - 宁 龚
- 西安交通大学 生命科学与技术学院(西安 710049)School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - 秦武 周
- 西安交通大学 生命科学与技术学院(西安 710049)School of Life Science and Technology, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| |
Collapse
|
10
|
Multi-Task Classification of Physical Activity and Acute Psychological Stress for Advanced Diabetes Treatment. SIGNALS 2023. [DOI: 10.3390/signals4010009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023] Open
Abstract
Wearable sensor data can be integrated and interpreted to improve the treatment of chronic conditions, such as diabetes, by enabling adjustments in treatment decisions based on physical activity and psychological stress assessments. The challenges in using biological analytes to frequently detect physical activity (PA) and acute psychological stress (APS) in daily life necessitate the use of data from noninvasive sensors in wearable devices, such as wristbands. We developed a recurrent multi-task deep neural network (NN) with long-short-term-memory architecture to integrate data from multiple sensors (blood volume pulse, skin temperature, galvanic skin response, three-axis accelerometers) and simultaneously detect and classify the type of PA, namely, sedentary state, treadmill run, stationary bike, and APS, such as non-stress, emotional anxiety stress, mental stress, and estimate the energy expenditure (EE). The objective was to assess the feasibility of using the multi-task recurrent NN (RNN) rather than independent RNNs for detection and classification of AP and APS. The multi-task RNN achieves comparable performance to independent RNNs, with the multi-task RNN having F1 scores of 98.00% for PA and 98.97% for APS, and a root mean square error (RMSE) of 0.728 calhr.kg for EE estimation for testing data. The independent RNNs have F1 scores of 99.64% for PA and 98.83% for APS, and an RMSE of 0.666 calhr.kg for EE estimation. The results indicate that a multi-task RNN can effectively interpret the signals from wearable sensors. Additionally, we developed individual and multi-task extreme gradient boosting (XGBoost) for separate and simultaneous classification of PA types and APS types. Multi-task XGBoost achieved F1 scores of 99.89% and 98.31% for the classification of PA types and APS types, respectively, while the independent XGBoost achieved F1 scores of 99.68% and 96.77%, respectively. The results indicate that both multi-task RNN and XGBoost can be used for the detection and classification of PA and APS without loss of performance with respect to individual separate classification systems. People with diabetes can achieve better outcomes and quality of life by including physical activity and psychological stress assessments in treatment decision-making.
Collapse
|
11
|
Wang W, Mohseni P, Kilgore KL, Najafizadeh L. PulseDB: A large, cleaned dataset based on MIMIC-III and VitalDB for benchmarking cuff-less blood pressure estimation methods. Front Digit Health 2023; 4:1090854. [PMID: 36844249 PMCID: PMC9944565 DOI: 10.3389/fdgth.2022.1090854] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 12/28/2022] [Indexed: 02/10/2023] Open
Abstract
There has been a growing interest in developing cuff-less blood pressure (BP) estimation methods to enable continuous BP monitoring from electrocardiogram (ECG) and/or photoplethysmogram (PPG) signals. The majority of these methods have been evaluated using publicly-available datasets, however, there exist significant discrepancies across studies with respect to the size, the number of subjects, and the applied pre-processing steps for the data that is eventually used for training and testing the models. Such differences make conducting performance comparison across models largely unfair, and mask the generalization capability of various BP estimation methods. To fill this important gap, this paper presents "PulseDB," the largest cleaned dataset to date, for benchmarking BP estimation models that also fulfills the requirements of standardized testing protocols. PulseDB contains 1) 5,245,454 high-quality 10 -s segments of ECG, PPG, and arterial BP (ABP) waveforms from 5,361 subjects retrieved from the MIMIC-III waveform database matched subset and the VitalDB database; 2) subjects' identification and demographic information, that can be utilized as additional input features to improve the performance of BP estimation models, or to evaluate the generalizability of the models to data from unseen subjects; and 3) positions of the characteristic points of the ECG/PPG signals, making PulseDB directly usable for training deep learning models with minimal data pre-processing. Additionally, using this dataset, we conduct the first study to provide insights about the performance gap between calibration-based and calibration-free testing approaches for evaluating generalizability of the BP estimation models. We expect PulseDB, as a user-friendly, large, comprehensive and multi-functional dataset, to be used as a reliable source for the evaluation of cuff-less BP estimation methods.
Collapse
Affiliation(s)
- Weinan Wang
- Integrated Systems and NeuroImaging Laboratory, Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, United States
| | - Pedram Mohseni
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH, United States
| | - Kevin L. Kilgore
- Department of Physical Medicine & Rehabilitation, Case Western Reserve University and The MetroHealth System, Cleveland, OH, United States
| | - Laleh Najafizadeh
- Integrated Systems and NeuroImaging Laboratory, Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ, United States
| |
Collapse
|
12
|
Wong MKF, Hei H, Lim SZ, Ng EYK. Applied machine learning for blood pressure estimation using a small, real-world electrocardiogram and photoplethysmogram dataset. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2023; 20:975-997. [PMID: 36650798 DOI: 10.3934/mbe.2023045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Applying machine learning techniques to electrocardiography and photoplethysmography signals and their multivariate-derived waveforms is an ongoing effort to estimate non-occlusive blood pressure. Unfortunately, real ambulatory electrocardiography and photoplethysmography waveforms are inevitably affected by motion and noise artifacts, so established machine learning architectures perform poorly when trained on data of the Multiparameter Intelligent Monitoring in Intensive Care II type, a publicly available ICU database. Our study addresses this problem by applying four well-established machine learning methods, i.e., random forest regression, support vector regression, Adaboost regression and artificial neural networks, to a small, self-sampled electrocardiography-photoplethysmography dataset (n = 54) to improve the robustness of machine learning to real-world BP estimates. We evaluated the performance using a selection of optimal feature morphologies of waveforms by using pulse arrival time, morphological and frequency photoplethysmography parameters and heart rate variability as characterization data. On the basis of the root mean square error and mean absolute error, our study showed that support vector regression gave the best performance for blood pressure estimation from noisy data, achieving an mean absolute error of 6.97 mmHg, which meets the level C criteria set by the British Hypertension Society. We demonstrate that ambulatory electrocardiography- photoplethysmography signals acquired by mobile discrete devices can be used to estimate blood pressure.
Collapse
Affiliation(s)
- Mark Kei Fong Wong
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
| | - Hao Hei
- School of Electrical and Electronic Engineering, Nanyang Technological University, 639798, Singapore
| | - Si Zhou Lim
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
| | - Eddie Yin-Kwee Ng
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 639798, Singapore
| |
Collapse
|
13
|
Qin K, Huang W, Zhang T, Tang S. Machine learning and deep learning for blood pressure prediction: a methodological review from multiple perspectives. Artif Intell Rev 2022. [DOI: 10.1007/s10462-022-10353-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
14
|
Khan Mamun MMR, Sherif A. Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 10:bioengineering10010027. [PMID: 36671599 PMCID: PMC9854981 DOI: 10.3390/bioengineering10010027] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022]
Abstract
Hypertension is a chronic condition that is one of the prominent reasons behind cardiovascular disease, brain stroke, and organ failure. Left unnoticed and untreated, the deterioration in a health condition could even result in mortality. If it can be detected early, with proper treatment, undesirable outcomes can be avoided. Until now, the gold standard is the invasive way of measuring blood pressure (BP) using a catheter. Additionally, the cuff-based and noninvasive methods are too cumbersome or inconvenient for frequent measurement of BP. With the advancement of sensor technology, signal processing techniques, and machine learning algorithms, researchers are trying to find the perfect relationships between biomedical signals and changes in BP. This paper is a literature review of the studies conducted on the cuffless noninvasive measurement of BP using biomedical signals. Relevant articles were selected using specific criteria, then traditional techniques for BP measurement were discussed along with a motivation for cuffless measurement use of biomedical signals and machine learning algorithms. The review focused on the progression of different noninvasive cuffless techniques rather than comparing performance among different studies. The literature survey concluded that the use of deep learning proved to be the most accurate among all the cuffless measurement techniques. On the other side, this accuracy has several disadvantages, such as lack of interpretability, computationally extensive, standard validation protocol, and lack of collaboration with health professionals. Additionally, the continuing work by researchers is progressing with a potential solution for these challenges. Finally, future research directions have been provided to encounter the challenges.
Collapse
Affiliation(s)
| | - Ahmed Sherif
- School of Computing Sciences and Computer Engineering, The University of Southern Mississippi, Hattiesburg, MS 39406, USA
| |
Collapse
|
15
|
Fuadah YN, Lim KM. Classification of Blood Pressure Levels Based on Photoplethysmogram and Electrocardiogram Signals with a Concatenated Convolutional Neural Network. Diagnostics (Basel) 2022; 12:diagnostics12112886. [PMID: 36428946 PMCID: PMC9689744 DOI: 10.3390/diagnostics12112886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 11/04/2022] [Accepted: 11/16/2022] [Indexed: 11/23/2022] Open
Abstract
Hypertension is a severe public health issue worldwide that significantly increases the risk of cardiac vascular disease, stroke, brain hemorrhage, and renal dysfunction. Early screening of blood pressure (BP) levels is essential to prevent the dangerous complication associated with hypertension as the leading cause of death. Recent studies have focused on employing photoplethysmograms (PPG) with machine learning to classify BP levels. However, several studies claimed that electrocardiograms (ECG) also strongly correlate with blood pressure. Therefore, we proposed a concatenated convolutional neural network which integrated the features extracted from PPG and ECG signals. This study used the MIMIC III dataset, which provided PPG, ECG, and arterial blood pressure (ABP) signals. A total of 14,298 signal segments were obtained from 221 patients, which were divided into 9150 signals of train data, 2288 signals of validation data, and 2860 signals of test data. In the training process, five-fold cross-validation was applied to select the best model with the highest classification performance. The proposed concatenated CNN architecture using PPG and ECG obtained the highest test accuracy of 94.56-95.15% with a 95% confidence interval in classifying BP levels into hypotension, normotension, prehypertension, hypertension stage 1, and hypertension stage 2. The result shows that the proposed method is a promising solution to categorize BP levels effectively, assisting medical personnel in making a clinical diagnosis.
Collapse
Affiliation(s)
- Yunendah Nur Fuadah
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- School of Electrical Engineering, Telkom University, Bandung 40257, Indonesia
| | - Ki Moo Lim
- Computational Medicine Lab, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Computational Medicine Lab, Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Republic of Korea
- Correspondence:
| |
Collapse
|
16
|
Ku CJ, Wang Y, Chang CY, Wu MT, Dai ST, Liao LD. Noninvasive blood oxygen, heartbeat rate, and blood pressure parameter monitoring by photoplethysmography signals. Heliyon 2022; 8:e11698. [DOI: 10.1016/j.heliyon.2022.e11698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/02/2022] [Accepted: 11/10/2022] [Indexed: 11/19/2022] Open
|
17
|
Man PK, Cheung KL, Sangsiri N, Shek WJ, Wong KL, Chin JW, Chan TT, So RHY. Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring. Healthcare (Basel) 2022; 10:healthcare10102113. [PMID: 36292560 PMCID: PMC9601911 DOI: 10.3390/healthcare10102113] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 09/26/2022] [Accepted: 10/02/2022] [Indexed: 11/04/2022] Open
Abstract
Blood pressure (BP) determines whether a person has hypertension and offers implications as to whether he or she could be affected by cardiovascular disease. Cuff-based sphygmomanometers have traditionally provided both accuracy and reliability, but they require bulky equipment and relevant skills to obtain precise measurements. BP measurement from photoplethysmography (PPG) signals has become a promising alternative for convenient and unobtrusive BP monitoring. Moreover, the recent developments in remote photoplethysmography (rPPG) algorithms have enabled new innovations for contactless BP measurement. This paper illustrates the evolution of BP measurement techniques from the biophysical theory, through the development of contact-based BP measurement from PPG signals, and to the modern innovations of contactless BP measurement from rPPG signals. We consolidate knowledge from a diverse background of academic research to highlight the importance of multi-feature analysis for improving measurement accuracy. We conclude with the ongoing challenges, opportunities, and possible future directions in this emerging field of research.
Collapse
Affiliation(s)
- Ping-Kwan Man
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Correspondence:
| | - Kit-Leong Cheung
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Computer Science and Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Nawapon Sangsiri
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Computer Science and Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Wilfred Jin Shek
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Biomedical Sciences, King’s College London, London WC2R 2LS, UK
| | - Kwan-Long Wong
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| | - Jing-Wei Chin
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| | - Tsz-Tai Chan
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| | - Richard Hau-Yue So
- PanopticAI, Hong Kong Science and Technology Parks, New Territories, Hong Kong, China
- Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China
| |
Collapse
|
18
|
Fleischhauer V, Feldheiser A, Zaunseder S. Beat-to-Beat Blood Pressure Estimation by Photoplethysmography and Its Interpretation. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22187037. [PMID: 36146386 PMCID: PMC9506534 DOI: 10.3390/s22187037] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 08/29/2022] [Accepted: 09/13/2022] [Indexed: 05/28/2023]
Abstract
Blood pressure (BP) is among the most important vital signals. Estimation of absolute BP solely using photoplethysmography (PPG) has gained immense attention over the last years. Available works differ in terms of used features as well as classifiers and bear large differences in their results. This work aims to provide a machine learning method for absolute BP estimation, its interpretation using computational methods and its critical appraisal in face of the current literature. We used data from three different sources including 273 subjects and 259,986 single beats. We extracted multiple features from PPG signals and its derivatives. BP was estimated by xgboost regression. For interpretation we used Shapley additive values (SHAP). Absolute systolic BP estimation using a strict separation of subjects yielded a mean absolute error of 9.456mmHg and correlation of 0.730. The results markedly improve if data separation is changed (MAE: 6.366mmHg, r: 0.874). Interpretation by means of SHAP revealed four features from PPG, its derivation and its decomposition to be most relevant. The presented approach depicts a general way to interpret multivariate prediction algorithms and reveals certain features to be valuable for absolute BP estimation. Our work underlines the considerable impact of data selection and of training/testing separation, which must be considered in detail when algorithms are to be compared. In order to make our work traceable, we have made all methods available to the public.
Collapse
Affiliation(s)
- Vincent Fleischhauer
- Faculty of Information Technology, University of Applied Sciences and Arts Dortmund, 44139 Dortmund, Germany
- TU Dresden, Institute for Biomedical Engineering, 01069 Dresden, Germany
| | - Aarne Feldheiser
- Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, Evang. Kliniken Essen-Mitte, Huyssens-Stiftung/Knappschaft, 45136 Essen, Germany
- Department of Anaesthesiology and Operative Intensive Care Medicine (CCM, CVK), Charité—Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, 13353 Berlin, Germany
| | - Sebastian Zaunseder
- Faculty of Information Technology, University of Applied Sciences and Arts Dortmund, 44139 Dortmund, Germany
- TU Dresden, Institute for Biomedical Engineering, 01069 Dresden, Germany
| |
Collapse
|
19
|
Ismail SNA, Nayan NA, Jaafar R, May Z. Recent Advances in Non-Invasive Blood Pressure Monitoring and Prediction Using a Machine Learning Approach. SENSORS (BASEL, SWITZERLAND) 2022; 22:6195. [PMID: 36015956 PMCID: PMC9412312 DOI: 10.3390/s22166195] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/25/2022] [Accepted: 08/04/2022] [Indexed: 06/15/2023]
Abstract
Blood pressure (BP) monitoring can be performed either invasively via arterial catheterization or non-invasively through a cuff sphygmomanometer. However, for conscious individuals, traditional cuff-based BP monitoring devices are often uncomfortable, intermittent, and impractical for frequent measurements. Continuous and non-invasive BP (NIBP) monitoring is currently gaining attention in the human health monitoring area due to its promising potentials in assessing the health status of an individual, enabled by machine learning (ML), for various purposes such as early prediction of disease and intervention treatment. This review presents the development of a non-invasive BP measuring tool called sphygmomanometer in brief, summarizes state-of-the-art NIBP sensors, and identifies extended works on continuous NIBP monitoring using commercial devices. Moreover, the NIBP predictive techniques including pulse arrival time, pulse transit time, pulse wave velocity, and ML are elaborated on the basis of bio-signals acquisition from these sensors. Additionally, the different BP values (systolic BP, diastolic BP, mean arterial pressure) of the various ML models adopted in several reported studies are compared in terms of the international validation standards developed by the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) for clinically-approved BP monitors. Finally, several challenges and possible solutions for the implementation and realization of continuous NIBP technology are addressed.
Collapse
Affiliation(s)
- Siti Nor Ashikin Ismail
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
| | - Nazrul Anuar Nayan
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
- Institute Islam Hadhari, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
| | - Rosmina Jaafar
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
| | - Zazilah May
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
- Electrical and Electronic Engineering Department, Universiti Teknologi Petronas, Seri Iskandar 32610, Perak, Malaysia
| |
Collapse
|
20
|
Petmezas G, Stefanopoulos L, Kilintzis V, Tzavelis A, Rogers JA, Katsaggelos AK, Maglaveras N. State-of-the-art Deep Learning Methods on Electrocardiogram Data: A Systematic Review (Preprint). JMIR Med Inform 2022; 10:e38454. [PMID: 35969441 PMCID: PMC9425174 DOI: 10.2196/38454] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2022] [Revised: 06/03/2022] [Accepted: 07/03/2022] [Indexed: 11/13/2022] Open
Abstract
Background Electrocardiogram (ECG) is one of the most common noninvasive diagnostic tools that can provide useful information regarding a patient’s health status. Deep learning (DL) is an area of intense exploration that leads the way in most attempts to create powerful diagnostic models based on physiological signals. Objective This study aimed to provide a systematic review of DL methods applied to ECG data for various clinical applications. Methods The PubMed search engine was systematically searched by combining “deep learning” and keywords such as “ecg,” “ekg,” “electrocardiogram,” “electrocardiography,” and “electrocardiology.” Irrelevant articles were excluded from the study after screening titles and abstracts, and the remaining articles were further reviewed. The reasons for article exclusion were manuscripts written in any language other than English, absence of ECG data or DL methods involved in the study, and absence of a quantitative evaluation of the proposed approaches. Results We identified 230 relevant articles published between January 2020 and December 2021 and grouped them into 6 distinct medical applications, namely, blood pressure estimation, cardiovascular disease diagnosis, ECG analysis, biometric recognition, sleep analysis, and other clinical analyses. We provide a complete account of the state-of-the-art DL strategies per the field of application, as well as major ECG data sources. We also present open research problems, such as the lack of attempts to address the issue of blood pressure variability in training data sets, and point out potential gaps in the design and implementation of DL models. Conclusions We expect that this review will provide insights into state-of-the-art DL methods applied to ECG data and point to future directions for research on DL to create robust models that can assist medical experts in clinical decision-making.
Collapse
Affiliation(s)
- Georgios Petmezas
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Leandros Stefanopoulos
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Vassilis Kilintzis
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Andreas Tzavelis
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States
| | - John A Rogers
- Department of Material Science, Northwestern University, Evanston, IL, United States
| | - Aggelos K Katsaggelos
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL, United States
| | - Nicos Maglaveras
- Lab of Computing, Medical Informatics and Biomedical-Imaging Technologies, The Medical School, Aristotle University of Thessaloniki, Thessaloniki, Greece
| |
Collapse
|
21
|
Phan DT, Nguyen CH, Nguyen TDP, Tran LH, Park S, Choi J, Lee BI, Oh J. A Flexible, Wearable, and Wireless Biosensor Patch with Internet of Medical Things Applications. BIOSENSORS 2022; 12:bios12030139. [PMID: 35323409 PMCID: PMC8945966 DOI: 10.3390/bios12030139] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 02/19/2022] [Accepted: 02/20/2022] [Indexed: 05/05/2023]
Abstract
Monitoring the vital signs and physiological responses of the human body in daily activities is particularly useful for the early diagnosis and prevention of cardiovascular diseases. Here, we proposed a wireless and flexible biosensor patch for continuous and longitudinal monitoring of different physiological signals, including body temperature, blood pressure (BP), and electrocardiography. Moreover, these modalities for tracking body movement and GPS locations for emergency rescue have been included in biosensor devices. We optimized the flexible patch design with high mechanical stretchability and compatibility that can provide reliable and long-term attachment to the curved skin surface. Regarding smart healthcare applications, this research presents an Internet of Things-connected healthcare platform consisting of a smartphone application, website service, database server, and mobile gateway. The IoT platform has the potential to reduce the demand for medical resources and enhance the quality of healthcare services. To further address the advances in non-invasive continuous BP monitoring, an optimized deep learning architecture with one-channel electrocardiogram signals is introduced. The performance of the BP estimation model was verified using an independent dataset; this experimental result satisfied the Association for the Advancement of Medical Instrumentation, and the British Hypertension Society standards for BP monitoring devices. The experimental results demonstrated the practical application of the wireless and flexible biosensor patch for continuous physiological signal monitoring with Internet of Medical Things-connected healthcare applications.
Collapse
Affiliation(s)
- Duc Tri Phan
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Cong Hoan Nguyen
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Thuy Dung Pham Nguyen
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Le Hai Tran
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Sumin Park
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Jaeyeop Choi
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
| | - Byeong-il Lee
- Department of Smart Healthcare, Pukyong National University, Busan 48513, Korea
- Correspondence: (B.-i.L.); (J.O.)
| | - Junghwan Oh
- Industry 4.0 Convergence Bionics Engineering, Pukyong National University, Busan 48513, Korea; (D.T.P.); (C.H.N.); (T.D.P.N.); (L.H.T.); (S.P.); (J.C.)
- BK21 FOUR ‘New-Senior’ Oriented Smart Health Care Education, Pukyong National University, Busan 48513, Korea
- Biomedical Engineering, Pukyong National University, Busan 48513, Korea
- Ohlabs Corporation, Busan 48513, Korea
- Correspondence: (B.-i.L.); (J.O.)
| |
Collapse
|
22
|
Schrumpf F, Frenzel P, Aust C, Osterhoff G, Fuchs M. Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning. SENSORS (BASEL, SWITZERLAND) 2021; 21:6022. [PMID: 34577227 PMCID: PMC8472879 DOI: 10.3390/s21186022] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 08/27/2021] [Accepted: 08/30/2021] [Indexed: 11/16/2022]
Abstract
Exploiting photoplethysmography signals (PPG) for non-invasive blood pressure (BP) measurement is interesting for various reasons. First, PPG can easily be measured using fingerclip sensors. Second, camera based approaches allow to derive remote PPG (rPPG) signals similar to PPG and therefore provide the opportunity for non-invasive measurements of BP. Various methods relying on machine learning techniques have recently been published. Performances are often reported as the mean average error (MAE) on the data which is problematic. This work aims to analyze the PPG- and rPPG based BP prediction error with respect to the underlying data distribution. First, we train established neural network (NN) architectures and derive an appropriate parameterization of input segments drawn from continuous PPG signals. Second, we use this parameterization to train NNs with a larger PPG dataset and carry out a systematic evaluation of the predicted blood pressure. The analysis revealed a strong systematic increase of the prediction error towards less frequent BP values across NN architectures. Moreover, we tested different train/test set split configurations which underpin the importance of a careful subject-aware dataset assignment to prevent overly optimistic results. Third, we use transfer learning to train the NNs for rPPG based BP prediction. The resulting performances are similar to the PPG-only case. Finally, we apply different personalization techniques and retrain our NNs with subject-specific data for both the PPG-only and rPPG case. Whilst the particular technique is less important, personalization reduces the prediction errors significantly.
Collapse
Affiliation(s)
- Fabian Schrumpf
- Laboratory for Biosignal Processing, Leipzig University of Applied Sciences, 04317 Leipzig, Germany
| | - Patrick Frenzel
- Laboratory for Biosignal Processing, Leipzig University of Applied Sciences, 04317 Leipzig, Germany
| | - Christoph Aust
- Department of Orthopaedics, Trauma and Plastic Surgery, University of Leipzig Medical Center, 04103 Leipzig, Germany
| | - Georg Osterhoff
- Department of Orthopaedics, Trauma and Plastic Surgery, University of Leipzig Medical Center, 04103 Leipzig, Germany
| | - Mirco Fuchs
- Laboratory for Biosignal Processing, Leipzig University of Applied Sciences, 04317 Leipzig, Germany
| |
Collapse
|