1
|
Impact of Smokeless Tobacco on Cardiovascular Disease Risk in a Nigerian Metropolitan City. Cardiovasc Toxicol 2024:10.1007/s12012-024-09862-5. [PMID: 38709447 DOI: 10.1007/s12012-024-09862-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 04/16/2024] [Indexed: 05/07/2024]
Abstract
The use of smokeless tobacco products (STP) as a substitute for tobacco smoking is driving increasing consumption of these products especially in developing countries. The study sought to make comparison of cardiovascular risk profile between chronic STP users and suitably matched tobacco-naïve controls. This is a preliminary report from the cross sectional part of a two-arm prospective study of Smokeless Tobacco Products Composition and Exposure Outcome in Enugu metropolis, Nigeria. Consecutively recruited current Smokeless tobacco users, who had no history of cigarette smoking, aged 18 years and above, residing in selected communities in Enugu metropolis, Nigeria were recruited for the study from October 2022 to July 2023. Age and sex matched non-tobacco users from same localities as the study subjects served as controls. Written informed consent to participate in the study was obtained from all study participants. All participants were screened by the investigators, using the study case report forms, to obtain data on medical history, demographic, clinical, laboratory, and electrocardiographic evaluation. Data from 54 STP-users and 54 non-STP-users (mean age 56.58 ± 8.15 years) were analyzed. Anthropometric parameters were similar in both groups. Smokeless tobacco users had higher erect and supine blood pressure indices as well as greater postural drop in systolic blood pressure. The occurrence of diabetes mellitus (20.37% versus 5.56%) and hypertension (25.93%; 11.11%) was significantly higher in the STP-users than in the non-user population, (p = 0.02192 and 0.04751 respectively). Electrocardiographic evaluation showed significantly increased QTc and dispersions of P-wave, QRS and QT intervals as well as reduced PR interval in STP users. Electrocardiographic abnormalities observed in STP users include left ventricular hypertrophy, left atrial enlargement, ST-segment elevation, short PR interval and long QTc. Use of smokeless tobacco products is associated with increased risk burden of diabetes mellitus and hypertensive heart disease. Electrocardiographic findings linked to STP-use in this study are features consistent with arrhythmia, ventricular repolarization abnormality, myocardial hypertrophy and ischaemia, suggesting that smokeless tobacco products are not safe substitutes for tobacco smoking.
Collapse
|
2
|
Stress and Rest Pulmonary Transit Times Assessed by Cardiovascular Magnetic Resonance. Cardiol Rev 2024; 32:243-247. [PMID: 36728820 PMCID: PMC10994187 DOI: 10.1097/crd.0000000000000495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Acquiring pulmonary circulation parameters as a potential marker of cardiopulmonary function is not new. Methods to obtain these parameters have been developed over time, with the latest being first-pass perfusion sequences in cardiovascular magnetic resonance (CMR). Even though more data on these parameters has been recently published, different nomenclature and acquisition methods are used across studies; some works even reported conflicting data. The most commonly used circulation parameters obtained using CMR include pulmonary transit time (PTT) and pulmonary transit beats (PTB). PTT is the time needed for a contrast agent (typically gadolinium-based) to circulate from the right ventricle (RV) to the left ventricle (LV). PTB is the number of cardiac cycles the process takes. Some authors also include corrected heart rate (HR) versions along with standard PTT. Besides other methods, CMR offers an option to assess stress circulation parameters, but data are minimal. This review aims to summarize the up-to-date findings and provide an overview of the latest progress on this promising, dynamically evolving topic.
Collapse
|
3
|
Single intravenous dose ondansetron induces QT prolongation in adult emergency department patients: a prospective observational study. Int J Emerg Med 2024; 17:49. [PMID: 38566008 PMCID: PMC10988934 DOI: 10.1186/s12245-024-00621-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 03/17/2024] [Indexed: 04/04/2024] Open
Abstract
BACKGROUND Ondansetron is one of the most commonly used drugs in the emergency department (ED) for treating nausea and vomiting, particularly in intravenous (IV) form. Nevertheless, it has been shown to prolong QT interval and increase the risk of ventricular dysrhythmias. This study evaluated the associations between single IV ondansetron dosage and subsequent QTc prolongation in the ED. METHODS In this prospective observational study, a total number of 106 patients presenting to the ED in a 3-month period with nausea and vomiting treated with IV ondansetron were enrolled. QT and QTc intervals were measured at baseline (QT0 and QTc0), and 60 min (QT60 and QTc60) following a single-dose administration of ondansetron at 4 or 8 mg doses. To evaluate the predictive ability of these variables, we employed receiver operating characteristic (ROC) curve analyses. RESULTS The predictive models for QTc prolongation 1-hour post-ondansetron administration showed the following: at baseline, the area under curve of 0.70 for QT, 0.71 for QTc, and 0.64 for dosage. Conversely, a QTc0 = 375 msec indicated a QTc60 > 480 msec with a specificity of 97%. Additionally, a QTc0 of 400 msec had a sensitivity of 100% in predicting a QTc60 < 480 msec, while a QTc0 > 460 msec predicted a QTc60 > 480 msec with a specificity of 98%. Moreover, 8 mg doses were associated with higher rates of QTc60 prolongation, while 4 mg doses favored maintaining QTc60 within normal limits. CONCLUSIONS Our study demonstrates the predictive capacity of QT0, QTc0, and ondansetron dosage in forecasting QTc60 prolongation (> 480 msec) post-ondansetron administration. These findings advocate for their incorporation into clinical protocols to enhance safety monitoring in adult ED patients.
Collapse
|
4
|
Relationship between Alzheimer dementia and QT interval: A meta-analysis. Aging Med (Milton) 2024; 7:214-223. [PMID: 38725696 PMCID: PMC11077339 DOI: 10.1002/agm2.12291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/20/2024] [Accepted: 01/28/2024] [Indexed: 05/12/2024] Open
Abstract
While the link between aging and mortality from dementia is widely appreciated, the mechanism is not clear. The objective of this study was to determine whether there is a direct relationship between Alzheimer dementia (AD) and the QT interval, because the latter has been related to cardiac mortality. A systematic review and meta-analysis were conducted after a Medline and EMBASE search using terms "Alzheimer disease or Dementia AND QT interval, QT dispersion or cardiac repolarization." Four studies with control groups were identified. There were significant differences in QT interval between individuals with AD vs individuals without dementia (controls) (odds ratio (OR)1.665 [random effects model] and 1.879 [fixed effect model]) (p < 0.001). There were significant differences in QT interval between individuals with AD vs individuals with mild cognitive impairment (MCI) (OR 1.760 [random effects] and 1.810 [fixed effect]) (p < 0.001). A significant (p <0.001) correlation exists between the QTc and the Mini-Mental State Exam (MMSE), a test of cognitive function. Two studies examined QT variability (the difference between the longest and shortest QT interval on a 12 lead ECG); the OR for QT variability AD vs MCI was 3.858 [random effects model] and 3.712 [fixed effects model] (p < 0.001). When compared to the control group, the OR for QT dispersion in AD was 6.358 [random effects model] or 5.143 ( P< 0.001) [fixed effects model]. A qualitative analysis of the data raised questions about paucity of data defining the nature of the control groups, the pathophysiologic mechanism, and the uniform use of a poor QT heart rate correction factor. The longer QT in AD, greater QT variability in AD, and the direct relationship between QT interval and AD severity supports a brain-heart connection in AD that might be fundamental to aging-induced AD and mortality. Issues with defining the control group, limited number of studies, conflicting data in population studies, and the lack of a strong electrophysiological basis underscore the need for additional research in this field.
Collapse
|
5
|
Electrophysiological Characterization of Subclinical and Overt Hypertrophic Cardiomyopathy by Magnetic Resonance Imaging-Guided Electrocardiography. J Am Coll Cardiol 2024; 83:1042-1055. [PMID: 38385929 PMCID: PMC10945386 DOI: 10.1016/j.jacc.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 02/23/2024]
Abstract
BACKGROUND Ventricular arrhythmia in hypertrophic cardiomyopathy (HCM) relates to adverse structural change and genetic status. Cardiovascular magnetic resonance (CMR)-guided electrocardiographic imaging (ECGI) noninvasively maps cardiac structural and electrophysiological (EP) properties. OBJECTIVES The purpose of this study was to establish whether in subclinical HCM (genotype [G]+ left ventricular hypertrophy [LVH]-), ECGI detects early EP abnormality, and in overt HCM, whether the EP substrate relates to genetic status (G+/G-LVH+) and structural phenotype. METHODS This was a prospective 211-participant CMR-ECGI multicenter study of 70 G+LVH-, 104 LVH+ (51 G+/53 G-), and 37 healthy volunteers (HVs). Local activation time (AT), corrected repolarization time, corrected activation-recovery interval, spatial gradients (GAT/GRTc), and signal fractionation were derived from 1,000 epicardial sites per participant. Maximal wall thickness and scar burden were derived from CMR. A support vector machine was built to discriminate G+LVH- from HV and low-risk HCM from those with intermediate/high-risk score or nonsustained ventricular tachycardia. RESULTS Compared with HV, subclinical HCM showed mean AT prolongation (P = 0.008) even with normal 12-lead electrocardiograms (ECGs) (P = 0.009), and repolarization was more spatially heterogenous (GRTc: P = 0.005) (23% had normal ECGs). Corrected activation-recovery interval was prolonged in overt vs subclinical HCM (P < 0.001). Mean AT was associated with maximal wall thickness; spatial conduction heterogeneity (GAT) and fractionation were associated with scar (all P < 0.05), and G+LVH+ had more fractionation than G-LVH+ (P = 0.002). The support vector machine discriminated subclinical HCM from HV (10-fold cross-validation accuracy 80% [95% CI: 73%-85%]) and identified patients at higher risk of sudden cardiac death (accuracy 82% [95% CI: 78%-86%]). CONCLUSIONS In the absence of LVH or 12-lead ECG abnormalities, HCM sarcomere gene mutation carriers express an aberrant EP phenotype detected by ECGI. In overt HCM, abnormalities occur more severely with adverse structural change and positive genetic status.
Collapse
|
6
|
A Retrospective Comparison of Electrocardiographic Parameters in Ketamine and Tiletamine-Zolazepam Anesthetized Indian Rhesus Monkeys ( Macaca mulatta). Int J Toxicol 2024; 43:184-195. [PMID: 38108647 DOI: 10.1177/10915818231221276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Electrocardiographic evaluation is performed in rhesus monkeys to establish the cardiovascular safety of candidate molecules before progressing to clinical trials. These animals are usually immobilized chemically by ketamine (KTM) and tiletamine-zolazepam (TZ) to obtain a steady-state heart rate and to ensure adequate human safety. The present study aimed to evaluate the effect of these anesthetic regimens on different electrocardiographic parameters. Statistically significant lower HR and higher P-wave duration, RR, QRS, and QT intervals were observed in the KTM-anesthetized group in comparison to TZ-anesthetized animals. No significant changes were noticed in the PR interval and p-wave amplitude. Sex-based significance amongst these parameters was observed in male and female animals of TZ- and KTM-anesthetized groups. Regression analysis of four QTc formulas in TZ-anesthetized rhesus monkeys revealed that QTcNAK (Nakayama) better corrected the QT interval than QTcHAS (Hassimoto), QTcBZT (Bazett), and QTcFRD (Fridericia) formulas. QTcNAK exhibited the least correlation with the RR interval (slope closest to zero and r = .01) and displayed no statistical significance between male and female animals. These data will prove useful in the selection of anesthetic regimens for chemical restraint of rhesus monkeys in nonclinical safety evaluation studies.
Collapse
|
7
|
Risk Stratification of QTc Prolongation in Critically Ill Patients Receiving Antipsychotics for the Management of Delirium Symptoms. J Intensive Care Med 2023:8850666231222470. [PMID: 38130132 DOI: 10.1177/08850666231222470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
BACKGROUND Patients experiencing significant agitation or perceptual disturbances related to delirium in an intensive care setting may benefit from short-term treatment with an antipsychotic medication. Some antipsychotic medications may prolong the QTc interval, which increases the risk of potentially fatal ventricular arrhythmias. In this targeted review, we describe the evidence regarding the relationships between antipsychotic medications and QTc prolongation and practical methods for monitoring the QTc interval and mitigating arrhythmia risk. METHODS Searches of PubMed and Cochrane Library were performed to identify studies, published before February 2023, investigating the relationships between antipsychotic medications and QTc prolongation or arrhythmias. RESULTS Most antipsychotic medications commonly used for the management of delirium symptoms (eg, intravenous haloperidol, olanzapine, quetiapine) cause a moderate degree of QTc prolongation. Among other antipsychotics, those most likely to cause QTc prolongation are iloperidone and ziprasidone, while aripiprazole and lurasidone appear to have minimal risk for QTc prolongation. Genetic vulnerabilities, female sex, older age, pre-existing cardiovascular disease, electrolyte abnormalities, and non-psychiatric medications also increase the risk of QTc prolongation. For individuals at risk of QTc prolongation, it is essential to measure the QTc interval accurately and consistently and consider medication adjustments if needed. CONCLUSIONS Antipsychotic medications are one of many risk factors for QTc prolongation. When managing agitation related to delirium, it is imperative to assess an individual patient's risk for QTc prolongation and to choose a medication and monitoring strategy commensurate to the risks. In intensive care settings, we recommend regular ECG monitoring, using a linear regression formula to correct for heart rate. If substantial QTc prolongation (eg, QTc > 500 msec) is present, a change in pharmacologic treatment can be considered, though a particular medication may still be warranted if the risks of discontinuation (eg, extreme agitation, removal of invasive monitoring devices) outweigh the risks of arrhythmias. AIMS This review aims to summarize the current literature on relationships between antipsychotic medications and QTc prolongation and to make practical clinical recommendations towards the approach of antipsychotic medication use for the management of delirium-related agitation and perceptual disturbances in intensive care settings.
Collapse
|
8
|
Serial electrocardiogram recordings revealed a high prevalence of QT interval prolongation in patients with tuberculosis receiving fluoroquinolones. J Formos Med Assoc 2023; 122:1255-1264. [PMID: 37268474 DOI: 10.1016/j.jfma.2023.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/26/2023] [Accepted: 05/15/2023] [Indexed: 06/04/2023] Open
Abstract
BACKGROUND Fluoroquinolones, crucial components of treatment regimens for drug-resistant tuberculosis (TB), are associated with QT interval prolongation and risks of fatal cardiac arrhythmias. However, few studies have explored dynamic changes in the QT interval in patients receiving QT-prolonging agents. METHODS This prospective cohort study recruited hospitalized patients with TB who received fluoroquinolones. The study investigated the variability of the QT interval by using serial electrocardiograms (ECGs) recorded four times daily. This study analyzed the accuracy of intermittent and single-lead ECG monitoring in detecting QT interval prolongation. RESULTS This study included 32 patients. The mean age was 68.6 ± 13.2 years. The results revealed mild-to-moderate and severe QT interval prolongation in 13 (41%) and 5 (16%) patients, respectively. The incremental yields in sensitivity of one to four daily ECG recordings were 61.0%, 26.1%, 5.6%, and 7.3% in detecting mild-to-moderate QT interval prolongation, and 66.7%, 20.0%, 6.7%, and 6.7% in detecting severe QT interval prolongation. The sensitivity levels of lead II and V5 ECGs in detecting mild-to-moderate and severe QT interval prolongation exceeded 80%, and their specificity levels exceeded 95%. CONCLUSION This study revealed a high prevalence of QT interval prolongation in older patients with TB who receive fluoroquinolones, particularly those with multiple cardiovascular risk factors. Sparsely intermittent ECG monitoring, the prevailing strategy in active drug safety monitoring programs, is inadequate owing to multifactorial and circadian QT interval variability. Additional studies performing serial ECG monitoring are warranted to enhance the understanding of dynamic QT interval changes in patients receiving QT-prolonging anti-TB agents.
Collapse
|
9
|
The optimal QTc selection in patients of acute myocardial infarction with poor perioperative prognosis. BMC Cardiovasc Disord 2023; 23:551. [PMID: 37950189 PMCID: PMC10638740 DOI: 10.1186/s12872-023-03594-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 11/04/2023] [Indexed: 11/12/2023] Open
Abstract
BACKGROUND The predictive utility of QTc values, calculated through various correction formulas for the incidence of postoperative major adverse cardiovascular and cerebrovascular events (MACCE) in patients experiencing acute myocardial infarction (AMI), warrants further exploration. This study endeavors to ascertain the predictive accuracy of disparate QTc values for MACCE occurrences in patients with perioperative AMI. METHODS A retrospective cohort of three hundred fourteen AMI patients, comprising 81 instances of in-hospital MACCE and 233 controls, was assembled, with comprehensive collection of baseline demographic and clinical data. QTc values were derived employing the correction formulas of Bazett, Fridericia, Hodges, Ashman, Framingham, Schlamowitz, Dmitrienko, Rautaharju, and Sarma. Analytical methods encompassed comparative statistics, Spearman correlation analysis, binary logistic regression models, receiver operating characteristic (ROC) curves, and decision curve analysis (DCA). RESULTS QTc values were significantly elevated in the MACCE cohort compared to controls (P < 0.05). Spearman's correlation analysis between heart rate and QTc revealed a modest positive correlation for the Sarma formula (QTcBaz) (ρ = 0.46, P < 0.001). Within the multifactorial binary logistic regression, each QTc variant emerged as an independent risk factor for MACCE, with the Sarma formula-derived QTc (QTcSar) presenting the highest hazard ratio (OR = 1.025). ROC curve analysis identified QTcSar with a threshold of 446 ms as yielding the superior predictive capacity (AUC = 0.734), demonstrating a sensitivity of 60.5% and a specificity of 82.8%. DCA indicated positive net benefits for QTcSar at high-risk thresholds ranging from 0 to 0.66 and 0.71-0.96, with QTcBaz, prevalent in clinical settings, showing positive net benefits at thresholds extending to 0-0.99. CONCLUSION For perioperative AMI patients, QTcSar proves more advantageous in monitoring QTc intervals compared to alternative QT correction formulas, offering enhanced predictive prowess for subsequent MACCE incidents.
Collapse
|
10
|
Cardiac Electromechanical Activity in Healthy Cats and Cats with Cardiomyopathies. SENSORS (BASEL, SWITZERLAND) 2023; 23:8336. [PMID: 37837166 PMCID: PMC10574989 DOI: 10.3390/s23198336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Revised: 10/03/2023] [Accepted: 10/06/2023] [Indexed: 10/15/2023]
Abstract
Optimal heart function depends on perfect synchronization between electrical and mechanical activity. In this pilot study, we aimed to investigate the electromechanical activity of the heart in healthy cats and cats with cardiomyopathy with phonocardiography (PCG) synchronized to an electrocardiography (ECG) pilot device. We included 29 cats (12 healthy cats and 17 cats diagnosed with cardiomyopathy) and performed a clinical examination, PCG synchronized with ECG and echocardiography. We measured the following durations with the pilot PCG device synchronized with ECG: QRS (ventricular depolarization), QT interval (electrical systole), QS1 interval (electromechanical activation time (EMAT)), S1S2 (mechanical systole), QS2 interval (electrical and mechanical systole) and electromechanical window (end of T wave to the beginning of S2). The measured parameters did not differ between healthy cats and cats with cardiomyopathy; however, in cats with cardiomyopathy, EMAT/RR, QS2/RR and S1S2/RR were significantly longer than in healthy cats. This suggests that the hypertrophied myocardium takes longer to generate sufficient pressure to close the mitral valve and that electrical systole, i.e., depolarization and repolarization, and mechanical systoles are longer in cats with cardiomyopathy. The PCG synchronized with the ECG pilot device proved to be a valuable tool for evaluating the electromechanical activity of the feline heart.
Collapse
|
11
|
Correcting bias in cardiac geometries derived from multimodal images using spatiotemporal mapping. Sci Rep 2023; 13:8118. [PMID: 37208380 PMCID: PMC10199025 DOI: 10.1038/s41598-023-33968-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 04/21/2023] [Indexed: 05/21/2023] Open
Abstract
Cardiovascular imaging studies provide a multitude of structural and functional data to better understand disease mechanisms. While pooling data across studies enables more powerful and broader applications, performing quantitative comparisons across datasets with varying acquisition or analysis methods is problematic due to inherent measurement biases specific to each protocol. We show how dynamic time warping and partial least squares regression can be applied to effectively map between left ventricular geometries derived from different imaging modalities and analysis protocols to account for such differences. To demonstrate this method, paired real-time 3D echocardiography (3DE) and cardiac magnetic resonance (CMR) sequences from 138 subjects were used to construct a mapping function between the two modalities to correct for biases in left ventricular clinical cardiac indices, as well as regional shape. Leave-one-out cross-validation revealed a significant reduction in mean bias, narrower limits of agreement, and higher intraclass correlation coefficients for all functional indices between CMR and 3DE geometries after spatiotemporal mapping. Meanwhile, average root mean squared errors between surface coordinates of 3DE and CMR geometries across the cardiac cycle decreased from 7 ± 1 to 4 ± 1 mm for the total study population. Our generalised method for mapping between time-varying cardiac geometries obtained using different acquisition and analysis protocols enables the pooling of data between modalities and the potential for smaller studies to leverage large population databases for quantitative comparisons.
Collapse
|
12
|
Comparison of different QT correction methods for nonclinical safety assessment in ketamine-anesthetized Indian rhesus monkeys ( Macaca mulatta). Toxicol Mech Methods 2023:1-12. [PMID: 36879461 DOI: 10.1080/15376516.2023.2187730] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/08/2023]
Abstract
Rhesus monkeys are a non-rodent species employed in the preclinical safety evaluation of pharmaceuticals and biologics. These nonhuman primate species have been increasingly used in biomedical research because of the similarity in their ionic mechanisms of repolarization with humans. Heart rate and QT interval are two primary endpoints in determining the pro-arrhythmic risk of drugs. As heart rate and QT interval have an inverse relationship, any change in heart rate causes a subsequent change in QT interval. This warrants for calculation of a corrected QT interval. This study aimed to identify an appropriate formula that best corrected QT for change in heart rate. We employed seven formulas based on source-species type, clinical relevance, and requirements of various international regulatory guidelines. Data showed that corrected QT interval values varied drastically for different correction formulas. Equations were compared on their slope values based on QTc versus RR plots. The rank order of the slope for different formulas was (closest to farthest from zero) QTcNAK, QTcHAS, QTcBZT, QTcFRD, QTcVDW, QTcHDG, and QTcFRM. QTcNAK emerged to be the best correcting formula in this study. It showed the least correlation with the RR interval (r = -0.01) and displayed no significant difference amongst the sexes. As there is no universally recognized formula for preclinical use, the authors recommend developing a best-case scenario model for specific study designs and individual organizations. The data from this research will be helpful in deciding an appropriate QT correction formula for the safety assessment of new pharmaceuticals and biologics.
Collapse
|
13
|
An efficient edge/cloud medical system for rapid detection of level of consciousness in emergency medicine based on explainable machine learning models. Neural Comput Appl 2023; 35:10695-10716. [PMID: 37155550 PMCID: PMC10015549 DOI: 10.1007/s00521-023-08258-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 01/06/2023] [Indexed: 03/17/2023]
Abstract
Emergency medicine (EM) is one of the attractive research fields in which researchers investigate their efforts to diagnose and treat unforeseen illnesses or injuries. There are many tests and observations are involved in EM. Detection of the level of consciousness is one of these observations, which can be detected using several methods. Among these methods, the automatic estimation of the Glasgow coma scale (GCS) is studied in this paper. The GCS is a medical score used to describe a patient’s level of consciousness. This type of scoring system requires medical examination that may not be available with the shortage of the medical expert. Therefore, the automatic medical calculation for a patient’s level of consciousness is highly needed. Artificial intelligence has been deployed in several applications and appears to have a high performance regarding providing automatic solutions. The main objective of this work is to introduce the edge/cloud system to improve the efficiency of the consciousness measurement through efficient local data processing. Moreover, an efficient machine learning (ML) model to predict the level of consciousness of a certain patient based on the patient’s demographic, vital signs, and laboratory tests is proposed, as well as maintaining the explainability issue using Shapley additive explanations (SHAP) that provides natural language explanation in a form that helps the medical expert to understand the final prediction. The developed ML model is validated using vital signs and laboratory tests extracted from the MIMIC III dataset, and it achieves superior performance (mean absolute error (MAE) = 0.269, mean square error (MSE) = 0.625, R2 score = 0.964). The resulting model is accurate, medically intuitive, and trustworthy.
Collapse
|
14
|
Evaluation of the Corrected QT Interval with Bazett’s Method in Cavalier King Charles Spaniel Dogs with Myxomatous Mitral Valve Disease. MACEDONIAN VETERINARY REVIEW 2023. [DOI: 10.2478/macvetrev-2023-0014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023] Open
Abstract
Abstract
Myxomatous mitral valve disease (MMVD) is one of the most common heart diseases in dogs. The disease progresses faster in Cavalier King Charles Spaniel (CKCS) dogs and occurs at an earlier age. QT interval length reflects abnormalities in ventricular repolarization which may predispose to the formation of fatal arrhythmias such as torsades de pointes. A fast and accurate assessment is therefore essential. The study aimed to examine the changes in QT duration in MMVD cases of CKCS and to calculate the corrected QT durations with Bazett’s formula in various stages of the disease. The study included 20 CKCS dogs of both genders, various ages and weights, and different stages of MMVD (n=6 in B1 stage, n=6 in B2 stage, and n=8 in C stage), and 5 healthy CKCS which were included in the control group. Clinical, radiological, hematological, biochemical, echocardiographic, and electrocardiographic examinations were performed. The corrected QT interval duration in the MMVD group was longer than the control (p<0.05). However, there was no significant difference between B1, B2, and C. It was concluded that the corrected QT interval can give a significant distinction between healthy and MMVD CKCS dogs.
Collapse
|
15
|
Temporal change in repolarization parameters after surgical correction of valvular heart diseases. J Electrocardiol 2023; 79:46-52. [PMID: 36934492 DOI: 10.1016/j.jelectrocard.2023.02.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 02/06/2023] [Accepted: 02/12/2023] [Indexed: 03/01/2023]
Abstract
BACKGROUND Ventricular tachyarrhythmia is a potentially fatal outcome of cardiac surgery. Abrupt changes in the hemodynamics after surgical correction of valvular heart disease (VHD) can lead to alterations in ventricular repolarization. We compared the difference between temporal changes in repolarization parameters after correction of left-sided VHD. METHODS We retrospectively analyzed the electrograms of patients who underwent surgical correction of isolated VHD between 2006 and 2015 at Asan Medical Center, including mitral stenosis (MS), mitral regurgitation (MR), aortic stenosis (AS), and aortic regurgitation (AR). Ventricular repolarization parameters were measured at pre-specified time intervals after index surgery using a custom-made ECG analysis program. We compared repolarization parameters, including QT and corrected QT intervals, T peak-to-end interval, and corrected T peak-to-end interval. RESULTS Analysis of 8265 ECGs from 2110 patients (266 MS, 1059 MR, 421 AS, and 364 AR) was performed. Patients with AS were characterized by older age and more comorbidities than other VHDs. The corrected QT interval showed a peak value immediately after surgery and decreased thereafter in the AS groups. However, a gradual increase over 1 month after surgery in AR, MS, and MR groups was observed. The corrected T peak-to-end interval increased in the MS and MR groups and was unchanged in the AS and AR groups. CONCLUSIONS The repolarization parameters of surgery changed dynamically after left-sided valvular surgery. Understanding differential temporal change of repolarization parameters according to the type of VHD would help clinicians avoid fatal arrhythmias related to the repolarization changes.
Collapse
|
16
|
Concentration QTc analysis of giredestrant: Overcoming QT/heart rate confounding in the presence of drug-induced heart rate changes. Clin Transl Sci 2023; 16:823-834. [PMID: 36772881 PMCID: PMC10175970 DOI: 10.1111/cts.13491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 01/13/2023] [Accepted: 01/17/2023] [Indexed: 02/12/2023] Open
Abstract
Concentration-QTc (C-QTc) analysis has become a common approach for evaluating proarrhythmic risk and delayed cardiac repolarization of oncology drug candidates. Significant heart rate (HR) change has been associated with certain classes of oncology drugs and can result in over- or underestimation of the true QT prolongation risk. Because oncology early clinical trials typically lack a placebo control arm or time-matched, treatment-free baseline electrocardiogram collection, significant HR change brings additional challenges to C-QTc analysis in the oncology setting. In this work, a spline-based correction method (QTcSPL) was explored to mitigate the impact of HR changes in giredestrant C-QTc analysis. Giredestrant is a selective estrogen receptor degrader being developed for the treatment of patients with estrogen receptor-positive (ER+) breast cancer. A dose-related HR decrease has been observed in patients under giredestrant treatment, with significant reductions (>10 bpm) observed at supratherapeutic doses. The QTcSPL method demonstrated superior functionality to reduce the correlation between QTc and HR as compared with the Fridericia correction (QTcF). The effect of giredestrant exposure on QTc was evaluated at the clinical dose of 30 mg and supratherapeutic dose of 100 mg based on a prespecified linear mixed effect model. The upper 90% confidence interval of ΔQTcSPL and ΔQTcF were below the 10 ms at both clinical and supratherapeutic exposures, suggesting giredestrant has a low risk of QT prolongation at clinically relevant concentrations. This work demonstrated the use case of QTcSPL to address HR confounding challenges in the context of oncology drug development for the first time.
Collapse
|
17
|
Comparison of formulae for calculating the corrected QT (QTc) interval in an adult population attending a diabetes clinic at a rural hospital in South Africa. JOURNAL OF ENDOCRINOLOGY, METABOLISM AND DIABETES OF SOUTH AFRICA 2023. [DOI: 10.1080/16089677.2022.2151175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
|
18
|
Development of an AI-Driven QT Correction Algorithm for Patients in Atrial Fibrillation. JACC Clin Electrophysiol 2023; 9:246-254. [PMID: 36858692 DOI: 10.1016/j.jacep.2022.09.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 08/12/2022] [Accepted: 09/17/2022] [Indexed: 12/05/2022]
Abstract
BACKGROUND Prolongation of the QTc interval is associated with the risk of torsades de pointes. Determination of the QTc interval is therefore of critical importance. There is no reliable method for measuring or correcting the QT interval in atrial fibrillation (AF). OBJECTIVES The authors sought to evaluate the use of a convolutional neural network (CNN) applied to AF electrocardiograms (ECGs) for accurately estimating the QTc interval and ruling out prolongation of the QTc interval. METHODS The authors identified patients with a 12-lead ECG in AF within 10 days of a sinus ECG, with similar (±10 ms) QRS durations, between October 23, 2001, and November 5, 2021. A multilayered deep CNN was implemented in TensorFlow 2.5 (Google) to predict the MUSE (GE Healthcare) software-generated sinus QTc value from an AF ECG waveform, demographic characteristics, and software-generated features. RESULTS The study identified 6,432 patients (44% female) with an average age of 71 years. The CNN predicted sinus QTc values with a mean absolute error of 22.2 ms and root mean squared error of 30.6 ms, similar to the intrinsic variability of the sinus QTc interval. Approximately 84% and 97% of the model's predictions were contained within 1 SD (±30.6 ms) and 2 SD (±61.2 ms) from the sinus QTc interval. The model outperformed the AFQTc method, exhibiting narrower error ranges (mean absolute error comparison P < 0.0001). The model performed best for ruling out QTc prolongation (negative predictive value 0.82 male, 0.92 female; specificity 0.92 male, 0.97 female). CONCLUSIONS A CNN model applied to AF ECGs accurately predicted the sinus QTc interval, outperforming current alternatives and exhibiting a high negative predictive value.
Collapse
|
19
|
Exercise-related hypoglycaemia induces QTc-interval prolongation in individuals with type 1 diabetes. Diabetes Obes Metab 2023; 25:1186-1195. [PMID: 36593718 DOI: 10.1111/dom.14964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 12/20/2022] [Accepted: 12/30/2022] [Indexed: 01/04/2023]
Abstract
AIMS To investigate changes in cardiac repolarisation during exercise-related hypoglycaemia compared to hypoglycaemia induced at rest in people with type 1 diabetes. MATERIAL AND METHODS In a randomised crossover study, 15 men with type 1 diabetes underwent two separate hyperinsulinaemic euglycaemic-hypoglycaemic clamp experiments during Holter-ECG monitoring. One experiment included a bout of moderate-intensity cycling exercise (60 min) along with declining plasma glucose (PG; Clamp-exercise). In the other experiment, hypoglycaemia was induced with the participants at rest (Clamp-rest). We studied QTc interval, T-peak to T-end (Tpe) interval and hormonal responses during three steady-state phases: (i) baseline (PG 4.0-8.0 mmol/L); (ii) hypoglycaemic phase (PG <3.0 mmol/L); and (iii) recovery phase (PG 4.0-8.0 mmol/L). RESULTS Both QTc interval and Tpe interval increased significantly from baseline during the hypoglycaemic phase but with no significant difference between test days. These changes were accompanied by an increase in plasma adrenaline and a decrease in plasma potassium on both days. During the recovery phase, ΔQTc interval was longer during Clamp-rest compared to Clamp-exercise, whereas ΔTpe interval remained similar on the two test days. CONCLUSIONS We found that both exercise-related hypoglycaemia and hypoglycaemia induced at rest can cause QTc-interval prolongation and Tpe-interval prolongation in people with type 1 diabetes. Thus, both scenarios may increase susceptibility to ventricular arrhythmias.
Collapse
|
20
|
QT Prolongation and In-Hospital Ventricular Arrhythmic Complications in Patients With Apical Ballooning Takotsubo Syndrome. JACC Clin Electrophysiol 2022; 8:1500-1510. [PMID: 36543499 DOI: 10.1016/j.jacep.2022.08.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 08/03/2022] [Accepted: 08/10/2022] [Indexed: 01/18/2023]
Abstract
BACKGROUND Takotsubo syndrome is associated with life threatening arrhythmias, and the apical ballooning pattern is characterized by a peculiar QT prolongation and particularly high-risk of arrhythmias. OBJECTIVES The aim of the study was to determine the association of QT interval on electrocardiogram for ventricular arrhythmic complications in patients with apical ballooning Takotsubo syndrome in a diverse population at a large urban hospital in the U.S. METHODS We reviewed 105 cases of apical ballooning Takotsubo syndrome in patients admitted between 2011 and 2017. Two cardiologists reviewed the electrocardiograms to measure QT interval, adjusted for rate using the Fridericia formula (QTCF), and ventricular arrhythmic complications during the hospitalization. Data are reported as median and interquartile range or number and percentage. RESULTS Of the 105 patients, 86 (82%) were female, and 34 (32%) were self-reported Black or African American. The mean age was 65 years (range: 58-72 years). Left ventricular ejection fraction was 25% (range: 25%-35%). Heart rate was 101 beats/min (range: 83-121 beats/min). Ten (11%) patients experienced a ventricular arrhythmic complication and had significantly longer QTCF (470 [range: 422-543] milliseconds) than did those without complications (417 [range: 383-456] milliseconds, P = 0.031). The area under the curve for QTCF was 0.708 (95% CI: 0.536-0.880; P = 0.031). Twenty-eight (27%) patients had a QTCF ≥460 milliseconds and significantly more arrhythmic complications (21% vs 5%, odds ratio 4.997 [95% CI: 1.288-19.237], P = 0.021). QTCF was an independent predictor of ventricular arrhythmias: odds ratio 1.090 for each 10-millisecond increase in QTCF (95% CI: 1.004-1.183; P = 0.040, corrected for sex). CONCLUSIONS In a diverse population of patients with apical ballooning Takotsubo syndrome admitted to a large urban hospital in the United States, QTCF at admission ≥460 milliseconds identifies patients at high risk for in-hospital arrhythmic complications. Further studies are needed to determine strategies aimed at shortening QT interval to potentially prevent life-threatening arrhythmic events.
Collapse
|
21
|
Accurate QT correction method from transfer entropy. CARDIOVASCULAR DIGITAL HEALTH JOURNAL 2022; 4:1-8. [PMID: 36865582 PMCID: PMC9972000 DOI: 10.1016/j.cvdhj.2022.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
Background The QT interval in the electrocardiogram (ECG) is a fundamental risk measure for arrhythmic adverse cardiac events. However, the QT interval depends on the heart rate and must be corrected accordingly. The present QT correction (QTc) methods are either simple models leading to under- or overcorrection, or impractical in requiring long-term empirical data. In general, there is no consensus on the best QTc method. Objective We introduce a model-free QTc method-AccuQT-that computes QTc by minimizing the information transfer from R-R to QT intervals. The objective is to establish and validate a QTc method that provides superior stability and reliability without models or empirical data. Methods We tested AccuQT against the most commonly used QT correction methods by using long-term ECG recordings of more than 200 healthy subjects from PhysioNet and THEW databases. Results AccuQT overperforms the previously reported correction methods: the proportion of false-positives is reduced from 16% (Bazett) to 3% (AccuQT) for the PhysioNet data. In particular, the QTc variance is significantly reduced and thus the RR-QT stability is increased. Conclusion AccuQT has significant potential to become the QTc method of choice in clinical studies and drug development. The method can be implemented in any device recording R-R and QT intervals.
Collapse
|
22
|
Association of QTc Formula With the Clinical Management of Patients With Cancer. JAMA Oncol 2022; 8:1616-1623. [PMID: 36136321 PMCID: PMC9501778 DOI: 10.1001/jamaoncol.2022.4194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 07/14/2022] [Indexed: 11/14/2022]
Abstract
Importance Monitoring of the corrected QT interval (QTc) for patients with cancer receiving chemotherapy is not standardized. Selection of QTc formula may be associated with adverse event grading and chemotherapy delivery. Objective To describe the association of QTc formula selection with adverse event grading and chemotherapy delivery. Design, Setting, and Participants This retrospective observational cohort study used data from January 2010 to April 2020 and included adult patients seen at the University of North Carolina Cancer Hospital who had an electrocardiogram (ECG) performed. Exposures Adjusted QTc using the Bazett, Fridericia, and Framingham formulae. Main Outcomes and Measures The main outcome was QTc prolongation using the Common Terminology Criteria for Adverse Events (CTCAE). Consistency between formulae was evaluated. Subsequently, appropriateness of clinical management due to prolonged QTc was assessed for a subset of patients being treated with chemotherapy agents associated with a prolonged QT interval. We hypothesized that use of the Bazett formula would be associated with higher rates of QTc prolongation and inappropriate modifications to chemotherapy. Results A total of 19 955 ECGs from 6881 adult patients (3055 [44.4%] women, 3826 [55.6%] men; median [IQR] age at first ECG, 60 [47-68] years) were analyzed. The percentage of ECGs with grade 3 QTc prolongation differed by formula (all patients: Framingham, 1.8%; Fridericia, 2.8%; and Bazett, 9.0%; patients receiving QT-prolonging chemotherapy [2340 ECGs]: Framingham, 2.7%; Fridericia, 4.5%; and Bazett, 12.5%). The Bazett formula resulted in a median QTc value 26.4 milliseconds higher than Fridericia and 27.8 milliseconds higher than Framingham. Of the 1786 ECGs classified as grade 3 by Bazett, 1446 (81.0%) were grade 2 or less by either Fridericia or Framingham. A total of 5 of 28 (17.9%) evaluated clinical changes associated with prolonged QTc were deemed inappropriate when using either Fridericia or Framingham formula. Conclusions and Relevance Findings of this cohort study suggest that the Bazett formula resulted in higher QTc values associated with a 3-fold increase in grade 3 CTCAE toxic effects compared with other common formulae. Use of the Bazett formula likely was associated with inappropriate changes in clinical management. These data support the use of a standard QTc formula (such as Fridericia or Framingham) for QTc correction in oncology.
Collapse
|
23
|
Analysis of athlete QT intervals by age: Fridericia and Hodges heart rate corrections outperform Bazett for athlete ECG screening. J Electrocardiol 2022; 74:59-64. [PMID: 36027674 DOI: 10.1016/j.jelectrocard.2022.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 07/27/2022] [Accepted: 08/11/2022] [Indexed: 12/13/2022]
Abstract
BACKGROUND Cardiac screening of elite athletes including a 12‑lead electrocardiogram (ECG) is recommended by numerous international bodies. Current athlete ECG interpretation guidelines recommend the Bazett method to correct the QT interval (QTc). OBJECTIVE This study sought to investigate normative QTc changes by age using athlete screening ECGs and different QT correction methods in a population of elite cricketers. METHODS Initial cardiac screening ECGs from an existing database of elite Australian cricketers aged 14-35 years were examined. Average QT interval, QTcB (corrected QT-Bazett), QTcF (Fridericia), QTcH (Hodges), and heart rate (HR) were analyzed by age and sex. RESULTS A total of 1310 athletes (66% male, 34% female) were included with mean age 19.1 years and mean heart rate 66.9 bpm (range 38-121 bpm). With increasing age, HR decreased and absolute QT increased. The pattern of QTc change with age differed depending on the method of correction: Bazett correction (QTcB) demonstrated a "dish-shaped" or broad U-shaped appearance; while Fridericia and Hodges corrections showed a linear increase in QTc from young to older age. The Bazett method had a stronger correlation of HR with QTc (R2 = 0.32) than either Fridericia (R2 = 0.0007) or Hodges (R2 = 0.009) methods. CONCLUSIONS The Bazett method is not the most accurate QT correction in athletes, especially during adolescence. In elite cricketers, QTcB revealed a drop in QTc from adolescence to early adulthood due to mis-correction of the QT interval. The Fridericia method has the smoothest correction of HR and least QT variation by age and may be preferred for athlete screening.
Collapse
|
24
|
QT Ratio: A simple solution to individual QT correction. J Pharmacol Toxicol Methods 2022; 117:107211. [PMID: 36007862 DOI: 10.1016/j.vascn.2022.107211] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 08/14/2022] [Accepted: 08/18/2022] [Indexed: 01/10/2023]
Abstract
Preclinical risk assessment of drug-induced arrhythmias is critical for drug development and relies on heart rate corrected QT interval (QT) prolongation as a biomarker for arrhythmia risk. However, the methods used to correct QT vary in complexity and don't account for all changes in the QT-rate relationship. Thus, we developed the novel Ratio QT correction method which characterizes that relationship at each timepoint using the ratio between QT, adjusted for a species-specific constant, and rate (RR interval). This ratio represents the slope between the intercept and the datapoint being corrected, which is then used in a linear equation like individual methods. A unique correction coefficient for each datapoint avoids assuming static relationships. We hypothesize that the simple and dynamic nature of the Ratio method will provide more consistent rate correction and error reduction compared to Bazett's and individual regression methods. Comparisons were made using ECG data from non-human primates (NHPs) treated with dofetilide or moxifloxacin, separated into small groups (n = 4). The methods were compared based on corrected QT vs RR slopes, standard error, and minimal detectable difference (MDD) for each method. The Ratio method resulted in smaller corrected QT-rate relationship slopes than Bazett's, more closely matching those of individual methods. It produced similar or lower MDDs compared to individual and Bazett's correction, respectively, with more consistent reduction in standard error. This simple and effective method has the potential for easy translatability across species.
Collapse
|
25
|
QT interval extracted from 30-minute short resting Holter ECG recordings predicts mortality in heart failure. J Electrocardiol 2022; 72:109-114. [DOI: 10.1016/j.jelectrocard.2022.03.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 03/07/2022] [Accepted: 03/30/2022] [Indexed: 01/08/2023]
|
26
|
Reply to Knuijver et al. on the 'Safety of ibogaine administration in detoxification of opioid-dependent individuals: a descriptive open-label observational study'. Addiction 2022; 117:835-836. [PMID: 34542215 DOI: 10.1111/add.15694] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Accepted: 09/08/2021] [Indexed: 11/28/2022]
|
27
|
Prolonged QT Interval Predicts All-Cause Mortality in Epilepsy Patients: Diagnostic and Therapeutic Implications. Heart Rhythm 2022; 19:585-587. [PMID: 35033664 DOI: 10.1016/j.hrthm.2022.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 01/11/2022] [Accepted: 01/11/2022] [Indexed: 11/29/2022]
|
28
|
Exposure-safety analysis of QTc interval and transaminase levels following bedaquiline administration in patients with drug-resistant tuberculosis. CPT-PHARMACOMETRICS & SYSTEMS PHARMACOLOGY 2021; 10:1538-1549. [PMID: 34626526 PMCID: PMC8674006 DOI: 10.1002/psp4.12722] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/02/2021] [Accepted: 09/15/2021] [Indexed: 11/10/2022]
Abstract
Bedaquiline (BDQ) has shown great value in the treatment of multidrug‐resistant tuberculosis (MDR‐TB) in recent years. However, exposure–safety relationships must be explored to extend the use of BDQ. Two reported safety findings for BDQ are prolongation of the QTc interval and elevation of transaminase levels. In this study, we investigated the potential relationships between BDQ and/or its main metabolite (M2) pharmacokinetic (PK) metrics and QTcF interval or transaminase levels in patients with MDR‐TB using the approved dose regimen. Data from 429 patients with MDR‐TB from two phase IIb studies were analyzed via nonlinear mixed‐effects modeling. Individual model‐predicted concentrations and summary PK metrics were evaluated, respectively, in the QTcF interval and transaminase level exposure–response models. Investigation of further covariate effects was performed in both models. M2 concentrations were found to be responsible for the drug‐related QTcF increase in a model accounting for circadian rhythm patterns, time on study, effect of concomitant medication with QT liability, and patient demographics. Simulations with the final model suggested that doses higher than the approved dose (leading to increased M2 concentrations) are not expected to lead to a critical QTcF interval increase. No exposure–safety relationship could be described with transaminase levels despite previous reports of higher levels in patients treated with BDQ. The developed longitudinal models characterized the role of M2 concentrations in QTc interval prolongation and found no concentration dependency for transaminase level elevation, together suggesting that BDQ exposure at the high end of the observed range may not be associated with a higher risk of safety events.
Collapse
|