1
|
Chen Z, Wang Y. A label- and enzyme-free fluorescence assay based on thioflavin T–induced G-quadruplexes for the detection of telomerase activity. JOURNAL OF CHEMICAL RESEARCH 2023. [DOI: 10.1177/17475198221139085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
A label- and enzyme-free fluorescence assay based on thioflavin T–induced G-quadruplexes is developed to sensitively and specifically detect telomerase activity. Thioflavin T has a dual role as an efficient inducer and fluorescent probe, and the incorporation of thioflavin T into the thioflavin T–induced G-quadruplexes results in an intense fluorescence enhancement. In the presence of thioflavin T and K+, G-quadruplexes are formed by elongation of the telomerase substrate primer that is catalyzed by telomerase extracted from cancer cells. Thus, the telomerase activity in cancer cell extracts can be evaluated by measuring the thioflavin T fluorescence. More importantly, thioflavin T can specifically recognize and bind to G-quadruplexes, whereas it cannot recognize single- and double-stranded DNAs, which leads to the thioflavin T–based fluorescence assay exhibiting a reduced background and improved signal-to-noise ratio. As a result, the proposed assay has the linear range from 5 to 200 HeLa cells and the detection limit is 34 HeLa cells, which holds great potential for use in the detection of telomerase activity and the diagnosis of cancer.
Collapse
Affiliation(s)
- Zhe Chen
- School of Forensic Medicine, Shanxi Medical University, Jinzhong, P.R. China
- Key Laboratory of Forensic Toxicology of Ministry of Public Security, Jinzhong, P.R. China
| | - Yunxia Wang
- Department of Laboratory Science, Shanxi Medical University, Taiyuan, P.R. China
- The Sixth Hospital of Shanxi Medical University (General Hospital of Tisco), Taiyuan, P.R. China
| |
Collapse
|
2
|
Zhang S, Li S, Yan R, Zhou Z, Wu Y, Lu Y. Recent advances of using personal glucose meter as a biosensor readout for non-glucose targets. CURR ANAL CHEM 2021; 18:705-722. [PMID: 37811138 PMCID: PMC10557464 DOI: 10.2174/1573411017666210804105750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 05/06/2021] [Accepted: 05/25/2021] [Indexed: 11/22/2022]
Abstract
Background Personal glucose meter (PGM) has become the most successful biosensor in past decades due to its advantages of small size, convenient operation, and low cost. To take advantage of many years of research and development of PGMs, new signal transduction methods has been developed to expand the PGM from simple monitoring blood glucose to detection of numerous non-glucose targets. Objectives This review summarizes recent advance of PGM-based biosensors for non-glucose targets including signal transduction, signal amplification and target molecule recognition and analysis. Current challenges and future directions are also discussed. Conclusion PGM can be used as biosensor readout to detect various non-glucose targets from metal ion, small molecule to protein and even living organisms such as bacteria and other pathogens by using different signal transduction elements such as invertase and amylase, and different signal amplification methods such as nanomaterials, nucleic acid reaction, liposome encapsulation, hydrogel trapping, DNAzyme amplification and biotin-streptavidin reaction.
Collapse
Affiliation(s)
- Songbai Zhang
- Hunan Provincial Key Laboratory of Water Treatment Functional Materials, Hunan Province Engineering Research Center of Electroplating Wastewater Reuse Technology, Hunan Province Cooperative Innovation Center for The Construction & Development of Dongting Lake Ecological Economic Zone, College of Chemistry and Materials Engineering, Hunan University of Arts and Science, Changde 415000, P. R. China
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Shuang Li
- Hunan Provincial Key Laboratory of Water Treatment Functional Materials, Hunan Province Engineering Research Center of Electroplating Wastewater Reuse Technology, Hunan Province Cooperative Innovation Center for The Construction & Development of Dongting Lake Ecological Economic Zone, College of Chemistry and Materials Engineering, Hunan University of Arts and Science, Changde 415000, P. R. China
| | - Rixin Yan
- Hunan Provincial Key Laboratory of Water Treatment Functional Materials, Hunan Province Engineering Research Center of Electroplating Wastewater Reuse Technology, Hunan Province Cooperative Innovation Center for The Construction & Development of Dongting Lake Ecological Economic Zone, College of Chemistry and Materials Engineering, Hunan University of Arts and Science, Changde 415000, P. R. China
| | - Zhiyun Zhou
- Hunan Provincial Key Laboratory of Water Treatment Functional Materials, Hunan Province Engineering Research Center of Electroplating Wastewater Reuse Technology, Hunan Province Cooperative Innovation Center for The Construction & Development of Dongting Lake Ecological Economic Zone, College of Chemistry and Materials Engineering, Hunan University of Arts and Science, Changde 415000, P. R. China
| | - Yuting Wu
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Yi Lu
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
3
|
Wang D, Xue W, Ren X, Xu Z. A review on sensing mechanisms and strategies for telomerase activity detection. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2020.116115] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
4
|
Kim HY, Lee CY, Kim H, Park KS, Park HG. Portable glucose meter-utilized label-free and washing-free telomerase assay. Analyst 2020; 145:5578-5583. [PMID: 32627768 DOI: 10.1039/d0an00655f] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
We herein describe a portable glucose meter (PGM)-utilized label-free and washing-free method for the facile determination of telomerase activity that relies on the kinase-catalyzed cascade enzymatic reaction (KCER) that transduces the telomerase activity to the glucose level. In the sensor, the telomerase that elongates telomere sequences ((TTAGGG)n) from the 3'-terminus of telomerase substrate primer (TSP) consumes deoxynucleoside triphosphate (dNTP), which serves as a phosphate source for KCER promoted by hexokinase and pyruvate kinase. Thus, the presence of telomerase protects KCER from working effectively, resulting in the maintenance of an initial, high glucose level that is readily determined using hand-held PGM. With this strategy, the telomerase activities in various types of cell lines were successfully determined with high sensitivity. Furthermore, the ability of this method to screen candidate inhibitors for telomerase activity was also verified.
Collapse
Affiliation(s)
- Hyo Yong Kim
- Department of Chemical and Biomolecular Engineering (BK21+ Program), KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
| | | | | | | | | |
Collapse
|
5
|
Zhang J, Lan T, Lu Y. Translating in vitro diagnostics from centralized laboratories to point-of-care locations using commercially-available handheld meters. Trends Analyt Chem 2020; 124:115782. [PMID: 32194293 PMCID: PMC7081941 DOI: 10.1016/j.trac.2019.115782] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
There is a growing demand for high-performance point-of-care (POC) diagnostic technologies where in vitro diagnostics (IVD) is fundamental for prevention, identification, and treatment of many diseases. Over the past decade, a shift of IVDs from the centralized laboratories to POC settings is emerging. In this review, we summarize recent progress in translating IVDs from centralized labs to POC settings using commercially available handheld meters. After introducing typical workflows for IVDs and highlight innovative technologies in this area, we discuss advantages of using commercially available handheld meters for translating IVDs from centralized labs to POC settings. We then provide comprehensive coverage of different signal transduction strategies to repurpose the commercially-available handheld meters, including personal glucose meter, pH meter, thermometer and pressure meter, for detecting a wide range of targets by integrating biochemical assays with the meters for POC testing. Finally, we identify remaining challenges and offer future outlook in this area.
Collapse
Affiliation(s)
- JingJing Zhang
- State Key Laboratory of Analytical Chemistry for Life
Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing
210023, China
| | - Tian Lan
- GlucoSentient, Inc., 2100 S. Oak Street, Suite 101,
Champaign, IL 61820, USA
| | - Yi Lu
- Department of Chemistry, University of Illinois at
Urbana–Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
6
|
Lisi F, Peterson JR, Gooding JJ. The application of personal glucose meters as universal point-of-care diagnostic tools. Biosens Bioelectron 2020; 148:111835. [DOI: 10.1016/j.bios.2019.111835] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 10/28/2019] [Accepted: 10/30/2019] [Indexed: 02/06/2023]
|
7
|
Abrosimova LA, Kisil OV, Romanova EA, Oretskaya TS, Kubareva EA. Nicking Endonucleases as Unique Tools for Biotechnology and Gene Engineering. RUSSIAN JOURNAL OF BIOORGANIC CHEMISTRY 2019. [DOI: 10.1134/s1068162019050017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
8
|
Díaz-Cartagena D, Hernández-Cancel G, Bracho-Rincón DP, González-Feliciano JA, Cunci L, González CI, Cabrera CR. Label-Free Telomerase Activity Detection via Electrochemical Impedance Spectroscopy. ACS OMEGA 2019; 4:16724-16732. [PMID: 31646217 PMCID: PMC6796945 DOI: 10.1021/acsomega.9b00783] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Accepted: 05/16/2019] [Indexed: 05/14/2023]
Abstract
In the last decade, researchers have been searching for innovative platforms, methods, and techniques able to address recurring problems with the current cancer detection methods. Early disease detection, fast results, point-of-care sensing, and cost are among the most prevalent issues that need further exploration in this field. Herein, studies are focused on overcoming these problems by developing an electrochemical device able to detect telomerase as a cancer biomarker. Electrochemical platforms and techniques are more appealing for cancer detection, offering lower costs than the established cancer detection methods, high sensitivity inherent to the technique, rapid signal processing, and their capacity of being miniaturized. Therefore, Au interdigital electrodes and electrochemical impedance spectroscopy were used to detect telomerase activity in acute T cell leukemia. Different cancer cell concentrations were evaluated, and a detection limit of 1.9 × 105 cells/mL was obtained. X-ray photoelectron spectroscopy was used to characterize the telomerase substrate (TS) DNA probe self-assembled monolayer on gold electrode surfaces. Atomic force microscopy displayed three-dimensional images of the surface to establish a height difference of 9.0 nm between the bare electrode and TS-modified Au electrodes. The TS probe is rich in guanines, thus forming secondary structures known as G-quadruplex that can be triggered with a fluorescence probe. Confocal microscopy fluorescence images showed the formation of DNA G-quadruplex because of TS elongation by telomerase on the Au electrode surface. Moreover, electrodes exposed to telomerase containing 2',3'-dideoxyguanosine-5'-triphosphate (ddGTP) did not exhibit high fluorescence, as ddGTP is a telomerase inhibitor, thus making this device suitable for telomerase inhibitors capacity studies. The electrochemical method and Au microchip device may be developed as a biosensor for a point-of-care medical device.
Collapse
Affiliation(s)
- Diana
C. Díaz-Cartagena
- Department
of Chemistry, University of Puerto Rico, Río Piedras Campus, San Juan, Puerto Rico 00925-2537, United States
- Molecular
Sciences Research Center, University of
Puerto Rico, San Juan, Puerto Rico 00926, United States
| | - Griselle Hernández-Cancel
- Molecular
Sciences Research Center, University of
Puerto Rico, San Juan, Puerto Rico 00926, United States
| | - Dina P. Bracho-Rincón
- Molecular
Sciences Research Center, University of
Puerto Rico, San Juan, Puerto Rico 00926, United States
- Department
of Biology, University of Puerto Rico, Río Piedras Campus, San Juan, Puerto Rico 00931, United States
| | - José A. González-Feliciano
- Molecular
Sciences Research Center, University of
Puerto Rico, San Juan, Puerto Rico 00926, United States
| | - Lisandro Cunci
- School
of Natural Sciences and Technology, Universidad
Ana G. Méndez, Gurabo Campus, Gurabo, Puerto
Rico 00778, United
States
| | - Carlos I. González
- Molecular
Sciences Research Center, University of
Puerto Rico, San Juan, Puerto Rico 00926, United States
- Department
of Biology, University of Puerto Rico, Río Piedras Campus, San Juan, Puerto Rico 00931, United States
| | - Carlos R. Cabrera
- Department
of Chemistry, University of Puerto Rico, Río Piedras Campus, San Juan, Puerto Rico 00925-2537, United States
- Molecular
Sciences Research Center, University of
Puerto Rico, San Juan, Puerto Rico 00926, United States
- E-mail:
| |
Collapse
|
9
|
Portable detection of colorectal cancer SW620 cells by using a personal glucose meter. Anal Biochem 2019; 577:110-116. [PMID: 31034799 DOI: 10.1016/j.ab.2019.04.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 04/22/2019] [Accepted: 04/22/2019] [Indexed: 12/22/2022]
Abstract
It is of great value to develop general, low-cost and even household methods for colorectal cancer detection. Here, a portable detection strategy based on a personal glucose meter (PGM) was designed for meeting this purpose. In this strategy, the anti-EpCAM coated magnet beads (MBs) were used as capture probes for enriching cancer cells and the aptamer modified and invertase loaded graphene oxides (GO) were used as report probes for producing glucose signal. This method is sensitive with detection limit as low as 560 cells, and demonstrates excellent detection specificity. Meanwhile, we succeeded in the specific detection of target cells in 20% human serum samples, indicating this method has great prospect in clinical diagnosis. Moreover, this method presents favourable universality for detecting different colorectal cancer cells by just using different recognition aptamers. Importantly, this method can be implemented for the target cell detection at room temperature without any expensive and large-scale instruments but a portable PGM. Therefore, this portable detection method possesses great potential in point-of-care detection of colorectal cancer cells.
Collapse
|
10
|
Liu C, Zhang S, Li X, Xue Q, Jiang W. Multi-code magnetic beads based on DNAzyme-mediated double-cycling amplification for a point-of-care assay of telomerase activity. Analyst 2019; 144:4241-4249. [DOI: 10.1039/c9an00589g] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Development of a reliable and facile telomerase activity assay with high specificity and sensitivity is a central challenge to make telomerase testing a routine part of medical care with respect to cancer.
Collapse
Affiliation(s)
- Chunxue Liu
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
| | - Susu Zhang
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
| | - Xia Li
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
- School of Chemistry and Chemical Engineering
| | - Qingwang Xue
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
- School of Chemistry and Chemical Engineering
| | - Wei Jiang
- School of Chemistry and Chemical Engineering
- Shandong University
- Jinan 250100
- P.R. China
| |
Collapse
|
11
|
Zhang L, Gu C, Ma H, Zhu L, Wen J, Xu H, Liu H, Li L. Portable glucose meter: trends in techniques and its potential application in analysis. Anal Bioanal Chem 2018; 411:21-36. [DOI: 10.1007/s00216-018-1361-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 08/07/2018] [Accepted: 09/04/2018] [Indexed: 12/18/2022]
|
12
|
Meng F, Xu Y, Dong W, Tang Y, Miao P. A PCR-free voltammetric telomerase activity assay using a substrate primer on a gold electrode and DNA-triggered capture of gold nanoparticles. Mikrochim Acta 2018; 185:398. [PMID: 30069792 DOI: 10.1007/s00604-018-2936-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Accepted: 07/24/2018] [Indexed: 01/08/2023]
Abstract
The paper describes a voltammetric method for the quantitation of the activity of telomerase extracted from cancer cells. A thiolated single-stranded telomerase substrate primer was firstly immobilized on a gold electrode. In the presence of a mixture of telomerase and deoxynucleotide triphosphates, the primer becomes elongated and contains repetitive nucleotide sequences (TTAGGG)n. After hybridization with blocker DNA, gold nanoparticles are added and captured by the elongated single-stranded DNA. This reduces the charge transfer resistance of the gold electrode. The telomerase activity is then quantified via differential pulse voltammetry, typically at 0.12 V (vs. SCE). The method is PCR-free, rapid, and convenient. It was applied to the detection of HeLa cells via the telomerase activity of lysed cells. The detection range was from 500 to 50,000 cells/mL and the detection limit was as low as 500 cells/mL. Graphical abstract A telomerase substrate (TS) primer is immobilized on a gold electrode as the sensing interface to detect the activity of telomerase extracted from cancer cells. Unmodified gold nanoparticles (AuNPs) are utilized which change the electrochemical responses.
Collapse
Affiliation(s)
- Fanyu Meng
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, People's Republic of China.,University of Science and Technology of China, Hefei, 230026, People's Republic of China
| | - Yuanyuan Xu
- Key Laboratory of Animal Physiology and Biochemistry, College of Veterinary Medicine, Nanjing Agricultural University, Nanjing, 210095, People's Republic of China
| | - Wenfei Dong
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, People's Republic of China
| | - Yuguo Tang
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, People's Republic of China
| | - Peng Miao
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, People's Republic of China. .,University of Science and Technology of China, Hefei, 230026, People's Republic of China.
| |
Collapse
|
13
|
Huang S, Yao H, Wang W, Zhang JR, Zhu JJ. Highly sensitive fluorescence quantification of intracellular telomerase activity by repeat G-rich DNA enhanced silver nanoclusters. J Mater Chem B 2018; 6:4583-4591. [DOI: 10.1039/c8tb00801a] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
As an important biomarker for early cancer diagnosis and a valuable therapeutic target, the detection and monitoring of telomerase activity has attracted extensive attention.
Collapse
Affiliation(s)
- Shan Huang
- State Key Laboratory of Analytical Chemistry for Life Science
- School of Chemistry and Chemical Engineering
- Nanjing University
- Nanjing
- China
| | - Huiqin Yao
- Department of Chemistry
- School of Basic Medical Sciences
- Ningxia Medical University
- Yinchuan
- China
| | - Wenjing Wang
- State Key Laboratory of Analytical Chemistry for Life Science
- School of Chemistry and Chemical Engineering
- Nanjing University
- Nanjing
- China
| | - Jian-Rong Zhang
- School of Chemistry and Life Science
- Nanjing University Jinling College
- Nanjing 210089
- China
| | - Jun-Jie Zhu
- State Key Laboratory of Analytical Chemistry for Life Science
- School of Chemistry and Chemical Engineering
- Nanjing University
- Nanjing
- China
| |
Collapse
|
14
|
Gao F, Yao Y, Wu J, Cui L, Zhang Y, Geng D, Tang D, Yu Y. A robust fluorescent probe for detection of telomerase activityin vitroand imaging in living cellsviatelomerase-triggering primer extension to desorb DNA from graphene oxide. Analyst 2018; 143:3651-3660. [DOI: 10.1039/c8an00815a] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
A novel strategy for telomerase imaging was developed based on telomerase-triggering primer extension to desorb fluorophore labeled DNA from graphene oxide.
Collapse
Affiliation(s)
- Fenglei Gao
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| | - Yao Yao
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| | - Jing Wu
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| | - Lin Cui
- Chemical Engineering and Materials Science
- Shandong Normal University
- Jinan 250014
- China
| | - Yu Zhang
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| | - Deqin Geng
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| | - Daoquan Tang
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| | - Yanyan Yu
- Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy
- School of Pharmacy
- Xuzhou Medical University
- Xuzhou
- China
| |
Collapse
|
15
|
Su D, Huang X, Dong C, Ren J. Quantitative Determination of Telomerase Activity by Combining Fluorescence Correlation Spectroscopy with Telomerase Repeat Amplification Protocol. Anal Chem 2017; 90:1006-1013. [PMID: 29211436 DOI: 10.1021/acs.analchem.7b04256] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Telomerase is a key enzyme for maintaining the telomere length and is regarded as a versatile cancer biomarker and a potential drug target due to its important role in cancer and aging. It is necessary to develop a sensitive and reliable method for detection of telomerase activity due to its very low level in cells. In this Article, we propose an ultrasensitive and robust method for quantitative determination of telomerase activity by combining single molecule fluorescence correlation spectroscopy (FCS) with telomerase repeat amplification protocol (TRAP). The principle of this new method (FCS-TRAP) is based on measurement of the change in characteristic diffusion time and molecule number of TRAP products by FCS. The characteristic diffusion time is related to the length of TRAP products, and the molecule number represents the concentration of TRAP products. We optimized the conditions of TRAP procedure and FCS measurements. We observed that the telomerase activities are positively correlated to characteristic diffusion time and molecule number of TRAP products at optimal conditions. This method was successfully used for determination of telomerase activity of different cells, and detection of a single cell was realized. Meanwhile, this method was used to evaluate the inhibition efficiency of inhibitors, and the IC50 values obtained were in good agreement with the references. Compared to current TRAP methods, this method shows reliable quantification, ultrahigh sensitivity, and short detection time and is without separation. We believe that the FCS-TRAP method has a potential application in clinical diagnosis and screening of telomerase inhibitors.
Collapse
Affiliation(s)
- Di Su
- School of Chemistry & Chemical Engineering, State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University , 800 Dongchuan Road, Shanghai, 200240, P. R. China
| | - Xiangyi Huang
- School of Chemistry & Chemical Engineering, State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University , 800 Dongchuan Road, Shanghai, 200240, P. R. China
| | - Chaoqing Dong
- School of Chemistry & Chemical Engineering, State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University , 800 Dongchuan Road, Shanghai, 200240, P. R. China
| | - Jicun Ren
- School of Chemistry & Chemical Engineering, State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University , 800 Dongchuan Road, Shanghai, 200240, P. R. China
| |
Collapse
|
16
|
Qiu S, Zhao F, Zenasni O, Li J, Shih WC. Catalytic assembly of DNA nanostructures on a nanoporous gold array as 3D architectures for label-free telomerase activity sensing. NANOSCALE HORIZONS 2017; 2:217-224. [PMID: 32260643 DOI: 10.1039/c7nh00042a] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Telomerase, an enzyme known to catalyze telomere elongation by adding TTAGGG [thymine (T), adenine (A), and guanine (G)] repeats to the end of telomeres, is vital for cell proliferation. Overexpression of telomerase has been found in most tumor cells, resulting in telomere dysfunction and uncontrolled cellular proliferation. Thus, telomerase has been considered as a potential cancer biomarker, as well as a potential target in cancer therapy. In this study, telomerase-catalyzed growth of tandem G-quadruplex (G4) assembled on a nanoporous gold array (NPGA) resulted in the formation of three-dimensional hybrid nanoarchitectures. The generated nanostructure then captured malachite green (MG) (reporter molecule) without the need of a complicated labeling process. Upon laser irradiation, the captured MG molecules produced a surface-enhanced Raman scattering (SERS) signal that was generated by an abundant amount of plasmonic hot spots in the NPGA substrates. A limit of detection (LOD) of 10-10 IU along with a linear range, which was 3 orders of magnitude, was achieved, which was equivalent to the telomerase amount extracted from 20 HeLa cells. The LOD is 2 orders of magnitude better than that of the commercial enzyme-linked immunosorbent assay (ELISA), and it approaches that of the most sensitive technique, telomeric repeat amplification protocols (TRAP), which require a laborious and equipment-intensive polymerase chain reaction (PCR). In addition, X-ray photoelectron spectroscopy (XPS) was used to chemically identify and quantify the telomerase activity on the sensitized NPGA surface. Furthermore, the sensor was applied to screen the effectiveness of anti-telomerase drugs such as zidovudine, thus demonstrating the potential use of the sensor in telomerase-based diagnosis and drug development. Moreover, the framework represents a novel paradigm of collaborative plasmonic intensification and catalytic multiplication (c-PI/CM) for label-free biosensing.
Collapse
Affiliation(s)
- Suyan Qiu
- Department of Electrical and Computer Engineering, University of Houston, 4800 Calhoun Road, Houston, TX 77204, USA.
| | | | | | | | | |
Collapse
|
17
|
Ran B, Xianyu Y, Dong M, Chen Y, Qian Z, Jiang X. Bioorthogonal Reaction-Mediated ELISA Using Peroxide Test Strip as Signal Readout for Point-of-Care Testing. Anal Chem 2017; 89:6113-6119. [PMID: 28460169 DOI: 10.1021/acs.analchem.7b00831] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
This work demonstrates a highly sensitive peroxide test strip (PTS)-based enzyme-linked immunosorbent assay (ELISA) for both qualitative and quantitative detection of drugs of abuse (morphine) and disease biomarkers (interleukin-6 and HIV-1 capsid antigen p24). This color-based PTS is a commercially available product with advantages of low cost, easy operation, and portability, and it is an ideal signal readout strategy in ELISA to simplify the immunoassay procedures and enable point-of-care testing (POCT). In addition, we introduce the bioorthogonal reaction that can effectively amplify the signal by controlling the cycles of bioorthogonal reaction to achieve the desirable sensitivity depending on different analytes. The limit of detection is 0.2 ng/mL for morphine, 3.98 pg/mL for interleukin-6, and 11.6 pg/mL for detection of HIV-capsid antigen (p24). This PTS-ELISA applies to both the qualitative and quantitative detection of IL-6 and p24 in clinical serum samples with good accuracy, which provides a promising tool for the POCT in clinical diagnosis.
Collapse
Affiliation(s)
- Bei Ran
- State Key Laboratory of Biotherapy/Collaborative Innovation Center for Biotherapy, West China Hospital, Sichuan University , Chengdu, 610041, People's Republic of China.,CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology , Beijing 100190, China
| | - Yunlei Xianyu
- CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology , Beijing 100190, China
| | - Mingling Dong
- State Key Laboratory of Biotherapy/Collaborative Innovation Center for Biotherapy, West China Hospital, Sichuan University , Chengdu, 610041, People's Republic of China.,CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology , Beijing 100190, China
| | - Yiping Chen
- CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology , Beijing 100190, China
| | - Zhiyong Qian
- State Key Laboratory of Biotherapy/Collaborative Innovation Center for Biotherapy, West China Hospital, Sichuan University , Chengdu, 610041, People's Republic of China
| | - Xingyu Jiang
- CAS Key Lab for Biological Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology , Beijing 100190, China.,The University of Chinese Academy of Sciences , 19 A Yuquan Road, Shijingshan District, Beijing, 100049, People's Republic of China
| |
Collapse
|
18
|
Abstract
Telomerase plays a significantly important role in keeping the telomere length of a chromosome. Telomerase overexpresses in nearly all tumor cells, suggesting that telomerase could be not only a promising biomarker but also a potential therapeutic target for cancers. Therefore, numerous efforts focusing on the detection of telomerase activity have been reported from polymerase chain reaction (PCR)-based telomeric repeat amplification protocol (TRAP) assays to PCR-free assays such as isothermal amplification in recent decade. In this review, we highlight the strategies for the detection of telomerase activity using isothermal amplification and discuss some of the challenges in designing future telomerase assays as well.
Collapse
|
19
|
Su X, Li Z, Yan X, Wang L, Zhou X, Wei L, Xiao L, Yu C. Telomerase Activity Detection with Amplification-Free Single Molecule Stochastic Binding Assay. Anal Chem 2017; 89:3576-3582. [DOI: 10.1021/acs.analchem.6b04883] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Xin Su
- Beijing
Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Zehao Li
- Beijing
Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Xinzhong Yan
- Beijing
Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Lei Wang
- Beijing
Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Xu Zhou
- Beijing
Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| | - Lin Wei
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Key Laboratory of Phytochemical R&D of Hunan Province, College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, Hunan 410081, China
| | - Lehui Xiao
- Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research, Ministry of Education, Key Laboratory of Phytochemical R&D of Hunan Province, College of Chemistry and Chemical Engineering, Hunan Normal University, Changsha, Hunan 410081, China
- College
of Chemistry, Nankai University, Tianjin 300071, China
| | - Changyuan Yu
- Beijing
Key Laboratory of Bioprocess, College of Life Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
| |
Collapse
|
20
|
Xue Q, Kong Y, Wang H, Jiang W. Liposome-encoded magnetic beads initiated by padlock exponential rolling circle amplification for portable and accurate quantification of microRNAs. Chem Commun (Camb) 2017; 53:10772-10775. [DOI: 10.1039/c7cc05686a] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
In this work, we propose a strategy for glucoamylase-encapsulated liposome-encoded magnetic beads initiated by padlock exponential rolling circle amplification (P-ERCA) for portable and accurate quantification of miRNA by using a glucometer (GM) for readout.
Collapse
Affiliation(s)
- Qingwang Xue
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
| | - Yancong Kong
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
| | - Huaisheng Wang
- Department of Chemistry
- Liaocheng University
- Liaocheng
- China
| | - Wei Jiang
- School of Chemistry and Chemical Engineering
- Shandong University
- Jinan 250100
- P. R. China
| |
Collapse
|
21
|
Zhang J, Shen Z, Xiang Y, Lu Y. Integration of Solution-Based Assays onto Lateral Flow Device for One-Step Quantitative Point-of-Care Diagnostics Using Personal Glucose Meter. ACS Sens 2016. [DOI: 10.1021/acssensors.6b00270] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- JingJing Zhang
- Department
of Chemistry, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
| | - Zhe Shen
- Department
of Chemistry, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
| | - Yu Xiang
- Department
of Chemistry, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
- Department
of Chemistry, Tsinghua University, Beijing 100084, P.R. China
| | - Yi Lu
- Department
of Chemistry, University of Illinois at Urbana−Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|