1
|
A potentiometric sensor for the determination of potassium in different baby follow–on milk, water, juice and pharmaceutical samples. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2022.104937] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
2
|
Salehan P, Ensafi AA, Mousaabadi KZ, Ghasemi JB, Aghaee E, Rezaei B. A theoretical and experimental study of polyaniline/GCE and DNA G-quadruplex conformation as an impedimetric biosensor for the determination of potassium ions. CHEMOSPHERE 2022; 292:133460. [PMID: 34971631 DOI: 10.1016/j.chemosphere.2021.133460] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 12/14/2021] [Accepted: 12/26/2021] [Indexed: 06/14/2023]
Abstract
An electrochemical aptasensor has been developed to determine K+ using electrochemical impedance spectroscopy. The polyaniline (PANI) coating was first electrodeposited on a GCE. Then, the potassium-selective aptamer [G3(T2AG3)3] was adsorbed through an electrostatic force between PANI and aptamer. In the presence of K+, the single-stranded DNA is folded into the G-quadruplex configuration, which acts as a barrier against electron transfer at the GCE surface. AFM and FE-SEM images characterize the surface morphology at each fabrication stage. As the K+ concentration increased, the charge transfer resistance (Rct) increased, and the plot of ΔRct versus the logarithm of the K+ concentration is linear over a wide range of 10 pM-60 μM with a low detection limit of 3.7 pM. Finally, the proposed sensor was used to determine K+ in water, serum, urine, and fruit samples. Moreover, the binding stability of the aptamer/PANI and K+/Aptamer/PANI and the interactions between the aptamer and PANI were analyzed through molecular dynamics simulation.
Collapse
Affiliation(s)
- P Salehan
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
| | - Ali A Ensafi
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran; Adjunct Professor, Department of Chemistry & Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA.
| | - K Zarean Mousaabadi
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
| | - Jahan B Ghasemi
- School of Chemistry, College of Science, University of Tehran, Tehran, Iran.
| | - E Aghaee
- School of Chemistry, College of Science, University of Tehran, Tehran, Iran.
| | - B Rezaei
- Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
| |
Collapse
|
3
|
Li D, Gao D, Qi J, Chai R, Zhan Y, Xing C. Conjugated Polymer/Graphene Oxide Complexes for Photothermal Activation of DNA Unzipping and Binding to Protein. ACS APPLIED BIO MATERIALS 2018. [DOI: 10.1021/acsabm.8b00047] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
4
|
Guo L, Hu Y, Zhang Z, Tang Y. Universal fluorometric aptasensor platform based on water-soluble conjugated polymers/graphene oxide. Anal Bioanal Chem 2017; 410:287-295. [DOI: 10.1007/s00216-017-0720-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 10/17/2017] [Accepted: 10/20/2017] [Indexed: 12/18/2022]
|
5
|
Adachi N, Yoshinari M, Suzuki E, Okada M. Oligo(p-phenylene ethynylene) with Cyanoacrylate Terminal Groups and Graphene Composite as Fluorescent Chemical Sensor for Cysteine. J Fluoresc 2017; 27:1449-1456. [PMID: 28391541 DOI: 10.1007/s10895-017-2084-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Accepted: 04/04/2017] [Indexed: 12/25/2022]
Abstract
A chemical sensor for cysteine (Cys) was fabricated based on a fluorescent oligo(p-phenylene ethynylene)s (OPEs) and OPE-graphene oxide (GO) composite. OPE with cyanoacrylate terminal groups were synthesized by a Pd-catalyzed Sonogashira coupling reaction and Knoevenagel condensation for use as a chemical sensor for Cys. The optical properties and Cys sensing capability of the cyanoacrylate modified OPE and OPE-GO composite were investigated. In addition of Cys, the fluorescence of OPE was blue-shifted and decreased (fluorescence turn-off), while the fluorescence of the OPE-GO composite was enhanced (fluorescence turn-on). Thus, OPE with cyanoacrylate terminal groups and OPE-GO composite acts a highly sensitive fluorescent chemical sensor for Cys.
Collapse
Affiliation(s)
- Naoya Adachi
- Division of Science, School of Science and Engineering, Tokyo Denki University, Hatoyama, Hiki-gun, Saitama, 350-0394, Japan. .,Department of Science and Engineering, Graduate School of Science and Engineering, Tokyo Denki University, Hatoyama, Hiki-gun, Saitama, 350-0394, Japan.
| | - Mariko Yoshinari
- Division of Science, School of Science and Engineering, Tokyo Denki University, Hatoyama, Hiki-gun, Saitama, 350-0394, Japan
| | - Eri Suzuki
- Department of Science and Engineering, Graduate School of Science and Engineering, Tokyo Denki University, Hatoyama, Hiki-gun, Saitama, 350-0394, Japan
| | - Mari Okada
- Department of Science and Engineering, Graduate School of Science and Engineering, Tokyo Denki University, Hatoyama, Hiki-gun, Saitama, 350-0394, Japan
| |
Collapse
|
6
|
Baruah U, Chowdhury D. Functionalized graphene oxide quantum dot-PVA hydrogel: a colorimetric sensor for Fe²⁺, Co²⁺ and Cu²⁺ ions. NANOTECHNOLOGY 2016; 27:145501. [PMID: 26902906 DOI: 10.1088/0957-4484/27/14/145501] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Functionalized graphene oxide quantum dots (GOQDs)-poly(vinyl alcohol) (PVA) hybrid hydrogels were prepared using a simple, facile and cost-effective strategy. GOQDs bearing different surface functional groups were introduced as the cross-linking agent into the PVA matrix thereby resulting in gelation. The four different types of hybrid hydrogels were prepared using graphene oxide, reduced graphene oxide, ester functionalized graphene oxide and amine functionalized GOQDs as cross-linking agents. It was observed that the hybrid hydrogel prepared with amine functionalized GOQDs was the most stable. The potential applicability of using this solid sensing platform has been subsequently explored in an easy, simple, effective and sensitive method for optical detection of M(2+) (Fe(2+), Co(2+) and Cu(2+)) in aqueous media involving colorimetric detection. Amine functionalized GOQDs-PVA hybrid hydrogel when put into the corresponding solution of Fe(2+), Co(2+) and Cu(2+) renders brown, orange and blue coloration respectively of the solution detecting the presence of Fe(2+), Co(2+) and Cu(2+) ions in the solution. The minimum detection limit observed was 1 × 10(-7) M using UV-visible spectroscopy. Further, the applicability of the sensing material was also tested for a mixture of co-existing ions in solution to demonstrate the practical applicability of the system. Insight into the probable mechanistic pathway involved in the detection process is also being discussed.
Collapse
Affiliation(s)
- Upama Baruah
- Material Nanochemistry Laboratory, Physical Sciences Division, Institute of Advanced Study in Science and Technology, Paschim Boragaon, Garchuk, Guwahati-781035, India
| | | |
Collapse
|
7
|
Adachi N, Nakajima M, Okada M, Sugeno M, Norioka T. Fluorescence chemical sensor based on water-soluble poly(p-phenylene ethynylene)-graphene oxide composite for Cu2+. POLYM ADVAN TECHNOL 2015. [DOI: 10.1002/pat.3633] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Naoya Adachi
- Division of Science, School of Science and Engineering; Tokyo Denki University; Hatoyama, Hiki-gun Saitama 350-0394 Japan
| | - Mai Nakajima
- Division of Science, School of Science and Engineering; Tokyo Denki University; Hatoyama, Hiki-gun Saitama 350-0394 Japan
| | - Mari Okada
- Division of Science, School of Science and Engineering; Tokyo Denki University; Hatoyama, Hiki-gun Saitama 350-0394 Japan
| | - Masafumi Sugeno
- Division of Science, School of Science and Engineering; Tokyo Denki University; Hatoyama, Hiki-gun Saitama 350-0394 Japan
| | - Takayuki Norioka
- Division of Science, School of Science and Engineering; Tokyo Denki University; Hatoyama, Hiki-gun Saitama 350-0394 Japan
| |
Collapse
|
8
|
Kazemi SH, Shanehsaz M, Ghaemmaghami M. Non-Faradaic electrochemical impedance spectroscopy as a reliable and facile method: Determination of the potassium ion concentration using a guanine rich aptasensor. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 52:151-4. [PMID: 25953552 DOI: 10.1016/j.msec.2015.03.058] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2014] [Revised: 03/19/2015] [Accepted: 03/24/2015] [Indexed: 10/23/2022]
Abstract
In this article we report the application of non-Faradaic mode of electrochemical impedance spectroscopy (EIS) for determination of potassium ion (K(+)) concentration using a guanine rich K(+)-selective aptasensor (K(+)-aptasensor). This is a simple, electroactive probe free, sensitive and reproducible method allowing determination of K(+) ion concentration without any disturbance from electroactive probes used in similar works based on the Faradaic EIS method. Herein, a wide linear range of K(+) ion concentrations (1 μM-0.1mM) with a 200 nM limit of detection was achieved which is better than most of the previously reported Faradaic biosensing methods. The proposed method maintains valuable applications when it is used for K(+) determination in the presence of potentially important interferences in biological media. Thus, application of the non-Faradaic EIS method for sensing the concentration of K(+) ion with the presented K(+)-aptasensor can find an important role in clinical assay.
Collapse
Affiliation(s)
- Sayed Habib Kazemi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731, Iran.
| | - Maryam Shanehsaz
- Analytical Chemistry Research group, Research Institute of Petroleum Industry (RIPI), Tehran, Iran
| | - Mostafa Ghaemmaghami
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan 45137-66731, Iran
| |
Collapse
|
9
|
Baptista FR, Belhout SA, Giordani S, Quinn SJ. Recent developments in carbon nanomaterial sensors. Chem Soc Rev 2015; 44:4433-53. [DOI: 10.1039/c4cs00379a] [Citation(s) in RCA: 366] [Impact Index Per Article: 36.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The structural diversity of carbon nanomaterials provides an array of unique electronic, magnetic and optical properties, which when combined with their robust chemistry and ease of manipulation, makes them attractive candidates for sensor applications. In this review recent developments in the use of carbon nanoparticles and nanostructures as sensors and biosensors are explored.
Collapse
Affiliation(s)
| | - S. A. Belhout
- School of Chemistry
- University College Dublin
- Dublin 4
- Ireland
| | - S. Giordani
- Istituto Italiano di Tecnologia (IIT)
- Nano Carbon Materials
- Nanophysics Department
- 16163 Genova
- Italy
| | - S. J. Quinn
- School of Chemistry
- University College Dublin
- Dublin 4
- Ireland
| |
Collapse
|
10
|
Zhen SJ, Yu Y, Li CM, Huang CZ. Graphene oxide amplified fluorescence anisotropy for label-free detection of potassium ion. Analyst 2015; 140:353-7. [DOI: 10.1039/c4an01433b] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A label-free fluorescence anisotropy method for the sensitive detection of potassium ion, by using graphene oxide as enhancer, was established.
Collapse
Affiliation(s)
- Shu Jun Zhen
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- P.R. China
| | - Yan Yu
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Pharmaceutical Sciences
- Southwest University
- P.R. China
| | - Chun Mei Li
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Pharmaceutical Sciences
- Southwest University
- P.R. China
| | - Cheng Zhi Huang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- P.R. China
| |
Collapse
|