1
|
Alshubramy MA, Alamry KA, Alorfi HS, Ismail SH, Rezki N, Aouad MR, Al-Sodies S, Hussein MA. Room temperature sensing of CO 2 using C3-symmetry pyridinium-based porous ionic polymers with triazine or benzene cores. RSC Adv 2025; 15:3317-3330. [PMID: 39902105 PMCID: PMC11788645 DOI: 10.1039/d4ra07062c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2024] [Accepted: 01/16/2025] [Indexed: 02/05/2025] Open
Abstract
A new class of ionic polymers tethering triazine (benzene) core hybrids with three dipyridinium as cationic counterparts combined with bromide and/or chloride anions PPyBz-OBr and PPyTri-OCl were successfully prepared via the alkylation of 4,4'-dipyridyl derivatives 4,4'-bp-O with 1,3,5-tris(bromomethyl)benzene BB and/or cyanuric chloride CC. The precursor, 4,4'-bp-O,was synthesized through the condensation of 4-pyridine carboxaldehyde and 4,4'-oxydianiline. The resulting ionic polymers, PPyBz-OBr and PPyTri-OCl, underwent metathetical anion exchange, forming new ionic polymers bearing LiTFSI and KPF6 as anions. Characterization of the synthesized hybrid molecules was performed through FTIR, 1H NMR, and 13C NMR analyses. PXRD and SEM showed semi-crystalline structures and a homogenous distribution of micro-/or nanoparticles. TGA and DTA displayed high thermal stability of the synthesized polymer. The sensing activity of the modified ionic polymers was examined using a quartz crystal nanobalance (QCN) for CO2 detection. The resulting sensor demonstrated the ability to provide precise, selective, and reproducible CO2 measurements.
Collapse
Affiliation(s)
- Maha A Alshubramy
- Chemistry Department, Faculty of Science, King Abdulaziz University Jeddah 21589 Saudi Arabia
| | - Khalid A Alamry
- Chemistry Department, Faculty of Science, King Abdulaziz University Jeddah 21589 Saudi Arabia
| | - Hajar S Alorfi
- Chemistry Department, Faculty of Science, King Abdulaziz University Jeddah 21589 Saudi Arabia
| | - Sameh H Ismail
- Egypt Nanotechnology Center, Cairo University El-Sheikh Zayed, 6th October Giza Egypt
| | - Nadjet Rezki
- Department of Chemistry, Taibah University 30002 Al-Madina Al-Mounawara Saudi Arabia
| | - Mohamed Reda Aouad
- Department of Chemistry, Taibah University 30002 Al-Madina Al-Mounawara Saudi Arabia
| | - Salsabeel Al-Sodies
- Chemistry Department, Faculty of Science, King Abdulaziz University Jeddah 21589 Saudi Arabia
- Department of Chemistry, Taibah University 30002 Al-Madina Al-Mounawara Saudi Arabia
| | - Mahmoud A Hussein
- Chemistry Department, Faculty of Science, King Abdulaziz University Jeddah 21589 Saudi Arabia
- Chemistry Department, Faculty of Science, Assiut University Assiut 71516 Egypt
| |
Collapse
|
2
|
Song Y, Zhou Y, Zhang K, Fan Z, Zhang F, Wei M. Microfluidic programmable strategies for channels and flow. LAB ON A CHIP 2024; 24:4483-4513. [PMID: 39120605 DOI: 10.1039/d4lc00423j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/10/2024]
Abstract
This review summarizes programmable microfluidics, an advanced method for precise fluid control in microfluidic technology through microchannel design or liquid properties, referring to microvalves, micropumps, digital microfluidics, multiplexers, micromixers, slip-, and block-based configurations. Different microvalve types, including electrokinetic, hydraulic/pneumatic, pinch, phase-change and check valves, cater to diverse experimental needs. Programmable micropumps, such as passive and active micropumps, play a crucial role in achieving precise fluid control and automation. Due to their small size and high integration, microvalves and micropumps are widely used in medical devices and biological analysis. In addition, this review provides an in-depth exploration of the applications of digital microfluidics, multiplexed microfluidics, and mixer-based microfluidics in the manipulation of liquid movement, mixing, and splitting. These methodologies leverage the physical properties of liquids, such as capillary forces and dielectric forces, to achieve precise control over fluid dynamics. SlipChip technology, which branches into rotational SlipChip and translational SlipChip, controls fluid through sliding motion of the microchannel. On the other hand, innovative designs in microfluidic systems pursue better modularity, reconfigurability and ease of assembly. Different assembly strategies, from one-dimensional assembly blocks and two-dimensional Lego®-style blocks to three-dimensional reconfigurable modules, aim to enhance flexibility and accessibility. These technologies enhance user-friendliness and accessibility by offering integrated control systems, making them potentially usable outside of specialized technical labs. Microfluidic programmable strategies for channels and flow hold promising applications in biomedical research, chemical analysis and drug screening, providing theoretical and practical guidance for broader utilization in scientific research and practical applications.
Collapse
Affiliation(s)
- Yongxian Song
- School of Electronic Engineering, Nanjing Xiaozhuang University, Nanjing, Jiangsu 211171, China.
| | - Yijiang Zhou
- School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China.
| | - Kai Zhang
- School of Automation, Huaiyin Institute of Technology, Huaian, 223003, China.
| | - Zhaoxuan Fan
- Research Institute of Chemical Defence, Beijing 102205, China.
| | - Fei Zhang
- School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China.
| | - Mingji Wei
- School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China.
| |
Collapse
|
3
|
Yeganegi A, Yazdani K, Tasnim N, Fardindoost S, Hoorfar M. Microfluidic integrated gas sensors for smart analyte detection: a comprehensive review. Front Chem 2023; 11:1267187. [PMID: 37767341 PMCID: PMC10520252 DOI: 10.3389/fchem.2023.1267187] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 08/28/2023] [Indexed: 09/29/2023] Open
Abstract
The utilization of gas sensors has the potential to enhance worker safety, mitigate environmental issues, and enable early diagnosis of chronic diseases. However, traditional sensors designed for such applications are often bulky, expensive, difficult to operate, and require large sample volumes. By employing microfluidic technology to miniaturize gas sensors, we can address these challenges and usher in a new era of gas sensors suitable for point-of-care and point-of-use applications. In this review paper, we systematically categorize microfluidic gas sensors according to their applications in safety, biomedical, and environmental contexts. Furthermore, we delve into the integration of various types of gas sensors, such as optical, chemical, and physical sensors, within microfluidic platforms, highlighting the resultant enhancements in performance within these domains.
Collapse
Affiliation(s)
| | | | | | | | - Mina Hoorfar
- School of Engineering and Computer Science, University of Victoria, Victoria, BC, Canada
| |
Collapse
|
4
|
Mao J, Liu L, Atwa Y, Hou J, Wu Z, Shakeel H. Colorimetric Signal Readout for the Detection of Volatile Organic Compounds Using a Printable Glass-Based Dielectric Barrier Discharge-Type Helium Plasma Detector. ACS MEASUREMENT SCIENCE AU 2023; 3:287-300. [PMID: 37600462 PMCID: PMC10436375 DOI: 10.1021/acsmeasuresciau.3c00012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/18/2023] [Accepted: 05/18/2023] [Indexed: 08/22/2023]
Abstract
In this paper, we report on a printable glass-based manufacturing method and a new proof-of-concept colorimetric signal readout scheme for a dielectric barrier discharge (DBD)-type helium plasma photoionization detector. The sensor consists of a millimeter-sized glass chamber manufactured using a printable glass suspension. Plasma inside the chip is generated using a custom-built power supply (900 V and 83.6 kHz), and the detector uses ∼5 W of power. Our new detection scheme is based on detecting the change in the color of plasma after the introduction of target gases. The change in color is first captured by a smartphone camera as a video output. The recorded video is then processed and converted to an image light intensity vs retention time plot (gas chromatogram) using three standard color space models (red, green, blue (RGB), hue, saturation, lightness (HSL), and hue, saturation, value (HSV)) with RGB performing the best among the three models. We successfully detected three different categories of volatile organic compounds using our new detection scheme and a 30-m-long gas chromatography column: (1) straight-chain alkanes (n-pentane, n-hexane, n-heptane, n-octane, and n-nonane), (2) aromatics (benzene, toluene, and ethylbenzene), and (3) polar compounds (acetone, ethanol, and dichloromethane). The best limit of detection of 10 ng was achieved for benzene at room temperature. Additionally, the device showed excellent performance for different types of sample mixtures consisting of three and five compounds. Our new detector readout method combined with our ability to print complex glass structures provides a new research avenue to analyze complex gas mixtures and their components.
Collapse
Affiliation(s)
- Jingqin Mao
- School
of Electronics, Electrical Engineering and Computer Science, Queen’s University Belfast, Belfast BT7 1NN, U.K.
| | - Longze Liu
- School
of Electronics, Electrical Engineering and Computer Science, Queen’s University Belfast, Belfast BT7 1NN, U.K.
| | - Yahya Atwa
- School
of Electronics, Electrical Engineering and Computer Science, Queen’s University Belfast, Belfast BT7 1NN, U.K.
| | - Junming Hou
- State
Key Laboratory of Millimeter Waves, School of Information Science
and Engineering, Southeast University, Nanjing 210096, China
| | - Zhenxun Wu
- Queen’s
Management School, Queen’s University
Belfast, Belfast BT7 1NN, U.K.
| | - Hamza Shakeel
- School
of Electronics, Electrical Engineering and Computer Science, Queen’s University Belfast, Belfast BT7 1NN, U.K.
| |
Collapse
|
5
|
Li X, Wang F, Xia C, The HL, Bomer JG, Wang Y. Laser Controlled Manipulation of Microbubbles on a Surface with Silica-Coated Gold Nanoparticle Array. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023:e2302939. [PMID: 37496086 DOI: 10.1002/smll.202302939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 07/13/2023] [Indexed: 07/28/2023]
Abstract
Microbubble generation and manipulation play critical roles in diverse applications such as microfluidic mixing, pumping, and microrobot propulsion. However, existing methods are typically limited to lateral movements on customized substrates or rely on specific liquids with particular properties or designed concentration gradients, thereby hindering their practical applications. To address this challenge, this paper presents a method that enables robust vertical manipulation of microbubbles. By focusing a resonant laser on hydrophilic silica-coated gold nanoparticle arrays immersed in water, plasmonic microbubbles are generated and detach from the substrates immediately upon cessation of laser irradiation. Using simple laser pulse control, it can achieve an adjustable size and frequency of bubble bouncing, which is governed by the movement of the three-phase contact line during surface wetting. Furthermore, it demonstrates that rising bubbles can be pulled back by laser irradiation induced thermal Marangoni flow, which is verified by particle image velocimetry measurements and numerical simulations. This study provides novel insights into flexible bubble manipulation and integration in microfluidics, with significant implications for various applications including mixing, drug delivery, and the development of soft actuators.
Collapse
Affiliation(s)
- Xiaolai Li
- Robotics Institute, School of Mechanical Engineering and Automation, Beihang University, Beijing, 100191, P. R. China
| | - Fulong Wang
- Robotics Institute, School of Mechanical Engineering and Automation, Beihang University, Beijing, 100191, P. R. China
| | - Chenliang Xia
- Robotics Institute, School of Mechanical Engineering and Automation, Beihang University, Beijing, 100191, P. R. China
| | - Hai Le The
- BIOS Lab-on-a-chip, University of Twente, Enschede, P.O. Box 217, 7500AE, The Netherlands
- Physics of Fluids, Max Planck Center Twente for Complex Fluid Dynamics and J.M. Burgers Centre for Fluid Mechanics, University of Twente, Enschede, P.O. Box 217, 7500AE, The Netherlands
| | - Johan G Bomer
- BIOS Lab-on-a-chip, University of Twente, Enschede, P.O. Box 217, 7500AE, The Netherlands
| | - Yuliang Wang
- Robotics Institute, School of Mechanical Engineering and Automation, Beihang University, Beijing, 100191, P. R. China
- Ningbo Institute of Technology, Beihang University, Ningbo, 315832, P. R. China
| |
Collapse
|
6
|
Crucello J, de Oliveira AM, Sampaio NMFM, Hantao LW. Miniaturized systems for gas chromatography: Developments in sample preparation and instrumentation. J Chromatogr A 2022; 1685:463603. [DOI: 10.1016/j.chroma.2022.463603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/07/2022] [Accepted: 10/23/2022] [Indexed: 11/07/2022]
|
7
|
Kaaliveetil S, Yang J, Alssaidy S, Li Z, Cheng YH, Menon NH, Chande C, Basuray S. Microfluidic Gas Sensors: Detection Principle and Applications. MICROMACHINES 2022; 13:1716. [PMID: 36296069 PMCID: PMC9607434 DOI: 10.3390/mi13101716] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/08/2022] [Accepted: 10/09/2022] [Indexed: 06/16/2023]
Abstract
With the rapid growth of emerging point-of-use (POU)/point-of-care (POC) detection technologies, miniaturized sensors for the real-time detection of gases and airborne pathogens have become essential to fight pollution, emerging contaminants, and pandemics. However, the low-cost development of miniaturized gas sensors without compromising selectivity, sensitivity, and response time remains challenging. Microfluidics is a promising technology that has been exploited for decades to overcome such limitations, making it an excellent candidate for POU/POC. However, microfluidic-based gas sensors remain a nascent field. In this review, the evolution of microfluidic gas sensors from basic electronic techniques to more advanced optical techniques such as surface-enhanced Raman spectroscopy to detect analytes is documented in detail. This paper focuses on the various detection methodologies used in microfluidic-based devices for detecting gases and airborne pathogens. Non-continuous microfluidic devices such as bubble/droplet-based microfluidics technology that have been employed to detect gases and airborne pathogens are also discussed. The selectivity, sensitivity, advantages/disadvantages vis-a-vis response time, and fabrication costs for all the microfluidic sensors are tabulated. The microfluidic sensors are grouped based on the target moiety, such as air pollutants such as carbon monoxide and nitrogen oxides, and airborne pathogens such as E. coli and SARS-CoV-2. The possible application scenarios for the various microfluidic devices are critically examined.
Collapse
Affiliation(s)
- Sreerag Kaaliveetil
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Juliana Yang
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Saud Alssaidy
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Zhenglong Li
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Yu-Hsuan Cheng
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Niranjan Haridas Menon
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Charmi Chande
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| | - Sagnik Basuray
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ 07102, USA
| |
Collapse
|
8
|
Shahrbabaki Z, Oveissi F, Farajikhah S, Ghasemian MB, Jansen-van Vuuren RD, Jessop PG, Yun J, Dehghani F, Naficy S. Electrical Response of Poly( N-[3-(dimethylamino)Propyl] Methacrylamide) to CO 2 at a Long Exposure Period. ACS OMEGA 2022; 7:22232-22243. [PMID: 35811921 PMCID: PMC9260916 DOI: 10.1021/acsomega.2c00914] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 06/08/2022] [Indexed: 05/20/2023]
Abstract
Amine-functionalized polymers (AFPs) are able to react with carbon dioxide (CO2) and are therefore useful in CO2 capture and sensing. To develop AFP-based CO2 sensors, it is critical to examine their electrical responses to CO2 over long periods of time, so that the device can be used consistently for measuring CO2 concentration. To this end, we synthesized poly(N-[3-(dimethylamino)propyl] methacrylamide) (pDMAPMAm) by free radical polymerization and tested its ability to behave as a CO2-responsive polymer in a transducer. The electrical response of this polymer to CO2 upon long exposure times was measured in both the aqueous and solid phases. Direct current resistance measurement tests on pDMAPMAm films printed along with the silver electrodes in the presence of CO2 at various concentrations reveal a two-region electrical response. Upon continuous exposure to different CO2 flow rates (at a constant pressure of 0.2 MPa), the resistance first decreased over time, reaching a minimum, followed by a gradual increase with further exposure to CO2. A similar trend is observed when CO2 is introduced to an aqueous solution of pDMAPMAm. The in situ monitoring of pH suggests that the change in resistance of pDMAPMAm can be attributed to the protonation of tertiary amine groups in the presence of CO2. This two-region response of pDMAPMAm is based on a proton-hopping mechanism and a change in the number of free amines when pDMAPMAm is exposed to various levels of CO2.
Collapse
Affiliation(s)
- Zahra Shahrbabaki
- School
of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Farshad Oveissi
- School
of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Syamak Farajikhah
- School
of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW 2006, Australia
- The
University of Sydney, Sydney Nano Institute, NSW 2006, Australia
| | - Mohammad B. Ghasemian
- School
of Chemical Engineering, University of New
South Wales (UNSW), Sydney, NSW 2052, Australia
| | - Ross D. Jansen-van Vuuren
- Faculty
of Chemistry and Chemical Technology, University
of Ljubljana, Večna
Pot 113, 1000 Ljubljana, Slovenia
| | - Philip G. Jessop
- Department
of Chemistry, Queen’s University, Kingston, Ontario K7L 3N6, Canada
| | - Jimmy Yun
- School
of Chemical Engineering, University of New
South Wales (UNSW), Sydney, NSW 2052, Australia
- Qingdao
International Academician Park Research Institute, Qingdao, Shandong 266104, PR China
| | - Fariba Dehghani
- School
of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW 2006, Australia
- The
University of Sydney, Sydney Nano Institute, NSW 2006, Australia
| | - Sina Naficy
- School
of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
9
|
An S, Ranaweera R, Luo L. Harnessing bubble behaviors for developing new analytical strategies. Analyst 2021; 145:7782-7795. [PMID: 33107897 DOI: 10.1039/d0an01497d] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Gas bubbles are easily accessible and offer many unique characteristic properties of a gas/liquid two-phase system for developing new analytical methods. In this minireview, we discuss the newly developed analytical strategies that harness the behaviors of bubbles. Recent advancements include the utilization of the gas/liquid interfacial activity of bubbles for detection and preconcentration of surface-active compounds; the employment of the gas phase properties of bubbles for acoustic imaging and detection, microfluidic analysis, electrochemical sensing, and emission spectroscopy; and the application of the mass transport behaviors at the gas/liquid interface in gas sensing, biosensing, and nanofluidics. These studies have demonstrated the versatility of gas bubbles as a platform for developing new analytical strategies.
Collapse
Affiliation(s)
- Shizhong An
- School of Materials Science and Engineering, Henan University of Science and Technology, Luoyang 471023, China
| | | | | |
Collapse
|
10
|
Ma P, Wang S, Guan R, Hu L, Wang X, Ge A, Zhu J, Du W, Liu BF. An integrated microfluidic device for studying controllable gas embolism induced cellular responses. Talanta 2019; 208:120484. [PMID: 31816727 DOI: 10.1016/j.talanta.2019.120484] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 10/15/2019] [Accepted: 10/18/2019] [Indexed: 01/05/2023]
Abstract
Gas embolism is the abnormal emergence of bubble in the vascular system, which can induce local ischemic symptoms. For studying the mechanism underlying gas embolism and revealing local ischemic diseases information, novel technique for analyzing cells response to bubble contact with high controllability is highly desired. In this paper, we present an integrated microfluidic device for the precise generation and control of microbubble based on the gas permeability of polydimethysiloxane (PDMS) to study the effect of bubble's mechanical contact on cells. Cell viability analysis demonstrated that short-term (<15 min) bubble contact was generally non-lethal to cultured endothelial cells. The significant increase in intracellular calcium of the microbubble-contacted cells and cell-to-cell propagation of calcium signal in the adjacent cells were observed during the process of bubble expansion. In addition, the analysis of intercellular calcium signal in the cells treated with suramin and octanol revealed that cell-released small nucleotides and gap junction played an important role in regulating the propagation of calcium wave triggered by bubble contact. Thus, our microfluidic method provides an effective platform for studying the effect of gas embolism on cultured adherent cells and can be further needed for anti-embolism drugs test.
Collapse
Affiliation(s)
- Peng Ma
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Shanshan Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China; BGI Education Center, University of Chinese Academy of Sciences, Shenzhen 518083, China
| | - Ruixue Guan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Liang Hu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China; School of Ophthalmology & Optometry, School of Biomedical Engineering, Wenzhou Medical University, Wenzhou, Zhejiang, 325035, China
| | - Xixian Wang
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China; Single Cell Center, CAS Key Laboratory of Biofuels and Shandong Key Laboratory of Energy Genetics, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101, China
| | - Anle Ge
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China; Single Cell Center, CAS Key Laboratory of Biofuels and Shandong Key Laboratory of Energy Genetics, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101, China
| | - Jinchi Zhu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wei Du
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
11
|
Pereiro I, Fomitcheva Khartchenko A, Petrini L, Kaigala GV. Nip the bubble in the bud: a guide to avoid gas nucleation in microfluidics. LAB ON A CHIP 2019; 19:2296-2314. [PMID: 31168556 DOI: 10.1039/c9lc00211a] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Gas bubbles are almost a routine occurrence encountered by researchers working in the field of microfluidics. The spontaneous and unexpected nature of gas bubbles represents a major challenge for experimentalists and a stumbling block for the translation of microfluidic concepts to commercial products. This is a startling example of successful scientific results in the field overshadowing the practical hurdles of day-to-day usage. We however believe such hurdles can be overcome with a sound understanding of the underlying conditions that lead to bubble formation. In this tutorial, we focus on the two main conditions that result in bubble nucleation: surface nuclei and gas supersaturation in liquids. Key theoretical concepts such as Henry's law, Laplace pressure, the role of surface properties, nanobubbles and surfactants are presented along with a view of practical implementations that serve as preventive and curative measures. These considerations include not only microfluidic chip design and bubble traps but also often-overlooked conditions that regulate bubble formation, such as gas saturation under pressure or temperature gradients. Scenarios involving electrolysis, laser and acoustic cavitation or T-junction/co-flow geometries are also explored to provide the reader with a broader understanding on the topic. Interestingly, despite their often-disruptive nature, gas bubbles have also been cleverly utilized for certain practical applications, which we briefly review. We hope this tutorial will provide a reference guide in helping to deal with a familiar foe, the "bubble".
Collapse
Affiliation(s)
- Iago Pereiro
- IBM Research - Zurich, Säumerstrasse 4, Rüschlikon, CH-8803, Switzerland.
| | | | | | | |
Collapse
|
12
|
Ha JH, Mazumdar H, Kim TH, Lee JM, Na JG, Chung BG. Algorithm Analysis of Gas Bubble Generation in a Microfluidic Device. BIOCHIP JOURNAL 2019. [DOI: 10.1007/s13206-018-3203-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
13
|
Seo S, Nguyen M, Mastiani M, Navarrete G, Kim M. Microbubbles Loaded with Nickel Nanoparticles: A Perspective for Carbon Sequestration. Anal Chem 2017; 89:10827-10833. [DOI: 10.1021/acs.analchem.7b02205] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Seokju Seo
- Department of Ocean and Mechanical
Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| | - Minh Nguyen
- Department of Ocean and Mechanical
Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| | - Mohammad Mastiani
- Department of Ocean and Mechanical
Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| | - Gabriel Navarrete
- Department of Ocean and Mechanical
Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| | - Myeongsub Kim
- Department of Ocean and Mechanical
Engineering, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| |
Collapse
|
14
|
Lee J, Zhou M, Zhu H, Nidetz R, Kurabayashi K, Fan X. Fully Automated Portable Comprehensive 2-Dimensional Gas Chromatography Device. Anal Chem 2016; 88:10266-10274. [PMID: 27709906 DOI: 10.1021/acs.analchem.6b03000] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
We developed a fully automated portable 2-dimensional (2-D) gas chromatography (GC x GC) device, which had a dimension of 60 cm × 50 cm × 10 cm and weight less than 5 kg. The device incorporated a micropreconcentrator/injector, commercial columns, micro-Deans switches, microthermal injectors, microphotoionization detectors, data acquisition cards, and power supplies, as well as computer control and user interface. It employed multiple channels (4 channels) in the second dimension (2D) to increase the 2D separation time (up to 32 s) and hence 2D peak capacity. In addition, a nondestructive flow-through vapor detector was installed at the end of the 1D column to monitor the eluent from 1D and assist in reconstructing 1D elution peaks. With the information obtained jointly from the 1D and 2D detectors, 1D elution peaks could be reconstructed with significantly improved 1D resolution. In this Article, we first discuss the details of the system operating principle and the algorithm to reconstruct 1D elution peaks, followed by the description and characterization of each component. Finally, 2-D separation of 50 analytes, including alkane (C6-C12), alkene, alcohol, aldehyde, ketone, cycloalkane, and aromatic hydrocarbon, in 14 min is demonstrated, showing the peak capacity of 430-530 and the peak capacity production of 40-80/min.
Collapse
Affiliation(s)
- Jiwon Lee
- Department of Biomedical Engineering, University of Michigan , 1101 Beal Avenue, Ann Arbor, Michigan 48109, United States.,Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Menglian Zhou
- Department of Biomedical Engineering, University of Michigan , 1101 Beal Avenue, Ann Arbor, Michigan 48109, United States.,Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Hongbo Zhu
- Department of Biomedical Engineering, University of Michigan , 1101 Beal Avenue, Ann Arbor, Michigan 48109, United States.,Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan , Ann Arbor, Michigan 48109, United States
| | - Robert Nidetz
- Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan , Ann Arbor, Michigan 48109, United States.,Department of Mechanical Engineering, University of Michigan , 2350 Hayward, Ann Arbor, Michigan 48109, United States
| | - Katsuo Kurabayashi
- Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan , Ann Arbor, Michigan 48109, United States.,Department of Mechanical Engineering, University of Michigan , 2350 Hayward, Ann Arbor, Michigan 48109, United States
| | - Xudong Fan
- Department of Biomedical Engineering, University of Michigan , 1101 Beal Avenue, Ann Arbor, Michigan 48109, United States.,Center for Wireless Integrated MicroSensing and Systems (WIMS2), University of Michigan , Ann Arbor, Michigan 48109, United States
| |
Collapse
|
15
|
Hsieh HC, Kim H. A miniature closed-loop gas chromatography system. LAB ON A CHIP 2016; 16:1002-1012. [PMID: 26911622 DOI: 10.1039/c5lc01553g] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper reports the characterization of a miniaturized circulatory column system that is capable of magnifying the effective column length by forming a circulatory loop with chip-scale columns, thus ultimately achieving high-efficiency target separation. The circulatory column system is composed of a tandem of 25 cm microcolumns and six valves for fluidic flow control in order to enable chromatographic separation in circulatory motions while requiring only 5.5 kPa of pressure, which current micropumps are currently capable of supplying. The developed column system (1) successfully demonstrated 16 times elongation of a virtual column length up to 800 cm by only utilizing two 25 cm microcolumns, which is the longest column length reported by any MEMS-scale functioning GC column, (2) achieved a high theoretical plate number of 68,696 with pentane circulating after 15.5 circulatory cycles, which corresponds to the plate number per length-pressure of 1611 plate m(-1) kPa(-1), the highest record reported yet, and (3) demonstrated successful separation of target molecules during circulation by utilizing a pentane/hexane mixture, resulting in magnification of the two corresponding peaks via circulation.
Collapse
Affiliation(s)
- Hao-Chieh Hsieh
- Department of Electrical & Computer Engineering, University of Utah, SMBB-3100, 36 South Wasatch Drive, Salt Lake City, UT 84112, USA.
| | | |
Collapse
|
16
|
Wang J, Guo J, Si P, Cai W, Wang Y, Wu G. Polydopamine-based synthesis of an In(OH)3–PDMS sponge for ammonia detection by switching surface wettability. RSC Adv 2016. [DOI: 10.1039/c5ra23484k] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
An In(OH)3–PDMS sponge has been synthesized by covalent modification of PDA.
Collapse
Affiliation(s)
- Jikui Wang
- Shanghai Key Laboratory of Advanced Polymeric Materials
- Key Laboratory for Ultrafine Materials of Ministry of Education
- School of Materials Science and Engineering
- East China University of Science and Technology
- Shanghai 200237
| | - Jiahong Guo
- Shanghai Key Laboratory of Advanced Polymeric Materials
- Key Laboratory for Ultrafine Materials of Ministry of Education
- School of Materials Science and Engineering
- East China University of Science and Technology
- Shanghai 200237
| | - Pengxiang Si
- Shanghai Key Laboratory of Advanced Polymeric Materials
- Key Laboratory for Ultrafine Materials of Ministry of Education
- School of Materials Science and Engineering
- East China University of Science and Technology
- Shanghai 200237
| | - Wanping Cai
- Shanghai Key Laboratory of Advanced Polymeric Materials
- Key Laboratory for Ultrafine Materials of Ministry of Education
- School of Materials Science and Engineering
- East China University of Science and Technology
- Shanghai 200237
| | - Yuming Wang
- Shanghai Key Laboratory of Advanced Polymeric Materials
- Key Laboratory for Ultrafine Materials of Ministry of Education
- School of Materials Science and Engineering
- East China University of Science and Technology
- Shanghai 200237
| | - Genhua Wu
- Shanghai Key Laboratory of Advanced Polymeric Materials
- Key Laboratory for Ultrafine Materials of Ministry of Education
- School of Materials Science and Engineering
- East China University of Science and Technology
- Shanghai 200237
| |
Collapse
|
17
|
Zhou M, Lee J, Zhu H, Nidetz R, Kurabayashi K, Fan X. A fully automated portable gas chromatography system for sensitive and rapid quantification of volatile organic compounds in water. RSC Adv 2016. [DOI: 10.1039/c6ra09131h] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
We present an automated portable GC system for the rapid and sensitive detection of VOCs in water.
Collapse
Affiliation(s)
- Menglian Zhou
- Department of Biomedical Engineering
- University of Michigan
- Ann Arbor
- USA
- Center for Wireless Integrated MicroSensing and Systems (WIMS2)
| | - Jiwon Lee
- Department of Biomedical Engineering
- University of Michigan
- Ann Arbor
- USA
- Center for Wireless Integrated MicroSensing and Systems (WIMS2)
| | - Hongbo Zhu
- Department of Biomedical Engineering
- University of Michigan
- Ann Arbor
- USA
- Center for Wireless Integrated MicroSensing and Systems (WIMS2)
| | - Robert Nidetz
- Center for Wireless Integrated MicroSensing and Systems (WIMS2)
- University of Michigan
- Ann Arbor
- USA
- Department of Mechanical Engineering
| | - Katsuo Kurabayashi
- Center for Wireless Integrated MicroSensing and Systems (WIMS2)
- University of Michigan
- Ann Arbor
- USA
- Department of Mechanical Engineering
| | - Xudong Fan
- Department of Biomedical Engineering
- University of Michigan
- Ann Arbor
- USA
- Center for Wireless Integrated MicroSensing and Systems (WIMS2)
| |
Collapse
|
18
|
Patabadige DEW, Jia S, Sibbitts J, Sadeghi J, Sellens K, Culbertson CT. Micro Total Analysis Systems: Fundamental Advances and Applications. Anal Chem 2015; 88:320-38. [DOI: 10.1021/acs.analchem.5b04310] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Damith E. W. Patabadige
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Shu Jia
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Jay Sibbitts
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Jalal Sadeghi
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
- Laser & Plasma Research Institute, Shahid Beheshti University, Evin, Tehran, 1983963113, Iran
| | - Kathleen Sellens
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| | - Christopher T. Culbertson
- Department
of Chemistry, Kansas State University, 213 CBC Building, Manhattan, Kansas 66506, United States
| |
Collapse
|