1
|
Xiao H, Wei S, Gu M, Chen Z, Cao L. A sandwich-type electrochemical immunosensor using rGO-TEPA-Thi-Au as sensitive platform and CMK-3@AuPtNPs as signal probe for AFP detection. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106641] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
2
|
A novel affinity peptide-antibody sandwich electrochemical biosensor for PSA based on the signal amplification of MnO 2-functionalized covalent organic framework. Talanta 2021; 233:122520. [PMID: 34215135 DOI: 10.1016/j.talanta.2021.122520] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 05/05/2021] [Accepted: 05/11/2021] [Indexed: 12/19/2022]
Abstract
This work describes a novel affinity peptide-antibody sandwich electrochemical strategy for the ultrasensitive detection of prostate-specific antigen (PSA). Herein, polydopamine-coated boron-doped carbon nitride (Au@PDA@BCN) was synthesized and used as a sensing platform to anchor gold nanoparticles and immobilize primary antibody. Meanwhile, AuPt metallic nanoparticle and manganese dioxide (MnO2)-functionalized covalent organic frameworks (AuPt@MnO2@COF) was facilely synthesized to serve as a nanocatalyst and ordered nanopore for the enrichment and amplification of signal molecules (methylene blue, MB). PSA affinity peptide was bound to AuPt@MnO2@COF to form Pep/MB/AuPt@MnO2@COF nanocomposites (probe). The peptide-PSA-antibody sandwich biosensor was constructed, and the redox signal of MB was measured with the existence of PSA. The fabricated sensor exhibited a linear response (0.00005-10 ng mL-1) with a low detection limit of 16.7 fg mL-1 under the optimum condition. Additionally, the sensor showed an excellent selectivity, ideal repeatability, and good stability for PSA detection in real samples. Furthermore, the porous structure of COF can enrich more MB molecules and increase the sensitivity of the biosensor. This study provides an efficient and ultrasensitive strategy for PSA detection and broadens the use of organic/inorganic porous nanocomposite in biosensing.
Collapse
|
3
|
Rong S, Zou L, Li Y, Guan Y, Guan H, Zhang Z, Zhang Y, Gao H, Yu H, Zhao F, Pan H, Chang D. An ultrasensitive disposable sandwich-configuration electrochemical immunosensor based on OMC@AuNPs composites and AuPt-MB for alpha-fetoprotein detection. Bioelectrochemistry 2021; 141:107846. [PMID: 34087545 DOI: 10.1016/j.bioelechem.2021.107846] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 05/13/2021] [Accepted: 05/17/2021] [Indexed: 01/20/2023]
Abstract
Early finding and diagnosis are critical for prevention and treatment of hepatocellular carcinoma (HCC). Alpha-fetoprotein (AFP) is a typical biomarker of HCC. Since AFP level can reflect the severity of HCC, it is essential to ensure the accurate detection of AFP. In this study, through a combination of the advantages exhibited by ordered mesoporous carbon (OMC)@gold nanoparticles (AuNPs) composites and AuPt-methylene blue (AuPt-MB), a disposable ultrasensitive sandwich-configuration electrochemical immunosensor for determination of AFP was designed. Characterized by excellent conductivity, highly ordered pore distribution and great surface area, OMC can be effective in promoting electron transfer and loading a large number of AuNPs. In the meantime, AuNPs can also immobilize AFP-Ab1 through Au-N bonds. As a new redox-active species, rod-like AuPt-MB demonstrates high conductivity, uniform morphology and excellent biocompatibility, which makes it capable not only to fix AFP-Ab2, but also to release electrochemical signals. A wide linearity of 10 fg mL-1-100 ng mL-1 and a low detection limit of 3.33 fg mL-1 (S/N = 3) were obtained. Moreover, the proposed immunosensor exhibited acceptable selectivity, high stability and reproducibility. The excellent performance in detecting serum samples endows the proposed immunosensor with broad prospects of extensive application in the detection of disease biomarkers.
Collapse
Affiliation(s)
- Shengzhong Rong
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai, China; Public Health School, Mudanjiang Medical University, Mudanjiang, China
| | - Lina Zou
- The Affiliated Hongqi Hospital, Mudanjiang Medical University, Mudanjiang, China
| | - Yang Li
- Department of Orthopedic Surgery, the First Affiliated Hospital of Harbin Medical University, Harbin, China
| | - Yue Guan
- Heilongjiang Nursing College, Harbin, China
| | - Huilin Guan
- Public Health School, Mudanjiang Medical University, Mudanjiang, China
| | - Ze Zhang
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai, China
| | - Yingcong Zhang
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai, China
| | - Hongmin Gao
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai, China
| | - Hongwei Yu
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai, China
| | - Fuyang Zhao
- Public Health School, Mudanjiang Medical University, Mudanjiang, China
| | - Hongzhi Pan
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai, China.
| | - Dong Chang
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai, China.
| |
Collapse
|
4
|
Status Update on Bioelectrochemical Systems: Prospects for Carbon Electrode Design and Scale-Up. Catalysts 2021. [DOI: 10.3390/catal11020278] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Bioelectrochemical systems (BES) employ enzymes, subcellular structures or whole electroactive microorganisms as biocatalysts for energy conversion purposes, such as the electrosynthesis of value-added chemicals and power generation in biofuel cells. From a bioelectrode engineering viewpoint, customizable nanostructured carbonaceous matrices have recently received considerable scientific attention as promising electrode supports due to their unique properties attractive to bioelectronics devices. This review demonstrates the latest advances in the application of nano- and micro-structured carbon electrode assemblies in BES. Specifically, in view of the gradual increase in the commercial applicability of these systems, we aim to address the stability and scalability of different BES designs and to highlight their potential roles in a circular bioeconomy.
Collapse
|
5
|
Dowlatshahi S, Abdekhodaie MJ. Electrochemical prostate-specific antigen biosensors based on electroconductive nanomaterials and polymers. Clin Chim Acta 2021; 516:111-135. [PMID: 33545110 DOI: 10.1016/j.cca.2021.01.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 01/23/2021] [Accepted: 01/26/2021] [Indexed: 01/11/2023]
Abstract
Prostate cancer (PCa), the second most malignant neoplasm in men, is also the fifth leading cause of cancer-related deaths in men globally. Unfortunately, this malignancy remains largely asymptomatic until late-stage emergence when treatment is limited due to the lack of effective metastatic PCa therapeutics. Due to these limitations, early PCa detection through prostate-specific antigen (PSA) screening has become increasingly important, resulting in a more than 50% decrease in mortality. Conventional assays for PSA detection, such as enzyme-linked immunosorbent assay (ELISA), are labor intensive, relatively expensive, operator-dependent and do not provide adequate sensitivity. Electrochemical biosensors overcome these limitations because they are rapid, cost-effective, simple to use and ultrasensitive. This article reviews electrochemical PSA biosensors using electroconductive nanomaterials such as carbon-, metal-, metal oxide- and peptide-based nanostructures, as well as polymers to significantly improve conductivity and enhance sensitivity. Challenges associated with the development of these devices are discussed thus providing additional insight into their analytic strength as well as their potential use in early PCa detection.
Collapse
Affiliation(s)
- Sayeh Dowlatshahi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Mohammad J Abdekhodaie
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran; Yeates School of Graduate Studies, Ryerson University, Toronto, Ontario, Canada.
| |
Collapse
|
6
|
Electrochemical immunoassay for the carcinoembryonic antigen based on Au NPs modified zeolitic imidazolate framework and ordered mesoporous carbon. Mikrochim Acta 2020; 187:264. [DOI: 10.1007/s00604-020-04235-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2019] [Accepted: 03/24/2020] [Indexed: 01/09/2023]
|
7
|
Negahdary M, Sattarahmady N, Heli H. Advances in prostate specific antigen biosensors-impact of nanotechnology. Clin Chim Acta 2020; 504:43-55. [PMID: 32004532 DOI: 10.1016/j.cca.2020.01.028] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/25/2020] [Accepted: 01/27/2020] [Indexed: 01/01/2023]
Abstract
Prostate cancer is one of the most dangerous and deadly cancers in elderly men. Early diagnosis using prostate-specific antigen (PSA) facilitates disease detection, management and treatment. Biosensors have recently been used as sensitive, selective, inexpensive and rapid diagnostic tools for PSA detection. In this review, a variety of PSA biosensors such as aptasensors, peptisensors and immunesensors are highlighted. These use aptamers, peptides and antibodies in the biorecognition element, respectively, and can detect PSA with very high sensitivity via electrochemical, electrochemiluminescence, fluorescence and surface-enhanced Raman spectroscopy. To improve the sensitivity of most of these PSA biosensors, different nanostructured materials have played a critical role.
Collapse
Affiliation(s)
- M Negahdary
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| | - N Sattarahmady
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran; Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - H Heli
- Nanomedicine and Nanobiology Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
| |
Collapse
|
8
|
Ultrasensitive electrochemical sensor for prostate specific antigen detection with a phosphorene platform and magnetic covalent organic framework signal amplifier. Biosens Bioelectron 2019; 144:111691. [DOI: 10.1016/j.bios.2019.111691] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 09/05/2019] [Accepted: 09/06/2019] [Indexed: 01/06/2023]
|
9
|
Zhou X, Qian X, Tan X, Ran X, Li Z, Huang Z, Yang L, Xie X. Water-soluble pillar[6]arene functionalized PdPt porous core-shell octahedral nanodendrites to construct highly sensitive and robust neuron-specific enolase immunosensor by host-guest chemistry assisted catalytic amplification. Anal Chim Acta 2019; 1068:18-27. [DOI: 10.1016/j.aca.2019.04.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 04/02/2019] [Accepted: 04/09/2019] [Indexed: 12/18/2022]
|
10
|
Zhou X, Yang L, Tan X, Zhao G, Xie X, Du G. A robust electrochemical immunosensor based on hydroxyl pillar[5]arene@AuNPs@g-C3N4 hybrid nanomaterial for ultrasensitive detection of prostate specific antigen. Biosens Bioelectron 2018; 112:31-39. [DOI: 10.1016/j.bios.2018.04.036] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 04/14/2018] [Accepted: 04/16/2018] [Indexed: 12/14/2022]
|
11
|
Freitas M, Nouws HPA, Delerue-Matos C. Electrochemical Biosensing in Cancer Diagnostics and Follow-up. ELECTROANAL 2018. [DOI: 10.1002/elan.201800193] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Maria Freitas
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto; Politécnico do Porto, Rua Dr. António Bernardino de Almeida; 4200-072 Porto Portugal
| | - Henri P. A. Nouws
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto; Politécnico do Porto, Rua Dr. António Bernardino de Almeida; 4200-072 Porto Portugal
| | - Cristina Delerue-Matos
- REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto; Politécnico do Porto, Rua Dr. António Bernardino de Almeida; 4200-072 Porto Portugal
| |
Collapse
|
12
|
Walcarius A. Recent Trends on Electrochemical Sensors Based on Ordered Mesoporous Carbon. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1863. [PMID: 28800106 PMCID: PMC5579580 DOI: 10.3390/s17081863] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2017] [Revised: 08/09/2017] [Accepted: 08/10/2017] [Indexed: 01/27/2023]
Abstract
The past decade has seen an increasing number of extensive studies devoted to the exploitation of ordered mesoporous carbon (OMC) materials in electrochemistry, notably in the fields of energy and sensing. The present review summarizes the recent achievements made in field of electroanalysis using electrodes modified with such nanomaterials. On the basis of comprehensive tables, the interest in OMC for designing electrochemical sensors is illustrated through the various applications developed to date. They include voltammetric detection after preconcentration, electrocatalysis (intrinsically due to OMC or based on suitable catalysts deposited onto OMC), electrochemical biosensors, as well as electrochemiluminescence and potentiometric sensors.
Collapse
Affiliation(s)
- Alain Walcarius
- Laboratoire de Chimie Physique et Microbiologie Pour l'Environnement (LCPME), UMR 7564, CNRS-Université de Lorraine, 405 rue de Vandoeuvre, 54600 Villers-les-Nancy, France.
| |
Collapse
|
13
|
An integrated lab-on-a-chip-based electrochemical biosensor for rapid and sensitive detection of cancer biomarkers. Anal Bioanal Chem 2016; 408:7775-7783. [PMID: 27562751 DOI: 10.1007/s00216-016-9879-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2016] [Revised: 08/08/2016] [Accepted: 08/12/2016] [Indexed: 01/10/2023]
Abstract
Recent advances in the area of biosensor technology and microfluidic applications have enabled the miniaturisation of the sensing platforms. Here we describe a new integrated and fully automated lab-on-a-chip-based biosensor device prototype (MiSens) that has potential to be used for point-of-care cancer biomarker testing. The key features of the device include a new biochip, a device integrated microfluidic system and real-time amperometric measurements during the flow of enzyme substrate. For ease of use, a new plug and play type sensor chip docking station has been designed. This system allows the formation of an ∼7 μL capacity flow cell on the electrode array with the necessary microfluidic and electronic connections with one move of a handle. As a case study, the developed prototype has been utilised for the detection of prostate-specific antigen (PSA) level in serum that is routinely used as a biomarker for the diagnosis of prostate cancer. The patient samples from a nearby hospital have been collected and tested using the MiSens device, and the results have been compared to the hospital results. The obtained results indicate the potential of the MiSens device as a useful tool for point-of-care testing. Graphical abstract Microfluidics integrated and automated electrochemical biosensor device "MiSens" has been designed and fabricated by a multidisciplinary team and utilised to detect PSA from clinical samples.
Collapse
|