1
|
Behera K, Mutharani B, Chang YH, Kumari M, Chiu FC. Protein-Aided Synthesis of Copper-Integrated Polyaniline Nanocomposite Encapsulated with Reduced Graphene Oxide for Highly Sensitive Electrochemical Detection of Dimetridazole in Real Samples. Polymers (Basel) 2024; 16:162. [PMID: 38201827 PMCID: PMC10781186 DOI: 10.3390/polym16010162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 12/28/2023] [Accepted: 12/28/2023] [Indexed: 01/12/2024] Open
Abstract
Dimetridazole (DMZ) is a derivative of nitroimidazole and is a veterinary drug used as an antibiotic to treat bacterial or protozoal infections in poultry. The residues of DMZ cause harmful side effects in human beings. Thus, we have constructed a superior electrocatalyst for DMZ detection. A copper (Cu)-integrated poly(aniline) (PANI) electrocatalyst (PANI-Cu@BSA) was prepared by using a one-step method of biomimetic mineralization and polymerization using bovine serum albumin (BSA) as a stabilizer. Then, the synthesized PANI-Cu@BSA was encapsulated with reduced graphene oxide (rGO) using an ultrasonication method. The PANI-Cu@BSA/rGO nanocomposite had superior water dispersibility, high electrical conductivity, and nanoscale particles. Moreover, a PANI-Cu@BSA/rGO nanocomposite-modified, screen-printed carbon electrode was used for the sensitive electrochemical detection of DMZ. In phosphate buffer solution, the PANI-Cu@BSA/rGO/SPCE displayed a current intensity greater than PANI-Cu@BSA/SPCE, rGO/SPCE, and bare SPCE. This is because PANI-Cu@BSA combined with rGO increases fast electron transfer between the electrode and analyte, and this synergy results in analyte-electrode junctions with extraordinary conductivity and active surface areas. PANI-Cu@BSA/rGO/SPCE had a low detection limit, a high sensitivity, and a linear range of 1.78 nM, 5.96 μA μM-1 cm-2, and 0.79 to 2057 μM, respectively. The selective examination of DMZ was achieved with interfering molecules, and the PANI-Cu@BSA/rGO/SPCE showed excellent selectivity, stability, repeatability, and practicability.
Collapse
Affiliation(s)
- Kartik Behera
- Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan; (K.B.); (B.M.)
| | - Bhuvanenthiran Mutharani
- Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan; (K.B.); (B.M.)
| | - Yen-Hsiang Chang
- Department of General Dentistry, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan;
| | - Monika Kumari
- Institute of Cellular and Organismic Biology, Academia Sinica, Taipei 115, Taiwan;
| | - Fang-Chyou Chiu
- Department of Chemical and Materials Engineering, Chang Gung University, Taoyuan 333, Taiwan; (K.B.); (B.M.)
- Department of General Dentistry, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan;
| |
Collapse
|
2
|
Bej S, Nandi M, Ghosh P. Development of fluorophoric [2]pseudorotaxanes and [2]rotaxane: selective sensing of Zn(II). Org Biomol Chem 2022; 20:7284-7293. [PMID: 36052954 DOI: 10.1039/d2ob01210c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Fluorophoric [2]pseudorotaxanes {NiPR1(ClO4)2-NiPR3(ClO4)2} are synthesized by utilizing newly designed fluorophoric bidentate ligands (L1-L3) and a heteroditopic naphthalene containing macrocycle (NaphMC) with high yields via Ni(II) templation and π-π stacking interactions. Subsequently, a fluorophoric [2]rotaxane (NAPRTX) is established through a Cu(I) catalysed click reaction between an azide terminated pseudorotaxane, {NiPR4(ClO4)2}, which contains the newly designed fluorophoric ligand L4, and alkyne terminated bulky stopper units. All these fluorophoric [2]pseudorotaxanes and the [2]rotaxane were characterized using numerous techniques such as mass spectrometry, NMR, UV/Vis, PL, and elemental analysis, wherever applicable. Furthermore, to investigate the effect of the fluorophoric moieties, the coordinating ability of chelating units, and size and shape of the three dimensional cavity generated by the mechanical bond in the interlocked [2]rotaxane (NAPRTX), we have performed a sensing study of various metal ions. Thus, the interlocked [2]rotaxane is found to have potential as a selective fluorescent sensor for Zn(II) metal ions over other transition, alkali and alkaline earth metal ions, where the 2,2'-bipyridyl arylvinylene moiety of the axle acts as a fluorescence signalling unit.
Collapse
Affiliation(s)
- Somnath Bej
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A & 2B Raja S. C. Mullick Road, Kolkata 700032, India.
| | - Mandira Nandi
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A & 2B Raja S. C. Mullick Road, Kolkata 700032, India.
| | - Pradyut Ghosh
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A & 2B Raja S. C. Mullick Road, Kolkata 700032, India.
| |
Collapse
|
3
|
Ferretti CA, Gutierrez LG, Guntero VA, Noriega PJ, Kneeteman MN. A selective colorimetric chemosensor for detection of Cu(II) ions in aqueous samples. CR CHIM 2021. [DOI: 10.5802/crchim.131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
4
|
DFT study of iminodiacetic acid functionalised polyaniline copolymer interaction with heavy metal ions through binding energy, stability constant and charge transfer calculations. COMPUT THEOR CHEM 2021. [DOI: 10.1016/j.comptc.2021.113288] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
5
|
A basket-type fluorescent sensor based calix[4]azacrown ether for multi-analytes: Practicability in living cells and real sample. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106279] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
New Concept for the Study of the Fluid Dynamics of Lithium Extraction Using Calix[4]arene Derivatives in T-Type Microreactor Systems. SEPARATIONS 2021. [DOI: 10.3390/separations8050070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Lithium extraction remains a challenge in the hydrometallurgy process due to its economic value and maldistribution sources. Employing calix[4]arene derivatives in solvent extraction techniques results in high selectivity and extraction capability, but a slow extraction rate. The slow kinetics of batch-wise extraction can be drastically accelerated by using a T-type microreactor system. Therefore, a combination of calix[4]arene and a microreactor system serves as an ideal platform for efficient lithium extraction. In this work, the fluid dynamics of lithium extraction using a monoacetic acid calix[4]arene derivative in a T-type microreactor system were studied. Increasing the O/A ratio increases the average length, surface area, and volume of the organic droplets, but decreases the specific surface area. In contrast, increasing the Reynolds number decreases the average length, surface area, and volume of the organic droplets, but increases the specific surface area. It was found that shorter diffusion distance, larger specific surface area, and faster vortex velocity were the factors that play the most pivotal roles in achieving great extraction rate enhancement in T-type microreactor systems compared to batch-wise systems. These findings represent an important new concept in the study of the fluid dynamics of lithium extraction using monoacetic acid calix[4]arene derivatives in T-type microreactor systems.
Collapse
|
7
|
Bej S, Nandi M, Ghosh P. A Cd(ii) and Zn(ii) selective naphthyl based [2]rotaxane acts as an exclusive Zn(ii) sensor upon further functionalization with pyrene. Dalton Trans 2021; 50:294-303. [PMID: 33300925 DOI: 10.1039/d0dt03645e] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A new multi-functional [2]rotaxane, ROTX, has been synthesized via a Cu(i) catalysed azide-alkyne cycloaddition reaction between Ni(ii) templated azide terminated pseudorotaxane composed of a naphthalene based heteroditopic wheel, NaphMC, and an alkyne terminated stopper. Subsequently, ROTX has been functionalized with pyrene moieties to develop a bifluorophoric [2]rotaxane, PYROTX, having naphthalene and pyrene moieties. Detailed characterization of these two rotaxanes is performed by utilizing several techniques such as ESI-MS, (1D and 2D) NMR, UV/Vis and PL studies. Comparative metal ion sensing studies of NaphMC (a fluorophoric cyclic receptor), ROTX ([2]rotaxane with a naphthyl fluorophore) and PYROTX ([2]rotaxane having naphthyl and pyrene fluorophores) have been performed to determine the effect of dimensionality/functionalization on the metal ion selectivity. Although NaphMC fails to discriminate between metal ions, ROTX serves as a selective sensor for Zn(ii) and Cd(ii). Importantly, PYROTX shows exclusive selectivity towards Zn(ii) over various transition, alkali and alkaline earth metal ions including Cd(ii).
Collapse
Affiliation(s)
- Somnath Bej
- School of Chemical Sciences, Indian Association for the Cultivation of Science, 2A & 2B Raja S. C. Mullick Road, Kolkata 700032, India.
| | | | | |
Collapse
|
8
|
Gassoumi B, Ghalla H, Chaabane RB. Host-guest complexation studies of NO 3, NO 2, CO 2, and N 2 gas with the calix[4]arene molecule. J Mol Model 2020; 26:149. [PMID: 32444916 DOI: 10.1007/s00894-020-04416-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 05/09/2020] [Indexed: 01/31/2023]
Abstract
Calix[n]arenes (abbreviated as CX[n]) are the macro-molecules based on phenol groups with a hydrophobic cavity to encapsulate a gas or small molecules. They are used as molecular vehicles. For instance, these molecules are used in the activation of the solubility of monomers in the specific media and in pharmaceutical drug delivery. The limit of the development of gaseous pollutants will be a vital subject in the future. The polluting gases NO3, NO2, CO2, N2, etc., need cage molecules, such as CX[4], to be encapsulated. In this report, the red shift of the H-bonding interactions of the CX[4]-gas (by adding the gas inside or outside the cavity) is clearly explained by the vibrational analysis. The electronic spectra of the complexes of CX[4] with NO3, NO2, CO2, and N2) exhibit a blue-shift pick in comparison with the ones observed for the CX[4] molecule. The electrophilic and nucleophilic sites of the stable host-guest have been investigated. Additionally, the non-covalent interactions have been calculated based on the reduced density gradient RDG and QTAIM theory.
Collapse
Affiliation(s)
- Bouzid Gassoumi
- Laboratory of Advanced Materials and Interfaces (LIMA), Faculty of Science of Monastir, University of Monastir, Avenue of Environment, 5000, Monastir, Tunisia. .,Institute of Light and Matter, UMR 5306 University of Lyon 1-CNRS, University of Lyon, 69622, Villeurbanne cedex, France.
| | - Houcine Ghalla
- Quantum and Statistical Physics Laboratory, Faculty of Science, University of Monastir, 5079, Monastir, Tunisia
| | - Rafik Ben Chaabane
- Laboratory of Advanced Materials and Interfaces (LIMA), Faculty of Science of Monastir, University of Monastir, Avenue of Environment, 5000, Monastir, Tunisia.
| |
Collapse
|
9
|
Vyas G, Bhatt S, Si MK, Jindani S, Suresh E, Ganguly B, Paul P. Colorimetric dual sensor for Cu(II) and tyrosine and its application as paper strips for detection in water and human saliva as real samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 230:118052. [PMID: 31955120 DOI: 10.1016/j.saa.2020.118052] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 01/07/2020] [Accepted: 01/09/2020] [Indexed: 06/10/2023]
Abstract
A calix[4]arene based compound incorporating amide and morpholine moieties has been synthesized and its ion recognition property towards metal ions and application of its metal complex towards sensing of amino acids has been investigated. The synthesized compound interacts with Cu2+ with high selectivity and sensitivity (LOD, 0.1 ppb) in aqueous media with instant color change from colorless to yellow without interference from any other metal ions used in this study. The molecular structure of the calix compound (1) has been determined by single crystal X-ray study and the structure of its Cu2+ complex has been established by DFT calculation. The Cu2+ complex of 1 selectively detects tyrosine (LOD, 1.2 ppm) in water with distinct color change and without any interference from other 22 amino acids used in this study. The mechanism for detection of tyrosine with color change is also presented. For easy field application, paper based sensor strips have been prepared by coating compound 1 and its Cu2+ complex on filter paper, which have been used for semi-quantitative measurement of Cu2+ and tyrosine. Compound 1 and its Cu2+ complex have also been used for detection of Cu2+ and tyrosine, respectively in water and human saliva as real samples and satisfactory results are obtained.
Collapse
Affiliation(s)
- Gaurav Vyas
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Shreya Bhatt
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Mrinal K Si
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Sana Jindani
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Eringathodi Suresh
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Bishwajit Ganguly
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India.
| | - Parimal Paul
- Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar 364002, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India.
| |
Collapse
|
10
|
Ramachandran M, Anandan S, Ashokkumar M. A luminescent on–off probe based calix[4]arene linked through triazole with ruthenium(ii) polypyridine complexes to sense copper(ii) and sulfide ions. NEW J CHEM 2019. [DOI: 10.1039/c9nj01632e] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The supramolecular sensor Ru2L was designed by joining a bis-ruthenium(ii) polypyridyl complex with a p-tert-butyl calix[4]arene platform through a 1,2,3-triazole linker and used for sensing of copper(ii) and sulfide ions by fluorescence.
Collapse
Affiliation(s)
| | - Sambandam Anandan
- Department of Chemistry
- National Institute of Technology
- Tiruchirappalli-620 015
- India
| | | |
Collapse
|
11
|
Patra S, Boricha VP, Paul P. Dual-Mode Calixarene-Based Chemosensor: Highly Selective Fluorogenic Detection of Hg2+
and Chromogenic Detection of Cu2+
with a Single Ionophore. Eur J Inorg Chem 2018. [DOI: 10.1002/ejic.201800925] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Subrata Patra
- Analytical and Environmental Science Division & Centralized Instrument Facility; CSIR-Central Salt and Marine Chemicals Research Institute; G. B. Marg 364002 Bhavnagar India
- Department of Chemistry; Marwadi University; -360007 Rajkot Gujarat India
| | - Vinod P. Boricha
- Analytical and Environmental Science Division & Centralized Instrument Facility; CSIR-Central Salt and Marine Chemicals Research Institute; G. B. Marg 364002 Bhavnagar India
| | - Parimal Paul
- Analytical and Environmental Science Division & Centralized Instrument Facility; CSIR-Central Salt and Marine Chemicals Research Institute; G. B. Marg 364002 Bhavnagar India
| |
Collapse
|
12
|
Kanellis VG. Sensitivity limits of biosensors used for the detection of metals in drinking water. Biophys Rev 2018; 10:1415-1426. [PMID: 30225681 PMCID: PMC6233349 DOI: 10.1007/s12551-018-0457-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Accepted: 09/10/2018] [Indexed: 12/13/2022] Open
Abstract
Even when present in very low concentrations, certain metal ions can have significant health impacts depending on their concentration when present in drinking water. In an effort to detect and identify trace amounts of such metals, environmental monitoring has created a demand for new and improved methods that have ever-increasing sensitivities and selectivity. This paper reviews the sensitivities of over 100 recently published biosensors using various analytical techniques such as fluorescence, voltammetry, inductively coupled plasma techniques, spectrophotometry and visual colorimetric detection that display selectivity for copper, cadmium, lead, mercury and/or aluminium in aqueous solutions.
Collapse
|
13
|
Gao W, Li H, Pu S. A highly selective fluorescent probe for Cu2+ based on a diarylethene with a benzo[1,2,5]oxadiazol-4-ylamine Schiff base unit. J Photochem Photobiol A Chem 2018. [DOI: 10.1016/j.jphotochem.2018.06.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
14
|
Liu Y, Zhao Z, Liu Q. Preparation of Macrometallocycle and Selective Sensor for Copper Ion. Sci Rep 2018; 8:10943. [PMID: 30026519 PMCID: PMC6053464 DOI: 10.1038/s41598-018-29356-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Accepted: 07/09/2018] [Indexed: 12/15/2022] Open
Abstract
Two bis-imidazolium salts 1,8-bis[2'-(N-R-imidazoliumyl)acetylamino]naphthalene chloride (L1H4·Cl2: R = Et; L2H4·Cl2: R = nBu), as well as their four NHC metal complexes [L1H2Ag]Cl (1), [L1Ni] (2), [L2Ni] (3) and [L1H2Hg(HgCl4)] (4) have been synthesized. In each of the cationic moieties of complexes 1 or 4, there is a groove-like 14-membered macrometallocycle, and each macrometallocycle is consisted of one biscarbene ligand L1H2 and one metal ion (silver(I) ion for 1 and mercury(II) ion for 4). Three 6-membered cycles are contained in each molecule of complexes 2 or 3. Additionally, the selective recognition of macrometallocycle 1 for Cu2+ was studied with the methods of fluorescence and ultraviolet spectroscopy, 1H NMR titrations, MS and IR spectra. The experimental results display macrometallocycle 1 can discriminate Cu2+ from other cations effectively.
Collapse
Affiliation(s)
- Yingjie Liu
- Tianjin Key Laboratory of Process Measurement and Control, Institute of Robotics and Autonomous Systems, Tianjin University, Tianjin, 300072, China
| | - Zhixiang Zhao
- Key Laboratory of Inorganic-Organic Hybrid Functional Materials Chemistry (Tianjin Normal University), Ministry of Education; Tianjin Key Laboratory of Structure and Performance for Functional Molecules, College of Chemistry, Tianjin Normal University, Tianjin, 300387, China
| | - Qingxiang Liu
- Key Laboratory of Inorganic-Organic Hybrid Functional Materials Chemistry (Tianjin Normal University), Ministry of Education; Tianjin Key Laboratory of Structure and Performance for Functional Molecules, College of Chemistry, Tianjin Normal University, Tianjin, 300387, China.
| |
Collapse
|