1
|
Perry AN, Jarosova R, Witt CE, Weese-Myers ME, Subedi V, Ross AE. Plasma-treated gold microelectrodes for subsecond detection of Zn(II) with fast-scan cyclic voltammetry. Analyst 2024; 149:4643-4652. [PMID: 39136087 DOI: 10.1039/d4an00307a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/10/2024]
Abstract
The sensitivity of zinc (Zn(II)) detection using fast-scan cyclic voltammetry (FSCV) with carbon fiber microelectrodes (CFMEs) is low compared to other neurochemicals. We have shown previously that Zn(II) plates to the surface of CFME's and we speculate that it is because of the abundance of oxide functionality on the surface. Plating reduces sensitivity over time and causes significant disruption to detection stability. This limited sensitivity and stability hinders Zn(II) detection, especially in complex matrices like the brain. To address this, we developed plasma-treated gold fiber microelectrodes (AuMEs) which enable sensitive and stable Zn(II) detection with FSCV. Typically, gold fibers are treated using corrosive acids to clean the surface and this step is important for preparing the surface for electrochemistry. Likewise, because FSCV is an adsorption-based technique, it is also important for Zn(II) to adsorb and desorb to prevent irreversible plating. Because of these requirements, careful optimization of the electrode surface was necessary to render the surface for Zn(II) adsorption yet strike a balance between attraction to the surface vs. irreversible interactions. In this study, we employed oxygen plasma treatment to activate the gold fiber surface without inducing significant morphological changes. This treatment effectively removes the organic layer while functionalizing the surface with oxygen, enabling Zn(II) detection that is not possible on untreated gold surfaces. Our results demonstrate significantly improved Zn(II) detection sensitivity and stability on AuME compared to CFME's. Overall, this work provides an advance in our understanding of Zn(II) electrochemistry and a new tool for improved metallotransmitter detection in the brain.
Collapse
Affiliation(s)
- Anntonette N Perry
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Office# 418A Rieveschl, Cincinnati, OH 45221-0172, USA.
| | - Romana Jarosova
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Office# 418A Rieveschl, Cincinnati, OH 45221-0172, USA.
| | - Colby E Witt
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Office# 418A Rieveschl, Cincinnati, OH 45221-0172, USA.
| | - Moriah E Weese-Myers
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Office# 418A Rieveschl, Cincinnati, OH 45221-0172, USA.
| | - Vivek Subedi
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Office# 418A Rieveschl, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Office# 418A Rieveschl, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
2
|
Delong LM, Witt CE, Pennell M, Ross AE. A microfluidic chip for sustained oxygen gradient formation in the intestine ex vivo. LAB ON A CHIP 2024; 24:1918-1929. [PMID: 38372633 PMCID: PMC10998727 DOI: 10.1039/d3lc00793f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/20/2024]
Abstract
The oxygen gradient across the intestine influences intestinal physiology and the microbial environment of the microbiome. The microbiome releases metabolites that communicate with enterochromaffin cells, neuronal cells, and resident immune cells to facilitate the bidirectional communication across the gut-brain axis. Measuring communication between various cell types within the intestine could provide essential information about key regulators of gut and brain health; however, the microbial environment of the intestine is heavily dependent on the physiological oxygen gradient that exists across the intestinal wall. Likewise, there exist a need for methods which enable real-time monitoring of intestinal signaling ex vivo yet this remains challenging due to the inability to adequately culture intestinal tissue ex vivo while also exposing the appropriate locations of the intestine for probe insertion and monitoring. Here, we designed and fabricated a 3D printed microfluidic device to maintain the oxygen gradient across precision cut murine intestinal slices with the capability to couple to external neurochemical recording techniques. The gradient is maintained from outlets below while allowing access to the slice from above for detection with fast scan cyclic voltammetry (FSCV) and carbon-fiber microelectrodes. A series of 11 outlet ports were designed to lay underneath the slice which were connected to channels to deliver oxygenated vs. deoxygenated media. Outlet ports were designed in an oval shape where deoxygenated media was delivered to the center of the slice and oxygenated media is delivered to the outer portion of the slice to mimic the location of oxygen across the intestine. An oxygen sensitive fluorescent dye, tris(2,2'-bipyridyl)dichlororuthenium(II), was used to characterize the tunability of the gradient. Viability of the tissue was confirmed by both fluorescence microscopy and FSCV. Additionally, we measured simultaneous serotonin and melatonin signaling with FSCV in the intestine for the first time. Overall, this chip provides a significant advance in our ability to culture intestinal slices ex vivo with the added benefit of direct access for measurements and imaging.
Collapse
Affiliation(s)
- Lauren M Delong
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Colby E Witt
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Madison Pennell
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
3
|
Si X, Dai S, Fang Y, Tang J, Wang Z, Li Y, Song Z, Chen Y, Liu Y, Zhao G, Zhang B, Pu J. Matrix metalloproteinase-9 inhibition prevents aquaporin-4 depolarization-mediated glymphatic dysfunction in Parkinson's disease. J Adv Res 2024; 56:125-136. [PMID: 36940850 PMCID: PMC10834796 DOI: 10.1016/j.jare.2023.03.004] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 01/31/2023] [Accepted: 03/14/2023] [Indexed: 03/23/2023] Open
Abstract
INTRODUCTION The glymphatic system offers a perivascular pathway for the clearance of pathological proteins and metabolites to optimize neurological functions. Glymphatic dysfunction plays a pathogenic role in Parkinson's disease (PD); however, the molecular mechanism of glymphatic dysfunction in PD remains elusive. OBJECTIVE To explore whether matrix metalloproteinase-9 (MMP-9)-mediated β-dystroglycan (β-DG) cleavage is involved in the regulation of aquaporin-4 (AQP4) polarity-mediated glymphatic system in PD. METHODS 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-induced PD and A53T mice were used in this study. The glymphatic function was evaluated using ex vivo imaging. TGN-020, an AQP4 antagonist, was administered to investigate the role of AQP4 in glymphatic dysfunction in PD. GM6001, an MMP-9 antagonist, was administered to investigate the role of the MMP-9/β-DG pathway in regulating AQP4. The expression and distribution of AQP4, MMP-9, and β-DG were assessed using western blotting, immunofluorescence, and co-immunoprecipitation. The ultrastructure of basement membrane (BM)-astrocyte endfeet was detected using transmission electron microscopy. Rotarod and open-field tests were performed to evaluate motor behavior. RESULTS Perivascular influx and efflux of cerebral spinal fluid tracers were reduced in MPTP-induced PD mice with impaired AQP4 polarization. AQP4 inhibition aggravated reactive astrogliosis, glymphatic drainage restriction, and dopaminergic neuronal loss in MPTP-induced PD mice. MMP-9 and cleaved β-DG were upregulated in both MPTP-induced PD and A53T mice, with reduced polarized localization of β-DG and AQP4 to astrocyte endfeet. MMP-9 inhibition restored BM-astrocyte endfeet-AQP4 integrity and attenuated MPTP-induced metabolic perturbations and dopaminergic neuronal loss. CONCLUSION AQP4 depolarization contributes to glymphatic dysfunction and aggravates PD pathologies, and MMP-9-mediated β-DG cleavage regulates glymphatic function through AQP4 polarization in PD, which may provide novel insights into the pathogenesis of PD.
Collapse
Affiliation(s)
- Xiaoli Si
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China; Department of Neurology, The Fourth Affiliated Hospital, International Institutes of Medicine, Zhejiang University, School of Medicine, Yiwu, Zhejiang 322000, China
| | - Shaobing Dai
- Department of Anesthesiology, Women's Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Yi Fang
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Jiahui Tang
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Zhiyun Wang
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Yaolin Li
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Zhe Song
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Ying Chen
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Yi Liu
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China
| | - Guohua Zhao
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China; Department of Neurology, The Fourth Affiliated Hospital, International Institutes of Medicine, Zhejiang University, School of Medicine, Yiwu, Zhejiang 322000, China.
| | - Baorong Zhang
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China.
| | - Jiali Pu
- Department of Neurology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310009, China.
| |
Collapse
|
4
|
Ostertag BJ, Ross AE. Editors' Choice-Review-The Future of Carbon-Based Neurochemical Sensing: A Critical Perspective. ECS SENSORS PLUS 2023; 2:043601. [PMID: 38170109 PMCID: PMC10759280 DOI: 10.1149/2754-2726/ad15a2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/06/2023] [Indexed: 01/05/2024]
Abstract
Carbon-based sensors have remained critical materials for electrochemical detection of neurochemicals, rooted in their inherent biocompatibility and broad potential window. Real-time monitoring using fast-scan cyclic voltammetry has resulted in the rise of minimally invasive carbon fiber microelectrodes as the material of choice for making measurements in tissue, but challenges with carbon fiber's innate properties have limited its applicability to understudied neurochemicals. Here, we provide a critical review of the state of carbon-based real-time neurochemical detection and offer insight into ways we envision addressing these limitations in the future. This piece focuses on three main hinderances of traditional carbon fiber based materials: diminished temporal resolution due to geometric properties and adsorption/desorption properties of the material, poor selectivity/specificity to most neurochemicals, and the inability to tune amorphous carbon surfaces for specific interfacial interactions. Routes to addressing these challenges could lie in methods like computational modeling of single-molecule interfacial interactions, expansion to tunable carbon-based materials, and novel approaches to synthesizing these materials. We hope this critical piece does justice to describing the novel carbon-based materials that have preceded this work, and we hope this review provides useful solutions to innovate carbon-based material development in the future for individualized neurochemical structures.
Collapse
Affiliation(s)
- Blaise J. Ostertag
- University of Cincinnati, Department of Chemistry, Cincinnati, Ohio 45221-0172, United States of America
| | - Ashley E. Ross
- University of Cincinnati, Department of Chemistry, Cincinnati, Ohio 45221-0172, United States of America
| |
Collapse
|
5
|
Jarosova R, Ostertag BJ, Ross AE. Graphene oxide fiber microelectrodes with controlled sheet alignment for sensitive neurotransmitter detection. NANOSCALE 2023; 15:15249-15258. [PMID: 37672207 DOI: 10.1039/d3nr02879h] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/07/2023]
Abstract
Here, we synthesized and characterized graphene oxide (GO) fiber microelectrodes with controllable nanosheet orientation to study the extent to which sheet alignment and orientation impacts electrochemical detection of neurochemicals. The alignment of the GO nanosheets was characterized by scanning electron microscopy, Raman spectroscopy, and cyclic voltammetry. The electrochemical performance of GO microelectrodes and its suitability for subsecond detection of neurotransmitters was further evaluated by fast-scan cyclic voltammetry (FSCV). We have shown that the GO sheet alignment has a considerable effect on the electron transfer kinetics, frequency independent behavior, and detection suitability for specific neurotransmitters. Therefore, this fine-tuning aspect of the electrode surface for specific electrochemical detection should be taken into consideration for any future utilization of GO-based biological sensors.
Collapse
Affiliation(s)
- Romana Jarosova
- University of Cincinnati, Department of Chemistry, 312 College Dr, 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Blaise J Ostertag
- University of Cincinnati, Department of Chemistry, 312 College Dr, 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr, 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
6
|
Weese-Myers ME, Cryan MT, Witt CE, Caldwell KCN, Modi B, Ross AE. Dynamic and Rapid Detection of Guanosine during Ischemia. ACS Chem Neurosci 2023; 14:1646-1658. [PMID: 37040534 PMCID: PMC10265669 DOI: 10.1021/acschemneuro.3c00048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/13/2023] Open
Abstract
Guanosine acts in both neuroprotective and neurosignaling pathways in the central nervous system; in this paper, we present the first fast voltammetric measurements of endogenous guanosine release during pre- and post-ischemic conditions. We discuss the metric of our measurements via analysis of event concentration, duration, and interevent time of rapid guanosine release. We observe changes across all three metrics from our normoxic to ischemic conditions. Pharmacological studies were performed to confirm that guanosine release is a calcium-dependent process and that the signaling observed is purinergic. Finally, we show the validity of our ischemic model via staining and fluorescent imaging. Overall, this paper sets the tone for rapid monitoring of guanosine and provides a platform to investigate the extent to which guanosine accumulates at the site of brain injury, i.e., ischemia.
Collapse
Affiliation(s)
- Moriah E. Weese-Myers
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172
- Co-first author
| | - Michael T. Cryan
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172
- Co-first author
| | - Colby E. Witt
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172
| | - Kaejaren C. N. Caldwell
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172
| | - Bindu Modi
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172
| | - Ashley E. Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172
| |
Collapse
|
7
|
Hassan Q, Riley C, Noroozifar M, Kerman K. Hybrid Nanomaterial of Graphene Oxide Quantum Dots with Multi-Walled Carbon Nanotubes for Simultaneous Voltammetric Determination of Four DNA Bases. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:nano13091509. [PMID: 37177060 PMCID: PMC10180489 DOI: 10.3390/nano13091509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 04/19/2023] [Accepted: 04/25/2023] [Indexed: 05/15/2023]
Abstract
In this proof-of-concept study, a novel hybrid nanomaterial-based electrochemical sensor was developed for the simultaneous detection of four DNA bases. For the modification of the working electrode surface, graphene oxide quantum dots (GOQDs) were synthesized using a solvothermal method. GOQDs were then used for the preparation of a hybrid nanomaterial with multi-walled carbon nanotubes (GOQD-MWCNT) using a solvothermal technique for the first time. Transmission electron microscopy (TEM) was used to characterize the GOQDs-MWCNTs. A glassy carbon electrode (GCE) was modified with the GOQDs-MWCNTs using Nafion™ to prepare a GOQD-MWCNT/GCE for the simultaneous determination of four DNA bases in phosphate buffer solution (PBS, pH 7.0) using differential pulse voltammetry (DPV). The calibration plots were linear up to 50, 50, 500, and 500 µM with a limit of detection at 0.44, 0.2, 1.6, and 5.6 µM for guanine (G), adenine (A), thymine (T) and cytosine (C), respectively. The hybrid-modified sensor was used for the determination of G, A, T, and C spiked in the artificial saliva samples with the recovery values ranging from 95.9 to 106.8%. This novel hybrid-modified electrochemical sensor provides a promising platform for the future development of a device for cost-effective and efficient simultaneous detection of DNA bases in real biological and environmental samples.
Collapse
Affiliation(s)
- Qusai Hassan
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada
| | - Chevon Riley
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada
| | - Meissam Noroozifar
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada
| | - Kagan Kerman
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, ON M1C 1A4, Canada
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, ON M5S 3H6, Canada
| |
Collapse
|
8
|
Ostertag B, Ross AE. Wet-Spun Porous Carbon Microfibers for Enhanced Electrochemical Detection. ACS APPLIED MATERIALS & INTERFACES 2023; 15:17601-17611. [PMID: 36989172 PMCID: PMC10316334 DOI: 10.1021/acsami.3c00423] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We present a novel copolymer-based, uniform porous carbon microfiber (PCMF) formed via wet-spinning for significantly improved electrochemical detection. Carbon fiber (CF), fabricated from a polyacrylonitrile (PAN) precursor, is commonly used in batteries or for electrochemical detection of neurochemicals due to its biplanar geometry and desirable edge plane sites with high surface free energy and defects for enhanced analyte interactions. Recently, the presence of pores within carbon materials has presented interesting electrochemistry leading to detection improvements; however, there is currently no method to uniformly create pores on a carbon microfiber surface impacting a broad range of electrochemical applications. Here, we synthesized controllable porous carbon fibers from a spinning dope of the copolymers PAN and poly(methyl methacrylate) (PMMA) in dimethylformamide via wet spinning for the first time. PMMA serves as a sacrificial block introducing macropores of increased edge-plane character on the fiber. Methods were optimized to produce porous CFs at similar dimensions to traditional CF. We prove that an increase in porosity enhances the degree of disorder on the surface, resulting in significantly improved detection capabilities with fast-scan cyclic voltammetry. Local trapping of analytes at porous geometries enables electrochemical reversibility with improved sensitivity, linear range of detection, and measurement temporal resolution. Overall, we demonstrate the utility of a copolymer synthetic method for PCMF fabrication, providing a stable, controlled macroporous fiber framework with enhanced edge plane character. This work will significantly advance fundamental investigations of how pores and edge plane sites influence electrochemical detection.
Collapse
Affiliation(s)
- Blaise Ostertag
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Ashley E. Ross
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| |
Collapse
|
9
|
Tjahjono N, Jin Y, Hsu A, Roukes M, Tian L. Letting the little light of mind shine: Advances and future directions in neurochemical detection. Neurosci Res 2022; 179:65-78. [PMID: 34861294 PMCID: PMC9508992 DOI: 10.1016/j.neures.2021.11.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 11/29/2021] [Indexed: 12/12/2022]
Abstract
Synaptic transmission via neurochemical release is the fundamental process that integrates and relays encoded information in the brain to regulate physiological function, cognition, and emotion. To unravel the biochemical, biophysical, and computational mechanisms of signal processing, one needs to precisely measure the neurochemical release dynamics with molecular and cell-type specificity and high resolution. Here we reviewed the development of analytical, electrochemical, and fluorescence imaging approaches to detect neurotransmitter and neuromodulator release. We discussed the advantages and practicality in implementation of each technology for ease-of-use, flexibility for multimodal studies, and challenges for future optimization. We hope this review will provide a versatile guide for tool engineering and applications for recording neurochemical release.
Collapse
Affiliation(s)
- Nikki Tjahjono
- Biomedical Engineering Graduate Group, University of California, Davis, Davis, CA, 95616, USA
| | - Yihan Jin
- Neuroscience Graduate Group, University of California, Davis, Davis, CA, 95618, USA
| | - Alice Hsu
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Michael Roukes
- Department of Physics, California Institute of Technology, Pasadena, CA, 91125, USA
| | - Lin Tian
- Department of Biochemistry and Molecular Medicine, School of Medicine, University of California, Davis, Davis, CA, 95616, USA.
| |
Collapse
|
10
|
Li Y, Keller AL, Cryan MT, Ross AE. Metal Nanoparticle Modified Carbon-Fiber Microelectrodes Enhance Adenosine Triphosphate Surface Interactions with Fast-Scan Cyclic Voltammetry. ACS MEASUREMENT SCIENCE AU 2022; 2:96-105. [PMID: 35479102 PMCID: PMC9026253 DOI: 10.1021/acsmeasuresciau.1c00026] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 09/21/2021] [Accepted: 09/22/2021] [Indexed: 05/08/2023]
Abstract
Adenosine triphosphate (ATP) is an important rapid signaling molecule involved in a host of pathologies in the body. Historically, ATP is difficult to directly detect electrochemically with fast-scan cyclic voltammetry (FSCV) due to limited interactions at bare carbon-fibers. Systematic investigations of how ATP interacts at electrode surfaces is necessary for developing more sensitive electrochemical detection methods. Here, we have developed gold nanoparticle (AuNP), and platinum nanoparticle (PtNP) modified carbon-fiber microelectrodes coupled to FSCV to measure the extent to which ATP interacts at metal nanoparticle-modified surfaces and to improve the sensitivity of direct electrochemical detection. AuNP and PtNPs were electrodeposited on the carbon-fiber surface by scanning from -1.2 to 1.5 V for 30 s in 0.5 mg/mL HAuCl4 or 0.5 mg/mLK2PtCl6. Overall, we demonstrate an average 4.1 ± 1.0-fold increase in oxidative ATP current at AuNP-modified and a 3.5 ± 0.3-fold increase at PtNP-modified electrodes. Metal nanoparticle-modified surfaces promoted improved electrocatalytic conversion of ATP oxidation products at the surface, facilitated enhanced adsorption strength and surface coverage, and significantly improved sensitivity. ATP was successfully detected within living murine lymph node tissue following exogenous application. Overall, this study demonstrates a detailed characterization of ATP oxidation at metal nanoparticle surfaces and a significantly improved method for direct electrochemical detection of ATP in tissue.
Collapse
|
11
|
Syeed AJ, Li Y, Ostertag BJ, Brown JW, Ross AE. Nanostructured carbon-fiber surfaces for improved neurochemical detection. Faraday Discuss 2022; 233:336-353. [PMID: 34935021 PMCID: PMC9125946 DOI: 10.1039/d1fd00049g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Fundamental insight into the extent to which the nanostructured surface and geometry impacts neurochemical interactions at electrode surfaces could provide significant advances in our ability to design and fabricate ultrasensitive neurochemical detection probes. Here, we investigate the extent to which the nanostructure of the carbon-fiber surface impacts detection of catecholamines and purines with fast-scan cyclic voltammetry (FSCV). Carbon-fibers were treated with argon (Ar) plasma to induce variations in the nano- and micro-structure without changing the functionalization of the surface. We tested variations in topology by measuring the extent to which the flow rate, RF power, and treatment time affect the surface roughness. Flow rates from 50-100 sccm, plasma power from 20-100 W, and treatment times from 30 s to 5 min were compared. Two Ar-treatments were chosen from the optimization studies for comparison, and the surface roughness was evaluated using atomic force microscopy (AFM). To ensure no changes in chemical composition, fibers were analyzed with X-ray photoelectron spectroscopy (XPS). On average, at the optimized Ar-plasma treatment procedure, oxidative current for adenosine and ATP increased by 3.5 ± 1.4-fold and 3.2 ± 0.6-fold, and guanosine and GTP by 1.7 ± 0.3-fold and 1.8 ± 0.3-fold, respectively (n = 9). Dopamine increased by 1.7 ± 0.3-fold. The extent to which changes in the electrode structure impact adsorption, sensitivity, and electron transfer rates were measured. A COMSOL Multiphysics simulation was developed to enable the modeling of mass transport of electroactive species at varying electrode geometries. Overall, this study provides critical insight into the extent to which the nanostructure of the surface impacts the electrochemical detection of neurochemicals.
Collapse
Affiliation(s)
- Ayah J Syeed
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Yuxin Li
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Blaise J Ostertag
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Jared W Brown
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
12
|
Li Y, Jarosova R, Weese-Myers ME, Ross AE. Graphene-Fiber Microelectrodes for Ultrasensitive Neurochemical Detection. Anal Chem 2022; 94:4803-4812. [PMID: 35274933 DOI: 10.1021/acs.analchem.1c05637] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Here, we have synthesized and characterized graphene-fiber microelectrodes (GFME's) for subsecond detection of neurochemicals with fast-scan cyclic voltammetry (FSCV) for the first time. GFME's exhibited extraordinary properties including faster electron transfer kinetics, significantly improved sensitivity, and ease of tunability that we anticipate will have major impacts on neurochemical detection for years to come. GF's have been used in the literature for various applications; however, scaling their size down to microelectrodes and implementing them as neurochemical microsensors is significantly less developed. The GF's developed in this paper were on average 20-30 μm in diameter and both graphene oxide (GO) and reduced graphene oxide (rGO) fibers were characterized with FSCV. Neat GF's were synthesized using a one-step dimension-confined hydrothermal strategy. FSCV detection has traditionally used carbon-fiber microelectrodes (CFME's) and more recently carbon nanotube fiber electrodes; however, uniform functionalization and direct control of the 3D surface structure of these materials remain limited. The expansion to GFME's will certainly open new avenues for fine-tuning the electrode surface for specific electrochemical detection. When comparing to traditional CFME's, our GFME's exhibited significant increases in electron transfer, redox cycling, fouling resistance, higher sensitivity, and frequency independent behavior which demonstrates their incredible utility as biological sensors.
Collapse
Affiliation(s)
- Yuxin Li
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Romana Jarosova
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Moriah E Weese-Myers
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Ashley E Ross
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| |
Collapse
|
13
|
Ostertag BJ, Cryan MT, Serrano JM, Liu G, Ross AE. Porous Carbon Nanofiber-Modified Carbon Fiber Microelectrodes for Dopamine Detection. ACS APPLIED NANO MATERIALS 2022; 5:2241-2249. [PMID: 36203493 PMCID: PMC9531868 DOI: 10.1021/acsanm.1c03933] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
We present a method to modify carbon-fiber microelectrodes (CFME) with porous carbon nanofibers (PCFs) to improve detection and to investigate the impact of porous geometry for dopamine detection with fast-scan cyclic voltammetry (FSCV). PCFs were fabricated by electrospinning, carbonizing, and pyrolyzing poly(acrylonitrile)-b-poly(methyl methacrylate) (PAN-b-PMMA) block copolymer nanofiber frameworks. Commonly, porous nanofibers are used for energy storage applications, but we present an application of these materials for biosensing which has not been previously studied. This modification impacted the topology and enhanced redox cycling at the surface. PCF modifications increased the oxidative current for dopamine 2.0 ± 0.1-fold (n = 33) with significant increases in detection sensitivity. PCF are known to have more edge plane sites which we speculate lead to the two-fold increase in electroactive surface area. Capacitive current changes were negligible providing evidence that improvements in detection are due to faradaic processes at the electrode. The ΔEp for dopamine decreased significantly at modified CFMEs. Only a 2.2 ± 2.2 % change in dopamine current was observed after repeated measurements and only 10.5 ± 2.8% after 4 hours demonstrating the stability of the modification over time. We show significant improvements in norepinephrine, ascorbic acid, adenosine, serotonin, and hydrogen peroxide detection. Lastly, we demonstrate that the modified electrodes can detect endogenous, unstimulated release of dopamine in living slices of rat striatum. Overall, we provide evidence that porous nanostructures significantly improve neurochemical detection with FSCV and echo the necessity for investigating the extent to which geometry impacts electrochemical detection.
Collapse
Affiliation(s)
- Blaise J. Ostertag
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Michael T. Cryan
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Joel M. Serrano
- Virginia Polytechnic Institute and State University, Department of Chemistry, Macromolecules Innovation Institute, Division of Nanoscience, Academy of Integrated Science, 800 West Campus Dr., Blacksburg, VA, 2406, USA
| | - Guoliang Liu
- Virginia Polytechnic Institute and State University, Department of Chemistry, Macromolecules Innovation Institute, Division of Nanoscience, Academy of Integrated Science, 800 West Campus Dr., Blacksburg, VA, 2406, USA
| | - Ashley E. Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
- Corresponding author: Office Phone#: 513-556-9314,
| |
Collapse
|
14
|
Borgus JR, Wang Y, DiScenza DJ, Venton BJ. Spontaneous Adenosine and Dopamine Cotransmission in the Caudate-Putamen Is Regulated by Adenosine Receptors. ACS Chem Neurosci 2021; 12:4371-4379. [PMID: 34783243 DOI: 10.1021/acschemneuro.1c00175] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Transient changes in adenosine and dopamine have been measured in vivo, but no studies have examined if these transient changes occur simultaneously. In this study, we characterized spontaneous adenosine and dopamine transients in anesthetized mice, examining coincident release in the caudate-putamen for the first time. We found that in C57B mice, most of the dopamine transients (77%) were coincident with adenosine, but fewer adenosine transients (12%) were coincident with a dopamine transient. On average, the dopamine transient started 200 ms before its coincident adenosine transient, so they occurred concurrently. There was a positive correlation (r = 0.7292) of adenosine and dopamine concentrations during coincident release. ATP is quickly broken down to adenosine in the extracellular space, and the coincident events may be due to corelease, where dopaminergic vesicles are packaged with ATP, or cotransmission, where ATP is packaged in different vesicles released simultaneously with dopamine. The high frequency of adenosine transients compared to that of dopamine transients suggests that adenosine is also released from nondopaminergic vesicles. We investigated how A1 and A2A adenosine receptors regulate adenosine and dopamine transients using A1 and A2AKO mice. In A1KO mice, the frequency of adenosine and dopamine transients increased, while in A2AKO mice, the frequency of adenosine alone increased. Adenosine receptors modulate coincident transients and could be drug targets to modulate both dopamine and adenosine release. Many spontaneous dopamine transients have coincident adenosine release, and regulating adenosine and dopamine cotransmission could be important for designing treatments for dopamine diseases, such as Parkinson's or addiction.
Collapse
Affiliation(s)
- Jason R. Borgus
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22901, United States
| | - Ying Wang
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22901, United States
| | - Dana J. DiScenza
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22901, United States
| | - B. Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22901, United States
| |
Collapse
|
15
|
Rafi H, Zestos AG. Multiplexing neurochemical detection with carbon fiber multielectrode arrays using fast-scan cyclic voltammetry. Anal Bioanal Chem 2021; 413:6715-6726. [PMID: 34259877 PMCID: PMC8551007 DOI: 10.1007/s00216-021-03526-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/28/2021] [Accepted: 07/01/2021] [Indexed: 10/20/2022]
Abstract
Carbon fiber microelectrodes (CFMEs) have been extensively used to measure neurotransmitters with fast-scan cyclic voltammetry (FSCV) due to their ability to adsorb cationic monoamine neurotransmitters. Although FSCV, in tandem with CFMEs, provides high temporal and spatial resolution, only single-channel potentiostats and electrodes have been primarily utilized. More recently, the need and use of carbon fiber multielectrode arrays has risen to target multiple brain regions. Previous studies have shown the ability to detect dopamine using multielectrode arrays; however, they are not readily available to the scientific community. In this work, we interfaced a carbon fiber multielectrode array (MEA or multielectrode array), to a commercially available four-channel potentiostat for multiplexing neurochemical measurements. The MEA's relative performance was compared to single CFMEs where dopamine detection was found to be adsorption controlled to the electrode's surface. Multiple waveforms were applied to each fiber of the multielectrode array simultaneously to detect different analytes on each electrode of the array. A proof of concept ex vivo experiment showed that the multielectrode array could record redox activity in different areas within the mouse caudate putamen and detect dopamine in a 3-mm2 area. To our knowledge, this is the first use of the multielectrode array paired with a commercially available multichannel potentiostat for multi-waveform application and neurotransmitter co-detection. This novel array may aid in future studies to better understand complex brain heterogeneity, the dynamic neurochemical environment, and how disease states or drugs affect separate brain areas concurrently. Graphical abstract.
Collapse
Affiliation(s)
- Harmain Rafi
- Center for Neuroscience and Behavior, American University, Washington, DC, 20016, USA
- Department of Neuroscience, American University, Washington, DC, 20016, USA
| | - Alexander G Zestos
- Center for Neuroscience and Behavior, American University, Washington, DC, 20016, USA.
- Department of Chemistry, American University, Washington, DC, 20016, USA.
| |
Collapse
|
16
|
Mena S, Dietsch S, Berger SN, Witt CE, Hashemi P. Novel, User-Friendly Experimental and Analysis Strategies for Fast Voltammetry: 1. The Analysis Kid for FSCV. ACS MEASUREMENT SCIENCE AU 2021; 1:11-19. [PMID: 36785731 PMCID: PMC9836074 DOI: 10.1021/acsmeasuresciau.1c00003] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Fast-scan cyclic voltammetry (FSCV) at carbon fiber microelectrodes measures low concentrations of analytes in biological systems. There are ongoing efforts to simplify FSCV analysis, and several custom platforms are available for filtering and multimodal analysis of FSCV signals, but there is no single, easily accessible platform that has the capacity for all of these features. Here we present The Analysis Kid: currently, the only free, open-source cloud application that does not require a specialized runtime environment and is easily accessible via common browsers. We show that a user-friendly interface can analyze multiplatform file formats to provide multimodal visualization of FSCV color plots with digital background subtraction. We highlight key features that allow interactive calibration and semiautomatic parametric analysis via peak finding algorithms to automatically detect the maximum amplitude, area under the curve, and clearance rate of the signal. Finally, The Analysis Kid enables semiautomatic fitting of data with Michaelis-Menten kinetics with single or dual reuptake models. The Analysis Kid can be freely accessed at http://analysis-kid.hashemilab.com/. The web application code is found, under an MIT license, at https://github.com/sermeor/The-Analysis-Kid.
Collapse
Affiliation(s)
- Sergio Mena
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Solene Dietsch
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| | - Shane N. Berger
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Colby E. Witt
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina 29208, United States
| | - Parastoo Hashemi
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina 29208, United States
- . Phone: +44
20 7594 9193
| |
Collapse
|
17
|
Holmes J, Witt CE, Keen D, Buchanan AM, Batey L, Hersey M, Hashemi P. Glutamate Electropolymerization on Carbon Increases Analytical Sensitivity to Dopamine and Serotonin: An Auspicious In Vivo Phenomenon in Mice? Anal Chem 2021; 93:10762-10771. [PMID: 34328714 DOI: 10.1021/acs.analchem.0c04316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Carbon is the material of choice for electroanalysis of biological systems, being particularly applicable to neurotransmitter analysis as carbon fiber microelectrodes (CFMs). CFMs are most often applied to dopamine detection; however, the scope of CFM analysis has rapidly expanded over the last decade with our laboratory's focus being on improving serotonin detection at CFMs, which we achieved in the past via Nafion modification. We began this present work by seeking to optimize this modification to gain increased analytical sensitivity toward serotonin under the assumption that exposure of bare carbon to the in vivo environment rapidly deteriorates analytical performance. However, we were unable to experimentally verify this assumption and found that electrodes that had been exposed to the in vivo environment were more sensitive to evoked and ambient dopamine. We hypothesized that high in vivo concentrations of ambient extracellular glutamate could polymerize with a negative charge onto CFMs and facilitate response to dopamine. We verified this polymerization electrochemically and characterized the mechanisms of deposition with micro- and nano-imaging. Importantly, we identified that the application of 1.3 V as a positive upper waveform limit is a crucial factor for facilitating glutamate polymerization, thus improving analytical performance. Critically, information gained from these dopamine studies were extended to an in vivo environment where a 2-fold increase in sensitivity to evoked serotonin was achieved. Thus, we present here the novel finding that innate aspects of the in vivo environment are auspicious for detection of dopamine and serotonin at carbon fibers, offering a solution to our goal of an improved fast-scan cyclic voltammetry serotonin detection paradigm.
Collapse
Affiliation(s)
- Jordan Holmes
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States
| | - Colby E Witt
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States
| | - Deanna Keen
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States
| | - Anna Marie Buchanan
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States.,Department of Pharmacology, Physiology, & Neuroscience, University of South Carolina SOM, Columbia, South Carolina, 29209 United States
| | - Lauren Batey
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States.,Department of Bioengineering, Imperial College, London, SW7 2AZ UK
| | - Melinda Hersey
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States.,Department of Pharmacology, Physiology, & Neuroscience, University of South Carolina SOM, Columbia, South Carolina, 29209 United States
| | - Parastoo Hashemi
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, South Carolina, 29208 United States.,Department of Bioengineering, Imperial College, London, SW7 2AZ UK
| |
Collapse
|
18
|
Extended sawhorse waveform for stable zinc detection with fast-scan cyclic voltammetry. Anal Bioanal Chem 2021; 413:6727-6735. [PMID: 34268588 DOI: 10.1007/s00216-021-03529-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 07/01/2021] [Accepted: 07/06/2021] [Indexed: 10/20/2022]
Abstract
Zinc (Zn(II)) is a divalent cation involved in regulating intracellular signal transduction and gene expression through transcription factor activity, and can act as a metal neurotransmitter by modulating synaptic activity and neuronal plasticity. Previous research has demonstrated spatial heterogeneity of Zn(II) in the brain, has estimated extracellular concentrations of Zn(II) across various brain regions, and has measured rapid intracellular changes in Zn(II) concentration during glutamate flux. Despite this work, quantification of rapid extracellular Zn(II) release from neurons, on a millisecond time scale, in real time has remained difficult with existing technologies. Here, we have developed an electrochemical waveform, called the "extended sawhorse waveform (ESW)," for fast-scan cyclic voltammetry detection at carbon-fiber microelectrodes which enabled rapid and stable Zn(II) monitoring over time. This waveform was developed to overcome existing challenges in monitoring metallotransmitters stably over time electrochemically by introducing a brief cleaning step to facilitate rapid cleaning of the electrode surface in between scans. The ESW scans from 0.5 V down to -1.0 V, up to 1.45 V for 3 ms (cleaning step), and back to 0.5 V at a scan rate of 400 V/s. Repeated introductions of Zn(II) at the electrode using a traditional waveform cause plating which ultimately deteriorates the sensitivity over time; however, using the ESW, significant improvements in stability were observed. Overall, we provide a unique approach to monitor and quantitate rapid Zn(II) signaling in the brain at carbon electrodes which will impact our ability to advance fundamental knowledge of Zn(II) involvement in extracellular signaling pathways in the brain.
Collapse
|
19
|
Li Y, Weese ME, Cryan MT, Ross AE. Amine-functionalized carbon-fiber microelectrodes for enhanced ATP detection with fast-scan cyclic voltammetry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2320-2330. [PMID: 33960336 PMCID: PMC8202729 DOI: 10.1039/d1ay00089f] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Here, we provide evidence that functionalizing the carbon-fiber surface with amines significantly improves direct electrochemical adenosine triphosphate (ATP) detection with fast-scan cyclic voltammetry (FSCV). ATP is an important extracellular signaling molecule throughout the body and can function as a neurotransmitter in the brain. Several methods have been developed over the years to monitor and quantitate ATP signaling in cells and tissues; however, many of them are limited in temporal resolution or are not capable of measuring ATP directly. FSCV at carbon-fiber microelectrodes is a widely used technique to measure neurotransmitters in real-time. Many electrode treatments have been developed to study the interaction of cationic compounds like dopamine at the carbon surface yet studies investigating how to improve anionic compounds, like ATP, at the carbon fiber surface are lacking. In this work, carbon-fibers were treated with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) which reacts with carboxylic acid groups on the carbon surface followed by reaction with ethylenediamine (EDA) to produce NH2-functionalized carbon surfaces. Overall, we a 5.2 ± 2.5-fold increase in ATP current with an approximately 9-fold increase in amine functionality, as analyzed by X-ray Photoelectron Spectroscopy, on the carbon surface was observed after modification with EDC-EDA. This provides evidence that amine-rich surfaces improve interactions with ATP on the surface. This study provides a detailed analysis of ATP interaction at carbon surfaces and ultimately a method to improve direct and rapid neurological ATP detection in the future.
Collapse
Affiliation(s)
- Yuxin Li
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Moriah E Weese
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Michael T Cryan
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
20
|
Rafi H, Zestos AG. Review-Recent Advances in FSCV Detection of Neurochemicals via Waveform and Carbon Microelectrode Modification. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2021; 168:057520. [PMID: 34108735 PMCID: PMC8186302 DOI: 10.1149/1945-7111/ac0064] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Fast scan cyclic voltammetry (FSCV) is an analytical technique that was first developed over 30 years ago. Since then, it has been extensively used to detect dopamine using carbon fiber microelectrodes (CFMEs). More recently, electrode modifications and waveform refinement have enabled the detection of a wider variety of neurochemicals including nucleosides such as adenosine and guanosine, neurotransmitter metabolites of dopamine, and neuropeptides such as enkephalin. These alterations have facilitated the selectivity of certain biomolecules over others to enhance the measurement of the analyte of interest while excluding interferants. In this review, we detail these modifications and how specializing CFME sensors allows neuro-analytical researchers to develop tools to understand the neurochemistry of the brain in disease states and provide groundwork for translational work in clinical settings.
Collapse
Affiliation(s)
- Harmain Rafi
- Department of Chemistry, American University, Washington, DC 20016, United States of America
- Center for Neuroscience and Behavior, American University, Washington, DC 20016, United States of America
| | - Alexander G. Zestos
- Department of Chemistry, American University, Washington, DC 20016, United States of America
- Center for Neuroscience and Behavior, American University, Washington, DC 20016, United States of America
| |
Collapse
|
21
|
Asrat T, Cho W, Liu FA, Shapiro SM, Bracht JR, Zestos AG. Direct Detection of DNA and RNA on Carbon Fiber Microelectrodes Using Fast-Scan Cyclic Voltammetry. ACS OMEGA 2021; 6:6571-6581. [PMID: 33748569 PMCID: PMC7970473 DOI: 10.1021/acsomega.0c04845] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Accepted: 02/18/2021] [Indexed: 05/04/2023]
Abstract
DNA and RNA have been measured with many techniques but often with relatively long analysis times. In this study, we utilize fast-scan cyclic voltammetry (FSCV) for the subsecond codetection of adenine, guanine, and cytosine, first as free nucleosides, and then within custom synthesized oligos, plasmid DNA, and RNA from the nematode Caenorhabditis elegans. Previous studies have shown the detection of adenosine and guanosine with FSCV with high spatiotemporal resolution, while we have extended the assay to include cytidine and adenine, guanine, and cytosine in RNA and single- and double-stranded DNA (ssDNA and dSDNA). We find that FSCV testing has a higher sensitivity and yields higher peak oxidative currents when detecting shorter oligonucleotides and ssDNA samples at equivalent nucleobase concentrations. This is consistent with an electrostatic repulsion from negatively charged oxide groups on the surface of the carbon fiber microelectrode (CFME), the negative holding potential, and the negatively charged phosphate backbone. Moreover, as opposed to dsDNA, ssDNA nucleobases are not hydrogen-bonded to one another and thus are free to adsorb onto the surface of the carbon electrode. We also demonstrate that the simultaneous determination of nucleobases is not masked even in biologically complex serum samples. This is the first report demonstrating that FSCV, when used with CFMEs, is able to codetect nucleobases when polymerized into DNA or RNA and could potentially pave the way for future uses in clinical, diagnostic, or research applications.
Collapse
Affiliation(s)
- Thomas
M. Asrat
- Department
of Chemistry, American University, Washington, D.C. 20016, United States
| | - Whirang Cho
- Department
of Chemistry, American University, Washington, D.C. 20016, United States
| | - Favian A. Liu
- Department
of Chemistry, American University, Washington, D.C. 20016, United States
| | - Sarah M. Shapiro
- Department
of Biology, American University, Washington, D.C. 20016, United States
| | - John R. Bracht
- Department
of Biology, American University, Washington, D.C. 20016, United States
| | - Alexander G. Zestos
- Department
of Chemistry, American University, Washington, D.C. 20016, United States
| |
Collapse
|
22
|
Li Y, Ross AE. Plasma-treated carbon-fiber microelectrodes for improved purine detection with fast-scan cyclic voltammetry. Analyst 2020; 145:805-815. [PMID: 31820742 DOI: 10.1039/c9an01636h] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Here, we developed N2 and O2 plasma-treated carbon-fiber microelectrodes (CFME) for improved purine detection with fast-scan cyclic voltammetry (FSCV). Plasma treatment affects the topology and functionality of carbon which impacts the electrode-analyte interaction. CFME's are less sensitive to purines compared to catecholamines. Knowledge of how the electrode surface drives purine-electrode interaction would provide insight into methods to improve purine detection. Here, plasma-treated CFME's with N2 and O2 plasma was used to investigate the extent to which the surface functionality and topology affects purine detection and to improve purine sensing with FSCV. On average, O2 plasma increased the oxidative current for adenosine and ATP by 6.0 ± 1.2-fold and 6.4 ± 1.6-fold, and guanosine and GTP by 2.8 ± 0.47-fold and 5.8 ± 1.4-fold, respectively (n = 9). The O2 plasma increased the surface roughness and oxygen functionality. N2 plasma increased the oxidative current for adenosine and ATP by 1.5 ± 0.15-fold and 1.9 ± 0.23-fold, and guanosine and GTP by 1.4 ± 0.20-fold and 1.5 ± 0.20-fold, respectively (n = 11). N2 plasma increased the nitrogen functionality with minimal increases in roughness. Both plasma treatments impacted purines more than dopamine. Langmuir isotherms revealed that both plasma gases impact the theoretical surface coverage and adsorption strength of purines at the electrode. Overall, we show that purine detection is improved at surfaces with increased surface roughness, and oxygen and amine functionality. Plasma-treated CFMEs could be used in the future to study the analyte-electrode interaction of other neurochemicals.
Collapse
Affiliation(s)
- Yuxin Li
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | | |
Collapse
|
23
|
Kuralay F, Gürsoy T. Direct Electrochemistry and Sensitive Detection of Guanosine on Nanopolymeric Surfaces Bearing Boronic Acid Groups. ChemistrySelect 2020. [DOI: 10.1002/slct.202001812] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Filiz Kuralay
- Department of ChemistryFaculty of ScienceHacettepe University 06800 Ankara Turkey
| | - Taner Gürsoy
- Department of ChemistryFaculty of Arts and SciencesOrdu University 52200 Ordu Turkey
| |
Collapse
|
24
|
Lim GN, Regan SL, Ross AE. Subsecond spontaneous catecholamine release in mesenteric lymph node ex vivo. J Neurochem 2020; 155:417-429. [DOI: 10.1111/jnc.15115] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 05/14/2020] [Accepted: 06/15/2020] [Indexed: 12/25/2022]
Affiliation(s)
- Gary N. Lim
- Department of Chemistry University of Cincinnati Cincinnati OH USA
| | - Samantha L. Regan
- Department of Pediatrics University of CincinnatiCollege of Medicine and Division of NeurologyCincinnati Children’s Research Foundation Cincinnati OH USA
- Neuroscience Graduate Program University of Cincinnati Cincinnati OH USA
| | - Ashley E. Ross
- Department of Chemistry University of Cincinnati Cincinnati OH USA
- Neuroscience Graduate Program University of Cincinnati Cincinnati OH USA
| |
Collapse
|
25
|
Regan SL, Cryan MT, Williams MT, Vorhees CV, Ross AE. Enhanced Transient Striatal Dopamine Release and Reuptake in Lphn3 Knockout Rats. ACS Chem Neurosci 2020; 11:1171-1177. [PMID: 32203648 DOI: 10.1021/acschemneuro.0c00033] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
Latrophilin-3 (LPHN3) is an adhesion G protein coupled receptor involved in regulating neuroplasticity. Variants of LPHN3 are associated with increased risk of attention-deficit hyperactivity disorder. Data from mouse, zebrafish, Drosophila, and rat show that disruption of LPHN3 results in hyperactivity, and in the Sprague-Dawley Lphn3 knockout rat, exhibit deficits in learning and memory and changes in dopamine (DA) markers in the neostriatum. To determine the effects of Lphn3 deletion on DA neurotransmission, we compared the concentration, duration, and frequency of DA transients in KO and wild-type rats using fast-scan cyclic voltammetry in brain slices. Lphn3 KO rats showed higher release of DA, and the duration and interevent time were markedly decreased compared with wild-type rats. The data demonstrate that LPHN3 plays a heretofore unrecognized role in DA signaling and may represent a new target for small molecule regulation of DA neurotransmission with translational implications.
Collapse
Affiliation(s)
- Samantha L. Regan
- Neuroscience Graduate Program, University of Cincinnati, Cincinnati, Ohio 45229, United States
- Department of Pediatrics, University of Cincinnati College of Medicine and Division of Neurology, Cincinnati Children’s Research Foundation, Cincinnati, Ohio 45229, United States
| | - Michael T. Cryan
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45229, United States
| | - Michael T. Williams
- Department of Pediatrics, University of Cincinnati College of Medicine and Division of Neurology, Cincinnati Children’s Research Foundation, Cincinnati, Ohio 45229, United States
| | - Charles V. Vorhees
- Department of Pediatrics, University of Cincinnati College of Medicine and Division of Neurology, Cincinnati Children’s Research Foundation, Cincinnati, Ohio 45229, United States
| | - Ashley E. Ross
- Neuroscience Graduate Program, University of Cincinnati, Cincinnati, Ohio 45229, United States
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45229, United States
| |
Collapse
|
26
|
A microfluidic electrochemical flow cell capable of rapid on-chip dilution for fast-scan cyclic voltammetry electrode calibration. Anal Bioanal Chem 2020; 412:6287-6294. [PMID: 32064570 DOI: 10.1007/s00216-020-02493-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/13/2020] [Accepted: 02/05/2020] [Indexed: 10/25/2022]
Abstract
Here, we developed a microfluidic electrochemical flow cell for fast-scan cyclic voltammetry which is capable of rapid on-chip dilution for efficient and cost-effective electrode calibration. Fast-scan cyclic voltammetry (FSCV) at carbon-fiber microelectrodes is a robust electroanalytical technique used to measure subsecond changes in neurotransmitter concentration over time. Traditional methods of electrode calibration for FSCV require several milliliters of a standard. Additionally, generating calibration curves can be time-consuming because separate solutions must be prepared for each concentration. Microfluidic electrochemical flow cells have been developed in the past; however, they often require incorporating the electrode in the device, making it difficult to remove for testing in biological tissues. Likewise, current microfluidic electrochemical flow cells are not capable of rapid on-chip dilution to eliminate the requirement of making multiple solutions. We designed a T-channel device, with microchannel dimensions of 100 μm × 50 μm, that delivered a standard to a 2-mm-diameter open electrode sampling well. A waste channel with the same dimensions was designed perpendicular to the well to flush and remove the standard. The dimensions of the T-microchannels and flow rates were chosen to facilitate complete mixing in the delivery channel prior to reaching the electrode. The degree of mixing was computationally modeled using COMSOL and was quantitatively assessed in the device using both colored dyes and electrochemical detection. On-chip electrode calibration for dopamine with FSCV was not significantly different than the traditional calibration method demonstrating its utility for FSCV calibration. Overall, this device improves the efficiency and ease of electrode calibration. Graphical abstract.
Collapse
|
27
|
Su Y, Bian S, Sawan M. Real-time in vivo detection techniques for neurotransmitters: a review. Analyst 2020; 145:6193-6210. [DOI: 10.1039/d0an01175d] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Functional synapses in the central nervous system depend on a chemical signal exchange process that involves neurotransmitter delivery between neurons and receptor cells in the neuro system.
Collapse
Affiliation(s)
- Yi Su
- Zhejiang university
- Hangzhou, 310058
- China
- CENBRAIN Lab
- School of Engineering
| | - Sumin Bian
- CENBRAIN Lab
- School of Engineering
- Westlake University
- Hangzhou
- China
| | - Mohamad Sawan
- CENBRAIN Lab
- School of Engineering
- Westlake University
- Hangzhou
- China
| |
Collapse
|
28
|
Ou Y, Buchanan AM, Witt CE, Hashemi P. Frontiers in Electrochemical Sensors for Neurotransmitter Detection: Towards Measuring Neurotransmitters as Chemical Diagnostics for Brain Disorders. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2019; 11:2738-2755. [PMID: 32724337 PMCID: PMC7386554 DOI: 10.1039/c9ay00055k] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
It is extremely challenging to chemically diagnose disorders of the brain. There is hence great interest in designing and optimizing tools for direct detection of chemical biomarkers implicated in neurological disorders to improve diagnosis and treatment. Tools that are capable of monitoring brain chemicals, neurotransmitters in particular, need to be biocompatible, perform with high spatiotemporal resolution, and ensure high selectivity and sensitivity. Recent advances in electrochemical methods are addressing these criteria; the resulting devices demonstrate great promise for in vivo neurotransmitter detection. None of these devices are currently used for diagnostic purposes, however these cutting-edge technologies are promising more sensitive, selective, faster, and less invasive measurements. Via this review we highlight significant technical advances and in vivo studies, performed in the last 5 years, that we believe will facilitate the development of diagnostic tools for brain disorders.
Collapse
Affiliation(s)
- Yangguang Ou
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| | - Anna Marie Buchanan
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| | - Colby E. Witt
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| | - Parastoo Hashemi
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia SC
| |
Collapse
|
29
|
Weese ME, Krevh RA, Li Y, Alvarez NT, Ross AE. Defect Sites Modulate Fouling Resistance on Carbon-Nanotube Fiber Electrodes. ACS Sens 2019; 4:1001-1007. [PMID: 30920207 DOI: 10.1021/acssensors.9b00161] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Carbon nanotube (CNT) fiber electrodes have become increasingly popular electrode materials for neurotransmitter detection with fast-scan cyclic voltammetry (FSCV). The unique properties of CNT fiber electrodes like increased electron transfer, sensitivity, waveform application frequency independence, and resistance to fouling make them ideal biological sensors for FSCV. In particular, their resistance to fouling has been observed for several years, but the specific physical properties which aid in fouling resistance have been debated. Here, we investigate the extent to which the presence of defect sites on the surface attenuate both chemical and biological fouling with FSCV. We compared traditional carbon-fiber microelectrodes (CFMEs) to pristine CNTs and functionalized CNTs. CFMEs and functionalized CNTs are highly disordered with a great deal of defect sites on the surface. The pristine CNTs have fewer defects compared to the purposefully functionalized CNTs and CFMEs. All electrode surfaces were characterized by a combination of scanning electron microscopy (SEM), Raman spectroscopy, and energy dispersive spectroscopy (EDS). Chemical fouling was studied using serotonin, a popular neurotransmitter notoriously known for electrode fouling. To assess biological fouling, electrodes were implanted in brain tissue for 2 h. Defect sites on the carbon were shown to resist biofouling compared to pristine CNTs but were detrimental for serotonin detection. Overall, we provide insight into the extent to which the electrode surface dictates fouling resistance with FSCV. This work provides evidence that careful considerations of the surface of the CNT material are needed when designing sensors for fouling resistance.
Collapse
Affiliation(s)
- Moriah E. Weese
- Department of Chemistry, University of Cincinnati, 404 Crosley Tower, 312 College Dr., Cincinnati, Ohio 45221-0172, United States
| | - Rachel A. Krevh
- Department of Chemistry, University of Cincinnati, 404 Crosley Tower, 312 College Dr., Cincinnati, Ohio 45221-0172, United States
| | - Yuxin Li
- Department of Chemistry, University of Cincinnati, 404 Crosley Tower, 312 College Dr., Cincinnati, Ohio 45221-0172, United States
| | - Noe T. Alvarez
- Department of Chemistry, University of Cincinnati, 404 Crosley Tower, 312 College Dr., Cincinnati, Ohio 45221-0172, United States
| | - Ashley E. Ross
- Department of Chemistry, University of Cincinnati, 404 Crosley Tower, 312 College Dr., Cincinnati, Ohio 45221-0172, United States
| |
Collapse
|
30
|
Cryan MT, Ross AE. Scalene Waveform for Codetection of Guanosine and Adenosine Using Fast-Scan Cyclic Voltammetry. Anal Chem 2019; 91:5987-5993. [DOI: 10.1021/acs.analchem.9b00450] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Michael T. Cryan
- Department of Chemistry, University of Cincinnati, 312 College Drive, 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Ashley E. Ross
- Department of Chemistry, University of Cincinnati, 312 College Drive, 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| |
Collapse
|
31
|
Lim GN, Ross AE. Purine Functional Group Type and Placement Modulate the Interaction with Carbon-Fiber Microelectrodes. ACS Sens 2019; 4:479-487. [PMID: 30657307 DOI: 10.1021/acssensors.8b01504] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Purine detection in the brain with fast-scan cyclic voltammetry (FSCV) at carbon-fiber microelectrodes (CFME) has become increasingly popular over the past decade; despite the growing interest, an in-depth analysis of how purines interact with the CFME at fast-scan rates has not been investigated. Here, we show how the functional group type and placement in the purine ring modulate sensitivity, electron transfer kinetics, and adsorption on the carbon-fiber surface. Similar investigations of catecholamine interaction at CFME with FSCV have informed the development of novel catecholamine-based sensors and is needed for purine-based sensors. We tested purine bases with either amino, carbonyl, or both functional groups substituted at different positions on the ring and an unsubstituted purine. Unsubstituted purine showed very little to no interaction with the electrode surface, indicating that functional groups are important for interaction at the CFME. Purine nucleosides and nucleotides, like adenosine, guanosine, and adenosine triphosphate, are most often probed using FSCV due to their rich extracellular signaling modalities in the brain. Because of this, the extent to which the ribose and triphosphate groups affect the purine-CFME interaction was also evaluated. Amino functional groups facilitated the interaction of purine analogues with CFME more than carbonyl groups, permitting strong adsorption and high surface coverage. Ribose and triphosphate groups decreased the oxidative current and slowed the interaction at the electrode which is likely due to steric effects and electrostatic repulsion. This work provides insight into the factors that affect purine-CFME interaction and conditions to consider when developing purine-targeted sensors for FSCV.
Collapse
Affiliation(s)
- Gary N. Lim
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Ashley E. Ross
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| |
Collapse
|