1
|
Liang Y, Li H, Tang H, Zhang C, Men D, Mayer D. Bioinspired Electrolyte-Gated Organic Synaptic Transistors: From Fundamental Requirements to Applications. NANO-MICRO LETTERS 2025; 17:198. [PMID: 40122950 PMCID: PMC11930914 DOI: 10.1007/s40820-025-01708-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2024] [Accepted: 02/19/2025] [Indexed: 03/25/2025]
Abstract
Rapid development of artificial intelligence requires the implementation of hardware systems with bioinspired parallel information processing and presentation and energy efficiency. Electrolyte-gated organic transistors (EGOTs) offer significant advantages as neuromorphic devices due to their ultra-low operation voltages, minimal hardwired connectivity, and similar operation environment as electrophysiology. Meanwhile, ionic-electronic coupling and the relatively low elastic moduli of organic channel materials make EGOTs suitable for interfacing with biology. This review presents an overview of the device architectures based on organic electrochemical transistors and organic field-effect transistors. Furthermore, we review the requirements of low energy consumption and tunable synaptic plasticity of EGOTs in emulating biological synapses and how they are affected by the organic materials, electrolyte, architecture, and operation mechanism. In addition, we summarize the basic operation principle of biological sensory systems and the recent progress of EGOTs as a building block in artificial systems. Finally, the current challenges and future development of the organic neuromorphic devices are discussed.
Collapse
Affiliation(s)
- Yuanying Liang
- Guangdong Artificial Intelligence and Digital Economy Laboratory (Guangzhou), Guangzhou, 510335, People's Republic of China.
| | - Hangyu Li
- Institute of Biological Information Processing, Bioelectronics IBI-3, Forschungszentrum Jülich, 52425, Jülich, Germany
| | - Hu Tang
- Guangzhou Liby Group Co., Ltd, Guangzhou, 510370, People's Republic of China
| | - Chunyang Zhang
- Guangzhou National Laboratory, Guangzhou, 510005, People's Republic of China
| | - Dong Men
- Guangzhou National Laboratory, Guangzhou, 510005, People's Republic of China
| | - Dirk Mayer
- Institute of Biological Information Processing, Bioelectronics IBI-3, Forschungszentrum Jülich, 52425, Jülich, Germany.
| |
Collapse
|
2
|
Ching T, van Steen ACI, Gray-Scherr D, Teo JL, Vasan A, Jeon J, Shah J, Patel A, Stoddard AE, Bays JL, Eyckmans J, Chen CS. TapeTech microfluidic connectors: adhesive tape-enabled solution for organ-on-a-chip system integration. LAB ON A CHIP 2025; 25:1474-1488. [PMID: 39907088 PMCID: PMC11795533 DOI: 10.1039/d4lc00970c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2024] [Accepted: 01/18/2025] [Indexed: 02/06/2025]
Abstract
A longstanding challenge in microfluidics has been the efficient delivery of fluids from macro-scale pumping systems into microfluidic devices, known as the "world-to-chip" problem. Thus far, the entire industry has accepted the use of imperfect, rigid tubing and connectors as the ecosystem within which to operate, which, while functional, are often cumbersome, labor-intensive, prone to errors, and ill-suited for high-throughput experimentation. In this paper, we introduce TapeTech microfluidics, a flexible and scalable solution designed to address the persistent "world-to-chip" problem in microfluidics, particularly in organ-on-a-chip (OoC) applications. TapeTech offers a streamlined alternative, utilizing adhesive tape and thin-film polymers to create adaptable, integrated multi-channel ribbon connectors that simplify fluidic integration with pumps and reservoirs. Key features of TapeTech include reduced pressure surges, easy priming, rapid setup, easy multiplexing, and broad compatibility with existing devices and components, which are essential for maintaining stable fluid dynamics and protecting sensitive cell cultures. Furthermore, TapeTech is designed to flex around the lids of Petri dishes, enhancing sterility and transportability by enabling easy transfer between incubators, biosafety cabinets (BSCs), and microscopes. The rapid design-to-prototype iteration enabled by TapeTech allows users to quickly develop connectors for a wide range of microfluidic devices. Importantly, we showcase the utility of TapeTech in OoC cultures requiring fluid flow. We also highlight other utilities, such as real-time microscopy and a well-plate medium exchanger. The accessibility of this technology should enable more laboratories to simplify design and setup of microfluidic experiments, and increase technology adoption.
Collapse
Affiliation(s)
- Terry Ching
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Abraham C I van Steen
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Delaney Gray-Scherr
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Jessica L Teo
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Anish Vasan
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Joshua Jeon
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Jessica Shah
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Aayush Patel
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Amy E Stoddard
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
- Harvard-MIT Division of Health Sciences and Technology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jennifer L Bays
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Jeroen Eyckmans
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | - Christopher S Chen
- Biological Design Center, Boston University, Boston, MA 02215, USA.
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| |
Collapse
|
3
|
Ning R, Acree B, Wu M, Gao Y. Microfluidic Monodispersed Microbubble Generation for Production of Cavitation Nuclei. MICROMACHINES 2024; 15:1531. [PMID: 39770284 PMCID: PMC11678649 DOI: 10.3390/mi15121531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2024] [Revised: 12/17/2024] [Accepted: 12/21/2024] [Indexed: 01/11/2025]
Abstract
Microbubbles, acting as cavitation nuclei, undergo cycles of expansion, contraction, and collapse. This collapse generates shockwaves, alters local shear forces, and increases local temperature. Cavitation causes severe changes in pressure and temperature, resulting in surface erosion. Shockwaves strip material from surfaces, forming pits and cracks. Prolonged cavitation reduces the mechanical strength and fatigue life of materials, potentially leading to failure. Controlling bubble size and generating monodispersed bubbles is crucial for accurately modeling cavitation phenomena. In this work, we generate monodispersed microbubbles with controllable size using a novel and low-cost microfluidic method. We created an innovative T-junction structure that controls the two-phase flow for tiny, monodispersed bubble generation. Monodisperse microbubbles with diameters below one-fifth of the channel width (W = 100 µm) are produced due to the controlled pressure gradient. This microstructure, fabricated by a CNC milling technique, produces 20 μm bubbles without requiring high-resolution equipment and cleanroom environments. Bubble size is controlled with gas and liquid pressure ratio and microgeometry. This microbubble generation method provides a controllable and reproducible way for cavitation research.
Collapse
Affiliation(s)
| | | | | | - Yuan Gao
- Department of Mechanical Engineering, The University of Memphis, Memphis, TN 38152, USA; (R.N.); (B.A.); (M.W.)
| |
Collapse
|
4
|
Wu H, Sun H, Oerlemans RAJF, Li S, Shao J, Wang J, Joosten RRM, Lou X, Luo Y, Zheng H, Abdelmohsen LKEA, Garza HHP, van Hest JCM, Friedrich H. Understanding, Mimicking, and Mitigating Radiolytic Damage to Polymers in Liquid Phase Transmission Electron Microscopy. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2402987. [PMID: 39548916 DOI: 10.1002/adma.202402987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 11/07/2024] [Indexed: 11/18/2024]
Abstract
Advances in liquid phase transmission electron microscopy (LP-TEM) have enabled the monitoring of polymer dynamics in solution at the nanoscale, but radiolytic damage during LP-TEM imaging limits its routine use in polymer science. This study focuses on understanding, mimicking, and mitigating radiolytic damage observed in functional polymers in LP-TEM. It is quantitatively demonstrated how polymer damage occurs across all conceivable (LP-)TEM environments, and the key characteristics and differences between polymer degradation in water vapor and liquid water are elucidated. Importantly, it is shown that the hydroxyl radical-rich environment in LP-TEM can be approximated by UV light irradiation in the presence of hydrogen peroxide, allowing the use of bulk techniques to probe damage at the polymer chain level. Finally, the protective effects of commonly used hydroxyl radical scavengers are compared, revealing that the effectiveness of graphene's protection is distance-dependent. The work provides detailed methodological guidance and establishes a baseline for polymer degradation in LP-TEM, paving the way for future research on nanoscale tracking of shape transitions and drug encapsulation of polymer assemblies in solution.
Collapse
Affiliation(s)
- Hanglong Wu
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
- Center for Multiscale Electron Microscopy, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
| | - Hongyu Sun
- DENSsolutions B.V., Informaticalaan 12, Delft, 2628 ZD, The Netherlands
| | - Roy A J F Oerlemans
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | - Siyu Li
- Laboratory of Physical Chemistry, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
| | - Jingxin Shao
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | - Jianhong Wang
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | - Rick R M Joosten
- Center for Multiscale Electron Microscopy, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
- Laboratory of Physical Chemistry, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
| | - Xianwen Lou
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | - Yingtong Luo
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | - Hongkui Zheng
- DENSsolutions B.V., Informaticalaan 12, Delft, 2628 ZD, The Netherlands
| | - Loai K E A Abdelmohsen
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | | | - Jan C M van Hest
- Bio-Organic Chemistry, Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, Eindhoven, 5600 MB, The Netherlands
| | - Heiner Friedrich
- Center for Multiscale Electron Microscopy, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
- Laboratory of Physical Chemistry, Department of Chemical Engineering and Chemistry, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands
| |
Collapse
|
5
|
Ayers AG, Victoriano CM, Sia SK. Integrated device for plasma separation and nucleic acid extraction from whole blood toward point-of-care detection of bloodborne pathogens. LAB ON A CHIP 2024; 24:5124-5136. [PMID: 39421980 PMCID: PMC11487500 DOI: 10.1039/d4lc00571f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Accepted: 10/02/2024] [Indexed: 10/19/2024]
Abstract
Sample preparation presents a major challenge in point-of-care (POC) diagnostic assays, including ones requiring whole blood as the starting specimen. This study presents an integrated sample preparation device - which we call PRECISE - that performs both plasma separation and nucleic acid extraction, enabling streamlined sample preparation from whole blood requiring only a commercially available blood collection tool and a syringe, and no other external equipment or electricity. Plasma separation is performed using a dual-membrane filter (which filters out blood components while limiting membrane clogging) integrated into the cartridge, and nucleic acid extraction is performed by users moving magnets (to mix the samples, and along a guided track). The plasma filtration demonstrated recovery on par with lab-based centrifugation, and the extraction module showed performance similar to benchtop-based magnetic bead extraction. A sample-to-result demonstration on 50 μL of whole blood spiked with virions of hepatitis C virus (HCV), operating the PRECISE cartridge in 16 minutes followed by benchtop PCR, showed a limit of detection (∼6770 IU mL-1) on the order of the minimal requirements of target product profile for POC HCV detection. Future work on the PRECISE cartridge, building on POC accessibility and fast sample preparation demonstrated in this work, may enable detection of bloodborne pathogens from whole-blood specimens collected at the POC.
Collapse
Affiliation(s)
- Abigail G Ayers
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA.
| | | | - Samuel K Sia
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA.
| |
Collapse
|
6
|
Wester M, Lim J, Khaertdinova L, Darsi S, Donthamsetti N, Mensing G, Vasmatzis G, Anastasiadis P, Valera E, Bashir R. On the design and fabrication of nanoliter-volume hanging drop networks. MICROSYSTEMS & NANOENGINEERING 2024; 10:147. [PMID: 39414790 PMCID: PMC11484691 DOI: 10.1038/s41378-024-00788-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 07/29/2024] [Accepted: 08/19/2024] [Indexed: 10/18/2024]
Abstract
Hanging drop cultures provide a favorable environment for the gentle, gel-free formation of highly uniform three-dimensional cell cultures often used in drug screening applications. Initial cell numbers can be limited, as with primary cells provided by minimally invasive biopsies. Therefore, it can be beneficial to divide cells into miniaturized arrays of hanging drops to supply a larger number of samples. Here, we present a framework for the miniaturization of hanging drop networks to nanoliter volumes. The principles of a single hanging drop are described and used to construct the fundamental equations for a microfluidic system composed of multiple connected drops. Constitutive equations for the hanging drop as a nonlinear capacitive element are derived for application in the electronic-hydraulic analogy, forming the basis for more complex, time-dependent numerical modeling of hanging drop networks. This is supplemented by traditional computational fluid dynamics simulation to provide further information about flow conditions within the wells. A fabrication protocol is presented and demonstrated for creating transparent, microscale arrays of pinned hanging drops. A custom interface, pressure-based fluidic system, and environmental chamber have been developed to support the device. Finally, fluid flow on the chip is demonstrated to align with expected behavior based on the principles derived for hanging drop networks. Challenges with the system and potential areas for improvement are discussed. This paper expands on the limited body of hanging drop network literature and provides a framework for designing, fabricating, and operating these systems at the microscale.
Collapse
Affiliation(s)
- Matthew Wester
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - Jongwon Lim
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - Liliana Khaertdinova
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - Sriya Darsi
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - Neel Donthamsetti
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - Glennys Mensing
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
| | - George Vasmatzis
- Center for Individualized Medicine, Mayo Clinic, Rochester, MN, 55905, USA
- Mayo-Illinois Alliance for Technology-Based Healthcare, Urbana, IL, 61801, USA
| | - Panos Anastasiadis
- Mayo-Illinois Alliance for Technology-Based Healthcare, Urbana, IL, 61801, USA
- Department of Cancer Biology, Mayo Clinic, Jacksonville, FL, 32224, USA
| | - Enrique Valera
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- Biomedical Research Center, Carle Foundation Hospital, Urbana, IL, 61801, USA
| | - Rashid Bashir
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA.
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, 61801, USA.
- Mayo-Illinois Alliance for Technology-Based Healthcare, Urbana, IL, 61801, USA.
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Biomedical Research Center, Carle Foundation Hospital, Urbana, IL, 61801, USA.
- Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Department of Biomedical and Translation Science, Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Chan Zuckerberg Biohub Chicago, Chicago, IL, 60642, USA.
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
- Department of Materials Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
| |
Collapse
|
7
|
Baban NS, Zhou J, Elkhoury K, Bhattacharjee S, Vijayavenkataraman S, Gupta N, Song YA, Chakrabarty K, Karri R. BioTrojans: viscoelastic microvalve-based attacks in flow-based microfluidic biochips and their countermeasures. Sci Rep 2024; 14:19806. [PMID: 39191836 PMCID: PMC11350023 DOI: 10.1038/s41598-024-70703-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Accepted: 08/20/2024] [Indexed: 08/29/2024] Open
Abstract
Flow-based microfluidic biochips (FMBs) are widely used in biomedical research and diagnostics. However, their security against potential material-level cyber-physical attacks remains inadequately explored, posing a significant future challenge. One of the main components, polydimethylsiloxane (PDMS) microvalves, is pivotal to FMBs' functionality. However, their fabrication, which involves thermal curing, makes them susceptible to chemical tampering-induced material degradation attacks. Here, we demonstrate one such material-based attack termed "BioTrojans," which are chemically tampered and optically stealthy microvalves that can be ruptured through low-frequency actuations. To chemically tamper with the microvalves, we altered the associated PDMS curing ratio. Attack demonstrations showed that BioTrojan valves with 30:1 and 50:1 curing ratios ruptured quickly under 2 Hz frequency actuations, while authentic microvalves with a 10:1 ratio remained intact even after being actuated at the same frequency for 2 days (345,600 cycles). Dynamic mechanical analyzer (DMA) results and associated finite element analysis revealed that a BioTrojan valve stores three orders of magnitude more mechanical energy than the authentic one, making it highly susceptible to low-frequency-induced ruptures. To counter BioTrojan attacks, we propose a security-by-design approach using smooth peripheral fillets to reduce stress concentration by over 50% and a spectral authentication method using fluorescent microvalves capable of effectively detecting BioTrojans.
Collapse
Affiliation(s)
- Navajit Singh Baban
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates.
| | - Jiarui Zhou
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Kamil Elkhoury
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Sukanta Bhattacharjee
- Department of Computer Science and Engineering, Indian Institute of Technology Guwahati, Guwahati, India
| | | | - Nikhil Gupta
- Department of Mechanical and Aerospace Engineering, New York University, New York, USA
| | - Yong-Ak Song
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates
| | - Krishnendu Chakrabarty
- School of Electrical, Computer and Energy Engineering, Arizona State University, Arizona, USA
| | - Ramesh Karri
- Department of Electrical and Computer Engineering, New York University, New York, USA
| |
Collapse
|
8
|
Shao M, Li C, Meng C, Liu R, Yu P, Lu F, Zhong Z, Wei X, Zhou J, Zhong MC. Laser-induced microbubble as an in vivo valve for optofluidic manipulation in living Mice's microvessels. LAB ON A CHIP 2024; 24:3480-3489. [PMID: 38899528 DOI: 10.1039/d4lc00095a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/21/2024]
Abstract
Optofluidic regulation of blood microflow in vivo represents a significant method for investigating illnesses linked to abnormal changes in blood circulation. Currently, non-invasive strategies are limited to regulation within capillaries of approximately 10 μm in diameter because the adaption to blood pressure levels in the order of several hundred pascals poses a significant challenge in larger microvessels. In this study, using laser-induced microbubble formation within microvessels of the mouse auricle, we regulate blood microflow in small vessels with diameters in the tens of micrometers. By controlling the laser power, we can control the growth and stability of microbubbles in vivo. This controlled approach enables the achievement of prolonged ischemia and subsequent reperfusion of blood flow, and it can also regulate the microbubbles to function as micro-pumps for reverse blood pumping. Furthermore, by controlling the microbubble, narrow microflow channels can be formed between the microbubbles and microvessels for assessing the apparent viscosity of leukocytes, which is 76.9 ± 11.8 Pa·s in the in vivo blood environment. The proposed design of in vivo microbubble valves opens new avenues for constructing real-time blood regulation and exploring cellular mechanics within living organisms.
Collapse
Affiliation(s)
- Meng Shao
- Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China.
| | - Changxu Li
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
| | - Chun Meng
- Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China.
| | - Rui Liu
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
| | - Panpan Yu
- Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China.
| | - Fengya Lu
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
| | - Zhensheng Zhong
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
| | - Xunbin Wei
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
- Biomedical Engineering Department and Cancer Hospital and Institute, Key Laboratory of Carcinogenesis and Translational Research, Peking University, 100081, Beijing, China.
| | - Jinhua Zhou
- School of Biomedical Engineering, Anhui Medical University, Hefei, 230032, China.
| | - Min-Cheng Zhong
- Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, China.
| |
Collapse
|
9
|
Carvalho DJ, Kip AM, Tegel A, Stich M, Krause C, Romitti M, Branca C, Verhoeven B, Costagliola S, Moroni L, Giselbrecht S. A Modular Microfluidic Organoid Platform Using LEGO-Like Bricks. Adv Healthc Mater 2024; 13:e2303444. [PMID: 38247306 PMCID: PMC11481080 DOI: 10.1002/adhm.202303444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 01/12/2024] [Indexed: 01/23/2024]
Abstract
The convergence of organoid and organ-on-a-chip (OoC) technologies is urgently needed to overcome limitations of current 3D in vitro models. However, integrating organoids in standard OoCs faces several technical challenges, as it is typically laborious, lacks flexibility, and often results in even more complex and less-efficient cell culture protocols. Therefore, specifically adapted and more flexible microfluidic platforms need to be developed to facilitate the incorporation of complex 3D in vitro models. Here, a modular, tubeless fluidic circuit board (FCB) coupled with reversibly sealed cell culture bricks for dynamic culture of embryonic stem cell-derived thyroid follicles is developed. The FCB is fabricated by milling channels in a polycarbonate (PC) plate followed by thermal bonding against another PC plate. LEGO-like fluidic interconnectors allow plug-and-play connection between a variety of cell culture bricks and the FCB. Lock-and-play clamps are integrated in the organoid brick to enable easy (un)loading of organoids. A multiplexed perfusion experiment is conducted with six FCBs, where thyroid organoids are transferred on-chip within minutes and cultured up to 10 d without losing their structure and functionality, thus validating this system as a flexible, easy-to-use platform, capable of synergistically combining organoids with advanced microfluidic platforms.
Collapse
Affiliation(s)
- Daniel J. Carvalho
- Department of Instructive Biomaterials EngineeringMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Anna M. Kip
- Department of Complex Tissue RegenerationMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Andreas Tegel
- PreSens Precision Sensing GmbHAm Biopark 1193053RegensburgGermany
| | - Matthias Stich
- PreSens Precision Sensing GmbHAm Biopark 1193053RegensburgGermany
| | - Christian Krause
- PreSens Precision Sensing GmbHAm Biopark 1193053RegensburgGermany
| | - Mírian Romitti
- Institute of Interdisciplinary Research in Molecular Human Biology (IRIBHM)Université Libre de Bruxelles808 route de LennikAnderlecht1070Belgium
| | - Carlotta Branca
- Department of Complex Tissue RegenerationMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Bart Verhoeven
- IDEE Instrument Development Engineering and Evaluation – Research EngineeringUniversiteitssingel 50Maastricht6200 MDThe Netherlands
| | - Sabine Costagliola
- Institute of Interdisciplinary Research in Molecular Human Biology (IRIBHM)Université Libre de Bruxelles808 route de LennikAnderlecht1070Belgium
| | - Lorenzo Moroni
- Department of Complex Tissue RegenerationMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Stefan Giselbrecht
- Department of Instructive Biomaterials EngineeringMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| |
Collapse
|
10
|
Xu F, Ma L, Fan Y. Air trap and removal on a pressure driven PDMS-based microfluidic device. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2024; 95:055003. [PMID: 38739426 DOI: 10.1063/5.0190337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 04/23/2024] [Indexed: 05/14/2024]
Abstract
With the development of microfluidic technology, microfluidic chips have played a positive role in applications such as cell culture, microfluidic PCR, and nanopore gene sequencing. However, the presence of bubbles interferes with fluid flow and has a significant impact on experimental results. There are many reasons for the generation of bubbles in microfluidic chips, such as pressure changes inside the chip, air vibration inside the chip, and the open chip guiding air into the chip when driving fluid. This study designed and prepared a microfluidic device based on polydimethylsiloxane. First, air was actively introduced into the microfluidic chip, and bubbles were captured through the microfluidic device to simulate the presence of bubbles inside the chip in biological experiments. To remove bubbles trapped in the microfluidic chip, distilled water, distilled water containing surfactants, and mineral oil were pumped into the microfluidic chip. We compared and discussed the bubble removal efficiency under different driving fluids, driving pressures, and open/closed channel configurations. This study helps to understand the mechanism of bubble formation and removal in microfluidic devices, optimize chip structure design and experimental reagent selection, prevent or eliminate bubbles, and reduce the impact of bubbles on experiments.
Collapse
Affiliation(s)
- Fan Xu
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Liang Ma
- Department of Clinical Laboratory, China-Japan Friendship Hospital, Beijing 100029, China
| | - Yiqiang Fan
- School of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| |
Collapse
|
11
|
Hoven D, Inaoka M, McCoy R, Withers A, Owens RM, Malliaras GG. Simple dynamic cell culture system reduces recording noise in microelectrode array recordings. MRS COMMUNICATIONS 2024; 14:261-266. [PMID: 38966401 PMCID: PMC11219396 DOI: 10.1557/s43579-024-00554-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Accepted: 04/11/2024] [Indexed: 07/06/2024]
Abstract
Microelectrode arrays (MEAs) have applications in drug discovery, toxicology, and basic research. They measure the electrophysiological response of tissue cultures to quantify changes upon exposure to biochemical stimuli. Unfortunately, manual addition of chemicals introduces significant noise in the recordings. Here, we report a simple-to-fabricate fluidic system that addresses this issue. We show that cell cultures can be successfully established in the fluidic compartment under continuous flow conditions and that the addition of chemicals introduces minimal noise in the recordings. This dynamic cell culture system represents an improvement over traditional tissue culture wells used in MEAs, facilitating electrophysiology measurements. Graphical abstract
Collapse
Affiliation(s)
- Darius Hoven
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA UK
| | - Misaki Inaoka
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA UK
| | - Reece McCoy
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS UK
| | - Aimee Withers
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS UK
| | - Róisín M. Owens
- Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS UK
| | - George G. Malliaras
- Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA UK
| |
Collapse
|
12
|
Dai X, Si W, Liu Y, Zhang W, Guo Z. Bubble Unidirectional Transportation on Multipath Aerophilic Surfaces by Adjusting the Surface Microstructure. ACS APPLIED MATERIALS & INTERFACES 2024; 16:11984-11996. [PMID: 38407018 DOI: 10.1021/acsami.3c15880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/27/2024]
Abstract
Comprehending and controlling the behavior of bubbles on solid surfaces is of significant importance in various fields including catalysis and drag reduction, both industrially and scientifically. Herein, Inspired by the superaerophilic properties of the lotus leaf surface, a series of asymmetrically patterned aerophilic surfaces were prepared by utilizing a facile mask-spraying method for directional transport of underwater bubbles. The ability of bubbles to undergo self-driven transportation in an asymmetric pattern is attributed to the natural tendency of bubbles to move toward regions with lower surface energy. In this work, the microstructure of the aerophilic surface is demonstrated as a critical element that influences the self-driven transport of bubbles toward regions of lower surface energy. The microstructure characteristic affects the energy barrier of forming a continuous gas film on the final regions. We classify three distinct bubble behaviors on the aerophilic surface, which align with three different underwater gas film evolution states: Model I, Model II, and Model III. Furthermore, utilizing the energy difference between the energy barrier that forms a continuous gas film and the gas-gas merging, gas-liquid microreaction in a specific destination on the multiple paths can be easily realized by preinjecting a bubble in the final region. This work provides a new view of the microevolutionary process for the diffusion, transport, and merging behavior of bubbles upon contact with an aerophilic pattern surface.
Collapse
Affiliation(s)
- Xin Dai
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
| | - Wen Si
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
| | - Yifan Liu
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| | - Wenhao Zhang
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
| | - Zhiguang Guo
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| |
Collapse
|
13
|
Nakajima R, Wago H, Taniguchi T, Sasaki Y, Nishiki Y, Awaludin Z, Nakai T, Kato A, Mitsushima S, Kuroda Y. Mesoporous hydrogel electrodes with flexible frameworks exhibiting enhanced mass transport for the oxygen evolution reaction. Chem Commun (Camb) 2024; 60:2536-2539. [PMID: 38329271 DOI: 10.1039/d3cc04632j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2024]
Abstract
Mesoporous hydrogel electrodes with unique flexible mesopores surrounded by CoOOH nanosheets were prepared via the electrochemical deposition of hybrid cobalt hydroxide nanosheets, exhibiting high oxygen evolution reaction activity at a high current density owing to the enhanced mass transport of oxygen molecules.
Collapse
Affiliation(s)
- Ritsuki Nakajima
- Department of Chemistry Applications and Life Science, Graduate School of Engineering Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501, Japan.
| | - Hiroki Wago
- Department of Chemistry Applications and Life Science, Graduate School of Engineering Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501, Japan.
| | - Tatsuya Taniguchi
- Kawasaki Heavy Industries Ltd, 1-1 Kawasaki-cho, Akashi, Hyogo 673-8666, Japan
| | - Yuta Sasaki
- Kawasaki Heavy Industries Ltd, 1-1 Kawasaki-cho, Akashi, Hyogo 673-8666, Japan
| | - Yoshinori Nishiki
- De Nora Permelec Ltd, 2023-15 Endo, Fujisawa, Kanagawa 252-0816, Japan
| | - Zaenal Awaludin
- De Nora Permelec Ltd, 2023-15 Endo, Fujisawa, Kanagawa 252-0816, Japan
| | - Takaaki Nakai
- De Nora Permelec Ltd, 2023-15 Endo, Fujisawa, Kanagawa 252-0816, Japan
| | - Akihiro Kato
- De Nora Permelec Ltd, 2023-15 Endo, Fujisawa, Kanagawa 252-0816, Japan
| | - Shigenori Mitsushima
- Department of Chemistry Applications and Life Science, Graduate School of Engineering Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501, Japan.
- Advanced Chemical Energy Research Center, Institute of Advanced Sciences, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501, Japan
| | - Yoshiyuki Kuroda
- Department of Chemistry Applications and Life Science, Graduate School of Engineering Science, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501, Japan.
- Advanced Chemical Energy Research Center, Institute of Advanced Sciences, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501, Japan
| |
Collapse
|
14
|
Hashemiesfahan M, Gelin P, Maisto A, Gardeniers H, De Malsche W. Enhanced Performance of an Acoustofluidic Device by Integrating Temperature Control. MICROMACHINES 2024; 15:191. [PMID: 38398921 PMCID: PMC10892017 DOI: 10.3390/mi15020191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/19/2024] [Accepted: 01/25/2024] [Indexed: 02/25/2024]
Abstract
Acoustofluidics is an emerging research field wherein either mixing or (bio)-particle separation is conducted. High-power acoustic streaming can produce more intense and rapid flow patterns, leading to faster and more efficient liquid mixing. However, without cooling, the temperature of the piezoelectric element that is used to supply acoustic power to the fluid could rise above 50% of the Curie point of the piezomaterial, thereby accelerating its aging degradation. In addition, the supply of excessive heat to a liquid may lead to irreproducible streaming effects and gas bubble formation. To control these phenomena, in this paper, we present a feedback temperature control system integrated into an acoustofluidic setup using bulk acoustic waves (BAWs) to elevate mass transfer and manipulation of particles. The system performance was tested by measuring mixing efficiency and determining the average velocity magnitude of acoustic streaming. The results show that the integrated temperature control system keeps the temperature at the set point even at high acoustic powers and improves the reproducibility of the acoustofluidic setup performance when the applied voltage is as high as 200 V.
Collapse
Affiliation(s)
- Mehrnaz Hashemiesfahan
- µFlow Group, Department of Chemical Engineering, Vrije Universiteit Brussel, 1050 Brussels, Belgium; (P.G.); (A.M.)
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology, Faculty of Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands;
| | - Pierre Gelin
- µFlow Group, Department of Chemical Engineering, Vrije Universiteit Brussel, 1050 Brussels, Belgium; (P.G.); (A.M.)
| | - Antonio Maisto
- µFlow Group, Department of Chemical Engineering, Vrije Universiteit Brussel, 1050 Brussels, Belgium; (P.G.); (A.M.)
| | - Han Gardeniers
- Mesoscale Chemical Systems Group, MESA+ Institute for Nanotechnology, Faculty of Science and Technology, University of Twente, 7500 AE Enschede, The Netherlands;
| | - Wim De Malsche
- µFlow Group, Department of Chemical Engineering, Vrije Universiteit Brussel, 1050 Brussels, Belgium; (P.G.); (A.M.)
| |
Collapse
|
15
|
Lucchetti M, Werr G, Johansson S, Barbe L, Grandmougin L, Wilmes P, Tenje M. Integration of multiple flexible electrodes for real-time detection of barrier formation with spatial resolution in a gut-on-chip system. MICROSYSTEMS & NANOENGINEERING 2024; 10:18. [PMID: 38268774 PMCID: PMC10805851 DOI: 10.1038/s41378-023-00640-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 10/19/2023] [Accepted: 11/05/2023] [Indexed: 01/26/2024]
Abstract
In healthy individuals, the intestinal epithelium forms a tight barrier to prevent gut bacteria from reaching blood circulation. To study the effect of probiotics, dietary compounds and drugs on gut barrier formation and disruption, human gut epithelial and bacterial cells can be cocultured in an in vitro model called the human microbial crosstalk (HuMiX) gut-on-a-chip system. Here, we present the design, fabrication and integration of thin-film electrodes into the HuMiX platform to measure transepithelial electrical resistance (TEER) as a direct readout on barrier tightness in real-time. As various aspects of the HuMiX platform have already been set in their design, such as multiple compressible layers, uneven surfaces and nontransparent materials, a novel fabrication method was developed whereby thin-film metal electrodes were first deposited on flexible substrates and sequentially integrated with the HuMiX system via a transfer-tape approach. Moreover, to measure localized TEER along the cell culture chamber, we integrated multiple electrodes that were connected to an impedance analyzer via a multiplexer. We further developed a dynamic normalization method because the active measurement area depends on the measured TEER levels. The fabrication process and system setup can be applicable to other barrier-on-chip systems. As a proof-of-concept, we measured the barrier formation of a cancerous Caco-2 cell line in real-time, which was mapped at four spatially separated positions along the HuMiX culture area.
Collapse
Affiliation(s)
- Mara Lucchetti
- Luxembourg Centre for Systems Biomedicine (LCSB), University of Luxembourg, Esch-sur-Alzette, L-4362 Luxembourg
| | - Gabriel Werr
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, 751 21 Uppsala, Sweden
| | - Sofia Johansson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, 751 21 Uppsala, Sweden
| | - Laurent Barbe
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, 751 21 Uppsala, Sweden
| | - Léa Grandmougin
- Luxembourg Centre for Systems Biomedicine (LCSB), University of Luxembourg, Esch-sur-Alzette, L-4362 Luxembourg
| | - Paul Wilmes
- Luxembourg Centre for Systems Biomedicine (LCSB), University of Luxembourg, Esch-sur-Alzette, L-4362 Luxembourg
- Department of Life Sciences and Medicine, Faculty of Science, Technology and Medicine, University of Luxembourg, Esch-sur-Alzette, L-4362 Luxembourg
| | - Maria Tenje
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, 751 21 Uppsala, Sweden
| |
Collapse
|
16
|
Xue Y, Hassan Q, Noroozifar M, Sullan RMA, Kerman K. Microfluidic flow injection analysis system for the electrochemical detection of dopamine using diazonium-grafted copper nanoparticles on multi-walled carbon nanotube-modified surfaces. Talanta 2024; 266:125030. [PMID: 37582331 DOI: 10.1016/j.talanta.2023.125030] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 06/27/2023] [Accepted: 08/02/2023] [Indexed: 08/17/2023]
Abstract
In this proof-of-concept study, a microfluidic flow injection analysis (FIA) system was developed using multi-walled carbon nanotube-modified screen-printed carbon electrodes (CNTSPEs) that were modified with copper nanoparticles (CuNPs) following the electrodeposition of the diazonium salt of 4-aminothiophenol to form 4-thiophenol-conjugated CuNPs (CuNPs-CNTSPE). Transmission electron microscopy (TEM), atomic force microscopy (AFM), and scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS) were used to characterize the size of CuNPs, morphology and elemental analysis of CuNPs-CNTSPE, respectively. Using electrochemical impedance spectroscopy (EIS), the charge-transfer resistance (Rct) of CuNPs-CNTSPE was found to be 20-fold lower than that of CNTSPE. The CuNPs-CNTSPE displayed an oxidation peak for dopamine at -0.08 V which is ∼80 mV lower than the one detected using CNTSPE. The modified electrode was used in microfluidic flow injection analysis and offline systems for sensitive detection of dopamine (DA). The pH, flow rate, loop volume, concentration, and type of surfactant were all optimized for on-chip detection. Under the optimal conditions, using phosphate electrolyte solution (pH 6) containing 0.05% (w/v) Tween 20® as the carrier at a flow rate of 0.6 mL min-1 and a loop volume of 50 μL, the calibration curve was linear from 1.5 to 500 nM with a limit of detection of 0.33 nM. This technique was used for the successful detection of DA in real samples with recovery ranging from 96.5% to 103.8%. The microfluidic FIA system described here has the potential to be used as an electrochemical point-of-care device for rapid DA detection with high sensitivity and reproducibility.
Collapse
Affiliation(s)
- Yilei Xue
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Qusai Hassan
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Meissam Noroozifar
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada
| | - Ruby May A Sullan
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada
| | - Kagan Kerman
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
| |
Collapse
|
17
|
Tokuoka Y, Ishida T. Local Microbubble Removal in Polydimethylsiloxane Microchannel by Balancing Negative and Atmospheric Pressures. MICROMACHINES 2023; 15:37. [PMID: 38258156 PMCID: PMC10819605 DOI: 10.3390/mi15010037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 12/20/2023] [Accepted: 12/21/2023] [Indexed: 01/24/2024]
Abstract
Long-term experiments using organoids and tissues are crucial for drug development. Microfluidic devices have been regularly used in long-term experiments. However, microbubbles often form in these devices, and they may damage and starve cells. A method involving the application of negative pressure has been reported to remove microbubbles from microfluidic devices composed of polydimethylsiloxane; however, negative pressure affects the cells and tissues in microfluidic devices. In this study, a local microbubble removal method was developed using a microfluidic device with 0.5 mm thin polydimethylsiloxane sidewalls. The thin sidewalls counterbalanced the negative and atmospheric pressures, thereby localizing the negative pressure near the negatively pressurized chamber. Microbubbles were removed within 5 mm of the negatively pressurized chamber; however, those in an area 7 mm and more from the chamber were not removed. Using the local removal method, a long-term perfusion test was performed, and no contact was confirmed between the bubbles and the simulated tissue for 72 h.
Collapse
Affiliation(s)
- Yasunori Tokuoka
- Department of Mechanical Engineering, School of Engineering, Institute of Technology, Tokyo 226-8503, Japan
| | - Tadashi Ishida
- Department of Mechanical Engineering, School of Engineering, Institute of Technology, Tokyo 226-8503, Japan
| |
Collapse
|
18
|
Wan L, Li M, Law MK, Mak PI, Martins RP, Jia Y. Sub-5-Minute Ultrafast PCR using Digital Microfluidics. Biosens Bioelectron 2023; 242:115711. [PMID: 37797533 DOI: 10.1016/j.bios.2023.115711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 09/08/2023] [Accepted: 09/25/2023] [Indexed: 10/07/2023]
Abstract
The development of a rapid and reliable polymerase chain reaction (PCR) method for point-of-care (POC) diagnosis is crucial for the timely identification of pathogens. Microfluidics, which involves the manipulation of small volumes of fluidic samples, has been shown to be an ideal approach for POC analysis. Among the various microfluidic platforms available, digital microfluidics (DMF) offers high degree of configurability in manipulating μL/nL-scale liquid and achieving automation. However, the successful implementation of ultrafast PCR on DMF platforms presents challenges due to inherent system instability. In this study, we developed a robust and ultrafast PCR in 3.7-5 min with a detection sensitivity comparable to conventional PCR. Specifically, the implementation of the pincer heating scheme homogenises the temperature within a drop. The utilization of a μm-scale porous hydrophobic membrane suppresses the formation of bubbles under high temperatures. The design of a groove around the high-temperature zone effectively mitigates the temperature interference. The integration of a soluble sensor into the droplets provides an accurate and instant in-drop temperature sensing. We envision that the fast, robust, sensitive, and automatic DMF system will empower the POC testing for infectious diseases.
Collapse
Affiliation(s)
- Liang Wan
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China
| | - Mingzhong Li
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Silergy Semiconductor (Macau) Limited, Macao, China
| | - Man-Kay Law
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Pui-In Mak
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Rui P Martins
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China; On Leave from Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - Yanwei Jia
- The State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macao, China; Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China; MoE Frontiers Science Center for Precision Oncology, University of Macau, Macao, China.
| |
Collapse
|
19
|
Seo S, Kim T. Gas transport mechanisms through gas-permeable membranes in microfluidics: A perspective. BIOMICROFLUIDICS 2023; 17:061301. [PMID: 38025658 PMCID: PMC10656118 DOI: 10.1063/5.0169555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 10/30/2023] [Indexed: 12/01/2023]
Abstract
Gas-permeable membranes (GPMs) and membrane-like micro-/nanostructures offer precise control over the transport of liquids, gases, and small molecules on microchips, which has led to the possibility of diverse applications, such as gas sensors, solution concentrators, and mixture separators. With the escalating demand for GPMs in microfluidics, this Perspective article aims to comprehensively categorize the transport mechanisms of gases through GPMs based on the penetrant type and the transport direction. We also provide a comprehensive review of recent advancements in GPM-integrated microfluidic devices, provide an overview of the fundamental mechanisms underlying gas transport through GPMs, and present future perspectives on the integration of GPMs in microfluidics. Furthermore, we address the current challenges associated with GPMs and GPM-integrated microfluidic devices, taking into consideration the intrinsic material properties and capabilities of GPMs. By tackling these challenges head-on, we believe that our perspectives can catalyze innovative advancements and help meet the evolving demands of microfluidic applications.
Collapse
Affiliation(s)
- Sangjin Seo
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea
| | - Taesung Kim
- Author to whom correspondence should be addressed:. Tel.: +82-52-217-2313. Fax: +82-52-217-2409
| |
Collapse
|
20
|
Zhao P, Zhang C, Gong S. Size Ranges of Effective Nucleation Cavities on Gas-Evolving Surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:16101-16110. [PMID: 37920930 DOI: 10.1021/acs.langmuir.3c02235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2023]
Abstract
Bubble nucleation has a significant influence on mass transfer and energy conversion in electrochemical gas-evolving reactions. In this work, we establish a theoretical model for bubble nucleation from gas cavities on gas-evolving surfaces. Based on analyses of transient gas diffusion within the concentration boundary layer and supersaturation equation for stable bubble nuclei, we determined the size ranges of effective nucleation cavities on gas-evolving surfaces under different levels of supersaturation conditions. In addition, a criterion for the incipience of bubble nucleation on gas-evolving surfaces is proposed. We investigate the effects of the contact angle, cone angle, concentration boundary layer thickness, ambient pressure, and temperature on the size ranges of effective nucleation cavities, respectively. We demonstrate that a larger contact angle or a smaller cone angle can broaden the size range of effective cavities, thereby promoting bubble nucleation from cavities. We also show that increasing the concentration boundary layer thickness causes larger cavities to become effective nucleation sites, which significantly expands the size range of effective cavities. In contrast, increasing the ambient pressure enables smaller cavities to become effective nucleation sites, resulting in an expansion in the size range of effective cavities. Results of this work will contribute to the manipulation of bubble nucleation densities and the optimal design of gas-evolving electrodes in various electrochemical gas-evolving reactions.
Collapse
Affiliation(s)
- Panpan Zhao
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Chaoyang Zhang
- Paris Elite Institute of Technology, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Shuai Gong
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
21
|
Lee SM, Balakrishnan HK, Doeven EH, Yuan D, Guijt RM. Chemical Trends in Sample Preparation for Nucleic Acid Amplification Testing (NAAT): A Review. BIOSENSORS 2023; 13:980. [PMID: 37998155 PMCID: PMC10669371 DOI: 10.3390/bios13110980] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/02/2023] [Accepted: 11/07/2023] [Indexed: 11/25/2023]
Abstract
Nucleic acid amplification testing facilitates the detection of disease through specific genomic sequences and is attractive for point-of-need testing (PONT); in particular, the early detection of microorganisms can alert early response systems to protect the public and ecosystems from widespread outbreaks of biological threats, including infectious diseases. Prior to nucleic acid amplification and detection, extensive sample preparation techniques are required to free nucleic acids and extract them from the sample matrix. Sample preparation is critical to maximize the sensitivity and reliability of testing. As the enzymatic amplification reactions can be sensitive to inhibitors from the sample, as well as from chemicals used for lysis and extraction, avoiding inhibition is a significant challenge, particularly when minimising liquid handling steps is also desirable for the translation of the assay to a portable format for PONT. The reagents used in sample preparation for nucleic acid testing, covering lysis and NA extraction (binding, washing, and elution), are reviewed with a focus on their suitability for use in PONT.
Collapse
Affiliation(s)
- Soo Min Lee
- Centre for Regional and Rural Futures (CeRRF), Deakin University, Locked Bag 20000, Geelong, VIC 3220, Australia
| | - Hari Kalathil Balakrishnan
- Department of Chemical Engineering, Khalifa University, Abu Dhabi P.O. Box 127788, United Arab Emirates;
| | - Egan H. Doeven
- School of Life and Environmental Sciences, Deakin University, Locked Bag 20000, Geelong, VIC 3220, Australia;
| | - Dan Yuan
- School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072, Australia;
| | - Rosanne M. Guijt
- Centre for Regional and Rural Futures (CeRRF), Deakin University, Locked Bag 20000, Geelong, VIC 3220, Australia
| |
Collapse
|
22
|
Juste-Lanas Y, Hervas-Raluy S, García-Aznar JM, González-Loyola A. Fluid flow to mimic organ function in 3D in vitro models. APL Bioeng 2023; 7:031501. [PMID: 37547671 PMCID: PMC10404142 DOI: 10.1063/5.0146000] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 06/20/2023] [Indexed: 08/08/2023] Open
Abstract
Many different strategies can be found in the literature to model organ physiology, tissue functionality, and disease in vitro; however, most of these models lack the physiological fluid dynamics present in vivo. Here, we highlight the importance of fluid flow for tissue homeostasis, specifically in vessels, other lumen structures, and interstitium, to point out the need of perfusion in current 3D in vitro models. Importantly, the advantages and limitations of the different current experimental fluid-flow setups are discussed. Finally, we shed light on current challenges and future focus of fluid flow models applied to the newest bioengineering state-of-the-art platforms, such as organoids and organ-on-a-chip, as the most sophisticated and physiological preclinical platforms.
Collapse
Affiliation(s)
| | - Silvia Hervas-Raluy
- Department of Mechanical Engineering, Engineering Research Institute of Aragón (I3A), University of Zaragoza, Zaragoza, Spain
| | | | | |
Collapse
|
23
|
Cauli E, Polidoro MA, Marzorati S, Bernardi C, Rasponi M, Lleo A. Cancer-on-chip: a 3D model for the study of the tumor microenvironment. J Biol Eng 2023; 17:53. [PMID: 37592292 PMCID: PMC10436436 DOI: 10.1186/s13036-023-00372-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 08/03/2023] [Indexed: 08/19/2023] Open
Abstract
The approval of anticancer therapeutic strategies is still slowed down by the lack of models able to faithfully reproduce in vivo cancer physiology. On one hand, the conventional in vitro models fail to recapitulate the organ and tissue structures, the fluid flows, and the mechanical stimuli characterizing the human body compartments. On the other hand, in vivo animal models cannot reproduce the typical human tumor microenvironment, essential to study cancer behavior and progression. This study reviews the cancer-on-chips as one of the most promising tools to model and investigate the tumor microenvironment and metastasis. We also described how cancer-on-chip devices have been developed and implemented to study the most common primary cancers and their metastatic sites. Pros and cons of this technology are then discussed highlighting the future challenges to close the gap between the pre-clinical and clinical studies and accelerate the approval of new anticancer therapies in humans.
Collapse
Affiliation(s)
- Elisa Cauli
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy.
- Accelera Srl, Nerviano, Milan, Italy.
| | - Michela Anna Polidoro
- Hepatobiliary Immunopathology Laboratory, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Simona Marzorati
- Hepatobiliary Immunopathology Laboratory, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | | | - Marco Rasponi
- Department of Electronics, Information and Bioengineering, Politecnico Di Milano, Milan, Italy
| | - Ana Lleo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
- Division of Internal Medicine and Hepatology, Department of Gastroenterology, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| |
Collapse
|
24
|
Carvalho DJ, Kip AM, Romitti M, Nazzari M, Tegel A, Stich M, Krause C, Caiment F, Costagliola S, Moroni L, Giselbrecht S. Thyroid-on-a-Chip: An Organoid Platform for In Vitro Assessment of Endocrine Disruption. Adv Healthc Mater 2023; 12:e2201555. [PMID: 36546709 PMCID: PMC11468662 DOI: 10.1002/adhm.202201555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 11/18/2022] [Indexed: 12/24/2022]
Abstract
Thyroid is a glandular tissue in the human body in which the function can be severely affected by endocrine disrupting chemicals (EDCs). Current in vitro assays to test endocrine disruption by chemical compounds are largely based on 2D thyroid cell cultures, which often fail to precisely evaluate the safety of these compounds. New and more advanced 3D cell culture systems are urgently needed to better recapitulate the thyroid follicular architecture and functions and help to improve the predictive power of such assays. Herein, the development of a thyroid organoid-on-a-chip (OoC) device using polymeric membranous carriers is described. Mouse embryonic stem cell derived thyroid follicles are incorporated in a microfluidic chip for a 4 day experiment at a flow rate of 12 µL min-1 . A reversible seal provides a leak-tight sealing while enabling quick and easy loading/unloading of thyroid follicles. The OoC model shows a high degree of functionality, where organoids retain expression of key thyroid genes and a typical follicular structure. Finally, transcriptional changes following benzo[k]fluoranthene exposure in the OoC device demonstrate activation of the xenobiotic aryl hydrocarbon receptor pathway. Altogether, this OoC system is a physiologically relevant thyroid model, which will represent a valuable tool to test potential EDCs.
Collapse
Affiliation(s)
- Daniel J. Carvalho
- Department of Instructive Biomaterials EngineeringMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Anna M. Kip
- Department of Complex Tissue RegenerationMERLN Institute for Technology‐InspiredRegenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Mírian Romitti
- Institute of Interdisciplinary Research in Molecular Human Biology (IRIBHM)Université Libre de Bruxelles808 route de LennikBrussels1070Belgium
| | - Marta Nazzari
- Department of ToxicogenomicsGROW School for Oncology and Developmental BiologyMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Andreas Tegel
- PreSens Precision Sensing GmbHAm Biopark 1193053RegensburgGermany
| | - Matthias Stich
- PreSens Precision Sensing GmbHAm Biopark 1193053RegensburgGermany
| | - Christian Krause
- PreSens Precision Sensing GmbHAm Biopark 1193053RegensburgGermany
| | - Florian Caiment
- Department of ToxicogenomicsGROW School for Oncology and Developmental BiologyMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Sabine Costagliola
- Institute of Interdisciplinary Research in Molecular Human Biology (IRIBHM)Université Libre de Bruxelles808 route de LennikBrussels1070Belgium
| | - Lorenzo Moroni
- Department of Complex Tissue RegenerationMERLN Institute for Technology‐InspiredRegenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| | - Stefan Giselbrecht
- Department of Instructive Biomaterials EngineeringMERLN Institute for Technology‐Inspired Regenerative MedicineMaastricht UniversityMaastricht6229 ERThe Netherlands
| |
Collapse
|
25
|
Musgrove HB, Saleheen A, Zatorski JM, Arneja A, Luckey CJ, Pompano RR. A Scalable, Modular Degasser for Passive In-Line Removal of Bubbles from Biomicrofluidic Devices. MICROMACHINES 2023; 14:435. [PMID: 36838135 PMCID: PMC9964747 DOI: 10.3390/mi14020435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/01/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Bubbles are a common cause of microfluidic malfunction, as they can perturb the fluid flow within the micro-sized features of a device. Since gas bubbles form easily within warm cell culture reagents, degassing is often necessary for biomicrofluidic systems. However, fabrication of a microscale degasser that can be used modularly with pre-existing chips may be cumbersome or challenging, especially for labs not equipped for traditional microfabrication, and current commercial options can be expensive. Here, we address the need for an affordable, accessible bubble trap that can be used in-line for continuous perfusion of organs-on-chip and other microfluidic cultures. We converted a previously described, manually fabricated PDMS degasser to allow scaled up, reproducible manufacturing by commercial machining or fused deposition modeling (FDM) 3D printing. After optimization, the machined and 3D printed degassers were found to be stable for >2 weeks under constant perfusion, without leaks. With a ~140 µL chamber volume, trapping capacity was extrapolated to allow for ~5-20 weeks of degassing depending on the rate of bubble formation. The degassers were biocompatible for use with cell culture, and they successfully prevented bubbles from reaching a downstream microfluidic device. Both degasser materials showed little to no leaching. The machined degasser did not absorb reagents, while the FDM printed degasser absorbed a small amount, and both maintained fluidic integrity from 1 µL/min to >1 mL/min of pressure-driven flow. Thus, these degassers can be fabricated in bulk and allow for long-term, efficient bubble removal in a simple microfluidic perfusion set-up.
Collapse
Affiliation(s)
- Hannah B. Musgrove
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | - Amirus Saleheen
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| | | | - Abhinav Arneja
- Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA 22904, USA
| | - Chance John Luckey
- Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA 22904, USA
| | - Rebecca R. Pompano
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, USA
| |
Collapse
|
26
|
Ortiz-Cárdenas JE, Zatorski JM, Arneja A, Montalbine AN, Munson JM, Luckey CJ, Pompano RR. Towards spatially-organized organs-on-chip: Photopatterning cell-laden thiol-ene and methacryloyl hydrogels in a microfluidic device. ORGANS-ON-A-CHIP 2022; 4:100018. [PMID: 35535262 PMCID: PMC9078144 DOI: 10.1016/j.ooc.2022.100018] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Micropatterning techniques for 3D cell cultures enable the recreation of tissue-level structures, but the combination of patterned hydrogels with organs-on-chip to generate organized 3D cultures under microfluidic perfusion remains challenging. To address this technological gap, we developed a user-friendly in-situ micropatterning protocol that integrates photolithography of crosslinkable, cell-laden hydrogels with a simple microfluidic housing, and tested the impact of crosslinking chemistry on stability and spatial resolution. Working with gelatin functionalized with photo-crosslinkable moieties, we found that inclusion of cells at high densities (≥ 107/mL) did not impede thiol-norbornene gelation, but decreased the storage moduli of methacryloyl hydrogels. Hydrogel composition and light dose were selected to match the storage moduli of soft tissues. To generate the desired pattern on-chip, the cell-laden precursor solution was flowed into a microfluidic chamber and exposed to 405 nm light through a photomask. The on-chip 3D cultures were self-standing and the designs were interchangeable by simply swapping out the photomask. Thiol-ene hydrogels yielded highly accurate feature sizes from 100 - 900 μm in diameter, whereas methacryloyl hydrogels yielded slightly enlarged features. Furthermore, only thiol-ene hydrogels were mechanically stable under perfusion overnight. Repeated patterning readily generated multi-region cultures, either separately or adjacent, including non-linear boundaries that are challenging to obtain on-chip. As a proof-of-principle, primary human T cells were patterned on-chip with high regional specificity. Viability remained high (> 85%) after 12-hr culture with constant perfusion. We envision that this technology will enable researchers to pattern 3D co-cultures to mimic organ-like structures that were previously difficult to obtain.
Collapse
Affiliation(s)
| | - Jonathan M. Zatorski
- Department of Chemistry, University of Virginia, PO BOX 400319, Charlottesville, VA, USA 22904
| | - Abhinav Arneja
- Department of Pathology, University of Virginia, Charlottesville, VA, USA 22904
| | - Alyssa N. Montalbine
- Department of Chemistry, University of Virginia, PO BOX 400319, Charlottesville, VA, USA 22904
| | - Jennifer M. Munson
- Department of Biomedical Engineering and Mechanics, Fralin Biomedical Research Institute at Virginia Tech-Carilion, Virginia Polytechnic Institute and State University, Roanoke, VA, USA
| | - Chance John Luckey
- Department of Pathology, University of Virginia, Charlottesville, VA, USA 22904
| | - Rebecca R. Pompano
- Department of Chemistry, University of Virginia, PO BOX 400319, Charlottesville, VA, USA 22904
- Department of Chemistry, Carter Immunology Center, University of Virginia, PO BOX 400319, Charlottesville, VA, USA 22904
| |
Collapse
|
27
|
Guo L, Shan J, Ran P, Yin S, Liu C, Li J. Permeation-Enhanced Degassing Method Based on Xylem Embolism Repair and Gas Permeable Materials. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2022; 38:12373-12381. [PMID: 36171077 DOI: 10.1021/acs.langmuir.2c02145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Microfluidic devices have developed a wide range of applications in the fields of biomedicine, chemistry, and analytical science. But it is easy to form and accumulate bubbles in microfluidic devices. These bubbles could decrease the detection sensitivity, cause inaccurate analysis results, and even damage the functional region of the device. Inspired by the embolism repair mechanism of angiosperms and the permeability of gas permeable materials, this work proposes a bioinspired permeation-enhanced degassing method. Bionic redundant pits are used in this method to keep bubbles from spreading between microchannels and maintain the continuity of the flow. A hydrophobic gas permeable material is used to enhance the bubble capture capability and accelerate the degassing process. This method can eliminate bubbles automatically and continuously in real time without auxiliary equipment. Compared to the bubble removal only depending on solution in water, the degassing effect of the permeation-enhanced degassing method shows about 1.6 times improvement in the same conditions, and the capability of trapping bubbles is improved by 1.33 times. In this paper, this method was integrated into a concentration gradient generator and a cell culture device. The results show that the concentration gradient generator with degassing structures can dissolve bubbles in a rapid way and reach the stability of the concentration gradient within 5-15 min. The degassing method can run for a long time and improve the cell density and cell viability of HeLa cells up to 2.64 and 1.12 times, respectively. The method has a broad application prospect in microfluidic fields including biomedical fluid processing, virus detection, and microscale reactor operation.
Collapse
Affiliation(s)
- Lihua Guo
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China
| | - Jie Shan
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China
| | - Penghui Ran
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China
| | - Shuqing Yin
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China
| | - Chong Liu
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China
- Key Laboratory for Precision and Non-traditional Machining Technology of Ministry of Education, Dalian University of Technology, Dalian 116024, China
| | - Jingmin Li
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian 116024, China
| |
Collapse
|
28
|
Puumala LS, Grist SM, Wickremasinghe K, Al-Qadasi MA, Chowdhury SJ, Liu Y, Mitchell M, Chrostowski L, Shekhar S, Cheung KC. An Optimization Framework for Silicon Photonic Evanescent-Field Biosensors Using Sub-Wavelength Gratings. BIOSENSORS 2022; 12:840. [PMID: 36290977 PMCID: PMC9599562 DOI: 10.3390/bios12100840] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 09/30/2022] [Accepted: 09/30/2022] [Indexed: 05/31/2023]
Abstract
Silicon photonic (SiP) evanescent-field biosensors aim to combine the information-rich readouts offered by lab-scale diagnostics, at a significantly lower cost, and with the portability and rapid time to result offered by paper-based assays. While SiP biosensors fabricated with conventional strip waveguides can offer good sensitivity for label-free detection in some applications, there is still opportunity for improvement. Efforts have been made to design higher-sensitivity SiP sensors with alternative waveguide geometries, including sub-wavelength gratings (SWGs). However, SWG-based devices are fragile and prone to damage, limiting their suitability for scalable and portable sensing. Here, we investigate SiP microring resonator sensors designed with SWG waveguides that contain a "fishbone" and highlight the improved robustness offered by this design. We present a framework for optimizing fishbone-style SWG waveguide geometries based on numerical simulations, then experimentally measure the performance of ring resonator sensors fabricated with the optimized waveguides, targeting operation in the O-band and C-band. For the O-band and C-band devices, we report bulk sensitivities up to 349 nm/RIU and 438 nm/RIU, respectively, and intrinsic limits of detection as low as 5.1 × 10-4 RIU and 7.1 × 10-4 RIU, respectively. This performance is comparable to the state of the art in SWG-based sensors, positioning fishbone SWG resonators as an attractive, more robust, alternative to conventional SWG designs.
Collapse
Affiliation(s)
- Lauren S. Puumala
- School of Biomedical Engineering, University of British Columbia, 251-2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Centre for Blood Research, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
| | - Samantha M. Grist
- School of Biomedical Engineering, University of British Columbia, 251-2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Centre for Blood Research, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
| | - Kithmin Wickremasinghe
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| | - Mohammed A. Al-Qadasi
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| | - Sheri Jahan Chowdhury
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| | - Yifei Liu
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| | - Matthew Mitchell
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
- Stewart Blusson Quantum Matter Institute, University of British Columbia, 2355 East Mall, Vancouver, BC V6T 1Z4, Canada
| | - Lukas Chrostowski
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
- Stewart Blusson Quantum Matter Institute, University of British Columbia, 2355 East Mall, Vancouver, BC V6T 1Z4, Canada
| | - Sudip Shekhar
- Dream Photonics Inc., Vancouver, BC V6T 0A7, Canada
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| | - Karen C. Cheung
- School of Biomedical Engineering, University of British Columbia, 251-2222 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Centre for Blood Research, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
- Department of Electrical and Computer Engineering, University of British Columbia, 5500-2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
| |
Collapse
|
29
|
Dai X, Guo Z, Liu W. Ultraviolet-Driven Janus Foams with Wetting Gradients: Unidirectional Penetration Control for Underwater Bubbles. ACS APPLIED MATERIALS & INTERFACES 2022; 14:42734-42743. [PMID: 36070967 DOI: 10.1021/acsami.2c12766] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Understanding the behavior of underwater bubbles and enabling their effective manipulation is important for bubble capture, collection, and transport. Here, to discuss the underwater permeation behavior of bubbles and critical influencing parameters in this process, the copper foams with tunable wettability were fabricated by utilizing the light-stimulated wettability response of TiO2. The Janus copper foams had different wettability gradients from superhydrophobic/hydrophobic to superhydrophobic/hydrophilic after UV irradiation at different times, and the bubbles on the surfaces showed distinctly diverse penetration behaviors. In particular, the constructed superhydrophobic/hydrophilic surfaces showed more difficult to achieve bubble penetration than the fully superhydrophobic, superhydrophobic/hydrophobic surface. It was found that the wetting states of the foams exposed to different irradiation times underwater plays a crucial role in the bubble penetration behavior. In other words, the difficulty of bubble penetration depends on the difficulty of bubble transition from gas-liquid contact to gas-solid contact. This facile and low-cost fabrication approach for Janus foams provided a valuable approach to understand the penetration behaviors of underwater bubbles, which is significant for expanding potential applications in bubble capture, bubble transport, and control of unstable gas reactions in underwater conditions.
Collapse
Affiliation(s)
- Xin Dai
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
| | - Zhiguang Guo
- Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan 430062, People's Republic of China
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| | - Weimin Liu
- State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000, People's Republic of China
| |
Collapse
|
30
|
Gennari G, Jefferson-Loveday R, Pickering SJ. A phase-change model for diffusion-driven mass transfer problems in incompressible two-phase flows. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.117791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
31
|
A novel method for inward fluid displacement in centrifugal microdevices for highly integrated nucleic acid processing with long-term reagent storage. Anal Chim Acta 2022; 1221:340063. [DOI: 10.1016/j.aca.2022.340063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/20/2022] [Accepted: 06/06/2022] [Indexed: 11/18/2022]
|
32
|
Zhou Y, Dai L, Jiao N. Review of Bubble Applications in Microrobotics: Propulsion, Manipulation, and Assembly. MICROMACHINES 2022; 13:1068. [PMID: 35888885 PMCID: PMC9324494 DOI: 10.3390/mi13071068] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 06/30/2022] [Accepted: 07/01/2022] [Indexed: 02/01/2023]
Abstract
In recent years, microbubbles have been widely used in the field of microrobots due to their unique properties. Microbubbles can be easily produced and used as power sources or tools of microrobots, and the bubbles can even serve as microrobots themselves. As a power source, bubbles can propel microrobots to swim in liquid under low-Reynolds-number conditions. As a manipulation tool, microbubbles can act as the micromanipulators of microrobots, allowing them to operate upon particles, cells, and organisms. As a microrobot, microbubbles can operate and assemble complex microparts in two- or three-dimensional spaces. This review provides a comprehensive overview of bubble applications in microrobotics including propulsion, micromanipulation, and microassembly. First, we introduce the diverse bubble generation and control methods. Then, we review and discuss how bubbles can play a role in microrobotics via three functions: propulsion, manipulation, and assembly. Finally, by highlighting the advantages and current challenges of this progress, we discuss the prospects of microbubbles in microrobotics.
Collapse
Affiliation(s)
- Yuting Zhou
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China;
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Liguo Dai
- College of Mechanical and Electrical Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, China;
| | - Niandong Jiao
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China;
- Institutes for Robotics and Intelligent Manufacturing, Chinese Academy of Sciences, Shenyang 110016, China
| |
Collapse
|
33
|
CFD Analysis and Life Cycle Assessment of Continuous Synthesis of Magnetite Nanoparticles Using 2D and 3D Micromixers. MICROMACHINES 2022; 13:mi13060970. [PMID: 35744584 PMCID: PMC9230433 DOI: 10.3390/mi13060970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/26/2022] [Accepted: 05/28/2022] [Indexed: 02/04/2023]
Abstract
Magnetite nanoparticles (MNPs) have attracted basic and applied research due to their immense potential to enable applications in fields as varied as drug delivery and bioremediation. Conventional synthesis schemes led to wide particle size distributions and inhomogeneous morphologies and crystalline structures. This has been attributed to the inability to control nucleation and growth processes under the conventional conditions of bulk batch processes. Here, we attempted to address these issues by scaling down the synthesis process aided by microfluidic devices, as they provide highly controlled and stable mixing patterns. Accordingly, we proposed three micromixers with different channel configurations, namely, serpentine, triangular, and a 3D arrangement with abrupt changes in fluid direction. The micromixers were first studied in silico, aided by Comsol Multiphysics® to investigate the obtained mixing patterns, and consequently, their potential for controlled growth and the nucleation processes required to form MNPs of uniform size and crystalline structure. The devices were then manufactured using a low-cost approach based on polymethyl methacrylate (PMMA) and laser cutting. Testing the micromixers in the synthesis of MNPs revealed homogeneous morphologies and particle size distributions, and the typical crystalline structure reported previously. A life cycle assessment (LCA) analysis for the devices was conducted in comparison with conventional batch co-precipitation synthesis to investigate the potential impacts on water and energy consumption. The obtained results revealed that such consumptions are higher than those of the conventional process. However, they can be reduced by conducting the synthesis with reused micromixers, as new PMMA is not needed for their assembly prior to operation. We are certain that the proposed approach represents an advantageous alternative to co-precipitation synthesis schemes, in terms of continuous production and more homogeneous physicochemical parameters of interest such as size, morphologies, and crystalline structure. Future work should be directed towards improving the sustainability indicators of the micromixers’ manufacturing process.
Collapse
|
34
|
Optimisation of parameters of complete nickel electrodeposition from acidic aqueous electrolytic baths prepared by dissolution of metal powder. J Solid State Electrochem 2022. [DOI: 10.1007/s10008-022-05194-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
35
|
Zhao X, Ma C, Park DS, Soper SA, Murphy MC. Air bubble removal: Wettability contrast enabled microfluidic interconnects. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 361:131687. [PMID: 35611132 PMCID: PMC9124586 DOI: 10.1016/j.snb.2022.131687] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The presence of air bubbles boosts the shear resistance and causes pressure fluctuation within fluid-perfused microchannels, resulting in possible cell damage and even malfunction of microfluidic devices. Eliminating air bubbles is especially challenging in microscale where the adhesive surface tension force is often dominant over other forces. Here, we present an air bubble removal strategy from a novel surface engineering perspective. A microfluidic port-to-port interconnect was fabricated by modifying the peripheral of the microfluidic ports superhydrophobic, while maintaining the inner polymer microchannels hydrophilic. Such a sharp wettability contrast enabled a preferential fluidic entrance into the easy-wetting microchannels over the non-wetting boundaries of the microfluidic ports, while simultaneously filtering out any incoming air bubbles owing to the existence of port-to-port gaps. This bubble-eliminating capability was consistently demonstrated at varying flow rates and liquid analytes. Compared to equipment-intensive techniques and porous membrane-venting strategies, our wettability contrast-governed strategy provides a simple yet effective route for eliminating air bubbles and simultaneously sealing microfluidic interconnects.
Collapse
Affiliation(s)
- Xiaoxiao Zhao
- College of Mechanical and Electrical Engineering, Nanjing Forestry University, Nanjing 210037, Jiangsu, PR China
- Center for BioModular Multiscale Systems for Precision Medicine, Department of Mechanical & Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, United States
| | - Chenbo Ma
- College of Mechanical and Electrical Engineering, Nanjing Forestry University, Nanjing 210037, Jiangsu, PR China
| | - Daniel S. Park
- Center for BioModular Multiscale Systems for Precision Medicine, Department of Mechanical & Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, United States
| | - Steven A. Soper
- Departments of Chemistry and Mechanical Engineering, University of Kansas, Lawrence, KS 66045, United States
| | - Michael C. Murphy
- Center for BioModular Multiscale Systems for Precision Medicine, Department of Mechanical & Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, United States
| |
Collapse
|
36
|
Seyedmirzaei Sarraf S, Rokhsar Talabazar F, Namli I, Maleki M, Sheibani Aghdam A, Gharib G, Grishenkov D, Ghorbani M, Koşar A. Fundamentals, biomedical applications and future potential of micro-scale cavitation-a review. LAB ON A CHIP 2022; 22:2237-2258. [PMID: 35531747 DOI: 10.1039/d2lc00169a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Thanks to the developments in the area of microfluidics, the cavitation-on-a-chip concept enabled researchers to control and closely monitor the cavitation phenomenon in micro-scale. In contrast to conventional scale, where cavitation bubbles are hard to be steered and manipulated, lab-on-a-chip devices provide suitable platforms to conduct smart experiments and design reliable devices to carefully harness the collapse energy of cavitation bubbles in different bio-related and industrial applications. However, bubble behavior deviates to some extent when confined to micro-scale geometries in comparison to macro-scale. Therefore, fundamentals of micro-scale cavitation deserve in-depth investigations. In this review, first we discussed the physics and fundamentals of cavitation induced by tension-based as well as energy deposition-based methods within microfluidic devices and discussed the similarities and differences in micro and macro-scale cavitation. We then covered and discussed recent developments in bio-related applications of micro-scale cavitation chips. Lastly, current challenges and future research directions towards the implementation of micro-scale cavitation phenomenon to emerging applications are presented.
Collapse
Affiliation(s)
- Seyedali Seyedmirzaei Sarraf
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Farzad Rokhsar Talabazar
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Ilayda Namli
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Mohammadamin Maleki
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Araz Sheibani Aghdam
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
| | - Ghazaleh Gharib
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Dmitry Grishenkov
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, SE-141 57 Stockholm, Sweden
| | - Morteza Ghorbani
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| | - Ali Koşar
- Faculty of Engineering and Natural Science, Sabanci University, 34956 Tuzla, Istanbul, Turkey.
- Sabanci University Nanotechnology Research and Application Center, 34956 Tuzla, Istanbul, Turkey
- Center of Excellence for Functional Surfaces and Interfaces for Nano-Diagnostics (EFSUN), Sabanci University, Orhanli, 34956, Tuzla, Istanbul, Turkey
| |
Collapse
|
37
|
Guo L, Liu Y, Ran P, Wang G, Shan J, Li X, Liu C, Li J. A bioinspired bubble removal method in microchannels based on angiosperm xylem embolism repair. MICROSYSTEMS & NANOENGINEERING 2022; 8:34. [PMID: 35402001 PMCID: PMC8940964 DOI: 10.1038/s41378-022-00367-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 01/23/2022] [Accepted: 02/07/2022] [Indexed: 06/14/2023]
Abstract
It is difficult to remove and eliminate bubbles in microchannels in many devices used in various biomedical fields, such as those needed for microfluidic immunoassays, point-of-care testing, and cell biology evaluations. Accumulated bubbles are associated with a number of negative outcomes, including a decrease in device sensitivity, inaccuracy of analysis results, and even functional failure. Xylem conduits of angiosperm have the ability to remove bubbles in obstructed conduits. Inspired by such an embolism repair mechanism, this paper proposes a bioinspired bubble removal method, which exhibits a prominent ability to dissolve bubbles continuously within a large range of flow rates (2 µL/min-850 µL/min) while retaining the stability and continuity of the flow without auxiliary equipment. Such a method also shows significant bubble removal stability in dealing with Newtonian liquids and non-Newtonian fluids, especially with high viscosity (6.76 Pa s) and low velocity (152 nL/min). Such advantages associated with the proposed bioinspired method reveal promising application prospects in macro/microfluidic fields ranging from 3D printing, implantable devices, virus detection, and biomedical fluid processing to microscale reactor operation and beyond.
Collapse
Affiliation(s)
- Lihua Guo
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| | - Yuanchang Liu
- Department of Mechanical Engineering, University College London, Torrington Place, London, WC1E 7JE UK
| | - Penghui Ran
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| | - Gang Wang
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| | - Jie Shan
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| | - Xudong Li
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| | - Chong Liu
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| | - Jingmin Li
- Key Laboratory for Micro/Nano Technology and System of Liaoning Province, Dalian University of Technology, Dalian, China
| |
Collapse
|
38
|
Li M, Wan L, Law MK, Meng L, Jia Y, Mak PI, Martins RP. One-shot high-resolution melting curve analysis for KRAS point-mutation discrimination on a digital microfluidics platform. LAB ON A CHIP 2022; 22:537-549. [PMID: 34904611 DOI: 10.1039/d1lc00564b] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Single-nucleotide polymorphism (SNP) plays a critical role in personalized medicine, forensics, pharmacogenetics, and disease diagnostics. Among different existing SNP genotyping techniques, melting curve analysis (MCA) becomes increasingly popular due to its high accuracy and straightforward procedures in extracting the melting temperature (Tm). Yet, its study on existing digital microfluidic (DMF) platforms has intrinsic limitations due to the temperature inhomogeneity within a thickened droplet during the on-chip rapid heating process. Although the utilization of an on-chip thermostat can regulate and monitor the dynamic melting process in real time, the limited Tm accuracy resulting from the insufficient system response time to accommodate the fast-melting evolution still poses a great challenge for precise MCA with high throughput. This work proposes a one-shot MCA on a DMF platform. The tailoring of a functional substrate with hierarchical micro/nano structure enables high-resolution patterning of pL-scale droplets. Specifically, the hydrothermal and photocatalysis treatment allows the functional substrate to exhibit a superwettability contrast of >170°, facilitating passive isolation of the pL-scale DNA sample into highly-resolved pL droplets above the 200 μm superhydrophilic patterns. This high-resolution MCA technique can successfully discriminate KRAS gene targets with single-nucleotide mutations in 3 seconds. The high accuracy and consistency in the acquired Tm when compared with off-chip results demonstrate its opportunities for near-patient diagnostics, precision medicines, genetic counseling, and prevention strategies on DMF platforms.
Collapse
Affiliation(s)
- Mingzhong Li
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
| | - Liang Wan
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Man-Kay Law
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Li Meng
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Yanwei Jia
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Pui-In Mak
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
| | - Rui P Martins
- State Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Taipa, Macao, China.
- Faculty of Science and Technology - Electrical and Computer Engineering, University of Macau, Macao, China
- On leave from Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
39
|
Xu M, Lee PVS, Collins DJ. Microfluidic acoustic sawtooth metasurfaces for patterning and separation using traveling surface acoustic waves. LAB ON A CHIP 2021; 22:90-99. [PMID: 34860222 DOI: 10.1039/d1lc00711d] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We demonstrate a sawtooth-based metasurface approach for flexibly orienting acoustic fields in a microfluidic device driven by surface acoustic waves (SAW), where sub-wavelength channel features can be used to arbitrarily steer acoustic fringes in a microchannel. Compared to other acoustofluidic methods, only a single travelling wave is used, the fluidic pressure field is decoupled from the fluid domain's shape, and steerable pressure fields are a function of a simply constructed polydimethylsiloxane (PDMS) metasurface shape. Our results are relevant to microfluidic applications including the patterning, concentration, focusing, and separation of microparticles and cells.
Collapse
Affiliation(s)
- Mingxin Xu
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Peter V S Lee
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - David J Collins
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| |
Collapse
|
40
|
Yang Q, Nagar B, Alvarez-Diduk R, Balsells M, Farinelli A, Bloisi D, Proia L, Espinosa C, Ordeix M, Knutz T, De Vito-Francesco E, Allabashi R, Merkoçi A. Development of a Heavy Metal Sensing Boat for Automatic Analysis in Natural Waters Utilizing Anodic Stripping Voltammetry. ACS ES&T WATER 2021; 1:2470-2476. [PMID: 34918010 PMCID: PMC8669633 DOI: 10.1021/acsestwater.1c00192] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 09/29/2021] [Accepted: 09/30/2021] [Indexed: 05/23/2023]
Abstract
Determination of the levels of heavy metal ions would support assessment of sources and pathways of water pollution. However, traditional spatial assessment by manual sampling and off-site detection in the laboratory is expensive and time-consuming and requires trained personnel. Aiming to fill the gap between on-site automatic approaches and laboratory techniques, we developed an autonomous sensing boat for on-site heavy metal detection using square-wave anodic stripping voltammetry. A fluidic sensing system was developed to integrate into the boat as the critical sensing component and could detect ≤1 μg/L Pb, ≤6 μg/L Cu, and ≤71 μg/L Cd simultaneously in the laboratory. Once its integration was completed, the autonomous sensing boat was tested in the field, demonstrating its ability to distinguish the highest concentration of Pb in an effluent of a galena-enriched mine compared to those at other sites in the stream (Osor Stream, Girona, Spain).
Collapse
Affiliation(s)
- Qiuyue Yang
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
- Universitat
Autònoma de Barcelona, Department
of Material Science, Campus
de la UAB, Plaça Cívica, Bellaterra, 08193 Barcelona, Spain
| | - Bhawna Nagar
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
- École
Polytechnique Fédérale de Lausanne (EPFL) Valais Wallis,
Laboratory of Physical and Analytical Electrochemistry, Rue de l’Industrie 17, 1950 Sion, Switzerland
| | - Ruslán Alvarez-Diduk
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Marc Balsells
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Alessandro Farinelli
- University
of Verona, Department of Computer
Science, Ca Vignal 2,
Strada le Grazie 15, 37134 Verona, Italy
| | - Domenico Bloisi
- University
of Verona, Department of Computer
Science, Ca Vignal 2,
Strada le Grazie 15, 37134 Verona, Italy
- Department
of Mathematics, Computer Science, and Economics, University of Basilicata, 85100 Potenza, Italy
| | - Lorenzo Proia
- BETA Technological
Center, University of Vic-Central University
of Catalonia (UVic-UCC), 08500 Vic, Spain
| | - Carmen Espinosa
- BETA Technological
Center, University of Vic-Central University
of Catalonia (UVic-UCC), 08500 Vic, Spain
- CERM, Center
for the Study of Mediterranean Rivers, University of Vic-Central University
of Catalonia (UVic-UCC), 08560 Manlleu, Spain
| | - Marc Ordeix
- BETA Technological
Center, University of Vic-Central University
of Catalonia (UVic-UCC), 08500 Vic, Spain
- CERM, Center
for the Study of Mediterranean Rivers, University of Vic-Central University
of Catalonia (UVic-UCC), 08560 Manlleu, Spain
| | - Thorsten Knutz
- Go
Systemelektronik GmbH, Falunerweg 1, D-24109 Kiel, Germany
| | - Elisabetta De Vito-Francesco
- University
of Natural Resources and Life Sciences, Institute for Sanitary Engineering
and Water Pollution Control, Muthgasse 18, 1190 Vienna, Austria
| | - Roza Allabashi
- University
of Natural Resources and Life Sciences, Institute for Sanitary Engineering
and Water Pollution Control, Muthgasse 18, 1190 Vienna, Austria
| | - Arben Merkoçi
- Nanobioelectronics
and Biosensors Group, Catalan Institute
of Nanoscience and Nanotechnology (ICN2), CSIC, and The Barcelona
Institute of Science and Technology, Campus UAB, Bellaterra, 08193 Barcelona, Spain
- ICREA, Pg. Lluís
Companys, 23, Barcelona 08010, Spain
| |
Collapse
|
41
|
Li Y, Wu J, Fu L, Wang J. A Fast Bubble Detection Method in Microtubes Based on Pulsed Ultrasound. MICROMACHINES 2021; 12:mi12111402. [PMID: 34832815 PMCID: PMC8625347 DOI: 10.3390/mi12111402] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/09/2021] [Accepted: 11/12/2021] [Indexed: 11/16/2022]
Abstract
In the process of biological microfluidic manipulation, the bubbles generated in the tube will seriously reduce the gauging accuracy. This paper introduces an improving method that can estimate the size of microbubbles in real time. Hence, the measurement data of the liquid volume can be modified according to this method. A microbubble detector based on the pulsed-ultrasound method was studied, including the device structure and the working principle. The assessment formula of the microbubbles in the tube was derived from the simulation results, which adopted the two-phase theory. The digital image processing method was applied to fulfill the microbubble calibration. This detection method was applied to measure the microbubbles in the tube and to modify the flow volume in a timely manner. The results of the experiments showed that this method is effective at improving the microflow gauging accuracy.
Collapse
Affiliation(s)
- Yiqing Li
- School of Mechatronic Engineering, Xi’an Technological University, Xi’an 710021, China; (J.W.); (L.F.)
- Correspondence:
| | - Junwu Wu
- School of Mechatronic Engineering, Xi’an Technological University, Xi’an 710021, China; (J.W.); (L.F.)
| | - Leijie Fu
- School of Mechatronic Engineering, Xi’an Technological University, Xi’an 710021, China; (J.W.); (L.F.)
| | - Jinju Wang
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China;
| |
Collapse
|
42
|
Electrochemical deposition of nickel from aqueous electrolytic baths prepared by dissolution of metallic powder. J Solid State Electrochem 2021. [DOI: 10.1007/s10008-021-05084-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
AbstractA new method of preparation of aqueous electrolyte baths for electrochemical deposition of nickel targets for medical accelerators is presented. It starts with fast dissolution of metallic Ni powder in a HNO3-free solvent. Such obtained raw solution does not require additional treatment aimed to removal nitrates, such as the acid evaporation and Ni salt precipitation-dissolution. It is used directly for preparation of the nickel plating baths after dilution with water, setting up pH value and after possible addition of H3BO3. The pH of the baths ranges from alkaline to acidic. Deposition of 95% of ca. 50 mg of Ni dissolved in the bath takes ca. 3.5 h for the alkaline electrolyte while for the acidic solution it requires ca. 7 h. The Ni deposits obtained from the acidic bath are physically and chemically more stable and possess smoother and crack-free surfaces as compared to the coatings deposited from the alkaline bath. A method of estimation of concentration of H2O2 in the electrolytic bath is also proposed.
Collapse
|
43
|
Pereiro I, Fomitcheva Khartchenko A, Lovchik RD, Kaigala GV. Advection-Enhanced Kinetics in Microtiter Plates for Improved Surface Assay Quantitation and Multiplexing Capabilities. Angew Chem Int Ed Engl 2021; 60:20935-20942. [PMID: 34296491 DOI: 10.1002/anie.202107424] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Indexed: 12/28/2022]
Abstract
Surface assays such as ELISA are pervasive in clinics and research and predominantly standardized in microtiter plates (MTP). MTPs provide many advantages but are often detrimental to surface assay efficiency due to inherent mass transport limitations. Microscale flows can overcome these and largely improve assay kinetics. However, the disruptive nature of microfluidics with existing labware and protocols has narrowed its transformative potential. We present WellProbe, a novel microfluidic concept compatible with MTPs. With it, we show that immunoassays become more sensitive at low concentrations (up to 9× signal improvement in 12× less time), richer in information with 3-4 different kinetic conditions, and can be used to estimate kinetic parameters, minimize washing steps and non-specific binding, and identify compromised results. We further multiplex single-well assays combining WellProbe's kinetic regions with tailored microarrays. Finally, we demonstrate our system in a context of immunoglobulin subclass evaluation, increasingly regarded as clinically relevant.
Collapse
Affiliation(s)
- Iago Pereiro
- IBM Research-Europe, Säumerstrasse 4, 8803, Rüschlikon, Switzerland
| | | | - Robert D Lovchik
- IBM Research-Europe, Säumerstrasse 4, 8803, Rüschlikon, Switzerland
| | - Govind V Kaigala
- IBM Research-Europe, Säumerstrasse 4, 8803, Rüschlikon, Switzerland
| |
Collapse
|
44
|
Pereiro I, Fomitcheva Khartchenko A, Lovchik RD, Kaigala GV. Advection‐Enhanced Kinetics in Microtiter Plates for Improved Surface Assay Quantitation and Multiplexing Capabilities. Angew Chem Int Ed Engl 2021. [DOI: 10.1002/ange.202107424] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Iago Pereiro
- IBM Research—Europe Säumerstrasse 4 8803 Rüschlikon Switzerland
| | | | | | | |
Collapse
|
45
|
Charelli LE, Ferreira JPD, Naveira-Cotta CP, Balbino TA. Engineering mechanobiology through organoids-on-chip: A strategy to boost therapeutics. J Tissue Eng Regen Med 2021; 15:883-899. [PMID: 34339588 DOI: 10.1002/term.3234] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 07/09/2021] [Accepted: 07/21/2021] [Indexed: 12/26/2022]
Abstract
The mechanical environment of living cells is as critical as chemical signaling. Mechanical stimuli play a pivotal role in organogenesis and tissue homeostasis. Unbalances in mechanotransduction pathways often lead to diseases, such as cancer, cystic fibrosis, and neurodevelopmental disorders. Despite its inherent relevance, there is a lack of proper mechanoresponsive in vitro study systems. In this context, there is an urge to engineer innovative, robust, dynamic, and reliable organotypic technologies to better connect cellular processes to organ-level function and multi-tissue cross-talk. Mechanically active organoid-on-chip has the potential to surpass this challenge. These systems converge microfabrication, microfluidics, biophysics, and tissue engineering fields to emulate key features of living organisms, hence, reducing costs, time, and animal testing. In this review, we intended to present cutting-edge organ-on-chip platforms that integrate biomechanical stimuli as well as novel multicellular culture, such as organoids. We focused on its application in two main fields: precision medicine and drug development. Moreover, we also discussed the state of the art for the development of an engineered model to assess patient-derived tumor organoid metastatic potential. Finally, we highlighted the current drawbacks and emerging opportunities to match the industry needs. We envision the use of mechanoresponsive organotypic-on-chip microdevices as an indispensable tool for precision medicine, drug development, disease modeling, tissue engineering, and developmental biology.
Collapse
Affiliation(s)
- Letícia E Charelli
- Nanotechnology Engineering Program, Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering, COPPE, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil.,Mechanical Engineering Department POLI & COPPE/UFRJ, Laboratory of Nano & Microfluidics and Microsystems-LabMEMS, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| | - João P D Ferreira
- Undergraduate Program in Nanotechnology, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| | - Carolina P Naveira-Cotta
- Mechanical Engineering Department POLI & COPPE/UFRJ, Laboratory of Nano & Microfluidics and Microsystems-LabMEMS, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| | - Tiago A Balbino
- Nanotechnology Engineering Program, Alberto Luiz Coimbra Institute for Graduate Studies and Research in Engineering, COPPE, Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, Brazil
| |
Collapse
|
46
|
Zoupanou S, Volpe A, Primiceri E, Gaudiuso C, Ancona A, Ferrara F, Chiriacò MS. SMILE Platform: An Innovative Microfluidic Approach for On-Chip Sample Manipulation and Analysis in Oral Cancer Diagnosis. MICROMACHINES 2021; 12:mi12080885. [PMID: 34442507 PMCID: PMC8401059 DOI: 10.3390/mi12080885] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 07/25/2021] [Accepted: 07/26/2021] [Indexed: 12/22/2022]
Abstract
Oral cancer belongs to the group of head and neck cancers, and, despite its large diffusion, it suffers from low consideration in terms of prevention and early diagnosis. The main objective of the SMILE platform is the development of a low-cost device for oral cancer early screening with features of high sensitivity, specificity, and ease of use, with the aim of reaching a large audience of possible users and realizing real prevention of the disease. To achieve this goal, we realized two microfluidic devices exploiting low-cost materials and processes. They can be used in combination or alone to obtain on-chip sample preparation and/or detection of circulating tumor cells, selected as biomarkers of oral cancer. The realized devices are completely transparent with plug-and-play features, obtained thanks to a highly customized architecture which enables users to easily use them, with potential for a common use among physicians or dentists with minimal training.
Collapse
Affiliation(s)
- Sofia Zoupanou
- Department of Mathematics & Physics E. de Giorgi, University of Salento, Via Arnesano, 73100 Lecce, Italy;
- CNR NANOTEC—Institute of Nanotechnology, Via per Monteroni, 73100 Lecce, Italy;
| | - Annalisa Volpe
- Physics Department, University of Bari “Aldo Moro”, Via Orabona 4, 70126 Bari, Italy; (A.V.); (C.G.); (A.A.)
- Institute for Photonics and Nanotechnologies (IFN), National Council of Research of Italy (CNR), 70126 Bari, Italy
| | | | - Caterina Gaudiuso
- Physics Department, University of Bari “Aldo Moro”, Via Orabona 4, 70126 Bari, Italy; (A.V.); (C.G.); (A.A.)
- Institute for Photonics and Nanotechnologies (IFN), National Council of Research of Italy (CNR), 70126 Bari, Italy
| | - Antonio Ancona
- Physics Department, University of Bari “Aldo Moro”, Via Orabona 4, 70126 Bari, Italy; (A.V.); (C.G.); (A.A.)
- Institute for Photonics and Nanotechnologies (IFN), National Council of Research of Italy (CNR), 70126 Bari, Italy
| | - Francesco Ferrara
- CNR NANOTEC—Institute of Nanotechnology, Via per Monteroni, 73100 Lecce, Italy;
- STMicroelectronics s.r.l., Via per Monteroni, 73100 Lecce, Italy
- Correspondence: (F.F.); (M.S.C.)
| | - Maria Serena Chiriacò
- CNR NANOTEC—Institute of Nanotechnology, Via per Monteroni, 73100 Lecce, Italy;
- Correspondence: (F.F.); (M.S.C.)
| |
Collapse
|
47
|
Läubli NF, Gerlt MS, Wüthrich A, Lewis RTM, Shamsudhin N, Kutay U, Ahmed D, Dual J, Nelson BJ. Embedded Microbubbles for Acoustic Manipulation of Single Cells and Microfluidic Applications. Anal Chem 2021; 93:9760-9770. [PMID: 34228921 PMCID: PMC8295982 DOI: 10.1021/acs.analchem.1c01209] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Accepted: 06/17/2021] [Indexed: 11/29/2022]
Abstract
Acoustically excited microstructures have demonstrated significant potential for small-scale biomedical applications by overcoming major microfluidic limitations. Recently, the application of oscillating microbubbles has demonstrated their superiority over acoustically excited solid structures due to their enhanced acoustic streaming at low input power. However, their limited temporal stability hinders their direct applicability for industrial or clinical purposes. Here, we introduce the embedded microbubble, a novel acoustofluidic design based on the combination of solid structures (poly(dimethylsiloxane)) and microbubbles (air-filled cavity) to combine the benefits of both approaches while minimizing their drawbacks. We investigate the influence of various design parameters and geometrical features through numerical simulations and experimentally evaluate their manipulation capabilities. Finally, we demonstrate the capabilities of our design for microfluidic applications by investigating its mixing performance as well as through the controlled rotational manipulation of individual HeLa cells.
Collapse
Affiliation(s)
- Nino F. Läubli
- Department
of Mechanical and Process Engineering, ETH Zurich, Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
- Molecular
Neuroscience Group, Department of Chemical Engineering and Biotechnology, University of Cambridge, Philippa Fawcett Drive, CB3 0AS Cambridge, United Kingdom
| | - Michael S. Gerlt
- Department
of Mechanical and Process Engineering, ETH Zurich, Mechanics and Experimental Dynamics, Institute of Mechanical Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
| | - Alexander Wüthrich
- Department
of Mechanical and Process Engineering, ETH Zurich, Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
| | - Renard T. M. Lewis
- Department
of Biology, ETH Zurich, Institute of Biochemistry, Otto-Stern-Weg 3, 8093 Zurich, Switzerland
| | - Naveen Shamsudhin
- Department
of Mechanical and Process Engineering, ETH Zurich, Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
| | - Ulrike Kutay
- Department
of Biology, ETH Zurich, Institute of Biochemistry, Otto-Stern-Weg 3, 8093 Zurich, Switzerland
| | - Daniel Ahmed
- Department
of Mechanical and Process Engineering, ETH Zurich, Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
- Department
of Mechanical and Process Engineering, ETH Zurich, Acoustic Robotics Systems Lab, Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | - Jürg Dual
- Department
of Mechanical and Process Engineering, ETH Zurich, Mechanics and Experimental Dynamics, Institute of Mechanical Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
| | - Bradley J. Nelson
- Department
of Mechanical and Process Engineering, ETH Zurich, Multi-Scale Robotics Lab, Institute of Robotics and Intelligent Systems, Tannenstrasse 3, 8092 Zurich, Switzerland
| |
Collapse
|
48
|
Park S, Cho H, Kim J, Han KH. Lateral Degassing Method for Disposable Film-Chip Microfluidic Devices. MEMBRANES 2021; 11:membranes11050316. [PMID: 33925874 PMCID: PMC8146472 DOI: 10.3390/membranes11050316] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 04/21/2021] [Accepted: 04/23/2021] [Indexed: 11/21/2022]
Abstract
It is critical to develop a fast and simple method to remove air bubbles inside microchannels for automated, reliable, and reproducible microfluidic devices. As an active degassing method, this study introduces a lateral degassing method that can be easily implemented in disposable film-chip microfluidic devices. This method uses a disposable film-chip microchannel superstrate and a reusable substrate, which can be assembled and disassembled simply by vacuum pressure. The disposable microchannel superstrate is readily fabricated by bonding a microstructured polydimethylsiloxane replica and a silicone-coated release polymeric thin film. The reusable substrate can be a plate that has no function or is equipped with the ability to actively manipulate and sense substances in the microchannel by an elaborately patterned energy field. The degassing rate of the lateral degassing method and the maximum available pressure in the microchannel equipped with lateral degassing were evaluated. The usefulness of this method was demonstrated using complex structured microfluidic devices, such as a meandering microchannel, a microvortex, a gradient micromixer, and a herringbone micromixer, which often suffer from bubble formation. In conclusion, as an easy-to-implement and easy-to-use technique, the lateral degassing method will be a key technique to address the bubble formation problem of microfluidic devices.
Collapse
|
49
|
Linnemann J, Kanokkanchana K, Tschulik K. Design Strategies for Electrocatalysts from an Electrochemist’s Perspective. ACS Catal 2021. [DOI: 10.1021/acscatal.0c04118] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Julia Linnemann
- Faculty of Chemistry and Biochemistry, Analytical Chemistry II, Ruhr University Bochum, Universitätsstr. 150, ZEMOS, 44801 Bochum, Germany
| | - Kannasoot Kanokkanchana
- Faculty of Chemistry and Biochemistry, Analytical Chemistry II, Ruhr University Bochum, Universitätsstr. 150, ZEMOS, 44801 Bochum, Germany
| | - Kristina Tschulik
- Faculty of Chemistry and Biochemistry, Analytical Chemistry II, Ruhr University Bochum, Universitätsstr. 150, ZEMOS, 44801 Bochum, Germany
| |
Collapse
|
50
|
Ferreira DA, Rothbauer M, Conde JP, Ertl P, Oliveira C, Granja PL. A Fast Alternative to Soft Lithography for the Fabrication of Organ-on-a-Chip Elastomeric-Based Devices and Microactuators. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:2003273. [PMID: 33898174 PMCID: PMC8061392 DOI: 10.1002/advs.202003273] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 12/18/2020] [Indexed: 05/17/2023]
Abstract
Organ-on-a-chip technology promises to revolutionize how pre-clinical human trials are conducted. Engineering an in vitro environment that mimics the functionality and architecture of human physiology is essential toward building better platforms for drug development and personalized medicine. However, the complex nature of these devices requires specialized, time consuming, and expensive fabrication methodologies. Alternatives that reduce design-to-prototype time are needed, in order to fulfill the potential of these devices. Here, a streamlined approach is proposed for the fabrication of organ-on-a-chip devices with incorporated microactuators, by using an adaptation of xurography. This method can generate multilayered, membrane-integrated biochips in a matter of hours, using low-cost benchtop equipment. These devices are capable of withstanding considerable pressure without delamination. Furthermore, this method is suitable for the integration of flexible membranes, required for organ-on-a-chip applications, such as mechanical actuation or the establishment of biological barrier function. The devices are compatible with cell culture applications and present no cytotoxic effects or observable alterations on cellular homeostasis. This fabrication method can rapidly generate organ-on-a-chip prototypes for a fraction of cost and time, in comparison to conventional soft lithography, constituting an interesting alternative to the current fabrication methods.
Collapse
Affiliation(s)
- Daniel A. Ferreira
- i3S – Instituto de Investigação e Inovação em SaúdeUniversidade do PortoRua Alfredo Allen, 208Porto4200‐135Portugal
- INEB – Instituto de Engenharia BiomédicaUniversidade do PortoRua Alfredo Allen, 208Porto4200‐135Portugal
- ICBAS – Instituto de Ciências Biomédicas Abel SalazarUniversidade do PortoRua Jorge de Viterbo Ferreira, 228Porto4050‐313Portugal
| | - Mario Rothbauer
- Department of Orthopedics and Trauma SurgeryKarl Chiari Lab for Orthopedic BiologyMedical University of ViennaWähringer Gürtel, 18‐20Vienna1090Austria
- Institute of Applied Synthetic ChemistryVienna University of Technology (TUW)Getreidmarkt, 9/163Vienna1060Austria
| | - João P. Conde
- Department of BioengineeringInstituto Superior TécnicoUniversidade de LisboaAv. Rovisco Pais, 1Lisboa1049‐001Portugal
- Instituto de Engenharia de Sistemas e Computadores – Microsistemas e Nanotecnologia (INESC MN)Rua Alves Redol, 9Lisboa1000‐029Portugal
| | - Peter Ertl
- Faculty of Technical ChemistryVienna University of Technology (TUW)Getreidemarkt 9Vienna1060Austria
| | - Carla Oliveira
- i3S – Instituto de Investigação e Inovação em SaúdeUniversidade do PortoRua Alfredo Allen, 208Porto4200‐135Portugal
- Ipatimup – Institute of Molecular Pathology and ImmunologyUniversidade do PortoRua Júlio Amaral de Carvalho 45Porto4200‐135Portugal
- Department of PathologyFaculty of MedicineUniversity of PortoAlameda Prof. Hernâni MonteiroPorto4200‐319Portugal
| | - Pedro L. Granja
- i3S – Instituto de Investigação e Inovação em SaúdeUniversidade do PortoRua Alfredo Allen, 208Porto4200‐135Portugal
- INEB – Instituto de Engenharia BiomédicaUniversidade do PortoRua Alfredo Allen, 208Porto4200‐135Portugal
| |
Collapse
|