1
|
Kul A, Budak F, Cetinkaya A, Kaya SI, Al S, Sagirli O, Ozkan SA. Fabrication of a molecularly imprinted polymer-based electrochemical sensor for the selective assay of antipsychotic drug clozapine and performance comparison with LC-MS/MS. Talanta 2025; 281:126810. [PMID: 39241641 DOI: 10.1016/j.talanta.2024.126810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 08/31/2024] [Accepted: 09/03/2024] [Indexed: 09/09/2024]
Abstract
Clozapine (CLO) is an atypical antipsychotic drug indicated for the treatment of schizophrenia. The treatment effectiveness of CLO is better than that of other atypical antipsychotics, and it has the advantage of being able to determine its effectiveness by measuring its concentration in the patient's blood. Thus, sensitive, selective, and accurate determination of CLO in blood is highly significant for treatment monitoring. This study describes the design and fabrication of a molecularly imprinted polymer (MIP)-based electrochemical sensor for CLO determination. This is the first MIP-based electrochemical application in the literature for CLO determination. Employing the thermal polymerization approach, the MIP was formed on the glassy carbon electrode (GCE) using CLO as the template, trans-3-(3-Pyridyl)acrylic acid (3,3-TA) as the functional monomer, and the support of zinc oxide nanoparticles (ZnO NPs). Elaborate characterizations in terms of surface morphology and electrochemistry were performed via scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) methods. An indirect approach was employed to determine CLO in standard solution, real human biological samples, and tablet formulation, using 5 × 10-3 M [Fe(CN)6]3-/4- solution as the redox probe. The limit of detection (LOD) values for the standard solution and serum sample were calculated as 2.9 × 10-11 M and 6.01 × 10-12 M, respectively. These values and recovery studies confirmed the sensor's sensitivity and feasibility. The measurements in the presence of similarly structured compounds (olanzapine and quetiapine fumarate) verified the sensor's superior selectivity. Moreover, the developed sensor's performance was compared and verified using an LC-MS/MS method using the student's t-test and F-test.
Collapse
Affiliation(s)
- Aykut Kul
- Department of Analytical Chemistry, Faculty of Pharmacy, Istanbul University, 34452, Istanbul, Turkiye
| | - Fatma Budak
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkiye; Ankara University, Graduate School of Health Sciences, Ankara, Turkiye
| | - Ahmet Cetinkaya
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkiye
| | - S Irem Kaya
- University of Health Sciences, Gulhane Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkiye
| | - Selen Al
- Department of Analytical Chemistry, Faculty of Pharmacy, Istanbul University, 34452, Istanbul, Turkiye
| | - Olcay Sagirli
- Department of Analytical Chemistry, Faculty of Pharmacy, Istanbul University, 34452, Istanbul, Turkiye.
| | - Sibel A Ozkan
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkiye.
| |
Collapse
|
2
|
Ghanbari MH, Biesalski M, Friedrich O, Etzold BJM. Screen printed 3D microfluidic paper-based and modifier-free electroanalytical device for clozapine sensing. Analyst 2024; 149:5411-5422. [PMID: 39377284 DOI: 10.1039/d4an01136h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/09/2024]
Abstract
The increasing demand in healthcare for accessible and cost-effective analytical tools is driving the development of reliable platforms to the customization of therapy according to individual patient drug serum levels, e.g. of anti-psychotics in schizophrenia. A modifier-free microfluidic paper-based electroanalytical device (μPED) holds promise as a portable, sensitive, and affordable solution. While many studies focus on the working electrode catalysts, improvements by engineering aspects e.g. of the electrode arrangement are less reported. In our study, we demonstrate the enhanced capabilities of the 3D electrode layout of μPED compared to 2D μPED arrangements. We especially show that screen printing can be employed to prepare 3D μPEDs. We conducted a comparison of different 2D and 3D electrode arrangements utilizing cyclic voltammetry in [Fe(CN)6]3-/4-, along with square-wave voltammetry for clozapine (CLZ) sensing. Our findings reveal that the utilization of the 3D μPED leads to an increase in both the electrochemically active surface area and the electron transfer rate. Consequently, this enhancement contributes to improve sensitivity in the CLZ sensing. The 3D μPED clearly outperforms the 2D μPED arrangement in terms of signal strength. With the 3D μPED under the optimized conditions, a linear dose-response for a concentration range from 7.0 to 100 μM was achieved. The limit of detection and sensitivity was determined to be 1.47 μM and 1.69 μA μM-1 cm-2, respectively. This evaluation is conducted in the context of detection and determination of CLZ in a human blood serum sample. These findings underscore the potential of the 3D μPED for future applications in pharmacokinetic analyses and clinical tests to personalize the management of schizophrenia.
Collapse
Affiliation(s)
- Mohammad Hossein Ghanbari
- Friedrich-Alexander-Universität Erlangen-Nürnberg, Power-To-X Technologies, 90762 Fürth, Germany.
- Technische Universität Darmstadt, Ernst-Berl-Institute for Technical Chemistry and Macromolecular Science, Peter-Grünberg-Straße 8, 64287, Darmstadt, Germany
| | - Markus Biesalski
- Technische Universität Darmstadt, Ernst-Berl-Institute for Technical Chemistry and Macromolecular Science, Peter-Grünberg-Straße 8, 64287, Darmstadt, Germany
| | - Oliver Friedrich
- Institute of Medical Biotechnology, Department of Chemical and Biological Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Paul-Gordan-Str. 3, 91052, Erlangen, Germany
| | - Bastian J M Etzold
- Friedrich-Alexander-Universität Erlangen-Nürnberg, Power-To-X Technologies, 90762 Fürth, Germany.
- Technische Universität Darmstadt, Ernst-Berl-Institute for Technical Chemistry and Macromolecular Science, Peter-Grünberg-Straße 8, 64287, Darmstadt, Germany
| |
Collapse
|
3
|
Yu Z, Tang J, Gao Y, Wu D, Chen S, Zeng Y, Tang D, Liu X. Domain-Limited Sub-Nanometer Co Nanoclusters in Defective Nitrogen Doped Carbon Structures for Non-Invasive Drug Monitoring. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2309264. [PMID: 38010948 DOI: 10.1002/smll.202309264] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 11/07/2023] [Indexed: 11/29/2023]
Abstract
In this work, sub-nanometer Co clusters anchored on porous nitrogen-doped carbon (C─N─Co NCs) are successfully prepared by high-temperature annealing and pre-fabricated template strategies for non-invasive sensing of clozapine (CLZ) as an efficient substrate adsorption and electrocatalyst. The introduction of Co sub-nanoclusters (Co NCs) provides enhanced electrochemical performance and better substrate adsorption potential compared to porous and nitrogen-doped carbon structures. Combined with ab initio calculations, it is found that the favorable CLZ catalytic performance with C─N─Co NCs is mainly attributed to possessing a more stable CLZ adsorption structure and lower conversion barriers of CLZ to oxidized state CLZ. An electrochemical sensor for CLZ detection is conceptualized with a wide operating range and high sensitivity, with monitoring capabilities validated in a variety of body fluid environments. Based on the developed CLZ sensing system, the CLZ correlation between blood and saliva and the accuracy of the sensor are investigated by the gold standard method and the rat model of drug administration, paving the way for non-invasive drug monitoring. This work provides new insights into the development of efficient electrocatalysts to enable drug therapy and administration monitoring in personalized healthcare systems.
Collapse
Affiliation(s)
- Zhichao Yu
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Juan Tang
- Key Laboratory for Green Chemistry of Jiangxi Province, Department of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, China
| | - Yuan Gao
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Di Wu
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Shuyun Chen
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Yongyi Zeng
- The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou, 350025, China
| | - Dianping Tang
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, China
| | - Xiaolong Liu
- The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou, 350025, China
| |
Collapse
|
4
|
Navarro-Nateras L, Diaz-Gonzalez J, Aguas-Chantes D, Coria-Oriundo LL, Battaglini F, Ventura-Gallegos JL, Zentella-Dehesa A, Oza G, Arriaga LG, Casanova-Moreno JR. Development of a Redox-Polymer-Based Electrochemical Glucose Biosensor Suitable for Integration in Microfluidic 3D Cell Culture Systems. BIOSENSORS 2023; 13:582. [PMID: 37366947 DOI: 10.3390/bios13060582] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 05/23/2023] [Accepted: 05/23/2023] [Indexed: 06/28/2023]
Abstract
The inclusion of online, in situ biosensors in microfluidic cell cultures is important to monitor and characterize a physiologically mimicking environment. This work presents the performance of second-generation electrochemical enzymatic biosensors to detect glucose in cell culture media. Glutaraldehyde and ethylene glycol diglycidyl ether (EGDGE) were tested as cross-linkers to immobilize glucose oxidase and an osmium-modified redox polymer on the surface of carbon electrodes. Tests employing screen printed electrodes showed adequate performance in a Roswell Park Memorial Institute (RPMI-1640) media spiked with fetal bovine serum (FBS). Comparable first-generation sensors were shown to be heavily affected by complex biological media. This difference is explained in terms of the respective charge transfer mechanisms. Under the tested conditions, electron hopping between Os redox centers was less vulnerable than H2O2 diffusion to biofouling by the substances present in the cell culture matrix. By employing pencil leads as electrodes, the incorporation of these electrodes in a polydimethylsiloxane (PDMS) microfluidic channel was achieved simply and at a low cost. Under flow conditions, electrodes fabricated using EGDGE presented the best performance with a limit of detection of 0.5 mM, a linear range up to 10 mM, and a sensitivity of 4.69 μA mM-1 cm-2.
Collapse
Affiliation(s)
- L Navarro-Nateras
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Jancarlo Diaz-Gonzalez
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Diana Aguas-Chantes
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Lucy L Coria-Oriundo
- Instituto de Química Física de los Materiales, Medio Ambiente y Energía, CONICET-Departamento de Química Inorgánica, Analítica y Química Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires C1428EGA, Argentina
| | - Fernando Battaglini
- Instituto de Química Física de los Materiales, Medio Ambiente y Energía, CONICET-Departamento de Química Inorgánica, Analítica y Química Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires C1428EGA, Argentina
| | - José Luis Ventura-Gallegos
- Departamento de Medicina Genómica y Toxicología Ambiental, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
| | - Alejandro Zentella-Dehesa
- Departamento de Medicina Genómica y Toxicología Ambiental, Instituto de Investigaciones Biomédicas, Universidad Nacional Autónoma de México, Ciudad de México 04510, Mexico
- Unidad de Bioquímica, Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Ciudad de México 14080, Mexico
| | - Goldie Oza
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - L G Arriaga
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| | - Jannu R Casanova-Moreno
- Centro de Investigación y Desarrollo Tecnológico en Electroquímica, Pedro Escobedo 76703, Querétaro, Mexico
| |
Collapse
|
5
|
Application of nickel-doped graphene nanotubes to modified GCE as a sensitive electrochemical sensor for the antipsychotic drug clozapine in spiked human blood serum samples. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2023. [DOI: 10.1007/s13738-023-02745-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
AbstractClozapine (CLZ) is one of the most vital medications for managing schizophrenia, and the timely measurement of CLZ levels has been recognized as an obstacle to the wider use of CLZ. Herein, for the first time, nickel-doped graphene nanotubes (Ni@GRNT) were used to construct an electrochemical CLZ sensor by drop coating Ni@GRNT suspension on a glassy carbon electrode. The Ni@GRNT was synthesized and characterized using X‐ray diffraction, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The electrochemical behavior and influence of different physicochemical factors of sensing electrodes were investigated by using cyclic voltammetry, EIS technique, and differential pulse voltammetry techniques. Also, the catalytic rate constant (kcat) and the transfer coefficient (α) were calculated. The modified electrode illustrated satisfactory linear range, detection limit (LOD), reusability, and reproducibility results. At optimal experimental conditions, measurements can be performed at a broad linear dynamic range of 0.3 nmol L−1–60.0 μmol L−1 CLZ and with a LOD of 0.1 nmol L−1. The sensitivity value was estimated to be 3.06 μA µmol L−1 cm−2. Ultimately, this platform was successfully used for CLZ sensing in spiked human blood serum and tablet samples with an accuracy of > 93%.
Graphical abstract
Collapse
|
6
|
Erşan T, Dilgin DG, Kumrulu E, Kumrulu U, Dilgin Y. Voltammetric Determination of Favipiravir Used as an Antiviral Drug for the Treatment of Covid-19 at Pencil Graphite Electrode. ELECTROANAL 2022; 35:ELAN202200295. [PMID: 36712592 PMCID: PMC9874810 DOI: 10.1002/elan.202200295] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 10/21/2022] [Indexed: 02/01/2023]
Abstract
This work describes the sensitive voltammetric determination of favipiravir (FAV) based on its reduction for the first time with a low-cost and disposable pencil graphite electrode (PGE). In addition, the determination of FAV was also performed based on its oxidation. Differential pulse (DP) voltammograms recorded in 0.5 M H2SO4 for the reduction of FAV show that peak currents increase linearly in the range of 1.0 to 600.0 μM with a limit of detection of 0.35 μM. The acceptable recovery values (98.9-106.0 %) obtained from a pharmaceutical tablet, real human urine, and artificial blood serum samples spiked with FAV confirm the high accuracy of the proposed method.
Collapse
Affiliation(s)
- Teslime Erşan
- Faculty ScienceDepartment of ChemistryÇanakkale Onsekiz Mart University17100TurkeyÇanakkale
| | - Didem Giray Dilgin
- Department of Mathematics and Science EducationFaculty of EducationÇanakkale Onsekiz Mart UniversityÇanakkaleTurkey
| | - Elif Kumrulu
- POLİFARMA İlaç San. ve Tic. A.Ş.ErgeneTekirdağTurkey
| | - Umur Kumrulu
- POLİFARMA İlaç San. ve Tic. A.Ş.ErgeneTekirdağTurkey
| | - Yusuf Dilgin
- Faculty ScienceDepartment of ChemistryÇanakkale Onsekiz Mart University17100TurkeyÇanakkale
| |
Collapse
|
7
|
de Faria LV, Rocha RG, Arantes LC, Ramos DL, Lima CD, Richter EM, P dos Santos WT, Muñoz RA. Cyclic square-wave voltammetric discrimination of the amphetamine-type stimulants MDA and MDMA in real-world forensic samples by 3D-printed carbon electrodes. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Marasca C, Mandrioli R, Sardella R, Vovk T, Armirotti A, Cavalli A, Serretti A, Protti M, Mercolini L. Dried Volumetric Microsampling Approaches for the Therapeutic Drug Monitoring of Psychiatric Patients Undergoing Clozapine Treatment. Front Psychiatry 2022; 13:794609. [PMID: 35722565 PMCID: PMC9198272 DOI: 10.3389/fpsyt.2022.794609] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Accepted: 04/20/2022] [Indexed: 01/18/2023] Open
Abstract
Clozapine is one of the most widely used second-generation antipsychotic drugs (SGAs) for the treatment of schizophrenia. Despite advantages over first-generation drugs, clozapine still shows significant side effects and interindividual variations in efficacy. In order to ensure frequent therapeutic drug monitoring (TDM) and improve the compliance of psychiatric patients undergoing clozapine treatment, two novel dried microsampling approaches based on whole blood and plasma volumetric absorptive microsampling (b-VAMS and p-VAMS) and microfluidic generated-dried blood spot technology (mfDBS) were developed and coupled to HPLC with electrochemical detection (ED). The proposed miniaturized strategies by means of VAMS and microfluidic channel-based devices provide several advantages in terms of collection, storage, and handling compared to classical blood and plasma processing. Satisfactory validation results were obtained for all microsampling platforms, with mean extraction yields >85.1%, precision as relative standard deviation (RSD) < 5.1%, and stability < 4.5% analyte loss after 30 days for p-VAMS; mean extraction yields > 83.4%, precision RSD < 5.4%, and stability < 4.6% analyte loss after 30 days for b-VAMS, and mean extraction yields > 74.0%, precision RSD < 5.6%, and stability < 4.9% analyte loss after 30 days for mfDBS. The original microsampling methodologies have been successfully applied to the blood and plasma collected from five psychiatric patients for the monitoring of the levels of clozapine and its main metabolites, providing robust and reliable quali-quantitative results. Comparisons between results of the two dried microsampling technologies with those obtained by classic fluid plasma analysis were in good agreement and have demonstrated that the proposed miniaturized approaches could be suitable for TDM purposes.
Collapse
Affiliation(s)
- Camilla Marasca
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum – University of Bologna, Bologna, Italy
- Computational and Chemical Biology, Fondazione Istituto Italiano di Tecnologia (IIT), Genoa, Italy
| | - Roberto Mandrioli
- Department for Life Quality Studies (QuVi), Alma Mater Studiorum – University of Bologna, Rimini, Italy
| | - Roccaldo Sardella
- Department of Pharmaceutical Sciences, University of Perugia, Perugia, Italy
| | - Tomaž Vovk
- Faculty of Pharmacy, University of Ljubljana, Ljubljana, Slovenia
| | - Andrea Armirotti
- Analytical Chemistry Lab, Fondazione Istituto Italiano di Tecnologia (IIT), Genoa, Italy
| | - Andrea Cavalli
- Computational and Chemical Biology, Fondazione Istituto Italiano di Tecnologia (IIT), Genoa, Italy
- Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum – University of Bologna, Bologna, Italy
| | - Alessandro Serretti
- Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum – University of Bologna, Bologna, Italy
| | - Michele Protti
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum – University of Bologna, Bologna, Italy
| | - Laura Mercolini
- Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum – University of Bologna, Bologna, Italy
| |
Collapse
|
9
|
Zamani M, Wilhelm T, Furst AL. Perspective-Electrochemical Sensors for Neurotransmitters and Psychiatrics: Steps toward Physiological Mental Health Monitoring. JOURNAL OF THE ELECTROCHEMICAL SOCIETY 2022; 169:047513. [PMID: 37577452 PMCID: PMC10421614 DOI: 10.1149/1945-7111/ac5e42] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
Therapeutic monitoring of neurotransmitters (NTs) and psychiatric medications is essential for the diagnosis and treatment of mental illness. However, in-vivo monitoring of NTs in humans as well as continuous physiological monitoring of psychiatrics have yet to be realized. In pursuit of this goal, there has been a plethora of work to develop electrochemical sensors for both in-vivo NT monitoring as well as in-vitro detection of psychiatric medications. We review these sensors here while discussing next steps needed to achieve concurrent, continuous physiological monitoring of NTs and psychiatric medications as part of a closed-loop feedback system that guides medication administration.
Collapse
Affiliation(s)
- Marjon Zamani
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts—02139, United States of America
| | - Tatum Wilhelm
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts—02139, United States of America
| | - Ariel L. Furst
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts—02139, United States of America
| |
Collapse
|
10
|
de C. Costa BM, Griveau S, Bedioui F, Orlye FD, da Silva JAF, Varenne A. Stereolithography based 3D-printed microfluidic device with integrated electrochemical detection. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.139888] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
11
|
Caruncho-Pérez S, Prado-Comesaña AM, Arellano M, Pazos M, Ángeles Sanromán M, González-Romero E. Methodology for decentralized analysis: detection, quantification and in situ monitoring of pharmaceutical formulations removal by electro-Fenton. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
12
|
Alachkar A, Alhassan S, Senel M. Lab-In-A-Syringe: A Novel Electrochemical Biosensor for On-Site and Real-Time Monitoring of Dopamine in Freely Behaving Mice. ACS Sens 2022; 7:331-337. [PMID: 35006681 DOI: 10.1021/acssensors.1c02525] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
There is a growing demand for real-time analysis and sampling of biofluids on a single low-cost platform in ultralow fluid volumes with robustness. In this study, a microfluidic sensor was developed, manufactured through an additive manufacturing technique, and used for dopamine (DA) measurements. We implemented a biosensing system using pencil graphites (PGEs) integrated into a three-dimensional (3D) printed microfluidic syringe-type device (μSyringe). The amperometry technique was used to monitor the current changes associated with the electrooxidation of DA. The sensing signal was stable and linear in a concentration range of DA between the limit of quantification (0.1 nM) and the upper limit of linearity (500 nM). The μSyringe sensing device is simple, robust, and stable, making it suitable for real-time measurement of DA in cerebrospinal fluid (CSF) from freely moving mice.
Collapse
Affiliation(s)
- Amal Alachkar
- Department of Pharmaceutical Sciences, University of California, Irvine, California 92697-4625, United States
- Institute for Genomics and Bioinformatics, School of Information and Computer Sciences, University of California-Irvine, Irvine, California 92697-4625, United States
- Center for the Neurobiology of Learning and Memory, University of California-Irvine, Irvine, California 92697-4625, United States
| | - Sammy Alhassan
- Department of Pharmaceutical Sciences, University of California, Irvine, California 92697-4625, United States
| | - Mehmet Senel
- Department of Pharmaceutical Sciences, University of California, Irvine, California 92697-4625, United States
- Department of Biochemistry, Faculty of Pharmacy, Biruni University, Istanbul 34010, Turkey
| |
Collapse
|
13
|
Electrocatalytic oxidation and flow injection analysis of formaldehyde at binary metal oxides (Co3O4–NiO and CuO–Co3O4) modified pencil graphite electrodes. MONATSHEFTE FUR CHEMIE 2021. [DOI: 10.1007/s00706-021-02861-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
14
|
Silva AL, Salvador GMDS, Castro SVF, Carvalho NMF, Munoz RAA. A 3D Printer Guide for the Development and Application of Electrochemical Cells and Devices. Front Chem 2021; 9:684256. [PMID: 34277568 PMCID: PMC8283263 DOI: 10.3389/fchem.2021.684256] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 05/31/2021] [Indexed: 12/12/2022] Open
Abstract
3D printing is a type of additive manufacturing (AM), a technology that is on the rise and works by building parts in three dimensions by the deposit of raw material layer upon layer. In this review, we explore the use of 3D printers to prototype electrochemical cells and devices for various applications within chemistry. Recent publications reporting the use of Fused Deposition Modelling (fused deposition modeling®) technique will be mostly covered, besides papers about the application of other different types of 3D printing, highlighting the advances in the technology for promising applications in the near future. Different from the previous reviews in the area that focused on 3D printing for electrochemical applications, this review also aims to disseminate the benefits of using 3D printers for research at different levels as well as to guide researchers who want to start using this technology in their research laboratories. Moreover, we show the different designs already explored by different research groups illustrating the myriad of possibilities enabled by 3D printing.
Collapse
Affiliation(s)
- Ana Luisa Silva
- Grupo de Catálise Ambiental e Sustentabilidade Energética, Instituto de Química, Departamento de Química Geral e Inorgânica, Universidade do Estado do Rio de Janeiro, Maracanã, Rio de Janeiro, Brazil
| | - Gabriel Maia da Silva Salvador
- Grupo de Catálise Ambiental e Sustentabilidade Energética, Instituto de Química, Departamento de Química Geral e Inorgânica, Universidade do Estado do Rio de Janeiro, Maracanã, Rio de Janeiro, Brazil
| | - Sílvia V F Castro
- Núcleo de Pesquisa em Eletroanalítica, Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, Brazil
| | - Nakédia M F Carvalho
- Grupo de Catálise Ambiental e Sustentabilidade Energética, Instituto de Química, Departamento de Química Geral e Inorgânica, Universidade do Estado do Rio de Janeiro, Maracanã, Rio de Janeiro, Brazil
| | - Rodrigo A A Munoz
- Núcleo de Pesquisa em Eletroanalítica, Instituto de Química, Universidade Federal de Uberlândia, Uberlândia, Brazil
| |
Collapse
|
15
|
Senel M, Durmus Z, Alachkar A. Measurement of the Antipsychotic Clozapine Using Reduced Graphene Oxide Nanocomposites‐Au/Pd/Pt Electrodes. ELECTROANAL 2021. [DOI: 10.1002/elan.202060538] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Mehmet Senel
- Department of Pharmaceutical Sciences University of California Irvine CA 92697-4625 United States
| | - Zehra Durmus
- Centre for Innovation Competence SiLi-nano Martin Luther University Halle-Wittenberg 06120 Halle (Salle) Germany
| | - Amal Alachkar
- Department of Pharmaceutical Sciences University of California Irvine CA 92697-4625 United States
| |
Collapse
|