1
|
Henderson A, Heaney LM, Rankin-Turner S. Ambient ionisation mass spectrometry for drug and toxin analysis: A review of the recent literature. Drug Test Anal 2024; 16:1323-1344. [PMID: 38326879 DOI: 10.1002/dta.3644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/17/2023] [Accepted: 12/28/2023] [Indexed: 02/09/2024]
Abstract
Ambient ionisation mass spectrometry (AIMS) is a form of mass spectrometry whereby analyte ionisation occurs outside of a vacuum source under ambient conditions. This enables the direct analysis of samples in their native state, with little or no sample preparation and without chromatographic separation. The removal of these steps facilitates a much faster analytical process, enabling the direct analysis of samples within minutes if not seconds. Consequently, AIMS has gained rapid popularity across a diverse range of applications, in particular the analysis of drugs and toxins. Numerous fields rely upon mass spectrometry for the detection and identification of drugs, including clinical diagnostics, forensic chemistry, and food safety. However, all of these fields are hindered by the time-consuming and laboratory-confined nature of traditional techniques. As such, the potential for AIMS to resolve these challenges has resulted in a growing interest in ambient ionisation for drug and toxin analysis. Since the early 2000s, forensic science, diagnostic testing, anti-doping, pharmaceuticals, environmental analysis and food safety have all seen a marked increase in AIMS applications, foreshadowing a new future for drug testing. In this review, some of the most promising AIMS techniques for drug analysis will be discussed, alongside different applications of AIMS published over a 5-year period, to provide a summary of the recent research activity for ambient ionisation for drug and toxin analysis.
Collapse
Affiliation(s)
- Alisha Henderson
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Liam M Heaney
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Stephanie Rankin-Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
2
|
García-Rojas NS, Guillén-Alonso H, MacKay S, Torres-Calzada C, Soto-Rodriguez LD, Winkler R, Wishart DS. The Open SprayBot: A high-throughput paper spray mass spectrometry platform for disease screening. HARDWAREX 2024; 19:e00551. [PMID: 39071222 PMCID: PMC11283016 DOI: 10.1016/j.ohx.2024.e00551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 06/07/2024] [Accepted: 06/29/2024] [Indexed: 07/30/2024]
Abstract
Newborn disease screening increases survival, improves quality of life and reduces treatment costs for healthcare systems. Mass spectrometry (MS) is an effective method for metabolic screening. However, conventional analytical methods require biofluid handling and cooling conditions during transport, making the logistics difficult and expensive, especially for remote regions. 'Paper-spray' (PS) ionization generates a charged solvent spray from samples deposited on paper strips. Therefore, samples can be applied on a suitable matrix and shipped as dried spots to diagnostic laboratories with standard postal or messenger services. We built a robotic platform, the 'Open SprayBot', to automatically analyze paper-deposited samples via PS-MS and increase the sample throughput. The system is operated via RUMBA32 and Arduino Mega boards. A commercial syringe pump and power supply provide solvent application and electrical current required for PS-MS. The usability of the Open SprayBot was demonstrated by quantifying palmitoyl-l-carnitine, a common biomarker in newborn screening.
Collapse
Affiliation(s)
- Nancy Shyrley García-Rojas
- Laboratorio de Análisis Bioquímico e Instrumental, Unidad de Genómica Avanzada, Cinvestav, Km. 9.6 Libramiento Norte, Carretera Irapuato-León, Irapuato, Guanajuato, México
- Department of Biological Science, University of Alberta, Edmonton, Canada
| | - Héctor Guillén-Alonso
- Laboratorio de Análisis Bioquímico e Instrumental, Unidad de Genómica Avanzada, Cinvestav, Km. 9.6 Libramiento Norte, Carretera Irapuato-León, Irapuato, Guanajuato, México
- Department of Biochemical Engineering, National Technological Institute, Celaya, Mexico
| | - Scott MacKay
- Department of Biological Science, University of Alberta, Edmonton, Canada
| | | | - Leonardo Daniel Soto-Rodriguez
- Laboratorio de Análisis Bioquímico e Instrumental, Unidad de Genómica Avanzada, Cinvestav, Km. 9.6 Libramiento Norte, Carretera Irapuato-León, Irapuato, Guanajuato, México
| | - Robert Winkler
- Laboratorio de Análisis Bioquímico e Instrumental, Unidad de Genómica Avanzada, Cinvestav, Km. 9.6 Libramiento Norte, Carretera Irapuato-León, Irapuato, Guanajuato, México
| | - David S. Wishart
- Department of Biological Science, University of Alberta, Edmonton, Canada
- Department of Computing Science, University of Alberta, Edmonton, Canada
| |
Collapse
|
3
|
Bondzie EH, Adehinmoye A, Molnar BT, Fedick PW, Mulligan CC. Application of a Modified 3D-PCSI-MS Ion Source to On-Site, Trace Evidence Processing via Integrated Vacuum Collection. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:82-89. [PMID: 38064434 DOI: 10.1021/jasms.3c00317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Trace evidence, including hair, fibers, soil/dust, and gunshot residue (GSR), can be recovered from a crime scene to help identify or associate a suspect with illegal activities via physical, chemical, and biological testing. Vacuum collection is one technique that is employed in recovering such trace evidence but is often done so in a targeted manner, leaving other complementary, chemical-specific information unexamined. Here, we describe a modified 3D-printed cone spray ionization (3D-PCSI) source with integrated vacuum collection for on-site, forensic evidence screening, allowing the processing of targeted physical traces and nontargeted chemical species alike. The reported form factor allows sample collection, onboard extraction, filtration, and spray-based ionization in a singular vessel with minimal handling of evidence by the operator. Utilizing authentic forensic evidence types and portable MS instrumentation, this new method was characterized through systematic studies that replicate CSI applications. Reliability in the form of false positive/negative response rates was determined from a modest, user-blinded data set, and other attributes, such as collection efficacy and detection limit, were examined.
Collapse
Affiliation(s)
- Ebenezer H Bondzie
- Department of Chemistry, Illinois State University, Normal, Illinois 61704, United States
| | - Adewale Adehinmoye
- Department of Chemistry, Illinois State University, Normal, Illinois 61704, United States
| | - Brian T Molnar
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, United States
| | - Patrick W Fedick
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, United States
| | - Christopher C Mulligan
- Department of Chemistry, Illinois State University, Normal, Illinois 61704, United States
| |
Collapse
|
4
|
Samples R, Mukoyama R, Shaffer J, Mikucki J, Giddings LA. OpenASAP: An affordable 3D printed atmospheric solids analysis probe (ASAP) mass spectrometry system for direct analysis of solid and liquid samples. HARDWAREX 2023; 16:e00490. [PMID: 38186665 PMCID: PMC10767633 DOI: 10.1016/j.ohx.2023.e00490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 09/29/2023] [Accepted: 11/10/2023] [Indexed: 01/09/2024]
Abstract
Atmospheric Solids Analysis Probe (ASAP) mass spectrometry is a versatile technique allowing direct sampling of solid and liquid samples, but its adoption is limited due to the high cost of commercial ASAP systems. To address this, we present OpenASAP, an open-source ASAP system for mass spectrometers that can be fabricated for $20 or less using 3D-printing. Our design is readily adaptable to instruments from different manufacturers and can be produced with a variety of additive manufacturing techniques on consumer-grade 3D-printers. The probe allows for rapid sampling of solid and liquid samples without sample preparation, making it useful for high throughput screening, investigating spatial localization and function of analytes in biological samples, and incorporating mass spectrometry in instructional settings. We demonstrate its effectiveness by obtaining mass spectra of three natural product standards at levels as low as 10 ng/ml in liquid samples, and detecting these metabolites in microbial cultures that are difficult to analyze due to complex sample matrices or analyte properties. Furthermore, we demonstrate direct sampling of thin layer chromatography (TLC) spots of these cultures.
Collapse
Affiliation(s)
- Robert Samples
- Biochemistry Program, Smith College, 100 Green St Northampton, MA 01063, USA
| | - Riko Mukoyama
- Biochemistry Program, Smith College, 100 Green St Northampton, MA 01063, USA
| | - Jacob Shaffer
- Department of Microbiology, University of Tennessee at Knoxville, Knoxville, TN 37902, USA
| | - Jill Mikucki
- Department of Microbiology, University of Tennessee at Knoxville, Knoxville, TN 37902, USA
| | - Lesley-Ann Giddings
- Biochemistry Program, Smith College, 100 Green St Northampton, MA 01063, USA
| |
Collapse
|
5
|
Yishai Aviram L, Dagan S, Hindi A, Chapman S, Gez R, Drug E. Monitoring Exposure to Five Chemical Warfare Agents Using the Dried Urine Spot Technique and Liquid Chromatography-Mass Spectrometry/Mass Spectrometry-In Vivo Determination of Sarin Metabolite in Mice. Molecules 2023; 28:7687. [PMID: 38067417 PMCID: PMC10707994 DOI: 10.3390/molecules28237687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 11/05/2023] [Accepted: 11/14/2023] [Indexed: 12/18/2023] Open
Abstract
Dried urine spot (DUS) is a micro-sample collection technique, known for its advantages in handling, storage and shipping. It also uses only a small volume of urine, an essential consideration in working with small animals, or in acute medical situations. Alkyl-phosphonic acids are the direct and indicative metabolites of organophosphorus chemical warfare agents (OP-CWAs) and are present in blood and urine shortly after exposure. They are therefore crucially important for monitoring casualties in war and terror scenarios. We report here a new approach for the determination of the metabolites of five CWAs in urine using DUS. The method is based on a simple and rapid sample preparation, using only 50 µL of urine, spotted and dried on DBS paper, extracted using 300 µL methanol/water and analyzed via targeted LC-MS/MS. The detection limits for the five CWAs, sarin (GB), soman (GD), cyclosarin (GF), VX and RVX in human urine were from 0.5 to 5 ng/mL. Recoveries of (40-80%) were obtained in the range of 10-300 ng/mL, with a linear response (R2 > 0.964, R > 0.982). The method is highly stable, even with DUS samples stored up to 5 months at room temperature before analysis. It was implemented in a sarin in vivo exposure experiment on mice, applied for the time course determination of isopropyl methylphosphonic acid (IMPA, sarin hydrolysis product) in mice urine. IMPA was detectable even with samples drawn 60 h after the mice's (IN) exposure to 1 LD50 sarin. This method was also evaluated in a non-targeted screening for multiple potential CWA analogs (LC-Orbitrap HRMS analysis followed by automatic peak detection and library searches). The method developed here is applicable for rapid CWA casualty monitoring.
Collapse
Affiliation(s)
- Lilach Yishai Aviram
- Department of Analytical Chemistry, Israel Institute for Biological Research (IIBR), Ness Ziona 7410001, Israel; (S.D.); (A.H.); (S.C.); (R.G.); (E.D.)
| | | | | | | | | | | |
Collapse
|
6
|
McDaniel TJ, Holtz JM, Bondzie EH, Overfelt M, Fedick PW, Mulligan CC. Rapid screening of high-priority N-nitrosamines in pharmaceutical, forensic, and environmental samples with paper spray ionization and filter cone spray ionization-mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2023; 37 Suppl 1:e9493. [PMID: 36775811 DOI: 10.1002/rcm.9493] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 02/07/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
RATIONALE The burgeoning concern of N-nitrosamine (NAM) contamination found in various pharmaceutical compositions has increased the demand for rapid and reliable screening methods to better assess the breadth of the problem. These carcinogenic compounds are also found in food, water, and soil, and they have been used in poison-related homicides. METHODS A combination of complementary, ambient ionization methods, paper spray ionization (PSI) and filter cone spray ionization (FCSI)-mass spectrometry (MS), was characterized towards trace-level residue screening of select NAMs (e.g., N-nitrosodimethylamine, N-nitrosodiethylamine, N-nitrosodibutylamine) directly from complex and problematic matrices of interest, including prescription and over-the-counter tablets, drinking water, soil, and consumable goods. Spectral data for analyte confirmation and detection limit studies were collected using a Thermo LCQ Fleet ion trap mass spectrometer. RESULTS PSI-MS and FCSI-MS readily produced mass spectral data marked by their simplicity (e.g., predominantly protonated molecular ions observed) and congruence with traditional electrospray ionization mass spectra in under 2 min. per sample. Both methods proved robust to the complex matrices tested, yielding ion signatures for target NAMs, as well as active pharmaceutical ingredients for analyzed tablets, flavorants inherent to food products, etc. Low part-per-million detection limits were observed but were shown dependent on sample composition. CONCLUSIONS PSI-MS and FCSI-MS were successful in detecting trace-level NAMS in complex liquid- and solid-phase matrices with little to no prior preparation. This work suggests that these methodologies can provide a means for assessing problematic pharmaceutical adulterants/degradants for expedited quality control, as well as enhancing environmental stewardship efforts and forensic investigations.
Collapse
Affiliation(s)
| | - Jessica M Holtz
- Department of Chemistry, Illinois State University, Normal, IL, USA
| | | | - Makoy Overfelt
- Department of Chemistry, Illinois State University, Normal, IL, USA
| | - Patrick W Fedick
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, CA, USA
| | | |
Collapse
|
7
|
Rankin‐Turner S, Reynolds JC, Turner MA, Heaney LM. Applications of ambient ionization mass spectrometry in 2021: An annual review. ANALYTICAL SCIENCE ADVANCES 2022; 3:67-89. [PMID: 38715637 PMCID: PMC10989594 DOI: 10.1002/ansa.202100067] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/17/2022] [Accepted: 02/27/2022] [Indexed: 06/26/2024]
Abstract
Ambient ionization mass spectrometry (AIMS) has revolutionized the field of analytical chemistry, enabling the rapid, direct analysis of samples in their native state. Since the inception of AIMS almost 20 years ago, the analytical community has driven the further development of this suite of techniques, motivated by the plentiful advantages offered in addition to traditional mass spectrometry. Workflows can be simplified through the elimination of sample preparation, analysis times can be significantly reduced and analysis remote from the traditional laboratory space has become a real possibility. As such, the interest in AIMS has rapidly spread through analytical communities worldwide, and AIMS techniques are increasingly being integrated with standard laboratory operations. This annual review covers applications of AIMS techniques throughout 2021, with a specific focus on AIMS applications in a number of key fields of research including disease diagnostics, forensics and security, food safety testing and environmental sciences. While some new techniques are introduced, the focus in AIMS research is increasingly shifting from the development of novel techniques toward efforts to improve existing AIMS techniques, particularly in terms of reproducibility, quantification and ease-of-use.
Collapse
Affiliation(s)
- Stephanie Rankin‐Turner
- W. Harry Feinstone Department of Molecular Microbiology and ImmunologyJohns Hopkins Bloomberg School of Public HealthJohns Hopkins UniversityBaltimoreMarylandUSA
| | - James C. Reynolds
- Department of ChemistryLoughborough UniversityLoughboroughLeicestershireUK
| | - Matthew A. Turner
- Department of ChemistryLoughborough UniversityLoughboroughLeicestershireUK
| | - Liam M. Heaney
- School of SportExercise and Health SciencesLoughborough UniversityLoughboroughLeicestershireUK
| |
Collapse
|
8
|
García-Rojas NS, Guillén-Alonso H, Martínez-Jarquín S, Moreno-Pedraza A, Soto-Rodríguez LD, Winkler R. Build, Share and Remix: 3D Printing for Speeding Up the Innovation Cycles in Ambient Ionisation Mass Spectrometry (AIMS). Metabolites 2022; 12:185. [PMID: 35208258 PMCID: PMC8874637 DOI: 10.3390/metabo12020185] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/13/2021] [Accepted: 10/18/2021] [Indexed: 02/01/2023] Open
Abstract
Ambient ionisation mass spectrometry (AIMS) enables studying biological systems in their native state and direct high-throughput analyses. The ionisation occurs in the physical conditions of the surrounding environment. Simple spray or plasma-based AIMS devices allow the desorption and ionisation of molecules from solid, liquid and gaseous samples. 3D printing helps to implement new ideas and concepts in AIMS quickly. Here, we present examples of 3D printed AIMS sources and devices for ion transfer and manipulation. Further, we show the use of 3D printer parts for building custom AIMS sampling robots and imaging systems. Using 3D printing technology allows upgrading existing mass spectrometers with relatively low cost and effort.
Collapse
Affiliation(s)
- Nancy Shyrley García-Rojas
- Department of Biotechnology and Biochemistry, Center for Research and Advanced Studies (CINVESTAV) Irapuato, Km. 9.6 Libramiento Norte Carr. Irapuato-León, Irapuato 36824, Mexico; (N.S.G.-R.); (H.G.-A.); (A.M.-P.); (L.D.S.-R.)
| | - Héctor Guillén-Alonso
- Department of Biotechnology and Biochemistry, Center for Research and Advanced Studies (CINVESTAV) Irapuato, Km. 9.6 Libramiento Norte Carr. Irapuato-León, Irapuato 36824, Mexico; (N.S.G.-R.); (H.G.-A.); (A.M.-P.); (L.D.S.-R.)
- Department of Biochemical Engineering, Nacional Technological Institute, Celaya 38010, Mexico
| | | | - Abigail Moreno-Pedraza
- Department of Biotechnology and Biochemistry, Center for Research and Advanced Studies (CINVESTAV) Irapuato, Km. 9.6 Libramiento Norte Carr. Irapuato-León, Irapuato 36824, Mexico; (N.S.G.-R.); (H.G.-A.); (A.M.-P.); (L.D.S.-R.)
| | - Leonardo D. Soto-Rodríguez
- Department of Biotechnology and Biochemistry, Center for Research and Advanced Studies (CINVESTAV) Irapuato, Km. 9.6 Libramiento Norte Carr. Irapuato-León, Irapuato 36824, Mexico; (N.S.G.-R.); (H.G.-A.); (A.M.-P.); (L.D.S.-R.)
| | - Robert Winkler
- Department of Biotechnology and Biochemistry, Center for Research and Advanced Studies (CINVESTAV) Irapuato, Km. 9.6 Libramiento Norte Carr. Irapuato-León, Irapuato 36824, Mexico; (N.S.G.-R.); (H.G.-A.); (A.M.-P.); (L.D.S.-R.)
| |
Collapse
|
9
|
Miniature mass spectrometer-based point-of-care assay for cabotegravir and rilpivirine in whole blood. Anal Bioanal Chem 2022; 414:3387-3395. [PMID: 35169905 PMCID: PMC9018536 DOI: 10.1007/s00216-022-03954-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 01/07/2022] [Accepted: 02/01/2022] [Indexed: 11/01/2022]
Abstract
HIV prevention and treatment with injectable cabotegravir and/or rilpivirine administered once every 4 to 8 weeks is an attractive alternative to daily therapy. Prescribed dosage and drug concentrations in plasma are based on patient data collected in clinical trials, but actual patients are expected to exhibit more variability in drug concentrations, which is important to quantify. Here, we demonstrate the first quantitative point-of-care assay with a miniature mass spectrometer to assess these drug concentrations in whole blood. Quantitative performance is obtained using paper spray ionization in combination with tandem mass spectrometry (MS/MS) in the clinically relevant concentration range of both drugs. Limits of quantitation (LoQs) of cabotegravir and rilpivirine are measured to be 750 ng/mL and 20 ng/mL, respectively. The assay turnaround time is < 4 min, and strong linear relationships are established between MS/MS responses and concentration, with percentage of relative standard deviations (RSDs) that are <15% at concentrations above the LoQs. The speed, portability, low power consumption, and specificity offered by the miniature instrument should make it an appropriate platform for measuring drug concentrations in a walk-in clinic using small volumes of patient blood.
Collapse
|