1
|
Zhang J, Chen Y, Qi J, Miao Q, Deng D, He H, Yan X, Luo L. A paper-based ratiometric fluorescence sensor based on carbon dots modified with Eu 3+ for the selective detection of tetracycline in seafood aquaculture water. Analyst 2024; 149:1571-1578. [PMID: 38285427 DOI: 10.1039/d3an02133e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2024]
Abstract
Paper-based ratiometric fluorescence sensors are normally prepared using two or more types of fluorescent materials on a paper chip for simple, low-cost and fast detection. However, the choice of multi-step and one-step modifications on the paper chip affects the analytical performance. Herein, a novel paper-based dual-emission ratiometric fluorescence sensor was designed for the selective detection of tetracycline (TC). Carbon dots (CDs) modified with Eu3+ were combined with a sealed paper-based microfluidic chip by two methods: one-step grafting of CDs-Eu3+ on paper and step-by-step grafting of CDs and Eu3+ on paper. The analytical performance was studied and optimized respectively. The red fluorescence of Eu3+ at 450 nm is enhanced and the blue fluorescence of CDs at 617 nm is quenched by energy transfer in the presence of TC. Under optimal conditions, TC is selectively determined in the linear range from 0.1 μM to 100 μM with a detection limit of 0.03 μM by the step-by-step grafting method. In addition, the sealed paper chip could effectively prevent pollution and volatilization from the reagent. This technique has been used to analyze TC in seafood aquaculture water with satisfactory results.
Collapse
Affiliation(s)
- Jialu Zhang
- School of Medicine, Shanghai University, Shanghai 200444, PR China
| | - Yuanyuan Chen
- College of Sciences, Shanghai University, Shanghai 200444, PR China.
| | - Ji Qi
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Shandong Provincial Key Laboratory of Coastal Environmental Processes, Research Centre for Coastal Environmental Engineering and Technology, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China.
| | - Qinglan Miao
- College of Sciences, Shanghai University, Shanghai 200444, PR China.
| | - Dongmei Deng
- College of Sciences, Shanghai University, Shanghai 200444, PR China.
| | - Haibo He
- College of Sciences, Shanghai University, Shanghai 200444, PR China.
| | - Xiaoxia Yan
- College of Sciences, Shanghai University, Shanghai 200444, PR China.
| | - Liqiang Luo
- College of Sciences, Shanghai University, Shanghai 200444, PR China.
| |
Collapse
|
2
|
Wang X, Zhang R, Ma X, Xu Z, Ma M, Zhang T, Ma Y, Shi F. Carbon dots@noble metal nanoparticle composites: research progress report. Analyst 2024; 149:665-688. [PMID: 38205593 DOI: 10.1039/d3an01580g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
Carbon dots@noble metal nanoparticle composites are formed by combining carbon dots and metal nanoparticles using various strategies. Carbon dots exhibit a reducing ability and function as stabilisers; consequently, metal-ion solutions can be directly reduced by them to synthesise gold, silver, and gold-silver alloy particles. Carbon dots@gold/silver/gold-silver particle composites have demonstrated the potential for several practical applications owing to their superior properties and simple preparation process. Until now, several review articles have been published to summarise fluorescent carbon dots or noble metal nanomaterials. Compared with metal-free carbon dots, carbon dots@noble metal nanoparticles have a unique morphology and structure, resulting in new physicochemical properties, which allow for sensing, bioimaging, and bacteriostasis applications. Therefore, to promote the effective development of carbon dots@noble metal nanoparticle composites, this paper primarily reviews carbon dots@gold/silver/gold-silver alloy nanoparticle composites for the first time in terms of the following aspects. (1) The synthesis strategies of carbon dots@noble metal nanoparticle composites are outlined. The principle and function of carbon dots in the synthesis strategies are examined. The advantages and disadvantages of these methods and composites are analysed. (2) The characteristics and properties of such composites are described. (3) The applications of these composite materials are summarised. Finally, the potentials and limitations of carbon dots@noble metal nanoparticle composites are discussed, thus laying the foundation for their further development.
Collapse
Affiliation(s)
- Xuejing Wang
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Renyin Zhang
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Xiaoyu Ma
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Zhihua Xu
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Mingze Ma
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Tieying Zhang
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Yu Ma
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| | - Feng Shi
- College of Life Sciences, Shihezi University, Shihezi 832003, China.
| |
Collapse
|
3
|
Alwael H, Al-Raimi DS, Al-Ahmary KM, Nasef HA, Alharthi AS, Abduljabbar TN, Mujawar LH, Danish EY, Soomro MT, El-Shahawi MS. An Eco-Friendly, Interference, and Solvent Free Surfactant-Assisted Dual-Wavelength β-CorrectionSpectrometric Method for Total Determination and Speciation of Cu 2+ Ions in Water. Int J Anal Chem 2023; 2023:5001869. [PMID: 37954135 PMCID: PMC10640129 DOI: 10.1155/2023/5001869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 07/11/2023] [Accepted: 09/20/2023] [Indexed: 11/14/2023] Open
Abstract
Spectral interference through the presence of uninformative variables, excess reagents, and complications in the refinement of the analyte signal is common in the quest to identify complex species in real samples. Therefore, an economical green, facile, and sensitive strategy has been developed for Cu2+ detection using the anionic surfactant sodium dodecylsulphate- (SDS-) assisted dual-wavelength β-correction spectrophotometric strategy combined with the chromogenic reagent zincon (ZI). The low limits of detection (LOD) and quantification (LOQ) of Cu2+ using ordinary (single wavelength) spectrophotometry were 0.19 (3.02) and 0.63 (10.0) μgmL-1, and these values were improved to 0.08 (1.27) and 0.26 μgmL-1 (4.12 μM)) using β-correction (dual wavelength) spectrophotometry, respectively. The LOD and LOQ were improved from 0.08 (1.27) and 0.26 (4.12) μgmL-1 to 0.02 (0.32) and 0.08 μgmL-1 (1.27 μM) using SDS-assisted dual-β-correction spectrometry, respectively. Ringbom, s, and the corrected absorbance (Ac) versus Cu2+ concentration plots were linear over the concentration range 1.10-2.4 (17.4-38.1) and 0.50-2.40 μgmL-1 (7.94-38.1 μM), respectively. Sandell's sensitivity index of 3.0 × 10-3 μg/cm2 was achieved. The selectivity was further confirmed via monitoring the impact of common diverse ions and surfactants on the corrected absorbance. Total determination and Cu2+ speciation in water were favorably implemented and validated by ICP-OES at 95% (P=0.05). Satisfactory Cu2+ recoveries in tap (92.2-98.0%) and mineral (105-111.0%) water samples were achieved. The sensing system is simple, reliable, sensitive, and selective for Cu2+ detection.
Collapse
Affiliation(s)
- Hassan Alwael
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Doaa S. Al-Raimi
- Department of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi Arabia
| | - Khairia M. Al-Ahmary
- Department of Chemistry, College of Science, University of Jeddah, Jeddah, Saudi Arabia
| | - Hany A. Nasef
- Department of Basic Sciences, ta Higher Institute for Engineering and Technology, Mansoura 35111, Egypt
| | - Amal S. Alharthi
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Tharawat N. Abduljabbar
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Liyakat H. Mujawar
- Center of Excellence in Environmental Studies, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
| | - Ekram Y. Danish
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| | - Mohammad T. Soomro
- Center of Excellence in Environmental Studies, King Abdulaziz University, P.O. Box 80216, Jeddah 21589, Saudi Arabia
| | - Mohammad S. El-Shahawi
- Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia
| |
Collapse
|
4
|
Bao H, Liu Y, Li H, Qi W, Sun K. Luminescence of carbon quantum dots and their application in biochemistry. Heliyon 2023; 9:e20317. [PMID: 37790961 PMCID: PMC10543222 DOI: 10.1016/j.heliyon.2023.e20317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 08/17/2023] [Accepted: 09/19/2023] [Indexed: 10/05/2023] Open
Abstract
Similar to fullerenes, carbon nanotubes and graphene, carbon dots (CDs) are causing a lot of research work in their own right. CDs are a type of surface-passivated quantum dot that contain carbon atoms. Their distinctive characteristics, such as luminescent emission that varies with size and wavelength, resistance to photobleaching, easy biological binding, lack of toxicity, and economical production without the need for intricate synthetic processes, have led to a noteworthy surge in attention within the research community. Different techniques can be utilized to create these CDs, spanning from basic candle burning to laser ablation. This review article delves into the principles of fluorescence technology, providing insights into how different synthesis methods of quantum dots impact their luminescent properties. Additionally, it highlights the latest applications of quantum dots in catalysis and biomedical fields, with special emphasis on the current status of luminescent properties in biology and chemistry. Towards the end, the article discusses the limitations of quantum dots in current practical applications, pointing out that CDs hold promising potential for future applications.
Collapse
Affiliation(s)
- Haili Bao
- Department of General Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| | - Yihao Liu
- Department of General Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| | - He Li
- Beijing University of Chemical Technology, Beijing, China
| | - Wenxin Qi
- School of Life Sciences, Shanghai University, Shanghai, China
| | - Keyan Sun
- Department of General Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, China
| |
Collapse
|
5
|
Mettakoonpitak J, Sawatdichai N, Thepnuan D, Siripinyanond A, Henry CS, Chantara S. Microfluidic paper-based analytical devices for simultaneous detection of oxidative potential and copper in aerosol samples. Mikrochim Acta 2023; 190:241. [PMID: 37243836 DOI: 10.1007/s00604-023-05819-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/02/2023] [Indexed: 05/29/2023]
Abstract
The potential reach of point-of-care (POC) diagnostics into daily routines for exposure to reactive oxygen species (ROS) and Cu in aerosolized particulate matter (PM) demands that microfluidic paper-based analytical devices (μPADs) take into consideration the simple detection of these toxic PM components. Here, we propose μPADs with a dual-detection system for simultaneous ROS and Cu(II) detection. For colorimetric ROS detection, the glutathione (GSH) assay with a folding design to delay the reaction yielded complete ROS and GSH oxidation, and improved homogeneity of color development relative to using the lateral flow pattern. For electrochemical Cu(II) determination, 1,10-phenanthroline/Nafion modified graphene screen-printed electrodes showed ability to detect Cu(II) down to pg level being low enough to be applied to PM analysis. No intra- and inter-interference affecting both systems were found. The proposed μPADs obtained LODs for 1,4-naphthoquinone (1,4-NQ), used as the ROS representative, and Cu(II) of 8.3 ng and 3.6 pg, respectively and linear working ranges of 20 to 500 ng for ROS and 1 × 10-2 to 2 × 102 ng for Cu(II). Recovery of the method was between 81.4 and 108.3% for ROS and 80.5-105.3% for Cu(II). Finally, the sensors were utilized for simultaneous ROS and Cu(II) determination in PM samples and the results statistically agreed with those using the conventional methods at 95% confidence.
Collapse
Affiliation(s)
- Jaruwan Mettakoonpitak
- Department of Chemistry, Faculty of Science and Technology, Rambhai Barni Rajabhat University, Chantaburi, 22000, Thailand.
| | - Nalatthaporn Sawatdichai
- Department of Chemistry, Faculty of Science and Technology, Rambhai Barni Rajabhat University, Chantaburi, 22000, Thailand
| | - Duangduean Thepnuan
- Department of Chemistry, Faculty of Science and Technology, Chiang Mai Rajabhat University, Chiang Mai, 50300, Thailand
| | - Atitaya Siripinyanond
- Department of Chemistry and Center for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Road, Bangkok, 10400, Thailand
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado, 80523, USA
| | - Somporn Chantara
- Environmental Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand
| |
Collapse
|
6
|
Zhang J, Chen H, Xu K, Deng D, Zhang Q, Luo L. Current Progress of Ratiometric Fluorescence Sensors Based on Carbon Dots in Foodborne Contaminant Detection. BIOSENSORS 2023; 13:233. [PMID: 36831999 PMCID: PMC9953573 DOI: 10.3390/bios13020233] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/26/2022] [Revised: 01/30/2023] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Carbon dots (CDs) are widely used in the detection of foodborne contaminants because of their biocompatibility, photoluminescence stability, and ease of chemical modification. In order to solve the interference problem of complexity in food matrices, the development of ratiometric fluorescence sensors shows great prospects. In this review, the progress of ratiometric fluorescence sensors based on CDs in foodborne contaminant detection in recent years will be summarized, focusing on the functionalized modification of CDs, the fluorescence sensing mechanism, the types of ratiometric fluorescence sensors, and the application of portable devices. In addition, the outlook on the development of the field will be presented, with the development of smartphone applications and related software helping to better enable the on-site detection of foodborne contaminants to ensure food safety and human health.
Collapse
Affiliation(s)
- Jialu Zhang
- School of Medicine, Shanghai University, Shanghai 200444, China
| | - Huinan Chen
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Kaidi Xu
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Dongmei Deng
- College of Sciences, Shanghai University, Shanghai 200444, China
| | - Qixian Zhang
- School of Materials Science and Engineering, Shanghai University, Shanghai 200436, China
- Shaoxing Institute of Technology, Shanghai University, Shaoxing 312000, China
| | - Liqiang Luo
- College of Sciences, Shanghai University, Shanghai 200444, China
| |
Collapse
|
7
|
Ebrahimi G, Samadi Pakchin P, Shamloo A, Mota A, de la Guardia M, Omidian H, Omidi Y. Label-free electrochemical microfluidic biosensors: futuristic point-of-care analytical devices for monitoring diseases. Mikrochim Acta 2022; 189:252. [PMID: 35687204 DOI: 10.1007/s00604-022-05316-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 04/20/2022] [Indexed: 10/18/2022]
Abstract
The integration of microfluidics with electrochemical analysis has resulted in the development of single miniaturized detection systems, which allows the precise control of sample volume with multianalyte detection capability in a cost- and time-effective manner. Microfluidic electrochemical sensing devices (MESDs) can potentially serve as precise sensing and monitoring systems for the detection of molecular markers in various detrimental diseases. MESDs offer several advantages, including (i) automated sample preparation and detection, (ii) low sample and reagent requirement, (iii) detection of multianalyte in a single run, (iv) multiplex analysis in a single integrated device, and (v) portability with simplicity in application and disposability. Label-free MESDs can serve an affordable real-time detection with a simple analysis in a short processing time, providing point-of-care diagnosis/detection possibilities in precision medicine, and environmental analysis. In the current review, we elaborate on label-free microfluidic biosensors, provide comprehensive insights into electrochemical detection techniques, and discuss the principles of label-free microfluidic-based sensing approaches.
Collapse
Affiliation(s)
- Ghasem Ebrahimi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran.,Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Parvin Samadi Pakchin
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Amir Shamloo
- School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Ali Mota
- Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Hossein Omidian
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA.
| |
Collapse
|