1
|
Patra P, Upadhyay TK, Alshammari N, Saeed M, Kesari KK. Alginate-Chitosan Biodegradable and Biocompatible Based Hydrogel for Breast Cancer Immunotherapy and Diagnosis: A Comprehensive Review. ACS APPLIED BIO MATERIALS 2024. [PMID: 38787337 DOI: 10.1021/acsabm.3c00984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2024]
Abstract
Breast cancer is the most common type of cancer and the second leading cause of cancer-related mortality in females. There are many side effects due to chemotherapy and traditional surgery, like fatigue, loss of appetite, skin irritation, and drug resistance to cancer cells. Immunotherapy has become a hopeful approach toward cancer treatment, generating long-lasting immune responses in malignant tumor patients. Recently, hydrogel has received more attention toward cancer therapy due to its specific characteristics, such as decreased toxicity, fewer side effects, and better biocompatibility drug delivery to the particular tumor location. Researchers globally reported various investigations on hydrogel research for tumor diagnosis. The hydrogel-based multilayer platform with controlled nanostructure has received more attention for its antitumor effect. Chitosan and alginate play a leading role in the formation of the cross-link in a hydrogel. Also, they help in the stability of the hydrogel. This review discusses the properties, preparation, biocompatibility, and bioavailability of various research and clinical approaches of the multipolymer hydrogel made of alginate and chitosan for breast cancer treatment. With a focus on cases of breast cancer and the recovery rate, there is a need to find out the role of hydrogel in drug delivery for breast cancer treatment.
Collapse
Affiliation(s)
- Pratikshya Patra
- Department of Biotechnology, Parul Institute of Applied Sciences and Animal Cell Culture and Immunobiochemistry Lab, Research and Development Cell, Parul University, Vadodara, Gujarat 391760, India
| | - Tarun Kumar Upadhyay
- Department of Biotechnology, Parul Institute of Applied Sciences and Animal Cell Culture and Immunobiochemistry Lab, Research and Development Cell, Parul University, Vadodara, Gujarat 391760, India
| | - Nawaf Alshammari
- Department of Biology, College of Science, University of Hail, Hail 53962, Saudi Arabia
| | - Mohd Saeed
- Department of Biology, College of Science, University of Hail, Hail 53962, Saudi Arabia
| | - Kavindra Kumar Kesari
- Department of Applied Physics, School of Science, Aalto University, Espoo FI-00076, Finland
- Centre of Research Impact and Outcome, Chitkara University, Rajpura 140417, Punjab, India
| |
Collapse
|
2
|
Mao Y, Wang Q, Zhang H, Li Y, Wang L. Zwitterion mediated anti-protein adsorption on polypropylene mesh to reduce inflammation for efficient hernia repair. BIOMATERIALS ADVANCES 2024; 158:213769. [PMID: 38266333 DOI: 10.1016/j.bioadv.2024.213769] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 01/03/2024] [Accepted: 01/10/2024] [Indexed: 01/26/2024]
Abstract
The effectiveness of polypropylene (PP) mesh is often compromised by severe inflammation. Engineering anti-inflammatory coatings has significant implications for PP mesh to repair unwanted hernias. Here, we presented a facile strategy to develop an anti-fouling coating consisting of zwitterionic poly(carboxybetaine methacrylate) (PCBMA), which could prohibit protein adsorption to endow PP mesh with anti-inflammatory efficacy. The incorporation of PCBMA coating had little impact on the raw features of PP mesh. While the modified mesh PCBMA-PP possessed noticeable hydrophilicity increase and surface charge reduction. The excellent lubricity and surface stability enabled PCBMA-PP to exhibit superior anti-fouling capacity, thus efficiently inhibiting the adsorption of proteins. In vivo experiments showed that incorporating the PCBMA layer could provide PP meshes with outstanding anti-inflammatory effects and tissue compatibility for repairing hernias.
Collapse
Affiliation(s)
- Ying Mao
- Key Laboratory of Textile Science and Technology of Ministry of Education and College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang District, Shanghai 201620, China; National Engineering Lab for Textile Fiber Materials & Processing Technology (Zhejiang), Zhejiang Sci-Tech University, Hangzhou 310018, China
| | - Qian Wang
- Key Laboratory of Textile Science and Technology of Ministry of Education and College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang District, Shanghai 201620, China
| | - Huiru Zhang
- Key Laboratory of Textile Science and Technology of Ministry of Education and College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang District, Shanghai 201620, China
| | - Yan Li
- Key Laboratory of Textile Science and Technology of Ministry of Education and College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang District, Shanghai 201620, China.
| | - Lu Wang
- Key Laboratory of Textile Science and Technology of Ministry of Education and College of Textiles, Donghua University, 2999 North Renmin Road, Songjiang District, Shanghai 201620, China
| |
Collapse
|
3
|
Zhao CY, Sheng KJ, Bao T, Shi T, Liu PN, Yan Y, Zheng XL. Commercial and novel anticoagulant ECMO coatings: a review. J Mater Chem B 2023. [PMID: 37183615 DOI: 10.1039/d3tb00471f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Extracorporeal membrane oxygenation (ECMO) is an invasive and last-resort treatment for circulatory and respiratory failure. Prolonged ECMO support can disrupt the coagulation and anticoagulation systems in a patient, leading to adverse consequences, such as bleeding and thrombosis. To address this problem, anticoagulation coatings have been developed for use in ECMO circuits. This article reviews commonly used commercial and novel anticoagulant coatings developed in recent years and proposes a new classification of coatings based on the current state. While commercial coatings have been used clinically for decades, this review focuses on comparing the effectiveness and stability of coatings to support clinical selections. Furthermore, novel anticoagulation coatings often involve complex mechanisms and elaborate design strategies, and this review summarises representative studies on mainstream anticoagulation coatings to provide a point of reference for future studies.
Collapse
Affiliation(s)
- Chang-Ying Zhao
- Department of Cardiovascular Surgery, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, China.
| | - Kang-Jia Sheng
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Tao Bao
- School of Pharmacy, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China
| | - Tao Shi
- Department of Cardiovascular Surgery, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, China.
| | - Pei-Nan Liu
- Department of Oncology, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710004, China
| | - Yang Yan
- Department of Cardiovascular Surgery, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, China.
| | - Xing-Long Zheng
- Department of Cardiovascular Surgery, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, China.
| |
Collapse
|
4
|
Yu H, Wang L, Zhang Z, Zhang X, Luan S, Shi H. Regulable Polyelectrolyte-Surfactant Complex for Antibacterial Biomedical Catheter Coating via a Readily Scalable Route. Adv Healthc Mater 2023; 12:e2202096. [PMID: 36285359 DOI: 10.1002/adhm.202202096] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/21/2022] [Indexed: 11/07/2022]
Abstract
Constructing multifunctional surfaces is one of the practical approaches to address catheter-related multiple complications but is generally time-consuming and substrate-dependent. Herein, a novel anti-adhesion, antibacterial, low friction, and robustness coating on medical catheters are developed via a universal and readily scalable method based on a regulable polyelectrolyte surfactant complex. The complex is rapidly assembled in one step by electrostatic and hydrophobic interactions between organosilicon quaternary ammonium surfactant (N+ Si ) and adjustable polyelectrolyte with cross-linkable, anti-adhesive, and anionic groups. The alcohol-soluble feature of the complex is conducive to the rapid formation of coatings on any medical device with arbitrary shapes via dip coating. Different from the conventional polyelectrolyte-surfactant complex coating, the regulated complex coating with nonleaching mode could be stable in harsh conditions (high concentration salt solution, organic reagents, etc.) because of the cross-linked structure while improving the biocompatibility and reducing the adhesion of various bacteria, proteins, and blood cells. The coated catheter exhibits good antibacterial infection in vitro and in vivo, owing to the synergistic effect of N+ Si and zwitterionic groups. Therefore, the rationally designed complex supplies a facile coating approach for the potential development in combating multiple complications of the medical catheter.
Collapse
Affiliation(s)
- Huan Yu
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, P. R. China.,State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| | - Lei Wang
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| | - Zhenyan Zhang
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, P. R. China.,State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| | - Xu Zhang
- State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| | - Shifang Luan
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, P. R. China.,State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| | - Hengchong Shi
- School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei, 230026, P. R. China.,State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| |
Collapse
|
5
|
Liu Y, Han Q, Li G, Lin H, Liu F, Li Q, Deng G. Anticoagulation polyvinyl chloride extracorporeal circulation catheters for heparin-free treatment. J Mater Chem B 2022; 10:8302-8314. [PMID: 36165336 DOI: 10.1039/d2tb01584f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Extracorporeal circulation (ECC) catheters have potential to be blood compatible and could be used to prevent thrombotic occlusion. Here, we produced heparin-mimicking anticoagulation PVC tubing on a large scale by synthesizing a heparin-mimicking polymer (HMP) and co-extruding. The PVC@HMP catheter was evaluated using whole human blood in vitro, which indicated it could prevent plasma protein attachment, reduce platelet adhesion and activation, and inhibit coagulation factors (XII, XI, IX, and VIII). Moreover, the anticoagulation PVC tubing was assembled into extracorporeal circulation with a New Zealand rabbit model, manifesting excellent real-time antithrombogenic properties without systemic heparin anticoagulation in vivo. The rapid recovery of coagulation factors after operation further confirmed its superiority over heparin, which would not completely inactivate the activity of those coagulation factors (XII, XI, IX and VIII). In addition, the PVC@HMP-1 catheters remain patent after being implanted in rats for 28 days without apparent inflammation and mortality complications. The anticoagulation PVC tubes could be used to construct various systemic and integrative anticlotting biomedical devices, which would dramatically reduce the introduction of heparin into blood circulation, thus preventing side effects and promoting the development of heparin-free treatment.
Collapse
Affiliation(s)
- Yang Liu
- Key Laboratory of Bio-based Polymeric Materials Technology and Application of Zhejiang Province, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, No. 1219 Zhongguan West Rd, Ningbo 315201, P. R. China. .,University of Chinese Academy of Sciences, 19 A Yuquan Rd, Shijingshan District, Beijing 100049, P. R. China
| | - Qiu Han
- Key Laboratory of Bio-based Polymeric Materials Technology and Application of Zhejiang Province, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, No. 1219 Zhongguan West Rd, Ningbo 315201, P. R. China.
| | - Guiliang Li
- Key Laboratory of Bio-based Polymeric Materials Technology and Application of Zhejiang Province, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, No. 1219 Zhongguan West Rd, Ningbo 315201, P. R. China. .,University of Chinese Academy of Sciences, 19 A Yuquan Rd, Shijingshan District, Beijing 100049, P. R. China
| | - Haibo Lin
- Key Laboratory of Bio-based Polymeric Materials Technology and Application of Zhejiang Province, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, No. 1219 Zhongguan West Rd, Ningbo 315201, P. R. China.
| | - Fu Liu
- Key Laboratory of Bio-based Polymeric Materials Technology and Application of Zhejiang Province, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences, No. 1219 Zhongguan West Rd, Ningbo 315201, P. R. China. .,University of Chinese Academy of Sciences, 19 A Yuquan Rd, Shijingshan District, Beijing 100049, P. R. China
| | - Qiang Li
- Department of Laboratory Medicine, The First Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, 310006, P. R. China
| | - Gang Deng
- The Ningbo Central Blood Station, Ningbo, 315201, P. R. China
| |
Collapse
|