Hadiuzzaman M, Mirza N, Brown SP, Ladner DA, Salehi M. Lead (Pb) deposition onto new and biofilm-laden potable water pipes. CHEMOSPHERE 2023; 342:140135. [PMID: 37690561 DOI: 10.1016/j.chemosphere.2023.140135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 09/12/2023]
Abstract
Heavy metals' interactions with plumbing materials are complicated due to the differential formation of biofilms within pipes that can modulate, transform, and/or sequester heavy metals. This research aims to elucidate the mechanistic role of biofilm presence on Lead (Pb) accumulation onto crosslinked polyethylene (PEX-A), high-density polyethylene (HDPE), and copper potable water pipes. For this purpose, biofilms were grown on new pipes for three months. Five-day Pb exposure experiments were conducted to examine the kinetics of Pb accumulation onto the new and biofilm-laden pipes. Additionally, the influence of Pb initial concentration on the rate of its accumulation onto the pipes was examined. The results revealed greater biofilm biomass on the PEX-A pipes compared to the copper and HDPE pipes. More negative zeta potential was found for the biofilm-laden plastic pipes compared to the new plastic pipes. After five days of Pb exposure under stagnant conditions, the biofilm-laden PEX-A (980 μg m-2) and HDPE (1170 μg m-2) pipes accumulated more than three times the Pb surface loading compared to the new PEX-A (265 μg m-2) and HDPE pipes (329 μg m-2), respectively. However, under flow conditions, Pb accumulation on biofilm-laden plastic pipes was lower than on the new pipes. Moreover, with increasing the initial Pb concentration, greater rates of Pb surface accumulation were found for the biofilm-laden pipes compared to the new pipes under stagnant conditions. First-order kinetics model best described the Pb accumulation onto both new and biofilm-laden water pipes under both stagnant and flow conditions.
Collapse
Affiliation(s)
- Md Hadiuzzaman
- Department of Civil Engineering, The University of Memphis, Memphis, TN, USA
| | - Nahreen Mirza
- Department of Biological Sciences, The University of Memphis, Memphis, TN, USA
| | - Shawn P Brown
- Department of Biological Sciences, The University of Memphis, Memphis, TN, USA
| | - David A Ladner
- Department of Environmental Engineering and Earth Sciences, Clemson University, Anderson, SC, USA
| | - Maryam Salehi
- Department of Civil and Environmental Engineering, University of Missouri, Columbia, MO, USA.
| |
Collapse
|
2
|
Liu Y, Gao J, Zhu Q, Zhou X, Chu W, Huang J, Liu C, Yang B, Yang M. Zerovalent Iron/Cu Combined Degradation of Halogenated Disinfection Byproducts and Quantitative Structure-Activity Relationship Modeling. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:11241-11250. [PMID: 37461144 DOI: 10.1021/acs.est.3c01960] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Previous studies have reported that zerovalent iron (ZVI) can reduce several aliphatic groups of disinfection byproducts (DBPs) (e.g., haloacetic acids and haloacetamides) effectively, and the removal efficiency can be significantly improved by metallic copper. Information regarding ZVI/Cu combined degradation of different types of halogenated DBPs can help understand the fate of overall DBPs in drinking water distribution and storage systems consisting of unlined cast iron/copper pipes and related potential control strategies. In this study, we found that, besides aliphatic DBPs, many groups of new emerging aromatic DBPs formed in chlorinated and chloraminated drinking water can be effectively degraded by ZVI/Cu; meanwhile, total organic halogen and total ion intensity were reduced significantly after treatment. Moreover, a robust quantitative structure-activity relationship model was developed and validated based on the ZVI/Cu combined degradation rate constants of 14 typical aromatic DBPs; it can predict the degradation rate constants of other aromatic DBPs for screening and comparative purposes, and the optimized descriptors indicate that DBPs possessing a lower value of the lowest unoccupied molecular orbital energy and a higher value of dipole moment tend to present higher degradation rate constants. In addition, toxicity data of 47 DBPs (belonging to 18 groups) were predicted by two previously established toxicity models, demonstrating that, although most DBPs exhibit higher toxicity than their dehalogenated products, some DBPs show lower toxicity than their lowly halogenated analogs.
Collapse
Affiliation(s)
- Yan Liu
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Jianfa Gao
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Qingyao Zhu
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Xi Zhou
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Wenhai Chu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Jingxiong Huang
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Changkun Liu
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Bo Yang
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| | - Mengting Yang
- College of Chemistry and Environmental Engineering, Shenzhen University, Shenzhen 518060, China
| |
Collapse
|
3
|
Vanderzwalmen M, Sánchez Lacalle D, Tamilselvan P, McNeill J, Delieuvin D, Behlouli K, Hursthouse A, McLellan I, Alexander ME, Henriquez FL, Snellgrove D, Sloman KA. The Effect of Substrate on Water Quality in Ornamental Fish Tanks. Animals (Basel) 2022; 12:ani12192679. [PMID: 36230419 PMCID: PMC9558538 DOI: 10.3390/ani12192679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 09/23/2022] [Accepted: 09/23/2022] [Indexed: 11/05/2022] Open
Abstract
Simple Summary Fish kept as pets are almost always held in tanks with substrate such as gravel or sand on the bottom of the tank. This may be added as a form of enrichment to encourage natural fish behaviours, or for aesthetic reasons. However, substrate can also harbour elevated levels of waste products and unwanted bacteria; therefore, whether the use of substrate in home aquaria is advantageous or disadvantageous has not been fully considered. Here, we investigated whether there was a difference in water quality in home aquaria that contained either no substrate (bare tanks), plastic plants as enrichment but no substrate, sand or gravel substrate. Water quality (e.g., temperature, oxygen, pH and ammonia) and the presence of bacteria were measured over a 7-week period. As water quality can also vary with the season, the study was repeated at different times of the year. Addition of both gravel and sand substrate resulted in increased pH and the waste products ammonia and nitrate. Substrate was also associated with a greater presence of bacteria. In conclusion, the use of substrate affected water quality, with further research needed on the use of substrate in home aquaria. Abstract Almost all home aquaria contain substrate, either as intentional enrichment or for aesthetic purposes. For fishes, benefits of structural enrichment have been well considered, particularly in research and aquaculture settings. However, our understanding of the impacts of tank substrate as enrichment is limited. While substrate can induce foraging in some species, a major drawback is the potential of substrate to harbour elevated levels of waste and pathogenic bacteria. Here, we considered whether substrate as a form of environmental enrichment significantly altered water quality and bacterial presence in home aquaria. Water quality (temperature, oxygen, pH, TAN, unionised ammonia, nitrate, Ca2+, Na+, Mg2+ and K+) and bacterial presence (Pseudomonas spp.) were measured over two seven-week periods in stand-alone, tropical, freshwater tanks that simulated home aquaria. The following four enrichment conditions were considered: bare tanks, plastic plants, gravel substrate or sand substrate. The addition of both gravel and sand resulted in increased pH, concentrations of total ammonia nitrogen and nitrate. Substrate was also associated with a greater Pseudomonas presence. Decreased pH alongside an increased concentration of ions were also observed depending on the time of year. In conclusion, enrichment type affected the water quality of home aquaria, with further research needed on the role of the tank biome in fish welfare.
Collapse
Affiliation(s)
- Myriam Vanderzwalmen
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Daniel Sánchez Lacalle
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Priyadarshini Tamilselvan
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Jason McNeill
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Dorine Delieuvin
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Khadidja Behlouli
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Andrew Hursthouse
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Iain McLellan
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Paisley Campus, Paisley PA1 2BE, UK
| | - Mhairi E. Alexander
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Lanarkshire Campus, Glasgow G72 0LH, UK
| | - Fiona L. Henriquez
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Lanarkshire Campus, Glasgow G72 0LH, UK
| | - Donna Snellgrove
- WALTHAM Petcare Science Institute, Freeby Lane, Waltham-on-the-Wolds, Leicestershire LE14 4RT, UK
| | - Katherine A. Sloman
- Institute of Biomedical and Environmental Health Research, University of the West of Scotland, Lanarkshire Campus, Glasgow G72 0LH, UK
- Correspondence:
| |
Collapse
|
4
|
Tang M, Harmon S, Nadagouda MN, Lytle DA. Quartz Crystal Microbalance with Dissipation: A New Approach of Examining Corrosion of New Copper Surfaces in Drinking Water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:10.1021/acs.est.1c02220. [PMID: 34319119 PMCID: PMC8795246 DOI: 10.1021/acs.est.1c02220] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Corrosion of copper material in drinking water systems causes public health concerns and plumbing failures. This study investigated the early corrosion of new copper surfaces in situ using a novel technique: quartz crystal microbalance with dissipation (QCMD). The QCMD results showed that increasing the water pH from 6.5 to 9.0 and the addition of 6 mg/L orthophosphate at pH 6.5 and 9.0 slowed down the copper surface mass changes as indicated by the reduced changes in frequency (Δf5) at 51-89% and total copper release at 29-72%. The water pH 9.0 without orthophosphate was the most likely to induce localized corrosion relative to other conditions at pH 6.5 and pH 9.0 with orthophosphate. Based on the changes in dissipation values (ΔD5) from QCMD and the morphology, microstructure, and composition of the deposited copper corrosion byproducts, digital microscopy, field-emission scanning electron microscopy with energy dispersive spectroscopy, and X-ray photoelectron spectrometry analyses confirmed that the pH and orthophosphate inhibited copper corrosion with different mechanisms. QCMD provided sensitive, rapid, and continuous responses to mass and surface changes and can be useful for evaluating early water corrosivity to new copper.
Collapse
Affiliation(s)
- Min Tang
- ORISE Postdoctoral Fellow at U.S. Environmental Protection Agency, ORD, CESER, WID, DWMB, 26 W. Martin Luther King Drive, Cincinnati, Ohio 45268, United States
| | - Stephen Harmon
- U.S. Environmental Protection Agency, ORD, CESER, WID, DWMB, 26 W. Martin Luther King Drive, Cincinnati, Ohio 45268, United States
| | - Mallikarjuna N Nadagouda
- U.S. Environmental Protection Agency, ORD, CESER, WID, DWMB, 26 W. Martin Luther King Drive, Cincinnati, Ohio 45268, United States
| | - Darren A Lytle
- U.S. Environmental Protection Agency, ORD, CESER, WID, DWMB, 26 W. Martin Luther King Drive, Cincinnati, Ohio 45268, United States
| |
Collapse
|
5
|
Vargas IT, Fischer DA, Alsina MA, Pavissich JP, Pastén PA, Pizarro GE. Copper Corrosion and Biocorrosion Events in Premise Plumbing. MATERIALS 2017; 10:ma10091036. [PMID: 28872628 PMCID: PMC5615691 DOI: 10.3390/ma10091036] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 08/20/2017] [Accepted: 08/30/2017] [Indexed: 11/22/2022]
Abstract
Corrosion of copper pipes may release high amounts of copper into the water, exceeding the maximum concentration of copper for drinking water standards. Typically, the events with the highest release of copper into drinking water are related to the presence of biofilms. This article reviews this phenomenon, focusing on copper ingestion and its health impacts, the physicochemical mechanisms and the microbial involvement on copper release, the techniques used to describe and understand this phenomenon, and the hydrodynamic effects. A conceptual model is proposed and the mathematical models are reviewed.
Collapse
Affiliation(s)
- Ignacio T Vargas
- Departamento de Ingeniería Hidráulica y Ambiental, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
- CEDEUS, Centro de Desarrollo Urbano Sustentable, Santiago 7820436, Chile.
| | - Diego A Fischer
- Departamento de Ingeniería Hidráulica y Ambiental, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
| | - Marco A Alsina
- Departamento de Ingeniería Hidráulica y Ambiental, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
| | - Juan P Pavissich
- Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Santiago 7941169, Chile.
| | - Pablo A Pastén
- Departamento de Ingeniería Hidráulica y Ambiental, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
- CEDEUS, Centro de Desarrollo Urbano Sustentable, Santiago 7820436, Chile.
| | - Gonzalo E Pizarro
- Departamento de Ingeniería Hidráulica y Ambiental, Pontificia Universidad Católica de Chile, Santiago 7820436, Chile.
- CEDEUS, Centro de Desarrollo Urbano Sustentable, Santiago 7820436, Chile.
| |
Collapse
|
6
|
Chu W, Li X, Bond T, Gao N, Bin X, Wang Q, Ding S. Copper increases reductive dehalogenation of haloacetamides by zero-valent iron in drinking water: Reduction efficiency and integrated toxicity risk. WATER RESEARCH 2016; 107:141-150. [PMID: 27837731 DOI: 10.1016/j.watres.2016.10.047] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 10/16/2016] [Accepted: 10/19/2016] [Indexed: 06/06/2023]
Abstract
The haloacetamides (HAcAms), an emerging class of nitrogen-containing disinfection byproducts (N-DBPs), are highly cytotoxic and genotoxic, and typically occur in treated drinking waters at low μg/L concentrations. Since many drinking distribution and storage systems contain unlined cast iron and copper pipes, reactions of HAcAms with zero-valent iron (ZVI) and metallic copper (Cu) may play a role in determining their fate. Moreover, ZVI and/or Cu are potentially effective HAcAm treatment technologies in drinking water supply and storage systems. This study reports that ZVI alone reduces trichloroacetamide (TCAcAm) to sequentially form dichloroacetamide (DCAcAm) and then monochloroacetamide (MCAcAm), whereas Cu alone does not impact HAcAm concentrations. The addition of Cu to ZVI significantly improved the removal of HAcAms, relative to ZVI alone. TCAcAm and their reduction products (DCAcAm and MCAcAm) were all decreased to below detection limits at a molar ratio of ZVI/Cu of 1:1 after 24 h reaction (ZVI/TCAcAm = 0.18 M/5.30 μM). TCAcAm reduction increased with the decreasing pH from 8.0 to 5.0, but values from an integrated toxic risk assessment were minimised at pH 7.0, due to limited removal MCAcAm under weak acid conditions (pH = 5.0 and 6.0). Higher temperatures (40 °C) promoted the reductive dehalogenation of HAcAms. Bromine was preferentially removed over chlorine, thus brominated HAcAms were more easily reduced than chlorinated HAcAms by ZVI/Cu. Although tribromoacetamide was more easily reduced than TCAcAm during ZVI/Cu reduction, treatment of tribromoacetamide resulted in a higher integrated toxicity risk than TCAcAm, due to the formation of monobromoacetamide (MBAcAm).
Collapse
Affiliation(s)
- Wenhai Chu
- State Key Laboratory of Pollution Control and Resources Reuse, Institute of Disinfection By-product Control in Water Treatment, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China.
| | - Xin Li
- State Key Laboratory of Pollution Control and Resources Reuse, Institute of Disinfection By-product Control in Water Treatment, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Tom Bond
- Department of Civil and Environmental Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Naiyun Gao
- State Key Laboratory of Pollution Control and Resources Reuse, Institute of Disinfection By-product Control in Water Treatment, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Xu Bin
- State Key Laboratory of Pollution Control and Resources Reuse, Institute of Disinfection By-product Control in Water Treatment, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Qiongfang Wang
- State Key Laboratory of Pollution Control and Resources Reuse, Institute of Disinfection By-product Control in Water Treatment, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Shunke Ding
- State Key Laboratory of Pollution Control and Resources Reuse, Institute of Disinfection By-product Control in Water Treatment, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| |
Collapse
|
7
|
Bédard E, Prévost M, Déziel E. Pseudomonas aeruginosa in premise plumbing of large buildings. Microbiologyopen 2016; 5:937-956. [PMID: 27353357 PMCID: PMC5221438 DOI: 10.1002/mbo3.391] [Citation(s) in RCA: 83] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Revised: 06/01/2016] [Accepted: 06/06/2016] [Indexed: 12/27/2022] Open
Abstract
Pseudomonas aeruginosa is an opportunistic bacterial pathogen that is widely occurring in the environment and is recognized for its capacity to form or join biofilms. The present review consolidates current knowledge on P. aeruginosa ecology and its implication in healthcare facilities premise plumbing. The adaptability of P. aeruginosa and its capacity to integrate the biofilm from the faucet and the drain highlight the role premise plumbing devices can play in promoting growth and persistence. A meta‐analysis of P. aeruginosa prevalence in faucets (manual and electronic) and drains reveals the large variation in device positivity reported and suggest the high variability in the sampling approach and context as the main reason for this variation. The effects of the operating conditions that prevail within water distribution systems (disinfection, temperature, and hydraulic regime) on the persistence of P. aeruginosa are summarized. As a result from the review, recommendations for proactive control measures of water contamination by P. aeruginosa are presented. A better understanding of the ecology of P. aeruginosa and key influencing factors in premise plumbing are essential to identify culprit areas and implement effective control measures.
Collapse
Affiliation(s)
- Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada.,INRS-Institut Armand-Frappier, Laval, QC, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| | - Eric Déziel
- INRS-Institut Armand-Frappier, Laval, QC, Canada
| |
Collapse
|
8
|
Release of Metals from Different Sections of Domestic Drinking Water Installations. ACTA ACUST UNITED AC 2014. [DOI: 10.1007/s12403-014-0140-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
9
|
Bédard E, Charron D, Lalancette C, Déziel E, Prévost M. Recovery of Pseudomonas aeruginosa culturability following copper- and chlorine-induced stress. FEMS Microbiol Lett 2014; 356:226-34. [PMID: 24893953 DOI: 10.1111/1574-6968.12494] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 05/27/2014] [Accepted: 05/30/2014] [Indexed: 11/29/2022] Open
Abstract
This study investigated how quickly cells of the opportunistic pathogen Pseudomonas aeruginosa recover culturability after exposure to two of the most common environmental stressors present in drinking water, free chlorine and copper ions. Viable but nonculturable (VBNC) P. aeruginosa undetected by direct culturing following exposure to free chlorine or copper ions can survive in drinking water systems, with potential to recover, multiply, and regain infectivity. Cells were exposed to copper sulfate (0.25 mg Cu(2+) L(-1) ) or free chlorine (initial dose of 2 mg Cl2 L(-1) ) for 24 h. Despite total loss of culturability and a reduction in viability from 1.2 × 10(7) to 4 × 10(3) cells mL(-1) (3.5 log), cells exposed to chlorine recovered viability quickly after the depletion of free chlorine, while culturability was recovered within 24 h. Copper ions did not depress viability, but reduced culturability from 3 × 10(7) to 2.3 × 10(2) cells mL(-1) (5.1 log); VBNC cells regained culturability immediately after copper ion chelation. A comparison between direct culturing and Pseudalert, a specific enzyme-based assay, was performed. Both detection methods were well correlated in the range of 10(2) -10(10) cells L(-1) . However, correlations between the methods declined after exposure to copper ions.
Collapse
Affiliation(s)
- Emilie Bédard
- Department of Civil Engineering, Polytechnique Montreal, Montreal, QC, Canada; INRS-Institut Armand-Frappier, Laval, QC, Canada
| | | | | | | | | |
Collapse
|
10
|
Waines PL, Moate R, Moody AJ, Allen M, Bradley G. The effect of material choice on biofilm formation in a model warm water distribution system. BIOFOULING 2011; 27:1161-1174. [PMID: 22117115 DOI: 10.1080/08927014.2011.636807] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Water distribution systems (WDS) are composed of a variety of materials and may harbour potential pathogens within surface-attached microbial biofilms. Biofilm formation on four plumbing materials, viz. copper, stainless steel 316 (SS316), ethylene propylene diene monomer (EPDM) and cross-linked polyethylene (PEX), was investigated using scanning electron microscope (SEM)/confocal microscopy, ATP-/culture-based analysis, and molecular analysis. Material 'inserts' were incorporated into a mains water fed, model WDS. All materials supported biofilm growth to various degrees. After 84 days, copper and SS316 showed no significant overall differences in terms of the level of biofilm formation observed, whilst PEX supported a significantly higher level of biofilm. EPDM exhibited gross contamination by a complex, multispecies biofilm, at a level significantly higher than was observed on the other materials, regardless of the analytical method used. PCR-DGGE analysis showed clear differences in the composition of the biofilm community on all materials after 84 days. The primary conclusion of this study has been to identify EPDM as a potentially unsuitable material for use as a major component in WDS.
Collapse
Affiliation(s)
- Paul L Waines
- School of Biomedical and Biological Sciences, Plymouth University, Drake Circus, Plymouth, Devon, PL4 8AA, UK.
| | | | | | | | | |
Collapse
|
11
|
van den Akker B, Holmes M, Cromar N, Fallowfield H. Application of high rate nitrifying trickling filters for potable water treatment. WATER RESEARCH 2008; 42:4514-4524. [PMID: 18752823 DOI: 10.1016/j.watres.2008.07.038] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2008] [Revised: 07/27/2008] [Accepted: 07/30/2008] [Indexed: 05/26/2023]
Abstract
The interference of ammonia with chlorination is a prevalent problem encountered by water treatment plants located throughout South East Asia. The efficacy of high rate, plastic-packed trickling filters as a pre-treatment process to remove low concentrations of ammonia from polluted surface water was investigated. This paper presents the findings from a series of pilot experiments, which were designed to investigate the effect of specific conditions-namely low ammonia feed concentrations (0.5-5.0 mg NH(4)-NL(-1)), variations in hydraulic surface load (72.5-145 m(3)m(-2)d(-1)) and high suspended solid loads (51+/-25 mgL(-1))-on filter nitrifying capacity. The distribution of nitrification activity throughout a trickling filter bed was also characterised. Results confirmed that high hydraulic rate trickling filters were able to operate successfully, under ammonia-N concentrations some 10- to 50-fold lower and at hydraulic loading rates 30-100 times greater than those of conventional wastewater applications. Mass transport limitations posed by low ammonia-N concentrations on overall filter performance were insignificant, where apparent nitrification rates (0.4-1.6 g NH(4)-Nm(-2)d(-1)), equivalent to that of wastewater filters were recorded. High inert suspended solid loadings had no adverse effect on nitrification. Results imply that implementation of high rate trickling filters at the front-end of a water treatment train would reduce the ammonia-related chlorine demand, thereby offering significant cost savings.
Collapse
Affiliation(s)
- Ben van den Akker
- Department of Environmental Health and Flinders Research Centre for Coastal and Catchment Environments, Flinders University, Bedford Park, South Australia, Australia.
| | | | | | | |
Collapse
|
12
|
|
13
|
Mustonen SM, Tissari S, Huikko L, Kolehmainen M, Lehtola MJ, Hirvonen A. Evaluating online data of water quality changes in a pilot drinking water distribution system with multivariate data exploration methods. WATER RESEARCH 2008; 42:2421-2430. [PMID: 18295299 DOI: 10.1016/j.watres.2008.01.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2007] [Revised: 11/25/2007] [Accepted: 01/17/2008] [Indexed: 05/25/2023]
Abstract
The distribution of drinking water generates soft deposits and biofilms in the pipelines of distribution systems. Disturbances in water distribution can detach these deposits and biofilms and thus deteriorate the water quality. We studied the effects of simulated pressure shocks on the water quality with online analysers. The study was conducted with copper and composite plastic pipelines in a pilot distribution system. The online data gathered during the study was evaluated with Self-Organising Map (SOM) and Sammon's mapping, which are useful methods in exploring large amounts of multivariate data. The objective was to test the usefulness of these methods in pinpointing the abnormal water quality changes in the online data. The pressure shocks increased temporarily the number of particles, turbidity and electrical conductivity. SOM and Sammon's mapping were able to separate these situations from the normal data and thus make those visible. Therefore these methods make it possible to detect abrupt changes in water quality and thus to react rapidly to any disturbances in the system. These methods are useful in developing alert systems and predictive applications connected to online monitoring.
Collapse
Affiliation(s)
- Satu M Mustonen
- Department of Environmental Science, University of Kuopio, P.O. Box 1627, FI-70211 Kuopio, Finland
| | | | | | | | | | | |
Collapse
|
14
|
Lehtola MJ, Miettinen IT, Lampola T, Hirvonen A, Vartiainen T, Martikainen PJ. Pipeline materials modify the effectiveness of disinfectants in drinking water distribution systems. WATER RESEARCH 2005; 39:1962-71. [PMID: 15869778 DOI: 10.1016/j.watres.2005.03.009] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2004] [Revised: 12/29/2004] [Indexed: 05/02/2023]
Abstract
We studied how pipe material can modify the effectiveness of UV- and chlorine disinfection in drinking water and biofilms. This study was done with two pipe materials: copper and composite plastic (polyethylene, PE) in a pilot scale water distribution network. UV-disinfection decreased viable bacterial numbers in the pilot waterworks and outlet water of pipes on average by 79%, but in biofilms its disinfecting effect was minor. Chlorine decreased effectively the microbial numbers in water and biofilms of PE pipes. In outlet water from copper pipes, the effect of chlorination was weaker; microbial numbers increased back to the level before chlorination within a few days. In the biofilms present in the copper pipes, chlorine decreased microbial numbers only in front of the pipeline. One reason for weaker efficiency of chlorine in copper pipes was that its concentration declined more rapidly in the copper pipes than in the PE pipes. These results means that copper pipes may require a higher chlorine dosage than plastic pipes to achieve effective disinfection of the pipes.
Collapse
Affiliation(s)
- Markku J Lehtola
- Laboratory of Environmental Microbiology, Department of Environmental Health, National Public Health Institute, P.O. Box 95, FIN-70701, Kuopio, Finland.
| | | | | | | | | | | |
Collapse
|
15
|
Abstract
AIMS To investigate the influence of micro-organisms associated with copper corrosion on 'blue water' corrosion in drinking water. METHODS AND RESULTS Laboratory rigs comprising of polycarbonate containers attached to annealed copper plumbing tubes were filled with Melbourne drinking water and sterilized by autoclaving. The copper tubes were inoculated with sterile or nonsterile extracts obtained from corroding copper and allowed to stand for 7 days. The extracts were drained and the tubes flushed and filled with sterile water from the rig. The water within the tubes was removed weekly for analysis and the tubes were refilled with freshly aerated water. The tube water sampled was analysed for pH, total copper and the presence of micro-organisms. Sterile rigs and rigs containing nonsterile water, both without tube inoculums, were used as controls. The results demonstrated that tubes inoculated with nonsterile corrosion extracts showed statistically higher copper release compared with the other rigs. Copper release as blue water was only observed after a lag period of 9 weeks. The internal surfaces of tubes releasing copper showed significant amounts of corrosion products and the presence of biofilm. Bacteria isolated from the corroding tubes included Acidovorax spp. and Sphingomonas sp. CONCLUSIONS The results demonstrate a microbial role in blue water, as corrosion was induced in new copper tubes by exposure to nonsterile copper corrosion products. SIGNIFICANCE AND IMPACT OF THE STUDY The potential for micro-organisms present in corrosion products to initiate blue water corrosion presents significant implications for the management of corrosion in distribution systems.
Collapse
Affiliation(s)
- M M Critchley
- CSIRO Manufacturing and Infrastructure Technology, Clayton South, Victoria, Australia.
| | | | | |
Collapse
|
16
|
Lehtola MJ, Miettinen IT, Keinänen MM, Kekki TK, Laine O, Hirvonen A, Vartiainen T, Martikainen PJ. Microbiology, chemistry and biofilm development in a pilot drinking water distribution system with copper and plastic pipes. WATER RESEARCH 2004; 38:3769-79. [PMID: 15350429 DOI: 10.1016/j.watres.2004.06.024] [Citation(s) in RCA: 140] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2003] [Revised: 05/17/2004] [Accepted: 06/30/2004] [Indexed: 05/08/2023]
Abstract
We studied the changes in water quality and formation of biofilms occurring in a pilot-scale water distribution system with two generally used pipe materials: copper and plastic (polyethylene, PE). The formation of biofilms with time was analysed as the number of total bacteria, heterotrophic plate counts and the concentration of ATP in biofilms. At the end of the experiment (after 308 days), microbial community structure, viable biomass and gram-negative bacterial biomass were analysed via lipid biomarkers (phospholipid fatty acids and lipopolysaccharide 3-hydroxy fatty acids), and the numbers of virus-like particles and total bacteria were enumerated by SYBR Green I staining. The formation of biofilm was slower in copper pipes than in the PE pipes, but after 200 days there was no difference in microbial numbers between the pipe materials. Copper ion led to lower microbial numbers in water during the first 200 days, but thereafter there were no differences between the two pipe materials. The number of virus-like particles was lower in biofilms and in outlet water from the copper pipes than PE pipes. Pipe material influenced also the microbial and gram-negative bacterial community structure in biofilms and water.
Collapse
Affiliation(s)
- Markku J Lehtola
- Laboratory of Environmental Microbiology, National Public Health Institute, P.O. Box 95, FIN-70701 Kuopio, Finland.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Walker JT, Bradshaw DJ, Fulford MR, Marsh PD. Microbiological evaluation of a range of disinfectant products to control mixed-species biofilm contamination in a laboratory model of a dental unit water system. Appl Environ Microbiol 2003; 69:3327-32. [PMID: 12788733 PMCID: PMC161510 DOI: 10.1128/aem.69.6.3327-3332.2003] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2002] [Accepted: 03/07/2003] [Indexed: 11/20/2022] Open
Abstract
Dental unit water system (DUWS) tubing harbors complex multispecies biofilms that are responsible for high microbial levels at the distal outlet. The aim of this study was to use an established biofilm laboratory model to simulate biofouling of DUWS to evaluate practical, cost-effective, and evidence-based methods of microbial decontamination. Reproducible biofilms were developed in the model over 14 days; decontamination was assessed using total viable counts (TVC) and microscopic-image analysis techniques to view the inner surface of tubing. Flushing did not reduce the biofilm coverage or TVC. Combizyme and ozone did not completely eliminate the viable bacteria (70 and 65% reduction in biofilm TVC, respectively), nor did they remove the biofilm (45 and 57% reduction in biofilm coverage, respectively). Chlorhexidine and Bio2000 (active agent: ethanol and chlorhexidine), Tegodor and Gigasept Rapid (aldehyde based), and Grotanol (hydroxide based) completely eliminated the TVC but did not completely remove biofilm (31, 53 33, 34, and 64.9% reduction of biofilm coverage, respectively). Other products including Grotanol Flussig (phenol based), Betadine (povidone-iodine based), Alpron (chlorite based), and the hydroxide-containing products Sporklenz, Sterilex Ultra, Dialox, Sterilox, Sanosil, Oxigenal, and Grotanat Bohrerbad resulted in a 100% reduction in the biofilm TVC and a >95% reduction in biofilm coverage. The study demonstrated that while many disinfectants achieve a sufficient reduction in TVC they may not necessarily remove unwanted biofilm from the tubing surfaces as tested in this laboratory-controlled biofilm model.
Collapse
Affiliation(s)
- J T Walker
- Health Protection Agency, Porton Down, Salisbury SP4 0JG, United Kingdom.
| | | | | | | |
Collapse
|
18
|
Critchley MM, Cromar NJ, McClure NC, Fallowfield HJ. The influence of the chemical composition of drinking water on cuprosolvency by biofilm bacteria. J Appl Microbiol 2003; 94:501-7. [PMID: 12588559 DOI: 10.1046/j.1365-2672.2003.01857.x] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
AIMS This study investigated the influence of water chemistry on copper solvation (cuprosolvency) by pure culture biofilms of heterotrophic bacteria isolated from copper plumbing. METHODS AND RESULTS Heterotrophic bacteria isolated from copper plumbing biofilms including Acidovorax delafieldii, Flavobacterium sp., Corynebacterium sp., Pseudomonas sp. and Stenotrophomonas maltophilia were used in laboratory coupon experiments to assess their potential for cuprosolvency. Sterile copper coupons were exposed to pure cultures of bacteria to allow biofilm formation and suspended in drinking waters with different chemical compositions. Sterile coupons not exposed to bacteria were used as controls. After 5 days of incubation, copper release and biofilm accumulation was quantified. The results demonstrated that cuprosolvency in the control experiments was influenced by water pH, total organic carbon (TOC) and conductivity. Cuprosolvency in the presence of biofilms correlated with the chemical composition of the water supplies particularly pH, Langeliers Index, chloride, alkalinity, TOC and soluble phosphate concentrations. CONCLUSIONS The results suggest water quality may influence cuprosolvency by biofilms present within copper plumbing pipes. SIGNIFICANCE AND IMPACT OF THE STUDY The potential for water chemistry to influence cuprosolvency by biofilms may contribute to the sporadic nature of copper corrosion problems in distribution systems.
Collapse
Affiliation(s)
- M M Critchley
- Department of Environmental Health, Flinders University, Adelaide, South Australia
| | | | | | | |
Collapse
|