1
|
Shah Syed AR, Akram A, Azam MS, Ansari AI, Muzammil MA, Ahad Syed A, Ahmed S, Zakir SJ. Dual-chamber versus single chamber pacemakers, a systemic review and meta-analysis on sick sinus syndrome and atrioventricular block patients. Heliyon 2024; 10:e23877. [PMID: 38234924 PMCID: PMC10792191 DOI: 10.1016/j.heliyon.2023.e23877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 12/10/2023] [Accepted: 12/14/2023] [Indexed: 01/19/2024] Open
Abstract
Aims The atrioventricular block (AVB) is a conduction system problem that results from the impairment in the transmission of an impulse from the atria to the ventricle, the disease has many etiologies. This article aimed to evaluate the efficacy and safety of dual and single-chamber pacemakers in patients with SSS and AVB. Methods An electronic search of PubMed (Medline), EMBASE, and Google Scholar was performed from 2000 till August 15th, 2022. Retrieved articles were exported to Endnote Reference Library Software, where duplicate studies were removed from the list, and only articles meeting the eligibility criteria of this study were selected. RevMan 5.4 and STATA 16 software were used for the analysis. The modified Cochrane Collaboration's risk of bias and New-castle Ottawa scale were used for quality assessment of RCTs and observational studies respectively. Results This study is composed of 8953 patients with sick-sinus syndrome and atrioventricular block. A total of thirteen outcomes are included in this meta-analysis, out of which atrial fibrillation significantly favored dual chamber [OR = 1.29; 95 % CI = 1.05-1.59; P = 0.01 I2 = 29 %] and overall complications [OR = 0.48; 95 % CI = 0.29-0.77; p = 0.03 I2 = 0 %] and pneumothorax [OR = 0.31; 95 % CI = 0.10-0.93; p = 0.04, I2 = 0 %] were satisfied by single-chamber pacing. Conclusion This study concluded that neither single-chamber nor dual-chamber pacemakers are superior to each other, but they are unique in their own ways as the results of this study manifest remarkable reduction in atrial fibrillation rates and pneumothorax using dual-chamber and single-chamber pacemakers respectively.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Shaheer Ahmed
- Dow University of Health Science (Medicine), Pakistan
| | | |
Collapse
|
2
|
Senaratne J, Herath TT, Beaudette D, Irwin M, Gulamhusein S, Senaratne MP. Safety and efficacy of AAIR pacing in selected patients with sick sinus syndrome. Medicine (Baltimore) 2018; 97:e12833. [PMID: 30334983 PMCID: PMC6211929 DOI: 10.1097/md.0000000000012833] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND The DANPACE study suggested implanting dual-pacing dual-sensing dual-response rate-adaptive (DDDR) pacemakers in patients with sick sinus syndrome, even though 90.7% of their atrial-pacing atrial-sensing inhibited-response rate-adaptive (AAIR) group did not require upgrade. Most centers implant DDDR pacemakers due to risk of future atrioventricular (AV) block. Given that AAIR pacemakers are less expensive, have one less lead with potentially one less point of complication, we question whether DDDR pacemakers are superior to AAIR pacemakers. We aim to describe long-term outcomes of AAIR implants. METHODS Patients presenting to the Grey Nuns Hospital in Edmonton, Canada from 1990 to 2012 with sick sinus syndrome without AV block had AAIR pacemakers implanted. Outcomes that were measured over the follow-up time included need for ventricular lead reoperation, incidence of AV block and incidence of sudden cardiac death from AV block. RESULTS During this period, 330 patients presented with sick sinus syndrome. Eighty-seven (26.4%) patients met criteria for and received AAIR pacemakers. Seventy-eight (91.8%) did not require upgrade over mean follow-up of 10.6 ± 0.6 years. Amongst this group, 31 patients (39.7%) were alive, whereas 47 (60.3%) were deceased at end of follow-up due to other comorbidities. No sudden deaths were attributable to AV block. Only 7 patients (8.2%) required ventricular lead reoperation: 2 (2.4%) presented urgently with symptomatic AV block; 3 (3.5%) had atrial fibrillation requiring beta-blockade; 1 (1.2%) had atrial lead dislodgment; and 1 (1.2%) was electively upgraded at battery end-of-life. CONCLUSIONS This study looks at safety of AAIR pacemakers with only 2.4% of patients developing AV block requiring urgent upgrade. Approximately 91.8% of patients remained with their original AAIR pacemakers (mean follow-up 10.6 vs 5.4 years in DANPACE). Our findings are similar to the DANPACE study but our conclusions are different as we believe AAIR pacing should be considered for selected patients with sick sinus syndrome without AV block.
Collapse
Affiliation(s)
| | | | - Diane Beaudette
- Division of Cardiology, Grey Nuns Community Hospital, Edmonton, Alberta, Canada
| | - Marleen Irwin
- Division of Cardiology, Grey Nuns Community Hospital, Edmonton, Alberta, Canada
| | - Sajad Gulamhusein
- Division of Cardiology, Grey Nuns Community Hospital, Edmonton, Alberta, Canada
| | | |
Collapse
|
3
|
Edwards SJ, Karner C, Trevor N, Wakefield V, Salih F. Dual-chamber pacemakers for treating symptomatic bradycardia due to sick sinus syndrome without atrioventricular block: a systematic review and economic evaluation. Health Technol Assess 2016; 19:1-210. [PMID: 26293406 DOI: 10.3310/hta19650] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND Bradycardia [resting heart rate below 60 beats per minute (b.p.m.)] can be caused by conditions affecting the natural pacemakers of the heart, such as sick sinus syndrome (SSS) and atrioventricular (AV) blocks. People suffering from bradycardia may present with palpitations, exercise intolerance and fainting. The only effective treatment for patients suffering from symptomatic bradycardia is implantation of a permanent pacemaker. OBJECTIVE To appraise the clinical effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber atrial pacemakers for treating symptomatic bradycardia in people with SSS and no evidence of AV block. DATA SOURCES All databases (MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Health Technology Assessment database, NHS Economic Evaluations Database) were searched from inception to June 2014. METHODS A systematic review of the clinical and economic literature was carried out in accordance with the general principles published by the Centre for Reviews and Dissemination. Randomised controlled trials (RCTs) evaluating dual-chamber and single-chamber atrial pacemakers and economic evaluations were included. Pairwise meta-analysis was carried out. A de novo economic model was developed. RESULTS Of 493 references, six RCTs were included in the review. The results were predominantly influenced by the largest trial DANPACE. Dual-chamber pacing was associated with a statistically significant reduction in reoperation [odds ratio (OR) 0.48, 95% confidence interval (CI) 0.36 to 0.63] compared with single-chamber atrial pacing. The difference is primarily because of the development of AV block requiring upgrade to a dual-chamber device. The risk of paroxysmal atrial fibrillation was also reduced with dual-chamber pacing compared with single-chamber atrial pacing (OR 0.75, 95% CI 0.59 to 0.96). No statistically significant difference was found between the pacing modes for mortality, heart failure, stroke, chronic atrial fibrillation or quality of life. However, the risk of developing heart failure may vary with age and device. The de novo economic model shows that dual-chamber pacemakers are more expensive and more effective than single-chamber atrial devices, resulting in a base-case incremental cost-effectiveness ratio (ICER) of £6506. The ICER remains below £20,000 in probabilistic sensitivity analysis, structural sensitivity analysis and most scenario analyses and one-way sensitivity analyses. The risk of heart failure may have an impact on the decision to use dual-chamber or single-chamber atrial pacemakers. Results from an analysis based on age (> 75 years or ≤ 75 years) and risk of heart failure indicate that dual-chamber pacemakers dominate single-chamber atrial pacemakers (i.e. are less expensive and more effective) in older patients, whereas dual-chamber pacemakers are dominated by (i.e. more expensive and less effective) single-chamber atrial pacemakers in younger patients. However, these results are based on a subgroup analysis and should be treated with caution. CONCLUSIONS In patients with SSS without evidence of impaired AV conduction, dual-chamber pacemakers appear to be cost-effective compared with single-chamber atrial pacemakers. The risk of developing a complete AV block and the lack of tools to identify patients at high risk of developing the condition argue for the implantation of a dual-chamber pacemaker programmed to minimise unnecessary ventricular pacing. However, considerations have to be made around the risk of developing heart failure, which may depend on age and device. STUDY REGISTRATION This study is registered as PROSPERO CRD42013006708. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
|
4
|
|
5
|
Chiladakis JA, Koutsogiannis N, Kalogeropoulos A, Zagli F, Sihlimiris I, Alexopoulos D. Permanent and atrial-synchronized ventricular stimulation for clinically stable patients with normal or impaired left ventricular systolic function. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007; 30:182-7. [PMID: 17338713 DOI: 10.1111/j.1540-8159.2007.00647.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Ventricular desynchronization imposed by permanent dual-chamber ventricular pacing (VDD) may compromise ventricular function. METHODS We investigated the impact of background VDD pacing on the right and left ventricular (LV) function on 129 clinically stable outpatients (mean age 69 +/- 10) implanted chronically with a dual-chamber pacemaker or an automatic defibrillator by using echocardiographic techniques including tissue doppler imaging (TDI) and color M-mode (CMM) examinations, and B-type natriuretic peptide (BNP) measurements. Patients were divided into two groups of normal (n = 65) or impaired (n = 64) LV systolic function (ejection fraction 63 +/- 6% and 38 +/- 10%, respectively) according to clinical and echocardiographic criteria. Each patient group included two subgroups on the basis of the underlying permanent and atrial-synchronized heart rhythm: either intrinsic ventricular activation (IVA) or VDD pacing. RESULTS The BNP levels (mean, 95% CI) of patients with impaired LV systolic function were approximately threefold higher than those of patients with normal LV systolic function [189 (145-245) pg/mL vs 65 (50-85) pg/mL, P < 0.0001], but did not differ between subgroups of patients with IVA vs VDD pacing. By two-way analysis of variance and analysis of covariance, and after adjustment for age and gender, significant VDD pacing effects were found in terms of lower E/A ratio (P < 0.05) and increased LV end-systolic volume (P < 0.05). VDD pacing did not significantly affect the BNP levels and the LV filling pressures, as determined by the E/Ea and E/Vp ratios. CONCLUSIONS Long-term VDD pacing may not be harmful in clinically stable patients with normal or moderately reduced LV systolic function.
Collapse
Affiliation(s)
- John A Chiladakis
- Department of Cardiology, Patras University Hospital, 26500 Rion, Patras, Greece.
| | | | | | | | | | | |
Collapse
|
6
|
Chiladakis JA, Koutsogiannis N, Kalogeropoulos A, Alexopoulos D. Long-Term Effects of Atrial Synchronous Ventricular Pacing on Systolic and Diastolic Ventricular Function in Patients with Normal Left Ventricular Ejection Fraction. Cardiology 2007; 108:290-6. [PMID: 17284907 DOI: 10.1159/000099098] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2006] [Accepted: 08/08/2006] [Indexed: 11/19/2022]
Abstract
BACKGROUND Atrial synchronous right ventricular pacing (VP) may compromise ventricular function in patients undergoing pacemaker implantation for atrioventricular block. We assessed the usefulness of tissue Doppler imaging (TDI) and color M-mode echocardiography in evaluating patients with VP, and examined the long-term effects of VP on ventricular function by echocardiographic indices and B-type natriuretic peptide (BNP) measurements. METHODS We studied 60 clinically stable elderly dual-chamber pacemaker recipients (mean age: 74 +/- 9 years) who had normal left ventricular (LV) systolic function and on the long term the same cardiac rhythm, either intrinsic normal ventricular activation (IA) (n = 20), or VP (n = 40). RESULTS Paced patients, compared to patients with IA, had decreased stroke volume (p < 0.05) and a more depressed relaxation pattern, as indicated by decreased peak early mitral velocity (E)/peak atrial contraction velocity ratio and tissue Doppler imaging (TDI)-early transmitral diastolic velocity (Ea) measures (p < 0.05). Both groups presented similar BNP levels and LV filling pressures, as assessed by E/Ea and E/early diastolic transmitral flow propagation velocity. In VP patients, age (beta = 0.31), Ea (beta = -0.28) and E/Ea (beta = 0.32) emerged as independent predictors of BNP levels. CONCLUSIONS VP is associated with reduced LV systolic function and signs of impaired relaxation. Elevated BNP levels in elderly VP patients with normal ejection fraction may be predicted by TDI signs of LV diastolic dysfunction.
Collapse
Affiliation(s)
- John A Chiladakis
- Department of Cardiology, Patras University Hospital, Patras, Greece.
| | | | | | | |
Collapse
|
7
|
Kato M, Dote K, Sasaki S, Goto K, Takemoto H, Habara S, Hasegawa D, Matsuda O. Determination of the Optimal Atrioventricular Interval in Sick Sinus Syndrome During DDD Pacing. Pacing Clin Electrophysiol 2005; 28:892-7. [PMID: 16176525 DOI: 10.1111/j.1540-8159.2005.00210.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND Although the AAI pacing mode has been shown to be electromechanically superior to the DDD pacing mode in sick sinus syndrome (SSS), there is evidence suggesting that during AAI pacing the presence of natural ventricular activation pattern is not enough for hemodynamic benefit to occur. Myocardial performance index (MPI) is a simply measurable Doppler-derived index of combined systolic and diastolic myocardial performance. The aim of this study was to investigate whether AAI pacing mode is electromechanically superior to the DDD mode in patients with SSS by using Doppler-derived MPI. METHODS Thirty-nine SSS patients with dual-chamber pacing devices were evaluated by using Doppler echocardiography in AAI mode and DDD mode. The optimal atrioventricular (AV) interval in DDD mode was determined and atrial stimulus-R interval was measured in AAI mode. The ratio of the atrial stimulus-R interval to the optimal AV interval was defined as relative AV interval (rAVI) and the ratio of MPI in AAI mode to that in DDD mode was defined as relative MPI (rMPI). RESULTS The rMPI was significantly correlated with atrial stimulus-R interval and rAVI (r = 0.57, P = 0.0002, and r = 0.67, P < 0.0001, respectively). A cutoff point of 1.73 for rAVI provided optimum sensitivity and specificity for rMPI >1 based on the receiver operator curves. CONCLUSIONS Even though the intrinsic AV conduction is moderately prolonged, some SSS patients with dual-chamber pacing devices benefit from the ventricular pacing with optimal AV interval. MPI is useful to determine the optimal pacing mode in acute experiment.
Collapse
Affiliation(s)
- Masaya Kato
- Department of Cardiology, Hiroshima City Asa Hospital, 2-1-1 Kabeminami, Asakita-ku, Hiroshima 731-0293, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Yang A, Lüderitz B, Lewalter T. Atrial fibrillation: profit from cardiac pacing? ACTA ACUST UNITED AC 2005; 94:141-51. [PMID: 15747036 DOI: 10.1007/s00392-005-0196-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2004] [Accepted: 11/02/2004] [Indexed: 11/30/2022]
Abstract
The impact of cardiac pacing on the prevention of atrial fibrillation is under scientific investigation. Several prospective randomised clinical trials have reported that atrial-based "physiologic" AAI(R)- or DDD(R)-pacing is associated with a lower incidence of paroxysmal and permanent atrial fibrillation than single-chamber ventricular pacing in patients with a conventional pacemaker indication. However, it is still uncertain whether atrial pacing itself has independent antiarrhythmic properties. In contrast, right ventricular pacing is considered to promote atrial fibrillation, even in preserved AV synchrony during dual-chamber pacing. The electrical secondary prevention of atrial fibrillation is mainly based on variations of the atrial pacing site and sophisticated preventive pacing algorithms incorporated in the pacemaker software. Dual-site right atrial and biatrial pacing were reported to exhibit modest to no benefit for the prevention of atrial fibrillation, whereas septal pacing and specific preventive pacing algorithms have been demonstrated to reduce the incidence of atrial fibrillation in a number of clinical trials. However, the role of septal pacing and preventive pacing algorithms still has to be clarified since, overall, study results have been inconsistent so far. One of the main goals of future investigations should be the identification of responder groups of preventive pacing concepts. In clinical practice, the efficacy of pacing algorithms and septal pacing has to be determined in the individual case. These options should be taken into account in patients with symptomatic bradycardia as the indication for cardiac pacing and, in addition, symptomatic atrial fibrillation.
Collapse
Affiliation(s)
- A Yang
- Medizinische Klinik und Poliklinik II, Universitätsklinikum Bonn, Sigmund-Freud-Strasse 25, 53105 Bonn, Germany.
| | | | | |
Collapse
|
9
|
Pioger G, Jauvert G, Nitzsché R, Pozzan J, Henry L, Zigelman M, Leny G, Vandrell MC, Ritter P, Cazeau S. Incidence and predictive factors of atrial fibrillation in paced patients. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2005; 28 Suppl 1:S137-41. [PMID: 15683481 DOI: 10.1111/j.1540-8159.2005.00088.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
We have designed a prospective observational study to analyze the incidence and predictive factors of atrial fibrillation (AF) during a long follow-up, in a large population. Atrial fibrillation episodes were documented by the fallback mode switch (FMS) provided by implanted pacemakers. We have included 377 patients (61% men). The pacing indications were atrioventricular (AV) block (49%), sinus node disease (SND, 16%), bradycardia-tachycardia syndrome (BTS, 5%), AV block + SND (19%), AV block + BTS (6%), and BTS + SND (5%). The mean age at implant was 75 +/- 12 (range 28-95). Atrial fibrillation before inclusion was documented in 10% of patients. Drug therapy at first follow-up included beta-adrenergic blockers (17% of the patients), amiodarone (13%), and others (16%). The mean follow-up was 30 +/- 24 weeks. At least one AF episode was stored during follow-up in the memory of 169 pacemakers (45%). Among patients without history of AF at implant, 46% had documented FMS during follow-up. Patients with AF received more antiplatelet medications than patients without AF (P = 0.03). In patients with AF, New York Heart Association functional class was slightly higher, amiodarone and sotalol were more often prescribed, and the proportion of hypertension was higher than in patients without AF. However, these trends were not statistically significant. A significant higher incidence of premature atrial beats was observed in patients with AF than patients without AF (P < 0.0002). Patients with AF had a lower atrial percentage of paced events (55%) than patients without AF (63%, P < 0.02). These preliminary results confirm the high incidence of AF in paced patients and suggest a preventive effect of atrial pacing. The effects of other clinical variables may be confirmed with a longer follow-up in a larger population.
Collapse
Affiliation(s)
- Guy Pioger
- Clinique Alleray-Labrouste, Paris, France.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Savouré A, Fröhlig G, Galley D, Defaye P, Reuter S, Mabo P, Sadoul N, Amblard A, Limousin M, Anselme F. A New Dual-Chamber Pacing Mode to Minimize Ventricular Pacing. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2005; 28 Suppl 1:S43-6. [PMID: 15683522 DOI: 10.1111/j.1540-8159.2005.00095.x] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Despite the low long-term incidence of high-degree atrioventricular (AV) block and the known negative effects of ventricular pacing, programming of the AAI mode in patients with sinus node dysfunction (SND) remains exceptional. A new pacing mode was, therefore, designed to combine the advantages of AAI with the safety of DDD pacing. AAIsafeR behaves like the AAI mode in absence of AV block. First- and second-degree AV blocks are tolerated up to a predetermined, programmable limit, and conversion to DDD takes place in case of high-degree AV block. From DDD, the device may switch back to AAI, provided AV conduction has returned. The safety of AAIsafeR was examined in 43 recipients (70 +/- 12-year old, 24 men) of dual chamber pacemakers implanted for SND or paroxysmal AV block. All patients underwent 24-hour ambulatory electrocardiographic recordings before hospital discharge and at 1 month of follow-up with the AAIsafeR mode activated. No AAIsafeR-related adverse event was observed. At 1 month, the device was functioning in AAIsafeR in 28 patients (65%), and the mean rate of ventricular pacing was 0.2%+/- 0.4%. Appropriate switches to DDD occurred in 15 patients (35%) for frequent, unexpected AV block. AAIsafeR mode was safe and preserved ventricular function during paroxysmal AV block, while maintaining a very low rate of ventricular pacing. The performance of this new pacing mode in the prevention of atrial fibrillation will be examined in a large, controlled study.
Collapse
|
11
|
Mani H, Shirayama T, Suzaki Y, Sakatani T, Sakamoto T, Yamamura M, Matsubara H, Taniwaki M. Clinical Significance of Preserving Spontaneous QRS Wave in the Therapy of DDD Pacing for Sick Sinus Syndrome. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2004; 27:1212-6. [PMID: 15461710 DOI: 10.1111/j.1540-8159.2004.00611.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The aim of this clinical crossover study was to elucidate the effects of atrioventricular (AV) synchronous pacing on cardiac function in patients with sick sinus syndrome (SSS). Thirty SSS patients, each with dual chamber pacemaker (DDD), were enrolled and divided into two groups based on echocardiographic findings. Group A (n = 16) had hypertensive heart disease (wall thickness 11 approximately 12 mm) or mitral or aortic regurgitation (Grade I or II). Group B (n = 14) had no organic heart disease. Three successive 3-month pacing periods were tested. For the first 3 months, long AV delay that achieved > 80% ventricular sensing was chosen. For the next 3 months, AV delay was abbreviated to achieve > 80% ventricular pacing at an optimal AV interval. For the final 3 months, the first setting was resumed. At the end of each period, M mode echocardiography, pulsed-Doppler study, and measurement of plasma brain natriuretic peptide (BNP) level were conducted. In both groups, echocardiographic parameters were not significantly changed during the evaluation. In group A, plasma BNP level was significantly higher at the end of the short AV delay period than at the long AV delay period (P = 0.009), while in group B it did not differ during each period. AV synchronous pacing (> 80% ventricular pacing) in the SSS patients with a DDD pacemaker implanted could increase the ventricular load, and it is better to preserve the spontaneous QRS with the DDD mode with prolonged AV delay in patients with mild hypertensive or valvular disease.
Collapse
Affiliation(s)
- Hiroki Mani
- Department of Clinical Molecular Genetics and Laboratory Medicine, Kyoto Prefectural University of Medicine, Kyoto, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Moríñigo JL, Arribas A, Ledesma C, Sánchez PL, Martín F, Martín Luengo C. [Clinical safety and efficacy of single-chamber atrial pacing in sick sinus syndrome: long-term follow-up]. Rev Esp Cardiol 2002; 55:1267-72. [PMID: 12459076 DOI: 10.1016/s0300-8932(02)76799-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
INTRODUCTION AND OBJECTIVES Although atrial pacing is a more physiological mode of stimulation in sinus node dysfunction, the pacing modes most often are used DDD and VVI. The aim of our study was to demonstrate that AAI/AAIR pacing is effective and safe by analyzing the complications and mortality of this pacing mode in a long-term follow-up study. PATIENTS AND METHOD Between 1982 and 2000 definitive AAI-mode pacemakers were implanted for sinus node dysfunction in mode AAI in 160 patients. We analyzed the clinical characteristics, evolution, and complications of the AAI pacing mode during a follow-up of 5.4 4.5 years. RESULTS The sample was made up of 104 women and 56 men with an average age of 72 12 years. During follow-up, it was necessary to change the pacing mode for symptomatic bradycardia in 11 patients (annual incidence 1.2%), which was caused by second or third-degree atrioventricular block in 7 patients (annual incidence 0.8%), and chronic atrial fibrillation with bradycardia in 4 patients (annual incidence 0.4%). During follow-up, atrial arrhythmias occurred in 32 patients (annual incidence 3.7%), stroke in 4 patients (annual incidence 0.4%), and 27 patients (annual incidence 3.1%) died. CONCLUSIONS The AAI/AAIR pacing mode was safe and effective in sinus node dysfunction, with a low percentage of pacing changes required for progression to atrioventricular block, low incidence of atrial arrhythmias, stroke and low mortality during long term follow-up.
Collapse
Affiliation(s)
- Jose L Moríñigo
- Servicio de Cardiología. Hospital Clínico Universitario de Salamanca. España.
| | | | | | | | | | | |
Collapse
|