1
|
Machado P, Stanczak M, Liu JB, Moore JN, Eisenbrey JR, Needleman L, Kraft WK, Forsberg F. Subdermal Ultrasound Contrast Agent Injection for Sentinel Lymph Node Identification: An Analysis of Safety and Contrast Agent Dose in Healthy Volunteers. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2018; 37:1611-1620. [PMID: 29205451 PMCID: PMC5988650 DOI: 10.1002/jum.14502] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2017] [Revised: 08/21/2017] [Accepted: 09/14/2017] [Indexed: 05/05/2023]
Abstract
OBJECTIVES Mapping of the lymphatic chain for identification of the sentinel lymph node (SLN) is an important aspect of predicting outcomes for patients with breast cancer, and it is usually performed as an intraoperative procedure using blue dye and/or radiopharmaceutical agents. Recently, the use of contrast-enhanced ultrasound (CEUS) has been proposed as an alternative imaging technique for this mapping. The objective of this study was to evaluate the use of subdermal administration of the ultrasound (US) contrast agent Sonazoid (GE Healthcare, Oslo, Norway) in terms of patient safety and to select the dose to be used for lymphatic applications in humans. METHODS This study was performed in 12 female volunteers who received bilateral subdermal injections of Sonazoid (1 or 2 mL dose) in the mid-upper outer quadrant of their breasts at 2 different time points. Contrast-enhanced US examinations were performed 0, 0.25, 0.5, 1, 2, 4, 6, and 24 hours after injection to identify SLNs. RESULTS Sentinel lymph nodes were identified within the first hour after injection as enhanced structures, and there was no significant difference by dose in the number of SLNs identified (P = .74). The volunteers only had minor adverse experiences (AEs) that resolved completely without intervention by study completion. CONCLUSIONS The subdermal use of Sonazoid in this study showed only minor local and nonsignificant AEs that were completely resolved without any intervention. Two different doses were compared with no significant differences observed between them. Hence, the lower dose studied (1 mL) was selected for use in future clinical studies.
Collapse
Affiliation(s)
- Priscilla Machado
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| | - Maria Stanczak
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| | - Ji-Bin Liu
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| | - Jason N. Moore
- Department of Pharmacology and Experimental Therapeutics, Thomas Jefferson University, Philadelphia, PA, USA
| | - John R. Eisenbrey
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| | - Laurence Needleman
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| | - Walter K. Kraft
- Department of Pharmacology and Experimental Therapeutics, Thomas Jefferson University, Philadelphia, PA, USA
| | - Flemming Forsberg
- Department of Radiology, Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
2
|
Goldberg BB, Merton DA, Liu JB, Forsberg F, Zhang K, Thakur M, Schulz S, Schanche R, Murphy GF, Waldman SA. Contrast-enhanced ultrasound imaging of sentinel lymph nodes after peritumoral administration of Sonazoid in a melanoma tumor animal model. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2011; 30:441-453. [PMID: 21460143 DOI: 10.7863/jum.2011.30.4.441] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
OBJECTIVES The purpose of this study was to compare lymphosonography (ie, contrast-enhanced ultrasound imaging [US] after interstitial injection of a US contrast agent) for the detection of sentinel lymph nodes (SLNs) in swine with naturally occurring melanoma tumors to lymphoscintigraphy using blue dye-guided surgical dissection as the reference standard. Also, we sought to determine if lymphosonography can be used to characterize SLNs. METHODS Sixty-three swine with 104 melanomas were evaluated. Contrast-specific US was performed after peritumoral injection (1 mL dose) of Sonazoid (GE Healthcare, Oslo, Norway). Lymphoscintigraphy was performed after peritumoral injections of technetium Tc 99m sulfur colloid. Peritumoral injection of 1% Lymphazurin (Ben Venue Labs, Inc, Bedford, OH) was used to guide SLN resection. The accuracy of SLN detection with the two imaging modalities was compared using the McNemar test. The SLNs were qualitatively and quantitatively characterized as benign or malignant based on the lymphosonography results with histopathology and RNA analyses used as the reference standards. RESULTS Blue dye-guided surgery identified 351 SLNs. Lymphosonography detected 293 SLNs and 11 false-positives, while lymphoscintigraphy detected 231 SLNs and 20 false-positives. The accuracy of SLN detection was 81.8% for lymphosonography, which was significantly higher than the 63.2% achieved with lymphoscintigraphy (P < .0001). The accuracy of lymphosonography for SLN characterization was 80%. When the size of the enhanced SLN was taken into consideration to characterize SLNs, the accuracy was 86%. CONCLUSIONS Lymphosonography is statistically better than lymphoscintigraphy for the detection of SLNs in this animal model. The ability to use lymphosonography as a means to characterize SLNs as benign or malignant is limited.
Collapse
Affiliation(s)
- Barry B Goldberg
- Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA 19107, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Argon AM, Duygun U, Acar E, Daglioz G, Yenjay L, Zekioglu O, Kapkac M. The use of periareolar intradermal Tc-99m tin colloid and peritumoral intraparenchymal isosulfan blue dye injections for determination of the sentinel lymph node. Clin Nucl Med 2007; 31:795-800. [PMID: 17117076 DOI: 10.1097/01.rlu.0000246855.80027.b7] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE The purpose of the present study was to evaluate the use of lymphoscintigraphy, blue dye, and gamma probe detection methods for determination of the sentinel lymph node (SLN) using both periareolar intradermal injection of Tc-99m tin colloid and peritumoral intraparenchymal injection of isosulfan blue dye. METHODS One hundred patients with T1-2 breast cancer and clinically negative nodes were enrolled in the present study. The study was composed of 2 groups. Backup axillary lymph node dissection (ALND) was mandatory in group 1 (20 patients) regardless of their lymph node status. In group 2 (80 patients), complete ALND was performed when intraoperative frozen section analysis of SLN revealed metastases. Otherwise, only SLN biopsy was performed without ALND. One day before surgery, Tc-99m tin colloid was injected at 4 periareolar sites intradermally. Lymphoscintigraphy was performed 1 to 2 hours after injection of the radiocolloid. Twenty minutes before surgery, isosulfan blue dye was injected into parenchyma surrounding the tumor or the biopsy cavity. RESULTS The detection rates of SLN and false-negative rate of lymphoscintigraphy, blue dye, and gamma probe detection were 85%, 95% 100%, and 0% in group 1, 91%, 87%, and 95% in group 2, respectively. Detection rate by the combination of blue dye and radio tracer was 98%. CONCLUSIONS According to the results of our study, we conclude that perioareolar intradermal injection of Tc-99m tin colloid combined with peritumoral intraparenchymal injection of blue dye is an accurate and easy method of locating the sentinel node with very high detection rates. It is recommended that the combination of all methods such as lymphoscintigraphy, blue dye, and gamma probe application will increase the success rate of SLN detection in patients with breast cancer.
Collapse
Affiliation(s)
- Aziz Murat Argon
- Department of Nuclear Medicine, Ege University Medical Faculty, Izmir, Turkey.
| | | | | | | | | | | | | |
Collapse
|
4
|
Takei H, Suemasu K, Kurosumi M, Ninomiya J, Horii Y, Inoue K, Tabei T. 99mTc-phytate is better than 99mTc-human serum albumin as a radioactive tracer for sentinel lymph node biopsy in breast cancer. Surg Today 2006; 36:219-24. [PMID: 16493529 DOI: 10.1007/s00595-005-3128-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2004] [Accepted: 07/12/2005] [Indexed: 02/06/2023]
Abstract
PURPOSE Several radioactive agents are used for sentinel lymph node biopsy (SLNB) in breast cancer, but we are still unsure which of these is best. We retrospectively compared the effectiveness of two radioactive agents, 99mTc-phytate and 99mTc-human serum albumin (HSA), when used in combination with blue dye. METHODS A consecutive series of 533 clinically node-negative patients with a collective 539 breast carcinomas were divided into two groups for treatment with SLNB. The HSA-group consisted of 264 patients (with a collective 266 breast cancers) and the P-group consisted of 269 patients (with a collective 273 breast cancers) treated with 99mTc-HSA and 99mTc-phytate, respectively, in combination with blue dye. We analyzed the identification and radioactivity of SLNs in the two groups. RESULTS The identification rate of SLN was significantly higher in the P-group than in the HSA-group. The same results were produced by analysis using the radioactive agent alone, but not by using the blue dye alone. Most importantly, the highest radioactivity of SLNs per case was more than five times higher in the P-group than in the HSA-group, and this difference was significant. CONCLUSION Our historical analysis of the two radioactive agents used in different periods could not exclude the influence of the improved skill of the surgeons. However, because the specific accumulation of phytate in SLNs was greater than that of HSA, phytate might result in a higher SLN identification rate. Thus, 99mTc-phytate is better than 99mTc-HSA as a radioactive agent for SLNB in breast cancer.
Collapse
Affiliation(s)
- Hiroyuki Takei
- Division of Breast Surgery, Saitama Cancer Center, 818 Komuro, Ina-machi, Kitaadachi, Saitama, 362-0806, Japan
| | | | | | | | | | | | | |
Collapse
|
5
|
Ikeda T, Jinno H, Fujii H, Kitajima M. Recent development of sentinel lymph node biopsy for breast cancer in Japan. Asian J Surg 2005; 27:275-8. [PMID: 15564178 DOI: 10.1016/s1015-9584(09)60050-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
The number of breast cancer cases undergoing sentinel lymph node biopsy (SLNB) has been increasing with the number of articles published in Japan. SLNB using the dye method alone is performed in about one-third of patients. Analysis of questionnaire responses from 40 institutions in Japan revealed an identification rate by the dye method alone of 87%, compared with 96% using the combined method; the combined method is now recognized in Japan as superior to the dye method alone. No dyes have been specifically approved by the government for use in SLNB, and physicians have been using several inappropriate dyes as tracers for SLNB, such as indocyanine green, patent blue, indigo carmine, and isosulfan blue. The colloidal radiotracers used in Japan include tin colloid, stannous phytate, rhenium sulfate and human serum albumin. Albumin colloid and sulfur colloid are not commercially available in Japan. Small-size tin colloids, stannous phytate and rhenium sulfate all yield good results in terms of detection and false-negative rates. Provided that the surgeon has adequate experience in SLNB, a negative sentinel node can serve as a substitute for negative results from axillary lymph node dissection. Although many institutions have introduced SLNB, few reports have focused on the results of SLNB without axillary dissection because of short follow-up times and small number of patients. The final decision as to whether SLNB is an adequate substitute for axillary dissection awaits the results of prospective randomized trials.
Collapse
Affiliation(s)
- Tadashi Ikeda
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan.
| | | | | | | |
Collapse
|
6
|
Sirlin CB, Vera DR, Corbeil JA, Caballero MB, Buxton RB, Mattrey RF. Gadolinium-DTPA-dextran: a macromolecular MR blood pool contrast agent. Acad Radiol 2004; 11:1361-9. [PMID: 15596374 DOI: 10.1016/j.acra.2004.11.016] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2004] [Revised: 07/07/2004] [Accepted: 10/14/2004] [Indexed: 10/26/2022]
Abstract
RATIONALE AND OBJECTIVES Magnetic resonance (MR) imaging blood pool agents offer numerous advantages for vascular and tumor imaging. The purpose of this study was to test gadolinium-diethylenetriaminepentaacetate-dextran ([Gd]DTPA-dextran) as a new water soluble macromolecular blood pool agent for MR imaging. MATERIALS AND METHODS [Gd]DTPA-dextran (187 gadolinium atoms per dextran, molecular weight 165 kD, diameter 17.6 nm) was synthesized. Fifteen anesthetized New Zealand White rabbits with thigh VX2 tumors were scanned in a knee coil at 1.5T. Coronal 3D MR angiographic sequences were obtained before and at several time points up to 72 hours after the intravenous bolus injection of [Gd]DTPA-dextran providing gadolinium at either 0.05 (n = 4) or 0.1 mmol/kg (n = 8) or [Gd]DTPA-bismethylamide (BMA) providing gadolinium at 0.1 mmol/kg (n = 3). Time enhancement curves for aorta, cava, and tumor rim were compared by univariate General Linear Model. RESULTS Contrast enhancement of cava and aorta relative to a water phantom were significantly greater at all time points after either dose of [Gd]DTPA-dextran than after [Gd]DTPA-BMA (P < 0.01). Tumor rim enhancement was less intense for either dose of [Gd]DTPA-dextran at peak than for [Gd]DTPA-BMA (P < 0.05). Tumor rim enhancement with both doses of [Gd]DTPA-dextran became equivalent to that of [Gd]DTPA-BMA at one hour and was greater at 24 hours (P < 0.05). CONCLUSION [Gd]DTPA-dextran is a new macromolecular MR contrast agent that can be synthesized to carry a high density of gadolinium atoms without intra-molecular cross-linking. It provides significantly greater vascular residence time than a conventional gadolinium chelate and shows promise for MR blood pool imaging.
Collapse
Affiliation(s)
- Claude B Sirlin
- Department of Radiology, University of California, San Diego, 200 West Arbor Drive, San Diego, CA, USA
| | | | | | | | | | | |
Collapse
|
7
|
Takagi K, Uehara T, Kaneko E, Nakayama M, Koizumi M, Endo K, Arano Y. 99mtc-labeled mannosyl-neoglycoalbumin for sentinel lymph node identification. Nucl Med Biol 2004; 31:893-900. [PMID: 15464391 DOI: 10.1016/j.nucmedbio.2004.04.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2003] [Revised: 04/13/2004] [Accepted: 04/26/2004] [Indexed: 10/26/2022]
Abstract
99mTc-labeled mannosyl-neoglycoalbumin (NMA) was prepared and evaluated as a radiopharmaceutical for sentinel lymph node (SLN) identification, since 99mTc-labeled human serum albumin (HSA) rapidly cleared from injection sites. NMA was conjugated with 6-hydrazinopyridine-3-carboxylic acid (HYNIC) and reacted with [99mTc](tricine)2 to prepare [99mTc](HYNIC-NMA)(tricine)2. After subcutaneous injection of [99mTc](HYNIC-NMA)(tricine)2 from murine foot pad, radioactivity levels in the popliteal and lumbar lymph nodes, the injection site and other tissues were compared with those of [99mTc](HYNIC-HSA)(tricine)2 and 99mTc-labeled colloidal rhenium sulfate ([99mTc]colloid). [99mTc](HYNIC-NMA)(tricine)2 demonstrated significantly higher radioactivity levels in the popliteal lymph node, the SLN in this model, than did [99mTc](HYNIC-HSA)(tricine)2 and [99mTc]colloid at 0.5, 1, and 6 h post-injection. [99mTc](HYNIC-NMA)(tricine)2 showed a dose-dependent decrease in the popliteal accumulation while the radioactivity levels in the blood, liver and spleen increased with an increase in the molar dose of NMA. [99mTc]colloid registered a decrease in the radioactivity levels in the popliteal lymph node, blood, liver, and spleen with dilution. However, the radioactivity levels at the injection site increased with dilution of [99mTc] colloid. Both [99mTc](HYNIC-NMA)(tricine)2 and [99mTc](HYNIC-HSA)(tricine)2 showed the radioactivity levels at the injection site similar each other. These findings indicated that an addition of a macrophage binding function to 99mTc-labeled HSA provided high and selective accumulation of the radioactivity in the SLN without affecting the elimination rate from the injection site. Such characteristics render [99mTc](HYNIC-NMA)(tricine)2 attractive as a radiopharmaceutical for SLN identification. This study also demonstrated that the number of non-radiolabeled colloidal particles and the molar dose of mannosylated compounds play a crucial role in the SLN accumulation.
Collapse
Affiliation(s)
- Kyoko Takagi
- Graduate School of Pharmaceutical Sciences, Chiba University, 1-8-1 Inohana, Chuo-ku, 260-8675, Chiba, Japan
| | | | | | | | | | | | | |
Collapse
|
8
|
Sato K, Krag D, Tamaki K, Anzai M, Tsuda H, Kosuda S, Kusano S, Hiraide H, Mochizuki H. Optimal particle size of radiocolloid for sentinel node identification in breast cancer — Electron microscopic study and clinical comparison. Breast Cancer 2004; 11:256-63; discussion 264-6. [PMID: 15550844 DOI: 10.1007/bf02984546] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND Sentinel node (SN) biopsy using a radiotracer is easy to learn, reproducible, and performed by the majority of breast cancer surgeons. However, this technique raises the question: what is the optimal particle size of colloid? METHODS Patients were injected with conventional tin colloid (median particle diameter: 700 nm) and the predominant particle size of radiocolloid retained in the SN was measured using electron microscopy. This showed a narrow distribution of colloidal size (100-150 nm). Patients were then injected with modified tin colloid having a median particle size of 100 nm. A clinical comparison was performed between conventional particle size or reduced particle size tin colloid and the SN biopsy success rate, the number of SNs, and the colloidal uptake in SNs. RESULTS A total of 118 patients were injected with the conventional tin colloid (group I) and 124 patients with the smaller particle colloid (group II). The identification rate and the number of SN in both groups were almost equal, and the patients with low-uptake SNs were not significantly less in group I(p = 0.55). However, in the subgroup of patients 60 years of age or more, group II had significantly more SNs than group I(1.4 vs 1.9; p = 0.03) and low-uptake SNs were significantly less common than in group I(p = 0.02). CONCLUSIONS The improvement of colloidal uptake in SNs using the smaller particle size tin colloid was confirmed, and this impact was statistically significant in the older population.
Collapse
Affiliation(s)
- Kazuhiko Sato
- Breast Oncology Center, Dana-Farber Cancer Institute 44 Binney Street, Boston, Massachusetts 02115, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Sato K, Tamaki K, Tsuda H, Kosuda S, Kusano S, Hiraide H, Mochizuki H. Utility of axillary ultrasound examination to select breast cancer patients suited for optimal sentinel node biopsy. Am J Surg 2004; 187:679-83. [PMID: 15191856 DOI: 10.1016/j.amjsurg.2003.10.012] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2003] [Revised: 10/17/2003] [Indexed: 10/26/2022]
Abstract
BACKGROUND Because sentinel node (SN) biopsy (SNB) is known to produce false-negative results, we examined the usefulness of axillary ultrasound (AUS) in selecting patients suitable for optimal SNB. METHODS A positive AUS finding (positive AUS) was defined as an echo pattern of a homogeneously hypoechoic SN without an echo-rich center, indicating massive to extensive nodal involvement. The identification of SNs was performed, and complete axillary dissection was carried out. RESULTS A total of 262 women were enrolled into the study (T1 disease = 94; T2 disease = 145; and T3 disease = 23). The incidence of positive AUS increased with increasing size of breast tumor (P <0.0001). The overall identification and false-negative rates were 88.2% and 10.8%, respectively. However, when limited to AUS-negative patients, SNs were identified in 205 of 208 patients (98.6%), and the false-negative rate was 1.7%. CONCLUSIONS AUS should be included in the preoperative procedure for the selection of breast cancer patients suitable for SNB.
Collapse
Affiliation(s)
- Kazuhiko Sato
- Department of Surgery I, National Defense Medical College, 3-2 Namiki, Tokorozawa, Saitama 359-8513, Japan.
| | | | | | | | | | | | | |
Collapse
|
10
|
Ueda K, Suga K, Kaneda Y, Sakano H, Tanaka T, Hayashi M, Li TS, Hamano K. Radioisotope lymph node mapping in nonsmall cell lung cancer: can it be applicable for sentinel node biopsy? Ann Thorac Surg 2004; 77:426-30. [PMID: 14759410 DOI: 10.1016/s0003-4975(03)01351-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/03/2003] [Indexed: 11/26/2022]
Abstract
BACKGROUND Previous studies on intrathoracic lymph node mapping have focused on the validity of a sentinel node concept, but not on the usefulness for sentinel node biopsy. METHODS The subjects were 15 patients clinically diagnosed with N0 nonsmall cell lung cancer. Technetium-99m tin colloid was injected into the peritumoral area 1 day preoperatively and a time course of tracer migration was monitored by scintigraphy. A hand-held gamma probe counter was used to count the intrathoracic lymph node stations. Resected nodes were also counted to assess the accuracy of the intrathoracic counting. RESULTS Serial scintigraphies showed that the tracer migrated through airways and the appearance resembled hot nodes. On intrathoracic counting, 50% of the nodal stations appeared positive; however, only 23% of these apparently positive nodal stations were ultimately shown to be truly radioactive. The true positive and true negative rates of detecting intrathoracic hot nodes were 100% and 56%, respectively. Because the counts of the nodal stations could include the counts from the hot primary tumor ("shine-through") or airway radioactivity, legitimate hot nodes were identified after dissecting all the apparently positive nodal stations. Two of the 9 patients in whom hot nodes were identified had nodal metastatic disease and actually had tumor cells within the hot nodes. The only complication related to the preoperative injection of technetium-99m was a minor pneumothorax. CONCLUSIONS Although radioisotope intrathoracic lymph node mapping is safe, it appears to be unsuitable for sentinel node biopsy because shine-through and the airway-migrated radioactive tracer complicated the intrathoracic counting. Only serial scintigraphy could distinguish hot nodes from airway migration.
Collapse
Affiliation(s)
- Kazuhiro Ueda
- First Department of Surgery, Yamaguchi University School of Medicine, Ube Yamaguchi, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Ikeda T, Jinno H, Kitagawa Y, Kitajima M. Emerging patterns of practice in the implementation and application of sentinel lymph node biopsy in breast cancer patients in Japan. J Surg Oncol 2003; 84:173-5. [PMID: 14598362 DOI: 10.1002/jso.10313] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Tadashi Ikeda
- Department of Surgery, Keio University School of Medicine, Tokyo, Japan.
| | | | | | | |
Collapse
|