Delayed gamma fraction determination in the zero power reactor CROCUS. EPJ NUCLEAR SCIENCES & TECHNOLOGIES 2021. [DOI: 10.1051/epjn/2021015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Gamma rays are an inextricable part of a nuclear reactor’s radiation field, and as such require characterization for dose rate estimations required for the radiation protection of personnel, material choices, and the design of nuclear facilities. Most commonplace radiation transport codes used for shielding calculations only included the prompt neutron induced component of the emitted gamma rays. The relative amount of gamma rays that are emitted from delayed processes – the delayed gamma fraction – amount to a significant contribution, e.g. in a typical zero power reactor at steady state is estimated to be roughly a third. Accurate predictions of gamma fields thus require an estimation of the delayed content in order to meaningfully contribute. As a consequence, recent code developments also include delayed gamma sources and require validation data. The CROCUS zero power research reactor at EPFL is part of the NEA IRPhE and has therefore been characterized for benchmark quality experiments. In order to provide the means for delayed gamma validation, a dedicated experimental campaign was conducted in the CROCUS reactor using its newly developed gamma detection capabilities based on scintillators. In this paper we present the experimental determination of the delayed gamma fraction in CROCUS using in-core neutron and gamma detectors in a benchmark reactor configuration. A consistent and flexibly applicable methodology on how to estimate the delayed gamma fraction in zero power reactors has hitherto not existed – we herein present a general experimental setup and analysis technique that can be applied to other facilities. We found that the build-up time of relevant short lived delayed gamma emitters is likely attributed to the activation of the aluminium cladding of the fuel. Using a CeBr3 scintillator in the control rod position of the CROCUS core, we determined a delayed gamma fraction of (30.6±0.6)%.
Collapse
|
2
|
Abstract
The present article provides an overview of the design of a three-dimensional (3D) full-core mapping system for the CROCUS reactor, operated at the École polytechnique fédérale de Lausanne (EPFL), Switzerland. The system is composed of 149 miniature neutron detectors distributed within the core double lattice at three main axial levels. The miniature detector technology is based on the optimization of the well-proven coupling of a miniature ZnS:6LiF(Ag) scintillator to a state-of-the-art silicon photomultiplier (SiPM) via jacketed optical fibers. The challenges in the mechanical design, the detector optimization, the core criticality, and the development of the acquisition electronics are strongly interconnected and their combination is addressed in this article. The 3D full-core mapping system is foreseen to be installed in CROCUS in autumn 2021 and it will pave the way for the investigation of 3D dynamic phenomena in nuclear reactor cores.
Collapse
|
3
|
The COLIBRI experimental program in the CROCUS reactor: characterization of the fuel rods oscillator. EPJ WEB OF CONFERENCES 2020. [DOI: 10.1051/epjconf/202022504020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The present article presents the mechanical characterization of the fuel rods oscillator developed for the purposes of the COLIBRI experimental program in CROCUS. COLIBRI aims at investigating the radiation noise related to fuel vibrations. The main motivation is the increased amplitudes in the neutron noise distributions recorded in ex- and in-core detectors that have been observed in recent years in Siemens pre-Konvoi type of pressurized water reactors. Several potential explanations have been put forward, but no definitive conclusions could yet be drawn. Among others, changes in fuel assembly or pin vibration patterns, due to recent modifications of assembly structural designs, were pointed out as a possible cause. Computational dynamic tools are currently developed within the Horizon 2020 European project CORTEX, to help with understanding the additional noise amplitude. The COLIBRI program is used for their validation. An in-core device was designed, tested, and licensed between 2015 and 2019 for fuel rods oscillation in CROCUS, in successive steps from out-of-pile tests with dummy fuel rods to critical in-core tests. The characterization of its mechanical behavior is presented, in air and in water, and as a function of the load, for safety and experimental purposes. The device allows simultaneously oscillating up to 18 fuel rods. The maximum oscillation amplitude is 5 mm, while the maximum allowed frequency is 2 Hz, i.e. in the frequency range in which the induced neutron flux fluctuations are most pronounced in nuclear power plants.
Collapse
|
4
|
Abstract
In the present article, we detail the method used to experimentally determine the power of the CROCUS zero-power reactor, and to subsequently calibrate its ex-core monitor fission chambers. Knowledge of the reactor power is a mandatory quantity for a safe operation. Furthermore, most experimental research programs rely on absolute fission rates in design and interpretation – for instance, tally normalization of reaction rate studies in dosimetry, or normalization of power spectral density in neutron noise measurements. The minimization of associated uncertainties is only achieved by an accurate power determination method. The main experiment consists in the irradiation, and therefore, the activation of several axially distributed Au-197 foils in the central axis of the core, which activities are measured with a High-Purity Germanium (HPGe) gamma spectrometer. The effective cross sections are determined by MCNP and Serpent Monte Carlo simulations. We quantify the reaction rate of each gold foil, and derive the corresponding fission rate in the reactor. The variance weighted average over the distributed foils then provides a calibration factor for the count rates measured in the fission chambers during the irradiation. We detail the calibration process with minimization of respective uncertainties arising from each sub-step, from power control after reactivity insertion, to the calibration of the HPGe gamma spectrometer. Biases arising from different nuclear data choices are also discussed.