Chen Z, Zhao H, Zhao Y, Han J, Yang X, Throckmorton A, Wei Z, Ge S, He Y. Retrograde flow in aortic isthmus in normal and fetal heart disease by principal component analysis and computational fluid dynamics.
Echocardiography 2022;
39:166-177. [PMID:
35026051 DOI:
10.1111/echo.15256]
[Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 10/04/2021] [Accepted: 10/28/2021] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVES
Reverse flow Retrograde flow (RF) of blood in the aortic isthmus can be observed in different types of fetal heart disease (FHD), including abnormalities in heart structure and function. This study sought to investigate the relationship between RF and blood flow parameters, and develop a computational fluid dynamics (CFD) model to understand the mechanisms underlying this observation.
MATERIAL AND METHODS
A total of 281 fetuses (gestational age [GA] 26.6±.3 weeks) with FHD and 2803 normal fetuses (GA: 26.1±.1 weeks) by fetal echocardiography collected from May 2016 to December 2018. Principal component analysis (PCA) was performed to find the relationship and the CFD model reconstructed from 3D/4D spatio-temporal image correlation (STIC) images to simulate hemodynamics.
RESULTS
There was a significant difference in the percentages of RF between the study (80/201 (39%)) and control (29/2803 (1%)) groups (p < 0.05). The RF occur when the aorta flow rate (left heart) is reduced to 60% by CFD stimulation. Pearson correlation analysis showed significant correlations between flow rate and wall shear stress(WSS) (r = .883, p = 0.047) variables at the AI.
CONCLUSION
Volumetric flow rate of AO or left heart was the main component of the cause of RF. The hemodynamics of the cardiovascular system have highly complex behavior hinge on the turbulent nature of circulating blood flow.