1
|
Contrast-enhanced Imaging in Peripheral Pulmonary Lesions: The Role in US-guided Biopsies. Radiol Cardiothorac Imaging 2024; 6:e230234. [PMID: 38695742 DOI: 10.1148/ryct.230234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2024]
Abstract
Purpose To compare the tissue adequacy and diagnostic accuracy of US-guided biopsies of peripheral pulmonary lesions (PPLs) with and without contrast agents. Materials and Methods A retrospective study was conducted at four medical centers in patients with PPLs who underwent US-guided percutaneous transthoracic needle biopsy (PTNB) between January 2017 and October 2022. The patients were divided into contrast-enhanced US (CEUS) and US groups based on whether prebiopsy CEUS evaluation was performed. Tissue adequacy and the diagnostic accuracy of PTNB, stratified by lesion size, were analyzed and compared between groups. A propensity score matching (PSM) analysis was conducted using the nearest-neighbor matching method. Results A total of 1027 lesions were analyzed, with 634 patients (mean age, 59.4 years ± 13.0 [SD]; 413 male) in the US group and 393 patients (mean age, 61.2 years ± 12.5; 270 male) in the CEUS group. The CEUS group produced more acceptable samples than the US group (98.2% vs 95.7%; P = .03) and achieved higher diagnostic accuracy (96.9% vs 94.2%; P = .04), with no evidence of a difference in sensitivity (96.7% vs 94.0%; P = .06). PSM and stratified analyses (n = 358 per group) indicated higher tissue adequacy (99.0% vs 95.7%; P = .04) and diagnostic accuracy (98.5% vs 92.9%; P = .006) in the CEUS group compared with the US group for 2-7-cm PPLs but not for lesions larger than 7 cm. Conclusion PTNB with prebiopsy CEUS evaluation demonstrated significantly better tissue adequacy and diagnostic accuracy compared with US guidance alone for PPLs ranging from 2 to 7 cm, with similar biopsy performance achieved between groups for lesions larger than 7 cm. Keywords: Contrast Material, Thoracic Diseases, Ultrasonography, Image-Guided Biopsy © RSNA, 2024.
Collapse
|
2
|
Abdominal ultrasound in the characterization of branch-duct intraductal papillary mucinous neoplasms: A new tool for surveillance of low-risk patients? Dig Liver Dis 2024; 56:1071-1077. [PMID: 38042636 DOI: 10.1016/j.dld.2023.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/06/2023] [Accepted: 11/07/2023] [Indexed: 12/04/2023]
Abstract
BACKGROUND Magnetic resonance imaging (MRI) is regarded as gold-standard for intraductal papillary mucinous neoplasms (IPMNs) follow-up. Given the low risk of transformation and the increasing population under surveillance, there is growing interest in identifying optimal follow-up strategies. AIM To evaluate reliability of abdominal ultrasound (US) for characterization of low-risk IPMN, compared to MRI. METHODS Prospective monocentric study among 79 consecutive patients with a suspected BD-IPMN on US. Each patient underwent confirmatory MRI. We evaluated Cohen's kappa statistic and concordance rate (CR) between MRI and US. RESULTS Of 79 suspected IPMNs on US, MRI confirmed 71 BD-IPMNs. There was high agreement for cyst location and number (CR and kappa of 77.5 % and 81.7 % and 0.66±0.08 and 0.62±0.11 respectively). We found high agreement for cyst size (CR=96.5 %, kappa=0.93±0.05) and main pancreatic duct (MPD) dilatation (CR=100 %, kappa=1). There was a good agreement for thickened septa (CR=80.3 %, kappa=0.38±0.12). US seems inferior to MRI for the identification of mural nodules < 5 mm (CR=97.2 %, kappa=0). CONCLUSIONS In a cohort of low-risk BD-IPMN, US presented high agreement rate with MRI regarding location, number, and size. There was a good agreement for MPD dilatation and thickened septa, while US underperform for detection of mural nodules < 5 mm.
Collapse
|
3
|
Development of a Novel Contrast-Enhanced Ultrasound-Based Nomogram for Superficial Lymphadenopathy Differentiation: Postvascular Phase Value. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:852-859. [PMID: 38448315 DOI: 10.1016/j.ultrasmedbio.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/23/2024] [Accepted: 02/14/2024] [Indexed: 03/08/2024]
Abstract
OBJECTIVE The aim of this study was to develop and prospectively validate a prediction model for superficial lymphadenopathy differentiation using Sonazoid contrast-enhanced ultrasound (CEUS) combined with ultrasound (US) and clinical data. METHODS The training cohort comprised 260 retrospectively enrolled patients with 260 pathological lymph nodes imaged between January and December 2020. Two clinical US-CEUS models were created using multivariable logistic regression analysis and compared using receiver operating characteristic curve analysis: Model 1 included clinical and US characteristics; Model 2 included all confirmed predictors, including CEUS characteristics. Feature contributions were evaluated using the SHapley Additive exPlanations (SHAP) algorithm. Data from 172 patients were prospectively collected between January and May 2021 for model validation. RESULTS Age, tumor history, long-axis diameter of lymph node, blood flow distribution, echogenic hilus, and the mean postvascular phase intensity (MPI) were identified as independent predictors for malignant lymphadenopathy. The area under the curve (AUC), sensitivity, specificity, and accuracy of MPI alone was 0.858 (95% confidence interval [CI], 0.817-0.891), 86.47%, 74.55%, and 81.2%, respectively. Model 2 had an AUC of 0.919 (95% CI, 0.879-0.949) and good calibration in training and validation cohorts. The incorporation of MPI significantly enhanced diagnostic capability (p < 0.0001 and p = 0.002 for training and validation cohorts, respectively). Decision curve analysis indicated Model 2 as the superior diagnostic tool. SHAP analysis highlighted MPI as the most pivotal feature in the diagnostic process. CONCLUSION The employment of our straightforward prediction model has the potential to enhance clinical decision-making and mitigate the need for unwarranted biopsies.
Collapse
|
4
|
Application of artificial intelligence in pancreas endoscopic ultrasound imaging- A systematic review. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 250:108205. [PMID: 38703435 DOI: 10.1016/j.cmpb.2024.108205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 04/13/2024] [Accepted: 04/24/2024] [Indexed: 05/06/2024]
Abstract
The pancreas is a vital organ in digestive system which has significant health implications. It is imperative to evaluate and identify malignant pancreatic lesions promptly in light of the high mortality rate linked to such malignancies. Endoscopic Ultrasound (EUS) is a non-invasive precise technique to detect pancreas disorders, but it is highly operator dependent. Artificial intelligence (AI), including traditional machine learning (ML) and deep learning (DL) techniques can play a pivotal role to enhancing the performance of EUS regardless of operator. AI performs a critical function in the detection, classification, and segmentation of medical images. The utilization of AI-assisted systems has improved the accuracy and productivity of pancreatic analysis, including the detection of diverse pancreatic disorders (e.g., pancreatitis, masses, and cysts) as well as landmarks and parenchyma. This systematic review examines the rapidly developing domain of AI-assisted system in EUS of the pancreas. Its objective is to present a thorough study of the present research status and developments in this area. This paper explores the significant challenges of AI-assisted system in pancreas EUS imaging, highlights the potential of AI techniques in addressing these challenges, and suggests the scope for future research in domain of AI-assisted EUS systems.
Collapse
|
5
|
Contrast-enhanced US in Renal Transplant Complications: Overview and Imaging Features. Radiographics 2024; 44:e230182. [PMID: 38781089 DOI: 10.1148/rg.230182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2024]
Abstract
Renal transplant is the first-line treatment of end-stage renal disease. The increasing number of transplants performed every year has led to a larger population of transplant patients. Complications may arise during the perioperative and postoperative periods, and imaging plays a key role in this scenario. Contrast-enhanced US (CEUS) is a safe tool that adds additional value to US. Contrast agents are usually administered intravenously, but urinary tract anatomy and complications such as stenosis or leak can be studied using intracavitary administration of contrast agents. Assessment of the graft and iliac vessels with CEUS is particularly helpful in identifying vascular and parenchymal complications, such as arterial or venous thrombosis and stenosis, acute tubular injury, or cortical necrosis, which can lead to graft loss. Furthermore, infectious and malignant graft involvement can be accurately studied with CEUS, which can help in detection of renal abscesses and in the differentiation between benign and malignant disease. CEUS is also useful in interventional procedures, helping to guide percutaneous aspiration of collections with better delimitation of the graft boundaries and to guide renal graft biopsies by avoiding avascular areas. Potential postprocedural vascular complications, such as pseudoaneurysm, arteriovenous fistula, or active bleeding, are identified with CEUS. In addition, newer quantification tools such as CEUS perfusion are promising, but further studies are needed to approve its use for clinical purposes. ©RSNA, 2024 Supplemental material is available for this article.
Collapse
|
6
|
Quantitative analysis of contrast-enhanced ultrasound and superb microvascular imaging for the evaluation of disease activity in inflammatory bowel disease. Clin Hemorheol Microcirc 2024:CH242114. [PMID: 38788062 DOI: 10.3233/ch-242114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2024]
Abstract
OBJECTIVE To evaluate the effectiveness of conventional US (ultrasound), SMI (superb microvascular imaging), and CEUS (contrast-enhanced ultrasound) features for the assessment of the activity of inflammatory bowel disease. METHODS Conventional US, CEUS and SMI features of 76 patients were retrospectively analyzed. Patients were categorized into two groups: active group (n = 57) and inactive group (n = 19), with endoscopic results as reference standard. Results in the active group and inactive group were compared using an independent t-test, Mann-Whitney U test, chi-square test, and receiver operating characteristic curve (ROC) analysis. Cut-off values were determined using ROC analysis, and sensitivity and specificity were calculated. US quantitative and TIC-based quantitative parameters were analyzed, and each patient was scored based on the parameters that are statistically significant and immediately available in the clinic to evaluate the diagnostic ability of conventional US, SMI, and CEUS features for active IBD patients. RESULTS Qualitative parameters such as CEUS enhancement pattern I/II, LimbergIII/IV, and lost bowel stratification were reliable indicators of active patients. Quantitative parameters such as bowel thickness and VI of mSMI were reliable indicators of active patients. Patients scored based on these statistically significant parameters with a score ≥3, were highly suspected to be active patients. For TIC-based quantitative parameters, PE, WiAUC, WoAUC, WiWoAUC, WiR, WiPI, and WoR were statistically significant in the differentiation of active IBD from inactive IBD. CONCLUSIONS Conventional US, SMI, and CEUS features may help in the differentiation of active IBD from inactive IBD and have potential application value in the choice of treatment options.
Collapse
|
7
|
The Value of Contrast-Enhanced Ultrasound (CEUS) in the Evaluation of Central Lung Cancer with Obstructive Atelectasis. Diagnostics (Basel) 2024; 14:1051. [PMID: 38786349 PMCID: PMC11119496 DOI: 10.3390/diagnostics14101051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 05/03/2024] [Accepted: 05/14/2024] [Indexed: 05/25/2024] Open
Abstract
Purpose: To assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) alongside contrast-enhanced computed tomography (CECT) in evaluating central lung cancer (CLC). Materials and Methods: From 2006 to 2022, 54 patients with CLC and obstructive atelectasis (OAT) underwent standardized examinations using CEUS in addition to CECT. The ability to differentiate CLC from atelectatic tissue in CECT and CEUS was categorized as distinguishable or indistinguishable. In CEUS, in distinguishable cases, the order of enhancement (time to enhancement) (OE; categorized as either an early pulmonary arterial [PA] pattern or a delayed bronchial arterial [BA] pattern of enhancement), the extent of enhancement (EE; marked or reduced), the homogeneity of enhancement (HE; homogeneous or inhomogeneous), and the decrease in enhancement (DE; rapid washout [<120 s] or late washout [≥120 s]) were evaluated. Results: The additional use of CEUS improved the diagnostic capability of CECT from 75.9% to 92.6% in differentiating a CLC from atelectatic tissue. The majority of CLC cases exhibited a BA pattern of enhancement (89.6%), an isoechoic reduced enhancement (91.7%), and a homogeneous enhancement (91.7%). Rapid DE was observed in 79.2% of cases. Conclusions: In cases of suspected CLC with obstructive atelectasis, the application of CEUS can be helpful in differentiating tumor from atelectatic tissue and in evaluating CLC.
Collapse
|
8
|
Diagnostic Performance of Contrast-Enhanced Ultrasound in Testicular Space-Occupying Lesions: A Systematic Review and Meta-analysis. Acad Radiol 2024:S1076-6332(24)00239-3. [PMID: 38714430 DOI: 10.1016/j.acra.2024.04.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 04/16/2024] [Accepted: 04/17/2024] [Indexed: 05/09/2024]
Abstract
PURPOSE Contrast-enhanced ultrasound (CEUS) has been increasingly used for the diagnostic identification of neoplasms due to its ability to visualize the microvascularization of lesions. In the study of testicular abnormalities, the appropriate use of CEUS can improve the diagnostic accuracy of conventional gray-scale ultrasound and color Doppler ultrasound (CDUS). The purpose of this study is to comprehensively evaluate the diagnostic performance of CEUS in testicular space-occupying lesions. METHODS A comprehensive search of PubMed, Embase, Cochrane Library, and Web of Science databases was conducted from the inception of each database to November 16, 2022 for relevant studies. The required data were extracted, and the methodological quality of the studies was assessed using the QUADAS-2 tool. The diagnostic value of CEUS was assessed by calculating the combined sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio, and a summary receiver operating characteristic (SROC) curve was used to conduct this meta-analysis. RESULTS A total of six studies with 354 testicular space-occupying lesions were included in the analysis. The results showed that CEUS could provide additional useful information for the diagnosis of testicular space-occupying lesions, with a sensitivity of 0.92 (95% CI:0.82, 0.97), specificity of 0.91 (95% CI:0.80, 0.96), diagnostic odds ratio of 114 (95% CI:25, 528), respectively, and an overall diagnostic accuracy expressed as area under the SROC curve (AUC) of 0.97 (95% CI:0.95-0.98). Significant heterogeneity was seen in the sensitivity with I2 = 82.53% (95% CI:69.44-95.61). Subgroup analysis revealed that the proportion of infertile patients selected may be the source of heterogeneity. CONCLUSION CEUS can be used to diagnose testicular space-occupying lesions more accurately and improve diagnostic accuracy when the conventional US cannot accurately differentiate the type of lesion. In particular, CEUS should be recommended for the identification of microscopic lesions so that physicians can provide patients with more appropriate interventions to avoid unnecessary orchiectomy.
Collapse
|
9
|
The Diagnosis and Treatment of Acute Cholecystitis: A Comprehensive Narrative Review for a Practical Approach. J Clin Med 2024; 13:2695. [PMID: 38731224 PMCID: PMC11084823 DOI: 10.3390/jcm13092695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 04/17/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024] Open
Abstract
Acute cholecystitis (AC), generally associated with the presence of gallstones, is a relatively frequent disease that can lead to serious complications. For these reasons, AC warrants prompt clinical diagnosis and management. There is general agreement in terms of considering early laparoscopic cholecystectomy (ELC) to be the best treatment for AC. The optimal timeframe to perform ELC is within 72 h from diagnosis, with a possible extension of up to 7-10 days from symptom onset. In the first hours or days after hospital admission, before an ELC procedure, the patient's medical management comprises fasting, intravenous fluid infusion, antimicrobial therapy, and possible administration of analgesics. Additionally, concomitant conditions such as choledocholithiasis, cholangitis, biliary pancreatitis, or systemic complications must be recognized and adequately treated. The importance of ELC is related to the frequent recurrence of symptoms and complications of gallstone disease in the interval period between the onset of AC and surgical intervention. In patients who are not eligible for ELC, it is suggested to delay surgery at least 6 weeks after the clinical presentation. Critically ill patients, who are unfit for surgery, may require rescue treatments, such as percutaneous or endoscopic gallbladder drainage (GBD). A particular treatment approach should be applied to special populations such as pregnant women, cirrhotic, and elderly patients. In this review, we provide a practical diagnostic and therapeutic approach to AC, even in specific clinical situations, based on evidence from the literature.
Collapse
|
10
|
Basic Principles and Role of Endoscopic Ultrasound in Diagnosis and Differentiation of Pancreatic Cancer from Other Pancreatic Lesions: A Comprehensive Review of Endoscopic Ultrasound for Pancreatic Cancer. J Clin Med 2024; 13:2599. [PMID: 38731128 PMCID: PMC11084399 DOI: 10.3390/jcm13092599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 04/17/2024] [Accepted: 04/21/2024] [Indexed: 05/13/2024] Open
Abstract
Pancreatic cancer is one of the leading causes of cancer-related deaths worldwide. Pancreatic lesions consist of both neoplastic and non-neoplastic lesions and often pose a diagnostic and therapeutic challenge due to similar clinical and radiological features. In recent years, pancreatic lesions have been discovered more frequently as incidental findings due to the increased utilization and widespread availability of abdominal cross-sectional imaging. Therefore, it becomes imperative to establish an early and appropriate diagnosis with meticulous differentiation in an attempt to balance unnecessary treatment of benign pancreatic lesions and missing the opportunity for early intervention in malignant lesions. Endoscopic ultrasound (EUS) has become an important diagnostic modality for the identification and risk stratification of pancreatic lesions due to its ability to provide detailed imaging and acquisition of tissue samples for analysis with the help of fine-needle aspiration/biopsy. The recent development of EUS-based technology, including contrast-enhanced endoscopic ultrasound, real-time elastography-endoscopic ultrasound, miniature probe ultrasound, confocal laser endomicroscopy, and the application of artificial intelligence has significantly augmented the diagnostic accuracy of EUS as it enables better evaluation of the number, location, dimension, wall thickness, and contents of these lesions. This article provides a comprehensive overview of the role of the different types of EUS available for the diagnosis and differentiation of pancreatic cancer from other pancreatic lesions while discussing their key strengths and important limitations.
Collapse
|
11
|
Prospects of perfusion contrast-enhanced ultrasound (CE-US) in diagnosing axillary lymph node metastases in breast cancer: a comparison with lymphatic CE-US. J Med Ultrason (2001) 2024:10.1007/s10396-024-01444-w. [PMID: 38642268 DOI: 10.1007/s10396-024-01444-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 02/18/2024] [Indexed: 04/22/2024]
Abstract
Accurate diagnosis of lymph node (LN) metastasis is vital for prognosis and treatment in patients with breast cancer. Imaging 1modalities such as ultrasound (US), MRI, CT, and 18F-FDG PET/CT are used for preoperative assessment. While conventional US is commonly recommended due to its resolution and sensitivity, it has limitations such as operator subjectivity and difficulty detecting small metastases. This review shows the microanatomy of axillary LNs to enhance accurate diagnosis and the characteristics of contrast-enhanced US (CE-US), which utilizes intravascular microbubble contrast agents, making it ideal for vascular imaging. A significant focus of this review is on distinguishing between two types of CE-US techniques for axillary LN evaluation: perfusion CE-US and lymphatic CE-US. Perfusion CE-US is used to assess LN metastasis via transvenous contrast agent administration, while lymphatic CE-US is used to identify sentinel LNs and diagnose LN metastasis through percutaneous contrast agent administration. This review also highlights the need for future research to clarify the distinction between studies involving "apparently enlarged LNs" and "clinical node-negative" cases in perfusion CE-US research. Such research standardization is essential to ensure accurate diagnostic performance in various clinical studies. Future studies should aim to standardize CE-US methods for improved LN metastasis diagnosis, not only in breast cancer but also across various malignancies.
Collapse
|
12
|
Enhancing the Extent of Resection in Glioma Surgery Through the Integration of Intraoperative Contrast-Enhanced Ultrasound and Fluorescein Sodium. World Neurosurg 2024:S1878-8750(24)00589-8. [PMID: 38608808 DOI: 10.1016/j.wneu.2024.04.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/03/2024] [Accepted: 04/04/2024] [Indexed: 04/14/2024]
Abstract
OBJECTIVE Due to the infiltrative nature and high local recurrence of gliomas, particularly high-grade gliomas, gross total resection (GTR) of a tumor is the first critical step in treatment. This study aimed to determine whether the integration of intraoperative contrast-enhanced ultrasound (CEUS) and fluorescein sodium can improve the identification of tumor boundaries and residuals, and increasethe extent of resection (EOR) to better protect neurological function. METHODS We retrospectively analysed clinical data from 87 glioma surgeries and categorised the patients into 3 groups: CEUS plus fluorescein sodium, fluorescein sodium alone and microsurgery alone. RESULTS In terms of EOR, GTR was achieved in 22 (91.7%) patients in the CEUS plus fluorescein sodium group, which was significantly higher than that in other groups. In the subgroup analysis of tumors with lobulated or satellite lesions and WHO grade III or IV gliomas, CEUS plus fluorescein sodium group showed the highest GTR (86.7% and 88.9% respectively) among the groups. Logistic regression analysis of factors that may affect the GTR of tumors showed that the functional areas involvement and the presence of lobulated or satellite lesions were risk factors, whereas CEUS plus fluorescein sodium group was a protective factor. However, CEUS plus fluorescein sodium group had the longest surgery time. CONCLUSIONS Intraoperative CEUS with fluorescein sodium is a real-time, straightforward, safe, and effective approach to perform surgical resection of gliomas. This approach assists surgeons in identifying tumor boundaries, residual tumors, and normal brain parenchyma, which increases the EOR.
Collapse
|
13
|
The value of contrast-enhanced ultrasound in percutaneous biopsy of retroperitoneal masses. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2024. [PMID: 38588693 DOI: 10.1055/a-2282-2353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/10/2024]
Abstract
PURPOSE To evaluate the diagnostic yield of contrast-enhanced ultrasound (CEUS)-guided biopsy of retroperitoneal masses (RMs). MATERIALS AND METHODS Between 2006 and 2023, 87 patients presented at our US center for biopsy of an RM. In all biopsies, CEUS was performed prior to the intervention. The technical success rate of biopsy, the presence of diagnostic tissue in solid tumor biopsy samples, the accuracy of the biopsy and the occurrence of post-interventional complications were evaluated. RESULTS A US-guided biopsy could be conducted in 84/87 cases (96.6%). In 3/87 cases (3.4%), US-guided biopsy was impossible because the planned needle path was obstructed by vital structures. Of 84 lesions, 80 (95.2%) were solid lesions, and 4 (4.8%) were lesions containing fluid. In all solid tumors, 80/80 (100%), diagnostic vital tissue was successfully obtained. CEUS-guided biopsy showed a sensitivity of 93.2%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 72.2%, and a diagnostic accuracy of 94.2% for the differentiation between malignant and benign RMs. In one of the 84 cases (1.2%), there was a complication of postinterventional abdominal pain. CONCLUSION Percutaneous CEUS-guided biopsy is a safe procedure with a high diagnostic yield and a low complication rate.
Collapse
|
14
|
Applying machine-learning models to differentiate benign and malignant thyroid nodules classified as C-TIRADS 4 based on 2D-ultrasound combined with five contrast-enhanced ultrasound key frames. Front Endocrinol (Lausanne) 2024; 15:1299686. [PMID: 38633756 PMCID: PMC11021584 DOI: 10.3389/fendo.2024.1299686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 03/21/2024] [Indexed: 04/19/2024] Open
Abstract
Objectives To apply machine learning to extract radiomics features from thyroid two-dimensional ultrasound (2D-US) combined with contrast-enhanced ultrasound (CEUS) images to classify and predict benign and malignant thyroid nodules, classified according to the Chinese version of the thyroid imaging reporting and data system (C-TIRADS) as category 4. Materials and methods This retrospective study included 313 pathologically diagnosed thyroid nodules (203 malignant and 110 benign). Two 2D-US images and five CEUS key frames ("2nd second after the arrival time" frame, "time to peak" frame, "2nd second after peak" frame, "first-flash" frame, and "second-flash" frame) were selected to manually label the region of interest using the "Labelme" tool. A total of 7 images of each nodule and their annotates were imported into the Darwin Research Platform for radiomics analysis. The datasets were randomly split into training and test cohorts in a 9:1 ratio. Six classifiers, namely, support vector machine, logistic regression, decision tree, random forest (RF), gradient boosting decision tree and extreme gradient boosting, were used to construct and test the models. Performance was evaluated using a receiver operating characteristic curve analysis. The area under the curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy (ACC), and F1-score were calculated. One junior radiologist and one senior radiologist reviewed the 2D-US image and CEUS videos of each nodule and made a diagnosis. We then compared their AUC and ACC with those of our best model. Results The AUC of the diagnosis of US, CEUS and US combined CEUS by junior radiologist and senior radiologist were 0.755, 0.750, 0.784, 0.800, 0.873, 0.890, respectively. The RF classifier performed better than the other five, with an AUC of 1 for the training cohort and 0.94 (95% confidence interval 0.88-1) for the test cohort. The sensitivity, specificity, accuracy, PPV, NPV, and F1-score of the RF model in the test cohort were 0.82, 0.93, 0.90, 0.85, 0.92, and 0.84, respectively. The RF model with 2D-US combined with CEUS key frames achieved equivalent performance as the senior radiologist (AUC: 0.94 vs. 0.92, P = 0.798; ACC: 0.90 vs. 0.92) and outperformed the junior radiologist (AUC: 0.94 vs. 0.80, P = 0.039, ACC: 0.90 vs. 0.81) in the test cohort. Conclusions Our model, based on 2D-US and CEUS key frames radiomics features, had good diagnostic efficacy for thyroid nodules, which are classified as C-TIRADS 4. It shows promising potential in assisting less experienced junior radiologists.
Collapse
|
15
|
Current Developments and Role of Intestinal Ultrasound including the Advent of AI. Diagnostics (Basel) 2024; 14:759. [PMID: 38611672 PMCID: PMC11011653 DOI: 10.3390/diagnostics14070759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 03/18/2024] [Accepted: 03/29/2024] [Indexed: 04/14/2024] Open
Abstract
Intestinal ultrasound is a non-invasive, safe, and cost-effective technique to study the small and large intestines. In addition to conventional B-mode and color doppler imaging, new US tools have been developed in more recent years that provide auxiliary data on many GI conditions, improving the diagnosis and assessment of relevant outcomes. We have reviewed the more recent literature (from 2010 onwards) on auxiliary tools in bowel ultrasound such as elastography techniques, CEUS, SICUS, and the potential contribution by artificial intelligence (AI) to overcome current intestinal ultrasound limitations. For this scoping review, we performed an extensive literature search on PubMed and EMBASE to identify studies published until December 2023 and investigating the application of elastography techniques, CEUS, SICUS, and AI in the ultrasonographic assessment of the small and large intestines. Multiparametric intestinal ultrasound shows promising capabilities in Crohn's disease, while less is known about the role in ulcerative colitis. Despite some evidence, the CEUS role as a point-of-care examination tool for rare conditions such as intestinal GvHD and ischemic small bowel disease seems promising, possibly avoiding the need to perform further cross-sectional imaging. The use of AI in intestinal ultrasound is still anecdotical and limited to acute appendicitis.
Collapse
|
16
|
Contrast-enhanced ultrasound combined with elastic imaging for predicting the efficacy of concurrent chemoradiotherapy in cervical cancer: a feasibility study. Front Oncol 2024; 14:1301900. [PMID: 38634056 PMCID: PMC11021703 DOI: 10.3389/fonc.2024.1301900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 03/18/2024] [Indexed: 04/19/2024] Open
Abstract
Objective Contrast-enhanced ultrasound (CEUS) and elastography are of great value in the diagnosis of cervical cancer (CC). However, there is limited research on the role of contrast-enhanced ultrasound combined with elastography in predicting concurrent chemoradiotherapy and disease progression for cervical cancer. The purpose of this study was to evaluate the feasibility of contrast-enhanced ultrasound combined with elastography and tumor prognosis. Methods MRI was performed on 98 patients with cervical cancer before and after treatment. Before, during, and 1 week after the treatment, contrast-enhanced ultrasound and elastography were conducted, and the alterations of ultrasound-related parameters at each time point of the treatment were compared. The correlation between contrast-enhanced ultrasound combined with elastic imaging and oncological outcome was assessed. Results There was no notable difference in overall clinical data between the complete remission (CR) group and the partial remission (PR) group (P>0.05). Before treatment, there were no statistically significant differences in elasticity score, time to peak (TTP), and peak intensity (PI) between the CR group and the PR group. However, there were no statistical differences in elastic strain ratio (SR) and area under the curve (AUC) before and after treatment between the CR group and the PR group, and there were also no statistical differences in the elastic strain ratio (SR) and area under the curve (AUC) of contrast-enhanced ultrasound parameters between the CR group and the PR group before and during treatment. There was a statistically significant difference after treatment (P<0.05).At present, the follow-up of patients is about 1 year, 7 patients were excluded due to loss to follow-up, and 91 patients were included in the follow-up study. Through the review of the cases and combined with MRI (version RECIST1.1) and serology and other related examinations, if the patient has a new lesion or the lesion is larger than before, the tumor marker Squamous cell carcinoma antigen (SCC-Ag) is significantly increased twice in a row, and the patient is divided into progressive disease (PD). Those who did not see significant changes were divided into stable disease (SD) group. The relationship between clinical characteristics, ultrasound parameters and disease progression in 91 patients was compared. There was no significant difference in age and clinical stage between the two groups (P>0.05), but there was a significant difference in the elevation of tumor marker squamous cell carcinoma antigen (SCC-Ag) between the two groups (P<0.05).With the growth of tumors, TTP decreased, elasticity score and PI increased, and the difference was statistically significant (P<0.05). The AUC of SCC-Ag was 0.655, the sensitivity was 85.3%, and the specificity was 45.6%.The AUC, sensitivity and specificity of ultrasound parameters combined with SCC-Ag predicted disease progression was 0.959, 91.2% and 94.8%. Conclusions Using contrast-enhanced ultrasound and elastography to predict the efficacy and disease progression of concurrent chemoradiotherapy is feasible. In addition, the combination of SCC-Ag with contrast-enhanced ultrasound and elastography can further enhance the efficiency of predicting disease progression.
Collapse
|
17
|
Reliability of Ultrasound Shear Wave Elastography for Evaluating Psoas Major and Quadratus Lumborum Stiffness: Gender and Physical Activity Effects. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:564-570. [PMID: 38272743 DOI: 10.1016/j.ultrasmedbio.2023.12.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 12/04/2023] [Accepted: 12/22/2023] [Indexed: 01/27/2024]
Abstract
OBJECTIVE We aimed to assess the reliability of quantifying psoas major (PM) and quadratus lumborum (QL) stiffness with ultrasound shear wave elastography (SWE), and to explore the effects of gender and physical activity on muscle stiffness. METHODS Fifty-two healthy participants (18-32 y) were recruited. To determine reliability, 29 of them underwent repeated SWE measurements of PM and QL stiffness by an operator on the same day. The intra-class correlation coefficients (ICC3,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence interval (MDC95) were calculated. The rest participants underwent a single measurement. Two-way MANCOVA was conducted for the effects of gender and physical activity on muscle stiffness. RESULTS The observed reliability for PM (ICC3,1 = 0.89-0.92) and QL (ICC3,1 = 0.79-0.82) were good-to-excellent and good, respectively. The SEM (kPa) was 0.79-1.03 and 1.23-1.28, and the MDC95 (kPa) was 2.20-2.85 and 3.41-3.56 for PM and QL, respectively. After BMI adjustment, both gender (PM: F = 10.15, p = 0.003; QL: F = 18.07, p < 0.001) and activity level (PM: F = 5.90, p = 0.005; QL: F = 6.33, p = 0.004) influenced muscle stiffness. The female and inactive groups exhibited higher stiffness in both muscles. CONCLUSION SWE is reliable for quantifying the stiffness of PM and QL. Female and physical inactivity may elevate PM and QL stiffness, underscoring the importance of accounting for these factors in muscle stiffness investigations. Larger prospective studies are needed to further elucidate their effects.
Collapse
|
18
|
Diagnostic accuracy of qualitative and quantitative magnetic resonance imaging-guided contrast-enhanced ultrasound (MRI-guided CEUS) for the detection of prostate cancer: a prospective and multicenter study. LA RADIOLOGIA MEDICA 2024; 129:585-597. [PMID: 38512615 DOI: 10.1007/s11547-024-01758-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 01/03/2024] [Indexed: 03/23/2024]
Abstract
PURPOSE To evaluate the diagnostic value of MRI-guided contrast-enhanced ultrasound (CEUS) for prostate cancer (PCa) diagnosis, and characteristics of PCa in qualitative and quantitative CEUS. MATERIAL AND METHODS This prospective and multicenter study included 250 patients (133 in the training cohort, 57 in the validation cohort and 60 in the test cohort) who underwent MRI, MRI-guided CEUS and prostate biopsy between March 2021 and February 2023. MRI interpretation, qualitative and quantitative CEUS analysis were conducted. Multitree extreme gradient boosting (XGBoost) machine learning-based models were applied to select the eight most important quantitative parameters. Univariate and multivariate logistic regression models were constructed to select independent predictors of PCa. Diagnostic value was determined for MRI, qualitative and quantitative CEUS using the area under receiver operating characteristic curve (AUC). RESULTS The performance of quantitative CEUS was superior to that of the qualitative CEUS and MRI in predicting PCa. The AUC was 0.779 (95%CI 0.70-0.849), 0.756 (95%CI 0.638-0.874) and 0.759 (95%CI 0.638-0.879) of qualitative CEUS, and 0.885 (95%CI 0.831-0.940), 0.802 (95%CI 0.684-0.919) and 0.824 (95%CI 0.713-0.936) of quantitative CEUS in training, validation and test cohort, respectively. Compared with quantitative CEUS, MRI achieved less well performance for AUC 0.811 (95%CI 0.741-0.882, p = 0.099), 0.748 (95%CI 0.628-0.868, p = 0.539) and 0.737 (95%CI 0.602-0.873, p = 0.029), respectively. Moreover, the highest specificity of 80.6% was obtained by quantitative CEUS. CONCLUSION We developed a reliable method of MRI-guided CEUS that demonstrated enhanced performance compared to MRI. The qualitative and quantitative CEUS characteristics will contribute to improved diagnosis of PCa.
Collapse
|
19
|
Predictive value of contrast-enhanced ultrasonography and ultrasound elastography for management of BI-RADS category 4 nonpalpable breast masses. Eur J Radiol 2024; 173:111391. [PMID: 38422608 DOI: 10.1016/j.ejrad.2024.111391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 02/07/2024] [Accepted: 02/21/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE The objective of this study was to investigate the independent risk factors and associated predictive values of contrast-enhanced ultrasound (CEUS), shear wave elastography (SWE), and strain elastography (SE) for high-risk lesions (HRL) and malignant tumors (MT) among nonpalpable breast masses classified as BI-RADS category 4 on conventional ultrasound. METHODS This prospective study involved consecutively admitted patients with breast tumors from January 2018, aiming to explore the management of BI-RADS category 4 breast tumors using CEUS and elastography. We conducted a retrospective review of patient data, focusing on those with a history of a nonpalpable mass as the primary complaint. Pathologic findings after surgical resection served as the gold standard. The CEUS arterial-phase indices were analyzed using contrast agent arrival-time parametric imaging processing mode, while quantitative and qualitative indices were examined on ES images. Independent risk factors were identified through binary logistic regression multifactorial analysis. The predictive efficacy of different modalities was compared using a receiver operating characteristics curve. Subsequently, a nomogram for predicting the risk of HRL/MT was established based on a multifactorial logistic regression model. RESULTS A total of 146 breast masses from 146 patients were included, comprising 80 benign tumors, 12 HRLs, and 54 MTs based on the final pathology. There was no significant difference in pathologic size between the benign and HRL/MT groups [8.00(6.25,10.00) vs. 9.00(6.00,10.00), P = 0.506]. The diagnostic efficacy of US plus CEUS exceeded that of US plus SWE/SE for BI-RADS 4 nonpalpable masses, with an AUC of 0.954 compared to 0.798/0.741 (P < 0.001). Further stratified analysis revealed a more pronounced improvement for reclassification of BI-RADS 4a masses (AUC: 0.943 vs. 0.762/0.675, P < 0.001) than BI-RADS 4b (AUC:0.950 vs. 0.885/0.796, P>0.05) with the assistance of CEUS than SWE/SE. Employing downgrade CEUS strategies resulted in negative predictive values ranging from 95.2 % to 100.0 % for BI-RADS 4a and 4b masses. Conversely, using upgrade nomogram strategies, which included the independent predictive risk factors of irregular enhanced shape, poor defined enhanced margin, earlier enhanced time, increased surrounding vessels, and presence of contrast agent retention, the diagnostic performance achieved an AUC of 0.947 with good calibration. CONCLUSION After investigating the potential of CEUS and ES in improving risk assessment and diagnostic accuracy for nonpalpable BI-RADS category 4 breast masses, it is evident that CEUS has a more significant impact on enhancing classification compared to ES, particularly for BI-RADS 4a subgroup masses. This finding suggests that CEUS may offer greater benefits in improving risk assessment and diagnostic accuracy for this specific subgroup of breast masses.
Collapse
|
20
|
Deep learning using contrast-enhanced ultrasound images to predict the nuclear grade of clear cell renal cell carcinoma. World J Urol 2024; 42:184. [PMID: 38512539 DOI: 10.1007/s00345-024-04889-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Accepted: 02/12/2024] [Indexed: 03/23/2024] Open
Abstract
PURPOSE To assess the effectiveness of a deep learning model using contrastenhanced ultrasound (CEUS) images in distinguishing between low-grade (grade I and II) and high-grade (grade III and IV) clear cell renal cell carcinoma (ccRCC). METHODS A retrospective study was conducted using CEUS images of 177 Fuhrmangraded ccRCCs (93 low-grade and 84 high-grade) from May 2017 to December 2020. A total of 6412 CEUS images were captured from the videos and normalized for subsequent analysis. A deep learning model using the RepVGG architecture was proposed to differentiate between low-grade and high-grade ccRCC. The model's performance was evaluated based on sensitivity, specificity, positive predictive value, negative predictive value and area under the receiver operating characteristic curve (AUC). Class activation mapping (CAM) was used to visualize the specific areas that contribute to the model's predictions. RESULTS For discriminating high-grade ccRCC from low-grade, the deep learning model achieved a sensitivity of 74.8%, specificity of 79.1%, accuracy of 77.0%, and an AUC of 0.852 in the test set. CONCLUSION The deep learning model based on CEUS images can accurately differentiate between low-grade and high-grade ccRCC in a non-invasive manner.
Collapse
|
21
|
The imaging features of ectopic spleen: which modality is more consistent? A cases series report and literature reviews. Front Oncol 2024; 14:1310394. [PMID: 38529386 PMCID: PMC10961413 DOI: 10.3389/fonc.2024.1310394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/20/2024] [Indexed: 03/27/2024] Open
Abstract
Ectopic spleen (ES) is a rare condition. It is difficult to diagnose with conventional imaging modalities. In this case series, we presented the imaging features of three misdiagnosed ES cases in our hospital and previously reported cases to compare the consistency of enhancement patterns among different imaging modalities with varied phases. Finally, 22 cases were reviewed. We determined that variable arterial phase enhancement and persistent enhancement throughout the portal and delayed phases are present in contrast-enhanced ultrasound (CEUS) imaging of the ES and found the arterial phase of CEUS had the highest consistency compared with computerized tomography (CT) and magnetic resonance imaging (MRI).
Collapse
|
22
|
Diagnosis of benign and malignant peripheral lung lesions based on a feature model constructed by the random forest algorithm for grayscale and contrast-enhanced ultrasound. Front Oncol 2024; 14:1352028. [PMID: 38529369 PMCID: PMC10961397 DOI: 10.3389/fonc.2024.1352028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/26/2024] [Indexed: 03/27/2024] Open
Abstract
Rationale and objectives To construct a predictive model for benign and malignant peripheral pulmonary lesions (PPLs) using a random forest algorithm based on grayscale ultrasound and ultrasound contrast, and to evaluate its diagnostic value. Materials and methods We selected 254 patients with PPLs detected using chest lung computed tomography between October 2021 and July 2023, including 161 malignant and 93 benign lesions. Relevant variables for judging benign and malignant PPLs were screened using logistic regression analysis. A model was constructed using the random forest algorithm, and the test set was verified. Correlations between these relevant variables and the diagnosis of benign and malignant PPLs were evaluated. Results Age, lesion shape, size, angle between the lesion border and chest wall, boundary clarity, edge regularity, air bronchogram, vascular signs, enhancement patterns, enhancement intensity, homogeneity of enhancement, number of non-enhancing regions, non-enhancing region type, arrival time (AT) of the lesion, lesion-lung AT difference, AT difference ratio, and time to peak were the relevant variables for judging benign and malignant PPLs. Consequently, a model and receiver operating characteristic curve were constructed with an AUC of 0.92 and an accuracy of 88.2%. The test set results showed that the model had good predictive ability. The index with the highest correlation for judging benign and malignant PPLs was the AT difference ratio. Other important factors were lesion size, patient age, and lesion morphology. Conclusion The random forest algorithm model constructed based on clinical data and ultrasound imaging features has clinical application value for predicting benign and malignant PPLs.
Collapse
|
23
|
A Comparative Study of Two Radiomics-Based Blood Flow Modes with Thyroid Imaging Reporting and Data System in Predicting Malignancy of Thyroid Nodules and Reducing Unnecessary Fine-Needle Aspiration Rate. Acad Radiol 2024:S1076-6332(24)00077-1. [PMID: 38453602 DOI: 10.1016/j.acra.2024.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 02/02/2024] [Accepted: 02/04/2024] [Indexed: 03/09/2024]
Abstract
RATIONALE AND OBJECTIVES We aimed to compare superb microvascular imaging (SMI)-based radiomics methods, and contrast-enhanced ultrasound (CEUS)-based radiomics methods to the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) for classifying thyroid nodules (TNs) and reducing unnecessary fine-needle aspiration biopsy (FNAB) rate. MATERIALS AND METHODS This retrospective study enrolled a dataset of 472 pathologically confirmed TNs. Radiomics characteristics were extracted from B-mode ultrasound (BMUS), SMI, and CEUS images, respectively. After eliminating redundant features, four radiomics scores (Rad-scores) were constructed. Using multivariable logistic regression analysis, four radiomics prediction models incorporating Rad-score and corresponding US features were constructed and validated in terms of discrimination, calibration, decision curve analysis, and unnecessary FNAB rate. RESULTS The diagnostic performance of the BMUS + SMI radiomics method was better than ACR TI-RADS (area under the curve [AUC]: 0.875 vs. 0.689 for the training cohort, 0.879 vs. 0.728 for the validation cohort) (P < 0.05), and comparable with BMUS + CEUS radiomics method (AUC: 0.875 vs. 0.878 for the training cohort, 0.879 vs. 0.865 for the validation cohort) (P > 0.05). Decision curve analysis showed that the BMUS+SMI radiomics method could achieve higher net benefits than the BMUS radiomics method and ACR TI-RADS when the threshold probability was between 0.13 and 0.88 in the entire cohort. When applying the BMUS+SMI radiomics method, the unnecessary FNAB rate reduced from 43.4% to 13.9% in the training cohort and from 45.6% to 18.0% in the validation cohorts in comparison to ACR TI-RADS. CONCLUSION The dual-modal SMI-based radiomics method is convenient and economical and can be an alternative to the dual-modal CEUS-based radiomics method in helping radiologists select the optimal clinical strategy for TN management.
Collapse
|
24
|
Conventional and contrast-enhanced ultrasound in the differential diagnosis of recurrent dermatofibrosarcoma protuberans and postoperative scar. BMC Cancer 2024; 24:285. [PMID: 38438997 PMCID: PMC10910735 DOI: 10.1186/s12885-024-11991-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 02/11/2024] [Indexed: 03/06/2024] Open
Abstract
BACKGROUND Dermatofibrosarcoma protuberans (DFSP) has a high recurrence rate after resection. Because of the lack of specific manifestations, recurrent DFSP is easily misdiagnosed as post-resection scar. A few series have reported ultrasound findings of recurrent DFSP; moreover, the usefulness of contrast-enhanced ultrasound in differentiating recurrent DFSP has not been studied. OBJECTIVE We investigated conventional and contrast-enhanced ultrasound in the differential diagnosis of recurrent DFSP and post-resection scar. METHODS We retrospectively evaluated the findings of conventional and contrast-enhanced ultrasound in 34 cases of recurrent DFSP and 38 postoperative scars examined between January 2018 and December 2022. RESULTS The depth and vascular density of recurrent DFSP were greater than those of postoperative scars (P < 0.05). On gray-scale ultrasound, recurrent DFSP lesions were more commonly irregular, heterogeneous, and hypoechoic, with finger-like projections and ill-defined borders. Postoperative scar was more likely to appear as hypoechoic and homogeneous with well-defined borders (P < 0.05). On color Doppler ultrasound, recurrent DFSP was more likely to feature rich arterial and venous blood flow, and postoperative scar was more likely to display poor blood flow (P < 0.05). On contrast-enhanced ultrasound, recurrent DFSP was more likely to feature heterogeneous hyper-enhancement, and postoperative scar was more likely to display homogeneous iso-enhancement (P < 0.05). Recurrent DFSP presented a higher peak and sharpness than postoperative scar (P < 0.05). CONCLUSION Conventional and contrast-enhanced ultrasound produced distinct features of recurrent DFSP and post-resection scar, which could improve the accuracy of differential diagnosis.
Collapse
|
25
|
Augmentation of tumour perfusion by ultrasound and microbubbles: A preclinical study. ULTRASONICS 2024; 138:107219. [PMID: 38104380 DOI: 10.1016/j.ultras.2023.107219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 12/05/2023] [Accepted: 12/09/2023] [Indexed: 12/19/2023]
Abstract
BACKGROUND Hypoperfusion and the resulting hypoxia in solid tumours are critical causes of treatment resistance. Ultrasound-stimulated microbubbles (USMB) enhance tumour perfusion in a mechanism named the "sononeoperfusion" effect, which may relieve tumour hypoperfusion and hypoxia. The aim of this study was to determine the optimal mechanical index (MI) and therapeutic ultrasound exposure time for the sononeoperfusion effect and preliminarily explore the mechanism of sononeoperfusion and its effect on tumours. METHODS A total of 155 mice bearing MC38 tumours were included in this study. A modified diagnostic ultrasound and microbubbles (Zhifuxian) was used for USMB treatment. Tumour perfusion was evaluated by contrast-enhanced ultrasound (CEUS) and Hoechst 33342. The therapeutic pulse was operated with MIs of 0.1 to 0.5. The ultrasound exposure time was set from 150 s to 600 s. Endothelial nitric oxide synthase (eNOS) inhibition and NO, ATP, and phospho-eNOS (p-eNOS) detection were performed to explore the mechanisms of sononeoperfusion. Hypoxia-inducible factor-1α (HIF-1α) and tumour oxygen partial pressure (pO2) represent hypoxic tumour conditions. RESULTS Tumour perfusion was increased after USMB treatment at MIs of 0.1-0.4 and ultrasound exposure times of 150 s to 600 s, with optimal augmentation achieved at an MI of 0.3 and ultrasound exposure time of 450 s. The mean fluorescence intensity of Hoechst 33342 after USMB treatment was stronger than that of the control group. Biochemical assays showed a significant increase in ATP, p-eNOS and NO after USMB treatment. PO2 in tumour tissue increased significantly after USMB treatment and was maintained for more than 20 min. CONCLUSIONS The best sononeoperfusion effect was obtained with an MI of 0.3 and an ultrasound exposure time of 450 s. The effect is most likely related to NO and ATP increases. The sononeoperfusion effect might be a novel way to ameliorate tumour hypoperfusion and hypoxia.
Collapse
|
26
|
Predictive nomogram using multimodal ultrasonographic features for axillary lymph node metastasis in early‑stage invasive breast cancer. Oncol Lett 2024; 27:95. [PMID: 38288042 PMCID: PMC10823315 DOI: 10.3892/ol.2024.14228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 12/19/2023] [Indexed: 01/31/2024] Open
Abstract
Axillary lymph node (ALN) status is a key prognostic factor in patients with early-stage invasive breast cancer (IBC). The present study aimed to develop and validate a nomogram based on multimodal ultrasonographic (MMUS) features for early prediction of axillary lymph node metastasis (ALNM). A total of 342 patients with early-stage IBC (240 in the training cohort and 102 in the validation cohort) who underwent preoperative conventional ultrasound (US), strain elastography, shear wave elastography and contrast-enhanced US examination were included between August 2021 and March 2022. Pathological ALN status was used as the reference standard. The clinicopathological factors and MMUS features were analyzed with uni- and multivariate logistic regression to construct a clinicopathological and conventional US model and a MMUS-based nomogram. The MMUS nomogram was validated with respect to discrimination, calibration, reclassification and clinical usefulness. US features of tumor size, echogenicity, stiff rim sign, perfusion defect, radial vessel and US Breast Imaging Reporting and Data System category 5 were independent risk predictors for ALNM. MMUS nomogram based on these factors demonstrated an improved calibration and favorable performance [area under the receiver operator characteristic curve (AUC), 0.927 and 0.922 in the training and validation cohorts, respectively] compared with the clinicopathological model (AUC, 0.681 and 0.670, respectively), US-depicted ALN status (AUC, 0.710 and 0.716, respectively) and the conventional US model (AUC, 0.867 and 0.894, respectively). MMUS nomogram improved the reclassification ability of the conventional US model for ALNM prediction (net reclassification improvement, 0.296 and 0.288 in the training and validation cohorts, respectively; both P<0.001). Taken together, the findings of the present study suggested that the MMUS nomogram may be a promising, non-invasive and reliable approach for predicting ALNM.
Collapse
|
27
|
AIUM Practice Parameter for the Performance of Contrast-Enhanced Ultrasound. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:E8-E19. [PMID: 37873725 DOI: 10.1002/jum.16360] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 09/29/2023] [Indexed: 10/25/2023]
|
28
|
US Contrast Agents as Contrast Material That Remains Solely in Blood Vessels: Safety and Indications in Obstetrics and Gynecology. Radiographics 2024; 44:e240001. [PMID: 38421909 DOI: 10.1148/rg.240001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
|
29
|
Diagnostic value of contrast-enhanced ultrasound in the activity of idiopathic retroperitoneal fibrosis: a retrospective study. Clin Rheumatol 2024; 43:1207-1215. [PMID: 38329616 DOI: 10.1007/s10067-023-06855-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 11/01/2023] [Accepted: 11/24/2023] [Indexed: 02/09/2024]
Abstract
OBJECTIVES To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) in the disease activity of idiopathic retroperitoneal fibrosis (IRPF). METHODS This retrospective study included 148 CEUS examinations from 63 patients with IRPF treated in our hospital from April 2016 to September 2021. They were divided into two groups: IRPF active group (69 examinations) and inactive group (79 examinations). Uni- and multivariable analyses were used to identify independent risk factors for IRPF activity. Receiver operating characteristic (ROC) curves were drawn to establish different diagnostic models to evaluate the diagnostic value of IRPF activity. The z test was used to compare the differences of the area under the curves (AUCs). The value of CEUS in evaluating the variation of disease activity over time was also investigated between repeat patient studies. RESULTS Univariate and multivariate logistic regression analyses revealed the thickness [odds ratio (OR) = 14.125, 95% confidence interval (CI) = 3.017-66.123] was the most significant independent risk factor for IRPF activity (P < 0.01). The best diagnostic model was model 3, which was established by CEUS score combined with thickness. The AUC was 0.944 (95%CI = 0.912-0.977), and the sensitivity and specificity were 89.86% and 86.08%, respectively. The diagnostic performance was not significantly improved after combining clinical symptom (back pain) and laboratory indicators [erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP)]. Compared with before treatment, the CEUS score and thickness were significantly decreased after treatment (x2 = 14.580, P < 0.001 and z = 4.708, P < 0.001, respectively). CONCLUSION CEUS has good diagnostic value for IRPF disease activity. Key points • Thickness and contrast-enhanced ultrasound score were significantly higher in the active group than those in inactive group (P < 0.001). • With thickness of 4 mm and contrast-enhanced ultrasound 2 score as optimal cut-off values, the sensitivity and specificity were 89.86%, 81.01% and 52.17%, 100.00%, respectively. • During follow-up, when the disease progressed, the change of CEUS score was earlier than the change of thickness.
Collapse
|
30
|
Curriculum for diagnostic endoscopic ultrasound training in Europe: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement. Endoscopy 2024; 56:222-240. [PMID: 38065561 DOI: 10.1055/a-2224-8704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
The European Society of Gastrointestinal Endoscopy (ESGE) has recognized the need to formalize and enhance training in diagnostic endoscopic ultrasound (EUS). This manuscript represents the outcome of a formal Delphi process resulting in an official Position Statement of the ESGE and provides a framework to develop and maintain skills in diagnostic EUS. This curriculum is set out in terms of the prerequisites prior to training; the recommended steps of training to a defined syllabus; the quality of training; and how competence should be defined and evidenced before independent practice. 1: Trainees should have achieved competence in upper gastrointestinal endoscopy before training in diagnostic EUS. 2: The development of diagnostic EUS skills by methods that do not involve patients is advisable, but not mandatory, prior to commencing formal training in diagnostic EUS. 3: A trainee's principal trainer should be performing adequate volumes of diagnostic EUSs to demonstrate maintenance of their own competence. 4: Training centers for diagnostic EUS should offer expertise, as well as a high volume of procedures per year, to ensure an optimal level of quality for training. Under these conditions, training centers should be able to provide trainees with a sufficient wealth of experience in diagnostic EUS for at least 12 months. 5: Trainees should engage in formal training and supplement this with a range of learning resources for diagnostic EUS, including EUS-guided fine-needle aspiration and biopsy (FNA/FNB). 6: EUS training should follow a structured syllabus to guide the learning program. 7: A minimum procedure volume should be offered to trainees during diagnostic EUS training to ensure that they have the opportunity to achieve competence in the technique. To evaluate competence in diagnostic EUS, trainees should have completed a minimum of 250 supervised EUS procedures: 80 for luminal tumors, 20 for subepithelial lesions, and 150 for pancreaticobiliary lesions. At least 75 EUS-FNA/FNBs should be performed, including mostly pancreaticobiliary lesions. 8: Competence assessment in diagnostic EUS should take into consideration not only technical skills, but also cognitive and integrative skills. A reliable valid assessment tool should be used regularly during diagnostic EUS training to track the acquisition of competence and to support trainee feedback. 9: A period of supervised practice should follow the start of independent activity. Supervision can be delivered either on site if other colleagues are already practicing EUS or by maintaining contacts with the training center and/or other EUS experts. 10: Key performance measures including the annual number of procedures, frequency of obtaining a diagnostic sample during EUS-FNA/FNB, and adverse events should be recorded within an electronic documentation system and evaluated.
Collapse
|
31
|
Using 1/2 Descending Time in CEUS to Identify Renal Allograft Rejection. Acad Radiol 2024:S1076-6332(24)00048-5. [PMID: 38418346 DOI: 10.1016/j.acra.2024.01.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 01/14/2024] [Accepted: 01/22/2024] [Indexed: 03/01/2024]
Abstract
RATIONALE AND OBJECTIVES This study investigates the potential of quantitative Contrast-Enhanced Ultrasound (CEUS) parameters to distinguish between graft dysfunction due to rejection and non-rejection in kidney transplant recipients. METHODS In this retrospective study, 50 kidney transplant patients who presented elevated serum creatinine or proteinuria were analyzed. They were categorized as rejection or non-rejection based on biopsy outcomes. These classifications were applied in both derivation (n = 33) and validation cohorts (n = 17). Prior to the biopsy, all patients underwent a CEUS. Quantitative parameters derived from the CEUS were further analyzed for their consistency and reliability. Additionally, the relationship between the Banff scores, a standard for diagnosing transplant rejections, and these CEUS parameters was explored. RESULTS Significant differences between rejection and non-rejection groups were observed in the CEUS parameters of derivation cohorts. Specifically, Peak Intensity (PI), 1/2 Descending Time (DT/2), Area Under Curve (AUC), and Mean Transit Time (MTT) stood out. Sensitivity and specificity for these parameters were 76.5% and 87.5% for PI, 76.5% and 81.2% for DT/2, 76.5% and 87.5% for AUC, and 68.8% and 94.1% for MTT, respectively. DT/2 and MTT showed superior interobserver agreement compared to PI and AUC. When extrapolating the cutoff values from the derivation cohort to the validation group, DT/2 and AUC exhibited optimal diagnostic precision with positive and negative predictive values being 91.7% vs. 100% and 100% vs. 85.7%, respectively. Additionally, DT/2 effectively differentiated between mild and moderate to severe microvascular inflammation, pivotal in diagnosing antibody-mediated renal transplant rejection. CONCLUSION DT/2 from CEUS parameters presents as a reliable tool to differentiate rejection from non-rejection causes in renal transplant dysfunction. Yet, large-scale, multi-center studies are essential for further validation.
Collapse
|
32
|
A retrospective study on adverse events of intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications in 83,778 patients. Insights Imaging 2024; 15:65. [PMID: 38411872 PMCID: PMC10899544 DOI: 10.1186/s13244-024-01632-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Accepted: 01/27/2024] [Indexed: 02/28/2024] Open
Abstract
OBJECTIVES To investigate the rate of adverse events (AEs) caused by intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications retrospectively and to explore practical measures for prevention and treatment of them. MATERIALS AND METHODS This study enrolled 83,778 contrast-enhanced ultrasound (CEUS) examinations using sulfur hexafluoride microbubbles intravenously performed during 11 years. Age, gender, and target organs of all CEUS patients were recorded. For cases of AEs, their medical history and laboratory results were also collected. The process of AEs was assessed and categorized. Besides, the management of AEs were recorded. RESULTS Twenty patients had sulfur hexafluoride microbubbles-related AEs. The AE rate was 0.024%. No significant difference was observed between patients with AEs and the whole group for age and sex distribution. All AEs happened in liver examinations. Among them, 7 (35%) were mild, 8 (40%) were moderate, and 5 (25%) were severe. They were categorized into 15 allergic-like reactions and 5 physiologic reactions. The manifestations of mild and moderate AEs mainly include urticaria, chills, and mild hypoxia, which could be eased by simple management. Severe cases had anaphylactic shock, generalized convulsions, and diffuse erythema with hypotension respectively. They need close monitoring and oxygen inhalation with anti-shock and anti-anaphylactic treatment. Most cases started within 30 min and recovered within 1 day. CONCLUSIONS Intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications was safe with rare AEs. AEs were more likely to happen in abdominal applications than superficial ones. A well-designed emergency plan should be available for clinical use of sulfur hexafluoride microbubbles to reduce AEs and to deal with AEs properly. CRITICAL RELEVANCE STATEMENT Intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications reported few AEs and could be considered safe but severe AEs are life-threatening. We analyzed the influence factors of AEs and propose some methods for prevention and treatment of them, which can further improve the safety of sulfur hexafluoride microbubbles in clinical practice. KEY POINTS • The AE rate of sulfur hexafluoride microbubbles in abdominal and superficial applications was 0.024%. • Patients were more likely to have AEs in abdominal applications than superficial ones. • Severe AEs are life-threatening and need prompt identification and treatment. • We summarized some detailed suggestions for clinical prevention and treatment of AEs.
Collapse
|
33
|
A modified CEUS risk stratification model for adnexal masses with solid components: prospective multicenter study and risk adjustment. Eur Radiol 2024:10.1007/s00330-024-10639-1. [PMID: 38374482 DOI: 10.1007/s00330-024-10639-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/20/2023] [Accepted: 01/27/2024] [Indexed: 02/21/2024]
Abstract
OBJECTIVES To evaluate the additional advantages of integrating contrast-enhanced ultrasound (CEUS) into the Ovarian-Adnexal Reporting and Data System (O-RADS) ultrasound (US) for the characterization of adnexal lesions with solid components. MATERIALS AND METHODS This prospective multicenter study recruited women suspected of having adnexal lesions with solid components between September 2021 and December 2022. All patients scheduled for surgery underwent preoperative CEUS and US examinations. The lesions were categorized according to the O-RADS US system, and quantitative CEUS indexes were recorded. Pathological results served as the reference standard. Univariable and multivariable analyses were performed to identify risk factors for malignancy in adnexal lesions with solid components. Receiver operating characteristic (ROC) curve analysis was employed to assess diagnostic performance. RESULTS A total of 180 lesions in 175 women were included in the study. Among these masses, 80 were malignant and 100 were benign. Multivariable analysis revealed that serum CA-125, the presence of acoustic shadowing, and peak intensity (PI) ratio (PImass/PIuterus) of solid components on CEUS were independently associated with adnexal malignancy. The modified CEUS risk stratification model demonstrated superior diagnostic value in assessing adnexal lesions with solid components compared to O-RADS US (AUC: 0.91 vs 0.78, p < 0.001) and exhibited comparable performance to the Assessment of Different NEoplasias in the adnexa (ADNEX) model (AUC 0.91 vs 0.86, p = 0.07). CONCLUSION Our findings underscore the potential value of CEUS as an adjunctive tool for enhancing the precision of diagnostic evaluations of O-RADS US. CLINICAL RELEVANCE STATEMENT The promising performance of the modified CEUS risk stratification model suggests its potential to mitigate unnecessary surgeries in the characterization of adnexal lesions with solid components. KEY POINTS • The additional value of CEUS to O-RADS US in distinguishing between benign and malignant adnexal lesions with solid components requires further evaluation. • The modified CEUS risk stratification model displayed superior diagnostic value and specificity in characterizing adnexal lesions with solid components when compared to O-RADS US. • The inclusion of CEUS demonstrated potential in reducing the need for unnecessary surgeries in the characterization of adnexal lesions with solid components.
Collapse
|
34
|
Contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) features for characterizing serous microcystic adenomas (SMAs): In comparison to pancreatic neuroendocrine tumors (pNETs). Heliyon 2024; 10:e25185. [PMID: 38327470 PMCID: PMC10847598 DOI: 10.1016/j.heliyon.2024.e25185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 01/19/2024] [Accepted: 01/22/2024] [Indexed: 02/09/2024] Open
Abstract
Objectives Serous microcystic adenoma (SMA), a primary benign pancreatic tumor which can be clinically followed-up instead of undergoing surgery, are sometimes mis-distinguished as pancreatic neuroendocrine tumor (pNET) in regular preoperative imaging examinations. This study aimed to analyze preoperative contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) features of SMAs in comparison to pNETs. Material and methods In this retrospective study, patients with imaging-diagnosed pancreatic lesions were screened between October 2020 to October 2022 (ethical approval No. B2020-309R). Performing by a Siemens Sequoia (Siemens Medical Solutions, Mountain View, CA, USA) equipped with a 5C-1 curved array transducer (3.0-4.5 MHz), CEUS examination was conducted to observe the microvascular perfusion patterns of pancreatic lesions in arterial phase, venous/late phases (VLP) using SonoVue® (Bracco Imaging Spa, Milan, Italy) as the contrast agent. Virtual touch tissue imaging and quantification (VTIQ) - SWE was used to measure the shear wave velocity (SWV, m/s) value to represent the quantitative stiffness of pancreatic lesions. Multivariate logistic regression was performed to analyze potential ultrasound and clinical features in discriminating SMAs and pNETs. Results Finally, 30 SMA and 40 pNET patients were included. All pancreatic lesions were pathologically proven via biopsy or surgery. During the arterial phase of CEUS, most SMAs and pNETs showed iso- or hyperenhancement (29/30, 97 % and 31/40, 78 %), with a specific early honeycomb enhancement pattern appeared in 14/30 (47 %) SMA lesions. During the VLP, while most of the SMA lesions remained iso- or hyperenhancement (25/30, 83 %), nearly half of the pNET lesions revealed an attenuated hypoenhancement (17/40, 43 %). The proportion of hypoenhancement pattern during the VLP of CEUS differed significantly between SMAs and pNETs (P = 0.021). The measured SWV value of SMAs was significantly higher than pNETs (2.04 ± 0.70 m/s versus 1.42 ± 0.44 m/s, P = 0.002). Taking a SWV value > 1.83 m/s as a cutoff in differentiating SMAs and pNETs, the area under the receiver operating characteristic curve (AUROC) was 0.825, with sensitivity, specificity and likelihood ratio (+) of 85.71 %, 72.73 % and 3.143, respectively. Multivariate logistic regression revealed that SWV value (m/s) of the pancreatic lesion was an independent variable in discriminating SMA and pNET. Conclusion By comprehensively evaluating CEUS patterns and SWE features, SMA and pNET may be well differentiated before the operation. While SMA typically presents as harder lesion in VTIQ-SWE, exhibiting a specific honeycomb hyperenhancement pattern during the arterial phase of CEUS, pNET is characterized by relative softness, occasionally displaying a wash-out pattern during the VLP of CEUS.
Collapse
|
35
|
The Role of Imaging in Cervical Cancer Staging: ESGO/ESTRO/ESP Guidelines (Update 2023). Cancers (Basel) 2024; 16:775. [PMID: 38398166 PMCID: PMC10886638 DOI: 10.3390/cancers16040775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Revised: 02/10/2024] [Accepted: 02/11/2024] [Indexed: 02/25/2024] Open
Abstract
Following the European Society of Gynaecological Oncology (ESGO), the European Society for Radiotherapy and Oncology (ESTRO), and the European Society of Pathology (ESP) joint guidelines (2018) for the management of patients with cervical cancer, treatment decisions should be guided by modern imaging techniques. After five years (2023), an update of the ESGO-ESTRO-ESP recommendations was performed, further confirming this statement. Transvaginal/transrectal ultrasound (TRS/TVS) or pelvic magnetic resonance (MRI) enables tumor delineation and precise assessment of its local extent, including the evaluation of the depth of infiltration in the bladder- or rectal wall. Additionally, both techniques have very high specificity to confirm the presence of metastatic pelvic lymph nodes but fail to exclude them due to insufficient sensitivity to detect small-volume metastases, as in any other currently available imaging modality. In early-stage disease (T1a to T2a1, except T1b3) with negative lymph nodes on TVS/TRS or MRI, surgicopathological staging should be performed. In all other situations, contrast-enhanced computed tomography (CECT) or 18F-fluorodeoxyglucose positron emission tomography combined with CT (PET-CT) is recommended to assess extrapelvic spread. This paper aims to review the evidence supporting the implementation of diagnostic imaging with a focus on ultrasound at primary diagnostic workup of cervical cancer.
Collapse
|
36
|
Role of Contrast-Enhanced Ultrasound With the Enhancement Pattern and Qualitative Analysis for Differentiating Hypovascular Solid Renal Lesions. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:295-303. [PMID: 37996360 DOI: 10.1016/j.ultrasmedbio.2023.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/29/2023] [Accepted: 11/01/2023] [Indexed: 11/25/2023]
Abstract
OBJECTIVE The aim of the work described here was to explore the clinical value of contrast-enhanced ultrasound (CEUS) with the enhancement pattern and qualitative analysis in distinguishing different types of hypovascular solid renal lesions. METHODS A total of 140 patients with 140 renal tumors (all diagnosed by pathology), which manifested hypo-enhancement on CEUS, were included in this study. We compared conventional ultrasound (US) and CEUS features in five common hypovascular renal tumors, including renal angiomyolipoma (RAML), clear cell renal cell carcinoma (ccRCC), renal pelvic urothelial carcinoma (RPUC), papillary renal cell carcinoma (pRCC) and chromophobe renal cell carcinoma (chRCC). The diagnostic value of conventional US and qualitative parameters of CEUS for differentiating hypovascular solid renal lesions were evaluated. RESULTS The mean age of patients with a benign renal lesion was younger than that of patients with a malignant renal lesion (p < 0.05). Echogenicity and qualitative parameters such as wash-out, perfusion defects and perilesional rim-like enhancement (PRE) in the two groups differed significantly (all p values <0.05). Benign renal lesions exhibited mainly slow wash-out, whereas malignant renal lesions exhibited predominantly fast wash-out on CEUS (p < 0.05). There were significant differences in echogenicity, such as between RAML and ccRCC, between RAML and RPUC and between RAML and pRCC (all p values <0.05). The rates of appearance of perfusion defect in ccRCC (48%, 13/27) and pRCC (53%, 10/19) were significantly higher than the rate in RAML (14%, 6/43) (p < 0.05). The rates of appearance of PRE in ccRCC (15%, 4/27), pRCC (26%, 5/19) and chRCC (24%,4/17) were significantly higher than the rate in RAML (9%, 4/43) (p < 0.05). CONCLUSION CEUS with the enhancement pattern and qualitative analysis may be helpful in distinguishing malignant from benign hypovascular renal lesions.
Collapse
|
37
|
Diagnostic Accuracy of Contrast-Enhanced Ultrasound (CEUS) in the Detection of Muscle-Invasive Bladder Cancer: A Systematic Review and Diagnostic Meta-Analysis. Curr Oncol 2024; 31:818-827. [PMID: 38392054 PMCID: PMC10888477 DOI: 10.3390/curroncol31020060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 01/17/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024] Open
Abstract
BACKGROUND Contrast-enhanced ultrasound (CEUS) is a diagnostic tool that is gaining popularity for its ability to improve overall diagnostic accuracy in bladder cancer (BC) staging. Our aim is to determine the cumulative diagnostic performance of CEUS in predicting preoperative muscle invasiveness using a comprehensive systematic review and pooled meta-analysis. METHODS A systematic review until October 2023 was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Patients with BC suspicion were offered CEUS before the transurethral resection of the bladder tumor (TURBT). The diagnostic performance of CEUS was evaluated based on non-muscle-invasive bladder cancer (NMIBC) vs. muscle-invasive bladder cancer (MIBC) confirmed at the final histopathological examination after TURBT. The outcomes were determined through pooled sensitivity, specificity, pooled positive likelihood ratio (PLR+), negative likelihood ratio (PLR-), and area under the summary receiver operating characteristic (SROC) along with their respective 95% confidence intervals (CI). RESULTS Overall, five studies were included. In these studies, a total of 362 patients underwent CEUS prior to TURBT. The pooled sensitivity and specificity were 0.88 (95% CI: 0.81-0.93) and 0.88 (95% CI: 0.82-0.92), respectively. SROC curve depicted a diagnostic accuracy of 0.94 (95% CI: 0.81-0.98). The pooled PLR+ and PLR- were 7.3 (95% CI: 4.8-11.2) and 0.14 (95% CI: 0.08-0.23), respectively. CONCLUSIONS Our meta-analysis indicates that CEUS is highly accurate in the diagnosis and staging for BC. Beyond its accuracy, CEUS offers the advantage of being a cost-effective, safe, and versatile imaging tool.
Collapse
|
38
|
Diagnostic value of enhanced-contrast ultrasound for cesarean scar pregnancy: A systematic review. Eur J Obstet Gynecol Reprod Biol 2024; 293:119-124. [PMID: 38145593 DOI: 10.1016/j.ejogrb.2023.12.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 12/13/2023] [Accepted: 12/17/2023] [Indexed: 12/27/2023]
Abstract
BACKGROUND Cesarean scar pregnancy, an uncommon ectopic pregnancy in which the embryo is implanted in the cesarean scar, poses significant risks without prompt diagnosis and treatment. Its prevalence has risen alongside increased cesarean section rates. Despite various treatment approaches, consensus remains elusive. Ultrasonography, particularly contrast-enhanced ultrasonography, shows promise in cesarean scar pregnancy diagnosis. MAIN BODY This systematic review, following PRISMA guidelines, explores contrast-enhanced ultrasound's diagnostic potential in cesarean scar pregnancy. We searched PubMed, Scopus, Web of Science, and Google Scholar up to August 2023. Selection involved two stages: title/abstract screening and full-text assessment. The included studies investigated contrast-enhanced ultrasound's diagnostic value in cesarean scar pregnancy, provided adequate data, and were peer-reviewed in English. Quality assessment followed the QUADAS-2 criteria. We extracted the diagnostic accuracy metrics: sensitivity, specificity, and accuracy. Out of 193 records, five studies met the inclusion criteria (2016-2020, China). Contrast-enhanced ultrasound displayed sensitivities of 77%-100% and specificities of 95%-100%. Two studies reported accuracy of 96.9%-97.8%. Compared with conventional ultrasound, contrast-enhanced ultrasound exhibited superior sensitivity, specificity, and accuracy. It also outperformed transvaginal ultrasound. CONCLUSION Enhanced-contrast ultrasound holds promise for diagnosing and managing cesarean scar pregnancy by visualizing scar vascularization in real-time, thereby reducing severe complication risks. This review highlights contrast-enhanced ultrasound as a transformative diagnostic tool for cesarean scar pregnancy management, despite existing evidence limitations.
Collapse
|
39
|
Dual-modal radiomics nomogram based on contrast-enhanced ultrasound to improve differential diagnostic accuracy and reduce unnecessary biopsy rate in ACR TI-RADS 4-5 thyroid nodules. Cancer Imaging 2024; 24:17. [PMID: 38263209 PMCID: PMC10807093 DOI: 10.1186/s40644-024-00661-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Accepted: 01/10/2024] [Indexed: 01/25/2024] Open
Abstract
BACKGROUND American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS, TR) 4 and 5 thyroid nodules (TNs) demonstrate much more complicated and overlapping risk characteristics than TR1-3 and have a rather wide range of malignancy possibilities (> 5%), which may cause overdiagnosis or misdiagnosis. This study was designed to establish and validate a dual-modal ultrasound (US) radiomics nomogram integrating B-mode ultrasound (BMUS) and contrast-enhanced ultrasound (CEUS) imaging to improve differential diagnostic accuracy and reduce unnecessary fine needle aspiration biopsy (FNAB) rates in TR 4-5 TNs. METHODS A retrospective dataset of 312 pathologically confirmed TR4-5 TNs from 269 patients was collected for our study. Data were randomly divided into a training dataset of 219 TNs and a validation dataset of 93 TNs. Radiomics characteristics were derived from the BMUS and CEUS images. After feature reduction, the BMUS and CEUS radiomics scores (Rad-score) were built. A multivariate logistic regression analysis was conducted incorporating both Rad-scores and clinical/US data, and a radiomics nomogram was subsequently developed. The performance of the radiomics nomogram was evaluated using calibration, discrimination, and clinical usefulness, and the unnecessary FNAB rate was also calculated. RESULTS BMUS Rad-score, CEUS Rad-score, age, shape, margin, and enhancement direction were significant independent predictors associated with malignant TR4-5 TNs. The radiomics nomogram involving the six variables exhibited excellent calibration and discrimination in the training and validation cohorts, with an AUC of 0.873 (95% CI, 0.821-0.925) and 0.851 (95% CI, 0.764-0.938), respectively. The marked improvements in the net reclassification index and integrated discriminatory improvement suggested that the BMUS and CEUS Rad-scores could be valuable indicators for distinguishing benign from malignant TR4-5 TNs. Decision curve analysis demonstrated that our developed radiomics nomogram was an instrumental tool for clinical decision-making. Using the radiomics nomogram, the unnecessary FNAB rate decreased from 35.3 to 14.5% in the training cohort and from 41.5 to 17.7% in the validation cohorts compared with ACR TI-RADS. CONCLUSION The dual-modal US radiomics nomogram revealed superior discrimination accuracy and considerably decreased unnecessary FNAB rates in benign and malignant TR4-5 TNs. It could guide further examination or treatment options.
Collapse
|
40
|
Quantitative analysis of contrast-enhanced ultrasound in neoadjuvant treatment of locally advanced rectal cancer: a retrospective study. Front Oncol 2024; 13:1340060. [PMID: 38322290 PMCID: PMC10844946 DOI: 10.3389/fonc.2023.1340060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 12/26/2023] [Indexed: 02/08/2024] Open
Abstract
Purpose To explore the clinical value of contrast-enhanced ultrasound (CEUS) quantitative analysis in the evaluation and prognosis of neoadjuvant chemoradiotherapy for locally advanced rectal cancer (LARC). Methods Eighty-three consecutive patients undergoing neoadjuvant chemoradiotherapy and total mesorectal excision for LARC were retrospectively included. According to pathological results, patients were categorized into complete or incomplete response groups. Differences in ultrasonic parameters, pathological results, and clinical data between groups were evaluated. The cutoff point for a complete response as determined by quantitative analysis of CEUS was assessed using a receiver operating characteristic curve; additionally, overall survival (OS) and progression-free survival (PFS) were analyzed. Results Of the 83 patients, 12 (14.5%) achieved a complete response and 71 (85.5%) did not. There were significant between-group differences in carcinoembryonic antigen (CEA) levels, differentiation degree, proportion of tumor occupying the lumen, anterior-posterior and superior-inferior diameters of the lesion, and intensity of enhancement (P<0.05). CEUS quantitative analysis showed significant between-group differences in peak intensity (PI) and area under the curve (AUC) values (P<0.05). The OS and PFS of patients with high PI, high AUC value, and poorly differentiated cancer were significantly worse than those with low PI, low AUC values, and moderately to highly differentiated cancer (P<0.05). High CEA levels (hazard ratio: 1.02, 95% confidence interval: 1.01-1.04; P=0.002) and low differentiation (2.72, 1.12-6.62; P=0.028) were independent risk factors for PFS and OS. Conclusions CEUS can predict the response to neoadjuvant treatment in patients with LARC. CEUS quantitative analysis is helpful for clinical prognosis.
Collapse
|
41
|
Contrast-enhanced ultrasound reveals free-floating thrombus in carotid artery - The cause of stroke is surprisingly plaque rupture. Clin Hemorheol Microcirc 2024:CH232037. [PMID: 38277285 DOI: 10.3233/ch-232037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2024]
Abstract
BACKGROUND Acute stroke poses a serious threat to people's health. The occurrence of a thrombus following the rupture of vulnerable plaques in the carotid artery is a significant contributor to the development of stroke. In previous case reports, it has been challenging to visualize tiny ulcerations within carotid artery plaques using computed tomography angiography (CTA) and digital subtraction angiography (DSA), even when the rupture of the plaque leads to the formation of a free-floating thrombus (FFT). However, in this particular case, contrast-enhanced ultrasound (CEUS) was able to overcome this limitation and provide a more precise assessment, confirming that the FFT formation was indeed a result of plaque rupture rather than any other potential causes. Cases that utilize CEUS to visualize the formation of ulcers and FFT resulting from plaque rupture are even more rare. As such, we present this case to shed light on this infrequent phenomenon. CASE SUMMARY In this case study, we present a 65-year-old male patient who was admitted to the hospital due to headache and abnormal mental behavior for one day. During the routine cervical artery ultrasound examination upon admission, we detected the presence of plaque in the right internal carotid artery of the patient, resulting in luminal stenosis. Additionally, we observed suspected hypoechoic material at the distal end of the plaque. After undergoing CEUS examination, it was definitively determined that an ulcer had formed and a FFT had developed due to the rupture of carotid artery plaque. Subsequent CTA and DSA examinations further confirmed the presence of the FFT. The magnetic resonance imaging (MRI) reveals an acute lacunar infarction in the head of the right caput nuclei caudate, which strengthens the potential link between the patient's neurological and psychiatric symptoms observed during admission. The patient received prompt antiplatelet therapy and underwent cervical artery stenting surgery with the assistance of a distal embolic protection device. Following the procedure, the patient was discharged on the fourth day and experienced a complete recovery. CONCLUSION CEUS is a valuable tool for visualizing FFT resulting from the rupture of vulnerable plaques in the carotid artery.
Collapse
|
42
|
Value of high frame rate contrast enhanced ultrasound in gallbladder wall thickening in non-acute setting. Cancer Imaging 2024; 24:7. [PMID: 38191513 PMCID: PMC10775603 DOI: 10.1186/s40644-023-00651-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Accepted: 12/25/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND Ultrasound (US) has been widely used in screening and differential diagnosis of gallbladder wall thickening (GWT). However, the sensitivity and specificity for diagnosing wall-thickening type gallbladder cancer are limited, leading to delayed treatment or overtreatment. We aim to explore the value of high frame rate contrast enhanced ultrasound (H-CEUS) in distinguishing wall-thickening type gallbladder cancer (malignant) from GWT mimicking malignancy (benign). METHODS This retrospective study enrolled consecutive patients with non-acute GWT who underwent US and H-CEUS examination before cholecystectomy. Clinical information, US image and H-CEUS image characteristics between malignant and benign GWT were compared. The independent risk factors for malignant GWT on H-CEUS images were selected by multivariate logistic regression analysis. The diagnostic performance of H-CEUS in determining malignant GWT was compared with that of the gallbladder reporting and data system (GB-RADS) score. RESULTS Forty-six patients included 30 benign GWTs and 16 malignant GWTs. Only mural layering and interface with liver on US images were significantly different between malignant and benign GWT (P < 0.05). Differences in enhancement direction, vascular morphology, serous layer continuity, wash-out time and mural layering in the venous phase of GWT on H-CEUS images were significant between malignant and benign GWT (P < 0.05). The sensitivity, specificity and accuracy of H-CEUS based on enhancement direction, vascular morphology and wash-out time in the diagnosis of malignant GWT were 93.75%, 90.00%, and 91.30%, respectively. However, the sensitivity, specificity and accuracy of the GB-RADS score were only 68.75%, 73.33% and 71.74%, respectively. The area under ROC curve (AUC) of H-CEUS was significantly higher than that of the GB-RADS score (AUC = 0.965 vs. 0.756). CONCLUSIONS H-CEUS can accurately detect enhancement direction, vascular morphology and wash-out time of GWT, with a higher diagnostic performance than the GB-RADS score in determining wall-thickening type gallbladder cancer. This study provides a novel imaging means with high accuracy for the diagnosis of wall-thickening type gallbladder cancer, thus may be better avoiding delayed treatment or overtreatment.
Collapse
|
43
|
The value of sonographic microvascular imaging in the diagnosis of lipedema. Clin Hemorheol Microcirc 2024; 86:99-108. [PMID: 37638423 DOI: 10.3233/ch-238103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2023]
Abstract
BACKGROUND Lipedema is a chronic disease marked by symmetric enlargement of painful nodular and fibrotic adipose tissue, predominantly affecting the limbs. Since there is no specific test or biomarker for this condition, years often pass before the diagnosis of lipedema is established for the first time, thereby causing psychosocial distress, including depression, eating disorders, and social isolation. Over the last few years several advanced Doppler-based technologies have been developed to visualize slow flow blood vessels and superficial microvascular architecture undetectable by traditional color Doppler flow imaging (CDFI). OBJECTIVE The aim of this study was to evaluate the superficial microvascular anatomy in lipedema patients compared to healthy controls and investigate the clinical significance of the Ultra Micro Angiography (UMA) technology in the diagnosis of lipedema. This new technique may contribute to reduce the diagnostic delay and, eventually, establish and guide treatment strategies toward a better therapeutic outcome in lipedema patients. METHODS 25 patients with lipedema and ten healthy controls with no history of lipedema were included in this study. All ultrasound examinations were performed on a novel high-performance ultrasound system (Resona R9/Mindray) using CDFI and the UMA technique. RESULTS In all of the patients, Ultra Micro Angiography achieved the excellent visualization of microvascular structures, revealing that most lipedema patients showed grade 3 (n = 13) or grade 2 (n = 8) flow. UMA was superior to CDFI for depicting the microvascular structures. CONCLUSIONS Here we show that UMA imaging characterizes the subcutaneous microvasculature with an unprecedented accuracy. The method has the advantage of being sensitive to small, slow-flowing vessels. This allows for the assessment of the course of vessels and vascular pathologies in great detail. Thus, UMA as a non-invasive diagnostic method can improve diagnostic accuracy in lipedema.
Collapse
|
44
|
Clinical Practice Report of Contrast-Enhanced Ultrasound in Renal Artery Disease. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:117-125. [PMID: 37873731 DOI: 10.1002/jum.16345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 09/13/2023] [Accepted: 09/18/2023] [Indexed: 10/25/2023]
Abstract
OBJECTIVES To evaluate the diagnostic performance of renal artery contrast-enhanced ultrasound (CEUS) with modified inspection section and summarize subsequent changes in imaging assessment of renal artery disease. METHODS A total of 1015 patients underwent renal artery CEUS were included in the study. Among them, 79 patients (156 renal arteries) suspected with renal artery stenosis (RAS) underwent digital subtraction angiography (DSA) subsequently. DSA was used as the gold standard to evaluate the diagnostic performance of CEUS in detecting RAS (≥30%) and severe stenosis (≥70%), as well as the diagnostic accuracy of classification of stenosis degree. Besides, 127 of the 1015 patients underwent other imaging examinations such as computed tomography angiography (CTA) or magnetic resonance angiography (MRA) after CEUS and annual proportion of these imaging examinations was assessed. RESULTS The sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of CEUS for detecting RAS (≥30%) was 96.4%, 88.6%, 94.2%, 95.6% and 90.7%, respectively and the kappa value was .857 (P < .01). CEUS had a good performance in distinguishing severe stenosis (≥70%) with a sensitivity of 91.1%, specificity of 95.5%, accuracy of 92.9%, PPV of 96.5%, NPV of 88.7% and the kappa value was 0.857(P < .01). There was no significant difference between CEUS and DSA in detecting stenosis (P = 1.0) and severe stenosis (P = .227). The diagnostic accuracy of CEUS in grading RAS was 85.3% and the kappa value was 0.753 (P < .01). Besides, the annual proportion of other imaging examinations decreased for 4 consecutive years. CONCLUSIONS CEUS is a non-invasive, safe and valuable technique for the assessment of renal artery disease and worthy of promotion.
Collapse
|
45
|
Ultrasound in the Study of Thoracic Diseases: Innovative Aspects. Arch Bronconeumol 2024; 60:33-43. [PMID: 37996336 DOI: 10.1016/j.arbres.2023.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 10/11/2023] [Accepted: 10/25/2023] [Indexed: 11/25/2023]
Abstract
Thoracic ultrasound (TU) has rapidly gained popularity over the past 10 years. This is in part because ultrasound equipment is available in many settings, more training programmes are educating trainees in this technique, and ultrasound can be done rapidly without exposure to radiation. The aim of this review is to present the most interesting and innovative aspects of the use of TU in the study of thoracic diseases. In pleural diseases, TU has been a real revolution. It helps to differentiate between different types of pleural effusions, guides the performance of pleural biopsies when necessary and is more cost-effective under these conditions, and assists in the decision to remove thoracic drainage after talc pleurodesis. With the advent of COVID19, the use of TU has increased for the study of lung involvement. Nowadays it helps in the diagnosis of pneumonias, tumours and interstitial diseases, and its use is becoming more and more widespread in the Pneumology ward. In recent years, TU guided biopsies have been shown to be highly cost-effective, with other advantages such as the absence of radiation and the possibility of being performed at bedside. The use of contrast in ultrasound to increase the cost-effectiveness of these biopsies is very promising. In the study of the mediastinum and peripheral pulmonary nodules, the introduction of echobronchoscopy has brought about a radical change. It is a fully established technique in the study of lung cancer patients. The introduction of elastography may help to further improve its cost-effectiveness. In critically-ill patients, diaphragmatic ultrasound helps in the assessment of withdrawal of mechanical ventilation, and is now an indispensable tool in the management of these patients. In neuromuscular patients, ultrasound is a good predictor of impaired lung function. Currently, in Neuromuscular Disease Units, TU is an indispensable tool. Ultrasound study of the intercostal musculature is also effective in the study of respiratory function, and is widely used in Respiratory Rehabilitation. In Intermediate Care Units, thoracic ultrasound is indispensable for patient management. In these units there are ultrasound protocols for the management of patients with acute dyspnoea that have proven to be very effective.
Collapse
|
46
|
Sonothrombolysis: State-of-the-Art and Potential Applications in Children. CHILDREN (BASEL, SWITZERLAND) 2023; 11:57. [PMID: 38255371 PMCID: PMC10814591 DOI: 10.3390/children11010057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/15/2023] [Accepted: 12/27/2023] [Indexed: 01/24/2024]
Abstract
In recent years, advances in ultrasound therapeutics have been implemented into treatment algorithms for the adult population; however, the use of therapeutic ultrasound in the pediatric population still needs to be further elucidated. In order to better characterize the utilization and practicality of sonothrombolysis in the juvenile population, the authors conducted a literature review of current pediatric research in therapeutic ultrasound. The PubMed database was used to search for all clinical and preclinical studies detailing the use and applications of sonothrombolysis, with a focus on the pediatric population. As illustrated by various review articles, case studies, and original research, sonothrombolysis demonstrates efficacy and safety in clot dissolution in vitro and in animal studies, particularly when combined with microbubbles, with potential applications in conditions such as deep venous thrombosis, peripheral vascular disease, ischemic stroke, myocardial infarction, and pulmonary embolism. Although there is limited literature on the use of therapeutic ultrasound in children, mainly due to the lower prevalence of thrombotic events, sonothrombolysis shows potential as a noninvasive thrombolytic treatment. However, more pediatric sonothrombolysis research needs to be conducted to quantify the safety and ethical considerations specific to this vulnerable population.
Collapse
|
47
|
Evaluation of the diagnostic efficacy of liquid-based cytology obtained via percutaneous ultrasound-guided fine-needle aspiration for pancreatic masses: a large tertiary center's 8-year experience. J Cancer Res Clin Oncol 2023; 149:17189-17197. [PMID: 37783929 DOI: 10.1007/s00432-023-05438-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 09/18/2023] [Indexed: 10/04/2023]
Abstract
PURPOSE There were limited data on the diagnostic efficacy of liquid-based cytology (LBC) for pancreatic tissues acquired by percutaneous ultrasound-guided fine-needle aspiration (US-FNA). This study aimed to evaluate the diagnostic value of LBC acquired via percutaneous US-FNA for pancreatic tumors compared with LBC combined with smear cytology (SC). METHODS A retrospective database search (January 2014 and February 2022) was performed for patients who underwent percutaneous US-FNA with both LBC and SC. Clinical and pathological data were collected from 298 patients; eventually, 251 cases met the inclusion criteria. Diagnostic accuracy, sensitivity (SEN), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) were compared. Rapid on-site evaluation (ROSE) was not available in all cases. RESULTS Based on the pancreaticobiliary cytology guidelines published by the Papanicolaou Society of Cytopathology, 224 (89.2%), 13 (5.2%) and 14 (5.6%) cases were diagnosed as malignant, pre-malignant and benign lesions, respectively. The diagnostic accuracy of the LBC + SC (88.5%) was better than that of LBC (87.3%) but without statistical significance (P = 0.125). The SEN, SPE, PPV and NPV were 87.5%, 85.2%, 98.0% and 45.1%, respectively, in the LBC group and 88.8%, 85.2%, 98.0% and 47.9%, respectively, in the LBC + SC group. According to univariate and multivariate analyses, there were no factors have significant association with the diagnostic sensitivity of LBC. CONCLUSIONS LBC obtained via percutaneous US-FNA provides good diagnostic value for pancreatic lesions and there was no significant difference between the diagnostic accuracy of LBC and LBC + SC when ROSE was unavailable.
Collapse
|
48
|
Evaluation and Classification of Incidentally Detected Splenic Lesions Based on B-Mode and Contrast-Enhanced Ultrasound. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2023; 44:637-644. [PMID: 36731494 DOI: 10.1055/a-2001-5516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
PURPOSE To evaluate B-mode ultrasound (B-US) and contrast-enhanced ultrasound (CEUS) patterns of focal splenic incidentalomas (FSIs), and to correlate ultrasound patterns with benignity and malignancy via histologic examination and/or the clinical course. MATERIALS AND METHODS Between 2004 and 2021, 139 consecutive patients with an FSI detected by B-US were investigated additionally with CEUS. On CEUS, the arterial enhancement (AE) of the FSI (hyperenhancement, isoenhancement, hypoenhancement, and absent enhancement) was analyzed. Subsequently, the malignancy rate according to different B-US echo patterns and CEUS perfusion patterns was determined. RESULTS The final diagnosis of FSI was malignant in 9/139 (6.5%) and benign in 130/139 (93.5%) cases. The hypoechoic and hyperechoic lesions on B-US with arterial hyperenhancement on CEUS and the echogenic cystic or complex lesions on B-US with predominantly absent enhancement on CEUS were benign in 54/54 (100%) cases. 6/37 (16.2%) hypoechoic lesions on B-US with arterial hypo-/isoenhancement on CEUS and 3/48 (6.3%) of hyperechoic lesions on B-US with an arterial hypo-/isoenhancement on CEUS were malignant. CONCLUSION Based on these results, FSIs reveal different malignancy rates depending on the B-US und CEUS patterns, and classification according to these B-US and CEUS patterns may be helpful in further evaluation of an FSI.
Collapse
|
49
|
The kinetic quantitative characteristics of non-mass breast lesions with contrast-enhanced ultrasound: a prospective study. Br J Radiol 2023; 96:20221002. [PMID: 37660395 PMCID: PMC10646622 DOI: 10.1259/bjr.20221002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 08/01/2023] [Accepted: 08/15/2023] [Indexed: 09/05/2023] Open
Abstract
OBJECTIVE To characterize non-mass breast lesions (NML) quantitatively by contrast-enhanced ultrasound (CEUS) and to evaluate its additional diagnostic value based on the Breast Imaging Reporting and Data System (BI-RADS) categories. METHODS A prospective study was performed among consecutive patients with NMLs. All lesions were examined by grayscale ultrasound and CEUS and diagnosed on pathology. Standard mammograms were obtained in the patients over 30 years old. Three independent radiologists assessed the features on grayscale ultrasound and mammograms and classified NMLs according to BI-RADS categories. Combined with the quantitative analysis in CEUS, the BI-RADS categories were reassessed, and the sensitivity, specificity, positive-predictive value, negative-predictive value and area under the receiver operating characteristic curve (AUC) were calculated for the evaluation of the diagnostic performance. RESULTS 30 benign and 24 malignant NMLs were finally enrolled in this study, with ductal carcinoma in situ being the majority of malignant (15/24). Average contrast signal intensity (AI), wash-in rate (WiR) and enhancement intensity at 40 s (I40) were found to be the most efficient kinetic parameters to diagnose malignant NMLs. Combined with the cut-off values of 205.2 for AI, 127.8 for WiR and 136.4 for I40, the diagnostic accuracy was improved (AUC = 0.904), with the sensitivity of 95.8% and the specificity of 70.0%. CONCLUSION The results suggested that hyperenhancement and rapid wash-in and wash-out are the characteristics of malignant NMLs. The kinetic analysis using CEUS can reflect hypervascular nature of malignant NMLs, thus improving the diagnostic performance combined with grayscale ultrasound. ADVANCES IN KNOWLEDGE In this study, we quantified the enhancement characteristics of non-mass breast lesions with CEUS. We revealed that the combination of CEUS and conventional ultrasound provided higher sensitivity for diagnosing malignant NMLs.
Collapse
|
50
|
The role of contrast-enhanced endoscopic ultrasound for biliary diseases. J Med Ultrason (2001) 2023:10.1007/s10396-023-01385-w. [PMID: 37991545 DOI: 10.1007/s10396-023-01385-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Accepted: 09/29/2023] [Indexed: 11/23/2023]
Abstract
Contrast-enhanced endoscopic ultrasound (CE-EUS) has emerged as a promising diagnostic modality for assessing biliary diseases. CE-EUS is a noninvasive imaging technique that utilizes contrast agents to enhance the visualization of blood vessels and perfusion within target tissues. In the context of biliary diseases, CE-EUS allows for improved characterization of biliary lesions, aiding in differential diagnosis and treatment planning. This review highlights several key findings regarding the usefulness of CE-EUS in biliary disease assessment and therapeutic procedures.
Collapse
|