1
|
Lux MP, Wasner S, Meyer J, Häberle L, Hack CC, Jud S, Hein A, Wunderle M, Emons J, Gass P, Fasching PA, Egloffstein S, Krebs J, Erim Y, Beckmann MW, Loehberg CR. Analysis of Oncological Second Opinions in a Certified University Breast and Gynecological Cancer Center Regarding Consensus between the First and Second Opinion and Conformity with the Guidelines. Breast Care (Basel) 2020; 16:291-298. [PMID: 34248471 DOI: 10.1159/000509127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Accepted: 06/03/2020] [Indexed: 12/21/2022] Open
Abstract
Introduction Oncological second opinions are becoming increasingly important in the era of complex treatments and established certified cancer centers. Oncological guidelines with the highest levels of evidence are available, but these can only be effective to the extent that they are implemented. Therefore, we analyzed the effects of second opinions with regard to their agreement with first opinions and conformity with guidelines. Methods In 164 patients with a diagnosis of breast cancer or gynecological malignancy who requested a second opinion, the first and second opinions, established at the interdisciplinary tumor conference, and conformity with the guidelines were evaluated. Results The first opinion was not in agreement with the guidelines in 34.8% (15.2% diagnosis, 12.8% surgical therapy, 13.4% systemic therapy, and 5.5% radiotherapy), and the recommendations were optimized in the second opinion in 56.7% (28.7% diagnosis, 15.9% surgical therapy, 30.5% systemic therapy, and 8.5% radiotherapy). Conclusions Oncological second opinions showed significant effects and one-third of first opinions were not in conformity with the guidelines. In a significant proportion of cases, the existing treatment plan was changed or supplemented to allow modern and individualized treatment approaches.
Collapse
Affiliation(s)
- Michael P Lux
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Breast and Gynecological Cancer Center, Women's Hospital St. Louise, and St. Josefs-Krankenhaus Salzkotten, St. Vincenz Hospital GmbH Paderborn, Paderborn, Germany
| | - Sonja Wasner
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Julia Meyer
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Lothar Häberle
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Carolin C Hack
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sebastian Jud
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Alexander Hein
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Marius Wunderle
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Julius Emons
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Paul Gass
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Peter A Fasching
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Sainab Egloffstein
- Comprehensive Cancer Center Erlangen - European Metropolitan Region Nürnberg (CCC Erlangen-EMN), Erlangen, Germany
| | - Jessica Krebs
- Department of Psychosomatic and Psychotherapeutic, Erlangen University Hospital, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Yesim Erim
- Department of Psychosomatic and Psychotherapeutic, Erlangen University Hospital, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Matthias W Beckmann
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.,Comprehensive Cancer Center Erlangen - European Metropolitan Region Nürnberg (CCC Erlangen-EMN), Erlangen, Germany
| | - Christian R Loehberg
- Department of Gynecology, Erlangen University Hospital, University Breast Center and University Gynecological Cancer Center for Franconia, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| |
Collapse
|
2
|
Park C, Chevalier F, Möbus V, Hoedl P, Engelmann K, Falk S, Leithner D, Kaltenbach B, Vogl TJ, Müller-Schimpfle M. Subsequent Marking under Ultrasound Guidance of Vacuum-Assisted Breast Biopsy Areas after Receipt of Histology: A Feasibility Study of a New Technique. Breast Care (Basel) 2020; 15:628-634. [PMID: 33447237 DOI: 10.1159/000506069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Accepted: 01/21/2020] [Indexed: 11/19/2022] Open
Abstract
Purpose The aim of this study was to evaluate the feasibility and the accuracy of a secondary, metachronous ultrasound (US)-guided marking of the stereotactic vacuum-assisted breast biopsy (ST-VABB) area. Materials and Methods The institutional ethics committee approved the study. The retrospective study included 98 patients. In ST-VABB of 45 women, no tissue markers were deployed at the biopsy site, even if no residual calcifications remained. After histology proved the necessity for a subsequent operation, the biopsy site was marked under US guidance using a coil marker. All interventions were technically successful. No complications occurred. Mammography was done to visualize the coil deployment. The distances from the center of the lesion and the biopsy cavity to the coil location were measured in both planes to evaluate the accuracy of the marking procedure. Results In 24 of the 46 cases, the whole lesion was biopsied without residual elements. The mean time between ST-VABB and sonographic marking of the lesion was 9.7 days (median 6.5). The biopsy cavity could be detected in 40 (87%) cases and thus marked exactly. The mean time of US-guided marking was 12.5 min. The mean distance between the coil and the target lesion was 0.6 ± 1.5 cm in the craniocaudal (cc) view and 0.5 ± 1.5 cm in the mediolateral (ml) view for all markings. The mean delta value from the distance nipple-original lesion and from the distance nipple-coil was 0.85 ± 1.2 cm (median 0.5) in the cc view and 0.88 ± 1.2 cm (median 0.6) in the ml view for all cases. Clip migration was not observed. Conclusion Our study demonstrates the feasibility and the technical success of secondary metachronous coil marking of the biopsy site under US guidance after receipt of histology. This approach seems to be a cost-effective alternative to the standard procedure of the primary coil marking especially in all completely removed lesions. It may offer advantages for allergic patients.
Collapse
Affiliation(s)
- Clara Park
- Institute for Diagnostic and Interventional Radiology, Frankfurt University Hospital, Frankfurt am Main, Germany
| | - Frauke Chevalier
- Department of Radiology, Municipal Clinics Frankfurt/Main-Hoechst, Frankfurt am Main, Germany
| | - Volker Möbus
- Department of Gynaecology, Municipal Clinics Frankfurt/Main-Hoechst, Frankfurt am Main, Germany
| | - Petra Hoedl
- Department of Pathology, Municipal Clinics Frankfurt/Main-Hoechst, Frankfurt am Main, Germany
| | | | - Stephan Falk
- OptiPath, Pathology Associates, Frankfurt am Main, Germany
| | - Doris Leithner
- Institute for Diagnostic and Interventional Radiology, Frankfurt University Hospital, Frankfurt am Main, Germany
| | - Benjamin Kaltenbach
- Institute for Diagnostic and Interventional Radiology, Frankfurt University Hospital, Frankfurt am Main, Germany
| | - Thomas J Vogl
- Institute for Diagnostic and Interventional Radiology, Frankfurt University Hospital, Frankfurt am Main, Germany
| | - Markus Müller-Schimpfle
- Department of Radiology, Municipal Clinics Frankfurt/Main-Hoechst, Frankfurt am Main, Germany
| |
Collapse
|
3
|
Evaluation of a Marker Clip System in Sonographically Guided Core Needle Biopsy for Breast Cancer Localization Before and After Neoadjuvant Chemotherapy. Geburtshilfe Frauenheilkd 2017; 77:169-175. [PMID: 28331239 DOI: 10.1055/s-0042-124191] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Introduction The placement of intramammary marker clips has proven to be helpful for tumor localization in patients undergoing neoadjuvant chemotherapy and breast-conserving surgery. The purpose of our study was to investigate the feasibility of using a clip marker system for breast cancer localization and its influence on the imaging assessment of treatment responses after neoadjuvant chemotherapy. Patients and Methods Between March and June 2015, a total of 25 patients (n = 25), with a suspicion of invasive breast cancer with diameters of at least 2 cm (cT2), underwent preoperative sonographically guided core needle biopsy using a single-use breast biopsy system (HistoCore™) and intramammary clip marking using a directly adapted clip system based on the established O-Twist Marker™, before their scheduled preoperative neoadjuvant chemotherapy. Localization of the intramammary marker clip was controlled by sonography and digital breast tomosynthesis. Results Sonography detected no dislocation of intrammammary marker clips in 20 of 25 patients (80 %), while digital breast tomosynthesis showed accurate placement without dislocation in 24 patients (96 %) (p < 0.05). There was no evidence of significant clip migration during preoperative follow-up imaging after neoadjuvant chemotherapy. No complication related to the clip marking was noted and there was no difficulty in evaluating the treatment response to neoadjuvant chemotherapy. Among the breast-conserving surgeries performed, no cases were identified in which intraoperative loss of the marker clip had occurred. Conclusion Our study underscores the importance of intramammary marking clip systems before neoadjuvant chemotherapy. Placement of marker clips is advised to facilitate accurate tumor bed localization. With regard to digital breast tomosynthesis, its development continues to improve the quality of diagnostics and the therapy of breast cancer particularly for small breast cancer tumors or in neoadjuvant chemotherapy setting.
Collapse
|
4
|
Schaefgen B, Heil J, Richter H, Harcos A, Gomez C, Stieber A, Sohn C, Golatta M. Detection and Removal of Ceramic Clip Markers from Breast Tissue by Ultrasound-Guided, Vacuum-Assisted Minimally Invasive Biopsy in a Turkey Breast Model. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:341-345. [PMID: 27692873 DOI: 10.1016/j.ultrasmedbio.2016.08.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 07/14/2016] [Accepted: 08/20/2016] [Indexed: 06/06/2023]
Abstract
This article explores the ability of sonographically guided, vacuum-assisted minimally invasive biopsy (VAB) to detect and remove ceramic clip markers from breast tissue. This is a feasibility pre-study for a clinical study using vacuum-assisted biopsy to predict pathologic complete response of breast cancer. Twenty-six ceramic clip markers were placed in five turkey breasts. Clip markers were then detected sonographically and removed using VAB by experienced physicians. Quality of visibility was graded by the performing doctors. The specimens were examined macroscopically to see if they contained the clip marker. The main outcome measure was the accuracy of VAB to detect and remove the clip marker. The VAB device was inspected for any damage possibly caused by hitting the clip marker. The clip markers were detected in 25 cases (96.2%). Twenty clip markers (76.9%) were removed completely by VAB and five (19.2%) were partially removed. One clip marker (3.8%) was not removed. On average, detection of the clip marker took 67 s and the biopsy took 178 s. Quality of visibility was mostly graded as very good (14 cases/53.8%) or good (nine cases/34.6%), and in all of these cases the clip marker was at least partially removed. The clip marker was visible and removed in the vast majority of the cases. VAB is able to remove the clip marker in integrity without causing damage to the system.
Collapse
Affiliation(s)
| | - Jörg Heil
- University Breast Unit, Department of Gynecology, Heidelberg, Germany
| | - Hannah Richter
- University Breast Unit, Department of Gynecology, Heidelberg, Germany
| | - Aba Harcos
- University Breast Unit, Department of Gynecology, Heidelberg, Germany
| | - Christina Gomez
- University Breast Unit, Department of Gynecology, Heidelberg, Germany
| | - Anne Stieber
- University Breast Unit, Department of Gynecology, Heidelberg, Germany
| | - Christof Sohn
- University Breast Unit, Department of Gynecology, Heidelberg, Germany
| | - Michael Golatta
- University Breast Unit, Department of Gynecology, Heidelberg, Germany.
| |
Collapse
|
5
|
Heil J, Schaefgen B, Sinn P, Richter H, Harcos A, Gomez C, Stieber A, Hennigs A, Rauch G, Schuetz F, Sohn C, Schneeweiss A, Golatta M. Can a pathological complete response of breast cancer after neoadjuvant chemotherapy be diagnosed by minimal invasive biopsy? Eur J Cancer 2016; 69:142-150. [DOI: 10.1016/j.ejca.2016.09.034] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 08/23/2016] [Accepted: 09/26/2016] [Indexed: 10/20/2022]
|
6
|
Schulz-Wendtland R, Dankerl P, Dilbat G, Bani M, Fasching PA, Heusinger K, Lux MP, Loehberg CR, Jud SM, Rauh C, Bayer CM, Beckmann MW, Wachter DL, Uder M, Meier-Meitinger M, Brehm B. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips. Geburtshilfe Frauenheilkd 2015; 75:72-76. [PMID: 25684789 DOI: 10.1055/s-0034-1396164] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 11/08/2014] [Accepted: 12/05/2014] [Indexed: 10/24/2022] Open
Abstract
Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.
Collapse
Affiliation(s)
- R Schulz-Wendtland
- Gynäkologische Radiologie, Radiologisches Institut + Universitätsklinikum Erlangen, Erlangen
| | - P Dankerl
- Radiologisches Institut, Universitätsklinikum Erlangen, Erlangen
| | - G Dilbat
- Radiologie, Radiologie Roth, Roth
| | - M Bani
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - P A Fasching
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - K Heusinger
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - M P Lux
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - C R Loehberg
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - S M Jud
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - C Rauh
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - C M Bayer
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - M W Beckmann
- Frauenklinik, Universitätsklinikum Erlangen, Erlangen
| | - D L Wachter
- Pathologisches Institut, Universitätsklinikum Erlangen, Erlangen
| | - M Uder
- Radiologisches Institut, Universitätsklinikum Erlangen, Erlangen
| | - M Meier-Meitinger
- Gynäkologische Radiologie, Radiologisches Institut + Universitätsklinikum Erlangen, Erlangen
| | - B Brehm
- Gynäkologische Radiologie, Radiologisches Institut + Universitätsklinikum Erlangen, Erlangen
| |
Collapse
|