Nidunganda RN, Keethadath A, Paul P, Nair KCS, Vijay AS, Thachampatta MR. Dorsal Bridge Plating for Comminuted Distal Radius Fractures: Functional Outcomes of Distal Fixation on 2nd Metacarpal versus 3rd Metacarpal.
J Orthop Case Rep 2025;
15:256-260. [PMID:
40351607 PMCID:
PMC12064241 DOI:
10.13107/jocr.2025.v15.i05.5626]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2025] [Revised: 03/11/2025] [Indexed: 05/14/2025] Open
Abstract
Purpose
To compare the functional outcome of distal fixation on the second metacarpal versus the third metacarpal in patients treated with dorsal bridge plating for comminuted intra-articular distal radius fractures.
Materials and Methods
The functional outcome of 60 patients treated with dorsal bridge plating was assessed 6 months postoperatively comparing distal fixation on the second metacarpal versus the third metacarpal. Pain, ability to work post-fixation, range of movements, stiffness, and grip strength were the parameters assessed.
Results
Distal fixation on the third metacarpal resulted in more stiffness and risk of tendon entrapment of the first and third extensor compartments when compared to distal fixation on the second metacarpal.
Conclusion
Dorsal bridge plating with a distal fixation on the second metacarpal shower better functional outcome compared to the third metacarpal with a better range of movements, less risk of tendon entrapment, and better fracture stabilization.
Collapse