1
|
Collins JR, Ogando BP, Hong H, Hou W, Romanos GE. Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series. Dent J (Basel) 2022; 10:dj10060113. [PMID: 35735655 PMCID: PMC9221962 DOI: 10.3390/dj10060113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/06/2022] [Accepted: 06/15/2022] [Indexed: 02/04/2023] Open
Abstract
The objective of this study was to evaluate the clinical and radiographic behavior of a novel triangular neck implant configuration in partially edentulous patients. Sixteen patients with a mean age of 58.3 years, were rehabilitated with 25 implants inserted in the healed sites of the maxilla and mandible; implant diameter was Ø3.3 and 3.9 mm. Clinical and radiographic measurements were first performed at prosthesis delivery that served as baseline; they were further evaluated after a mean period of 15.6 months. The interproximal peri-implant bone levels were the primary outcome; the mesial and distal data were recorded and a mean value was calculated. Secondary outcomes included peri-implant probing depth (PPD) and bleeding on probing (BoP). The paired t-test was used to compare the radiographic and clinical outcomes between baseline and follow-up. The mean bone levels at the mesial and distal aspects at baseline were 0.45 (0.47) and 0.57 (0.69), respectively; at follow-up they were 0.59 (0.42) and 0.78 (0.59), respectively. The differences were not statistically significant. Similarly, no significant differences were found for the clinical parameters. Within the limitations of the present study, it could be concluded that this new triangular neck bone level implant macro-design was used successfully to treat partially edentulous patients. Larger controlled clinical studies are warranted to confirm the present radiographic and clinical findings.
Collapse
Affiliation(s)
- James Rudolph Collins
- Department of Periodontology, School of Dentistry, Pontificia Universidad Católica Madre y Maestra (PUCMM), Santo Domingo 10109, Dominican Republic; (J.R.C.); (B.P.O.)
| | - Brendha P. Ogando
- Department of Periodontology, School of Dentistry, Pontificia Universidad Católica Madre y Maestra (PUCMM), Santo Domingo 10109, Dominican Republic; (J.R.C.); (B.P.O.)
| | - Houlin Hong
- School of Public Health & Health Policy, City University of New York, New York, NY 10031, USA;
| | - Wei Hou
- Department of Family, Population and Preventive Medicine, School of Medicine, Stony Brook University, New York, NY 11794, USA;
| | - Georgios E. Romanos
- Department of Periodontology, School of Dental Medicine, Stony Brook University, New York, NY 11794, USA
- Correspondence:
| |
Collapse
|
2
|
Harawaza K, Cousins B, Roach P, Fernandez A. Modification of the surface nanotopography of implant devices: A translational perspective. Mater Today Bio 2021; 12:100152. [PMID: 34746736 PMCID: PMC8554633 DOI: 10.1016/j.mtbio.2021.100152] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 10/16/2021] [Accepted: 10/19/2021] [Indexed: 01/24/2023] Open
Abstract
There is an increasing need for the development of superior, safe, and more sophisticated implants, especially as our society historically has been moving towards an increasingly aging population. Currently, most research is being focused on the next generation of advanced medical implants, that are not only biocompatible but have modified surfaces that direct specific immunomodulation at cellular level. While there is a plethora of information on cell-surface interaction and how surfaces can be nanofabricated at research level, less is known about how the academic knowledge has been translated into clinical trials and commercial technologies. In this review, we provide a clinical translational perspective on the use of controlled physical surface modification of medical implants, presenting an analysis of data acquired from clinical trials and commercial products. We also evaluate the state-of-the-art of nanofabrication techniques that are being applied for implant surface modification at a clinical level. Finally, we identify some current challenges in the field, including the need of more advanced nanopatterning techniques, the comparatively small number of clinical trials and comment on future avenues to be explored for a successful clinical translation.
Collapse
Affiliation(s)
- K. Harawaza
- Chemistry Department, School of Science, Loughborough University, Loughborough, LE11 3TU, UK
| | - B. Cousins
- Chemistry Department, School of Science, Loughborough University, Loughborough, LE11 3TU, UK
| | - P. Roach
- Chemistry Department, School of Science, Loughborough University, Loughborough, LE11 3TU, UK
| | - A. Fernandez
- Chemistry Department, School of Science, Loughborough University, Loughborough, LE11 3TU, UK
| |
Collapse
|
3
|
Kim HG, Yun PY, Kim YK, Kim IH. Comparison of sandblasted and acid-etched surface implants and new hydrophilic surface implants in the posterior maxilla using a 3-month early-loading protocol: a randomized controlled trial. J Korean Assoc Oral Maxillofac Surg 2021; 47:175-182. [PMID: 34187957 PMCID: PMC8249194 DOI: 10.5125/jkaoms.2021.47.3.175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Revised: 01/21/2021] [Accepted: 02/01/2021] [Indexed: 12/01/2022] Open
Abstract
Objectives In this prospective randomized controlled trial, we measured the primary and secondary stability of two surface-treated implants placed in the posterior maxilla, applied 3-month loading protocols, and compared and analyzed the short-term outcomes of the implants. Patients and Methods From June 2018 to June 2019, patients with a residual bone height of 4 mm in the posterior maxilla were enrolled and randomly divided into two groups to place SA implants (Osstem Implants, Korea) in Group A and NH implants (Hiossen, USA) in Group B. Finally, 14 implants placed in 13 patients in Group A and 17 implants placed in 14 patients in Group B were analyzed. The measured primary and secondary stability of each implant was represented by implant stability quotient (ISQ), and treatment outcomes were evaluated. Results Group A consisted of patients with an average age of 62.2 years (range, 48-80 years), and Group B consisted of patients with an average age of 58.1 years (range, 35-82 years). Primary stability was 73.86±6.40 and 71.24±5.32 in Groups A and B, respectively (P=0.222). Secondary stability was 79.07±5.21 in Group A and 78.29±4.74 in Group B (P=0.667). A steep increase in ISQ during the healing period was observed in Group B, though it was not significant (P=0.265). The mean follow-up period was 378.5±164.6 days in Group A and 385.3±167.9 days in Group B. All implants in each group met the success criteria, and the success rate was 100%. Conclusion Two surface-treated implants placed in the posterior maxilla with greater than 4 mm alveolar bone height exhibited successful one-year treatment outcomes if a primary stability of 65 or higher ISQ was obtained and a 3-month early loading protocol was applied.
Collapse
Affiliation(s)
- Hyeong Gi Kim
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Korea.,Office of Human Resources Development, Armed Forces Capital Hospital, Armed Forces Medical Command, Seongnam, Korea
| | - Pil-Young Yun
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Korea
| | - Young-Kyun Kim
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Korea.,School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Korea.,Department of Oral and Maxillofacial Surgery, Armed Forces Capital Dental Hospital, Armed Forces Medical Command, Seongnam, Korea
| | - Il-Hyung Kim
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, Seongnam, Korea.,Department of Oral and Maxillofacial Surgery, Armed Forces Capital Dental Hospital, Armed Forces Medical Command, Seongnam, Korea
| |
Collapse
|
4
|
Jinno Y, Stocchero M, Galli S, Toia M, Becktor JP. Impact of a Hydrophilic Dental Implant Surface on Osseointegration: Biomechanical Results in Rabbit. J ORAL IMPLANTOL 2021; 47:163-168. [PMID: 32663272 DOI: 10.1563/aaid-joi-d-19-00217] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This study aimed to evaluate the effect of surface hydrophilicity on the biomechanical aspects of osseointegration of dental implants in the tibia and femur of rabbits. Forty-eight mature female New Zealand White rabbits were included, and 96 commercially pure, Grade 4, titanium dental implants (control group), and 96 implants of same macro geometry with the hydrophilic surface (test group) were used in this study. One osteotomy was performed in each tibia and femur on both sides of the rabbit, and four implants were placed in each rabbit. Control and test groups were randomly allocated on the left and right sides. During surgery, insertion torque (ITQ) value of the complete implant placement was recorded. After healing periods of 0, 2, 4, and 8 weeks after surgery, implant stability quotient (ISQ) value, and removal torque (RTQ) values were measured. No statistical difference was observed for ITQ, for ISQ and for RTQ between the control group and test group in tibia/femur for all time periods. The effect of hydrophilic properties on moderately roughened surfaces has no impact in terms of biomechanical outcomes (ISQ values and RTQ values) after a healing period of 2 to 8 weeks in rabbit tibias /femurs.
Collapse
Affiliation(s)
- Yohei Jinno
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Michele Stocchero
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Silvia Galli
- Department of Prosthodontics, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Marco Toia
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Jonas P Becktor
- Department of Oral and Maxillofacial Surgery and Oral Medicine, Faculty of Odontology, Malmö University, Malmö, Sweden
| |
Collapse
|
5
|
Abaricia JO, Shah AH, Ruzga MN, Olivares-Navarrete R. Surface characteristics on commercial dental implants differentially activate macrophages in vitro and in vivo. Clin Oral Implants Res 2021; 32:487-497. [PMID: 33502059 DOI: 10.1111/clr.13717] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/16/2020] [Accepted: 01/20/2021] [Indexed: 12/11/2022]
Abstract
OBJECTIVES Biomaterial implantation provokes an inflammatory response that controls integrative fate. M2 macrophages regulate the response to implants by resolving the inflammatory phase and recruiting progenitor cells to aid healing. We have previously shown that modified titanium (Ti) disks directly induce M2 macrophage polarization. The aim of this study was to examine macrophage response to commercially available Ti or Ti alloy implants with comparable roughness and varying hydrophilicity. MATERIAL AND METHODS Eleven commercially available Ti (A-F) or Ti alloy (G-K) dental implants were examined in this study. Surface topography, chemistry, and hydrophilicity were characterized for each implant. To compare the immune response in vitro, human monocyte-derived macrophages were seeded on implants and secreted pro- and anti-inflammatory proteins measured. To evaluate the inflammatory response in vivo, mice were subcutaneously instrumented with clinical implants, and implant adherent macrophage populations were characterized by flow cytometry. RESULTS Macrophages on hydrophobic Implant C produced the highest level of pro-inflammatory proteins in vitro. In contrast, hydrophilic Implant E produced the second-highest pro-inflammatory response. Implants F and K, both hydrophilics, produced the highest anti-inflammatory protein secretions. Likewise, pro-inflammatory CD80hi macrophages predominated in vivo on implants C and E, and M2 CD206 + macrophages predominated on implants F and K. CONCLUSIONS These findings show that hydrophilicity alone is insufficient to predict the anti-inflammatory effect on macrophage polarization and that other properties-surface composition or topography-determine immune modulation. This in vivo model may be a useful screening method to compare the immunomodulatory response to clinical implants of disparate geometry or size.
Collapse
Affiliation(s)
- Jefferson O Abaricia
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Arth H Shah
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, USA
| | - Marissa N Ruzga
- Department of Biomedical Engineering, College of Engineering, Ohio State University, Columbus, OH, USA
| | - Rene Olivares-Navarrete
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, VA, USA
| |
Collapse
|
6
|
Tallarico M, Baldini N, Gatti F, Martinolli M, Xhanari E, Meloni SM, Gabriele C, Immacolata LA. Role of New Hydrophilic Surfaces on Early Success Rate and Implant Stability: 1-Year Post-loading Results of a Multicenter, Split-Mouth, Randomized Controlled Trial. Eur J Dent 2020; 15:1-7. [PMID: 33242915 PMCID: PMC7902108 DOI: 10.1055/s-0040-1713952] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
OBJECTIVE To compare early implant failure and implant stability of one-stage Hiossen ET III implants with its new hydrophilic (NH) surface, compared with Hiossen ET III implants with the sandblasted and acid-etched (SA) surface at 1-year follow-up. MATERIALS AND METHODS This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values. RESULTS Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17-41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02-41.98) Ncm in the NH group (p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group (p = 0.041). Similar results were found in the maxilla (p = 0.045), but not in the mandible (p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66). CONCLUSIONS NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.
Collapse
Affiliation(s)
| | - Nicola Baldini
- Department of Periodontics and Implantology, University of Siena, Siena, Italy
| | - Fulvio Gatti
- Department of Biomedical, Surgical and Dental Sciences, Unit of Oral Surgery, San Carlo and San Paolo Hospital, University of Milan, Milan, Italy
| | | | - Erta Xhanari
- School of Dentistry, University of Sassari, Sassari, Italy
| | - Silvio Mario Meloni
- Medical Surgical and Experimental Science Department, University of Sassari, Sassari, Italy
| | - Cervino Gabriele
- Department of BIOMORF, School of Dentistry, University of Messina, Messina, Italy
| | | |
Collapse
|
7
|
Cervino G, Cicciù M, Fedi S, Milone D, Fiorillo L. FEM Analysis Applied to OT Bridge Abutment with Seeger Retention System. Eur J Dent 2020; 15:47-53. [PMID: 32869222 PMCID: PMC7902099 DOI: 10.1055/s-0040-1715550] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
Abstract
OBJECTIVE The purpose of this investigation is to highlight the technical components of a new kind of screw-retained dental implant prosthesis. The hypothesis is whether the OT Bridge (Rhein 83 S.R.L.; Bologna, Italy) system could be applied without secondary screw in the "all-on-four" retention system, thanks to the presence of an internal seeger. MATERIALS AND METHODS By using engineering device such as finite element method (FEM) and von Mises investigation, it has been studied how the fixed prosthodontics for full-arch retention can be influenced by the presence of the screw for stabilizing it. RESULTS In a dental implant, one model with four different configurations of the full-arch prosthesis retainer and the seeger has been investigated and then examined in contrast with or without the passant screw for locking the system. The experiments of this virtual study highlighted different features and mechanical behaviors of prosthodontic attachments. CONCLUSION The first two configurations, respectively those in which there are four and three connection screws, are safe and predictable. Therefore, the presence of the seeger significantly improves the stability and the retention of the whole prosthesis.
Collapse
Affiliation(s)
- Gabriele Cervino
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, Messina, Italy
| | - Marco Cicciù
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, Messina, Italy
| | - Simone Fedi
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, Messina, Italy
| | - Dario Milone
- Department of Engineering, Messina University, Messina, Italy
| | - Luca Fiorillo
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, Messina, Italy
| |
Collapse
|
8
|
Almassri HNS, Ma Y, Dan Z, Ting Z, Cheng Y, Wu X. Implant stability and survival rates of a hydrophilic versus a conventional sandblasted, acid-etched implant surface: Systematic review and meta-analysis. J Am Dent Assoc 2020; 151:444-453. [PMID: 32450983 DOI: 10.1016/j.adaj.2020.03.002] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 02/27/2020] [Accepted: 03/05/2020] [Indexed: 01/10/2023]
Abstract
BACKGROUND Modifying the implant surface via enhancing the wettability (hydrophilicity) improves osseointegration, reducing the healing period. In this study, the authors aimed to evaluate the stability and survival rates of implants with a hydrophilic surface compared with those with a sandblasted, acid-etched surface. TYPES OF STUDIES REVIEWED The included studies (randomized controlled trials) were identified through searches of PubMed, ScienceDirect, and Cochrane Library databases without date of publication restrictions. Quality assessment was performed using the Cochrane Collaboration tool. For primary outcome, confidence intervals were set at 95%; weighted means across the studies were calculated using a fixed-effects model or risk ratios and their 95% confidence intervals for secondary outcome. RESULTS The authors included 5 randomized controlled trials (246 dental implants) in the systematic review, which compared a hydrophilic with conventional sandblasted, acid-etched implant surface. The implant stability (primary outcome) was measured at baseline and 3, 6, and 8 weeks, and implant survival rates were measured as a secondary outcome. Overall, compared with the control groups, no clinically significant differences in implant stability or survival rates were identified for the hydrophilic surface groups. CONCLUSIONS AND PRACTICAL IMPLICATIONS The results did not show any clinically significant effect of a hydrophilic surface on improving implant stability or survival rates. However, these findings must be analyzed carefully owing to the limitations of this review, such as the small samples size and some differences among the included studies.
Collapse
|
9
|
Arya G, Kumar V. Evaluation of osseintegration between traditional and modified hydrophilic titanium dental implants - Systematic analysis. Natl J Maxillofac Surg 2020; 11:176-181. [PMID: 33897177 PMCID: PMC8051648 DOI: 10.4103/njms.njms_44_20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/19/2020] [Accepted: 07/04/2020] [Indexed: 11/16/2022] Open
Abstract
The aim of the study was to conduct a systematic review to access the osseointegration between traditional and modified Hydrophilic Titanium Dental Implants for period of 10 years. PUBMed articles were searched from last ten years up to 15/12/2019 from which 24 studies included in this review. This systematic review compiles the data about osseintegration in hydrophilic titanium implants in human trials. It sheds light on the mechanism of integration of hydrophilic surfaces and numeric data to support the purpose of the review.
Collapse
Affiliation(s)
- Geeta Arya
- Department of Prosthodontics and Oral Implantology, Seema Dental College and Hospital, Rishikesh, Uttarakhand, India
| | - Varun Kumar
- Department of Prosthodontics and Oral Implantology, Seema Dental College and Hospital, Rishikesh, Uttarakhand, India
| |
Collapse
|
10
|
Alshehri F, Alshehri M, Sumague T, Niazy A, Jansen J, van den Beucken J, Alghamdi H. Evaluation of Peri-Implant Bone Grafting Around Surface-Porous Dental Implants: An In Vivo Study in a Goat Model. MATERIALS 2019; 12:ma12213606. [PMID: 31684138 PMCID: PMC6862611 DOI: 10.3390/ma12213606] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 10/22/2019] [Accepted: 10/30/2019] [Indexed: 12/11/2022]
Abstract
Dental implants with surface-porous designs have been recently developed. Clinically, peri-implant bone grafting is expected to promote early osseointegration and bone ingrowth when applied with surface-porous dental implants in challenging conditions. The aim of this study was to comparatively analyze peri-implant bone healing around solid implants and surface-porous implants with and without peri-implant bone grafting, using biomechanical and histomorphometrical assessment in a goat iliac bone model. A total of 36 implants (4.1 mm wide, 11.5 mm long) divided into three groups, solid titanium implant (STI; n = 12), porous titanium implants (PTI; n = 12) and PTI with peri-implant bone grafting using biphasic calcium phosphate granules (PTI + BCP; n = 12), were placed bilaterally in the iliac crests of six goats. The goats were sacrificed seven weeks post-operatively and then subjected to biomechanical (n = 6 per group) and histomorphometrical (n = 6 per group) assessment. The biomechanical assessment revealed no significant differences between the three types of implants. Although the peri-implant bone-area (PIBA%) measured by histomorphometry (STI: 8.63 ± 3.93%, PTI: 9.89 ± 3.69%, PTI + BCP: 9.28 ± 2.61%) was similar for the three experimental groups, the percentage of new bone growth area (BGA%) inside the porous implant portion was significantly higher (p < 0.05) in the PTI group (10.67 ± 4.61%) compared to the PTI + BCP group (6.50 ± 6.53%). These data demonstrate that peri-implant bone grafting around surface-porous dental implants does not significantly accelerate early osseointegration and bone ingrowth.
Collapse
Affiliation(s)
- Fahad Alshehri
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
| | - Mohammed Alshehri
- Dental Department, King Khalid University Hospital, King Saud University, Riyadh 11545, Saudi Arabia.
| | - Terrence Sumague
- Molecular and Cell Biology Laboratory, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
| | - Abdurahman Niazy
- Molecular and Cell Biology Laboratory, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
| | - John Jansen
- Department of Regenerative Biomaterials, Radboudumc, 6525EX Nijmegen, The Netherlands.
| | | | - Hamdan Alghamdi
- Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
- Molecular and Cell Biology Laboratory, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia.
| |
Collapse
|