1
|
Loganathan PK, Meau-Petit V, Bhojnagarwala B, Nair V, Holmes J, Occhipinti A, Montasser M. Serial lung ultrasound in predicting the need for surfactant and respiratory course in preterm infants-multicentre observational study (SLURP). Eur J Pediatr 2025; 184:356. [PMID: 40407825 PMCID: PMC12102118 DOI: 10.1007/s00431-025-06185-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2025] [Revised: 05/06/2025] [Accepted: 05/12/2025] [Indexed: 05/26/2025]
Abstract
Lung ultrasound (LUS) scores may predict surfactant need early and the progression of the respiratory course in preterm infants. The objective of this study is to report the diagnostic value of LUS scores performed by operators of varying levels of experience to predict the need for surfactant in preterm infants. A prospective observational study was conducted across 3 UK-based neonatal intensive care units. Preterm infants ≤ 34 weeks on non-invasive respiratory support within 3 h of birth were included. Ten lung zones were scored serially, first within the first 3 h of life, then at 12-24-h intervals (a total of four scans). All scans were performed by the local team members with formal training on LUS and varying levels of expertise. All the LUS videos were scored by an expert investigator who was blinded to clinical details. Written retrospective parental consents were obtained. We recruited 83 preterm infants ≤ 34 weeks (May 2023 to June 2024). A total of 325 LUS scans were performed by 27 clinical staff. The median birth gestational age and birth weight were 31 weeks and 1515 g, respectively. Twenty-eight (34%) babies received surfactants. The first LUS using a 6-zone method within 3 h of life predicted surfactant need and bronchopulmonary dysplasia with an AUC of 0.80 for both outcomes, offering sensitivity (79% and 73%) and specificity (75% and 76%), respectively. CONCLUSIONS LUS performed by operators of varying levels of experience within the first 3 h of life is a reliable tool for predicting surfactant need in preterm infants ≤ 34 weeks. TRIAL REGISTRATION ClinicalTrials.gov ( https://clinicaltrials.gov/ ): NCT05782569. WHAT IS KNOWN • There are considerable variations in the selection criteria of preterm infants for surfactant administration. • Lung ultrasound score has been shown to predict the need for surfactant early and the progression of respiratory course in preterm infants. WHAT IS NEW • LUS performed within 3 h of life by operators of varying levels of experience and interpreted by expert predicted the need for surfactant deficiency in preterm infants. • Our research with a structured training programme enabled novice operators to perform LUS and achieve reasonable competency.
Collapse
Affiliation(s)
- P K Loganathan
- Neonatal Unit, James Cook University Hospital, Marton Road, Middlesbrough, TS4 3BW, UK.
- Clinical Academic Office, Faculty of Medical Sciences, Newcastle University, Newcastle, UK.
- University of Durham, Durham, DH1 3LE, UK.
| | - V Meau-Petit
- Neonatal and Paediatric Intensive Care Unit, Franco-Britannique Hospital, Levallois-Perret, France
| | - B Bhojnagarwala
- Oliver Fisher Neonatal Unit, Medway NHS Foundation Trust, Kent, UK
| | - V Nair
- Neonatal Unit, James Cook University Hospital, Marton Road, Middlesbrough, TS4 3BW, UK
- Translational and Clinical Research Institute, Newcastle University, Newcastle, UK
| | - J Holmes
- School of Computing, Engineering and Digital Technologies, Teesside University, Middlesbrough, UK
| | - A Occhipinti
- School of Computing, Engineering and Digital Technologies, Teesside University, Middlesbrough, UK
| | - M Montasser
- Neonatal Unit, University Hospital Wishaw, Scotland, UK
| |
Collapse
|
2
|
Mohamed A, Mohsen N, Ibrahim J, Lee S, Kharrat A, Shah PS, Jain A. Association of lung ultrasound score with large patent ductus arteriosus in preterm neonates during the transitional period. Eur J Pediatr 2025; 184:348. [PMID: 40392344 DOI: 10.1007/s00431-025-06186-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2025] [Revised: 04/17/2025] [Accepted: 05/12/2025] [Indexed: 05/22/2025]
Abstract
Recent studies suggested lung ultrasound (LU) as a useful, non-invasive bedside tool for assessing pulmonary edema; however, its utility in identifying preterm neonates with large patent ductus arteriosus (L-PDA) is limited. The objective of the study is to evaluate the association of LU score (LUS) in preterm neonates with L-PDA during the transitional period and explore correlation of LUS with echocardiographic indicators. Among 152 neonates born < 29 weeks' gestation and had LU performed at day-of-life (DOL) three for a previous prospective study, 54 neonates had concomitant echocardiography (Echo) documenting PDA presence, diameter, and variables for shunt volume. We included in the analysis neonates who had LU and Echo on DOL 3. Neonates with L-PDA were compared to those with absent or small PDA. Univariate, multivariate, and Pearson's correlation coefficients analyses were conducted. Of the 54 infants included in the study, 32 (59%) were diagnosed with L-PDA. There were no significant differences in baseline characteristics between the L-PDA and no-L-PDA group. Univariate analysis showed no association between LUS and L-PDA. Similarly, multivariate analysis found that a one-point increment of LUS was not associated to L-PDA (adjusted OR 1.19; 95% CI 0.89-1.59). LUS demonstrated a significant correlation with respiratory severity score and a weak correlation with PDA diameter, but no significant associations with other PDA shunt volume variables. CONCLUSION In this cohort, LUS was not associated with L-PDA during the transition period. Larger studies are required to confirm these findings and further explore the clinical utility of LUS in assessing PDA. WHAT IS KNOWN • Lung ultrasound (LUS) is a non-invasive tool for assessing pulmonary edema in preterm neonates. • Previous studies have reported a positive correlation between LUS score and hemodynamically significant PDA. WHAT IS NEW • In this cohort of preterm neonates 29 weeks, LUS was not associated with large PDA during the transitional period (DOL 3). • LUS showed correlation with respiratory severity but not with echocardiographic markers of PDA shunt volume.
Collapse
Affiliation(s)
- Adel Mohamed
- Department of Paediatrics, University of Toronto, Toronto, ON, Canada.
- Department of Paediatrics, Mount Sinai Hospital, 600 University Avenue, Toronto, Ontario, M5G 1X5, Canada.
| | - Nada Mohsen
- Department of Paediatrics, Mansoura University, Mansoura, Egypt
| | - Jenna Ibrahim
- Department of Paediatrics, University of Toronto, Toronto, ON, Canada
| | - Seungwoo Lee
- Department of Paediatrics, Mount Sinai Hospital, 600 University Avenue, Toronto, Ontario, M5G 1X5, Canada
| | - Ashraf Kharrat
- Department of Paediatrics, University of Toronto, Toronto, ON, Canada
- Department of Paediatrics, Mount Sinai Hospital, 600 University Avenue, Toronto, Ontario, M5G 1X5, Canada
| | - Prakesh S Shah
- Department of Paediatrics, University of Toronto, Toronto, ON, Canada
- Department of Paediatrics, Mount Sinai Hospital, 600 University Avenue, Toronto, Ontario, M5G 1X5, Canada
| | - Amish Jain
- Department of Paediatrics, University of Toronto, Toronto, ON, Canada
- Department of Paediatrics, Mount Sinai Hospital, 600 University Avenue, Toronto, Ontario, M5G 1X5, Canada
| |
Collapse
|
3
|
Velázquez-Iglesias S, Moreno-Rodilla V, Curto-Diego B, Pérez-Robledo F, Llamas-Ramos R, Calvo-Arenillas JI, Llamas-Ramos I. Postural Analysis in Ventral and Dorsal Decubitus Babies Using Deep Learning Techniques: A Protocol Study. J Clin Med 2025; 14:3096. [PMID: 40364127 PMCID: PMC12072809 DOI: 10.3390/jcm14093096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2025] [Revised: 04/06/2025] [Accepted: 04/25/2025] [Indexed: 05/15/2025] Open
Abstract
Background: The analysis of posture in the early stages of motor development has always been a subject of research and study. With the evolution of new technologies, the need arises to implement evaluation tools that allow an objective and effective assessment of postural control, which is intrinsically linked to motor development. Objectives: The objective was to analyze posture in babies from 0 to 6 months in ventral and dorsal decubitus using artificial intelligence to determine objective parameters of postural assessment. Methods: The study is an observational and cross-sectional study. The babies will be studied following a systematic kinesiological assessment, and the images of the babies will be taken, both in ventral and dorsal decubitus, on a glass platform, to analyze their posture by means of deep learning techniques. Results: Many authors have investigated posture in newborns. However, there is no method for assessing motor and postural development to determine the support area of typically developing babies. Artificial intelligence is postulated as an effective tool to objectively analyze the posture of babies and detect possible delays. Using deep learning techniques as a predictive tool, the support areas of each baby will be defined according to their age. Conclusions: Early detection of motor or postural developmental delays in babies to optimize effective treatment is of great importance. Artificial intelligence can help manage the complexity and growing volume of data in healthcare by knowing the correct postural control at each stage of a baby's early months, while reducing the workload of healthcare professionals by facilitating decision-making.
Collapse
Affiliation(s)
| | - Vidal Moreno-Rodilla
- G.I.R “Robotics and Society”, Dpt. Computers and Automation, Faculty of Sciences, Universidad de Salamanca, 37008 Salamanca, Spain
| | - Belén Curto-Diego
- G.I.R “Robotics and Society”, Dpt. Computers and Automation, Faculty of Sciences, Universidad de Salamanca, 37008 Salamanca, Spain
| | - Fátima Pérez-Robledo
- Department of Nursing and Physiotherapy, Universidad de Salamanca, 37007 Salamanca, Spain
- Instituto de Investigación Biomédica de Salamanca (IBSAL), 37007 Salamanca, Spain
| | - Rocío Llamas-Ramos
- Department of Nursing and Physiotherapy, Universidad de Salamanca, 37007 Salamanca, Spain
- Instituto de Investigación Biomédica de Salamanca (IBSAL), 37007 Salamanca, Spain
| | | | - Inés Llamas-Ramos
- Department of Nursing and Physiotherapy, Universidad de Salamanca, 37007 Salamanca, Spain
- Instituto de Investigación Biomédica de Salamanca (IBSAL), 37007 Salamanca, Spain
- University Hospital of Salamanca, Health Service of Castile and Leon (SACyL), P.º de San Vicente, 182, 37007 Salamanca, Spain
| |
Collapse
|
4
|
Savoia M, Busolini E, Ibarra Rios D, Thomas B, Ruoss JL, McNamara PJ. Integrated Lung Ultrasound and Targeted Neonatal Echocardiography Evaluation in Infants Born Preterm. J Pediatr 2024; 275:114200. [PMID: 39032769 DOI: 10.1016/j.jpeds.2024.114200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Revised: 06/13/2024] [Accepted: 07/15/2024] [Indexed: 07/23/2024]
Affiliation(s)
- Marilena Savoia
- Neonatal Intensive Care Unit, S Maria della Misericordia Hospital, Udine, Italy.
| | - Eva Busolini
- Neonatal Intensive Care Unit, S Maria della Misericordia Hospital, Udine, Italy
| | - Daniel Ibarra Rios
- Division of Neonatology, Instituto Nacional de Perinatología Isidro Espinosa de los Reyes, Ciudad de México, Mexico, Mexico
| | - Brady Thomas
- Division of Neonatology, Department of Pediatrics, University of Iowa, Iowa City, IA
| | - J Lauren Ruoss
- Neonatal Intensive Care Unit, Winnie Palmer Hospital/Orlando Health Regional Hospital, Orlando, Fl
| | - Patrick J McNamara
- Division of Neonatology, Department of Pediatrics, University of Iowa, Iowa City, IA
| |
Collapse
|
5
|
Gross M, Engel C, Esser M, Spogis J, Schäfer JF, Poets CF, Haase B. Lung ultrasound to predict the duration of respiratory support in newborn infants with respiratory distress. Acta Paediatr 2024; 113:2590-2596. [PMID: 39109546 DOI: 10.1111/apa.17377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 07/26/2024] [Indexed: 11/13/2024]
Abstract
AIM Lung ultrasound (LU) and clinical parameters evaluated during the first postnatal hour potentially predict the length of CPAP therapy in newborns with respiratory distress. METHODS In a single-centre, prospective observational pilot study, 130 newborns ≥36 weeks gestational age were assessed using standardised LU at 30 and 60 min postnatally. Various clinical parameters were evaluated influencing CPAP duration (<1 vs. ≥1 h) using univariate and multivariate analyses. RESULTS Lung ultrasound score >5, FiO2 > 0.21 and respiratory acidosis 30 min postnatally were associated with CPAP ≥1 h. Our model showed good diagnostic quality (ROC AUC = 0.87) and was confirmed by classification and regression tree (CART) analysis. Additional LU findings like double lung point and pleural line abnormalities were frequently observed, with good interrater reliability for LU interpretation (ICC = 0.76-0.77). CONCLUSION Newborns with postnatal respiratory distress at risk for prolonged CPAP therapy can be identified based on specific LU and clinical parameters assessed 30 min postnatally. Despite the need for validation in an independent sample, these findings may lay the groundwork for a prediction tool. LU proved feasible and reliable for assessing respiratory status in this population, highlighting potential utility in clinical practice.
Collapse
Affiliation(s)
- Maximilian Gross
- Department of Neonatology, University Children's Hospital Tuebingen, Tuebingen, Germany
| | - Corinna Engel
- Center for Pediatric Clinical Studies, University Children's Hospital Tuebingen, Tuebingen, Germany
| | - Michael Esser
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Jakob Spogis
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Jürgen F Schäfer
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Christian F Poets
- Department of Neonatology, University Children's Hospital Tuebingen, Tuebingen, Germany
| | - Bianca Haase
- Department of Neonatology, University Children's Hospital Tuebingen, Tuebingen, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| |
Collapse
|
6
|
Patel J, Weinberger B, Pulju M, Galanti SG, Kasniya G, Gupta V, Kurepa D. Lung Ultrasound Assessment of Regional Distribution of Pulmonary Edema and Atelectasis in Infants with Evolving Bronchopulmonary Dysplasia. Diagnostics (Basel) 2024; 14:2341. [PMID: 39451663 PMCID: PMC11506572 DOI: 10.3390/diagnostics14202341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Revised: 10/08/2024] [Accepted: 10/14/2024] [Indexed: 10/26/2024] Open
Abstract
Background: Preterm infants are at risk for bronchopulmonary dysplasia (BPD) due to prolonged respiratory support. Studies have described differences in the regional distribution of lung ventilation (non-dependent (NDL) vs. dependent (DL)). The aim of this study was to use LUS to compare regional distribution of pulmonary edema and atelectasis in infants with evolving BPD. Methods: We prospectively performed LUS in premature infants with evolving BPD. On each side, three lung areas (NDL/anterior, lateral, and DL/posterior) were examined for the presence of pulmonary edema and atelectasis. Pulmonary edema scores were assigned based on the number of B-lines, and atelectasis scores were assigned based on the presence/absence of atelectasis. Results: 38 premature infants were enrolled. The NDL showed more pulmonary edema and atelectasis compared to the DL (p = 0.003, p = 0.049, respectively) and compared to the lateral lung (p =< 0.001, p = 0.004, respectively). There was no difference between the lateral and DL (p = 0.188, p = 0.156, respectively). There was no difference between the right and the left lung (p = 0.223, p = 0.656, respectively). Conclusions: In this cohort of preterm infants with evolving BPD, lung disease was unevenly distributed, with more pulmonary edema and atelectasis in the NDL regions compared to the DL or lateral regions.
Collapse
Affiliation(s)
- Jimikumar Patel
- Division of Newborn Medicine, Department of Pediatrics, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216, USA;
| | - Barry Weinberger
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Margaret Pulju
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Stephanie G. Galanti
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Gangajal Kasniya
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Venkata Gupta
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| | - Dalibor Kurepa
- Division of Neonatal-Perinatal Medicine, Northwell Health, Cohen Children’s Medical Center, Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, 269-71 76th Street, New York City, NY 11041, USA; (B.W.); (M.P.); (S.G.G.); (G.K.); (V.G.)
| |
Collapse
|
7
|
Lin X, Zhang H, Wang X, Zhang R, Zhang L, You X, Xiao L, Wu C, Jiang F, Wang J. Proportion of confluent B-Lines predicts respiratory support in term infants shortly after birth. Respir Res 2024; 25:307. [PMID: 39138486 PMCID: PMC11323528 DOI: 10.1186/s12931-024-02944-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Accepted: 08/06/2024] [Indexed: 08/15/2024] Open
Abstract
OBJECTIVE To develop and evaluate the predictive value of a simplified lung ultrasound (LUS) method for forecasting respiratory support in term infants. METHODS This observational, prospective, diagnostic accuracy study was conducted in a tertiary academic hospital between June and December 2023. A total of 361 neonates underwent LUS examination within 1 h of birth. The proportion of each LUS sign was utilized to predict their respiratory outcomes and compared with the LUS score model. After identifying the best predictive LUS sign, simplified models were created based on different scan regions. The optimal simplified model was selected by comparing its accuracy with both the full model and the LUS score model. RESULTS After three days of follow-up, 91 infants required respiratory support, while 270 remained healthy. The proportion of confluent B-lines demonstrated high predictive accuracy for respiratory support, with an area under the curve (AUC) of 89.1% (95% confidence interval [CI]: 84.5-93.7%). The optimal simplified model involved scanning the R/L 1-4 region, yielding an AUC of 87.5% (95% CI: 82.6-92.3%). Both the full model and the optimal simplified model exhibited higher predictive accuracy compared to the LUS score model. The optimal cut-off value for the simplified model was determined to be 15.9%, with a sensitivity of 76.9% and specificity of 91.9%. CONCLUSIONS The proportion of confluent B-lines in LUS can effectively predict the need for respiratory support in term infants shortly after birth and offers greater reliability than the LUS score model.
Collapse
Affiliation(s)
- Xinao Lin
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China
| | - Hehua Zhang
- Department of Neonatology, Fuyang Women and Children's Hospital, Fuyang, China
| | - Xuefeng Wang
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China
| | - Ruijie Zhang
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China
| | - Lu Zhang
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China
| | - Xueqin You
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China
| | - Lingling Xiao
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China
| | - Chuyan Wu
- Department of Rehabilitation Medicine, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Feng Jiang
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China.
| | - Jimei Wang
- Department of Neonatology, Obstetrics and Gynecology Hospital of Fudan University, No. 128, Shenyang Rd, Yangpu District, Shanghai, 200082, China.
| |
Collapse
|
8
|
Pathak KK, Maria A, Guleria M, Mall PK, Sharma A. Association of Lung Ultrasound Scores With Different Modes of Respiratory Support and Clinical Outcomes: An Observational Study in a Tertiary Care Neonatal Unit. Cureus 2024; 16:e66199. [PMID: 39233940 PMCID: PMC11373734 DOI: 10.7759/cureus.66199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/05/2024] [Indexed: 09/06/2024] Open
Abstract
BACKGROUND Lung ultrasound (LUS) is an evolving point-of-care tool in the neonatal intensive care unit. LUS score has been evaluated in adults as well as in neonates to characterize and diagnose various respiratory conditions. Recently, the LUS score has been evaluated for predicting clinical respiratory outcomes in neonates. OBJECTIVE To assess the association between LUS score and various modes of respiratory support and clinical outcomes among neonates presenting with respiratory distress. METHODS In this prospective, cross-sectional, observational study done in a tertiary care neonatal unit, the LUS score was calculated within three hours of receiving respiratory support. Subsequently, the LUS score was assigned with each escalation and de-escalation of respiratory support. Maximum LUS scores for each clinical outcome were also recorded. Inter-rater agreement was determined with the intraclass correlation coefficient. RESULT A total of 162 LUS scans were performed in 65 babies with a mean gestation of 32.4 ± 3.7 weeks and median (IQR) birth weight of 1480 (1130-2000) grams. The LUS scores (median (IQR)) of babies on continuous positive airway pressure (CPAP), noninvasive positive pressure ventilation (NIPPV), and mechanical ventilation (MV) were 4 (3-6.5), 9 (8-11), and 12 (11-13.5), respectively (p-value < 0.001). The difference in maximum median LUS scores between different clinical outcomes was statistically significant, with a p-value < 0.001. LUS score had an excellent inter-rater agreement (intraclass correlation coefficient = 0.998; p-value < 0.001). CONCLUSION There is an association between LUS score and different modes of respiratory support with scores increasing as the level of support increased. LUS score was also found to be related with clinical outcomes like death, extubation failure, and recovery, which could help in predicting the prognosis.
Collapse
Affiliation(s)
- Keshav Kumar Pathak
- Department of Neonatology, All India Institute of Medical Sciences, Patna, Patna, IND
| | - Arti Maria
- Department of Neonatology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, IND
| | - Munish Guleria
- Department of Radiodiagnosis, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, IND
| | - Pranaya Kumar Mall
- Department of Neonatology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, IND
| | - Abhinav Sharma
- Department of Neonatology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, IND
| |
Collapse
|
9
|
Singh Y, Dauengauer-Kirliene S, Yousef N. Setting the Standards: Neonatal Lung Ultrasound in Clinical Practice. Diagnostics (Basel) 2024; 14:1413. [PMID: 39001302 PMCID: PMC11241677 DOI: 10.3390/diagnostics14131413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 06/16/2024] [Accepted: 06/25/2024] [Indexed: 07/16/2024] Open
Abstract
The use of lung ultrasonography in neonates is increasing at a very fast rate. Evidence-based guidelines on the use of lung ultrasound (LU) in neonates and children have been published and well received across the world. However, there remains a lack of standardized curriculum for lung ultrasound training and standards for its application at the bedside. This article focuses on providing a standardized approach to the application of lung ultrasonography in neonates for the common neonatal conditions and how it can be integrated into bedside clinical decision-making.
Collapse
Affiliation(s)
- Yogen Singh
- Department of Pediatrics, Division of Neonatology, UC Davis Children's Hospital, UC Davis Health, Sacramento, CA 95816, USA
| | - Svetlana Dauengauer-Kirliene
- Department of Human and Medical Genetics, Institute of Biomedical Science, Faculty of Medicine, Vilnius University, Santariškių 2, LT-08661 Vilnius, Lithuania
| | - Nadya Yousef
- Division of Pediatrics and Neonatal Critical Care, "A. Béclère" Medical Center, Paris-Saclay University Hospitals, APHP, 92140 Paris, France
| |
Collapse
|
10
|
Szymański P, Puskarz-Gąsowska J, Hożejowski R, Stefańska M, Błaż W, Sadowska-Krawczenko I, Majewska U, Tomaszkiewicz A, Piotrowska M, Kusibab-Mytych M, Słowik-Wasyluk N, Kruczek P, Bokiniec R. Prognostic Relevance of the Lung Ultrasound Score: A Multioutcome Study in Infants with Respiratory Distress Syndrome. Am J Perinatol 2024; 41:e2862-e2869. [PMID: 37848043 PMCID: PMC11150063 DOI: 10.1055/s-0043-1775975] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 08/21/2023] [Indexed: 10/19/2023]
Abstract
OBJECTIVE There is growing evidence for the usefulness of the lung ultrasound score (LUS) in neonatal intensive care. We evaluated whether the LUS is predictive of outcomes in infants with respiratory distress syndrome (RDS). STUDY DESIGN Neonates less than 34 weeks of gestational age were eligible for this prospective, multicenter cohort study. The outcomes of interest were the need for mechanical ventilation (MV) at <72 hours of life, the need for surfactant (SF), successful weaning from continuous positive airway pressure (CPAP), extubation readiness, and bronchopulmonary dysplasia. Lung scans were taken at 0 to 6 hours of life (Day 1), on Days 2, 3, and 7, and before CPAP withdrawal or extubation. Sonograms were scored (range 0-16) by a blinded expert sonographer. The area under the receiver operating characteristic curve (AUC) was used to estimate the prediction accuracy of the LUS. RESULTS A total of 647 scans were obtained from 155 newborns with a median gestational age of 32 weeks. On Day 1, a cutoff LUS of 6 had a sensitivity (Se) of 88% and a specificity (Sp) of 79% to predict the need for SF (AUC = 0.86), while a cutoff LUS of 7 predicted the need for MV at <72 hours of life (Se = 89%, Sp = 65%, AUC = 0.80). LUS acquired prior to weaning off CPAP was an excellent predictor of successful CPAP withdrawal, with a cutoff level of 1 (Se = 67%, Sp = 100%, AUC = 0.86). CONCLUSION The LUS has significant predictive ability for important outcomes in neonatal RDS. KEY POINTS · Lung ultrasound has significant prognostic abilities in neonatal RDS.. · Early sonograms (0-6 h of life) accurately predict the requirement for SF and ventilation.. · Weaning off CPAP is effective when the LUS (range 0-16) is less than or equal to 1..
Collapse
Affiliation(s)
- Piotr Szymański
- Department of Neonatology, Ujastek Medical Center, Cracow, Poland
- Department of Neonatology, Czerwiakowski Hospital at Siemiradzki St., Cracow, Poland
| | | | | | - Małgorzata Stefańska
- Department of Neonatal and Intensive Care, F. Chopin District Specialist Hospital, Rzeszów, Poland
| | - Witold Błaż
- Department of Neonatal and Intensive Care, Rzeszów Provincial Hospital No. 2, Rzeszów, Poland
- Faculty of Medicine, University of Rzeszów, Rzeszów, Poland
| | | | - Urszula Majewska
- Department of Neonatal and Intensive Care, Medical University of Warsaw, Warsaw, Poland
| | - Anna Tomaszkiewicz
- Department of Neonatology, Ujastek Medical Center, Cracow, Poland
- Department of Neonatal and Intensive Care, Rzeszów Provincial Hospital No. 2, Rzeszów, Poland
| | | | - Marta Kusibab-Mytych
- Department of Neonatal and Intensive Care, F. Chopin District Specialist Hospital, Rzeszów, Poland
| | - Natalia Słowik-Wasyluk
- Department of Neonatal and Intensive Care, Rzeszów Provincial Hospital No. 2, Rzeszów, Poland
| | - Piotr Kruczek
- Department of Neonatology, Ujastek Medical Center, Cracow, Poland
- Department of Neonatology, Czerwiakowski Hospital at Siemiradzki St., Cracow, Poland
| | - Renata Bokiniec
- Department of Neonatal and Intensive Care, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
11
|
Ozdemir M, Tepe T, Ozlu F, Yapicioglu H, Atmıs A, Demir F, Unal I, Narli N. Lung ultrasound score in the decision of patent ductus arteriosus closure in neonates. JOURNAL OF CLINICAL ULTRASOUND : JCU 2024; 52:415-425. [PMID: 38385619 DOI: 10.1002/jcu.23653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/05/2024] [Accepted: 02/10/2024] [Indexed: 02/23/2024]
Abstract
PURPOSE We aimed to investigate the role of lung ultrasound (LUS) score in the closure of hemodynamically insignificant patent ductus arteriosus (PDA) and the clinical findings of the patients before and after closure. METHODS The study groups (107 preterm neonates under 34 gestational weeks) were classified as hemodynamically significant PDA (group 1), hemodynamically insignificant PDA with closure therapy (group 2), hemodynamically insignificant PDA without closure therapy (group 3), and no PDA group (group 4) based on the echocardiography. 6- and 10-region LUS scores were compared for each group. RESULTS There was a significant difference between groups 1 and 3 on first, third, and seventh days. In contrast, groups 1 and 2 had similar LUS scores on the first, third, and seventh days. There was a negative correlation between LUS scores on the first and third days and gestational age, birth weight, the first- and fifth-minute APGAR scores, and there was a positive correlation between aortic root to left atrium ratio, and PDA diameter/weight ratio. CONCLUSION We observed that LUS scores in patients with hemodynamically insignificant PDA treated with closure therapy were similar to in patients with hemodynamically significant PDA. Thus, LUS score can have role in PDA closure in preterm neonates. However, more comprehensive studies are needed.
Collapse
Affiliation(s)
- Mustafa Ozdemir
- Faculty of Medicine, Department of Pediatrics, Division of Neonatology, Cukurova University, Adana, Turkey
| | - Tugay Tepe
- Faculty of Medicine, Department of Pediatrics, Division of Neonatology, Cukurova University, Adana, Turkey
| | - Ferda Ozlu
- Faculty of Medicine, Department of Pediatrics, Division of Neonatology, Cukurova University, Adana, Turkey
| | - Hacer Yapicioglu
- Faculty of Medicine, Department of Pediatrics, Division of Neonatology, Cukurova University, Adana, Turkey
| | - Anıl Atmıs
- Faculty of Medicine, Department of Pediatrics, Division of Pediatric Cardiology, Cukurova University, Adana, Turkey
| | - Fadli Demir
- Faculty of Medicine, Department of Pediatrics, Division of Pediatric Cardiology, Cukurova University, Adana, Turkey
| | - Ilker Unal
- Faculty of Medicine, Department of Biostatistics, Cukurova University, Adana, Turkey
| | - Nejat Narli
- Faculty of Medicine, Department of Pediatrics, Division of Neonatology, Cukurova University, Adana, Turkey
| |
Collapse
|
12
|
Zong H, Huang Z, Fu Y, Chen X, Yu Y, Huang Y, Huang Y, Sun H, Yang C. Lung ultrasound score as a tool to predict severity of bronchopulmonary dysplasia in neonates born ≤25 weeks of gestational age. J Perinatol 2024; 44:273-279. [PMID: 38087005 DOI: 10.1038/s41372-023-01811-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/13/2023] [Accepted: 10/18/2023] [Indexed: 02/07/2024]
Abstract
OBJECTIVE The primary aim was to evaluate whether the addition of the posterior lung aided in diagnostic accuracy of predicting bronchopulmonary dysplasia (BPD) vs moderate-severe BPD (msBPD); the secondary aim was to explore the diagnostic accuracy of two protocols for BPD vs msBPD. STUDY DESIGN This was a single-center prospective observational study. Preterm infants with a gestational age ≤ 25 weeks were included. Two LUS score protocols were evaluated on the 14th day of life (DOL): (A) evaluating the anterolateral (LUS score-al) lung and (B) the anterolateral combined with posterior (LUS score-alp) lung. The LUS score range for the two protocols was 0-32 and 0-48, respectively. RESULTS A total of eighty-nine infants were enrolled. Both the LUS score-al and LUS score-alp were higher in neonates developing BPD and msBPD than in the rest of the cohort (LUS score-al 24 (23,26) vs 22 (20,23); LUS score-alp 36 (34,39) vs 28 (25,32)) (LUS score-al 25 (24,26) vs 23 (21,24); LUS score-alp 40 (39,40) vs 34 (28,36)). The LUS score-al on the 14th DOL showed a moderate diagnostic accuracy to predict BPD and msBPD (AUC 95% CI: 0.797 [0.697-0.896]; 0.811[0.713-0.909]), while the LUS score-alp significantly improved diagnostic accuracy of BPD and msBPD (AUC 95% CI: 0.902 [0.834-0.970]; 0.922 [0.848-0.996]). A cutoff of 25 points in the LUS score-al provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 76.9%, 79.4%, 3.7, and 0.3 respectively to predict msBPD. Meanwhile, that of 39 points in the LUS score-alp provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 81%, 98.4%, 50.5 and 0.19 to predict msBPD, respectively. CONCLUSIONS The LUS score on the 14th DOL can predict BPD and msBPD with moderate diagnostic accuracy. Apart from that, scanning posterior enhanced diagnostic accuracy.
Collapse
Affiliation(s)
- Haifeng Zong
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Zhifeng Huang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Yongping Fu
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Xueyu Chen
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Yanliang Yu
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Yingsui Huang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Yichu Huang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Hongyan Sun
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China
| | - Chuanzhong Yang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, 518028, China.
| |
Collapse
|
13
|
Liu J. Ultrasound diagnosis and grading criteria of neonatal respiratory distress syndrome. J Matern Fetal Neonatal Med 2023; 36:2206943. [PMID: 37142428 DOI: 10.1080/14767058.2023.2206943] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 04/20/2023] [Indexed: 05/06/2023]
Abstract
Background: Respiratory distress syndrome (RDS) is a common critical lung disease in newborn infants, especially those in premature infants with higher mortality rate. Early and correct diagnosis is the key to improve its prognosis. Previously, the diagnosis of RDS mainly relied on chest X-ray (CXR) findings, and it has been graded into four stages based on the progression and severity of CXR changes. This traditional diagnosing and grading method may lead to high misdiagnosis rate or delayed diagnosis. Recently, using ultrasound to diagnose neonatal lung diseases and RDS is becoming increasingly popular, and the technology is gaining higher sensitivity and higher specificity. The management of RDS under lung ultrasound (LUS) monitoring has achieved significant results, reducing the misdiagnosis rate of RDS, thereby reducing the probability of mechanical ventilation and the use of exogenous pulmonary surfactant, and making the success rate of treatment of RDS up to 100%.Objective: The purpose of the article was to introduce the ultrasound grading methods and criteria of RDS, in order to promote the application of LUS in the diagnosis and treatment of RDS.Methods: Literature (in English and Chinese) on the use of ultrasound in the diagnosis of neonatal RDS between 2008 and 2022 was selected for inclusion in this study.Results: From the collected literature, the use of ultrasound in the diagnosis of RDS is increasing, and people's understanding of the ultrasound imaging findings of RDS is also changing. Among them, the research on ultrasound grading of RDS is the latest progress.Conclusion: Ultrasound is accurate and reliable in the diagnosis and differential diagnosis of RDS. It is of great clinical value to master the ultrasound diagnosis and grading criteria of RDS.
Collapse
Affiliation(s)
- Jing Liu
- Department of Neonatology and NICU, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
14
|
Mohsen N, Solis-Garcia G, Jasani B, Nasef N, Mohamed A. Accuracy of lung ultrasound in predicting extubation failure in neonates: A systematic review and meta-analysis. Pediatr Pulmonol 2023; 58:2846-2856. [PMID: 37431954 DOI: 10.1002/ppul.26598] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 06/06/2023] [Accepted: 07/03/2023] [Indexed: 07/12/2023]
Abstract
OBJECTIVE To systematically review and meta-analyze the diagnostic accuracy of lung ultrasound score (LUS) in predicting extubation failure in neonates. STUDY DESIGN MEDLINE, COCHRANE, EMBASE, CINAHL, and clinicaltrials.gov were searched up to 30 November 2022, for studies evaluating the diagnostic accuracy of LUS in predicting extubation outcome in mechanically ventilated neonates. METHODOLOGY Two investigators independently assessed study eligibility, extracted data, and assessed study quality using the Quality Assessment for Studies of Diagnostic Accuracy 2 tool. We conducted a meta-analysis of pooled diagnostic accuracy data using random-effect models. Data were reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We calculated pooled sensitivity and specificity, pooled diagnostic odds ratios with 95% confidence intervals (CI), and area under the curve (AUC). RESULTS Eight observational studies involving 564 neonates were included, and the risk of bias was low in seven studies. The pooled sensitivity and specificity for LUS in predicting extubation failure in neonates were 0.82 (95% CI: 0.75-0.88) and 0.83 (95% CI: 0.78-0.86), respectively. The pooled diagnostic odds ratio was 21.24 (95% CI: 10.45-43.19), and the AUC for LUS predicting extubation failure was 0.87 (95% CI: 0.80-0.95). Heterogeneity among included studies was low, both graphically and by statistical criteria (I2 = 7.35%, p = 0.37). CONCLUSIONS The predictive value of LUS in neonatal extubation failure may hold promise. However, given the current level of evidence and the methodological heterogeneity observed, there is a clear need for large-scale, well-designed prospective studies that establish standardized protocols for lung ultrasound performance and scoring. REGISTRATION The protocol was registered in OSF (https://doi.org/10.17605/OSF.IO/ZXQUT).
Collapse
Affiliation(s)
- Nada Mohsen
- Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Gonzalo Solis-Garcia
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada
- The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Bonny Jasani
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada
- The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Nehad Nasef
- Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Adel Mohamed
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada
- Mount Sinai Hospital, Toronto, Ontario, Canada
| |
Collapse
|
15
|
Use of Cardio-Pulmonary Ultrasound in the Neonatal Intensive Care Unit. CHILDREN 2023; 10:children10030462. [PMID: 36980020 PMCID: PMC10047372 DOI: 10.3390/children10030462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/11/2023] [Accepted: 02/22/2023] [Indexed: 03/03/2023]
Abstract
Cardiopulmonary ultrasound (CPUS), the combination of lung ultrasound (LUS) and targeted neonatal echocardiography (TnECHO)AA, may offer a more appropriate approach to the challenging neonatal cardiovascular and respiratory disorders. This paper reviews the possible use of CPUS in the neonatal intensive care unit (NICU).
Collapse
|
16
|
Savoia M, Miletic P, De Martino M, Morassutti FR. Lung ultrasound score follows the chronic pulmonary insufficiency of prematurity trajectory in early infancy. Eur J Pediatr 2022; 181:4157-4166. [PMID: 36166097 DOI: 10.1007/s00431-022-04629-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 09/05/2022] [Accepted: 09/16/2022] [Indexed: 11/29/2022]
Abstract
Extremely preterm birth is associated with a high risk of chronic pulmonary insufficiency of prematurity (CPIP). Lung ultrasound score (LUS) proved capable to characterise CPIP progression beyond the acute setting, but still, post-discharge data remain lacking. We hypothesised a priori that LUS in both BPD and no-BPD infants declines with postnatal age from birth through early infancy. This observational retrospective cohort study included preterm infants < 32 gestational weeks, who underwent the follow-up for CPIP. LUS was assessed from birth to 8 months postnatal age, over antero-lateral (LUS) and posterior (pLUS) pulmonary areas, placing the transducer longitudinally over the midclavicular and midaxillary lines and medial to the scapular line respectively. Extended LUS (eLUS) including LUS and pLUS was calculated. The primary outcome was LUS time course. Secondary outcomes included the correlation between LUS and pLUS. Sixty-two infants were included: 22 (35.5%) in the BPD group and 40 (64.5%) in the no-BPD group. BPD group infants were smaller (weight 841 g (± 228) vs 1226 (± 328), p < 0.001) and younger (26.8 weeks (± 2.0) vs 28.9 (± 1.9), p < 0.001). LUS declined over time in the entire population (ß = - 1.75, p < 0.001) and in both no-BPD and BPD groups (ß = - 1.64, p < 0.001 and ß = - 1.93, p < 0.001, respectively). eLUS declined correspondingly (p < 0.001). LUS and likewise eLUS were significantly different between BPD and no-BPD groups over time (p < 0.001). Conclusion: LUS trajectory progressively decreased from birth to early infancy. BPD cohort tracked higher, implying a worse respiratory status. pLUS had a similar timepoint course, adding no further information to LUS. To the best of our knowledge, this is the first study that describes preterm LUS time course after discharge. LUS may help track the CPIP progression. What is Known: • Extremely preterm birth is associated with high risk of chronic pulmonary insufficiency of prematurity (CPIP). • Several studies investigated the ability of lung ultrasound score (LUS) to characterize CPIP progression beyond the acute setting, still post-discharge data remain lacking. What is New: • LUS trajectory progressively decreases from birth to early infancy; BPD cohort tracks higher, implying a worse respiratory status. pLUS has similar timepoint course, adding no further information to LUS. • The use of LUS may contribute to better characterising and monitoring CPIP in BPD and no-BPD infants.
Collapse
Affiliation(s)
- Marilena Savoia
- Neonatal Intensive Care Unit, Santa Maria Della Misericordia Hospital, Piazzale Santa Maria della Misericordia, 15, 33100, Udine, Italy.
| | - Patrik Miletic
- Neonatal Intensive Care Unit, Santa Maria Della Misericordia Hospital, Piazzale Santa Maria della Misericordia, 15, 33100, Udine, Italy
| | - Maria De Martino
- Division of Medical Statistic, University of Udine, Udine, Italy
| | - Francesca Rech Morassutti
- Neonatal Intensive Care Unit, Santa Maria Della Misericordia Hospital, Piazzale Santa Maria della Misericordia, 15, 33100, Udine, Italy
| |
Collapse
|
17
|
Stewart DL, Elsayed Y, Fraga MV, Coley BD, Annam A, Milla SS. Use of Point-of-Care Ultrasonography in the NICU for Diagnostic and Procedural Purposes. Pediatrics 2022; 150:190110. [PMID: 37154781 DOI: 10.1542/peds.2022-060053] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/26/2022] [Indexed: 11/29/2022] Open
Abstract
Point-of-care ultrasonography (POCUS) refers to the use of portable imaging performed by the provider clinician at the bedside for diagnostic, therapeutic, and procedural purposes. POCUS could be considered an extension of the physical examination but not a substitute for diagnostic imaging. Use of POCUS in emergency situations can be lifesaving in the NICU if performed in a timely fashion for cardiac tamponade, pleural effusions, pneumothorax, etc, with potential for enhancing quality of care and improving outcomes.
In the past 2 decades, POCUS has gained significant acceptance in clinical medicine in many parts of the world and in many subspecialties. Formal accredited training and certification programs are available for neonatology trainees as well as for many other subspecialties in Canada, Australia, and New Zealand. Although no formal training program or certification is available to neonatologists in Europe, POCUS is widely available to providers in NICUs. A formal institutional POCUS fellowship is now available in Canada. In the United States, many clinicians have the skills to perform POCUS and have incorporated it in their daily clinical practice. However, appropriate equipment remains limited, and many barriers exist to POCUS program implementation.
Recently, the first international evidence-based POCUS guidelines for use in neonatology and pediatric critical care were published. Considering the potential benefits, a recent national survey of neonatologists confirmed that the majority of clinicians were inclined to adopt POCUS in their clinical practice if the barriers could be resolved.
This technical report describes many potential POCUS applications in the NICU for diagnostic and procedural purposes.
Collapse
Affiliation(s)
- Dan L Stewart
- Department of Pediatrics and International Pediatrics, Norton Children's Neonatology Affiliated with University of Louisville School of Medicine, Louisville, Kentucky
| | - Yasser Elsayed
- Department of Pediatrics and Child Health, Max Rady College of Medicine, University of Manitoba-Canada, Health Sciences Centre-Winnipeg, Winnipeg, Manitoba, Canada
| | - María V Fraga
- Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania
| | - Brian D Coley
- Departments of Radiology and Pediatrics, University of Cincinnati College of Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| | - Aparna Annam
- Departments of Radiology and Pediatrics, University of Colorado School of Medicine, Children's Hospital Colorado, Vascular Anomalies Center, Aurora, Colorado
| | - Sarah Sarvis Milla
- Departments of Radiology and Pediatrics, University of Colorado School of Medicine, Children's Hospital Colorado, Aurora, Colorado
| |
Collapse
|
18
|
Elsayed Y, Narvey M, Lashin A, Alammary D, Gigolyk S, Louis D. Point of care lung ultrasound service in neonatal intensive care: Five years of experience in Manitoba, Canada. J Perinatol 2022; 42:1228-1232. [PMID: 35831578 DOI: 10.1038/s41372-022-01455-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 05/04/2022] [Accepted: 06/30/2022] [Indexed: 12/14/2022]
Abstract
OBJECTIVE To evaluate the utility of a point of care lung ultrasound (POC-LUS) on patient management in the Neonatal Intensive Care Unit (NICU). STUDY DESIGN A retrospective cohort study of neonates who had POC-LUS from 2016 to 2020 in two-level III NICUs in Winnipeg, Manitoba, Canada. The primary outcome was the change in clinical management. The analysis aims mainly to describe the implementation process of the POC-LUS program. RESULTS A total of 956 neonates underwent 4076 POC-LUS studies during the study period. The number of POC-LUS studies increased significantly every year, from 316 (in 2016) to 1257 (in 2020) (p < 0.001). POC-LUS resulted in a change in clinical management following 2528 POC-LUS studies (62%), while it supported continuing the same management in 1548 studies (38%). CONCLUSION POC-LUS in Manitoba increased since its inception and led to an alteration in the clinical management in a significant proportion of patients who received the service.
Collapse
Affiliation(s)
- Yasser Elsayed
- Division of Neonatology, Department of Pediatrics and Child Health, Rady Faculty of Medicine, University of Manitoba, Winnipeg, Canada.
| | - Michael Narvey
- Division of Neonatology, Department of Pediatrics and Child Health, Rady Faculty of Medicine, University of Manitoba, Winnipeg, Canada
| | - Asem Lashin
- Division of Neonatology, Department of Pediatrics and Child Health, Rady Faculty of Medicine, University of Manitoba, Winnipeg, Canada
| | - Deima Alammary
- Division of Neonatology, Department of Pediatrics and Child Health, Rady Faculty of Medicine, University of Manitoba, Winnipeg, Canada
| | - Shere Gigolyk
- Department of respiratory therapy, St Boniface hospital, Winnipeg, Canada
| | - Deepak Louis
- Division of Neonatology, Department of Pediatrics and Child Health, Rady Faculty of Medicine, University of Manitoba, Winnipeg, Canada
| |
Collapse
|
19
|
Hoshino Y, Arai J, Miura R, Takeuchi S, Yukitake Y, Kajikawa D, Kamakura T, Horigome H. Lung Ultrasound for Predicting the Respiratory Outcome in Patients with Bronchopulmonary Dysplasia. Am J Perinatol 2022; 39:1229-1235. [PMID: 33374021 DOI: 10.1055/s-0040-1721848] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVE This study aimed to investigate the utility of lung ultrasound (LUS) with whole chest scanning for predicting respiratory outcomes in patients with bronchopulmonary dysplasia (BPD). STUDY DESIGN We performed a prospective observational study. Preterm infants of less than 32 weeks' gestational age requiring oxygen therapy at 28 days of life were included. LUS was performed on day 28, at 36 weeks' postmenstrual age, and at the time of discharge. Each lung was divided into three regions by the anterior and posterior axillary lines and received an LUS score of 0 to 3 points; the total score was obtained by adding the six regional scores. The classification of BPD was determined based on the National Institute of Child and Human Development. The outcomes of this study were the development of moderate-to-severe BPD and the need for home oxygen therapy (HOT). RESULTS We enrolled 87 patients; 39, 33, and 15 infants had mild, moderate, and severe BPD, respectively. The LUS score correlated with BPD severity and exhibited an improvement trend with time toward the point of discharge. LUS at 28 days of life predicted moderate-to-severe BPD with an area under the curve of 0.95 (95% confidence interval: 0.91-0.99) and HOT with an area under the curve of 0.95 (95% confidence interval: 0.81-1.0). CONCLUSION LUS with whole chest scanning is useful for predicting respiratory outcomes in patients with BPD, as well as for understanding BPD severity or clinical improvement trends. KEY POINTS · LUS predicts respiratory outcomes in patients with BPD.. · LUS indicates BPD severity.. · LUS can show clinical improvement with time..
Collapse
Affiliation(s)
- Yusuke Hoshino
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Junichi Arai
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Rena Miura
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Syusuke Takeuchi
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Yoshiya Yukitake
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Daigo Kajikawa
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Tae Kamakura
- Department of Neonatology, Ibaraki Children's Hospital, Mito, Japan
| | - Hitoshi Horigome
- Department of Child Health, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan
| |
Collapse
|
20
|
Alonso-Ojembarrena A, Méndez-Abad P, Alonso-Quintela P, Zafra-Rodríguez P, Oulego-Erroz I, Lubián-López SP. Lung ultrasound score has better diagnostic ability than NT-proBNP to predict moderate-severe bronchopulmonary dysplasia. Eur J Pediatr 2022; 181:3013-3021. [PMID: 35648231 DOI: 10.1007/s00431-022-04491-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/27/2022] [Accepted: 04/29/2022] [Indexed: 11/24/2022]
Abstract
UNLABELLED The N-terminal end of B-type natriuretic peptide (NT-proBNP) and lung ultrasound (LUS) score have been proven to be adequate early biomarkers of bronchopulmonary dysplasia (BPD) in preterm infants. Our aim was to study if the predictive capacity of each one is increased by analyzing them together. We included infants born before 32 weeks with NT-proBNP and LUS scores on the first day of life (DOL) and on the 3rd, 7th, and 14th DOL and compared the diagnostic ability for moderate-severe BPD (msBPD) of each biomarker and in combination. We also compared them with a multivariate model of msBPD using only clinical variables. The sample size was 133 patients, and twenty-seven (20%) developed msBPD. The LUS score on the 7th DOL had better performance than NT-proBNP at the same moment: area under the receiver operating characteristic curve (AUC) 0.83 (0.75-0.89) versus 0.66 (0.56-0.75), p = 0.003, without differences in the rest of the times studied. These values did not increase when using the combination of both. A multivariate regression model that included only clinical variables (birth weight and invasive mechanical ventilation (IMV) at the 7th DOL) predicted msBPD with the same AUC as after the addition of any of these biomarkers, neither together. CONCLUSION The LUS score is a better predictor of msBPD on the 7th DOL than NT-proBNP in preterm infants born before 32 weeks, although they have similar diagnostic accuracy on the 1st, 3rd, and 14th DOL. Neither of them, nor together, have a better AUC for msBPD than a clinical model with birthweight and the need for IMV at the 7th DOL. WHAT IS KNOWN • NT-proBNP and LUS score are early predictors of moderate-severe bronchopulmonary dysplasia (msBPD). WHAT IS NEW • The combination of both NT-proBNP and LUS score does not increase the predictive ability of each separately.
Collapse
Affiliation(s)
- Almudena Alonso-Ojembarrena
- Neonatal Intensive Care Unit, Puerta del Mar Universitary Hospital, Avenida Ana de Viya 11, 11010, Cádiz, Spain. .,Biomedical Research and Innovation Institute of Cádiz (INiBICA), Research Unit, Puerta del Mar University Hospital, Cádiz, Spain.
| | - Paula Méndez-Abad
- Neonatal Intensive Care Unit, Puerta del Mar Universitary Hospital, Avenida Ana de Viya 11, 11010, Cádiz, Spain.,Biomedical Research and Innovation Institute of Cádiz (INiBICA), Research Unit, Puerta del Mar University Hospital, Cádiz, Spain
| | - Paula Alonso-Quintela
- Neonatal Intensive Care Unit, Complejo Asistencial Universitario de León, León, Spain.,Biomedicine Institute of León (IBIOMED), University of León, León, Spain
| | - Pamela Zafra-Rodríguez
- Neonatal Intensive Care Unit, Puerta del Mar Universitary Hospital, Avenida Ana de Viya 11, 11010, Cádiz, Spain.,Biomedical Research and Innovation Institute of Cádiz (INiBICA), Research Unit, Puerta del Mar University Hospital, Cádiz, Spain
| | - Ignacio Oulego-Erroz
- Biomedicine Institute of León (IBIOMED), University of León, León, Spain.,Pediatric Intensive Care Unit, Complejo Asistencial Universitario de León, León, Spain.,Working Group On Bedside Ultrasound of the Spanish Society of Pediatric Intensive Care (SECIP), Madrid, Spain
| | - Simón P Lubián-López
- Neonatal Intensive Care Unit, Puerta del Mar Universitary Hospital, Avenida Ana de Viya 11, 11010, Cádiz, Spain.,Biomedical Research and Innovation Institute of Cádiz (INiBICA), Research Unit, Puerta del Mar University Hospital, Cádiz, Spain.,Department of Maternal and Child Health and Radiology, School of Medicine, University of Cádiz, Cádiz, Spain
| |
Collapse
|
21
|
McGillick EV, te Pas AB, van den Akker T, Keus JMH, Thio M, Hooper SB. Evaluating Clinical Outcomes and Physiological Perspectives in Studies Investigating Respiratory Support for Babies Born at Term With or at Risk of Transient Tachypnea: A Narrative Review. Front Pediatr 2022; 10:878536. [PMID: 35813383 PMCID: PMC9260080 DOI: 10.3389/fped.2022.878536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 05/09/2022] [Indexed: 12/02/2022] Open
Abstract
Respiratory distress in the first few hours of life is a growing disease burden in otherwise healthy babies born at term (>37 weeks gestation). Babies born by cesarean section without labor (i.e., elective cesarean section) are at greater risk of developing respiratory distress due to elevated airway liquid volumes at birth. These babies are commonly diagnosed with transient tachypnea of the newborn (TTN) and historically treatments have mostly focused on enhancing airway liquid clearance pharmacologically or restricting fluid intake with limited success. Alternatively, a number of clinical studies have investigated the potential benefits of respiratory support in newborns with or at risk of TTN, but there is considerable heterogeneity in study designs and outcome measures. A literature search identified eight clinical studies investigating use of respiratory support on outcomes related to TTN in babies born at term. Study demographics including gestational age, mode of birth, antenatal corticosteroid exposure, TTN diagnosis, timing of intervention (prophylactic/interventional), respiratory support (type/interface/device/pressure), and study outcomes were compared. This narrative review provides an overview of factors within and between studies assessing respiratory support for preventing and/or treating TTN. In addition, we discuss the physiological understanding of how respiratory support aids lung function in newborns with elevated airway liquid volumes at birth. However, many questions remain regarding the timing of onset, pressure delivered, device/interface used and duration, and weaning of support. Future studies are required to address these gaps in knowledge to provide evidenced based recommendations for management of newborns with or at risk of TTN.
Collapse
Affiliation(s)
- Erin V. McGillick
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, Monash University, Melbourne, VIC, Australia
| | - Arjan B. te Pas
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, Netherlands
| | - Thomas van den Akker
- Department of Obstetrics and Gynaecology, Leiden University Medical Center, Leiden, Netherlands
- Athena Institute, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - J. M. H. Keus
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, Netherlands
| | - Marta Thio
- Newborn Research, The Royal Women’s Hospital, Melbourne, VIC, Australia
- The Murdoch Children’s Research Institute, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, University of Melbourne, Melbourne, VIC, Australia
| | - Stuart B. Hooper
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
22
|
Alonso-Ojembarrena A, Raimondi F. The meaning of gravity-induced lung ultrasound score variations. J Perinatol 2022; 42:289. [PMID: 34845297 DOI: 10.1038/s41372-021-01280-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/05/2021] [Accepted: 11/16/2021] [Indexed: 11/09/2022]
Affiliation(s)
- A Alonso-Ojembarrena
- Neonatal Intensive Care Unit, Puerta del Mar University Hospital, Cádiz, Spain. .,Research Unit, Biomedical Research and Innovation Institute of Cádiz (INiBICA), Puerta del Mar University Hospital, Cádiz, Spain.
| | - F Raimondi
- Division of Neonatology, Department of Translational Medical Sciences, Università "Federico II", Naples, Italy
| |
Collapse
|
23
|
Ibarra-Ríos D, Enríquez-Estrada AC, Serpa-Maldonado EV, Miranda-Vega AL, Villanueva-García D, Vázquez-Solano EP, Márquez-González H. Lung Ultrasound Characteristics in Neonates With Positive Real Time Polymerase Chain Reaction for SARS-CoV-2 on a Tertiary Level Referral Hospital in Mexico City. Front Pediatr 2022; 10:859092. [PMID: 35463891 PMCID: PMC9033263 DOI: 10.3389/fped.2022.859092] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 02/24/2022] [Indexed: 11/29/2022] Open
Abstract
INTRODUCTION Acute respiratory syndrome secondary to SARS-CoV-2 virus infection has been declared a pandemic since December 2019. On neonates, severe presentations are infrequent but possible. Lung ultrasound (LUS) has been shown to be useful in diagnosing lung involvement and following up patients, giving more information, and reducing exposure compared to traditional examination. METHODS LUS was performed after the diagnosis of SARS-CoV-2 infection with respiratory Real Time Polymerase Chain Reaction RT-PCR with portable equipment protected with a silicone sleeve. If hemodynamic or cardiology consultation was necessary, a prepared complete ultrasound machine was used. Ten regions were explored (anterior superior and inferior, lateral, and posterior superior and inferior, right and left), and a semiquantitative score (LUSS) was calculated. Disease severity was determined with a pediatric modified score. RESULTS Thirty-eight patients with positive RT-PCR were admitted, 32 (81%) of which underwent LUS. Included patients had heterogenous diagnosis and gestational ages as expected on a referral neonatal intensive care unit (NICU) (median, ICR: 36, 30-38). LUS abnormalities found were B-line interstitial pattern 90%, irregular/interrupted/thick pleural line 88%, compact B-lines 65%, small consolidations (≤5 mm) 34%, and extensive consolidations (≥5 mm) 37%. Consolidations showed posterior predominance (70%). LUSS showed a median difference between levels of disease severity and ventilatory support (Kruskal-Wallis, p = 0.001) and decreased with patient improvement (Wilcoxon signed-rank test p = 0.005). There was a positive correlation between LUSS and FiO2 needed (Spearman r = 0.72, p = 0.01). The most common recommendation to the attending team was pronation (41%) and increase in positive end expiratory pressure (34%). Five patients with comorbidities died. A significant rank difference of LUSS and FiO2 needed between survivors and non-survivors was found (Mann-Whitney U-test, p = 0.005). CONCLUSION LUS patterns found were like the ones described in other series (neonatal and pediatrics). Eighty-eight percent of the studies were performed with handheld affordable equipment. While there is no specific pattern, it varies according to gestational age and baseline diagnosis LUS, which were shown to be useful in assessing lung involvement that correlated with the degree of disease severity and respiratory support.
Collapse
Affiliation(s)
- Daniel Ibarra-Ríos
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | | | | | - Ana Luisa Miranda-Vega
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | - Dina Villanueva-García
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | - Edna Patricia Vázquez-Solano
- Neonatology Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| | - Horacio Márquez-González
- Clinical Investigation Department, National Institutes of Health, Hospital Infantil de México Federico Gómez, Mexico City, Mexico
| |
Collapse
|
24
|
Gravity-induced loss of aeration and atelectasis development in the preterm lung: a serial sonographic assessment. J Perinatol 2022; 42:231-236. [PMID: 34417561 PMCID: PMC8377153 DOI: 10.1038/s41372-021-01189-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 07/29/2021] [Accepted: 08/10/2021] [Indexed: 12/17/2022]
Abstract
OBJECTIVE To assess the impact of gravity and time on the changes in the distribution patterns of loss of aeration and atelectasis development in very preterm infants. STUDY DESIGN Preterm infants less than 32 weeks gestation were included in this prospective, observational study. Infants were assessed via serial lung ultrasound (LUS) score in four lung zones, performed on days 7, 14, 21, and 28 after birth. RESULT Eighty-eight patients were enrolled. There was a significant main effect of gravity (P < 0.001) and time (P = 0.01) on the LUS score between gravity-dependent lungs and non-dependent lungs. Moreover, there was a significant main effect of gravity (P = 0.003) on atelectasis development between the lungs. CONCLUSION Gravity and time have an impact on the changes in the distribution patterns of gravity-induced lung injuries in preterm infants.
Collapse
|
25
|
Meta-analysis of Lung Ultrasound Scores for Early Prediction of Bronchopulmonary Dysplasia. Ann Am Thorac Soc 2021; 19:659-667. [PMID: 34788582 DOI: 10.1513/annalsats.202107-822oc] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
RATIONALE Lung ultrasound scores (LUS) might be useful in monitoring neonates with chronic pulmonary insufficiency of prematurity and in predicting bronchopulmonary dysplasia (BPD). Given their ease of use, accuracy and lack of invasiveness, LUS have been the subject of several recent studies. OBJECTIVE We sought to clarify whether LUS provide an accurate and early (within the first two weeks of life) prediction of BPD in preterm infants of gestational age <32weeks. METHODS Systematic review and diagnostic accuracy meta-analysis following PRISMA-P, PRISMA and QUADAS guidelines. Studies designed to predict BPD in the first two weeks of life using LUS were selected. A classical LUS (calculated for 6 chest areas) and its extended version (eLUS, 10 chest areas) were tested. RESULTS Seven studies (1027 neonates) were meta-analyzed. LUS and eLUS showed good diagnostic accuracy in predicting BPD at 7 and 14 days of life (AUC 0.85-0.87, pooled sensitivity 70-80%, pooled specificity 80-87%). The diagnostic accuracy of LUS and eLUS did not differ at any timepoint (AUC difference always p >0.05). Repeating the analyses without outliers or with moderate-to-severe BPD as outcome yielded similar results. Meta-regressions showed that prenatal steroid prophylaxis and sex were not significant effect confounders. CONCLUSIONS LUS are accurate for early prediction of BPD and moderate-to-severe BPD, in an average population of preterm infants <32weeks' gestation. The diagnostic accuracy is similar for LUS and eLUS, so the use of the simpler score should be advocated. Registration. PROSPERO CRD42021233010.
Collapse
|
26
|
Lung Ultrasound for Prediction of Bronchopulmonary Dysplasia in Extreme Preterm Neonates: A Prospective Diagnostic Cohort Study. J Pediatr 2021; 238:187-192.e2. [PMID: 34237347 DOI: 10.1016/j.jpeds.2021.06.079] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 06/24/2021] [Accepted: 06/29/2021] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To evaluate the diagnostic and predictive ability of lung ultrasound at 3 time points in the first 2 weeks after birth for predicting bronchopulmonary dysplasia (BPD) among infants <29 weeks of gestational age. STUDY DESIGN This was a prospective, diagnostic cohort study. Lung ultrasound was performed on days 3, 7, and 14 after birth and lung ultrasound scores (LUS) were calculated in blinded fashion. Diagnostic test characteristics and area under receiver operating characteristic (AUROC) curves were calculated. RESULTS A total of 152 infants were enrolled with mean (SD) gestational age of 25.8 (1.5) weeks gestation. Of them, 87 (57%) infants were diagnosed with BPD. The LUS were significantly higher in infants diagnosed with BPD compared with those without BPD at all scan time points (P < .01). The score of >10 at all 3 time points had higher sensitivity (0.89, 0.89, and 0.77), specificity (0.87, 0.90, and 0.92), and corresponding clinically important positive and negative likelihood ratios. The AUROC for LUS at the 3 time points were 0.96, 0.97, and 0.95 on day 3, 7, and 14, respectively. Compared with the model using clinical characteristics, LUS alone had higher AUROC (P < .05 for all 3 time points). CONCLUSIONS In this cohort, LUS in the first 2 weeks after birth had a very high predictive value for the diagnosis of BPD among infants of <29 weeks of gestation. TRIAL REGISTRATION ClinicalTrials.govNCT04756297.
Collapse
|
27
|
The Predictive Value of Lung Ultrasound Scores in Developing Bronchopulmonary Dysplasia: A Prospective Multicenter Diagnostic Accuracy Study. Chest 2021; 160:1006-1016. [PMID: 33689782 DOI: 10.1016/j.chest.2021.02.066] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 02/20/2021] [Accepted: 02/26/2021] [Indexed: 12/11/2022] Open
Abstract
BACKGROUND Different lung ultrasound (LUS) scanning protocols have been used, and the results in terms of diagnostic accuracy are heterogeneous. RESEARCH QUESTIONS What is the diagnostic accuracy of the LUS score to predict moderate to severe bronchopulmonary dysplasia (msBPD)? Does scanning of posterior lung fields improve the diagnostic accuracy? STUDY DESIGN AND METHODS This was a multicenter prospective, observational study in six centers. Two LUS aeration scores, one involving only anterolateral lung fields and the other adding the posterior fields were obtained at birth, on the third day of life (DOL), on the seventh DOL, on the 14th DOL, and on the 21st DOL. The diagnostic accuracy of both scores to predict msBPD was assessed at each time point. RESULTS Eight hundred thirty-two LUS examinations in 298 infants were included. Both LUS score using anterolateral and posterior fields and LUS score using only anterolateral fields showed a similar moderate diagnostic accuracy to predict msBPD on the third DOL (area under the receiver operating characteristic curve [AUC] 95% CI, 0.68-0.85 vs 0.68-0.85; P = .97), seventh DOL (AUC 95% CI, 0.74-0.85 vs 0.74-0.84; P = .26), and 21st DOL (AUC 95% CI, 0.72-0.86 vs 0.74-0.88; P = .17). The LUS score using anterolateral and posterior fields was slightly more accurate at 14th DOL (AUC 95% CI, 0.69-0.83 vs 0.66-0.80; P = .01). A cutoff of 8 points in the LUS score using only anterolateral fields on the seventh DOL provided a sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 70%, 79%, 3.3, and 0.38, respectively, to predict msBPD. Adding gestational age (GA) and sex improved the discriminative value without significant differences compared with a predictive model based on multiple clinical variables: AUC 95% CI, 0.77-0.88 vs 0.80-0.91 (P = .52). INTERPRETATION The LUS score is able to predict msBPD from the third DOL with a moderate diagnostic accuracy. Scanning posterior lung fields slightly improved diagnostic accuracy only at the 14th DOL. Adding GA and sex improves the diagnostic accuracy of the LUS scores. The LUS score is useful to stratify BPD risk early after birth.
Collapse
|
28
|
Szymański P, Kruczek P, Hożejowski R, Wais P. Modified lung ultrasound score predicts ventilation requirements in neonatal respiratory distress syndrome. BMC Pediatr 2021; 21:17. [PMID: 33407270 PMCID: PMC7785923 DOI: 10.1186/s12887-020-02485-z] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 12/20/2020] [Indexed: 01/23/2023] Open
Abstract
Background We propose a modified lung ultrasound (LUS) score in neonates with respiratory distress syndrome (RDS), which includes posterior instead of lateral lung fields, and a 5-grade rating scale instead of a 4-grade rating scale. The purpose of this study was to evaluate the reproducibility of the rating scale and its correlation with blood oxygenation and to assess the ability of early post-birth scans to predict the mode of respiratory support on day of life 3 (DOL 3). As a secondary objective, the weight of posterior scans in the overall LUS score was assessed. Methods We analyzed 619 serial lung scans performed in 70 preterm infants < 32 weeks gestation and birth weight < 1500 g. Assessments were performed within 24 h of birth (LUS0) and on days 2, 3, 5, 7, 10, 14, 21 and 28. LUS scores were correlated with oxygen saturation over fraction of inspired oxygen (S/F) and mode of respiratory support. Interrater agreement was determined with the intraclass correlation coefficient (ICC) and Cronbach’s alpha. Probabilities of the need for various respiratory support modes on DOL 3 were assessed with ordinal logistic regression. Least square (ls) means of the posterior and anterior pulmonary field scores were compared. Results The LUS score correlated significantly with S/F (Spearman rho = −0.635; p < 0.0001) and had excellent interrater agreement (ICC = 0.94, 95% CI 0.93–0.95; Cronbach’s alpha = 0.99). Significant predictors of ventilation requirements on DOL 3 were LUS0 (p < 0.016) and birth weight (BW) (p < 0.001). In the ROC analysis, LUS0 had high reliability in prognosing invasive ventilation on DOL 3 (AUC = 0.845 (95% DeLong CI: 0.738–0.951; p < 0.001)). Invasive ventilation was the most likely mode of respiratory support for LUS0 scores: ≥7 (in infants with BW 900 g), ≥ 10 (in infants with BW 1050 g) and ≥ 15 (in infants with BW 1280 g). Posterior fields exhibited significantly higher average scores than anterior fields. Respective ls means (confidence levels) were 4.0 (3.8–4.1) vs. 2.2 (2.0–2.4); p < 0.001. Conclusions Post-birth LUS predicts ventilation requirements on DOL 3. Scores of posterior pulmonary fields have a predominant weight in the overall LUS score.
Collapse
Affiliation(s)
- Piotr Szymański
- Department of Pediatrics, Jagiellonian University Medical College, Cracow, Poland.,Present address: Department of Neonatology, Ujastek Medical Center, ul. Ujastek 3, 31-752, Cracow, Poland
| | - Piotr Kruczek
- Department of Pediatrics, Jagiellonian University Medical College, Cracow, Poland. .,Present address: Department of Neonatology, Ujastek Medical Center, ul. Ujastek 3, 31-752, Cracow, Poland.
| | | | - Piotr Wais
- Department of Informatics, Carpathian State University in Krosno, Krosno, Poland
| |
Collapse
|
29
|
Elsayed YN, Hinton M, Graham R, Dakshinamurti S. Lung ultrasound predicts histological lung injury in a neonatal model of acute respiratory distress syndrome. Pediatr Pulmonol 2020; 55:2913-2923. [PMID: 32741109 PMCID: PMC7436735 DOI: 10.1002/ppul.24993] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 07/24/2020] [Indexed: 12/13/2022]
Abstract
RATIONALE Point-of-care ultrasound (POCUS) is used to evaluate pulmonary edema in adults with acute respiratory distress syndrome (ARDS). Its use has not been validated in neonatal models. OBJECTIVES We compared an in vivo lung ultrasound score against clinical and histological markers of acute lung injury, in a neonatal animal model, hypothesizing that POCUS would sensitively diagnose early acute lung injury in neonates and discern its severity. METHODS Fifteen anesthetized, ventilated 3-day-old neonatal piglets were divided into controls, moderate lung injury, or severe lung injury by graded treatment with oleic acid. Degree of lung injury was quantified at baseline, immediately after oleic acid administration, and 1 hour after the evolution of acute lung injury, by blood gases, ventilation parameters and calculated oxygenation deficit; hemodynamic indices by echocardiography, and lung ultrasound obtained in an 8-region grid of anterior and posterior zones, semi-quantitatively analyzed by a blinded observer. Lungs were inflation-fixed postmortem at last mean airway pressure, for histological assessment. RESULTS Acute lung injury manifested in oleic acid-treated groups as dose-dependent capillary leak causing intravascular depletion and cardiac failure, hypoxemia with increasing intrapulmonary shunt fraction, decreased lung compliance, and resistance. Ultrasound scores of anterior regions distinguished moderate from severe injury; scores in posterior regions reached maximum values immediately after lung injury. POCUS score correlated with calculated intrapulmonary shunt fraction (R2 = .65) and with histological injury score (R2 = .61), P < .01. CONCLUSION We conclude that POCUS may be valuable in neonates for early quantification of acute lung injury or ARDS; and that nondependent ultrasound regions clearly distinguish severity of pulmonary edema.
Collapse
Affiliation(s)
- Yasser N. Elsayed
- Department of Pediatrics, Section of NeonatologyUniversity of ManitobaWinnipegCanada
| | - Martha Hinton
- Biology of Breathing ThemeChildren's Hospital Research Institute of ManitobaWinnipegCanada
| | - Ruth Graham
- Department of AnesthesiaUniversity of ManitobaWinnipegCanada
| | - Shyamala Dakshinamurti
- Department of Pediatrics, Section of NeonatologyUniversity of ManitobaWinnipegCanada
- Biology of Breathing ThemeChildren's Hospital Research Institute of ManitobaWinnipegCanada
- Department of PhysiologyUniversity of ManitobaWinnipegCanada
| |
Collapse
|