1
|
Rhee SJ, Woo SH, Kim JS, Yun MS, Park C, Lee SM. Radiological and clinical outcomes after Attune primary total knee arthroplasty using Stemmable Tibia: A two-year follow-up prospective bi-center study. PLoS One 2024; 19:e0309015. [PMID: 39208149 PMCID: PMC11361569 DOI: 10.1371/journal.pone.0309015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Accepted: 08/03/2024] [Indexed: 09/04/2024] Open
Abstract
This prospective bi-center study aimed to analyze the outcomes of primary total knee arthroplasty using the Stemmable Tibia Attune system. A total of 100 patients who underwent primary total knee arthroplasty with Stemmable Tibia from January 2019 to December 2021 were enrolled in the study. Radiological outcomes (hip-knee-ankle axis and medial proximal tibial angle) were assessed preoperatively and postoperatively. Clinical outcomes (visual analog scale score, Hospital for Special Surgery score, Knee Society function score, Knee Society knee score, flexion contracture, further flexion, and range of motion) were analyzed preoperatively and at 6 weeks, 3 months, 6 months, 1 year, and 2 years postoperatively. Complications (periprosthetic joint infection and aseptic loosening) were examined. The hip-knee-ankle axis decreased (preoperative: 9.5° ± 6.3°, postoperative: 1.1° ± 2.7°), whereas the medial proximal tibial angle increased (preoperative: 84.6° ± 4.1°, postoperative: 89.8° ± 1.9°). The visual analog scale score, Hospital for Special Surgery score, Knee Society knee score, and Knee Society function score increased postoperatively. The Knee Society knee score indicated above good outcomes (100.0% and 99.0% at 1 and 2 years postoperatively, respectively). The Knee Society function score also showed above good results (98.0% and 93.0% at 1 and 2 years postoperatively, respectively). The range of motion significantly improved (p < 0.001): flexion contracture decreased from 9.10° ± 7.23° to 2.15° ± 2.87°, whereas further flexion increased from 136.05° ± 14.78° to 139.80° ± 10.02°. One patient developed periprosthetic joint infection; no early loosening was observed. In conclusion, Attune primary total knee arthroplasty with Stemmable Tibia not only is safe and effective but also leads to radiological and clinical improvements.
Collapse
Affiliation(s)
- Seung Joon Rhee
- Department of Orthopedic Surgery, Biomedical Research Institute, Pusan National University Hospital, Busan, Korea
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
| | - Seung Hun Woo
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Jung Shin Kim
- Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Mi Sook Yun
- Division of Biostatistics, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Chankue Park
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Department of Radiology, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Sang-Min Lee
- Pusan National University, Pusan National University School of Medicine, Yangsan, Republic of Korea
- Department of Orthopedic Surgery, Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| |
Collapse
|
2
|
Advances in Bone Joint Imaging-Metal Artifact Reduction. Diagnostics (Basel) 2022; 12:diagnostics12123079. [PMID: 36553086 PMCID: PMC9776622 DOI: 10.3390/diagnostics12123079] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/01/2022] [Accepted: 12/04/2022] [Indexed: 12/12/2022] Open
Abstract
Numerous types of metal implants have been introduced in orthopedic surgery and are used in everyday practice. To precisely evaluate the postoperative condition of arthroplasty or trauma surgery, periprosthetic infection, and the loosening of implants, it is important to reduce artifacts induced by metal implants. In this review, we focused on technical advances in metal artifact reduction using digital tomosynthesis, computed tomography, and magnetic resonance imaging. We discussed new developments in diagnostic imaging methods and the continuous introduction of novel technologies to reduce metal artifacts; however, these innovations have not yet completely removed metal artifacts. Different algorithms need to be selected depending on the size, shape, material and implanted body parts of an implant. Future advances in metal artifact reduction algorithms and techniques and the development of new sequences may enable further reductions in metal artifacts even on original images taken previously. Moreover, the combination of different imaging modalities may contribute to further reductions in metal artifacts. Clinicians must constantly update their knowledge and work closely with radiologists to select the best diagnostic imaging method for each metal implant.
Collapse
|