• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4628324)   Today's Articles (56)   Subscriber (49672)
For: Lawrie SR, Faircloth DC, Letchford AP, Gabor C, Pozimski JK. Plasma meniscus and extraction electrode studies of the ISIS H- ion source. Rev Sci Instrum 2010;81:02A707. [PMID: 20192377 DOI: 10.1063/1.3277139] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Number Cited by Other Article(s)
1
Design and simulation of NBI heating system using high dense helicon plasma source for Damavand Tokamak. FUSION ENGINEERING AND DESIGN 2018. [DOI: 10.1016/j.fusengdes.2018.09.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
2
Radwan SI, El-Khabeary H, Helal A. Improvement of extracted ion beam from cold cathode Penning ion source. Radiat Phys Chem Oxf Engl 1993 2018. [DOI: 10.1016/j.radphyschem.2017.09.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
3
Lawrie SR, Faircloth DC, Letchford AP, Whitehead MO, Wood T. Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H⁻ ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016;87:02B122. [PMID: 26932004 DOI: 10.1063/1.4934580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
4
Wang T, Yang Z, Dong P, long JD, He XZ, Wang X, Zhang KZ, Zhang LW. Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012;83:063302. [PMID: 22755617 DOI: 10.1063/1.4725534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
5
Gabor C, Faircloth DC, Lee DA, Lawrie SR, Letchford AP, Pozimski JK. Diagnostic experiments at a 3 MeV test stand at Rutherford Appleton Laboratory (United Kingdom). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010;81:02B718. [PMID: 20192458 DOI: 10.1063/1.3290858] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
6
Faircloth DC, Lawrie S, Letchford AP, Gabor C, Wise P, Whitehead M, Wood T, Westall M, Findlay D, Perkins M, Savage PJ, Lee DA, Pozimski JK. The front end test stand high performance H- ion source at Rutherford Appleton Laboratory. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2010;81:02A721. [PMID: 20192390 DOI: 10.1063/1.3271169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA