1
|
Fang C, Dai B, Xu Q, Zhuo R, Wang Q, Wang X, Zhang D. Hydrodynamically reconfigurable optofluidic microlens with continuous shape tuning from biconvex to biconcave. OPTICS EXPRESS 2017; 25:888-897. [PMID: 28157977 DOI: 10.1364/oe.25.000888] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This paper presents an in-plane hydrodynamically reconfigurable optofluidic microlens, which is formed by the laminar flow of two streams of a low-refractive-index fluid and two streams of a high-refractive-index fluid in the two microchannels connecting to an expansion chamber where the microlens finally forms. In the expansion chamber, the stream of high-refractive-index fluid, acting as core, is sandwiched by the two streams of low-refractive-index fluid, acting as cladding. The interfaces between the streams can be flexibly manipulated by controlling the flow rate ratio between the two fluids in real time. Thus, the biconvex and biconcave microlens with different curvatures can be formed. By adjusting the microlens, the light beam can be continuously manipulated from focusing to collimation and then to divergence. In the experiment, a wide focus tuning range from 2.75 (focusing) to -1.21 mm (diverging) via collimation is achieved.
Collapse
|
2
|
Shi Y, Zhu XQ, Liang L, Yang Y. Tunable focusing properties using optofluidic Fresnel zone plates. LAB ON A CHIP 2016; 16:4554-4559. [PMID: 27785508 DOI: 10.1039/c6lc01115b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A Fresnel zone plate (FZP) is a unique diffractive optical device and widely used in integrated optical systems such as interferometers and antennas. A traditional FZP utilizes solid materials and cannot be modulated in real time for desired focusing properties. This paper reports a tunable optofluidic FZP based on a solid-liquid hybrid structure. This FZP consists of two parts including a fast microfluidic mixer, which can adjust the refractive index of liquids from 1.332 to 1.432, and subsequently an optical FZP with a solid-liquid combination. Simulations and experiments successfully showed the real-time tunability of the focusing properties such as peak intensity, focal spot sizes and focal lengths. The focal spot size can be modulated from 16 μm to 80 μm at λ0 = 532 nm in experiments with focal length changes of approximately 700 μm. Moreover, it can be easily switched between focusing, defocusing and collimation. The dispersion with different wavelengths was also investigated, showing that these types of focusing properties are quite different from a traditional optofluidic lens by refraction or reflection. It is foreseeable that such a hybrid FZP may find wider applications in lab-on-a-chip systems and optical devices.
Collapse
Affiliation(s)
- Y Shi
- School of Physics & Technology, Wuhan University, Wuhan 430072, China.
| | - X Q Zhu
- School of Physics & Technology, Wuhan University, Wuhan 430072, China.
| | - L Liang
- School of Physics & Technology, Wuhan University, Wuhan 430072, China.
| | - Y Yang
- School of Physics & Technology, Wuhan University, Wuhan 430072, China.
| |
Collapse
|
3
|
Zhao HT, Yang Y, Chin LK, Chen HF, Zhu WM, Zhang JB, Yap PH, Liedberg B, Wang K, Wang G, Ser W, Liu AQ. Optofluidic lens with low spherical and low field curvature aberrations. LAB ON A CHIP 2016; 16:1617-24. [PMID: 27050492 DOI: 10.1039/c6lc00295a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This paper reports an optofluidic lens with low spherical and low field curvature aberrations through the desired refractive index profile by precisely controlling the mixing between ethylene glycol and deionized water in an optofluidic chip. The experimental results demonstrate that the spherical aberration is reduced to 19.5 μm and the full width at half maximum of the focal point is 7.8 μm with a wide divergence angle of 35 degrees. In addition, the optofluidic lens can focus light at different off-axis positions on the focal plane with Δx' < 6.8 μm and at opposite transverse positions with |Δy - Δy'| < 5.7 μm. This is the first demonstration of a special optofluidic lens that significantly reduces both the spherical and field curvature aberrations, which enhances the focusing power and facilitates multiple light source illumination using a single lens. It is anticipated to have high potential for applications such as on-chip light manipulation, sample illumination and multiplexed detection.
Collapse
Affiliation(s)
- H T Zhao
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - Y Yang
- School of Physics and Technology, Wuhan University, Wuhan 430072, China
| | - L K Chin
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - H F Chen
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - W M Zhu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - J B Zhang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - P H Yap
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232
| | - B Liedberg
- Interdisciplinary Graduate School, Nanyang Technological University, Singapore 639798
| | - K Wang
- Institute of Biological Chemistry, Academia Sinica, Taipei 115, Taiwan and College of Medical Science and Technology, Taipei Medical University, Taipei 110, Taiwan
| | - G Wang
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - W Ser
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| | - A Q Liu
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798.
| |
Collapse
|
4
|
Xiao G, Zhu Q, Shen Y, Li K, Liu M, Zhuang Q, Jin C. A tunable submicro-optofluidic polymer filter based on guided-mode resonance. NANOSCALE 2015; 7:3429-3434. [PMID: 25630880 DOI: 10.1039/c4nr07233b] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Optical filters with reconfigurable spectral properties are highly desirable in a wide range of applications. We propose and experimentally demonstrate a tunable submicro-optofluidic polymer guided-mode resonance (PGMR) filter. The device is composed of a periodic grating sandwiched between a high index waveguide layer and a low index capping layer, which integrates submicro-fluidic channel arrays and a PGMR filter elegantly. A finite difference time domain (FDTD) method is employed to understand the spectral properties and determine appropriate device parameters. We fabricated the polymer guided-mode resonance filter with a method combining two-beam interference lithography, floating nanofilm transfer and thermal bonding techniques. Experimental results show that our tunable submicro-optofluidic PGMR filters can provide a broad spectral tuning range (13.181 nm), a narrow bandwidth (<2.504 nm), and a high reflection efficiency (>85%) in the visible region. Such submicro-optofluidic PGMR filters are highly compatible with existing nano/microfluidic technologies and would be valuable for the integrated flexible optical system.
Collapse
Affiliation(s)
- Guohui Xiao
- State Key Laboratory of Optoelectronic Materials and Technologies, School of Physics and Engineering, Sun Yat-Sen University, Guangzhou, 510275, China.
| | | | | | | | | | | | | |
Collapse
|
5
|
Cuennet JG, Vasdekis AE, Psaltis D. Optofluidic-tunable color filters and spectroscopy based on liquid-crystal microflows. LAB ON A CHIP 2013; 13:2721-2726. [PMID: 23752198 DOI: 10.1039/c3lc50501d] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The integration of color filters with microfluidics has attracted substantial attention in recent years, for on-chip absorption, fluorescence, or Raman analysis. We describe such tunable filters based on the micro-flow of liquid crystals. The filter operation is based on the wavelength-dependent liquid crystal birefringence that can be tuned by modifying the flow velocity field in the microchannel. The latter is possible both temporally and spatially by varying the inlet pressure and the channel geometry, respectively. We explored the use of these optofluidic filters for on-chip absorption spectroscopy in poly(dimethylsiloxane) microfluidic systems; by integrating the distance-dependent color filter with a dye-filled micro-channel, the absorption spectrum of a dye could be measured. Liquid crystal microflows substantially simplify the optofluidic integration, actuation and tuning of color filters for lab-on-a-chip spectroscopic applications.
Collapse
Affiliation(s)
- J G Cuennet
- Optics Laboratory, School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland
| | | | | |
Collapse
|
6
|
Bhuvana T, Kim B, Yang X, Shin H, Kim E. Reversible Full-Color Generation with Patterned Yellow Electrochromic Polymers. Angew Chem Int Ed Engl 2012; 52:1180-4. [DOI: 10.1002/anie.201205206] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2012] [Revised: 08/21/2012] [Indexed: 11/05/2022]
|
7
|
Bhuvana T, Kim B, Yang X, Shin H, Kim E. Reversible Full-Color Generation with Patterned Yellow Electrochromic Polymers. Angew Chem Int Ed Engl 2012. [DOI: 10.1002/ange.201205206] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
8
|
Seow YC, Lim SP, Lee HP. Optofluidic variable-focus lenses for light manipulation. LAB ON A CHIP 2012; 12:3810-3815. [PMID: 22885654 DOI: 10.1039/c2lc40415j] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This paper presents a planar optofluidic lens for light manipulation utilizing a combination of optofluidic biconvex lens with micromixer. Three light manipulation techniques including tunable optical diverging, collimating and focusing are realized by altering the refractive index of the optofluidic variable-focus lenses formed by solid polydimethylsiloxane (PDMS) walls and tunable liquid lens body. The optical power from the laser input can be increased or decreased with the tuning of the variable-focus lenses' refractive indexes. The optical power adjustment capabilities are demonstrated and characterized. The combinations of benefits of all lens' optical manipulation capabilities, greater mechanical stability, significant increase of optofluidic device's life time and seamless integration with other lab-on-a-chip functionalities provide a promising and versatile optofluidic compartment to integrate with lab-on-a-chip excitation and sensing applications. Optofluidic lens-including system for tunable fluorescence sensing is demonstrated showing 186% increase in detected fluorescence intensity.
Collapse
Affiliation(s)
- Y C Seow
- Applied Mechanics Laboratory, Department of Mechanical Engineering, National University of Singapore, 1 Engineering Drive 2, Singapore 117576.
| | | | | |
Collapse
|
9
|
De Sio L, Romito M, Giocondo M, Vasdekis AE, De Luca A, Umeton C. Electro-switchable polydimethylsiloxane-based optofluidics. LAB ON A CHIP 2012; 12:3760-3765. [PMID: 22859213 DOI: 10.1039/c2lc40668c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We report on the fabrication and characterization of a new generation of electro-switchable optofluidic devices based on flexible substrates, combined with the extraordinary properties of reconfigurable soft-materials. A conductive polydimethylsiloxane microstructure has been first sputtered with an Indium Tin Oxide (ITO) layer and then functionalized with an amorphous film of SiO(x). Then, the "layer" by "layer" microstructure has been infiltrated with an anisotropic and reconfigurable fluid (Nematic Liquid Crystal, NLC). The sample has been characterized in terms of morphological, optical and electro-optical properties: the soft-conductive microstructure exhibits a uniform and regular morphology, even after testing with mechanical stretching and deformations. Combination of the conductive ITO with the functionalization film (which has been employed for inducing in-plane alignment of NLC molecules) enables us to carry out a series of optical and electro-optical experiments; these confirm excellent properties in terms of a reconfigurable device and a diffractive element as well.
Collapse
Affiliation(s)
- Luciano De Sio
- Department of Physics-University of Calabria, Centre of Excellence for the Study of Innovative Functional Materials and CNR-IPCF UOS Cosenza, 87036 Arcavacata di Rende, Italy.
| | | | | | | | | | | |
Collapse
|
10
|
Bhuvana T, Kim B, Yang X, Shin H, Kim E. Electroactive subwavelength gratings (ESWGs) from conjugated polymers for color and intensity modulation. NANOSCALE 2012; 4:3679-3686. [PMID: 22622524 DOI: 10.1039/c2nr30611e] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Subwavelength gratings with electroactive polymers such as poly(3-hexylthiophene) (P3HT) and poly(3,4-propylenedioxythiophene-phenylene) (P(ProDOT-Ph)) controlled the color intensity for various visible colors of diffracted light in a single device. Under the illumination of a white light, at a fixed angle of incidence, the color intensity of the diffracted light was reversibly switched from the maximum value down to 15% (85% decrease) by applying -2 to 2 V due to electrochemical (EC) reaction. All spectral colors including red, green, and blue were generated by changing the angle of incidence, and the intensity of each color was modulated electrochemically at a single EC device. With electroactive subwavelength gratings (ESWGs) of P3HT, the maximum modulation of the color intensity was observed in the red-yellow quadrant in the CIE color plot, whereas for the ESWGs of P(ProDOT-Ph), the maximum modulation of the color intensity was observed in the yellow-green and green-blue quadrants. Both ESWGs showed a memory effect, keeping their color and intensity even after power was turned off for longer than 40 hours.
Collapse
Affiliation(s)
- Thiruvelu Bhuvana
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 120-749, Republic of Korea
| | | | | | | | | |
Collapse
|
11
|
Song W, Psaltis D. Optofluidic membrane interferometer: An imaging method for measuring microfluidic pressure and flow rate simultaneously on a chip. BIOMICROFLUIDICS 2011; 5:44110-4411011. [PMID: 22662062 PMCID: PMC3364809 DOI: 10.1063/1.3664693] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2011] [Accepted: 11/02/2011] [Indexed: 05/23/2023]
Abstract
We present a novel image-based method to measure the on-chip microfluidic pressure and flow rate simultaneously by using the integrated optofluidic membrane interferometers (OMIs). The device was constructed with two layers of structured polydimethylsiloxane (PDMS) on a glass substrate by multilayer soft lithography. The OMI consists of a flexible air-gap optical cavity which upon illumination by monochromatic light generates interference patterns that depends on the pressure. These interference patterns were captured with a microscope and analyzed by computer based on a pattern recognition algorithm. Compared with the previous techniques for pressure sensing, this method offers several advantages including low cost, simple fabrication, large dynamic range, and high sensitivity. For pressure sensing, we demonstrate a dynamic range of 0-10 psi with an accuracy of ±2% of full scale. Since multiple OMIs can be integrated into a single chip for detecting pressures at multiple locations simultaneously, we also demonstrated a microfluidic flow sensing by measuring the differential pressure along a channel. Thanks to the simple fabrication that is compatible with normal microfluidics, such OMIs can be easily integrated into other microfluidic systems for in situ fluid monitoring.
Collapse
Affiliation(s)
- Wuzhou Song
- School of Engineering, Swiss Federal Institute of Technology Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | | |
Collapse
|
12
|
Liu AQ. Preface to special topic: optofluidics. BIOMICROFLUIDICS 2010; 4:42901. [PMID: 21267433 PMCID: PMC3026023 DOI: 10.1063/1.3533774] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2010] [Accepted: 12/14/2010] [Indexed: 05/05/2023]
Abstract
This Special Topic section of Biomicrofluidics is on optofluidics or micro-optofluidic systems (MOFS), a burgeoning technology that aims to manipulate light and fluid at microscale and exploits their interaction to create highly versatile devices and integrated systems. This special issue puts together various contributed articles focusing on optofluidics or MOFS, which help inspire new research ideas and innovation in the microfluidics and nanofluidics community.
Collapse
Affiliation(s)
- Ai-Qun Liu
- School of Electrical & Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| |
Collapse
|