Comparison of
UV-induced AOPs (
UV/Cl2, UV/NH2Cl, UV/ClO2 and
UV/H2O2 ) in the degradation of iopamidol: Kinetics, energy requirements and DBPs-related toxicity in sequential disinfection processes.
CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2020;
398:125570. [PMID:
32508521 PMCID:
PMC7260538 DOI:
10.1016/j.cej.2020.125570]
[Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 05/16/2020] [Accepted: 05/18/2020] [Indexed: 05/18/2023]
Abstract
The UV-induced advanced oxidation processes (AOPs, including UV/Cl2, UV/NH2Cl, UV/ClO2 and UV/H2O2 ) degradation kinetics and energy requirements of iopamidol as well as DBPs-related toxicity in sequential disinfection were compared in this study. The photodegradation of iopamidol in these processes can be well described by pseudo-first-order model and the removal efficiency ranked in descending order of UV/Cl2 > UV/H2O2 > UV/NH2Cl > UV/ClO2 > UV. The synergistic effects could be attributed to diverse radical species generated in each system. Influencing factors of oxidant dosage, UV intensity, solution pH and water matrixes (Cl- , NH4 + and nature organic matter) were evaluated in detail. Higher oxidant dosages and greater UV intensities led to bigger pseudo-first-order rate constants (Kobs) in these processes, but the pH behaviors exhibited quite differently. The presence of Cl- , NH4 + and nature organic matter posed different effects on the degradation rate. The parameter of electrical energy per order (EE/O) was adopted to evaluate the energy requirements of the tested systems and it followed the trend of UV/ClO2 > UV > UV/NH2Cl > UV/H2O2 > UV/Cl2 . Pretreatment of iopamidol by UV/Cl2 and UV/NH2Cl clearly enhanced the production of classical disinfection by-products (DBPs) and iodo-trihalomethanes (I-THMs) during subsequent oxidation while UV/ClO2 and UV/H2O2 exhibited almost elimination effect. From the perspective of weighted water toxicity, the risk ranking was UV/NH2Cl > UV/Cl2 > UV > UV/H2O2 > UV/ClO2 . Among the discussed UV-driven AOPs, UV/Cl2 was proved to be the most cost-effective one for iopamidol removal while UV/ClO2 displayed overwhelming advantages in regulating the water toxicity associated with DBPs, especially I-THMs. The present results could provide some insights into the application of UV-activated AOPs technologies in tradeoffs between cost-effectiveness assessment and DBPs-related toxicity control of the disinfected waters containing iopamidol.
Collapse