1
|
Moroco JA, Jacome ASV, Beltran PMJ, Reiter A, Mundorff C, Guttman M, Morrow J, Coales S, Mayne L, Hamuro Y, Carr SA, Papanastasiou M. High-Throughput Determination of Exchange Rates of Unmodified and PTM-Containing Peptides Using HX-MS. Mol Cell Proteomics 2025; 24:100904. [PMID: 39788320 PMCID: PMC11875167 DOI: 10.1016/j.mcpro.2025.100904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 12/12/2024] [Accepted: 01/03/2025] [Indexed: 01/12/2025] Open
Abstract
Despite the widespread use of MS for hydrogen/deuterium exchange measurements, no systematic, large-scale study has been conducted to compare the observed exchange rates in protein-derived, unstructured peptides measured by MS to the predicted exchange rates calculated from NMR-derived values and how neighboring residues and post-translational modifications influence those exchange rates. In this study, we sought to test the accuracy of predicted values by performing hydrogen exchange measurements on whole cell digests to generate an unbiased dataset of 563 unique peptides derived from naturally occurring protein sequences. A remarkable 97% of observed exchange rates of peptides are within two-fold of predicted values. Using fully deuterated controls, we found that for approximately 50% of the peptides, the amino acid sequence and, consequently, the intrinsic exchange rate, are the primary contributors to back exchange. A meta-analysis of the remaining physicochemical properties of peptides revealed multiple features that contribute either positively or negatively to back exchange discrepancies. Employing our workflow for comparable measurements on synthetic peptide mixtures containing post-translational modifications, and their unmodified counterparts, we show that lysine acetylation has a strong effect on the observed exchange rate, whereas serine/threonine phosphorylation does not. Our automated workflow enables high-throughput determination of exchange rates in complex biological peptide mixtures with diverse properties.
Collapse
Affiliation(s)
- Jamie A Moroco
- Broad Institute of MIT & Harvard, Cambridge, Massachusetts, USA
| | | | | | - Andrew Reiter
- Broad Institute of MIT & Harvard, Cambridge, Massachusetts, USA
| | - Charlie Mundorff
- Department of Medicinal Chemistry, University of Washington, Seattle, Washington, USA
| | - Miklos Guttman
- Department of Medicinal Chemistry, University of Washington, Seattle, Washington, USA
| | - Jeff Morrow
- Trajan Scientific and Medical, Morrisville, North Carolina, USA
| | - Stephen Coales
- Trajan Scientific and Medical, Morrisville, North Carolina, USA
| | - Leland Mayne
- Department of Biochemistry and Biophysics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Massachusetts, USA
| | - Yoshitomo Hamuro
- Janssen Research and Development, Spring House, Pennsylvania, USA
| | - Steven A Carr
- Broad Institute of MIT & Harvard, Cambridge, Massachusetts, USA.
| | | |
Collapse
|
2
|
Using hydrogen-deuterium exchange mass spectrometry to characterize Mtr4 interactions with RNA. Methods Enzymol 2022; 673:475-516. [PMID: 35965017 DOI: 10.1016/bs.mie.2022.04.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Hydrogen deuterium exchange coupled to mass spectrometry (HDX-MS) is a valuable technique to investigate the dynamics of protein systems. The approach compares the deuterium uptake of protein backbone amides under multiple conditions to characterize protein conformation and interaction. HDX-MS is versatile and can be applied to diverse ligands, however, challenges remain when it comes to exploring complexes containing nucleic acids. In this chapter, we present procedures for the optimization and application of HDX-MS to studying RNA-binding proteins and use the RNA helicase Mtr4 as a demonstrative example. We highlight considerations in designing on-exchange, bottom-up, comparative studies on proteins with RNA. Our protocol details preliminary testing and optimization of experimental parameters. Difficulties arising from the inclusion of RNA, such as signal repression and sample carryover, are addressed. We discuss how chromatography parameters can be adjusted depending on the issues presented by the RNA, emphasizing reproducible peptide recovery in the absence and presence of RNA. Methods for visualization of HDX data integrated with statistical analysis are also reviewed with examples. These protocols can be applied to future studies of various RNA-protein complexes.
Collapse
|
3
|
James EI, Murphree TA, Vorauer C, Engen JR, Guttman M. Advances in Hydrogen/Deuterium Exchange Mass Spectrometry and the Pursuit of Challenging Biological Systems. Chem Rev 2021; 122:7562-7623. [PMID: 34493042 PMCID: PMC9053315 DOI: 10.1021/acs.chemrev.1c00279] [Citation(s) in RCA: 154] [Impact Index Per Article: 38.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
![]()
Solution-phase hydrogen/deuterium
exchange (HDX) coupled to mass
spectrometry (MS) is a widespread tool for structural analysis across
academia and the biopharmaceutical industry. By monitoring the exchangeability
of backbone amide protons, HDX-MS can reveal information about higher-order
structure and dynamics throughout a protein, can track protein folding
pathways, map interaction sites, and assess conformational states
of protein samples. The combination of the versatility of the hydrogen/deuterium
exchange reaction with the sensitivity of mass spectrometry has enabled
the study of extremely challenging protein systems, some of which
cannot be suitably studied using other techniques. Improvements over
the past three decades have continually increased throughput, robustness,
and expanded the limits of what is feasible for HDX-MS investigations.
To provide an overview for researchers seeking to utilize and derive
the most from HDX-MS for protein structural analysis, we summarize
the fundamental principles, basic methodology, strengths and weaknesses,
and the established applications of HDX-MS while highlighting new
developments and applications.
Collapse
Affiliation(s)
- Ellie I James
- Department of Medicinal Chemistry, University of Washington, Seattle, Washington 98195, United States
| | - Taylor A Murphree
- Department of Medicinal Chemistry, University of Washington, Seattle, Washington 98195, United States
| | - Clint Vorauer
- Department of Medicinal Chemistry, University of Washington, Seattle, Washington 98195, United States
| | - John R Engen
- Department of Chemistry & Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States
| | - Miklos Guttman
- Department of Medicinal Chemistry, University of Washington, Seattle, Washington 98195, United States
| |
Collapse
|
4
|
Engen JR, Botzanowski T, Peterle D, Georgescauld F, Wales TE. Developments in Hydrogen/Deuterium Exchange Mass Spectrometry. Anal Chem 2020; 93:567-582. [DOI: 10.1021/acs.analchem.0c04281] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- John R. Engen
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States
| | - Thomas Botzanowski
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States
| | - Daniele Peterle
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States
| | - Florian Georgescauld
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States
| | - Thomas E. Wales
- Department of Chemistry and Chemical Biology, Northeastern University, Boston, Massachusetts 02115, United States
| |
Collapse
|
5
|
Mullahoo J, Zhang T, Clauser K, Carr SA, Jaffe JD, Papanastasiou M. Dual protease type XIII/pepsin digestion offers superior resolution and overlap for the analysis of histone tails by HX-MS. Methods 2020; 184:135-140. [PMID: 32004545 DOI: 10.1016/j.ymeth.2020.01.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 01/22/2020] [Accepted: 01/26/2020] [Indexed: 01/26/2023] Open
Abstract
The N-terminal regions of histone proteins (tails) are dynamic elements that protrude from the nucleosome and are involved in many aspects of chromatin organization. Their epigenetic role is well-established, and post-translational modifications (PTMs) present on these regions contribute to transcriptional regulation. While hydrogen/deuterium exchange mass spectrometry (HX-MS) is well-suited for the analysis of dynamic structures, it has seldom been employed to analyze histones due to the poor N-terminal coverage obtained using pepsin. Here, we test the applicability of a dual protease type XIII/pepsin digestion column to this class of proteins. We optimize online digestion conditions using the H4 monomer, and extend the method to the analysis of histones in monomeric states and nucleosome core particles (NCPs). We show that the dual protease column generates many short and overlapping N-terminal peptides. We evaluate our method by performing hydrogen exchange experiments of NCPs for different time points and present full coverage of the tails at excellent resolution. We further employ electron transfer dissociation and showcase an unprecedented degree of overlap across multiple peptides that is several fold higher than previously reported methods. The method we report here may be readily applied to the HX-MS investigation of histone dynamics and to the footprints of histone binding proteins on nucleosomes.
Collapse
Affiliation(s)
- James Mullahoo
- The Broad Institute of MIT and Harvard, Cambridge, MA, United States
| | - Terry Zhang
- Thermo Scientific, San Jose, CA, United States
| | - Karl Clauser
- The Broad Institute of MIT and Harvard, Cambridge, MA, United States
| | - Steven A Carr
- The Broad Institute of MIT and Harvard, Cambridge, MA, United States
| | - Jacob D Jaffe
- The Broad Institute of MIT and Harvard, Cambridge, MA, United States
| | | |
Collapse
|