1
|
Breenfeldt Andersen A, Bonne TC, Nordsborg NB, Holm-Sørensen H, Bejder J. Duplicate measures of hemoglobin mass within an hour: feasibility, reliability, and comparison of three devices in supine position. Scand J Clin Lab Invest 2024; 84:1-10. [PMID: 38265850 DOI: 10.1080/00365513.2024.2303711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 12/17/2023] [Indexed: 01/25/2024]
Abstract
Duplicate measure of hemoglobin mass by carbon monoxide (CO)-rebreathing is a logistical challenge as recommendations prompt several hours between measures to minimize CO-accumulation. This study investigated the feasibility and reliability of performing duplicate CO-rebreathing procedures immediately following one another. Additionally, it was evaluated whether the obtained hemoglobin mass from three different CO-rebreathing devices is comparable. Fifty-five healthy participants (22 males, 23 females) performed 222 duplicate CO-rebreathing procedures in total. Additionally, in a randomized cross-over design 10 participants completed three experimental trials, each including three CO-rebreathing procedures, with the first and second separated by 24 h and the second and third separated by 5-10 min. Each trial was separated by >48 h and conducted using either a glass-spirometer, a semi-automated electromechanical device, or a standard three-way plastic valve designed for pulmonary measurements. Hemoglobin mass was 3 ± 22 g lower (p < 0.05) at the second measure when performed immediately after the first with a typical error of 1.1%. Carboxyhemoglobin levels reached 10.9 ± 1.3%. In the randomized trial, hemoglobin mass was similar between the glass-spirometer and three-way valve, but ∼6% (∼50 g) higher for the semi-automated device. Notably, differences in hemoglobin mass were up to ∼13% (∼100 g) when device-specific recommendations for correction of CO loss to myoglobin and exhalation was followed. In conclusion, it is feasible and reliable to perform two immediate CO-rebreathing procedures. Hemoglobin mass is comparable between the glass-spirometer and the three-way plastic valve, but higher for the semi-automated device. The differences are amplified if the device-specific recommendations of CO-loss corrections are followed.
Collapse
Affiliation(s)
| | - Thomas Christian Bonne
- Department of Nutrition, Exercise and Sports (NEXS), University of Copenhagen, Copenhagen, Denmark
| | | | - Henrik Holm-Sørensen
- Department of Anaesthesiology, Centre for Cancer and Organ Diseases, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Jacob Bejder
- Department of Nutrition, Exercise and Sports (NEXS), University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
2
|
Oberholzer L, Montero D, Robach P, Siebenmann C, Ryrsøe CK, Bonne TC, Breenfeldt Andersen A, Bejder J, Karlsen T, Edvardsen E, Rønnestad BR, Hamarsland H, Cepeda-Lopez AC, Rittweger J, Treff G, Ahlgrim C, Almquist NW, Hallén J, Lundby C. Determinants and reference values for blood volume and total hemoglobin mass in women and men. Am J Hematol 2024; 99:88-98. [PMID: 38032792 DOI: 10.1002/ajh.27162] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Revised: 10/04/2023] [Accepted: 10/12/2023] [Indexed: 12/02/2023]
Abstract
Blood volume (BV) is an important clinical parameter and is usually reported per kg of body mass (BM). When fat mass is elevated, this underestimates BV/BM. One aim was to study if differences in BV/BM related to sex, age, and fitness would decrease if normalized to lean body mass (LBM). The analysis included 263 women and 319 men (age: 10-93 years, body mass index: 14-41 kg/m2 ) and 107 athletes who underwent assessment of BV and hemoglobin mass (Hbmass ), body composition, and cardiorespiratory fitness. BV/BM was 25% lower (70.3 ± 11.3 and 80.3 ± 10.8 mL/kgBM ) in women than men, respectively, whereas BV/LBM was 6% higher in women (110.9 ± 12.5 and 105.3 ± 11.2 mL/kgLBM ). Hbmass /BM was 34% lower (8.9 ± 1.4 and 11.5 ± 11.2 g/kgBM ) in women than in men, respectively, but only 6% lower (14.0 ± 1.5 and 14.9 ± 1.5 g/kgLBM )/LBM. Age did not affect BV. Athlete's BV/BM was 17.2% higher than non-athletes, but decreased to only 2.5% when normalized to LBM. Of the variables analyzed, LBM was the strongest predictor for BV (R2 = .72, p < .001) and Hbmass (R2 = .81, p < .001). These data may only be valid for BV/Hbmass when assessed by CO re-breathing. Hbmass /LBM could be considered a valuable clinical matrix in medical care aiming to normalize blood homeostasis.
Collapse
Affiliation(s)
- Laura Oberholzer
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - David Montero
- Department of Medicine, School of Clinical Medicine/Public Health, The University of Hongkong, Hongkong, China
| | - Paul Robach
- Ecole Nationale des Sports de Montagne, site de l'Ecole Nationale de Ski et d'Alpinisme, Chamonix, France
| | | | - Camilla Koch Ryrsøe
- Department of Infectious Diseases and Pulmonary Medicine, Nordsjaellands University Hospital, Hillerød, Denmark
| | - Thomas C Bonne
- Department of Nutrition, Exercise and Sports (NEXS), University of Copenhagen, Copenhagen, Denmark
| | | | - Jacob Bejder
- Department of Nutrition, Exercise and Sports (NEXS), University of Copenhagen, Copenhagen, Denmark
| | - Trine Karlsen
- Faculty of Nursing and Health Sciences, Nord University, Bodø, Norway
- Cardiac Exercise Research Group, Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science of Technology, Trondheim, Norway
| | - Elisabeth Edvardsen
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Bent R Rønnestad
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Håvard Hamarsland
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| | - Ana C Cepeda-Lopez
- Health Sciences Division, University of Monterrey (UDEM), Monterrey, Mexico
| | - Jörn Rittweger
- German Aerospace Center (DLR), Institute of Aerospace Medicine, Cologne, Germany
- Department of Pediatrics and Adolescent Medicine, University Hospital Cologne, Cologne, Germany
| | - Gunnar Treff
- Division of Sports and Rehabilitation Medicine, Ulm University Hospital, Ulm, Germany
| | - Christoph Ahlgrim
- University Heart Center Freiburg, Medical Center-University of Freiburg, Bad Krozingen, Germany
| | - Nicki Winfield Almquist
- Department of Nutrition, Exercise and Sports (NEXS), University of Copenhagen, Copenhagen, Denmark
| | - Jostein Hallén
- Department of Physical Performance, Norwegian School of Sport Sciences, Oslo, Norway
| | - Carsten Lundby
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| |
Collapse
|
3
|
Lundby C. Comment by Schmidt and Byrnes based on erroneous assumptions. Scand J Clin Lab Invest 2023; 83:356-357. [PMID: 37452604 DOI: 10.1080/00365513.2023.2233078] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 06/29/2023] [Accepted: 07/02/2023] [Indexed: 07/18/2023]
Affiliation(s)
- Carsten Lundby
- Section for Health and Exercise Physiology, Inland Norway University of Applied Sciences, Lillehammer, Norway
| |
Collapse
|
4
|
Schmidt WFJ, Hoffmeister T, Wachsmuth NB, Byrnes WC. The effect of posture and exercise on blood CO kinetics during the optimized carbon monoxide rebreathing procedure. Scand J Clin Lab Invest 2023:1-8. [PMID: 37154842 DOI: 10.1080/00365513.2023.2204402] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
An indispensable precondition for the determination of hemoglobin mass (Hbmass) and blood volume by CO rebreathing is complete mixing of CO in the blood. The aim of this study was to demonstrate the kinetics of CO in capillary and venous blood in different body positions and during moderate exercise. Six young subjects (4 male, 2 female) performed three 2-min CO rebreathing tests in seated (SEA) & supine (SUP) positions as well as during moderate exercise (EX) on a bicycle ergometer. Before, during, and until 15 min after CO rebreathing cubital venous and capillary blood samples were collected simultaneously and COHb% was determined. COHb% kinetics were significantly slower in SEA than in SUP or EX. Identical COHb% in capillary and venous blood were reached in SEA after 5.0 ± 2.3 min, in SUP after 3.2 ± 1.3 min and in EX after 1.9 ± 1.2 min (EX vs. SEA p < .01, SUP vs. SEA p < .05). After 7th min, Hbmass did not differ between the resting positions (capillary: SEA 766 ± 217 g, SUP 761 ± 227 g; venous: SEA 759 ± 224 g, SUP 744 ± 207 g). Under exercise, however, a higher Hbmass (p < .05) was determined (capillary: 823 ± 221 g, venous: 804 ± 226 g). In blood, the CO mixing time in the supine position is significantly shorter than in the seated position. By the 6th minute complete mixing is achieved in either position giving similar Hbmass determinations. CO-rebreathing under exercise conditions, however, leads to ∼7% higher Hbmass values.
Collapse
Affiliation(s)
- Walter F J Schmidt
- Department of Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany
- Division of Exercise Physiology & Metabolism, University of Bayreuth, Bayreuth, Germany
| | - Torben Hoffmeister
- Department of Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - Nadine B Wachsmuth
- Division of Exercise Physiology & Metabolism, University of Bayreuth, Bayreuth, Germany
| | - William C Byrnes
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| |
Collapse
|
5
|
Schmidt WFJ, Byrnes WC. Comments on comparison of the automatised and the optimised carbon monoxide rebreathing methods. Scand J Clin Lab Invest 2023:1-2. [PMID: 37149794 DOI: 10.1080/00365513.2023.2204403] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Affiliation(s)
- Walter F J Schmidt
- Departemet of Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - William C Byrnes
- Department of Integrative Physiology, University of Colorado, Boulder, CO, USA
| |
Collapse
|
6
|
Royal JT, Fisher JT, Mlinar T, Mekjavic IB, McDonnell AC. Validity and reliability of capillary vs. Venous blood for the assessment of haemoglobin mass and intravascular volumes. Front Physiol 2022; 13:1021588. [PMID: 36505074 PMCID: PMC9730879 DOI: 10.3389/fphys.2022.1021588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 11/14/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives: Haemoglobin mass (Hbmass) assessment with the carbon monoxide rebreathing method is a more accurate estimate than other measures of oxygen-carrying capacity. Blood may be collected by several means and differences in the measured variables may exist as a result. The present study assessed the validity and reliability of calculated Hbmass and intravascular volumes obtained from capillary blood (CAP) when compared to venous blood (VEN) draws. Methods: Twenty-two adults performed a carbon monoxide rebreathing procedure with paired VEN and CAP draws at baseline, pre-rebreathing and post-rebreathing (POST). Thirteen of these participants performed this protocol on two occasions to assess the data reliability from both blood sampling sites. In a second experiment, 14 adults performed a 20-min seated and a 20-min supine rest to assess for the effect of posture on haematological parameters. Results: Haemoglobin mass (CAP = 948.8 ± 156.8 g; VEN = 943.4 ± 157.3 g, p = 0.108) and intravascular volume (CAP = 6.5 ± 1 L; VEN = 6.5 ± 0.9 L, p = 0.752) were statistically indifferent, had low bias (Hbmass bias = 14.45 ± 40.42 g, LoA -64.78 g-93.67 g) and were highly correlated between sampling techniques. Reliability analysis demonstrated no difference in the mean change in variables calculated from both sampling sites and good to excellent intraclass correlation coefficients (>0.700), however, typical measurement error was larger in variables measured using CAP (VEN Hbmass TE% = 2.1%, CAP Hbmass TE% = 5.5%). The results indicate that a supine rest prior to the rebreathing protocol would have a significant effect on haemoglobin concentration and haematocrit values compared to a seated rest, with no effect on carboxyhaemoglobin %. Conclusion: The present study demonstrates that CAP and VEN were comparable for the calculation of Hbmass and intravascular volumes in terms of accuracy. However, reduced reliability and increased error in the CAP variables indicates that there are methodological considerations to address when deciding which blood drawing technique to utilise. To reduce this CAP error, increased replicate analyses are required.
Collapse
Affiliation(s)
- Joshua T. Royal
- Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, Ljubljana, Slovenia,Jozef Stefan International Postgraduate School, Ljubljana, Slovenia
| | - Jason T. Fisher
- Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, Ljubljana, Slovenia,Jozef Stefan International Postgraduate School, Ljubljana, Slovenia
| | - Tinkara Mlinar
- Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, Ljubljana, Slovenia,Jozef Stefan International Postgraduate School, Ljubljana, Slovenia
| | - Igor B. Mekjavic
- Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, Ljubljana, Slovenia,Department of Biomedical Physiology and Kinesiology, Simon Fraser University Burnaby, Burnaby, BC, Canada
| | - Adam C. McDonnell
- Department of Automation, Biocybernetics, and Robotics, Jozef Stefan Institute, Ljubljana, Slovenia,*Correspondence: Adam C. McDonnell,
| |
Collapse
|