Zhang X, He N, Zhang L, Dai T, Sun Z, Shi Y, Li S, Yu N. Application of high intensity focused ultrasound combined with nanomaterials in anti-tumor therapy. Drug Deliv 2024; 31:2342844. [PMID: 38659328 PMCID: PMC11047217 DOI: 10.1080/10717544.2024.2342844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 03/22/2024] [Indexed: 04/26/2024] Open
Abstract
High intensity focused ultrasound (HIFU) has demonstrated its safety, efficacy and noninvasiveness in the ablation of solid tumor. However, its further application is limited by its inherent deficiencies, such as postoperative recurrence caused by incomplete ablation and excessive intensity affecting surrounding healthy tissues. Recent research has indicated that the integration of nanomaterials with HIFU exhibits a promising synergistic effect in tumor ablation. The concurrent utilization of nanomaterials with HIFU can help overcome the limitations of HIFU by improving targeting and ablation efficiency, expanding operation area, increasing operation accuracy, enhancing stability and bio-safety during the process. It also provides a platform for multi-therapy and multi-mode imaging guidance. The present review comprehensively expounds upon the synergistic mechanism between nanomaterials and HIFU, summarizes the research progress of nanomaterials as cavitation nuclei and drug carriers in combination with HIFU for tumor ablation. Furthermore, this review highlights the potential for further exploration in the development of novel nanomaterials that enhance the synergistic effect with HIFU on tumor ablation.
Collapse
Affiliation(s)
- Xuehui Zhang
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Ningning He
- School of Basic Medicine, Qingdao Medical College, Qingdao University, Qingdao, China
| | - Liang Zhang
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Tong Dai
- School of Basic Medicine, Qingdao Medical College, Qingdao University, Qingdao, China
| | - Zihan Sun
- School of Basic Medicine, Qingdao Medical College, Qingdao University, Qingdao, China
| | - Yuqing Shi
- School of Basic Medicine, Qingdao Medical College, Qingdao University, Qingdao, China
| | - Shangyong Li
- School of Basic Medicine, Qingdao Medical College, Qingdao University, Qingdao, China
| | - Ning Yu
- Department of Ultrasound, The Affiliated Hospital of Qingdao University, Qingdao, China
| |
Collapse
|
2
|
Fu M, Wang Y, Wang J, Hao Y, Zeng F, Zhang Z, Du J, Long H, Yan F. Genetic Modulation of Biosynthetic Gas Vesicles for Ultrasound Imaging. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024:e2310008. [PMID: 38533968 DOI: 10.1002/smll.202310008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 03/11/2024] [Indexed: 03/28/2024]
Abstract
Gas vesicles (GVs) from microorganisms are genetically air-filled protein nanostructures, and serve as a new class of nanoscale contrast agents for ultrasound imaging. Recently, the genetically encoded GV gene clusters have been heterologously expressed in Escherichia coli, allowing these genetically engineered bacteria to be visualized in vivo in a real-time manner by ultrasound. However, most of the GV genes remained functionally uncharacterized, which makes it difficult to regulate and modify GVs for broad medical applications. Here, the impact of GV proteins on GV formation is systematically investigated. The results first uncovered that the deletions of GvpR or GvpU resulted in the formation of a larger proportion of small, biconical GVs compared to the full-length construct, and the deletion of GvpT resulted in a larger portion of large GVs. Meanwhile, the combination of gene deletions has resulted in several genotypes of ultrasmall GVs that span from 50 to 20 nm. Furthermore, the results showed that E. coli carrying the ΔGvpCRTU mutant can produce strong ultrasound contrast signals in mouse liver. In conclusion, the study provides new insights into the roles of GV proteins in GV formation and produce ultrasmall GVs with a wide range of in vivo research.
Collapse
Affiliation(s)
- Meijun Fu
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Yuanyuan Wang
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Jieqiong Wang
- Department of Rehabilitation Medicine, Huashan Hospital, Fudan University, Shanghai, 201206, China
| | - Yongsheng Hao
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Fengyi Zeng
- Department of Ultrasound, The Second People's Hospital of Shenzhen, The First Affiliated Hospital of Shenzhen University, Shenzhen, 518061, China
| | | | - Jianxiong Du
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Huan Long
- Key Laboratory of Algal Biology, Institute of Hydrobiology, Chinese Academy of Sciences, Wuhan, Hubei Province, 430072, China
| | - Fei Yan
- CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
3
|
Zhou H, Li F, Luo L, Xiong X, Zhou K, Zhu H, Zhang J, Li P. Safety of Sonazoid in Assisting High-Intensity Focused Ultrasound Ablation Therapy for Advanced Liver Malignant Lesions: A Single-Arm Clinical Study. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:134-141. [PMID: 37865612 DOI: 10.1016/j.ultrasmedbio.2023.09.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 09/19/2023] [Accepted: 09/20/2023] [Indexed: 10/23/2023]
Abstract
OBJECTIVE The aim of the study described here was to evaluate the safety of Sonazoid-assisted high-intensity focused ultrasound (HIFU) in the treatment of advanced malignant liver lesions. METHODS A single-arm study was designed to enroll participants who were diagnosed with advanced primary liver cancer or liver metastases and proposed to receive Sonazoid assistance during HIFU treatment. Serological examination was conducted within 1 wk, and side effects in each patient were monitored for 1 mo. To evaluate therapeutic efficacy, the contrast-enhanced magnetic resonance imaging was performed 1 mo after treatment, and short-term follow-up was conducted a year later. RESULTS A total of 17 participants (12 male, 5 female) with an average age of 58 y (range: 46-73 y) were enrolled, including 11 patients with hepatocellular carcinoma, 2 patients with hepatic metastasis and 4 patients with cholangiocarcinoma. The total volume of tumor mass was 111.82 (11.01-272.30) cm3. The average total ablation time for a patient was 2021 ± 1030 s, and the energy efficiency factor was 5979.7 (3108.0, 45634.5) J/cm3. Immediately after HIFU treatment, 1 patient (5.9%) achieved complete response (CR), 4 patients (23.5%) had a moderate response, 8 patients (47.1%) had partial reperfusion and 4 patients (23.5%) had stable disease (SD). The average ablation rate for all the tumors was 51.5 ± 26.7%. The level of glutamic-pyruvic transaminase (ALT) was mildly increased in 71.6% (12/17) of patients after HIFU therapy. Mean ALT values before and after treatment were 22 (14, 35) U/L and 36 (25, 41) U/L, respectively (Z = 1.947, p = 0.051). Mild or obvious edema in skin and subcutaneous soft tissues were observed in 76.5% of patients, but no serious side effects were found. Twelve months after treatment, the follow-up results revealed that 1 patient (5.8%) achieved a CR, 8 patients (47.1%) had SD and 8 patients (47.1%) had progressive disease. The estimated median time to progression was 11 mo after treatment, with a 95% confidence interval of 6, 11 for all involved patients. CONCLUSION Use of Sonazoid is safe and feasible for improving HIFU ablation efficiency during the treatment of advanced malignant liver lesions. The therapeutic efficacy of Sonazoid-assisted HIFU needs to be explored in additional controlled clinical investigations.
Collapse
Affiliation(s)
- Hang Zhou
- Department of Ultrasound & Institute of Ultrasound Imaging, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China; Department of Ultrasound, Chongqing University Cancer Hospital, Chongqing, China
| | - Fang Li
- Department of Ultrasound, Chongqing University Cancer Hospital, Chongqing, China
| | - Li Luo
- Department of Ultrasound, Chongqing University Cancer Hospital, Chongqing, China
| | - Xialin Xiong
- Department of Ultrasound & Institute of Ultrasound Imaging, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Kun Zhou
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Hui Zhu
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Jun Zhang
- Clinical Center for Tumor Therapy, The Second Affiliated Hospital, Chongqing Medical University, Chongqing, China
| | - Pan Li
- Department of Ultrasound & Institute of Ultrasound Imaging, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
| |
Collapse
|
4
|
Wolfram F, Miller D, Demi L, Verma P, Moran CM, Walther M, Mathis G, Prosch H, Kollmann C, Jenderka KV. Best Practice Recommendations for the Safe use of Lung Ultrasound. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2023; 44:516-519. [PMID: 36377189 DOI: 10.1055/a-1978-5575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
The safety of ultrasound is of particular importance when examining the lungs, due to specific bioeffects occurring at the alveolar air-tissue interface. Lung is significantly more sensitive than solid tissue to mechanical stress. The causal biological effects due to the total reflection of sound waves have also not been investigated comprehensively.On the other hand, the clinical benefit of lung ultrasound is outstanding. It has gained considerable importance during the pandemic, showing comparable diagnostic value with other radiological imaging modalities.Therefore, based on currently available literature, this work aims to determine possible effects caused by ultrasound on the lung parenchyma and evaluate existing recommendations for acoustic output power limits when performing lung sonography.This work recommends a stepwise approach to obtain clinically relevant images while ensuring lung ultrasound safety. A special focus was set on the safety of new ultrasound modalities, which had not yet been introduced at the time of previous recommendations.Finally, necessary research and training steps are recommended in order to close knowledge gaps in the field of lung ultrasound safety in the future.These recommendations for practice were prepared by ECMUS, the safety committee of the EFSUMB, with participation of international experts in the field of lung sonography and ultrasound bioeffects.
Collapse
Affiliation(s)
- Frank Wolfram
- Clinic of Thoracic and Vascular Surgery, SRH Wald-Clinic Gera, Germany
| | - Douglas Miller
- Department of Radiology, University of Michigan Health System, Ann Arbor, United States
| | - Libertario Demi
- Department of Information Engineering and Computer Science, University of Trento Department of Information Engineering and Computer Science, Povo, Italy
| | - Prashant Verma
- Department of Medical Physics, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom of Great Britain and Northern Ireland
| | - Carmel M Moran
- Centre for Cardiovascular Science, University of Edinburgh, United Kingdom of Great Britain and Northern Ireland
| | - Marcel Walther
- Mindray Medical Imaging, MINDRAY Medical Germany GmbH, Darmstadt, Germany
| | - Gebhard Mathis
- Gastroenterologie, Internistische Praxis, Rankweil, Austria
| | - Helmut Prosch
- Department of Biomedical Imaging and Image guided Therapy, Medical University of Vienna, Austria
| | - Christian Kollmann
- Center for Medical Physics & Biomedical Engineering, Medical University Vienna, Austria
| | - Klaus-Vitold Jenderka
- Department of Engineering and Natural Sciences, University of Applied Sciences Merseburg, Germany
| |
Collapse
|
5
|
Lorton O, Guillemin PC, Peloso A, M’Rad Y, Crowe LA, Koessler T, Poletti PA, Boudabbous S, Ricoeur A, Salomir R. In Vivo Thermal Ablation of Deep Intrahepatic Targets Using a Super-Convergent MRgHIFU Applicator and a Pseudo-Tumor Model. Cancers (Basel) 2023; 15:3961. [PMID: 37568777 PMCID: PMC10417404 DOI: 10.3390/cancers15153961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 07/28/2023] [Accepted: 08/01/2023] [Indexed: 08/13/2023] Open
Abstract
BACKGROUND HIFU ablation of liver malignancies is particularly challenging due to respiratory motion, high tissue perfusion and the presence of the rib cage. Based on our previous development of a super-convergent phased-array transducer, we aimed to further investigate, in vivo, its applicability to deep intrahepatic targets. METHODS In a series of six pigs, a pseudo-tumor model was used as target, visible both on intra-operatory MRI and post-mortem gross pathology. The transcostal MRgHIFU ablation was prescribed coplanar with the pseudo-tumor, either axial or sagittal, but deliberately shifted 7 to 18 mm to the side. No specific means of protection of the ribs were implemented. Post-treatment MRI follow-up was performed at D7, followed by animal necropsy and gross pathology of the liver. RESULTS The pseudo-tumor was clearly identified on T1w MR imaging and subsequently allowed the MRgHIFU planning. The peak temperature at the focal point ranged from 58-87 °C. Gross pathology confirmed the presence of the pseudo-tumor and the well-delineated MRgHIFU ablation at the expected locations. CONCLUSIONS The specific design of the transducer enabled a reliable workflow. It demonstrated a good safety profile for in vivo transcostal MRgHIFU ablation of deep-liver targets, graded as challenging for standard surgery.
Collapse
Affiliation(s)
- Orane Lorton
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
| | - Pauline Coralie Guillemin
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
| | - Andrea Peloso
- Visceral Surgery Division, University Hospitals of Geneva, 1205 Geneva, Switzerland
| | - Yacine M’Rad
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
| | | | - Thibaud Koessler
- Oncology Department, University Hospitals of Geneva, 1205 Geneva, Switzerland
| | | | - Sana Boudabbous
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
- Radiology Division, University Hospitals of Geneva, 1205 Geneva, Switzerland
| | - Alexis Ricoeur
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
- Radiology Division, University Hospitals of Geneva, 1205 Geneva, Switzerland
| | - Rares Salomir
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
- Radiology Division, University Hospitals of Geneva, 1205 Geneva, Switzerland
| |
Collapse
|
6
|
Zou YW, Ren ZG, Sun Y, Liu ZG, Hu XB, Wang HY, Yu ZJ. The latest research progress on minimally invasive treatments for hepatocellular carcinoma. Hepatobiliary Pancreat Dis Int 2023; 22:54-63. [PMID: 36041973 DOI: 10.1016/j.hbpd.2022.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 08/09/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Hepatocellular carcinoma (HCC) is the fourth leading cause of cancer-related death worldwide. Due to the high prevalence of hepatitis B virus (HBV) infection in China, the incidence of HCC in China is high, and liver cirrhosis caused by chronic hepatitis also brings great challenges to treatment. This paper reviewed the latest research progress on minimally invasive treatments for HCC, including percutaneous thermal ablation and new nonthermal ablation techniques, and introduced the principles, advantages, and clinical applications of various therapeutic methods in detail. DATA SOURCES The data of treatments for HCC were systematically collected from the PubMed, ScienceDirect, American Chemical Society and Web of Science databases published in English, using "minimally invasive" and "hepatocellular carcinoma" or "liver cancer" as the keywords. RESULTS Percutaneous thermal ablation is still a first-line strategy for the minimally invasive treatment of HCC. The effect of microwave ablation (MWA) on downgrading treatment before liver transplantation is better than that of radiofrequency ablation (RFA), while RFA is more widely used in the clinical practice. High-intensity focused ultrasound (HIFU) is mainly used for the palliative treatment of advanced liver cancer. Electrochemotherapy (ECT) delivers chemotherapeutic drugs to the target cells while reducing the blood supply around HCC. Irreversible electroporation (IRE) uses a microsecond-pulsed electric field that induces apoptosis and necrosis and triggers a systemic immune response. The nanosecond pulsed electric field (nsPEF) has achieved a good response in the ablation of mice with HCC, but it has not been reported in China for the treatment of human HCC. CONCLUSIONS A variety of minimally invasive treatments provide a sufficient survival advantage for HCC patients. Nonthermal ablation will lead to a new wave with its unique advantage of antitumor recurrence and metastasis.
Collapse
Affiliation(s)
- Ya-Wen Zou
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Key Laboratory of Pulsed Power Translational Medicine of Zhejiang Province, 2959 Yuhangtang Road, Hangzhou 310000, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Zhi-Gang Ren
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Key Laboratory of Pulsed Power Translational Medicine of Zhejiang Province, 2959 Yuhangtang Road, Hangzhou 310000, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Ying Sun
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Key Laboratory of Pulsed Power Translational Medicine of Zhejiang Province, 2959 Yuhangtang Road, Hangzhou 310000, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Zhen-Guo Liu
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Key Laboratory of Pulsed Power Translational Medicine of Zhejiang Province, 2959 Yuhangtang Road, Hangzhou 310000, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Xiao-Bo Hu
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Hai-Yu Wang
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
| | - Zu-Jiang Yu
- Department of Infectious Diseases, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; Gene Hospital of Henan Province; Precision Medicine Center, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China.
| |
Collapse
|
7
|
Mansur A, Garg T, Shrigiriwar A, Etezadi V, Georgiades C, Habibollahi P, Huber TC, Camacho JC, Nour SG, Sag AA, Prologo JD, Nezami N. Image-Guided Percutaneous Ablation for Primary and Metastatic Tumors. Diagnostics (Basel) 2022; 12:diagnostics12061300. [PMID: 35741109 PMCID: PMC9221861 DOI: 10.3390/diagnostics12061300] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 05/20/2022] [Accepted: 05/22/2022] [Indexed: 02/06/2023] Open
Abstract
Image-guided percutaneous ablation methods have been further developed during the recent two decades and have transformed the minimally invasive and precision features of treatment options targeting primary and metastatic tumors. They work by percutaneously introducing applicators to precisely destroy a tumor and offer much lower risks than conventional methods. There are usually shorter recovery periods, less bleeding, and more preservation of organ parenchyma, expanding the treatment options of patients with cancer who may not be eligible for resection. Image-guided ablation techniques are currently utilized for the treatment of primary and metastatic tumors in various organs including the liver, pancreas, kidneys, thyroid and parathyroid, prostate, lung, bone, and soft tissue. This article provides a brief review of the various imaging modalities and available ablation techniques and discusses their applications and associated complications in various organs.
Collapse
Affiliation(s)
| | - Tushar Garg
- Division of Vascular and Interventional Radiology, Russell H Morgan Department of Radiology and Radiological Science, The Johns Hopkins Hospital, Baltimore, MD 21287, USA; (T.G.); (C.G.)
| | - Apurva Shrigiriwar
- Division of Gastroenterology and Hepatology, The Johns Hopkins Hospital, Baltimore, MD 21287, USA;
| | - Vahid Etezadi
- Division of Vascular and Interventional Radiology, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD 21201, USA;
| | - Christos Georgiades
- Division of Vascular and Interventional Radiology, Russell H Morgan Department of Radiology and Radiological Science, The Johns Hopkins Hospital, Baltimore, MD 21287, USA; (T.G.); (C.G.)
| | - Peiman Habibollahi
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA;
| | - Timothy C. Huber
- Vascular and Interventional Radiology, Dotter Department of Interventional Radiology, Oregon Health and Science University, Portland, OR 97239, USA;
| | - Juan C. Camacho
- Department of Clinical Sciences, College of Medicine, Florida State University, Tallahassee, FL 32306, USA;
- Vascular and Interventional Radiology, Radiology Associates of Florida, Sarasota, FL 34239, USA
| | - Sherif G. Nour
- Department of Radiology and Medical Imaging, Florida State University College of Medicine, Gainesville, FL 32610, USA;
| | - Alan Alper Sag
- Division of Vascular and Interventional Radiology, Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA;
| | - John David Prologo
- Division of Vascular and Interventional Radiology, Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA 30322, USA;
| | - Nariman Nezami
- Division of Vascular and Interventional Radiology, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD 21201, USA;
- Experimental Therapeutics Program, University of Maryland Marlene and Stewart Greenebaum Comprehensive Cancer Center, Baltimore, MD 21201, USA
- Correspondence: or
| |
Collapse
|
8
|
Holman R, Lorton O, Guillemin PC, Desgranges S, Santini F, Preso DB, Farhat M, Contino-Pépin C, Salomir R. Perfluorocarbon emulsion enhances MR-ARFI displacement and temperature in vitro: Evaluating the response with MRI, NMR, and hydrophone. Front Oncol 2022; 12:1025481. [PMID: 36713528 PMCID: PMC9880467 DOI: 10.3389/fonc.2022.1025481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 11/18/2022] [Indexed: 01/15/2023] Open
Abstract
Sonosensitive perfluorocarbon F8TAC18-PFOB emulsion is under development to enhance heating, increase thermal contrast, and reduce treatment times during focused ultrasound tumor ablation of highly perfused tissue. The emulsion previously showed enhanced heating during ex vivo and in vitro studies. Experiments were designed to observe the response in additional scenarios by varying focused ultrasound conditions, emulsion concentrations, and surfactants. Most notably, changes in acoustic absorption were assessed with MR-ARFI. Phantoms were developed to have thermal, elastic, and relaxometry properties similar to those of ex vivo pig tissue. The phantoms were embedded with varying amounts of F8TAC18-PFOB emulsion or lecithin-PFOB emulsion, between about 0.0-0.3% v:w, in 0.05% v:w increments. MR-ARFI measurements were performed using a FLASH-ARFI-MRT sequence to obtain simultaneous displacement and temperature measurements. A Fabry-Perot hydrophone was utilized to observe the acoustic emissions. Susceptibility-weighted imaging and relaxometry mapping were performed to observe concentration-dependent effects. 19F diffusion-ordered spectroscopy NMR was used to measure the diffusion coefficient of perfluorocarbon droplets in a water emulsion. Increased displacement and temperature were observed with higher emulsion concentration. In semi-rigid MR-ARFI phantoms, a linear response was observed with low-duty cycle MR-ARFI sonications and a mono-exponential saturating response was observed with sustained sonications. The emulsifiers did not have a significant effect on acoustic absorption in semi-rigid gels. Stable cavitation might also contribute to enhanced heating.
Collapse
Affiliation(s)
- Ryan Holman
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Orane Lorton
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Pauline C Guillemin
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Stéphane Desgranges
- Avignon Université, Equipe Systèmes Amphiphiles bioactifs et Formulations Eco-compatibles, Unité Propre de Recherche et d'Innovation (UPRI), Avignon, France
| | - Francesco Santini
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Davide Bernardo Preso
- Institute of Mechanical Engineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Mohamed Farhat
- Institute of Mechanical Engineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Christiane Contino-Pépin
- Avignon Université, Equipe Systèmes Amphiphiles bioactifs et Formulations Eco-compatibles, Unité Propre de Recherche et d'Innovation (UPRI), Avignon, France
| | - Rares Salomir
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Radiology Department, University Hospitals of Geneva, Geneva, Switzerland
| |
Collapse
|
9
|
Chen J, Nan Z, Zhao Y, Zhang L, Zhu H, Wu D, Zong Y, Lu M, Ilovitsh T, Wan M, Yan K, Feng Y. Enhanced HIFU Theranostics with Dual-Frequency-Ring Focused Ultrasound and Activatable Perfluoropentane-Loaded Polymer Nanoparticles. MICROMACHINES 2021; 12:mi12111324. [PMID: 34832737 PMCID: PMC8621746 DOI: 10.3390/mi12111324] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/19/2021] [Accepted: 10/25/2021] [Indexed: 02/06/2023]
Abstract
High-intensity focused ultrasound (HIFU) has been widely used in tumor ablation in clinical settings. Meanwhile, there is great potential to increase the therapeutic efficiency of temporary cavitation due to enhanced thermal effects and combined mechanical effects from nonlinear vibration and collapse of the microbubbles. In this study, dual-frequency (1.1 and 5 MHz) HIFU was used to produce acoustic droplet vaporization (ADV) microbubbles from activatable perfluoropentane-loaded polymer nanoparticles (PFP@Polymer NPs), which increased the therapeutic outcome of the HIFU and helped realize tumor theranostics with ultrasound contrast imaging. Combined with PFP@Polymer NPs, dual-frequency HIFU changed the shape of the damage lesion and reduced the acoustic intensity threshold of thermal damage significantly, from 216.86 to 62.38 W/cm2. It produced a nearly 20 °C temperature increase in half the irradiation time and exhibited a higher tumor inhibition rate (84.5% ± 3.4%) at a low acoustic intensity (1.1 MHz: 23.77 W/cm2; 5 MHz: 0.35 W/cm2) in vitro than the single-frequency HIFU (60.2% ± 11.9%). Moreover, compared with the traditional PFP@BSA NDs, PFP@Polymer NPs showed higher anti-tumor efficacy (81.13% vs. 69.34%; * p < 0.05) and better contrast-enhanced ultrasound (CEUS) imaging ability (gray value of 57.53 vs. 30.67; **** p < 0.0001), probably benefitting from its uniform and stable structure. It showed potential as a highly efficient tumor theranostics approach based on dual-frequency HIFU and activatable PFP@Polymer NPs.
Collapse
Affiliation(s)
- Junjie Chen
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Zhezhu Nan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Yubo Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Lei Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Hongrui Zhu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Daocheng Wu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Yujin Zong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Mingzhu Lu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Tali Ilovitsh
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Mingxi Wan
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
| | - Kai Yan
- College of Bioresources Chemical and Materials Engineering, Shaanxi University of Science and Technology, Xi’an 710021, China
- Correspondence: (K.Y.); (Y.F.)
| | - Yi Feng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi′an Jiaotong University, Xi′an 710049, China; (J.C.); (Z.N.); (Y.Z.); (L.Z.); (H.Z.); (D.W.); (Y.Z.); (M.L.); (M.W.)
- Correspondence: (K.Y.); (Y.F.)
| |
Collapse
|
10
|
Biological Tissue Damage Monitoring Method Based on IMWPE and PNN during HIFU Treatment. INFORMATION 2021. [DOI: 10.3390/info12100404] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Biological tissue damage monitoring is an indispensable part of high-intensity focused ultrasound (HIFU) treatment. As a nonlinear method, multi-scale permutation entropy (MPE) is widely used in the monitoring of biological tissue. However, the traditional MPE method neglects the amplitude information when calculating the time series complexity, and the stability of MPE is poor due to the defects in the coarse-grained process. In order to solve the above problems, the method of improved coarse-grained multi-scale weighted permutation entropy (IMWPE) is proposed in this paper. Compared with the MPE, the IMWPE method not only includes the amplitude of signal when calculating the signal complexity, but also improves the stability of entropy value. The IMWPE method is applied to the HIFU echo signals during HIFU treatment, and the probabilistic neural network (PNN) is used for monitoring the biological tissue damage. The results show that compared with multi-scale sample entropy (MSE)-PNN and MPE-PNN methods, the proposed IMWPE-PNN method can correctly identify all the normal tissues, and can more effectively identify damaged tissues and denatured tissues. The recognition rate for the three kinds of biological tissues is higher, up to 96.7%. This means that the IMWPE-PNN method can better monitor the status of biological tissue damage during HIFU treatment.
Collapse
|