1
|
Frossard L. Trends and Opportunities in Health Economic Evaluations of Prosthetic Care Innovations. CANADIAN PROSTHETICS & ORTHOTICS JOURNAL 2021; 4:36364. [PMID: 37615000 PMCID: PMC10443521 DOI: 10.33137/cpoj.v4i2.36364] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Overcoming obstacles to prosthetic fittings requires frequent tryouts of sockets and components. Repetitions of interventions are upsetting for users and place substantial economic burden on healthcare systems. Encouraging prosthetic care innovations capable of alleviating clinical and financial shortcomings of socket-based solutions is essential. Nonetheless, evidence of socio-economic benefits of an innovation are required to facilitate access to markets. Unfortunately, complex decisions must be made when allocating resources toward the most relevant health economic evaluation (HEE) at a given stage of development of an innovation. This paper first, aimed to show the importance and challenges of HEEs of intervention facilitating prosthetic fittings. Next, the main trends in HEEs at various phases of product development and clinical acceptance of prosthetic care innovations were outlined. Then, opportunities for a basic framework of a preliminary cost-utility analysis (CUA) during the mid-stage of development of prosthetic care innovations were highlighted. To do this, fundamental and applied health economic literature and prosthetic-specific publications were reviewed to extract and analyse the trends in HEEs of new medical and prosthetic technologies, respectively. The findings show there is consensus around the weaknesses of full CUAs (e.g., lack of timeliness, resource-intensive) and strengths of preliminary CUAs (e.g., identify evidence gaps, educate design of full CUA, fast-track approval). However, several obstacles must be overcome before preliminary CUA of prosthetic care innovations will be routinely carried out. Disparities of methods and constructs of usual preliminary CUA are barriers that could be alleviated by a more standardized framework. The paper concludes by identifying that there are opportunities for the development of a basic framework of preliminary CUA of prosthetic care innovations. Ultimately, the collaborative design of a framework could simplify selection of the methods, standardise outcomes, ease comparisons between innovations and streamline pathways for adoption. This might facilitate access to economical solutions that could improve the life of individuals suffering from limb loss.
Collapse
Affiliation(s)
- L Frossard
- YourResearchProject Pty Ltd, Brisbane, Australia
- Griffith University, Gold Coast, Australia
- University of the Sunshine Coast, Maroochydore, Australia
- Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
2
|
Clarke L, Dillon MP, Shiell A. A systematic review of health economic evaluation in orthotics and prosthetics: Part 2-orthotics. Prosthet Orthot Int 2021; 45:221-234. [PMID: 33856150 DOI: 10.1097/pxr.0000000000000003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Accepted: 10/22/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Health economic evaluations (HEEs) in orthotics are in their infancy. Identification of evidence gaps and method design issues will inform the design of future HEEs that advance knowledge and contributes to policy and investment decisions. OBJECTIVES The aim of this systematic review was to critically appraise the existing orthotic/prosthetic health economic evaluation literature and therefore determine evidence gaps, critical method design issues, and the extent to which the literature informs orthotic policy and investment decisions. STUDY DESIGN Systematic review. METHODS A range of databases were searched using intervention- and HEE-related terms. The Consolidated Health Economic Checklist-Extended and the Checklist for Health Economic Evaluation Reporting Standards were used to identify issues with method design and reporting. RESULTS Nine orthotic HEEs were narrowly focused on the cost-effectiveness of low-cost orthotic devices (eg, ankle orthoses for ankle sprains). Method design (eg, cost identification and valuation) and reporting issues (eg, lack of detail about the study population) limited the extent to which this literature can inform policy and investment decisions. CONCLUSIONS HEEs comparing a wider variety of interventions are required, particularly for commonly used orthoses (eg, ankle-foot orthoses) and clinical presentations (eg, post-stroke). There are opportunities to strengthen future orthotic HEEs by adopting method design features (eg, microcosting and sensitivity analyses) as recommended by HEE appraisal and reporting tools.
Collapse
Affiliation(s)
- Leigh Clarke
- Discipline of Prosthetics and Orthotics, Department of Physiotherapy, Podiatry, Prosthetics and Orthotics, School of Allied Health, Human Services and Sports, La Trobe University, Melbourne, Victoria, Australia
- The Australian Orthotic Prosthetic Association, Camberwell, VIC, Australia
| | - Michael P Dillon
- Discipline of Prosthetics and Orthotics, Department of Physiotherapy, Podiatry, Prosthetics and Orthotics, School of Allied Health, Human Services and Sports, La Trobe University, Melbourne, Victoria, Australia
| | - Alan Shiell
- Department of Public Health, School of Psychology and Public Health, La Trobe University, Melbourne, Victoria, Australia
| |
Collapse
|
3
|
Donnelley CA, Shirley C, von Kaeppler EP, Hetherington A, Albright PD, Morshed S, Shearer DW. Cost Analyses of Prosthetic Devices: A Systematic Review. Arch Phys Med Rehabil 2021; 102:1404-1415.e2. [PMID: 33711275 DOI: 10.1016/j.apmr.2021.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 01/22/2021] [Accepted: 02/03/2021] [Indexed: 10/22/2022]
Abstract
OBJECTIVE To synthesize extant literature on the cost-effectiveness of prosthetic interventions and explore applicability to low- and middle-income country (LMIC) settings. DATA SOURCES A systematic literature review using subject headings including "prosthetics," "amputation," and "cost analysis" was performed with PubMed, Embase, and Web of Science search engines, yielding 1194 articles. An additional 22 articles were identified via backward citation searching for 1144 total after duplicate removal. The search was last run in May of 2019. STUDY SELECTION Studies were included if they conducted an economic analysis of an upper or lower extremity prosthetic device. Studies were excluded if (1) full text was unavailable in English; (2) study was a systematic review or meta-analysis; or (3) study did not have a prosthetic comparison group. Using DistillerSR software, 2 authors independently conducted title and abstract screening. One author conducted full-text screening. The proportion of initially identified studies that met final inclusion criteria was 1% (12 of 1144). DATA EXTRACTION Data were dually extracted by 2 authors and reviewed by 3 additional authors. DATA SYNTHESIS All included studies (N=12) examined lower extremity amputations comparing advanced technology. No studies were conducted in LMICs. Comparable data between studies demonstrated (1) the cost-effectiveness of microprocessor- over nonmicroprocessor-controlled knees for transfemoral amputation in high-income settings; (2) equivocal findings regarding osseointegrated vs socket-suspended prostheses; and (3) increased cost for ICEX and modular socket systems over patellar tendon-bearing socket systems with no functional improvement. CONCLUSIONS There are few prosthetic cost analyses in the literature. Additional analyses are needed to determine the direct and indirect costs associated with prosthetic acquisition, fitting, and maintenance; the costs of amputee rehabilitation; and long-term economic and quality-of-life benefits. Such studies may guide future prosthetic and rehabilitative care, especially in resource-austere settings where prosthetic needs are greatest.
Collapse
Affiliation(s)
- Claire A Donnelley
- Department of Orthopaedic Surgery, Institute for Global Orthopaedics and Traumatology, University of California, San Francisco, San Francisco, CA
| | - Corin Shirley
- Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, CA
| | - Ericka P von Kaeppler
- Department of Orthopaedic Surgery, Institute for Global Orthopaedics and Traumatology, University of California, San Francisco, San Francisco, CA
| | - Alexander Hetherington
- Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, CA
| | | | - Saam Morshed
- Department of Orthopaedic Surgery, Institute for Global Orthopaedics and Traumatology, University of California, San Francisco, San Francisco, CA
| | - David W Shearer
- Department of Orthopaedic Surgery, Institute for Global Orthopaedics and Traumatology, University of California, San Francisco, San Francisco, CA.
| |
Collapse
|
4
|
Clarke L, Dillon MP, Shiell A. A systematic review of health economic evaluations in orthotics and prosthetics: Part 1 - prosthetics. Prosthet Orthot Int 2021; 45:62-75. [PMID: 33834746 DOI: 10.1177/0309364620935310] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND The extent to which current prosthetic health economic evaluations inform healthcare policy and investment decisions is unclear. To further the knowledge in this area, existing evidence gaps and method design issues must be identified, thereby informing the design of future research. OBJECTIVES The aim of this systematic review was to identify evidence gaps, critical method design and reporting issues and determine the extent to which the literature informs a wide range of policy and investment decisions. STUDY DESIGN Systematic review. METHODS A range of databases were searched using intervention- and health economic evaluation-related terms. Issues with methodological design and reporting were evaluated using the Consolidated Health Economic Checklist - Extended and the Checklist for Health Economic Evaluation Reporting Standards. RESULTS The existing health economic evaluation literature was narrowly focused on informing within-participant component decisions. There were common method design (e.g. time horizon too short) and reporting issues (e.g. competing intervention descriptions) that limit the extent to which this literature can inform policy and investment decisions. CONCLUSION There are opportunities to conduct a wider variety of health economic evaluations to support within- and across-sector policy and investment decisions. Changes to aspects of the method design and reporting are encouraged for future research in order to improve the rigour of the health economic evaluation evidence. CLINICAL RELEVANCE This systematic review will inform the clinical focus and method design of future prosthetic health economic evaluations. It will also guide readers and policy-makers in their interpretation of the current literature and their understanding of the extent to which the current literature can be used to inform policy and investment decisions.
Collapse
Affiliation(s)
- Leigh Clarke
- Discipline of Prosthetics and Orthotics, Department of Physiotherapy, Podiatry, and Prosthetics and Orthotics, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia
- The Australian Orthotic Prosthetic Association, Camberwell, VIC, Australia
| | - Michael P Dillon
- Discipline of Prosthetics and Orthotics, Department of Physiotherapy, Podiatry, and Prosthetics and Orthotics, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC, Australia
| | - Alan Shiell
- Department of Public Health, School of Psychology and Public Health, La Trobe University, Melbourne, VIC, Australia
| |
Collapse
|
5
|
DeZeeuw KG, Dudek N. Orthosis Comfort Score: Establishing initial evidence of reliability and validity in ankle foot orthosis users. Prosthet Orthot Int 2019; 43:478-484. [PMID: 31378132 DOI: 10.1177/0309364619866611] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Comfort of an orthosis is an important characteristic that is likely to dictate use of and satisfaction with a device. However, instruments to assess only orthosis user comfort do not exist. The Prosthetic Socket Fit Comfort Score, developed previously for prosthesis users, may be adapted to serve this purpose. OBJECTIVES This study's purpose was to assess the validity and reliability of the Orthosis Comfort Score, a self-report instrument adapted from the Prosthetic Socket Fit Comfort Score. STUDY DESIGN This is a prospective, observational study designed to establish initial evidence of validity and reliability for an outcome measure that assesses comfort. METHODS Ankle foot orthosis users completed the Orthosis Comfort Score and two validated patient satisfaction questionnaires. An orthotist documented an assessment of fit. Post-visit Orthosis Comfort Scores were documented after the appointment and 2-4 weeks later. Orthosis Comfort Scores were compared to the patient satisfaction questionnaires, assessment of fit and orthosis use (hours per week). RESULTS There were 46 study participants. Orthosis Comfort Scores had a moderate positive correlation with their orthotist's assessment of fit, very strong positive correlations with patient satisfaction questionnaires and fair positive correlation with orthosis use (all correlations p < 0.05). CONCLUSION This study demonstrates initial evidence for the validity and reliability of the Orthosis Comfort Score in ankle foot orthosis users. CLINICAL RELEVANCE The Orthosis Comfort Score is a simple patient-reported outcome measure that can be readily incorporated into clinical practice or research study to obtain a rapid assessment of comfort. It can be used to facilitate communication about device fit, evaluate comfort over time and/or assess changes in comfort with a new device.
Collapse
Affiliation(s)
- Katrina G DeZeeuw
- University of Ottawa, Ottawa, ON, Canada.,The Ottawa Hospital Rehabilitation Centre, Ottawa, ON, Canada
| | - Nancy Dudek
- University of Ottawa, Ottawa, ON, Canada.,The Ottawa Hospital Rehabilitation Centre, Ottawa, ON, Canada
| |
Collapse
|
6
|
Laing S, Lee PVS, Lavranos J, Lythgo N. The functional, spatio-temporal and satisfaction outcomes of transtibial amputees with a hydrocast socket following an extended usage period in an under-resourced environment. Gait Posture 2018; 66:88-93. [PMID: 30170139 DOI: 10.1016/j.gaitpost.2018.08.022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Revised: 07/05/2018] [Accepted: 08/20/2018] [Indexed: 02/02/2023]
Abstract
BACKGROUND Transtibial hydrocast sockets have been shown to be a potential alternative to hand-cast patella-tendon bearing sockets, the use of which would have particular benefits in under-resourced environments. However, data concerning wearer outcomes of hard hydrocast sockets (i.e. those without silicone liners), especially over long-term usage periods, is scarce in the literature. RESEARCH QUESTIONS Are there any changes in wearer functional, spatio-temporal or satisfaction outcomes over a long usage period with a hydrocast socket? And how do the post-usage period outcomes compare with those from the wearers original prostheses? METHODS In this pre-post interventional study, the clinical outcomes of twenty-one experienced transtibial prostheses users were evaluated using widely-accepted and employed methods to assess wearer functional capacity, mobility, gait and satisfaction. The participants were fit with a hard hydrocast socket and the outcomes after an extensive usage period of 5 months were compared to the pre-usage period data following initial fitting and the data collected from the participants' original prosthetic limb. RESULTS Significant differences were found in the temporal parameters of gait, all indicating decreased reliance on the intact limb and an increased loading of the prosthetic limb with the post-usage period hydrocast socket compared to both the pre-usage period socket and the participants' original limbs. No differences in the functional capacity, mobility, spatial gait parameters or satisfaction were found between the socket conditions. SIGNIFICANCE This is the largest study to date of functional, spatio-temporal and satisfaction outcomes of hydrocast sockets following an extended usage period in an under-resourced environment.
Collapse
Affiliation(s)
- Sheridan Laing
- The Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia
| | - Peter V S Lee
- The Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Jim Lavranos
- Department of Prosthetics and Orthotics, Caulfield Hospital, Caulfield, Victoria, Australia
| | - Noel Lythgo
- School of Health and Biomedical Sciences, RMIT University, Melbourne, Victoria, Australia
| |
Collapse
|
7
|
Baars EC, Schrier E, Dijkstra PU, Geertzen JH. Prosthesis satisfaction in lower limb amputees: A systematic review of associated factors and questionnaires. Medicine (Baltimore) 2018; 97:e12296. [PMID: 30278503 PMCID: PMC6181602 DOI: 10.1097/md.0000000000012296] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 08/16/2018] [Indexed: 12/04/2022] Open
Abstract
BACKGROUND Factors influencing patient satisfaction with a transtibial prosthesis have been studied fragmentarily. The aims of this systematic review were to review the literature regarding factors of influence on patient satisfaction with a transtibial prosthesis, to report satisfaction scores, to present an overview of questionnaires used to assess satisfaction and examine how these questionnaires operationalize satisfaction. METHODS A literature search was performed in PubMed, Embase, PsycInfo, CINAHL, Cochrane, and Web of Knowledge databases up to February 2018 to identify relevant studies. RESULTS Twelve of 1832 studies met the inclusion criteria. Sample sizes ranged from 14 to 581 participants, mean age ranged from 18 to 70 years, and time since amputation ranged from 3 to 39 years. Seven questionnaires assessed different aspects of satisfaction. Patient satisfaction was influenced by appearance, properties, fit, and use of the prosthesis, as well as aspects of the residual limb. These influencing factors were not relevant for all amputee patients and were related to gender, etiology, liner use, and level of amputation. No single factor was found to significantly influence satisfaction or dissatisfaction. Significant associations were found between satisfaction and gender, etiology, liner use, and level of amputation. CONCLUSION Relevance of certain factors for satisfaction was related to specific amputee patient groups. Questionnaires assessing satisfaction use different operationalizations, making comparisons between studies difficult.
Collapse
Affiliation(s)
| | - Ernst Schrier
- Department of Rehabilitation Medicine, Center for Rehabilitation
| | - Pieter U. Dijkstra
- Department of Rehabilitation Medicine, Center for Rehabilitation
- Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | | |
Collapse
|
8
|
Giesberts B, Ennion L, Hjelmstrom O, Karma A, Lechler K, Hekman E, Bergsma A. The modular socket system in a rural setting in Indonesia. Prosthet Orthot Int 2018; 42:336-343. [PMID: 29153044 PMCID: PMC5960840 DOI: 10.1177/0309364617741917] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Prosthetic services are inaccessible to people living in rural areas. Systems like the modular socket system have the potential to be fabricated outside of the prosthetic workshop. OBJECTIVES This study aimed to evaluate the patient's performance and satisfaction with the use of the modular socket system, and the technical feasibility of its implementation in a rural setting. STUDY DESIGN A quantitative longitudinal descriptive study design was followed. METHODS A total of 15 persons with a lower limb amputation were fitted with the modular socket system and followed over 4-6 months. Performance was measured using a 2-min walk test, 10-m walk test and mobility and function questionnaire. Satisfaction was measured by the Socket Fit Comfort Score, Prosthesis Evaluation Questionnaire and EuroQoL 5 Dimensions 5 Levels. Notes on technical feasibility were taken at the moment of fitting ( t0), at 1-3 months post fitting ( t1) and at the end evaluation at 4-6 months post fitting ( t2). RESULTS Performance did not change between t0 and t2. The comfort of the socket fit reduced between t0 and t2. Satisfaction with prosthesis and general health status stayed constant over time. The average fitting-time for the modular socket system was 6.4 h. CONCLUSION The modular socket system can be considered a useful alternative for use in rural settings. Clinical relevance The use of the modular socket system is feasible and can improve accessibility to prosthetic technology in rural areas. Experienced prosthetic users were satisfied with the performance and the device. The shorter manufacturing time and use of only hand-held tools makes it an ideal alternative for use in remote and rural settings.
Collapse
Affiliation(s)
- Bob Giesberts
- Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands,Bob Giesberts, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands.
| | - Liezel Ennion
- Department of Physiotherapy, University of the Western Cape, Bellville, South Africa
| | | | - Agusni Karma
- Department of Prosthetic and Orthotic, Polytechnic of Health, Indonesian Ministry of Health, Jakarta, Indonesia
| | | | - Edsko Hekman
- Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands
| | - Arjen Bergsma
- Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands,Movendi Foundation, The Netherlands
| |
Collapse
|
9
|
Healy A, Farmer S, Pandyan A, Chockalingam N. A systematic review of randomised controlled trials assessing effectiveness of prosthetic and orthotic interventions. PLoS One 2018; 13:e0192094. [PMID: 29538382 PMCID: PMC5851539 DOI: 10.1371/journal.pone.0192094] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 01/16/2018] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Assistive products are items which allow older people and people with disabilities to be able to live a healthy, productive and dignified life. It has been estimated that approximately 1.5% of the world's population need a prosthesis or orthosis. OBJECTIVE The objective of this study was to systematically identify and review the evidence from randomized controlled trials assessing effectiveness and cost-effectiveness of prosthetic and orthotic interventions. METHODS Literature searches, completed in September 2015, were carried out in fourteen databases between years 1995 and 2015. The search results were independently screened by two reviewers. For the purpose of this manuscript, only randomized controlled trials which examined interventions using orthotic or prosthetic devices were selected for data extraction and synthesis. RESULTS A total of 342 randomised controlled trials were identified (319 English language and 23 non-English language). Only 4 of these randomised controlled trials examined prosthetic interventions and the rest examined orthotic interventions. These orthotic interventions were categorised based on the medical conditions/injuries of the participants. From these studies, this review focused on the medical condition/injuries with the highest number of randomised controlled trials (osteoarthritis, fracture, stroke, carpal tunnel syndrome, plantar fasciitis, anterior cruciate ligament, diabetic foot, rheumatoid and juvenile idiopathic arthritis, ankle sprain, cerebral palsy, lateral epicondylitis and low back pain). The included articles were assessed for risk of bias using the Cochrane Risk of Bias tool. Details of the clinical population examined, the type of orthotic/prosthetic intervention, the comparator/s and the outcome measures were extracted. Effect sizes and odds ratios were calculated for all outcome measures, where possible. CONCLUSIONS At present, for prosthetic and orthotic interventions, the scientific literature does not provide sufficient high quality research to allow strong conclusions on their effectiveness and cost-effectiveness.
Collapse
Affiliation(s)
- Aoife Healy
- School of Life Sciences and Education, Staffordshire University, Stoke On Trent, United Kingdom
| | - Sybil Farmer
- School of Life Sciences and Education, Staffordshire University, Stoke On Trent, United Kingdom
| | - Anand Pandyan
- School of Life Sciences and Education, Staffordshire University, Stoke On Trent, United Kingdom
- School of Health & Rehabilitation, Keele University, Keele, United Kingdom
| | - Nachiappan Chockalingam
- School of Life Sciences and Education, Staffordshire University, Stoke On Trent, United Kingdom
| |
Collapse
|
10
|
Laing S, Lythgo N, Lavranos J, Lee PVS. Transtibial Prosthetic Socket Shape in a Developing Country: A study to compare initial outcomes in Pressure Cast hydrostatic and Patella Tendon Bearing designs. Gait Posture 2017; 58:363-368. [PMID: 28869901 DOI: 10.1016/j.gaitpost.2017.08.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2016] [Revised: 07/06/2017] [Accepted: 08/11/2017] [Indexed: 02/02/2023]
Abstract
This study compared the physical function and comfort level of patients with unilateral transtibial amputation after being fitted with a hand-cast Patella Tendon Bearing (PTB) socket and a pressure-cast (PCAST) hydrocast socket. The latter technique aims to reduce the skill dependency currently required for socket manufacture and fit. The study was conducted at the Vietnamese Training Centre for Orthopaedic Technologies and involved seventeen Vietnamese participants with unilateral transtibial amputation, all of whom were long term users of prosthetics. All participants were fitted with two sockets manufactured using both hand-cast and PCAST techniques with International Committee of the Red Cross components. Walking tests (timed up and go test and six-minute-walk-test), spatio-temporal gait analyses and subjective comfort assessments were completed after a short acclimatisation period with each socket. The participant-preferred socket was also noted. No significant differences were found for the measures of mobility, functional capacity, spatio-temporal gait parameters, gait symmetry, perceived comfort or participant socket preference. The results show the initial patient outcomes are similar when participants are fitted with a hand-cast PTB socket and a PCAST hydrocast sockets. Future work should confirm these findings in a longer trial.
Collapse
Affiliation(s)
- Sheridan Laing
- The Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia
| | - Noel Lythgo
- School of Health and Biomedical Sciences, RMIT University, Melbourne, Victoria, Australia
| | - Jim Lavranos
- Department of Prosthetics and Orthotics, Caulfield Hospital, Caulfield, Victoria, Australia
| | - Peter Vee Sin Lee
- The Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| |
Collapse
|
11
|
Abstract
BACKGROUND The liner is an integral part of a transtibial prosthesis designed to protect the residual limb, enhance comfort and provide suspension. Literature is difficult to interpret and use given the variety of interventions, outcome measures and method designs. Critical appraisal and synthesis of the evidence is needed to help inform decisions about liner prescription based on the user experience. OBJECTIVES To critically appraise and synthesise research describing the user experience of transtibial prosthetic liners. STUDY DESIGN Systematic review. METHODS A comprehensive suite of databases were searched using terms related to amputation level, liner type and user experience. Included studies were in English and measured the first-person experience of using a transtibial liner. Studies were appraised using the McMaster University Critical Review Forms. RESULTS A total of 18 articles met the inclusion criteria. While the quality of the evidence has improved over time, a number of common issues (e.g. sampling bias, validity of outcome measures, incorrect inferential analysis) reduce our ability to differentiate between the user experience of different transtibial liners. CONCLUSION There is insufficient research to differentiate between the user experience of different transtibial liners. High-quality research is needed to inform decisions about liner prescription based on the user experience. Clinical relevance The available evidence suggests that the user experience of commonly reported problems (e.g. sweating) may be very similar between different liners. Aspects of the user experience that differ most between liners (e.g. unwanted noises, rotation within the socket) can help focus attention on what matters most when discussing prescription.
Collapse
|
12
|
Highsmith MJ, Kahle JT, Lewandowski A, Klenow TD, Orriola JJ, Miro RM, Hill OT, Raschke SU, Orendurff MS, Highsmith JT, Sutton BS. ECONOMIC EVALUATIONS OF INTERVENTIONS FOR TRANSTIBIAL AMPUTEES: A SCOPING REVIEW OF COMPARATIVE STUDIES. TECHNOLOGY AND INNOVATION 2016; 18:85-98. [PMID: 28066519 DOI: 10.21300/18.2-3.2016.85] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Transtibial amputation (TTA) is life-altering emotionally, functionally, and economically. The economic impact to all stakeholders is largely unknown, as is the cost-effectiveness of prosthetic intervention. This scoping report's purpose was to determine if there is sufficient evidence to conduct a formal systematic review or meta-analysis in any particular prosthetic intervention area and to determine if any evidence statements could be synthesized relative to economic evaluation of interventions provided to patients with TTA. The scoping review revealed six articles representing three topical areas of transtibial care: Care Models, Prosthetic Treatment, and Prosthetic Sockets. All six articles were cost-identification or cost-consequence design and included a total of 704 subjects. Presently, it can be concluded with moderate confidence that specific weight-bearing and total-contact sockets for transtibial amputees are functionally and economically equivalent in the short term when costs, delivery time, and all stakeholder perspectives are considered. Long-term socket outcomes are relatively unexplored. Further primary research is needed beyond this to determine cost-effectiveness for other areas of transtibial prosthetic care although clinical outcomes are somewhat established through systematic review and meta-analysis in other areas of care. Conversely, evaluation of narrative economic reports relative to transtibial care may be sufficient to warrant further analysis. Guidance from the profession may also be useful in devising a strategy for how to assure economic analyses are a routine element of future prosthetic science.
Collapse
Affiliation(s)
- M Jason Highsmith
- School of Physical Therapy & Rehabilitation Sciences, University of South Florida, Tampa, FL, USA; Extremity Trauma & Amputation Center of Excellence (EACE), U.S. Department of Veterans Affairs, Tampa, FL, USA; 319 Minimal Care Detachment, U.S. Army Reserves, Pinellas Park, FL, USA
| | - Jason T Kahle
- OP Solutions, Tampa, FL, USA; Prosthetic Design + Research, Tampa, FL, USA
| | | | - Tyler D Klenow
- Prosthetics and Sensory Aids Service, James A. Haley Veterans' Hospital, Tampa, FL, USA
| | - John J Orriola
- Shimberg Health Sciences Library, University of South Florida, Tampa, FL, USA
| | - Rebecca M Miro
- School of Physical Therapy & Rehabilitation Sciences, University of South Florida, Tampa, FL, USA
| | - Owen T Hill
- Extremity Trauma & Amputation Center of Excellence (EACE), San Antonio Medical Center, Fort Sam Houston, TX, USA
| | - Sylvia Ursula Raschke
- Center for Rehabilitation Engineering and Technology that Enables (CREATE), BCIT Technology Centre, Burnaby, Canada
| | - Michael S Orendurff
- Motion & Sports Performance Laboratory, Lucile Packard Children's Hospital Stanford, Palo Alto, CA, USA
| | - James T Highsmith
- Dermatology Service, James A. Haley Veterans' Hospital, Tampa, FL, USA; Dermatology Surgery Institute, Lutz, FL, USA
| | - Bryce S Sutton
- Center of Innovation on Disability and Rehabilitation Research (CINDRR-TPA), James A. Haley Veterans' Hospital, Tampa, FL, USA
| |
Collapse
|
13
|
Safari MR, Meier MR. Systematic review of effects of current transtibial prosthetic socket designs--Part 2: Quantitative outcomes. ACTA ACUST UNITED AC 2016; 52:509-26. [PMID: 26436733 DOI: 10.1682/jrrd.2014.08.0184] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 04/14/2015] [Indexed: 11/05/2022]
Abstract
This review is an attempt to untangle the complexity of transtibial prosthetic socket fit and perhaps find some indication of whether a particular prosthetic socket type might be best for a given situation. In addition, we identified knowledge gaps, thus providing direction for possible future research. We followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines, using medical subject headings and standard key words to search for articles in relevant databases. No restrictions were made on study design and type of outcome measure used. From the obtained search results (n = 1,863), 35 articles were included. The relevant data were entered into a predefined data form that included the Downs and Black risk of bias assessment checklist. This article presents the results from the systematic review of the quantitative outcomes (n = 27 articles). Trends indicate that vacuum-assisted suction sockets improve gait symmetry, volume control, and residual limb health more than other socket designs. Hydrostatic sockets seem to create less inconsistent socket fittings, reducing a problem that greatly influences outcome measures. Knowledge gaps exist in the understanding of clinically meaningful changes in socket fit and its effect on biomechanical outcomes. Further, safe and comfortable pressure thresholds under various conditions should be determined through a systematic approach.
Collapse
Affiliation(s)
- Mohammad Reza Safari
- Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | | |
Collapse
|
14
|
Safari MR, Meier MR. Systematic review of effects of current transtibial prosthetic socket designs—Part 1: Qualitative outcomes. ACTA ACUST UNITED AC 2015; 52:491-508. [DOI: 10.1682/jrrd.2014.08.0183] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 04/23/2015] [Indexed: 11/05/2022]
Affiliation(s)
- Mohammad Reza Safari
- Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran
| | - Margrit Regula Meier
- Department for Occupational Therapy, Prosthetics, and Orthotics, Faculty of Health Sciences, Oslo and Akershus University College of Applied Sciences, Oslo, Norway
| |
Collapse
|
15
|
Cavenett S, White S, Gomersall JS. The effectiveness of total surface bearing compared to specific surface bearing prosthetic socket design on health outcomes of adults with a trans-tibial amputation: a systematic review. ACTA ACUST UNITED AC 2014. [DOI: 10.11124/jbisrir-2014-1283] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
16
|
Hands-off and hands-on casting consistency of amputee below knee sockets using magnetic resonance imaging. ScientificWorldJournal 2013; 2013:486146. [PMID: 24348164 PMCID: PMC3853133 DOI: 10.1155/2013/486146] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 09/26/2013] [Indexed: 11/17/2022] Open
Abstract
Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for intercast and intracast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semiautomatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter- and intracast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit.
Collapse
|
17
|
Delussu AS, Brunelli S, Paradisi F, Iosa M, Pellegrini R, Zenardi D, Traballesi M. Assessment of the effects of carbon fiber and bionic foot during overground and treadmill walking in transtibial amputees. Gait Posture 2013; 38:876-82. [PMID: 23702342 DOI: 10.1016/j.gaitpost.2013.04.009] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2012] [Revised: 03/30/2013] [Accepted: 04/17/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine the energy cost of walking (ECW) of a bionic foot (Proprio-Foot®) during ambulation on floor and on treadmill (at different slopes) compared to walking with a dynamic carbon fiber foot (DCF). We evaluated transtibial amputees (TTAs) perceived mobility with the prosthesis and their walking ability on stairs and ramps. METHOD TTAs were enrolled. The ECW tests were conducted on a regular floor surface and on treadmill with -5%, 0% and 12% slopes. In all conditions, TTAs were asked to walk at their own self-selected speed. Metabolic and cardiac data were collected using a portable gas analyzer. Tests were performed at six data collection points: first with a standard suction system (SSS) and the DCF; second, with the DCF after 7 weeks of using a hypobaric suspension system (HSS) with the DCF; third, after 1 h of Proprio-Foot® use together with the HSS; three more testing sessions were carried out at 30-day intervals, i.e., after 30, 60 and 90 days of Proprio-Foot® use together with the HSS. TTAs perceived mobility using the prosthesis and walking ability on stairs and ramps were assessed. RESULTS Ten TTAs completed the measurements. ECW with the Proprio-Foot® obtained in the final floor-walking test was significantly lower than ECW with the DCF (p=0.002). No significant improvements were observed for perceived mobility or walking ability. CONCLUSIONS Results suggest that use of the Proprio-Foot® can lower the ECW for TTAs in spite of its added weight compared to DCF.
Collapse
Affiliation(s)
- Anna Sofia Delussu
- Fondazione Santa Lucia IRCCS - Scientific Institute for Research, Hospitalization and Healthcare, via Ardeatina, 306, 00179 Rome, Italy.
| | | | | | | | | | | | | |
Collapse
|
18
|
Traballesi M, Delussu AS, Averna T, Pellegrini R, Paradisi F, Brunelli S. Energy cost of walking in transfemoral amputees: Comparison between Marlo Anatomical Socket and Ischial Containment Socket. Gait Posture 2011; 34:270-4. [PMID: 21684165 DOI: 10.1016/j.gaitpost.2011.05.012] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2010] [Revised: 05/17/2011] [Accepted: 05/19/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To compare energy cost of walking (ECW) and prosthesis-related perceived mobility with the Marlo Anatomical Socket (MAS(®)) and the Ischial Containment (IC) Socket. METHOD Transfemoral (TF) amputees were enrolled in the study. ECW tests were conducted inside, in a hallway with a regular floor surface. Subjects had to walk back and forth on a 61m linear course at their own self-selected speed. Metabolic and heart rate data were collected during the walking test using a portable gas analyzer. All measurements were made at steady state (SS). The tests were performed first using the IC socket and then after 30 days of MAS(®) use; the last test was carried out after 60 days of MAS(®) use. The amputees were also administered the Prosthetic Evaluation Questionnaire Mobility Section (PEQ MS) at the first and the last test to assess perceived potential for mobility using the prosthesis. RESULTS Seven long-term prosthesis users were analyzed. Their mean age was 33.9±9.3 years; all were employed, active, and used IC sockets. At the third walking test, the ECW with the MAS(®) was significantly lower than that with the IC socket (p=.016). PEQ MS data also improved significantly at the last evaluation (p<.018). CONCLUSION Results suggest that using the MAS(®), lowering the ECW and improving PEQ MS, could be a valid prosthesis design for active TF amputees compared to their usual IC socket.
Collapse
Affiliation(s)
- Marco Traballesi
- Fondazione Santa Lucia IRCCS, Scientific Institute for Research, Hospitalization and Healthcare, via Ardeatina, 306, 00179 Rome, Italy.
| | | | | | | | | | | |
Collapse
|
19
|
Sagawa Y, Turcot K, Armand S, Thevenon A, Vuillerme N, Watelain E. Biomechanics and physiological parameters during gait in lower-limb amputees: a systematic review. Gait Posture 2011; 33:511-26. [PMID: 21392998 DOI: 10.1016/j.gaitpost.2011.02.003] [Citation(s) in RCA: 121] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2010] [Revised: 02/03/2011] [Accepted: 02/06/2011] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The purpose of this systematic review was to identify which biomechanical and physiological parameters are the most relevant, commonly used, able to discriminate and/or have specific clinical relevance for the gait analysis of lower-limb amputees (LLA). METHODS We performed an electronic search via the PubMed, EMBASE and ISI Web of Knowledge databases from 1979 to May 2009. Two independent reviewers assessed the title and abstract of each identified study. The quality assessment of the full text was undertaken using a 13-item checklist divided into three levels: A, B, and C. RESULTS The literature search identified 584 abstracts to be considered. After applying the inclusion criteria, we reviewed the full text of a total of 89 articles. The mean article quality was 8±2. No A-level article was found; the primary reason was a negative score in blinded outcome assessment. Sixty-six articles (74%) corresponded to a B-level, and two articles (2%) corresponded to a C-level. Twenty-one articles (24%) did not acquire enough points to be assigned to any level. In this study, we present and discuss the most commonly used and most relevant 32 parameters. Many of the parameters found were not reported in enough studies or in enough detail to allow a useful evaluation. CONCLUSION This systematic review can help researchers compare, choose and develop the most appropriate gait evaluation protocol for their field of study, based on the articles with best scores on the criteria list and the relevance of specific biomechanical and physiological parameters.
Collapse
|
20
|
Normann E, Olsson A, Brodtkorb TH. Modular socket system versus traditionally laminated socket: a cost analysis. Prosthet Orthot Int 2011; 35:76-80. [PMID: 21515892 DOI: 10.1177/0309364610392812] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Using the new modular socket system (MSS) to produce a prosthetic socket directly on the patient has the potential of being easier and quicker to manufacture but also incurring higher costs. OBJECTIVES The purpose of the study was to compare the costs of manufacturing a transtibial prosthetic socket using either a MSS or a standard laminated socket (PC). STUDY DESIGN Concurrent controlled trial. METHODS A total of 20 patients at two orthopaedic facilities were followed with regards to the cost of manufacturing a prosthetic socket using either MSS or PC. Time aspects and material costs were considered in the cost analysis. Other factors studied include delivery time and number of visits. For the cost analysis, only direct costs pertaining to the prosthetic socket were considered. RESULTS The total cost of MSS was found to be significantly higher (p < 0.01) compared to PC. However, the production and time cost was significantly lower. Delivery time to the patient was 1 day for MSS compared to 17 days for PC. CONCLUSIONS Our study shows that the direct prosthetic cost of treating a patient using MSS is significantly higher than treating a patient using PC. However, the MSS prosthesis can be delivered significantly faster and with fewer visits. Further studies taking the full societal costs of MSS into account should therefore be performed. CLINICAL RELEVANCE This study shows that the direct prosthetic cost of treating a patient with Modular Socket System is significantly higher than treating a patient with plastercasting with standard laminated socket. However, the Modular Socket System prosthesis can be delivered significantly faster and with fewer visits.
Collapse
Affiliation(s)
- Elna Normann
- Department of Rehabilitation, School of Health Sciences, Jönköping University, Sweden
| | | | | |
Collapse
|
21
|
Rusaw D, Ramstrand N. Motion-analysis studies of transtibial prosthesis users: a systematic review. Prosthet Orthot Int 2011; 35:8-19. [PMID: 21515885 DOI: 10.1177/0309364610393060] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Three-dimensional motion analysis has been used since the beginning of the 1980s to evaluate many aspects of physical function of transtibial amputees. Despite its common use for clinical research, there is large variability in methods of capturing three-dimensional data, description of these methods, reporting of joint kinematics and interpretation of research findings. OBJECTIVES The aim of the following review is to critically examine the specific methodologies used by researchers when collecting three-dimensional kinematic data on transtibial amputees and to provide an overview of the methods used. STUDY DESIGN Systematic review. METHODS A systematic review of the literature between January 1984 and June 2009 was conducted. A total of 68 papers were identified for review based on the following criteria: experimental research design, collection of three-dimensional kinematic data of lower-extremity joints, and inclusion of transtibial amputees as experimental subjects. RESULTS A number of methodological shortcomings were identified in the papers reviewed. CONCLUSIONS The authors recommend that future studies more appropriately address the product name and number of prosthetic components used; how the position of reflective markers on the prosthesis is defined; presentation of data from both sound and affected sides; and definition of the neutral position of the ankle when reporting kinematic data. Where possible, the authors recommend use of a control group. CLINICAL RELEVANCE This paper has identified numerous sources of discrepancy and potential error in kinematic data collected on trans-tibial amputees. Clinicians and researchers should make themselves aware of these issues when collecting and interpreting gait data.
Collapse
Affiliation(s)
- David Rusaw
- Institute for Clinical Sciences, Department of Orthopaedics, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | | |
Collapse
|