1
|
Lim C, García-Montero M, Courtis A, Hainey P, Madrid-Costa D, Crooke A. Optimization of the Oxygen Permeability of Non-Silicone Hydrogel Contact Lenses Through Crosslinking Modifications. Gels 2024; 10:726. [PMID: 39590082 PMCID: PMC11593662 DOI: 10.3390/gels10110726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 11/03/2024] [Accepted: 11/06/2024] [Indexed: 11/28/2024] Open
Abstract
The main weakness of non-silicone hydrogel contact lenses is their low oxygen permeability (Dk). Hence, we have tried to optimize their Dk using various concentrations and lengths of the poly (ethylene glycol) dimethacrylate crosslinker in a mixture of N,N-Dimethylacrylamide and Cyclohexyl methacrylate monomers. After synthesizing the different contact lenses, we evaluated their chemical, optical, and mechanical properties. The resultant non-silicone hydrogel contact lenses presented similar high water contents (75.69-80.60%) and adequate optical (e.g., a transmittance ranging from 85.91% to 99.91% and a refractive index between 1.3630 and 1.3740) and elongation at break (178.95-356.05%) characteristics for clinical applications. Conversely, they presented high contact angles (81.00-100.00°) and a low Young's modulus (0.066-0.167 MPa). Regarding the impact of the crosslinking modifications, the water content, contact angle, refractive index, transmittance, and Young's modulus of the synthesized lenses were slightly affected by crosslinker conditions. In contrast, the elongation at break (178.95-356.05%) and, more importantly, the oxygen permeability, which reached values of up to 73.90 Fatt units, were considerably impacted by the crosslinker conditions. To our knowledge, this study demonstrates for the first time that, in addition to water, other usual hydrogel components, like crosslinkers, can modulate the Dk of non-silicone contact lenses. It also provides a simple and scalable method to fabricate more permeable non-silicone lenses.
Collapse
Affiliation(s)
- Clara Lim
- Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain (M.G.-M.); (D.M.-C.)
- Department of Biochemistry and Molecular Biology, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
- Research and Development Group, Mark’ennovy, Widnes WA8 0RP, UK; (A.C.); (P.H.)
| | - María García-Montero
- Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain (M.G.-M.); (D.M.-C.)
- Clinical and Experimental Eye Research Group, UCM 971009, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
| | - Andrew Courtis
- Research and Development Group, Mark’ennovy, Widnes WA8 0RP, UK; (A.C.); (P.H.)
| | - Paul Hainey
- Research and Development Group, Mark’ennovy, Widnes WA8 0RP, UK; (A.C.); (P.H.)
| | - David Madrid-Costa
- Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain (M.G.-M.); (D.M.-C.)
- Clinical and Experimental Eye Research Group, UCM 971009, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
| | - Almudena Crooke
- Department of Biochemistry and Molecular Biology, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
- Clinical and Experimental Eye Research Group, UCM 971009, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
| |
Collapse
|
2
|
Ramasubramanian D, Hernández-Verdejo JL, López-Alonso JM. Influence of Contact Lens Parameters on Cornea: Biomechanical Analysis. Bioengineering (Basel) 2024; 11:966. [PMID: 39451343 PMCID: PMC11505363 DOI: 10.3390/bioengineering11100966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Revised: 09/22/2024] [Accepted: 09/25/2024] [Indexed: 10/26/2024] Open
Abstract
This study presents a finite element analysis to model ocular biomechanics and the interactions between the human eye and contact lenses in the closed-eye condition. The closed-eye state, where the eyelids are fully shut, presents challenges for experimental measurements due to the invasive nature of accessing and analysing the contact lens and corneal interface, making simulation tools valuable for accurate characterisation. The primary objective of this study was to examine how CLs fold and twist and their impact on the cornea when the eye is closed. The secondary aim of this study was to assess how crucial contact lens parameters (Young's modulus, base curve, and diameter) influence corneal stress distribution and the overall fit of the lens on the eye. The findings show that increasing Young's modulus significantly reduces corneal stress and promotes uniform stress distribution, making it the most influential factor for wearer comfort and safety. While base curve and diameter variations primarily affect contact area, their impact on stress distribution is minimal. This research provides insights for improving contact lens design and enhancing safety for contact lens wearers.
Collapse
Affiliation(s)
- Darshan Ramasubramanian
- Faculty of Optics and Optometry, Complutense University of Madrid, Arcos de Jalón 118, 28037 Madrid, Spain; (D.R.); (J.L.H.-V.)
- Alain Afflelou Óptico Portugal, Av. António Augusto de Aguiar 11, 1050-016 Lisbon, Portugal
| | - José Luis Hernández-Verdejo
- Faculty of Optics and Optometry, Complutense University of Madrid, Arcos de Jalón 118, 28037 Madrid, Spain; (D.R.); (J.L.H.-V.)
| | - José Manuel López-Alonso
- Faculty of Optics and Optometry, Complutense University of Madrid, Arcos de Jalón 118, 28037 Madrid, Spain; (D.R.); (J.L.H.-V.)
| |
Collapse
|
3
|
Rykowska I, Michałkiewicz O, Nowak I, Nowak R. Drug-Modified Contact Lenses-Properties, Release Kinetics, and Stability of Active Substances with Particular Emphasis on Cyclosporine A: A Review. Molecules 2024; 29:2609. [PMID: 38893485 PMCID: PMC11173495 DOI: 10.3390/molecules29112609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/27/2024] [Accepted: 05/29/2024] [Indexed: 06/21/2024] Open
Abstract
The following review focuses on the manufacturing and parameterizing of ocular drug delivery systems (DDS) using polymeric materials to create soft contact lenses. It discusses the types of drugs embedded into contact lenses, the various polymeric materials used in their production, methods for assessing the mechanical properties of polymers, and techniques for studying drug release kinetics. The article also explores strategies for investigating the stability of active substances released from contact lenses. It specifically emphasizes the production of soft contact lenses modified with Cyclosporine A (CyA) for the topical treatment of specific ocular conditions. The review pays attention to methods for monitoring the stability of Cyclosporine A within the discussed DDS, as well as investigating the influence of polymer matrix type on the stability and release of CyA.
Collapse
Affiliation(s)
- Iwona Rykowska
- Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznanskiego 8, 61-614 Poznan, Poland; (I.R.); (I.N.)
| | - Ola Michałkiewicz
- Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznanskiego 8, 61-614 Poznan, Poland; (I.R.); (I.N.)
| | - Iwona Nowak
- Faculty of Chemistry, Adam Mickiewicz University, Uniwersytetu Poznanskiego 8, 61-614 Poznan, Poland; (I.R.); (I.N.)
| | - Rafał Nowak
- Department of Ophthalmology, Military Institute of Medicine, ul. Szaserów 128, 04-141 Warsaw, Poland;
| |
Collapse
|
4
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
5
|
García-Marqués JV, Macedo-De-Araújo RJ, Cerviño A, García-Lázaro S, González-Méijome JM. Assessment of meibomian gland drop-out and visibility through a new quantitative method in scleral lens wearers: A one-year follow-up study. Cont Lens Anterior Eye 2023; 46:101571. [PMID: 34996711 DOI: 10.1016/j.clae.2021.101571] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/29/2021] [Accepted: 12/30/2021] [Indexed: 01/18/2023]
Abstract
OBJECTIVES To validate a previously developed algorithm based on the visibility of meibomian gland images obtained with Cobra fundus camera and to assess the changes in meibomian glands in scleral lens wearers over one year of lens wear. METHODS Infrared meibography was obtained from the upper eyelid using the Cobra fundus camera in forty-three volunteers (34.2 ± 10.1 years). Meibographies were classified into 3 groups: Group 1 = good subjective gland visibility and gland drop-out < 1/3 of the total area; Group 2 = low visibility and gland drop-out < 1/3; and Group 3 = low visibility and gland drop-out > 1/3. Meibomian gland visibility metrics were then calculated using the developed algorithm from the pixel intensity values of meibographies. Repeatability of new metrics and their correlations with gland drop-out were assessed. Meibographies and ocular symptoms were also assessed after 1 year of scleral lens wear in 29 subjects. RESULTS Gland drop-out percentage was not statistically different between groups 1 and 2 (p = 0.464). Nevertheless, group 1 showed higher grey pixel intensity values than the other groups. Statistically significant correlations were found between gland visibility metrics and gland drop-out percentage. Repeatability was acceptable for all metrics, coefficient of variation achieving values between 0.52 and 3.18. While ocular symptoms decreased with scleral lens wear (p < 0.001), no statistically significant differences were found in gland drop-out percentage (p = 0.157) and gland visibility metrics (p > 0.217). CONCLUSIONS The proposed method can assess meibomian gland visibility in an objective and repeatable way. Scleral lens wear appears to not adversely affect meibomian gland drop-out and visibility while might improve dry eye symptoms after one year of lens wear. These preliminary results should be confirmed with a control group.
Collapse
Affiliation(s)
| | - Rute Juliana Macedo-De-Araújo
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| | - Alejandro Cerviño
- Department of Optics and Optometry and Vision Sciences. University of Valencia, Burjassot, Spain
| | - Santiago García-Lázaro
- Department of Optics and Optometry and Vision Sciences. University of Valencia, Burjassot, Spain
| | - Jose Manuel González-Méijome
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| |
Collapse
|
6
|
García-Marqués JV, Talens-Estarelles C, García-Lázaro S, Cerviño A. The Effects of Soft Contact Lens Wear on The Tear Film and Meibomian Gland Drop-Out and Visibility. Life (Basel) 2022; 12:life12081177. [PMID: 36013356 PMCID: PMC9409842 DOI: 10.3390/life12081177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/30/2022] [Accepted: 07/31/2022] [Indexed: 11/16/2022] Open
Abstract
As contact lens (CL) wear affects the ocular surface, this cross-sectional study aims to assess the effects of soft CL wear and its duration on the tear film and meibomian gland (MG) drop-out and visibility. Thirty non-CL wearers (22.5 ± 2.3 years) and twenty-four soft CL wearers (23.8 ± 2.2 years) participated in this study. The Keratograph 5M was used to assess the ocular surface. CL users were surveyed on years of CL wear and hours per week. MG visibility was assessed using a previously developed method based on analysing pixel intensity of meibographies. The CL group showed higher gland drop-out (p < 0.001) and lower gland visibility (p < 0.022). Gland drop-out was independently associated with CL wear (p = 0.006). When gland drop-out was excluded, the relative energy of pixel intensity values showed an independent association with CL wear (p = 0.005). Prolonged hours of CL wear were associated with higher dry eye symptoms and entropy of MGs (p < 0.029). A reduction in non-invasive keratograph break-up time was associated with using CLs for ≥8 years (p = 0.030). Overall, gland drop-out was higher and gland visibility lower in soft CL wearers. New gland visibility metrics might help to assess MGs in soft CL wearers quickly and objectively.
Collapse
|