1
|
Kim JY, Yong HS, Kim TY, Kim JY, Jeon KJ, Huh JK. Volumetric changes in temporomandibular joint space following trans-oral vertical ramus osteotomy in patients with mandibular prognathism: a one-year follow-up study. Sci Rep 2024; 14:942. [PMID: 38200085 PMCID: PMC10781718 DOI: 10.1038/s41598-023-51050-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Accepted: 12/29/2023] [Indexed: 01/12/2024] Open
Abstract
This study measured and analyzed chronological changes in temporomandibular joint space volume by compartment following transoral vertical ramus osteotomy (TOVRO) using reconstructed 3-dimensional (3D) images of patients with mandibular prognathism. It included 70 joints of 35 patients who underwent TOVRO between January 2018 and December 2021. Computed tomography (CT) or cone-beam CT (CBCT) was performed before surgery (T0) and at 3 days (T1), 6 months (T2), and 12 months postoperatively (T3). These scans were then analyzed using 3D software. The volumes of the overall (Vjs), anterior (Vajs), posterior (Vpjs), medial (Vmjs), and lateral (Vljs) joint spaces were calculated at each time point. A linear mixed model and repeated-measures covariance pattern with unstructured covariance were used to evaluate significant changes in joint space volume over time. Vjs significantly increased to 134.54 ± 34.28 mm3 at T3 compared to T0 (p < 0.001). Vpjas and Vljs increased by 130.72 ± 10.07 mm3 and 109.98 ± 7.52 mm3 at T3 compared to T0, respectively (p < 0.001). However, no significant difference was observed between T0 and T2 in Vajs and Vmjs (p = 0.9999). The observed volume increases in Vpjs and Vljs appeared to contribute to the overall Vjs increase.
Collapse
Affiliation(s)
- Jae-Young Kim
- Department of Oral and Maxillofacial Surgery, Gangnam Severance Hospital, Yonsei University College of Dentistry, 211 Eonju-Ro, Gangnam-Gu, Seoul, 06273, Korea
| | - Hae-Seong Yong
- Department of Oral and Maxillofacial Surgery, Gangnam Severance Hospital, Yonsei University College of Dentistry, 211 Eonju-Ro, Gangnam-Gu, Seoul, 06273, Korea
| | - Tae-Yeong Kim
- Department of Oral and Maxillofacial Surgery, Gangnam Severance Hospital, Yonsei University College of Dentistry, 211 Eonju-Ro, Gangnam-Gu, Seoul, 06273, Korea
| | - Jun-Young Kim
- Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Kug Jin Jeon
- Department of Oral and Maxillofacial Radiology, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Jong-Ki Huh
- Department of Oral and Maxillofacial Surgery, Gangnam Severance Hospital, Yonsei University College of Dentistry, 211 Eonju-Ro, Gangnam-Gu, Seoul, 06273, Korea.
| |
Collapse
|
2
|
Ainoosah S, Farghal AE, Alzemei MS, Saini RS, Gurumurthy V, Quadri SA, Okshah A, Mosaddad SA, Heboyan A. Comparative analysis of different types of occlusal splints for the management of sleep bruxism: a systematic review. BMC Oral Health 2024; 24:29. [PMID: 38182999 PMCID: PMC10770907 DOI: 10.1186/s12903-023-03782-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 12/15/2023] [Indexed: 01/07/2024] Open
Abstract
BACKGROUND Sleep bruxism is a prevalent condition in dentistry practice, characterized by involuntary grinding or clenching of the teeth during sleep. Several therapies, including occlusal splints, have been used to manage sleep bruxism and temporomandibular disorders, including occlusal splints. This study aimed to compare the effectiveness of different occlusal splints in managing sleep bruxism. METHODS The PICO framework encompasses the characterization of the population, intervention, comparison, and pertinent outcomes. A comprehensive and systematic literature review was conducted on PubMed, Scopus, and Google Scholar to identify grey literature. The search specifically targeted scientific studies published before September 20, 2023. The Cochrane Collaboration Risk of Bias Tool assessed the accuracy of the included Randomized Control Trials (RCTs). The modified Newcastle-Ottawa Scale assessed non-randomized studies. Data were systematically extracted, synthesized, and reported thematically. RESULTS Out of the total of 808 articles that were evaluated, only 15 articles were found to meet the specified inclusion criteria. Adjustable splints, such as full-occlusion biofeedback splints, were more effective in reducing sleep bruxism episodes, improving patient-reported symptoms, and enhancing overall well-being. The impact of different occlusal sprints on electromyographic activity varies, and potential adverse effects should be considered individually. CONCLUSIONS This review provides valuable insights into the effectiveness of occlusal splints in managing sleep bruxism. The results of this study indicate that occlusal splint therapy is a viable treatment approach for sleep bruxism.
Collapse
Affiliation(s)
- Sultan Ainoosah
- Department of Substitute Dental Science, College of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Ahmed E Farghal
- Department of Substitute Dental Science, College of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Marwa Saad Alzemei
- Department of Restorative Dental Sciences, College of Dentistry, Taibah University, Madinah, Saudi Arabia
| | - Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | - Abdulmajeed Okshah
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Seyed Ali Mosaddad
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Qasr-E-Dasht Street, Shiraz, Iran.
| | - Artak Heboyan
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan, 0025, Armenia.
| |
Collapse
|
3
|
Andrade CS, de Abreu Costa L, Menechelli LG, Lemos CAA, Okamoto R, Verri FR, de Souza Batista VE. Biomechanical effects of different materials for an occlusal device on implant-supported rehabilitation in a tooth clenching situation. A 3D finite element analysis. J Prosthodont 2023. [PMID: 37675950 DOI: 10.1111/jopr.13763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 08/31/2023] [Indexed: 09/08/2023] Open
Abstract
PURPOSE The purpose of this 3D finite element analysis was to evaluate the biomechanical effects of different materials used to fabricate occlusal devices to achieve stress distribution in simulated abutment screws, dental implants, and peri-implant bone tissue in individuals who clench their teeth. MATERIALS AND METHODS Eight 3D models simulated a posterior maxillary bone block with three external hexagon implants (Ø4.0 × 7.0 mm) supporting a 3-unit screw-retained metal-ceramic prosthesis with different crown connection (splinting), and the use of an occlusal device (OD). The OD was modeled to be 2-mm thick. ANSYS 19.2 software was used to generate the finite-element models in the pre-and post-processing phases. Simulated abutment screws and dental implants were evaluated by von Mises stress maps, and simulated bone was evaluated by maximum principal stress and microstrain maps by using a finite element software program. RESULTS The highest stress values in the dental implants and screws were observed in single crowns without OD (M1). Furthermore, the highest stress values and bone tissue strain were found in single crowns without OD (M1). The simulated material for the OD did not cause many discrepancies in terms of the stress magnitude in the simulated dental implant and abutment screw for both single and splinted crowns; however, more rigid materials exhibited lower stress values. CONCLUSION The use of OD was effective in reducing stress in the simulated implants and abutment screws and stress and strain in the simulated bone tissue. The material used to simulate the OD influenced the biomechanical behavior of implant-supported fixed prostheses, whereas splints with rigid materials such as PEEK and PMMA exhibited better biomechanical behavior.
Collapse
Affiliation(s)
- Carla Souza Andrade
- Department of Prosthodontics, Presidente Prudente Dental School, University of Western São Paulo - UNOESTE, Presidente Prudente, Brazil
| | - Luy de Abreu Costa
- Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil
| | - Luana Gonçalves Menechelli
- Department of Diagnosis and Surgery, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil
| | - Cleidiel A A Lemos
- Department of Dentistry (Division of Prosthodontics), Federal University of Juiz de Fora, Campus Avançado Governador Valadares (UFJF/GV), Governador Valadares, Minas Gerais, Brazil
| | - Roberta Okamoto
- Department of Basic Sciences, Universidade Estadual Paulista Júlio de Mesquita Filho, School of Dentistry at Araçatuba, Araçatuba, Brazil
| | - Fellippo R Verri
- Department of Dental Materials and Prosthodontics, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil
| | - Victor Eduardo de Souza Batista
- Department of Prosthodontics, Presidente Prudente Dental School, University of Western São Paulo - UNOESTE, Presidente Prudente, Brazil
- Postgraduate Program in Dentistry - Implantology concentration area, Araçatuba Dental School, São Paulo State University Júlio de Mesquita Filho-UNESP, Araçatuba, Brazil
| |
Collapse
|
4
|
Benli M, Özcan M. Short-term effect of material type and thickness of occlusal splints on maximum bite force and sleep quality in patients with sleep bruxism: a randomized controlled clinical trial. Clin Oral Investig 2023; 27:4313-4322. [PMID: 37127807 DOI: 10.1007/s00784-023-05049-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Accepted: 04/26/2023] [Indexed: 05/03/2023]
Abstract
OBJECTIVE To evaluate the short-term effects of hard and soft splints of different thicknesses on maximum bite force (MBF) and sleep quality (SQ) in participants with sleep bruxism (SB). METHODS One-hundred-fifteen patients were randomly allocated to five groups: Groups H2(Hard splint-2 mm), H3(Hard splint-3 mm), S2(Soft splint-2 mm), S3(Soft splint-3 mm), and C (control). Outcomes were MBF (assessed with a digital gnathodynamometer) and SQ (assessed with the Pittsburgh Sleep Quality Index). Measurements were performed at T0 (before the splints), T1 (1-month follow-up), and T2 (2-months follow-up). Data were analyzed using one-way analysis of variance(ANOVA), Tukey's HSD, and chi-square tests (alpha = 0.05). RESULTS At T1, the highest MBF values were observed in group H3 (658.01 ± 22.6 N), while the lowest in group S2 (585.45 ± 8.68 N). For T2, the highest values were obtained in H3 group (676.85 ± 21.9 N), and the lowest in group S2 (565.65 ± 10.9 N) (p < 0.05).For SQ, groups S2 and S3 revealed the lowest PSQI values at T1 (9.1; 9.6) and T2 (9; 9.5) (p < 0.001). CONCLUSIONS The short-term use of both 2 and 3-mm thick soft splints resulted in a decrease in MBF. Improvement in SQ in patients using soft splints was observed in the 1st month and was maintained in the 2nd month. CLINICAL RELEVANCE This study provides insights on short-term clinical effects as regards to increased sleep quality and regulated maximum bite force as a function of splint material type and the thickness of the splint.
Collapse
Affiliation(s)
- Merve Benli
- Department of Oral Biology, School of Dental Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey.
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center for Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
- Clinic for Chewing Function Disturbances, Center for Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland
| |
Collapse
|
5
|
Lei Q, Lin D, Liu Y, Lin K, Huang W, Wu D. Neuromuscular and occlusion analysis to evaluate the efficacy of three splints on patients with bruxism. BMC Oral Health 2023; 23:325. [PMID: 37231466 DOI: 10.1186/s12903-023-03044-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 05/14/2023] [Indexed: 05/27/2023] Open
Abstract
OBJECTIVE Occlusal splints are always applied on individuals with bruxism to reduce tooth wear and relieve orofacial symptoms such as myofascial pain. The stomatognathic system is mainly composed of tooth, occlusion, masticatory muscles, and temporomandibular joint. The occlusion and masticatory muscles function are regarded as the important parameters for evaluating the stomatognathic system state objectively. However, the effects of occlusal splints on individuals with bruxism is rarely elucidated from accurate neuromuscular analysis and occlusion evaluation. The aim of the present study was to estimate the effects of three different splints (two clinically common full coverage occlusal splint and an modified anterior splint) on subjects with bruxism using K7-J5 neuromuscular analysis system and Dental Prescale II (DP2) to evaluate occlusion. METHODS Sixteen subjects claimed to be suffering from nocturnal bruxism,with complete dentition and stable occlusal relationship, were selected for study.The intermaxillary space and the baselines of EMG-activity of the anterior temporalis and masseter were recorded for all the subjects. The participants was treated with three different splints, and outcomes were estimated by comfort index, occlusion and surface electromyography of anterior temporalis and masseter. RESULTS At teeth clenched position, EMG data were significantly lower in the participants with use of modified anterior splint than with hard, soft occlusal splint or without splint (p < 0.05). The maximum bite force and bite area occur in subjects without use of splint, while the minimal occur in subjects with use of modified anterior splint. Intermaxillary space increased and masticatory muscles presented significant reduction of EMG data at rest position as a result of J5 (p < 0.05). CONCLUSION Modified anterior splint seems to be more comfortable and effective in reducing occlusion force and electromyographic activity of anterior temporalis and masseter for subjects with bruxism.
Collapse
Affiliation(s)
- Qun Lei
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China.
| | - Dong Lin
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Yuyu Liu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Kaijin Lin
- Fujian Medical University, Fuzhou, China
| | - Wenxiu Huang
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Dong Wu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| |
Collapse
|
6
|
Effect of 3D Printer Type and Use of Protection Gas during Post-Curing on Some Physical Properties of Soft Occlusal Splint Material. Polymers (Basel) 2022; 14:polym14214618. [PMID: 36365611 PMCID: PMC9658356 DOI: 10.3390/polym14214618] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Revised: 10/25/2022] [Accepted: 10/28/2022] [Indexed: 11/06/2022] Open
Abstract
Despite the fact that three-dimensional (3D) printing is frequently used in the manufacturing of occlusal splints, the effects of the 3D printer type and post-curing methods are still unclear. The aim of this study was to investigate the effect of the printer type (digital light processing: DLP; and liquid crystal display: LCD) as well as the post-curing method with two different atmospheric conditions (air and nitrogen gas (N2)) on the mechanical and surface properties of 3D-printed soft-type occlusal splint material. The evaluated properties were flexural strength, flexural modulus, Vickers hardness (VHN), fracture toughness, degree of double bond conversion (DC%), water sorption, water solubility, and 3D microlayer structure. The printer type significantly affected all the evaluated properties. Flexural strength, flexural modulus, and fracture toughness were significantly higher when specimens were printed by a DLP printer, while VHN and DC% were significantly higher, and a smoother surface was noticeably obtained when printed by an LCD printer. The post-curing at an N2 atmosphere significantly enhanced all of the evaluated properties except water sorption, 3D microlayer structure, and fracture toughness. The current results suggested that the printer type and the post-curing methods would have an impact on the mechanical and surface properties of the evaluated material.
Collapse
|
7
|
Ferrillo M, Nucci L, Giudice A, Calafiore D, Marotta N, Minervini G, d'Apuzzo F, Ammendolia A, Perillo L, de Sire A. Efficacy of conservative approaches on pain relief in patients with temporomandibular joint disorders: a systematic review with network meta-analysis. Cranio 2022:1-17. [PMID: 36148997 DOI: 10.1080/08869634.2022.2126079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
OBJECTIVE The aim of this systematic review with meta-analysis was to evaluate the efficacy of conservative interventions in pain relief in patients with intracapsular temporomandibular disorders (TMD). METHODS PubMed, Scopus, and Web of Science were systematically searched until January 1st, 2022 to identify randomized controlled trials (RCTs) presenting patients with diagnosis of intracapsular TMD according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD), conservative approaches as interventions, and pain intensity as outcome. RESULTS Out of 3372 papers, 13 RCTs were included, with 844 study participants. Most of them (n = 7) investigated the efficacy of splint appliance. Meta-analysis revealed that rehabilitative interventions had a significant overall effect size of 0.75 [0.17, 1.34], reporting splint appliance and laser therapy as significantly effective treatments. CONCLUSION Findings of this systematic review with network meta-analysis suggested that conservative approaches might be effective in pain relief of intracapsular TMD patients.
Collapse
Affiliation(s)
- Martina Ferrillo
- Dentistry Unit, Department of Health Sciences, University of Catanzaro "Magna Graecia", Catanzaro, Italy
| | - Ludovica Nucci
- Dentistry Unit, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Amerigo Giudice
- Dentistry Unit, Department of Health Sciences, University of Catanzaro "Magna Graecia", Catanzaro, Italy
| | - Dario Calafiore
- Physical Medicine and Rehabilitation Unit, Department of Neurosciences, ASST Carlo Poma, Mantova, Italy
| | - Nicola Marotta
- Physical Medicine and Rehabilitation Unit, Department of Medical and Surgical Sciences, University of Catanzaro "Magna Graecia", Catanzaro, Italy
| | - Giuseppe Minervini
- Dentistry Unit, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Fabrizia d'Apuzzo
- Dentistry Unit, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Antonio Ammendolia
- Physical Medicine and Rehabilitation Unit, Department of Medical and Surgical Sciences, University of Catanzaro "Magna Graecia", Catanzaro, Italy
| | - Letizia Perillo
- Dentistry Unit, Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy
| | - Alessandro de Sire
- Physical Medicine and Rehabilitation Unit, Department of Medical and Surgical Sciences, University of Catanzaro "Magna Graecia", Catanzaro, Italy
| |
Collapse
|
8
|
Biomechanical Behavior Evaluation of a Novel Hybrid Occlusal Splint-Mouthguard for Contact Sports: 3D-FEA. Dent J (Basel) 2021; 10:dj10010003. [PMID: 35049601 PMCID: PMC8774877 DOI: 10.3390/dj10010003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/14/2021] [Accepted: 12/14/2021] [Indexed: 12/23/2022] Open
Abstract
Background: Orofacial injuries are common occurrences during contact sports activities. However, there is an absence of data regarding the performance of hybrid occlusal splint mouthguards (HMG), especially during compressive loading. This study amid to evaluate the biomechanical effects of wearing a conventional custom mouthguard (MG) or the HMG on the teeth, bone, and the device itself. Methods: To evaluate the total deformation and stress concentration, a skull model was selected and duplicated to receive two different designs of mouthguard device: one model received a MG with 4-mm thickness and the other received a novel HMG with the same thickness. Both models were subdivided into finite elements. The frictionless contacts were used, and a nonlinear analysis was performed simulating the compressive loading in occlusion. Results: The results were presented in von-Mises stress maps (MPa) and total deformation (mm). A higher stress concentration in teeth was observed for the model with the conventional MG, while the HMG design displayed a promising mechanical response with lower stress magnitude. The HMG design displayed a higher magnitude of stress on its occlusal portion (7.05 MPa) than the MG design (6.19 MPa). Conclusion: The hybrid mouthguard (HMG) reduced (1) jaw displacement during chewing and (2) the generated stresses in maxillary and mandibular teeth.
Collapse
|