1
|
Shu J, Zheng N, Teng H, Tsai TY, Liu Z. In vivo biomechanical dynamic simulation of a healthy knee during the single-leg lunge and its experiment validation. Med Eng Phys 2024; 129:104183. [PMID: 38906571 DOI: 10.1016/j.medengphy.2024.104183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 04/28/2024] [Accepted: 05/17/2024] [Indexed: 06/23/2024]
Abstract
Biomechanical modeling of the knee during motion is a pivotal component in disease treatment, implant designs, and rehabilitation strategies. Historically, dynamic simulations of the knee have been scant. This study uniquely integrates a dual fluoroscopic imaging system (DFIS) to investigate the in vivo dynamic behavior of the meniscus during functional activities using a finite element (FE) model. The model was subsequently validated through experiments. Motion capture of a single-leg lunge was executed by DFIS. The motion model was reconstructed using 2D-to-3D registration in conjunction with computed tomography (CT) scans. Both CT and magnetic resonance imaging (MRI) data facilitated the development of the knee FE model. In vivo knee displacements and rotations were utilized as driving conditions for the FE model. Moreover, a 3D-printed model, accompanied with digital imaging correlation (DIC), was used to evaluate the accuracy of the FE model. To a better inner view of knees during the DIC analysis, tibia and femur were crafted by transparent resin. The availability of the FE model was guaranteed by the similar strain distribution of the DIC and FE simulation. Subsequent modeling revealed that the compressive stress distribution between the medial and lateral menisci was balanced in the standing posture. As the flexion angle increased, the medial meniscus bore the primary compressive load, with peak stresses occurring between 60 and 80° of flexion. The simulation of a healthy knee provides a critical theoretical foundation for addressing knee pathologies and advancing prosthetic designs.
Collapse
Affiliation(s)
- Jingheng Shu
- Key Lab for Biomechanical Engineering of Sichuan Province, Sichuan University, Chengdu, China; Yibin Institute of Industrial Technology/Sichuan University Yibin Park, Yibin, China
| | - Nan Zheng
- School of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China; Engineering Research Center for Digital Medicine of the Ministry of Education, Shanghai, China
| | - Haidong Teng
- Key Lab for Biomechanical Engineering of Sichuan Province, Sichuan University, Chengdu, China; Yibin Institute of Industrial Technology/Sichuan University Yibin Park, Yibin, China
| | - Tsung-Yuan Tsai
- School of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China; Engineering Research Center for Digital Medicine of the Ministry of Education, Shanghai, China.
| | - Zhan Liu
- Key Lab for Biomechanical Engineering of Sichuan Province, Sichuan University, Chengdu, China; Yibin Institute of Industrial Technology/Sichuan University Yibin Park, Yibin, China.
| |
Collapse
|
2
|
Chen L, Wang M, Wu Z, Sun J, Li J, Chen C, Ye C. Advancements in health informatics: finite element insights into medial open-wedge high tibial osteotomy and lateral meniscal tears. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2024; 21:5394-5410. [PMID: 38872540 DOI: 10.3934/mbe.2024237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2024]
Abstract
Knee medial compartment osteoarthritis is effectively treated by a medial open-wedge high tibial osteotomy (MOWHTO). The feasibility and safety of MOWHTO for mild lateral meniscal tears are unknown. This study examined the feasibility and safety of knee joint weight-bearing line ratio (WBLr) adjustment during MOWHTO with lateral meniscal injuries. We used a healthy adult male's lower extremities computed tomography scans and knee joint magnetic resonance imaging images to create a normal fine element (FE) model. Based on this model, we generated nine FE models for the MOWHTO operation (WBLr: 40-80%) and 15 models for various lateral meniscal injuries. A compressive load of 650N was applied to all cases to calculate the von Mises stress (VMS), and the intact lateral meniscus' maximal VMS at 77.5% WBLr was accepted as the corrective upper limit stress. Our experimental results show that mild lateral meniscal tears can withstand MOWHTO, while severe tears cannot. Our findings expand the use of MOWHTO and provide a theoretical direction for practical decisions in patients with lateral meniscal injuries.
Collapse
Affiliation(s)
- Lin Chen
- Department of Orthopedics, The Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
- Center for Tissue Engineering and Stem Cells, Guizhou Medical University, Guiyang 550004, China
- Department of Orthopedics, People's Hospital of Xingyi City, Xingyi 562400, China
| | - Mingjun Wang
- Department of Orthopedics, People's Hospital of Xingyi City, Xingyi 562400, China
| | - Zhanyu Wu
- Department of Orthopedics, The Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
- Center for Tissue Engineering and Stem Cells, Guizhou Medical University, Guiyang 550004, China
| | - Jinbo Sun
- Department of Orthopedics, People's Hospital of Xingyi City, Xingyi 562400, China
| | - Jianglong Li
- Department of Orthopedics, People's Hospital of Xingyi City, Xingyi 562400, China
| | - Chun Chen
- Department of Orthopedics, People's Hospital of Xingyi City, Xingyi 562400, China
| | - Chuan Ye
- Department of Orthopedics, The Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
- Center for Tissue Engineering and Stem Cells, Guizhou Medical University, Guiyang 550004, China
| |
Collapse
|
3
|
Simkheada T, Orozco GA, Korhonen RK, Tanska P, Mononen ME. Comparison of constitutive models for meniscus and their effect on the knee joint biomechanics during gait. Comput Methods Biomech Biomed Engin 2023; 26:2008-2021. [PMID: 36645841 DOI: 10.1080/10255842.2022.2163587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 11/25/2022] [Accepted: 12/20/2022] [Indexed: 01/18/2023]
Abstract
Mechanical behavior of meniscus can be modeled using constitutive material models of varying complexity, such as isotropic elastic or fibril reinforced poroelastic (FRPE). However, the FRPE material is complex to implement, computationally demanding in 3D geometries, and simulation is time-consuming. Hence, we aimed to quantify the most suitable and efficient constitutive model of meniscus for simulation of cartilage responses in the knee joint during walking. We showed that simpler constitutive material models can reproduce similar cartilage responses to a knee model with the FRPE meniscus, but only knee models that consider orthotropic elastic meniscus can also reproduce meniscus responses adequately.
Collapse
Affiliation(s)
- Tulashi Simkheada
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Gustavo A Orozco
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
- Department of Biomedical Engineering, Lund University, Lund, Sweden
| | - Rami K Korhonen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Petri Tanska
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - Mika E Mononen
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| |
Collapse
|
4
|
Medial meniscus posterior root tears and partial meniscectomy significantly increase stress in the knee joint during dynamic gait. Knee Surg Sports Traumatol Arthrosc 2022; 31:2289-2298. [PMID: 36534149 DOI: 10.1007/s00167-022-07285-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 12/09/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE As a simple and invasive treatment, arthroscopic medial meniscal posterior horn resections (MMPHRs) can relieve the obstructive symptoms of medial meniscus posterior root tears (MMPRTs) but with the risk of aggravating biomechanical changes of the joint. The aim of this study was to analyze dynamic simulation of the knee joint after medial meniscus posterior root tear and posterior horn resection. METHODS This study established static and dynamic models of MMPRTs and MMPHRs on the basis of the intact medial meniscus model (IMM). In the finite element analysis, the three models were subjected to 1000 N axial static load and the human walking gait load defined by the ISO14243-1 standard to evaluate the influence of MMPRTs and MMPHRs on knee joint mechanics during static standing and dynamic walking. RESULTS In the static state, the load ratio of the medial and lateral compartments remained nearly constant (2:1), while in the dynamic state, the load ratio varied with the gait cycle. After MMPHRs, at 30% of the gait cycle, compared with the MMPRTs condition, the maximum von Mises stress of the lateral meniscus (LM) and the lateral tibial cartilage (LTC) were increased by 166.0% and 50.0%, respectively, while they changed by less than 5% during static analysis. The maximum von Mises stress of the medial meniscus (MM) decreased by 55.7%, and that of the medial femoral cartilage (MFC) increased by 53.5%. CONCLUSION After MMPHRs, compared with MMPRTs, there was no significant stress increase in articular cartilage in static analysis, but there was a stress increase and concentration in both medial and lateral compartments in dynamic analysis, which may aggravate joint degeneration. Therefore, in clinical treatments, restoring the natural structure of MMPRTs is first recommended, especially for physically active patients.
Collapse
|
5
|
Characterization of Synovial Cytokine Patterns in Bucket-Handle and Posterior Horn Meniscal Tears. Mediators Inflamm 2020; 2020:5071934. [PMID: 33144846 PMCID: PMC7599409 DOI: 10.1155/2020/5071934] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 09/23/2020] [Accepted: 10/15/2020] [Indexed: 01/30/2023] Open
Abstract
The specific etiology of meniscal tears, including the mechanism of lesion, location, and orientation, is considered for its contribution to subsequent joint cytokine responsiveness, healing outcomes, and by extension, appropriate lesion-specific surgical remediation. Meniscal repair is desirable to reduce the probability of development of posttraumatic osteoarthritis (PTOA) which is strongly influenced by the coordinate generation of pro- and anti-inflammatory cytokines by the injured cartilage. We now present biochemical data on variation in cytokine levels arising from two particular meniscal tears: bucket-handle (BH) and posterior horn (PH) isolated meniscal tears. We selected these two groups due to the different clinical presentations. We measured the concentrations of TNF-α, IL-1β, IL-6, IL-8, and IL-10 in knee synovial fluid of 45 patients with isolated meniscal lesions (BH tear, n = 12; PH tear, n = 33). TNF-α levels were significantly (p < 0.05) greater in the BH group compared with the PH group, whereas IL-1β levels were significantly greater (p < 0.05) in the PH group compared with the BH group. Both BH and PH groups were consistent in presenting a positive correlation between concentrations of IL-6 and IL-1β. A fundamental difference in IL-10 responsiveness between the two groups was noted; specifically, levels of IL-10 were positively correlated with IL-6 in the BH group, whereas in the PH group, levels of IL-10 were positively correlated with IL-1β. Collectively, our data suggest a possible influence of the meniscal tear pattern to the articular cytokine responsiveness. This differential expression of inflammatory cytokines may influence the risk of developing PTOA in the long term.
Collapse
|
6
|
Xu J, Wang K, Gao M, Tu Z, Zhang S, Tan J. Biomechanical performance design of joint prosthesis for medical rehabilitation via generative structure optimization. Comput Methods Biomech Biomed Engin 2020; 23:1163-1179. [PMID: 32660275 DOI: 10.1080/10255842.2020.1789970] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
This paper proposes a biomechanical performance design method of joint prosthesis for medical rehabilitation via Generative Structure Optimization (GSO). Firstly, the 3D reconstruction of manifold structure involving hard bone and cartilage is sequentially and progressively implemented from heterogeneous medical images such as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) via iteration. On the basis of reconstructed mesh structure, the finite element method (FEM) is hereby employed to verify the structure by evaluating the mechanical force distribution. The biomechanical performance design model for 3 D printing (3DP) is then built using multi-objective optimization (MOO) by considering adaptive layer thickness, infill patterns and infill trajectories, etc. The GSO outlets a generative data-driven system which covers various stages such as personalized CT, subsequent 3 D reconstruction, further finite element analysis (FEA) and even structural parameter optimization. The physical experiment of Additive manufacturing (AM) proves that, the relative density, surface topography and wear-resisting performance of joint prosthesis can be improved by GSO which helps to improve biomechanical performance, including kinematics and dynamics. The proposed method may arouse the huge attention in the prosthesis applications to promote patients' high-end customization well-being.
Collapse
Affiliation(s)
- Jinghua Xu
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China.,Key Lab of Advanced Manufacturing Technology of Zhejiang Province, Zhejiang University, Hangzhou, China.,School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Kang Wang
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Mingyu Gao
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Zhengxin Tu
- School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Shuyou Zhang
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China.,Key Lab of Advanced Manufacturing Technology of Zhejiang Province, Zhejiang University, Hangzhou, China.,School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| | - Jianrong Tan
- State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou, China.,Key Lab of Advanced Manufacturing Technology of Zhejiang Province, Zhejiang University, Hangzhou, China.,School of Mechanical Engineering, Zhejiang University, Hangzhou, China
| |
Collapse
|