1
|
Nebel S, Vardon D, Dreyfus M, Pizzoferrato AC. 2D-transperineal ultrasound in delivery room: Contribution in assessing labor progress, predicting outcome of labor and recognizing obstetric anal sphincter injuries (OASIS). A systematic review. J Gynecol Obstet Hum Reprod 2025; 54:102910. [PMID: 39814335 DOI: 10.1016/j.jogoh.2025.102910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2024] [Revised: 12/17/2024] [Accepted: 01/12/2025] [Indexed: 01/18/2025]
Abstract
AIMS Ultrasound is used in the delivery room to assess fetal head position, engagement during labor, and anal sphincter injuries in the immediate postpartum period. The transperineal approach allows for direct visualization of the structures of interest without altering anatomical landmarks. Various ultrasound measurements during labor have been described in the literature, and their use varies widely across maternity units. Our objective was to conduct a systematic review of the literature on relevant ultrasound parameters for the management of labor and delivery. MATERIAL AND METHODS We reviewed articles indexed in MEDLINE from 1990 to 2022, selecting those that evaluated transperineal ultrasound during labor for term singleton fetuses in cephalic presentation. RESULTS We identified 124 articles out of 394 references, including 4 randomized controlled trials, 108 prospective studies, 6 cross-sectional studies, and 6 retrospective studies. The Angle of Progression (AOP) is better documented and appears more reliable than the Head-Perineum Distance (HPD) for diagnosing engagement, monitoring labor, and predicting its outcome. The HPD is easier to perform but shows inconsistencies in the literature. The Head Progression Distance (HPrD) shows good performance but requires further studies before routine use, as does Head-Symphysis Distance (HSD). Recent studies show a growing interest in ultrasound biofeedback of fetal head progression to improve pushing efforts as well as screening for Obstetrical Anal Sphincter Injuries (OASIS). CONCLUSIONS Transperineal ultrasound is a minimally invasive technique that can be used routinely in the delivery room. It can aid in monitoring labor, predicting the mode of delivery, and may serve as valuable biofeedback to optimize pushing during expulsion.
Collapse
Affiliation(s)
- Siegfried Nebel
- Department of Obstetrics and Gynecology, Caen University Hospital, Pôle Femme-Enfant, Avenue de la Côte de Nacre, Caen CEDEX 14033, France.
| | - Delphine Vardon
- Department of Obstetrics and Gynecology, Caen University Hospital, Pôle Femme-Enfant, Avenue de la Côte de Nacre, Caen CEDEX 14033, France
| | - Michel Dreyfus
- Department of Obstetrics and Gynecology, Caen University Hospital, Pôle Femme-Enfant, Avenue de la Côte de Nacre, Caen CEDEX 14033, France
| | - Anne-Cécile Pizzoferrato
- Department of Obstetrics and Gynecology, Poitiers University Hospital, 2 Rue de la Milétrie, Poitiers 86000, France; INSERM, CIC 1402, Poitiers University Hospital; Poitiers University, Poitiers, France
| |
Collapse
|
2
|
Lan L, Luo D, Lian J, She L, Zhang B, Zhong H, Wang H, Wu H. Chromosomal Abnormalities Detected by Chromosomal Microarray Analysis and Karyotype in Fetuses with Ultrasound Abnormalities. Int J Gen Med 2024; 17:4645-4658. [PMID: 39429961 PMCID: PMC11488349 DOI: 10.2147/ijgm.s483290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Accepted: 10/01/2024] [Indexed: 10/22/2024] Open
Abstract
Objective Chromosomal microarray analysis (CMA) is a first-line test to assess the genetic etiology of fetal ultrasound abnormalities. The aim of this study was to evaluate the effectiveness of CMA in detecting chromosomal abnormalities in fetuses with ultrasound abnormalities, including structural abnormalities and non-structural abnormalities. Methods A retrospective study was conducted on 368 fetuses with abnormal ultrasound who received interventional prenatal diagnosis at Meizhou People's Hospital from October 2022 to December 2023. Samples of villi, amniotic fluid, and umbilical cord blood were collected according to different gestational weeks, and karyotype and CMA analyses were performed. The detection rate of chromosomal abnormalities in different ultrasonic abnormalities was analyzed. Results There were 368 fetuses with abnormal ultrasound, including 114 (31.0%) with structural abnormalities, 225 (61.1%) with non-structural abnormalities, and 29 (7.9%) with structural combined with non-structural abnormalities. The detection rate of aneuploidy and pathogenic (P)/likely pathogenic (LP) copy number variations (CNVs) of CMA in fetuses with structural abnormalities was 5.26% (6/114), the detection rate of karyotype was 2.63% (3/114), and the additional diagnosis rate of CMA was 2.63%. In the fetuses with ultrasonic non-structural abnormalities, the detection rate of karyotype was 6.22% (14/225), the detection rate of aneuploidy and P/LP CNVs in fetuses with ultrasonic structural abnormalities was 9.33% (21/225), and the additional diagnosis rate of CMA was 3.11%. There was no significant difference in chromosome abnormality detection rate of CMA among structural abnormality, non-structural abnormality, and structural abnormality combined with non-structural abnormality groups (5.3%, 9.3%, and 13.8%, p = 0.241), also among multiple ultrasonic abnormality and single ultrasonic abnormality groups (14.8%, and 7.3%, p = 0.105). Conclusion CMA can significantly improve the detection rate of genetic abnormalities in prenatal diagnosis of ultrasonic abnormal fetuses compared with karyotype analysis. CMA is a more effective tool than karyotyping alone in detecting chromosomal abnormalities in fetuses with ultrasound abnormalities.
Collapse
Affiliation(s)
- Liubing Lan
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
- Department of Obstetrics, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Dandan Luo
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
- Department of Obstetrics, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Jianwen Lian
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Lingna She
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
- Department of Ultrasound, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Bosen Zhang
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
- Department of Ultrasound, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Hua Zhong
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Huaxian Wang
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| | - Heming Wu
- Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou, People’s Republic of China
| |
Collapse
|
3
|
Lee NMW, Lau SL, Yeung YK, Chiu CPH, Liu F, Lau YY, Fidalgo AM, Cuerva MJ, Aquise A, Nguyen-Hoang L, Gil MM, Poon LC. Implementation of sonopartogram: multicenter feasibility study. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2024; 64:214-221. [PMID: 38456522 DOI: 10.1002/uog.27634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 02/04/2024] [Accepted: 02/13/2024] [Indexed: 03/09/2024]
Abstract
OBJECTIVES Well-established clinical practice for assessing progress in labor involves routine abdominal palpation and vaginal examination (VE). However, VE is subjective, poorly reproducible and painful for most women. In this study, our aim was to evaluate the feasibility of systematically integrating transabdominal and transperineal ultrasound assessment of fetal position, parasagittal angle of progression (psAOP), head-perineum distance (HPD) and sonographic cervical dilatation (SCD) to monitor the progress of labor in women undergoing induction of labor (IOL). We also aimed to determine if ultrasound can reduce women's pain during such examinations. METHODS Women were recruited as they presented for IOL in three maternity units. Ultrasound assessments were performed in 100 women between 37 + 0 and 41 + 6 weeks' gestation. A baseline combined transabdominal and transperineal scan was performed, including assessment of fetal biometry, umbilical artery and fetal middle cerebral artery Doppler, amniotic fluid index, fetal spine and occiput positions, psAOP, HPD, SCD and cervical length. Intrapartum scans were performed instead of VE, unless there was a clinical indication to perform a VE, according to protocol. Participants were asked to indicate their level of pain by verbally giving a pain score between 0 and 10 (with 0 representing no pain) during assessment. Repeated measures data were analyzed using mixed-effect models to identify significant factors that affected the relationship between psAOP, HPD, SCD and mode of delivery. RESULTS A total of 100 women were included in the study. Of these, 20% delivered by Cesarean section, 65% vaginally and 15% by instrumental delivery. There were no adverse fetal or maternal outcomes. A total of 223 intrapartum ultrasound scans were performed in 87 participants (13 women delivered before intrapartum ultrasound was performed), with a median of two scans per participant (interquartile range (IQR), 1-3). Of these, 76 women underwent a total of 151 VEs with a median of one VE per participant (IQR, 0-2), with no significant difference between vaginal- or Cesarean-delivery groups. After excluding those with epidural anesthesia during examination, the median pain score for intrapartum scans was 0 (IQR, 0-1) and for VE it was 3 (IQR, 0-6). Cesarean delivery was significantly associated with a slower rate of change in psAOP, HPD and SCD. CONCLUSIONS Comprehensive transabdominal and transperineal ultrasound assessment can be used to assess progress in labor and can reduce the level of pain experienced during examination. Ultrasound assessment may be able to replace some transabdominal and vaginal examinations during labor. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- N M W Lee
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - S L Lau
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Y K Yeung
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - C P H Chiu
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - F Liu
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Y Y Lau
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - A M Fidalgo
- Obstetrics and Gynecology Department, Hospital Universitario de Torrejón, Torrejón de Ardoz, Madrid, Spain
- School of Medicine, Universidad Francisco de Vitoria, Madrid, Spain
| | - M J Cuerva
- Department of Obstetrics, Hospital Universitario La Paz, Madrid, Spain
- School of Medicine, Universidad Autónoma de Madrid, Madrid, Spain
| | - A Aquise
- Obstetrics and Gynecology Department, Hospital Universitario de Torrejón, Torrejón de Ardoz, Madrid, Spain
| | - L Nguyen-Hoang
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - M M Gil
- Obstetrics and Gynecology Department, Hospital Universitario de Torrejón, Torrejón de Ardoz, Madrid, Spain
- School of Medicine, Universidad Francisco de Vitoria, Madrid, Spain
| | - L C Poon
- Department of Obstetrics and Gynecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| |
Collapse
|
4
|
Exner F, Caspers R, Kennes LN, Wittenborn J, Kupec T, Stickeler E, Najjari L. Digital Examination vs. 4D Transperineal Ultrasound-Do They Compare in Labour Management? A Pilot Study. Diagnostics (Basel) 2024; 14:293. [PMID: 38337809 PMCID: PMC10854967 DOI: 10.3390/diagnostics14030293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Revised: 01/11/2024] [Accepted: 01/25/2024] [Indexed: 02/12/2024] Open
Abstract
The aim was to compare transperineal ultrasound (TPU) with parameters of the Bishop Score during the first stage of labour and evaluate how TPU can contribute towards improving labour management. Digital examination (DE) and TPU were performed on 42 women presenting at the labour ward with regular contractions. TPU measurements included the head-symphysis distance, angle of progression, diameter of the cervical wall, cervical dilation (CD) and cervical length (CL). To examine if TPU can monitor labour progress, correlations of TPU parameters were calculated. Agreement of DE and TPU was examined for CL and CD measurements and for two groups divided into latent (CD < 5 cm) and active stages of labour (CD ≥ 5 cm). TPU parameters indicated a moderate negative correlation of CD and CL (Pearson: r = -0.667; Spearman = -0.611). The other parameters showed a weak to moderate correlation. DE and TPU measurements for CD showed better agreement during the latent stage than during the active stage. The results of the present study add to the growing evidence that TPU may contribute towards an improved labour management, suggesting a combined approach of TPU and DE to monitor the latent first stage of labour and using only DE during the active stage of labour.
Collapse
Affiliation(s)
- Friederike Exner
- Department of Gynaecology and Obstetrics, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Rebecca Caspers
- Department of Gynaecology and Obstetrics, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Lieven Nils Kennes
- Department of Economics and Business Administration, Hochschule Stralsund, 18435 Stralsund, Germany
| | - Julia Wittenborn
- Department of Gynaecology and Obstetrics, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Tomás Kupec
- Department of Gynaecology and Obstetrics, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Elmar Stickeler
- Department of Gynaecology and Obstetrics, University Hospital RWTH Aachen, 52074 Aachen, Germany
| | - Laila Najjari
- Department of Gynaecology and Obstetrics, University Hospital RWTH Aachen, 52074 Aachen, Germany
| |
Collapse
|
5
|
Connell P, Turrentine M, Antoniewicz L. Use of a pocket-device point-of-care ultrasound to assess cervical dilation in labor: correlation and patient experience. J Perinat Med 2023; 51:962-964. [PMID: 36607968 DOI: 10.1515/jpm-2022-0518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Accepted: 11/21/2022] [Indexed: 01/07/2023]
Abstract
OBJECTIVES To estimate the correlation of cervical dilation between pocket-device point-of-care transperineal ultrasound (TPUS) and digital cervical examination (DCE). METHODS Laboring pregnant individuals ≥37 weeks of gestation presenting were prospectively evaluated for cervical dilation with a handheld pocket-sized ultrasound (Butterfly iQ+®) applied to the perineum, with a blinded DCE directly following. Subjects completed a survey to rate pain and for any preference from the examinations. To detect a moderate correlation (r=0.5) between TPUS and DCE, with an alpha of 0.05 and power of 80%, a sample size of 30 examinations were needed. RESULTS From April 2022 to July 2022, 30 pregnant individuals were assessed. The median cervical dilation by TPUS vs. DCE was 5.1 and 5 cm, respectively, with a Pearson's correlation coefficient, r=0.86 (95% CI 0.72 to 0.93), p<0.001. Transperineal ultrasound had a significantly less pain score than DCE, median pain score 0 vs. 2 for TPUS and DCE respectively, p<0.001. All individuals preferred the TPUS over the DCE. CONCLUSIONS Measurement of cervical dilation using a pocket-device point-of-care TPUS has a strong positive correlation with DCE and offers a non-invasive, convenient alternative to traditional digital exams in term, laboring patients.
Collapse
Affiliation(s)
- Phillip Connell
- Department of Obstetrics & Gynecology, Baylor College of Medicine, Houston, TX, USA
| | - Mark Turrentine
- Department of Obstetrics & Gynecology, Baylor College of Medicine, Houston, TX, USA
| | - Leah Antoniewicz
- Department of Obstetrics & Gynecology, Baylor College of Medicine, Houston, TX, USA
| |
Collapse
|
6
|
Mlodawski J, Mlodawska M, Plusajska J, Detka K, Bialek K, Swiercz G. Repeatability and Reproducibility of Potential Ultrasonographic Bishop Score Parameters. J Clin Med 2023; 12:4492. [PMID: 37445532 DOI: 10.3390/jcm12134492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2023] [Revised: 07/01/2023] [Accepted: 07/03/2023] [Indexed: 07/15/2023] Open
Abstract
Determination of the Bishop score (BS) is a traditional method of assessing the cervix in obstetrics and gynecology. This examination is characterized by subjectivity of assessment and low repeatability. In scientific studies intended to evaluate the results of the procedure based on the initial assessment, it is necessary to find an objective scale based on ultrasonography. We selected five ultrasound parameters, measured with a transvaginal transducer, that are equivalent to the individual BS axes (dilatation assessed in three-dimensional ultrasound (DL), angle of progression (AoP), vagino-cervical angle (VCA), strain elastography using the E-Cervix module, and cervical length (CL)). All selected parameters were characterized by good to excellent repeatability (intraclass correlation coefficient (ICC) = 0.878-0.994) and reproducibility (ICC = 0.826-0.996). Each of the selected parameters significantly correlated with its corresponding BS axis. The highest value of the correlation coefficient was achieved with CL (-0.75) and DL (0.71). Other parameters were characterized by an average to high correlation (AoP and station = 0.69, hardness ratio and consistency = -0.33, position and VCA = -0.38). The best correlation with the sum of the BS points was exhibited by AoP (0.52) and CL (-0.61). The selected ultrasound parameters analogous to the BS axes were characterized by high repeatability and significant correlation with the axes of the original clinical BS. Further research into the predictive properties of a multivariate model based on these parameters is needed.
Collapse
Affiliation(s)
- Jakub Mlodawski
- Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland
- Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland
| | - Marta Mlodawska
- Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland
| | - Justyna Plusajska
- Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland
- Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland
| | - Karolina Detka
- Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland
| | - Katarzyna Bialek
- Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland
- Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland
| | - Grzegorz Swiercz
- Collegium Medicum, Jan Kochanowski University, 25-369 Kielce, Poland
- Clinic of Obstetrics and Gynaecology, Provincial Combined Hospital in Kielce, 25-736 Kielce, Poland
| |
Collapse
|
7
|
Usman S, Hanidu A, Kovalenko M, Hassan WA, Lees C. The sonopartogram. Am J Obstet Gynecol 2023; 228:S997-S1016. [PMID: 37164504 DOI: 10.1016/j.ajog.2022.06.027] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 06/15/2022] [Accepted: 06/16/2022] [Indexed: 03/17/2023]
Abstract
The assessment of labor progress from digital vaginal examination has remained largely unchanged for at least a century, despite the current major advances in maternal and perinatal care. Although inconsistently reproducible, the findings from digital vaginal examination are customarily plotted manually on a partogram, which is composed of a graphical representation of labor, together with maternal and fetal observations. The partogram has been developed to aid recognition of failure to labor progress and guide management-specific obstetrical intervention. In the last decade, the use of ultrasound in the delivery room has increased with the advent of more powerful, portable ultrasound machines that have become more readily available for use. Although ultrasound in intrapartum practice is predominantly used for acute management, an ultrasound-based partogram, a sonopartogram, might represent an objective tool for the graphical representation of labor. Demonstrating greater accuracy for fetal head position and more objectivity in the assessment of fetal head station, it could be considered complementary to traditional clinical assessment. The development of the sonopartogram concept would require further undertaking of serial measurements. Advocates of ultrasound will concede that its use has yet to demonstrate a difference in obstetrical and neonatal morbidity in the context of the management of labor and delivery. Taking a step beyond the descriptive graphical representation of labor progress is the question of whether a specific combination of clinical and demographic parameters might be used to inform knowledge of labor outcomes. Intrapartum cesarean deliveries and deliveries assisted by forceps and vacuum are all associated with a heightened risk of maternal and perinatal adverse outcomes. Although these outcomes cannot be precisely predicted, many known risk factors exist. Malposition and high station of the fetal head, short maternal stature, and other factors, such as caput succedaneum, are all implicated in operative delivery; however, the contribution of individual parameters based on clinical and ultrasound assessments has not been quantified. Individualized risk prediction models, including maternal characteristics and ultrasound findings, are increasingly used in women's health-for example, in preeclampsia or trisomy screening. Similarly, intrapartum cesarean delivery models have been developed with good prognostic ability in specifically selected populations. For intrapartum ultrasound to be of prognostic value, robust, externally validated prediction models for labor outcome would inform delivery management and allow shared decision-making with parents.
Collapse
|
8
|
Assessment of labor progress by ultrasound vs manual examination: a randomized controlled trial. Am J Obstet Gynecol MFM 2023; 5:100817. [PMID: 36400420 DOI: 10.1016/j.ajogmf.2022.100817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 11/17/2022]
Abstract
BACKGROUND Assessment of labor progress via digital examination is considered the standard of care in most delivery rooms. However, this method can be stressful, painful, and imprecise, and multiple examinations increase the risk for chorioamnionitis. Intrapartum ultrasound was found to be an objective, noninvasive tool to monitor labor progression. OBJECTIVE This study aimed to investigate whether, among nulliparous women, the use of intrapartum ultrasound can reduce the rate of intrapartum fever by reducing the number of digital examinations. STUDY DESIGN This was a prospective, randomized controlled trial in term nulliparas admitted with prelabor rupture of membranes, induction of labor, or in latent phase of labor with a cervical dilation of <4 cm. Women were randomized into 1 of the following 2 arms: (1) labor progress assessed by ultrasound, avoiding digital examinations as much as possible; and (2) control group in which labor progression was assessed according to the regular protocol. Before the study, all labor ward physicians underwent training in intrapartum ultrasound. RESULTS A total of 90 women were randomized to the ultrasound group and 92 were randomized to the control group. When compared with the control group, the ultrasound group had significantly lower rates of intrapartum fever (11.1% vs 26.1%; P=.01), clinical chorioamnionitis (3.3% vs 16.5%; P>.01), and histologic chorioamnionitis (2.2% vs 9.8%; P=.03). The median number of digital examinations was significantly lower in the ultrasound group (5; interquartile range, 4-6) than in the control group (8; interquartile range, 6-10; P<.01). The median number of digital examinations per hour in the ultrasound group was significantly lower than in the control group (0.2 vs 0.4; P<.01). The induction rates, time from admission to delivery, mode of delivery, Apgar score at 5 minutes, and neonatal intensive care unit admission rates did not differ significantly between the groups. CONCLUSION The use of intrapartum ultrasound lessens the total number of digital examinations needed to be performed during labor and, consequently, the incidence of intrapartum fever and chorioamnionitis are reduced. No adverse effects on labor progression and short-term maternal or neonatal outcomes were noted.
Collapse
|
9
|
Santana EFM, Castello RG, Passos MET, Ribeiro GCF, Araujo Júnior E. How to Reach the Best Ultrasound Performance in the Delivery Room. REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA : REVISTA DA FEDERACAO BRASILEIRA DAS SOCIEDADES DE GINECOLOGIA E OBSTETRICIA 2022; 44:1070-1077. [PMID: 36580951 PMCID: PMC9800070 DOI: 10.1055/s-0042-1759773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Ultrasonography is an instrument that is present in the maternal-fetal assessment throughout pregnancy and with widely documented benefits, but its use in intrapartum is becoming increasingly relevant. From the assessment of labor progression to the assessment of placental disorders, ultrasound can be used to correlate with physiological findings and physical examination, as its benefit in the delivery room cannot yet be proven. There are still few professionals with adequate training for its use in the delivery room and for the correct interpretation of data. Thus, this article aims to present a review of the entire applicability of ultrasound in the delivery room, considering the main stages of labor. There is still limited research in evidence-based medicine of its various possible uses in intrapartum, but it is expected that further studies can bring improvements in the quality of maternal and neonatal health during labor.
Collapse
Affiliation(s)
- Eduardo Félix Martins Santana
- Medical Course, Albert Einstein Medical School, São Paulo, SP, Brazil.,Fetal Medicine Unit, Albert Einstein Hospital, São Paulo, SP, Brazil.
| | | | | | | | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of Sao Paulo, São Paulo, SP, Brazil.,Medical Course, Municipal University of Sao Caetano do Sul, São Paulo, SP, Brazil.,Address for correspondence Edward Araujo Junior, PhD Rua Borges Lagoa, 1341, 04038-034, Vila Clementino, São Paulo, SPBrazil
| |
Collapse
|
10
|
Rizzo G, Ghi T, Henrich W, Tutschek B, Kamel R, Lees CC, Mappa I, Kovalenko M, Lau W, Eggebo T, Achiron R, Sen C. Ultrasound in labor: clinical practice guideline and recommendation by the WAPM-World Association of Perinatal Medicine and the PMF-Perinatal Medicine Foundation. J Perinat Med 2022; 50:1007-1029. [PMID: 35618672 DOI: 10.1515/jpm-2022-0160] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 12/27/2022]
Abstract
This recommendation document follows the mission of the World Association of Perinatal Medicine in collaboration with the Perinatal Medicine Foundation. We aim to bring together groups and individuals throughout the world for standardization to implement the ultrasound evaluation in labor ward and improve the clinical management of labor. Ultrasound in labor can be performed using a transabdominal or a transperineal approach depending upon which parameters are being assessed. During transabdominal imaging, fetal anatomy, presentation, liquor volume, and placental localization can be determined. The transperineal images depict images of the fetal head in which calculations to determine a proposed fetal head station can be made.
Collapse
Affiliation(s)
- Giuseppe Rizzo
- Department of Obstetrics and Gynecology, Università di Roma Tor Vergata, Fondazione Policlinico Tor Vergata, Rome, Italy
| | - Tullio Ghi
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- UOC Ostetricia e Ginecologia Azienda Ospedaliera Universitaria di Parma, Parma, Italy
- Della Scuola di Specializzazione in Ostetricia e Ginecologia Presidente del CdS Ostetricia, Parma, Italy
| | - Wolfgang Henrich
- Department of Obstetrics, University Medical Center Berlin, Charité, Berlin, Germany
| | - Boris Tutschek
- Specialist in Gynecology and Obstetrics FMH, Focus Obstetrics and Feto-Maternal Medicine, Zurich, Switzerland
| | - Rasha Kamel
- Department of Obstetrics and Gynecology Maternal-Fetal medicine unit, Cairo University, Cairo, Egypt
| | - Christoph C Lees
- Imperial College London and Head of Fetal Medicine, Imperial College Healthcare NHS Trust, London, UK
- Department of Development & Regeneration, KU Leuven, Leuven, Belgium
| | - Ilenia Mappa
- Università di Roma Tor Vergata, Unità Operativa di Medicina Materno Fetale Ospedale Cristo Re Roma, Rome, Italy
| | | | - Wailam Lau
- Department of O&G, Kwong Wah Hospital, Hong Kong SAR, China
| | - Torbjorn Eggebo
- National center for fetal medicine, St.Olavs Hospital, Trondheim, Norway
| | - Reuven Achiron
- Department of Obstetrics and Gynecology, Ultrasound unit, Tel-Hashomer, Sackler School of Medicine, Tel-Aviv University, Ramat-Gan, Israel
| | - Cihat Sen
- Perinatal Medicine Foundation, Istanbul, Turkey
- Department of Perinatal Medicine, Memorial BAH Hospital, Istanbul, Turkey
- Department of Perinatal Medicine, Obstetrics and Gynecology, Istanbul University-Cerrahpasa, Istanbul, Turkey
| |
Collapse
|
11
|
Moncrieff G, Gyte GM, Dahlen HG, Thomson G, Singata-Madliki M, Clegg A, Downe S. Routine vaginal examinations compared to other methods for assessing progress of labour to improve outcomes for women and babies at term. Cochrane Database Syst Rev 2022; 3:CD010088. [PMID: 35244935 PMCID: PMC8896079 DOI: 10.1002/14651858.cd010088.pub3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND Routine vaginal examinations are undertaken at regular time intervals during labour to assess whether labour is progressing as expected. Unusually slow progress can be due to underlying problems, described as labour dystocia, or can be a normal variation of progress. Evidence suggests that if mother and baby are well, length of labour alone should not be used to decide whether labour is progressing normally. Other methods to assess labour progress include intrapartum ultrasound and monitoring external physical and behavioural cues. Vaginal examinations can be distressing for women, and overdiagnosis of dystocia can result in iatrogenic morbidity due to unnecessary intervention. It is important to establish whether routine vaginal examinations are effective, both as an accurate measure of physiological labour progress and to distinguish true labour dystocia, or whether other methods for assessing labour progress are more effective. This Cochrane Review is an update of a review first published in 2013. OBJECTIVES To compare the effectiveness, acceptability, and consequences of routine vaginal examinations compared with other methods, or different timings, to assess labour progress at term. SEARCH METHODS For this update, we searched Cochrane Pregnancy and Childbirth Trials Register (which includes trials from CENTRAL, MEDLINE, Embase, CINAHL, and conference proceedings) and ClinicalTrials.gov (28 February 2021). We also searched the reference lists of retrieved studies. SELECTION CRITERIA We included randomised controlled trials (RCTs) of vaginal examinations compared with other methods of assessing labour progress and studies assessing different timings of vaginal examinations. Quasi-RCTs and cluster-RCTs were eligible for inclusion. We excluded cross-over trials and conference abstracts. DATA COLLECTION AND ANALYSIS Two review authors independently assessed all studies identified by the search for inclusion in the review. Four review authors independently extracted data. Two review authors assessed risk of bias and certainty of the evidence using GRADE. MAIN RESULTS We included four studies that randomised a total of 755 women, with data analysed for 744 women and their babies. Interventions used to assess labour progress were routine vaginal examinations, routine ultrasound assessments, routine rectal examinations, routine vaginal examinations at different frequencies, and vaginal examinations as indicated. We were unable to conduct meta-analysis as there was only one study for each comparison. All studies were at high risk of performance bias due to difficulties with blinding. We assessed two studies as high risk of bias and two as low or unclear risk of bias for other domains. The overall certainty of the evidence assessed using GRADE was low or very low. Routine vaginal examinations versus routine ultrasound to assess labour progress (one study, 83 women and babies) Study in Turkey involving multiparous women with spontaneous onset of labour. Routine vaginal examinations may result in a slight increase in pain compared to routine ultrasound (mean difference -1.29, 95% confidence interval (CI) -2.10 to -0.48; one study, 83 women, low certainty evidence) (pain measured using a visual analogue scale (VAS) in reverse: zero indicating 'worst pain', 10 indicating no pain). The study did not assess our other primary outcomes: positive birth experience; augmentation of labour; spontaneous vaginal birth; chorioamnionitis; neonatal infection; admission to neonatal intensive care unit (NICU). Routine vaginal examinations versus routine rectal examinations to assess labour progress (one study, 307 women and babies) Study in Ireland involving women in labour at term. We assessed the certainty of the evidence as very low. Compared with routine rectal examinations, routine vaginal examinations may have little or no effect on: augmentation of labour (risk ratio (RR) 1.03, 95% CI 0.63 to 1.68; one study, 307 women); and spontaneous vaginal birth (RR 0.98, 95% CI 0.90 to 1.06; one study, 307 women). We found insufficient data to fully assess: neonatal infections (RR 0.33, 95% CI 0.01 to 8.07; one study, 307 babies); and admission to NICU (RR 1.32, 95% CI 0.47 to 3.73; one study, 307 babies). The study did not assess our other primary outcomes: positive birth experience; chorioamnionitis; maternal pain. Routine four-hourly vaginal examinations versus routine two-hourly examinations (one study, 150 women and babies) UK study involving primiparous women in labour at term. We assessed the certainty of the evidence as very low. Compared with routine two-hourly vaginal examinations, routine four-hourly vaginal examinations may have little or no effect, with data compatible with both benefit and harm, on: augmentation of labour (RR 0.97, 95% CI 0.60 to 1.57; one study, 109 women); and spontaneous vaginal birth (RR 1.02, 95% CI 0.83 to 1.26; one study, 150 women). The study did not assess our other primary outcomes: positive birth experience; chorioamnionitis; neonatal infection; admission to NICU; maternal pain. Routine vaginal examinations versus vaginal examinations as indicated (one study, 204 women and babies) Study in Malaysia involving primiparous women being induced at term. We assessed the certainty of the evidence as low. Compared with vaginal examinations as indicated, routine four-hourly vaginal examinations may result in more women having their labour augmented (RR 2.55, 95% CI 1.03 to 6.31; one study, 204 women). There may be little or no effect on: • spontaneous vaginal birth (RR 1.08, 95% CI 0.73 to 1.59; one study, 204 women); • chorioamnionitis (RR 3.06, 95% CI 0.13 to 74.21; one study, 204 women); • neonatal infection (RR 4.08, 95% CI 0.46 to 35.87; one study, 204 babies); • admission to NICU (RR 2.04, 95% CI 0.63 to 6.56; one study, 204 babies). The study did not assess our other primary outcomes of positive birth experience or maternal pain. AUTHORS' CONCLUSIONS Based on these findings, we cannot be certain which method is most effective or acceptable for assessing labour progress. Further large-scale RCT trials are required. These should include essential clinical and experiential outcomes. This may be facilitated through the development of a tool to measure positive birth experiences. Data from qualitative studies are also needed to fully assess whether methods to evaluate labour progress meet women's needs for a safe and positive labour and birth, and if not, to develop an approach that does.
Collapse
Affiliation(s)
- Gill Moncrieff
- School of Community Health and Midwifery, University of Central Lancashire, Preston, UK
| | - Gillian Ml Gyte
- Cochrane Pregnancy and Childbirth Group, Department of Women's and Children's Health, University of Liverpool, Liverpool, UK
| | - Hannah G Dahlen
- School of Nursing and Midwifery, Western Sydney University, Penrith, Australia
| | - Gill Thomson
- School of Community Health and Midwifery, University of Central Lancashire, Preston, UK
| | - Mandisa Singata-Madliki
- Effective Care Research Unit, University of the Witwatersrand/University of Fort Hare/East London Hospital complex, East London, South Africa
| | - Andrew Clegg
- Faculty of Health and Wellbeing, University of Central Lancashire, Preston, UK
| | - Soo Downe
- Research in Childbirth and Health (ReaCH) unit, University of Central Lancashire, Preston, UK
| |
Collapse
|
12
|
Kamel R, Negm S, Badr I, Kahrs BH, Eggebø TM, Iversen JK. Fetal head descent assessed by transabdominal ultrasound: a prospective observational study. Am J Obstet Gynecol 2022; 226:112.e1-112.e10. [PMID: 34389293 DOI: 10.1016/j.ajog.2021.07.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 07/28/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Determining fetal head descent, expressed as fetal head station and engagement is an essential part of monitoring progression in labor. Assessing fetal head station is based on the distal part of the fetal skull, whereas assessing engagement is based on the proximal part. Prerequisites for assisted vaginal birth are that the fetal head should be engaged and its lowermost part at or below the level of the ischial spines. The part of the fetal head above the pelvic inlet reflects the true descent of the largest diameter of the skull. In molded (reshaped) fetal heads, the leading bony part of the skull may be below the ischial spines while the largest diameter of the fetal skull still remains above the pelvic inlet. An attempt at assisted vaginal birth in such a situation would be associated with risks. Therefore, the vaginal or transperineal assessments of station should be supplemented with a transabdominal examination. We suggest a method for the assessment of fetal head descent with transabdominal ultrasound. OBJECTIVE To investigate the correlation between transabdominal and transperineal assessment of fetal head descent, and to study fetal head shape at different labor stages and head positions. STUDY DESIGN Women with term singleton cephalic pregnancies admitted to the labor ward for induction of labor or in spontaneous labor, at the Cairo University Hospital and Oslo University Hospital from December 2019 to December 2020 were included. Fetal head descent was assessed with transabdominal ultrasound as the suprapubic descent angle between a longitudinal line through the symphysis pubis and a line from the upper part of the symphysis pubis extending tangentially to the fetal skull. We compared measurements with transperineally assessed angle of progression and investigated interobserver agreement. We also measured the part of fetal head above and below the symphysis pubis at different labor stages. RESULTS The study population comprised 123 women, of whom 19 (15%) were examined before induction of labor, 8 (7%) in the latent phase, 52 (42%) in the active first stage and 44 (36%) in the second stage. The suprapubic descent angle and the angle of progression could be measured in all cases. The correlation between the transabdominal and transperineal measurements was -0.90 (95% confidence interval, -0.86 to -0.93). Interobserver agreement was examined in 30 women and the intraclass correlation coefficient was 0.98 (95% confidence interval, 0.95-0.99). The limits of agreement were from -9.5 to 7.8 degrees. The fetal head was more elongated in occiput posterior position than in non-occiput posterior positions in the second stage of labor. CONCLUSION We present a novel method of examining fetal head descent by assessing the proximal part of the fetal skull with transabdominal ultrasound. The correlation with transperineal ultrasound measurements was strong, especially early in labor. The fetal head was elongated in the occiput posterior position during the second stage of labor.
Collapse
|
13
|
Haberman S, Atallah F, Nizard J, Buhule O, Albert P, Gonen R, Ville Y, Paltieli Y. A Novel Partogram for Stages 1 and 2 of Labor Based on Fetal Head Station Measured by Ultrasound: A Prospective Multicenter Cohort Study. Am J Perinatol 2021; 38:e14-e20. [PMID: 32120420 DOI: 10.1055/s-0040-1702989] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
OBJECTIVE This study was aimed to describe continuous labor curves, including second stage, based on fetal head station. STUDY DESIGN We performed a prospective multicenter cohort study. The inclusion criteria were women with singleton uncomplicated cephalic term pregnancies in labor, who delivered vaginally. We used a device that combines ultrasound imaging with position-tracking technology to monitor the head station noninvasively throughout labor. We collected data on demographics, labor parameters, and delivery and neonatal outcomes. RESULTS A total of 613 women delivered vaginally, 327 (53.3%) were nulliparous, while 286 (46.7%) were multiparous. Time to delivery (TTD) diminished progressively with descent of the fetal head. When the head is engaged, the labor curve of multiparous women demonstrated a more prominent downward shift in curve as compared with nulliparous women. When comparing multipara and nullipara at engagement level, the median TTD was 1 and 1.62 hours, respectively. In 95% of women with unengaged head during the second stage, TTD of nulliparous and multiparous women were less than 3.8 and 3 hours, respectively. CONCLUSION While current labor curves end at full dilatation, the described curves were developed throughout stages 1 and 2 of labor. The TTD, according to the station curves, shows an acceleration of labor, once passed the engagement level, especially in multiparous women.
Collapse
Affiliation(s)
- Shoshana Haberman
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Maimonides Medical Center, Brooklyn, New York
| | - Fouad Atallah
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Maimonides Medical Center, Brooklyn, New York
| | - Jacky Nizard
- Service de gynécologie obstétrique, Groupe hospitalier Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris, Sorbonne Universités, Paris, France
| | - Olive Buhule
- National Institutes of Health, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland
| | - Paul Albert
- National Institutes of Health, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, Maryland
| | - Ron Gonen
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Bnai Zion Medical Center, Technion, Israel Institute of Technology, Israel
| | - Yves Ville
- Department of Obstetrics and Fetal Medicine, Hôpital Necker-Enfants-Malade, Paris, France
| | - Yoav Paltieli
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, Bnai Zion Medical Center, Technion, Israel Institute of Technology, Israel
| |
Collapse
|
14
|
Applications of Advanced Ultrasound Technology in Obstetrics. Diagnostics (Basel) 2021; 11:diagnostics11071217. [PMID: 34359300 PMCID: PMC8306830 DOI: 10.3390/diagnostics11071217] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 06/28/2021] [Accepted: 07/03/2021] [Indexed: 12/21/2022] Open
Abstract
Over the years, there have been several improvements in ultrasound technologies including high-resolution ultrasonography, linear transducer, radiant flow, three-/four-dimensional (3D/4D) ultrasound, speckle tracking of the fetal heart, and artificial intelligence. The aims of this review are to evaluate the use of these advanced technologies in obstetrics in the midst of new guidelines on and new techniques of obstetric ultrasonography. In particular, whether these technologies can improve the diagnostic capability, functional analysis, workflow, and ergonomics of obstetric ultrasound examinations will be discussed.
Collapse
|
15
|
Sweed MS, Allam IF, Ashoush SA, Marwan OA, NasrElDin EA. Sonopartogram versus conventional partogram for monitoring progress of labor: a prospective observational study. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2020. [DOI: 10.1186/s43055-020-00295-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Repeated digital vaginal examination during labor may be uncomfortable for women and increases the risk of ascending infection. Transperineal ultrasound can assess fetal head descent, position, and cervical dilatation without these side effects. This study was conducted to evaluate the accuracy of transperineal ultrasound in monitoring labor progress.
Results
The study included 40 primigravida women in labor. Fair correlation was found between the assessment of fetal head station by vaginal examination (VE) and fetal head perineal distance (HPD) by transperineal ultrasound (TPUS) (Kendall’s tau-b (τ) = − 0.299, 95% CI = − 0.479 to − 0.0863, p value = .0063) (Spearman rho = − .3844, p value = .0143; r2 = 0.1478). Strong correlation was found between the cervical dilatation assessed by VE and by TPUS (Pearson’s r = .8601, 95% CI = 0.7493 to 0.9240, p value < .0001, r2 = 0.7396). There is moderate agreement between VE and TPUS as regards the assessment of head position on the face-clock [weighted kappa (κ) = .557, 95% CI = .362 to.753].
Conclusion
Transperineal ultrasound can be used as an alternative to repeated digital examination for assessment of labor progress.
Collapse
|
16
|
Kwan AHW, Chaemsaithong P, Tse WT, Appiah K, Chong KC, Leung TY, Poon LC. Feasibility, Reliability, and Agreement of Transperineal Ultrasound Measurement: Results from a Longitudinal Cohort Study. Fetal Diagn Ther 2020; 47:1-10. [PMID: 32634805 DOI: 10.1159/000507549] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2019] [Accepted: 03/25/2020] [Indexed: 11/19/2022]
Abstract
OBJECTIVES To evaluate the feasibility, reliability, and agreement of serial transperineal ultrasound (TPU) assessment of fetal head station (parasagittal angle of progression [psAOP], head-perineum distance [HPD], and head-symphysis distance [HSD]) and sonographic cervical dilatation (SCD), compared to fetal head station and cervical dilatation determined by vaginal examination, respectively. METHODS This was a prospective longitudinal study in singleton pregnancies undergoing induction of labor at term. Paired assessment of fetal head station and cervical dilatation by vaginal examination, with TPU assessment of psAOP, HPD, HSD, and SCD was made serially. Feasibility, correlation, reliability, and agreement were determined. RESULTS 1,139 paired measurements among 326 women were included. psAOP and HPD were achievable in all assessments. HSD was not achievable in 3.4% (11/326) due to high fetal head station. Fetal head station by vaginal examination was positively correlated with psAOP (rho = 0.70) but negatively correlated with HPD (rho = -0.57) and HSD (rho = -0.52). The feasibility to measure SCD reduced as cervical dilatation increased. Cervical dilatation and SCD were positively correlated (rho = 0.96) with strong agreement (concordant correlation coefficient = 0.925). CONCLUSIONS Measurements of psAOP and HPD are feasible and correlate significantly with fetal head station by vaginal examination. Measurement of HSD is not feasible when fetal head station is high. Measurement of SCD is feasible, but it is more difficult in the advanced stage of labor. The correlation, reliability, and agreement between SCD and cervical dilatation by vaginal examination are high.
Collapse
Affiliation(s)
- Angel H W Kwan
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Piya Chaemsaithong
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Wing Ting Tse
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Kubi Appiah
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Ka Chun Chong
- The Jockey Club School of Public Health and Primary Care Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Tak Yeung Leung
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Hong Kong
| | - Liona C Poon
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, Hong Kong,
| |
Collapse
|
17
|
Wilkinson M, Usman S, Barton H, Lees CC. The views of pregnant women, midwives, and a women's panel on intrapartum ultrasound research: A pilot study. Australas J Ultrasound Med 2019; 22:186-190. [DOI: 10.1002/ajum.12162] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Affiliation(s)
| | - Sana Usman
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital Imperial College Healthcare NHS Trust Du Cane Road London W12 0HS UK
| | - Helen Barton
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital Imperial College Healthcare NHS Trust Du Cane Road London W12 0HS UK
| | - Christoph C. Lees
- Imperial College London South Kensington, London SW7 2AZ UK
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital Imperial College Healthcare NHS Trust Du Cane Road London W12 0HS UK
- Department of Development and Regeneration KU Leuven UZ Leuven, Gasthuisberg campus, Herestraat Leuven 49, 3000 Belgium
| |
Collapse
|
18
|
Usman S, Barton H, Wilhelm-Benartzi C, Lees CC. Ultrasound is better tolerated than vaginal examination in and before labour. Aust N Z J Obstet Gynaecol 2019; 59:362-366. [PMID: 30024022 DOI: 10.1111/ajo.12864] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Accepted: 06/19/2018] [Indexed: 12/17/2022]
Abstract
BACKGROUND Intrapartum ultrasound has been proposed as a method of assessing labour progress but its acceptability has not been comprehensively assessed. AIMS We evaluated the acceptability of intrapartum ultrasound in women having vaginal examination (VE) and ultrasound (US) assessment (transabdominal (TA) and transperineal (TP)) prior to delivery, with and without regional analgesia (RA). MATERIALS AND METHODS Women at 24-42 weeks gestation were included in a prospective observational cohort study. The acceptability of digital VE and TP US were assessed pre- and post-examination using the modified validated Wijma Delivery Experience Questionnaire. Acceptability scores ranged 6-36 (6 being most and 36 being least positive) in six domains: positive-trust and relax, negative-harmful to baby, worrying, painful, intrusive. RESULTS Of 119 women recruited, 104 completed both pre- and post-assessment questionnaires. Eighty-nine per cent of women were nulliparous with median gestation 40 + 2 weeks (25-42+1 ). Thirty-two per cent had RA before assessment, 91% in total. The combined acceptability scores of both negative and positive experiences (6 = most acceptable, 36 = least acceptable) for VE and US pre-assessment were 15 and 7 respectively (P < 0.0001: Mann-Whitney U-test). VE was associated with less positive / more negative domain scoring post-assessment 12 and 6, respectively (P < 0.0001). Although RA made no difference to the perceived experience pre-VE (P = 0.9), post-VE, women with RAs considered VEs more acceptable than those without RA (P = 0.0022). CONCLUSION(S) This is the first study to comprehensively assess the acceptability of VE and intrapartum US. US assessment prior to delivery is more acceptable than VE. RA ameliorated the negative experience of the VE post-assessment.
Collapse
Affiliation(s)
- Sana Usman
- Department of Surgery and Cancer, Imperial College London, London, UK
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - Helen Barton
- Department of Surgery and Cancer, Imperial College London, London, UK
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - Charlotte Wilhelm-Benartzi
- Wales Cancer Trials Unit Centre for Trials Research, College of Biomedical & Life Sciences, Cardiff University, Cardiff, South Glamorgan, UK
| | - Christoph C Lees
- Department of Surgery and Cancer, Imperial College London, London, UK
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Imperial College Healthcare NHS Trust, London, UK
| |
Collapse
|