1
|
Kostyrko B, Rubarth K, Althoff C, Poch FGM, Neizert CA, Zibell M, Gebauer B, Lehmann KS, Niehues SM, Mews J, Diekhoff T, Pohlan J. Computed tomography-based thermography (CTT) in microwave ablation: prediction of the heat ablation zone in the porcine liver. Insights Imaging 2023; 14:189. [PMID: 37962712 PMCID: PMC10645839 DOI: 10.1186/s13244-023-01537-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 10/09/2023] [Indexed: 11/15/2023] Open
Abstract
OBJECTIVES The aim of the study was to investigate computed tomography-based thermography (CTT) for ablation zone prediction in microwave ablation (MWA). METHODS CTT was investigated during MWA in an in vivo porcine liver. For CTT, serial volume scans were acquired every 30 s during ablations and every 60 s immediately after MWA. After the procedure, contrast-enhanced computed tomography (CECT) was performed. After euthanasia, the liver was removed for sampling and further examination. Color-coded CTT maps were created for visualization of ablation zones, which were compared with both CECT and macroscopy. Average CT attenuation values in Hounsfield units (HU) were statistically correlated with temperatures using Spearman's correlation coefficient. CTT was retrospectively evaluated in one patient who underwent radiofrequency ablation (RFA) treatment of renal cell carcinoma. RESULTS A significant correlation between HU and temperature was found with r = - 0.77 (95% confidence interval (CI), - 0.89 to - 0.57) and p < 0.001. Linear regression yielded a slope of - 1.96 HU/°C (95% CI, - 2.66 to - 1.26). Color-coded CTT maps provided superior visualization of ablation zones. CONCLUSION Our results show that CTT allows visualization of the ablation area and measurement of its size and is feasible in patients, encouraging further exploration in a clinical setting. CRITICAL RELEVANCE STATEMENT CT-based thermography research software allows visualization of the ablation zone and is feasible in patients, encouraging further exploration in a clinical setting to assess risk reduction of local recurrence.
Collapse
Affiliation(s)
- Bogdan Kostyrko
- Department of Radiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany.
| | - Kerstin Rubarth
- Institute of Biometry and Clinical Epidemiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
- Institute of Medical Informatics, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Christian Althoff
- Department of Radiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Franz Gerd Martin Poch
- Department of General and Visceral Surgery, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Hindenburgdamm 30, 12200, Berlin, Germany
| | - Christina Ann Neizert
- Department of General and Visceral Surgery, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Hindenburgdamm 30, 12200, Berlin, Germany
| | - Miriam Zibell
- Department of General and Visceral Surgery, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Hindenburgdamm 30, 12200, Berlin, Germany
| | - Bernhard Gebauer
- Department of Radiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Kai Siegfried Lehmann
- Department of General and Visceral Surgery, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Hindenburgdamm 30, 12200, Berlin, Germany
| | - Stefan Markus Niehues
- Department of Radiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Jürgen Mews
- Canon Medical Systems Europe BV, Global Research & Development Center, Amstelveen, the Netherlands
| | - Torsten Diekhoff
- Department of Radiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
| | - Julian Pohlan
- Department of Radiology, Freie Universität Berlin and Humboldt-Universität Zu Berlin, Charitéplatz 1, 10117, Berlin, Germany
- Berlin Institute of Health at Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany
| |
Collapse
|
2
|
Alemaryeen A, Noghanian S. A Survey of the Thermal Analysis of Implanted Antennas for Wireless Biomedical Devices. MICROMACHINES 2023; 14:1894. [PMID: 37893331 PMCID: PMC10609145 DOI: 10.3390/mi14101894] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 09/22/2023] [Accepted: 09/28/2023] [Indexed: 10/29/2023]
Abstract
Wireless implantable biomedical devices (IBDs) are emerging technologies used to enhance patient treatment and monitoring. The performance of wireless IBDs mainly relies on their antennas. Concerns have emerged regarding the potential of wireless IBDs to unintentionally cause tissue heating, leading to potential harm to surrounding tissue. The previous literature examined temperature estimations and specific absorption rates (SAR) related to IBDs, mainly within the context of thermal therapy applications. Often, these studies consider system parameters such as frequency, input power, and treatment duration without isolating their individual impacts. This paper provides an extensive literature review, focusing on key antenna design parameters affecting heat distribution in IBDs. These parameters encompass antenna design, treatment settings, testing conditions, and thermal modeling. The research highlights that input power has the most significant impact on localized temperature, with operating frequency ranked as the second most influential factor. While emphasizing the importance of understanding tissue heating and optimizing antennas for improved power transfer, these studies also illuminate existing knowledge gaps. Excessive tissue heat can lead to harmful effects such as vaporization, carbonization, and irreversible tissue changes. To ensure patient safety and reduce expenses linked to clinical trials, employing simulation-driven approaches for IBD antenna design and optimization is essential.
Collapse
Affiliation(s)
- Ala Alemaryeen
- Department of Computer Engineering and Communication, Tafila Technical University, Tafila 66110, Jordan
| | | |
Collapse
|
3
|
Kostyrko B, Rubarth K, Althoff C, Zibell M, Neizert CA, Poch F, Torsello GF, Gebauer B, Lehmann K, Niehues SM, Mews J, Diekhoff T, Pohlan J. Evaluation of Different Registration Algorithms to Reduce Motion Artifacts in CT-Thermography (CTT). Diagnostics (Basel) 2023; 13:2076. [PMID: 37370971 DOI: 10.3390/diagnostics13122076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 06/06/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
Computed tomography (CT)-based Thermography (CTT) is currently being investigated as a non-invasive temperature monitoring method during ablation procedures. Since multiple CT scans with defined time intervals were acquired during this procedure, interscan motion artifacts can occur between the images, so registration is required. The aim of this study was to investigate different registration algorithms and their combinations for minimizing inter-scan motion artifacts during thermal ablation. Four CTT datasets were acquired using microwave ablation (MWA) of normal liver tissue performed in an in vivo porcine model. During each ablation, spectral CT volume scans were sequentially acquired. Based on initial reconstructions, rigid or elastic registration, or a combination of these, were carried out and rated by 15 radiologists. Friedman's test was used to compare rating results in reader assessments and revealed significant differences for the ablation probe movement rating only (p = 0.006; range, 5.3-6.6 points). Regarding this parameter, readers assessed rigid registration as inferior to other registrations. Quantitative analysis of ablation probe movement yielded a significantly decreased distance for combined registration as compared with unregistered data. In this study, registration was found to have the greatest influence on ablation probe movement, with connected registration being superior to only one registration process.
Collapse
Affiliation(s)
- Bogdan Kostyrko
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Kerstin Rubarth
- Institute for Biometry and Clinical Epidemiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
- Berlin Institute of Health, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10178 Berlin, Germany
| | - Christian Althoff
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Miriam Zibell
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Christina Ann Neizert
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Franz Poch
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Giovanni Federico Torsello
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Bernhard Gebauer
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Kai Lehmann
- Department of General and Visceral Surgery, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 12203 Berlin, Germany
| | - Stefan Markus Niehues
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Jürgen Mews
- Canon Medical Systems Europe BV, Global Research & Development Center, 2718 RP Zoetermeer, The Netherlands
| | - Torsten Diekhoff
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
| | - Julian Pohlan
- Department of Radiology, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10117 Berlin, Germany
- Berlin Institute of Health, Charité-Universitätsmedizin Berlin, Humboldt-Universität zu Berlin, Freie Universität Berlin, 10178 Berlin, Germany
| |
Collapse
|
4
|
Study on the Microwave Ablation Effect of Inflated Porcine Lung. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12125916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
(1) Background: Microwave ablation (MWA) has an efficient killing effect on primary and metastatic lung cancer. However, the treatment effect will be affected by the air in the lung, which makes it very difficult to accurately predict and control the ablation area; (2) Methods: In this paper, in vitro experiments combined with simulations are used to study the microwave ablation area of inflated porcine lung. The in vitro experiment is divided into inflated group and deflated group, combined with different ablation power (40 W, 50 W, 60 W) and ablation time (100 s, 200 s, 300 s) for experiment, each power and time combination are repeated five times. A total of 90 ablation experiments were performed. The simulation experiment uses COMSOL Multiphysics software to simulate the microwave ablation area of the inflated lung; (3) Results and Conclusions: When the ablation power is 40 W, 50 W, and 60 W, the average long diameter of the deflated group are 20.8–30.9%, 7.6–22.6%, 10.4–19.8% larger than those of the inflated group, respectively; the average short diameter of the deflated group is 24.5–41.4%, 31.6–45.7%, 27.3–42.9% larger than that of the inflated group. The results show that the ablation area of inflated lung is smaller than deflated lung, which is mainly due to the smaller ablation short diameter.
Collapse
|
5
|
Chiang J, Song L, Abtin F, Rahmat-Samii Y. Efficacy of Lung-Tuned Monopole Antenna for Microwave Ablation: Analytical Solution and Validation in a Ventilator-Controlled ex Vivo Porcine Lung Model. IEEE JOURNAL OF ELECTROMAGNETICS, RF AND MICROWAVES IN MEDICINE AND BIOLOGY 2021; 5:295-304. [PMID: 35706532 PMCID: PMC9191847 DOI: 10.1109/jerm.2021.3066103] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The goal of this study was to optimize a lung-tuned monopole antenna to deliver microwave energy at 2.45 GHz into a novel ventilator-controlled ex vivo lung model. An analytic and parametric approach was utilized to create an optimized monopole antenna that was impedance-matched to aerated lung tissue. This lung-tuned antenna was then fabricated using a copper 0.085" semi-rigid copper coaxial cable. For validation, the lung-tuned antenna was inserted centrally into lobes of a ex vivo porcine lung that was fully inflated to physiologically appropriate volumes. Microwave ablations were then created at 50 and 100 W for 1 minute and 5 minutes. Reflected power, cross sectional ablation sizes and spherical shape of the lung-tuned antenna were compared against a liver-tuned antenna in the ventilator-controlled ex vivo lung tissue. The study showed that the lung-tuned antennas delivered energy significantly more efficiently, with less reflected power, compared to the conventionally-used liver-tuned antennas at 50 W at 1 minute (11.8±3.0 vs 16.3±3.1 W; p value=0.03) and 5 minutes (16.2±2.8 vs 19.4±2.9 W; p value=0.04), although this was only true using 100 W at the 1 minute time point (29.0±3.5 vs 38.0±5.3 W; p value=0.02). While overall ablation zone sizes were comparable between the two types of antenna, the lung-tuned antenna did create a significantly more spherical ablation zone compared to the liver-tuned antenna at the 1 minute, 50 W setting (aspect ratio: 0.43±0.07 vs 0.38±0.04; p value=0.04). In both antenna groups, there was a significant rise in the ablation zone aspect ratio between 1 and 5 minutes, indicating that higher power and time settings can increase the spherical shape of ablation zones when using tuned antennas. Adapting this combined analytic and parametric approach to antenna design can be implemented in adaptive tissue-tuning for real-time microwave ablation optimization in lung tissue.
Collapse
Affiliation(s)
- Jason Chiang
- Department of Radiology, Ronald Reagan UCLA Medical Center
| | - Lingnan Song
- Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095 USA
| | | | - Yahya Rahmat-Samii
- Department of Electrical and Computer Engineering, University of California, Los Angeles, Los Angeles, CA 90095 USA
| |
Collapse
|
6
|
Zhu JE, Chen YC, Yu SY, Xu HX. The first experience of ultrasound-guided percutaneous microwave ablation for extracranial schwannoma of the cervical vagus nerve in carotid space and treatment response evaluation with contrast-enhanced imaging. Clin Hemorheol Microcirc 2021; 80:437-446. [PMID: 34864650 DOI: 10.3233/ch-211301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Schwannoma is a benign tumor that originates from Schwann cells in the nerve sheathing of cranial, other peripheral, or autonomic nerves. Patients often present with painless mass as the chief complaint. The main symptoms of this tumor are related to its size and specific nerve origin. At present, the pretreatment diagnosis is mainly made by ultrasound, CT, MR, or biopsy, and the main treatment is surgical resection. We reported a new treatment method for cervical schwannoma in a 65-year-old woman with a history of non-small cell lung cancer (NSCLC). When the patient's neck mass was initially found with hoarseness and severe cough, it was considered as cervical lymph node metastasis of lung cancer due to her medical history. And she was diagnosed with schwannoma by core-needle biopsy after chemotherapy failed and the tumor shrank after the radiotherapy with no improvement of the clinical symptoms. After considering the physical condition, the patients were treated in our department for minimal invasiveness treatment. The patient was definitively diagnosed with cervical vagus schwannoma and was treated with ultrasound-guided microwave ablation of schwannoma under general anesthesia with systematic evaluation and improved preoperative examination. Her condition was stable, and the symptoms of severe cough disappeared after anesthesia resuscitation and the ablation. The tumor continued to shrink after the operation with no recurrence of cough symptoms. Ultrasound-guided percutaneous microwave ablation (MWA) for cervical vagus schwannomas might be a minimally invasive, effective, and relatively safe alternative to conventional treatment for those patients with severe symptoms.
Collapse
Affiliation(s)
- Jing-E Zhu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Engineering Research Center of Ultrasound Diagnosis and Treatment, National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Yun-Chao Chen
- Department of Medical Ultrasound, Xiang'an Hospital of Xiamen University, Xiamen, China
| | - Song-Yuan Yu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Engineering Research Center of Ultrasound Diagnosis and Treatment, National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Hui-Xiong Xu
- Center of Minimally Invasive Treatment for Tumor, Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Shanghai, China.,Ultrasound Research and Education Institute, Clinical Research Center for Interventional Medicine, School of Medicine, Tongji University, Shanghai, China.,Engineering Research Center of Ultrasound Diagnosis and Treatment, National Clinical Research Center for Interventional Medicine, Shanghai, China
| |
Collapse
|
7
|
Huang H, Zhang L, Moser MAJ, Zhang W, Zhang B. A review of antenna designs for percutaneous microwave ablation. Phys Med 2021; 84:254-264. [PMID: 33773908 DOI: 10.1016/j.ejmp.2021.03.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 03/03/2021] [Accepted: 03/06/2021] [Indexed: 12/15/2022] Open
Abstract
Microwave (MW) antenna is a key element in microwave ablation (MWA) treatments as the means that energy is delivered in a focused manner to the tumor and its surrounding area. The energy delivered results in a rise in temperature to a lethal level, resulting in cell death in the ablation zone. The delivery of energy and hence the success of MWA is closely dependent on the structure of the antennas. Therefore, three design criteria, such as expected ablation zone pattern, efficiency of energy delivery, and minimization of the diameter of the antennas have been the focus along the evolution of the MW antenna. To further improve the performance of MWA in the treatment of various tumors through inventing novel antennas, this article reviews the state-of-the-art and summarizes the development of MW antenna designs regarding the three design criteria.
Collapse
Affiliation(s)
- Hangming Huang
- Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China
| | - Lifeng Zhang
- Department of General Surgery, the First Affiliated Hospital of Soochow University,Soochow University, Jiangsu, China
| | - Michael A J Moser
- Department of Surgery, College of Medicine, University of Saskatchewan, Saskatoon, Canada
| | - Wenjun Zhang
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, Canada
| | - Bing Zhang
- Energy-based Tumor Ablation Laboratory, School of Mechatronic Engineering and Automation, Shanghai University, Shanghai, China.
| |
Collapse
|
8
|
Liu HX, Cheng YY, Tian Z, Gao X, Zhang M, Nan Q. Flow field study of radiofrequency ablation of renal sympathetic nerve: Numerical simulation and PIV experiments. Electromagn Biol Med 2020; 39:262-272. [DOI: 10.1080/15368378.2020.1793167] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Hong-Xing Liu
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| | - Yan-Yan Cheng
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| | - Zhen Tian
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| | - Xiang Gao
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| | - Meng Zhang
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| | - Qun Nan
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, China
| |
Collapse
|