1
|
Pakula M. What kind of waves are measured in trabecular bone? ULTRASONICS 2022; 123:106692. [PMID: 35176689 DOI: 10.1016/j.ultras.2022.106692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 01/06/2022] [Accepted: 01/17/2022] [Indexed: 06/14/2023]
Abstract
The paper discusses the fundamental mechanisms underlying the interaction between ultrasound and trabecular bone, which is considered a two-phase material. When fluid-saturated cancellous bone is interrogated by ultrasound, in some cases, one or two wave modes are observed. Many authors claim that these waves correspond to the fast and slow waves predicted by Biot's theory of elastic wave propagation in fluid-saturated porous media. Within our analysis of the physical conditions, predictions of the existing two-phase models of the propagation of ultrasonic waves in the material as well as numerical simulations for fluid-saturated trabecular bone were performed. On the basis of the theoretical results (from numerical studies) and arguments presented in this paper, we aimed to answer the question of whether two waves observed in ultrasonic wave transmission studies can be interpreted as the fast and slow waves predicted by Biot's theory.
Collapse
Affiliation(s)
- Michal Pakula
- Faculty of Mechatronics, Kazimierz Wielki University in Bydgoszcz, Poland.
| |
Collapse
|
2
|
Yoon K, Lee W, Croce P, Cammalleri A, Yoo SS. Multi-resolution simulation of focused ultrasound propagation through ovine skull from a single-element transducer. Phys Med Biol 2018; 63:105001. [PMID: 29658494 DOI: 10.1088/1361-6560/aabe37] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Transcranial focused ultrasound (tFUS) is emerging as a non-invasive brain stimulation modality. Complicated interactions between acoustic pressure waves and osseous tissue introduce many challenges in the accurate targeting of an acoustic focus through the cranium. Image-guidance accompanied by a numerical simulation is desired to predict the intracranial acoustic propagation through the skull; however, such simulations typically demand heavy computation, which warrants an expedited processing method to provide on-site feedback for the user in guiding the acoustic focus to a particular brain region. In this paper, we present a multi-resolution simulation method based on the finite-difference time-domain formulation to model the transcranial propagation of acoustic waves from a single-element transducer (250 kHz). The multi-resolution approach improved computational efficiency by providing the flexibility in adjusting the spatial resolution. The simulation was also accelerated by utilizing parallelized computation through the graphic processing unit. To evaluate the accuracy of the method, we measured the actual acoustic fields through ex vivo sheep skulls with different sonication incident angles. The measured acoustic fields were compared to the simulation results in terms of focal location, dimensions, and pressure levels. The computational efficiency of the presented method was also assessed by comparing simulation speeds at various combinations of resolution grid settings. The multi-resolution grids consisting of 0.5 and 1.0 mm resolutions gave acceptable accuracy (under 3 mm in terms of focal position and dimension, less than 5% difference in peak pressure ratio) with a speed compatible with semi real-time user feedback (within 30 s). The proposed multi-resolution approach may serve as a novel tool for simulation-based guidance for tFUS applications.
Collapse
Affiliation(s)
- Kyungho Yoon
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, United States of America
| | | | | | | | | |
Collapse
|
3
|
Lee KI. Relationships of linear and nonlinear ultrasound parameters with porosity and trabecular spacing in trabecular-bone-mimicking phantoms. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 140:EL528. [PMID: 28040043 DOI: 10.1121/1.4972530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The speed of sound (SOS), the normalized broadband ultrasound attenuation (nBUA), and the nonlinear parameter (B/A) were measured in 18 trabecular-bone-mimicking phantoms consisting of water-saturated aluminum foams. The strong slow wave and the very weak fast wave were consistently observed in the signals transmitted through all of the phantoms. It was found that the SOS increased as the porosity and the trabecular spacing increased. In contrast, both the nBUA and the B/A showed opposite dependences on the porosity and the trabecular spacing. All three ultrasound parameters exhibited high correlation coefficients with the porosity and the trabecular spacing.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of Korea
| |
Collapse
|
4
|
Groopman AM, Katz JI, Holland MR, Fujita F, Matsukawa M, Mizuno K, Wear KA, Miller JG. Conventional, Bayesian, and Modified Prony's methods for characterizing fast and slow waves in equine cancellous bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:594-604. [PMID: 26328678 PMCID: PMC4529434 DOI: 10.1121/1.4923366] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Revised: 06/16/2015] [Accepted: 06/21/2015] [Indexed: 05/28/2023]
Abstract
Conventional, Bayesian, and the modified least-squares Prony's plus curve-fitting (MLSP + CF) methods were applied to data acquired using 1 MHz center frequency, broadband transducers on a single equine cancellous bone specimen that was systematically shortened from 11.8 mm down to 0.5 mm for a total of 24 sample thicknesses. Due to overlapping fast and slow waves, conventional analysis methods were restricted to data from sample thicknesses ranging from 11.8 mm to 6.0 mm. In contrast, Bayesian and MLSP + CF methods successfully separated fast and slow waves and provided reliable estimates of the ultrasonic properties of fast and slow waves for sample thicknesses ranging from 11.8 mm down to 3.5 mm. Comparisons of the three methods were carried out for phase velocity at the center frequency and the slope of the attenuation coefficient for the fast and slow waves. Good agreement among the three methods was also observed for average signal loss at the center frequency. The Bayesian and MLSP + CF approaches were able to separate the fast and slow waves and provide good estimates of the fast and slow wave properties even when the two wave modes overlapped in both time and frequency domains making conventional analysis methods unreliable.
Collapse
Affiliation(s)
- Amber M Groopman
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63130, USA
| | - Jonathan I Katz
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63130, USA
| | - Mark R Holland
- Department of Radiology and Imaging Sciences, Indiana University-Purdue University School of Medicine, Indianapolis, Indiana 46202, USA
| | - Fuminori Fujita
- Laboratory of Ultrasonic Electronics, Research Center for Wave Electronics, Doshisha University, Kyotanabe, 610-0321 Kyoto, Japan
| | - Mami Matsukawa
- Laboratory of Ultrasonic Electronics, Research Center for Wave Electronics, Doshisha University, Kyotanabe, 610-0321 Kyoto, Japan
| | - Katsunori Mizuno
- Underwater Technology Research Center, The University of Tokyo, Meguro-ku, Tokyo 153-8505, Japan
| | - Keith A Wear
- Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland 20993, USA
| | - James G Miller
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63130, USA
| |
Collapse
|
5
|
Lin L, Lin W, Qin YX. Enhanced correlation between quantitative ultrasound and structural and mechanical properties of bone using combined transmission-reflection measurement. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 137:1144-1152. [PMID: 25786930 PMCID: PMC4368590 DOI: 10.1121/1.4906830] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Revised: 10/28/2014] [Accepted: 12/08/2014] [Indexed: 05/28/2023]
Abstract
Quantitative ultrasound (QUS) is capable of predicting the principal structural orientation of trabecular bone; this orientation is highly correlated with the mechanical strength of trabecular bone. Irregular shape of bone, however, would increase variation in such a prediction, especially under human in vivo measurement. This study was designed to combine transmission and reflection modes of QUS measurement to improve the prediction for the structural and mechanical properties of trabecular bone. QUS, mechanical testing, and micro computed tomography (μCT) scanning were performed on 24 trabecular bone cubes harvested from a bovine distal femur to obtain the mechanical and structural parameters. Transmission and reflection modes of QUS measurement in the transverse and frontal planes were performed in a confined 60° angle range with 5° increment. The QUS parameters, attenuation (ATT) and velocity (UV), obtained from transmission mode, were normalized to the specimen thickness acquired from reflection mode. Analysis of covariance showed that the combined transmission-reflection modes improved prediction for the structural and Young's modulus of bone in comparison to the traditional QUS measurement performed only in the medial-lateral orientation. In the transverse plane, significant improvement between QUS and μCT was found in ATT vs bone surface density (BS/BV) (p < 0.05), ATT vs trabecular thickness (Tb.Th) (p < 0.01), ATT vs degree of anisotropy (DA) (p < 0.05), UV vs trabecular bone number (Tb.N) (p < 0.05), and UV vs Tb.Th (p < 0.001). In the frontal plane, significant improvement was found in ATT vs structural model index (SMI) (p < 0.01), ATT vs bone volume fraction (BV/TV) (p < 0.01), ATT vs BS/BV (p < 0.001), ATT vs Tb.Th (p < 0.001), ATT vs DA (p < 0.001), and ATT vs modulus (p < 0.001), UV vs SMI (p < 0.01), UV vs BV/TV (p < 0.05), UV vs BS/BV (p < 0.05), UV vs Tb.Th (p < 0.01), UV vs trabecular spacing (p < 0.05), and UV vs modulus (p < 0.01). These data suggested that the combined transmission-reflection QUS method is capable of providing information more relevant to the structural and mechanical properties of trabecular bone.
Collapse
Affiliation(s)
- Liangjun Lin
- Orthopaedic Bioengineering Research Laboratory, Department of Biomedical Engineering, Bioengineering Building, Room 215, Stony Brook University, Stony Brook, New York 11794-5281
| | - Wei Lin
- Orthopaedic Bioengineering Research Laboratory, Department of Biomedical Engineering, Bioengineering Building, Room 215, Stony Brook University, Stony Brook, New York 11794-5281
| | - Yi-Xian Qin
- Orthopaedic Bioengineering Research Laboratory, Department of Biomedical Engineering, Bioengineering Building, Room 215, Stony Brook University, Stony Brook, New York 11794-5281
| |
Collapse
|
6
|
Langton CM, Wille ML, Flegg MB. A deconvolution method for deriving the transit time spectrum for ultrasound propagation through cancellous bone replica models. Proc Inst Mech Eng H 2014; 228:321-9. [DOI: 10.1177/0954411914523582] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The acceptance of broadband ultrasound attenuation for the assessment of osteoporosis suffers from a limited understanding of ultrasound wave propagation through cancellous bone. It has recently been proposed that the ultrasound wave propagation can be described by a concept of parallel sonic rays. This concept approximates the detected transmission signal to be the superposition of all sonic rays that travel directly from transmitting to receiving transducer. The transit time of each ray is defined by the proportion of bone and marrow propagated. An ultrasound transit time spectrum describes the proportion of sonic rays having a particular transit time, effectively describing lateral inhomogeneity of transit times over the surface of the receiving ultrasound transducer. The aim of this study was to provide a proof of concept that a transit time spectrum may be derived from digital deconvolution of input and output ultrasound signals. We have applied the active-set method deconvolution algorithm to determine the ultrasound transit time spectra in the three orthogonal directions of four cancellous bone replica samples and have compared experimental data with the prediction from the computer simulation. The agreement between experimental and predicted ultrasound transit time spectrum analyses derived from Bland–Altman analysis ranged from 92% to 99%, thereby supporting the concept of parallel sonic rays for ultrasound propagation in cancellous bone. In addition to further validation of the parallel sonic ray concept, this technique offers the opportunity to consider quantitative characterisation of the material and structural properties of cancellous bone, not previously available utilising ultrasound.
Collapse
Affiliation(s)
- Christian M Langton
- Biomedical Engineering & Medical Physics Discipline, Science & Engineering Faculty and Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia
| | - Marie-Luise Wille
- Biomedical Engineering & Medical Physics Discipline, Science & Engineering Faculty and Institute of Health & Biomedical Innovation, Queensland University of Technology, Brisbane, QLD, Australia
| | - Mark B Flegg
- Oxford Centre for Collaborative Applied Mathematics, University of Oxford, Oxford, UK
| |
Collapse
|
7
|
Lin L, Oon HY, Lin W, Qin YX. Principal trabecular structural orientation predicted by quantitative ultrasound is strongly correlated with μFEA determined anisotropic apparent stiffness. Biomech Model Mechanobiol 2014; 13:961-71. [PMID: 24419558 DOI: 10.1007/s10237-013-0547-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Accepted: 12/12/2013] [Indexed: 10/25/2022]
Abstract
The microarchitecture and alignment of trabecular bone adapts to the particular mechanical milieu applied to it. Due to this anisotropic mechanical property, measurement orientation has to be taken into consideration when assessing trabecular bone quality and fracture risk prediction. Quantitative ultrasound (QUS) has demonstrated the ability in predicting the principal structural orientation (PSO) of trabecular bone. Although the QUS prediction for PSO is very close to that of μCT, certain angle differences still exist. It remains unknown whether this angle difference can induce significant differences in mechanical properties or not. The objective of this study was to evaluate the mechanical properties in different PSOs predicted using different methods, QUS and μCT, thus to investigate the ability of QUS as a means to predict the PSO of trabecular bone noninvasively. By validating the ability of QUS to predict the PSO of trabecular bone, it is beneficial for future QUS applications because QUS measurements in the PSO can provide information more correlated with the mechanical properties than with other orientations. In this study, seven trabecular bone balls from distal bovine femurs were used to generate finite element models based on the 3-dimensional μCT images. Uniaxial compressive loading was performed on the bone ball models in the finite element analysis (FEA) in six different orientations (three anatomical orientations, two PSOs predicted by QUS and the longest vector of mean intercept length (MIL) tensor calculated by μCT). The stiffness was calculated based on the reaction force of the bone balls under loading, and the von Mises stress results showed that both the mechanical properties in the PSOs predicted by QUS are significantly higher than the anatomical orientations and comparatively close to the longest vector of MIL tensor. The stiffness in the PSOs predicted by QUS is also highly correlated with the stiffness in the MIL tensor orientation (ATTmax vs. MIL, R(2) = 0.98, p < 001; UVmax vs. MIL, R(2) = 0.92, p < 001). These results were validated by in vitro mechanical testing on the bone ball samples. This study demonstrates that the PSO of trabecular bone predicted by QUS has an equally strong apparent stiffness with the orientation predicted by μCT.
Collapse
Affiliation(s)
- Liangjun Lin
- Orthopaedic Bioengineering Research Laboratory, Department of Biomedical Engineering, Stony Brook University, Bioengineering Building, Room 215, Stony Brook, NY , 11794-5281, USA
| | | | | | | |
Collapse
|
8
|
Hwang KS, Lee KI. Influence of cortical endplate on speed of sound in bovine femoral trabecular bone in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:EL463-EL469. [PMID: 23231209 DOI: 10.1121/1.4767449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Speed of sound (SOS) was measured in 14 bovine femoral trabecular bone samples with and without the cortical endplates with various thicknesses of 1.00, 1.31, 1.47, 1.75, and 2.00 mm. The presence of the cortical endplates resulted in an increase in the mean SOS of 16 m/s (+0.9%) to 91 m/s (+5.3%). The mean SOS measured in the samples with and without the cortical endplates exhibited similar significant correlations with apparent bone density (r = 0.86-0.91). All the SOS measurements were also found to be highly correlated with each other (r = 0.89-0.99).
Collapse
Affiliation(s)
- Kyo Seung Hwang
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea.
| | | |
Collapse
|
9
|
Lee KI. Ultrasonic properties in marrow-filled and water-filled bovine femoral trabecular bones in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:EL296-EL302. [PMID: 23039568 DOI: 10.1121/1.4751989] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Phase velocity and normalized broadband ultrasound attenuation (nBUA) were measured in 22 marrow-filled and water-filled bovine femoral trabecular bone samples. Replacement of marrow by water led to a significant increase in the mean phase velocity of 47 ± 12 m/s (+3.1%), but a decrease in the mean nBUA of 10.4 ± 2.9 dB/cm/MHz (-38.9%). All the ultrasonic properties in the marrow-filled and water-filled samples exhibited significant negative Pearson's correlation coefficients of r = -0.87 to -0.92 with porosity. High correlations were also observed between pairs of the ultrasonic properties, with r = 0.85 to 0.93.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 200-701, Republic of Korea.
| |
Collapse
|
10
|
Hoffman JJ, Nelson AM, Holland MR, Miller JG. Cancellous bone fast and slow waves obtained with Bayesian probability theory correlate with porosity from computed tomography. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:1830-7. [PMID: 22978910 PMCID: PMC3460989 DOI: 10.1121/1.4739455] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
A Bayesian probability theory approach for separating overlapping ultrasonic fast and slow waves in cancellous bone has been previously introduced. The goals of this study were to investigate whether the fast and slow waves obtained from Bayesian separation of an apparently single mode signal individually correlate with porosity and to isolate the fast and slow waves from medial-lateral insonification of the calcaneus. The Bayesian technique was applied to trabecular bone data from eight human calcanei insonified in the medial-lateral direction. The phase velocity, slope of attenuation (nBUA), and amplitude were determined for both the fast and slow waves. The porosity was assessed by micro-computed tomography (microCT) and ranged from 78.7% to 94.1%. The method successfully separated the fast and slow waves from medial-lateral insonification of the calcaneus. The phase velocity for both the fast and slow wave modes showed an inverse correlation with porosity (R(2) = 0.73 and R(2) = 0.86, respectively). The slope of attenuation for both wave modes also had a negative correlation with porosity (fast wave: R(2) = 0.73, slow wave: R(2) = 0.53). The fast wave amplitude decreased with increasing porosity (R(2) = 0.66). Conversely, the slow wave amplitude modestly increased with increasing porosity (R(2) = 0.39).
Collapse
Affiliation(s)
- Joseph J Hoffman
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63139, USA
| | | | | | | |
Collapse
|
11
|
Lin L, Cheng J, Lin W, Qin YX. Prediction of trabecular bone principal structural orientation using quantitative ultrasound scanning. J Biomech 2012; 45:1790-5. [PMID: 22560370 DOI: 10.1016/j.jbiomech.2012.04.022] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 04/12/2012] [Accepted: 04/13/2012] [Indexed: 11/15/2022]
Abstract
Bone has the ability to adapt its structure in response to the mechanical environment as defined as Wolff's Law. The alignment of trabecular structure is intended to adapt to the particular mechanical milieu applied to it. Due to the absence of normal mechanical loading, it will be extremely important to assess the anisotropic deterioration of bone during the extreme conditions, i.e., long term space mission and disease orientated disuse, to predict risk of fractures. The propagation of ultrasound wave in trabecular bone is substantially influenced by the anisotropy of the trabecular structure. Previous studies have shown that both ultrasound velocity and amplitude is dependent on the incident angle of the ultrasound signal into the bone sample. In this work, seven bovine trabecular bone balls were used for rotational ultrasound measurement around three anatomical axes to elucidate the ability of ultrasound to identify trabecular orientation. Both ultrasound attenuation (ATT) and fast wave velocity (UV) were used to calculate the principal orientation of the trabecular bone. By comparing to the mean intercept length (MIL) tensor obtained from μCT, the angle difference of the prediction by UV was 4.45°, while it resulted in 11.67° angle difference between direction predicted by μCT and the prediction by ATT. This result demonstrates the ability of ultrasound as a non-invasive measurement tool for the principal structural orientation of the trabecular bone.
Collapse
Affiliation(s)
- Liangjun Lin
- Orthopaedic Bioengineering Research Laboratory, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794-5281, USA
| | | | | | | |
Collapse
|
12
|
Nelson AM, Hoffman JJ, Anderson CC, Holland MR, Nagatani Y, Mizuno K, Matsukawa M, Miller JG. Determining attenuation properties of interfering fast and slow ultrasonic waves in cancellous bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 130:2233-40. [PMID: 21973378 PMCID: PMC3206914 DOI: 10.1121/1.3625241] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Previous studies have shown that interference between fast waves and slow waves can lead to observed negative dispersion in cancellous bone. In this study, the effects of overlapping fast and slow waves on measurements of the apparent attenuation as a function of propagation distance are investigated along with methods of analysis used to determine the attenuation properties. Two methods are applied to simulated data that were generated based on experimentally acquired signals taken from a bovine specimen. The first method uses a time-domain approach that was dictated by constraints imposed by the partial overlap of fast and slow waves. The second method uses a frequency-domain log-spectral subtraction technique on the separated fast and slow waves. Applying the time-domain analysis to the broadband data yields apparent attenuation behavior that is larger in the early stages of propagation and decreases as the wave travels deeper. In contrast, performing frequency-domain analysis on the separated fast waves and slow waves results in attenuation coefficients that are independent of propagation distance. Results suggest that features arising from the analysis of overlapping two-mode data may represent an alternate explanation for the previously reported apparent dependence on propagation distance of the attenuation coefficient of cancellous bone.
Collapse
Affiliation(s)
- Amber M Nelson
- Department of Physics, Washington University in Saint Louis, Saint Louis, Missouri 63130, USA
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Anderson CC, Bauer AQ, Holland MR, Pakula M, Laugier P, Bretthorst GL, Miller JG. Inverse problems in cancellous bone: estimation of the ultrasonic properties of fast and slow waves using Bayesian probability theory. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 128:2940-8. [PMID: 21110589 PMCID: PMC3003723 DOI: 10.1121/1.3493441] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2010] [Revised: 08/23/2010] [Accepted: 08/31/2010] [Indexed: 05/05/2023]
Abstract
Quantitative ultrasonic characterization of cancellous bone can be complicated by artifacts introduced by analyzing acquired data consisting of two propagating waves (a fast wave and a slow wave) as if only one wave were present. Recovering the ultrasonic properties of overlapping fast and slow waves could therefore lead to enhancement of bone quality assessment. The current study uses Bayesian probability theory to estimate phase velocity and normalized broadband ultrasonic attenuation (nBUA) parameters in a model of fast and slow wave propagation. Calculations are carried out using Markov chain Monte Carlo with simulated annealing to approximate the marginal posterior probability densities for parameters in the model. The technique is applied to simulated data, to data acquired on two phantoms capable of generating two waves in acquired signals, and to data acquired on a human femur condyle specimen. The models are in good agreement with both the simulated and experimental data, and the values of the estimated ultrasonic parameters fall within expected ranges.
Collapse
Affiliation(s)
- Christian C Anderson
- Department of Physics, Washington University in St Louis, St Louis, Missouri 63130, USA
| | | | | | | | | | | | | |
Collapse
|
14
|
Aygün H, Attenborough K, Lauriks W, Langton CM. Ultrasonic wave propagation in stereo-lithographical bone replicas. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:3781-3789. [PMID: 20550276 DOI: 10.1121/1.3397581] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Predictions of a modified anisotropic Biot-Allard theory are compared with measurements of pulses centered on 100 kHz and 1 MHz transmitted through water-saturated stereo-lithographical bone replicas. The replicas are 13 times larger than the original bone samples. Despite the expected effects of scattering, which is neglected in the theory, at 100 kHz the predicted and measured transmitted waveforms are similar. However, the magnitude of the leading negative edge of the waveform is overpredicted, and the trailing parts of the waveforms are not predicted well. At 1 MHz, although there are differences in amplitudes, the theory predicts that the transmitted waveform is almost a scaled version of that incident in conformity with the data.
Collapse
Affiliation(s)
- Haydar Aygün
- Medical Physics, Post-Graduate Medical Institute, The University of Hull, Cottingham Road, Hull HU6 7RX, United Kingdom
| | | | | | | |
Collapse
|
15
|
Aygün H, Attenborough K, Postema M, Lauriks W, Langton CM. Predictions of angle dependent tortuosity and elasticity effects on sound propagation in cancellous bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2009; 126:3286-3290. [PMID: 20000942 DOI: 10.1121/1.3242358] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The anisotropic pore structure and elasticity of cancellous bone cause wave speeds and attenuation in cancellous bone to vary with angle. Previously published predictions of the variation in wave speed with angle are reviewed. Predictions that allow tortuosity to be angle dependent but assume isotropic elasticity compare well with available data on wave speeds at large angles but less well for small angles near the normal to the trabeculae. Claims for predictions that only include angle-dependence in elasticity are found to be misleading. Audio-frequency data obtained at audio-frequencies in air-filled bone replicas are used to derive an empirical expression for the angle-and porosity-dependence of tortuosity. Predictions that allow for either angle dependent tortuosity or angle dependent elasticity or both are compared with existing data for all angles and porosities.
Collapse
Affiliation(s)
- Haydar Aygün
- Medical Physics, PGMI, The University of Hull, Cottingham Road, HU6 7RX Hull, United Kingdom.
| | | | | | | | | |
Collapse
|
16
|
Anderson CC, Marutyan KR, Holland MR, Wear KA, Miller JG. Interference between wave modes may contribute to the apparent negative dispersion observed in cancellous bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 124:1781-9. [PMID: 19045668 PMCID: PMC2597053 DOI: 10.1121/1.2953309] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2008] [Revised: 06/03/2008] [Accepted: 06/05/2008] [Indexed: 05/22/2023]
Abstract
Previous work has shown that ultrasonic waves propagating through cancellous bone often exhibit a linear-with-frequency attenuation coefficient, but a decrease in phase velocity with frequency (negative dispersion) that is inconsistent with the causality-imposed Kramers-Kronig relations. In the current study, interfering wave modes similar to those observed in bone are shown to potentially contribute to the observed negative dispersion. Biot theory, the modified Biot-Attenborogh model, and experimental results are used to aid in simulating multiple-mode wave propagation through cancellous bone. Simulations entail constructing individual wave modes exhibiting a positive dispersion using plausible velocities and amplitudes, and then summing the individual modes to create mixed-mode output wave forms. Results of the simulations indicate that mixed-mode wave forms can exhibit negative dispersion when analyzed conventionally under the assumption that only one wave is present, even when the individual interfering waves exhibit positive dispersions in accordance with the Kramers-Kronig relations. Furthermore, negative dispersion is observed when little or no visual evidence of interference exists in the time-domain data. Understanding the mechanisms responsible for the observed negative dispersion could aid in determining the true material properties of cancellous bone, as opposed to the apparent properties measured using conventional data analysis techniques.
Collapse
Affiliation(s)
- Christian C Anderson
- Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63130, USA
| | | | | | | | | |
Collapse
|
17
|
Haiat G, Padilla F, Laugier P. Sensitivity of qus parameters to controlled variations of bone strength assessed with a cellular model. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1488-1496. [PMID: 18986938 DOI: 10.1109/tuffc.2008.824] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The physical principles underlying quantitative ultrasound (QUS) measurements are not fully understood yet. Therefore, the translation of QUS results into bone strength remains elusive. In the present study, we derive the sensitivity of broadband ultrasonic attenuation (BUA) and speed of sound (SOS) to variations of bone strength. For this purpose, a mechanical cellular model is combined to a multiple regression resulting from the analysis of finite-difference time domain (FDTD) simulations. Specifically, we investigate how QUS variables respond to a variation in strength of 10%, realized either by a change in material properties or a change in bone volume fraction (BV/TV). The results show that except when BV/TV is high, the variations of BUA in response to a variation in strength realized by a pure change of BV/TV exceeds the technique imprecision and thus can be detected. When the variation of strength is realized by changes of compressive or shear stiffness, the response in QUS properties is dominated by the variation in C(11), whereas changes in C(44), remaining below the precision error, cannot be detected. The interpretation of these data, however, is not straightforward due to sparse description of elastic properties at the tissue level. To overcome the limitation of the cellular model, more realistic computational models such as micro- finite element analysis have to be considered.
Collapse
Affiliation(s)
- G Haiat
- Centre Nat. de la Rech. Sci. (CNRS), Univ. Paris Diderot, Paris, France.
| | | | | |
Collapse
|
18
|
Haïat G, Padilla F, Peyrin F, Laugier P. Fast wave ultrasonic propagation in trabecular bone: numerical study of the influence of porosity and structural anisotropy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:1694-705. [PMID: 18345857 DOI: 10.1121/1.2832611] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Our goal is to assess the potential of computational methods as an alternative to analytical models to predict the two longitudinal wave modes observed in cancellous bone and predicted by the Biot theory. A three-dimensional (3D) finite-difference time-domain method is coupled with 34 human femoral trabecular microstructures measured using microcomputed tomography. The main trabecular alignment (MTA) and the degree of anisotropy (DA) were assessed for all samples. DA values were comprised between 1.02 and 1.9. The influence of bone volume fraction (BV/TV) between 5% and 25% on the properties of the fast and slow waves was studied using a dedicated image processing algorithm to modify the initial 3D microstructures. A heuristic method was devised to determine when both wave modes are time separated. The simulations (performed in three perpendicular directions) predicted that both waves generally overlap in time for a direction of propagation perpendicular to the MTA. When these directions are parallel, both waves are separated in time for samples with high DA and BV/TV values. A relationship was found between the least bone volume fraction required for the observation of nonoverlapping waves and the degree of anisotropy: The higher the DA, the lower the least BV/TV.
Collapse
Affiliation(s)
- G Haïat
- CNRS, Université Paris 7, Laboratoire de Recherches Orthopédiques, UMR CNRS 7052 B2OA, 10, avenue de Verdun, 75010 Paris, France.
| | | | | | | |
Collapse
|
19
|
Laugier P. Instrumentation for in vivo ultrasonic characterization of bone strength. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1179-96. [PMID: 18599407 DOI: 10.1109/tuffc.2008.782] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Although it has been more than 20 years since the first recorded use of a quantitative ultrasound (QUS) technology to predict bone fragility, the field has not yet reached its maturity. QUS has the potential to predict fracture risk in several clinical circumstances and has the advantages of being nonionizing, inexpensive, portable, highly acceptable to patients, and repeatable. However, the wide dissemination of QUS in clinical practice is still limited and suffering from the absence of clinical consensus on how to integrate QUS technologies in bone densitometry armamentarium. Several critical issues need to be addressed to develop the role of QUS within rheumatology. These include issues of technologies adapted to measure the central skeleton, data acquisition, and signal processing procedures to reveal bone properties beyond bone mineral quantity and elucidation of the complex interaction between ultrasound and bone structure. This article reviews the state-of-the art in technological developments applied to assess bone strength in vivo. We describe generic measurement and signal processing methods implemented in clinical ultrasound devices, the devices and their practical use, and performance measures. The article also points out the present limitations, especially those related to the absence of standardization, and the lack of comprehensive theoretical models. We conclude with suggestions of future lines and trends in technology challenges and research areas such as new acquisition modes, advanced signal processing techniques, and modelization.
Collapse
Affiliation(s)
- Pascal Laugier
- Université Pierre et Marie Curie-Paris 5, Laboratoire d'Imagerie Paramétrique, Paris, France.
| |
Collapse
|