Wang L, Meng M, Chen S, Bian Z, Zeng D, Meng D, Ma J. Semi-supervised iterative adaptive network for low-dose CT sinogram recovery. Phys Med Biol 2024; 69:085013. [PMID: 38422540 DOI: 10.1088/1361-6560/ad2ee7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 02/29/2024] [Indexed: 03/02/2024]
Abstract
Background.Concern has been expressed regarding the risk of carcinogenesis from medical computed tomography (CT) radiation. Lowering radiation in CT without appropriate modifications often leads to severe noise-induced artifacts in the images. The utilization of deep learning (DL) techniques has achieved promising reconstruction performance in low-dose CT (LDCT) imaging. However, most DL-based algorithms require the pre-collection of a large set of image pairs (low-dose/standard-dose) and the training of networks in an end-to-end supervised manner. Meanwhile, securing such a large volume of paired, well-registered training data in clinical practice is challenging. Moreover, these algorithms often overlook the potential to utilize the abundant information in a large collection of LDCT-only images/sinograms.Methods.In this paper, we introduce a semi-supervised iterative adaptive network (SIA-Net) for LDCT imaging, utilizing both labeled and unlabeled sinograms in a cohesive network framework, integrating supervised and unsupervised learning processes. Specifically, the supervised process captures critical features (i.e. noise distribution and tissue characteristics) latent in the paired sinograms, while the unsupervised process effectively learns these features in the unlabeled low-dose sinograms, employing a conventional weighted least-squares model with a regularization term. Furthermore, the SIA-Net method is designed to adaptively transfer the learned feature distribution from the supervised to the unsupervised process, thereby obtaining a high-fidelity sinogram through iterative adaptive learning. Finally, high-quality CT images can be reconstructed from the refined sinogram using the filtered back-projection algorithm.Results.Experimental results on two clinical datasets indicate that the proposed SIA-Net method achieves competitive performance in terms of noise reduction and structure preservation in LDCT imaging, when compared to traditional supervised learning methods.
Collapse
Affiliation(s)
- Lei Wang
- School of Future Technology, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China
| | - Mingqiang Meng
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China
- Pazhou Lab (Huangpu), Guangdong, People's Republic of China
| | - Shixuan Chen
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China
| | - Zhaoying Bian
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China
- Pazhou Lab (Huangpu), Guangdong, People's Republic of China
| | - Dong Zeng
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China
- Pazhou Lab (Huangpu), Guangdong, People's Republic of China
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangdong, People's Republic of China
| | - Deyu Meng
- School of Mathematics and Statistics, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China
| | - Jianhua Ma
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, People's Republic of China
- School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, People's Republic of China
| |
Collapse
|
2
|
高 琦, 朱 曼, 李 丹, 边 兆, 马 建. [CT image quality assessment based on prior information of pre-restored images]. NAN FANG YI KE DA XUE XUE BAO = JOURNAL OF SOUTHERN MEDICAL UNIVERSITY 2021; 41:230-237. [PMID: 33624596 PMCID: PMC7905247 DOI: 10.12122/j.issn.1673-4254.2021.02.10] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Indexed: 06/12/2023]
Abstract
OBJECTIVE We propose a CT IQA strategy based on the prior information of pre-restored images (PR-IQA) to improve the performance of IQA models. OBJECTIVE We propose a CNN-based no-reference CT IQA strategy using the prior information of image quality features in the image restoration algorithm, which is combined with the original distorted image information into the two CNNs through the pre-restored image and the residual image. Multi-information fusion was used to improve the feature extraction ability and prediction performance of CNN. We built a CT IQA dataset based on spiral CT data published by Mayo Clinic. The performance of PR- IQA was evaluated by calculating the quantitative metrics and statistical tests. The influence of different hyperparameter settings for PR-IQA was analyzed. We then compared PR-IQA with the BASELINE model based on the single CNN to evaluate the original distorted image without reference image and other eight IQA algorithms. OBJECTIVE The comparative experiment results showed that the PR-IQA model based on the prior information of 3 different image restoration algorithms (BF, NLM and BM3D) was better than all the tested IQA algorithms. Compared with the BASELINE method, the proposed method showed significantly improved performance, and the mean PLCC was increased by 12.56% and SROCC by 19.95%, and RMSE was decreased by 22.77%. OBJECTIVE The proposed PR-IQA method can make full use of the prior information of the image restoration algorithm to effectively predict the quality of CT images.
Collapse
Affiliation(s)
- 琦 高
- />南方医科大学生物医学工程学院//广州市医用放射成像与检测技术重点实验室,广东 广州 510515School of Biomedical Engineering, Southern Medical University; Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Guangzhou 510515, China
| | - 曼曼 朱
- />南方医科大学生物医学工程学院//广州市医用放射成像与检测技术重点实验室,广东 广州 510515School of Biomedical Engineering, Southern Medical University; Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Guangzhou 510515, China
| | - 丹阳 李
- />南方医科大学生物医学工程学院//广州市医用放射成像与检测技术重点实验室,广东 广州 510515School of Biomedical Engineering, Southern Medical University; Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Guangzhou 510515, China
| | - 兆英 边
- />南方医科大学生物医学工程学院//广州市医用放射成像与检测技术重点实验室,广东 广州 510515School of Biomedical Engineering, Southern Medical University; Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Guangzhou 510515, China
| | - 建华 马
- />南方医科大学生物医学工程学院//广州市医用放射成像与检测技术重点实验室,广东 广州 510515School of Biomedical Engineering, Southern Medical University; Guangzhou Key Laboratory of Medical Radiation Imaging and Detection Technology, Guangzhou 510515, China
| |
Collapse
|
3
|
Xie Q, Zeng D, Zhao Q, Meng D, Xu Z, Liang Z, Ma J. Robust Low-Dose CT Sinogram Preprocessing via Exploiting Noise-Generating Mechanism. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:2487-2498. [PMID: 29192885 PMCID: PMC5718215 DOI: 10.1109/tmi.2017.2767290] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Computed tomography (CT) image recovery from low-mAs acquisitions without adequate treatment is always severely degraded due to a number of physical factors. In this paper, we formulate the low-dose CT sinogram preprocessing as a standard maximum a posteriori (MAP) estimation, which takes full consideration of the statistical properties of the two intrinsic noise sources in low-dose CT, i.e., the X-ray photon statistics and the electronic noise background. In addition, instead of using a general image prior as found in the traditional sinogram recovery models, we design a new prior formulation to more rationally encode the piecewise-linear configurations underlying a sinogram than previously used ones, like the TV prior term. As compared with the previous methods, especially the MAP-based ones, both the likelihood/loss and prior/regularization terms in the proposed model are ameliorated in a more accurate manner and better comply with the statistical essence of the generation mechanism of a practical sinogram. We further construct an efficient alternating direction method of multipliers algorithm to solve the proposed MAP framework. Experiments on simulated and real low-dose CT data demonstrate the superiority of the proposed method according to both visual inspection and comprehensive quantitative performance evaluation.
Collapse
|
4
|
Little KJ, La Rivière PJ. Sinogram restoration in computed tomography with an edge-preserving penalty. Med Phys 2016; 42:1307-20. [PMID: 25735286 DOI: 10.1118/1.4907968] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE With the goal of producing a less computationally intensive alternative to fully iterative penalized-likelihood image reconstruction, our group has explored the use of penalized-likelihood sinogram restoration for transmission tomography. Previously, we have exclusively used a quadratic penalty in our restoration objective function. However, a quadratic penalty does not excel at preserving edges while reducing noise. Here, we derive a restoration update equation for nonquadratic penalties. Additionally, we perform a feasibility study to extend our sinogram restoration method to a helical cone-beam geometry and clinical data. METHODS A restoration update equation for nonquadratic penalties is derived using separable parabolic surrogates (SPS). A method for calculating sinogram degradation coefficients for a helical cone-beam geometry is proposed. Using simulated data, sinogram restorations are performed using both a quadratic penalty and the edge-preserving Huber penalty. After sinogram restoration, Fourier-based analytical methods are used to obtain reconstructions, and resolution-noise trade-offs are investigated. For the fan-beam geometry, a comparison is made to image-domain SPS reconstruction using the Huber penalty. The effects of varying object size and contrast are also investigated. For the helical cone-beam geometry, we investigate the effect of helical pitch (axial movement/rotation). Huber-penalty sinogram restoration is performed on 3D clinical data, and the reconstructed images are compared to those generated with no restoration. RESULTS We find that by applying the edge-preserving Huber penalty to our sinogram restoration methods, the reconstructed image has a better resolution-noise relationship than an image produced using a quadratic penalty in the sinogram restoration. However, we find that this relatively straightforward approach to edge preservation in the sinogram domain is affected by the physical size of imaged objects in addition to the contrast across the edge. This presents some disadvantages of this method relative to image-domain edge-preserving methods, although the computational burden of the sinogram-domain approach is much lower. For a helical cone-beam geometry, we found applying sinogram restoration in 3D was reasonable and that pitch did not make a significant difference in the general effect of sinogram restoration. The application of Huber-penalty sinogram restoration to clinical data resulted in a reconstruction with less noise while retaining resolution. CONCLUSIONS Sinogram restoration with the Huber penalty is able to provide better resolution-noise performance than restoration with a quadratic penalty. Additionally, sinogram restoration with the Huber penalty is feasible for helical cone-beam CT and can be applied to clinical data.
Collapse
Affiliation(s)
- Kevin J Little
- Department of Radiology, The University of Chicago, Chicago, Illinois 60637
| | | |
Collapse
|
5
|
Karimi D, Ward R. A denoising algorithm for projection measurements in cone-beam computed tomography. Comput Biol Med 2016; 69:71-82. [PMID: 26735188 DOI: 10.1016/j.compbiomed.2015.12.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2015] [Revised: 12/08/2015] [Accepted: 12/10/2015] [Indexed: 10/22/2022]
Abstract
The ability to reduce the radiation dose in computed tomography (CT) is limited by the excessive quantum noise present in the projection measurements. Sinogram denoising is, therefore, an essential step towards reconstructing high-quality images, especially in low-dose CT. Effective denoising requires accurate modeling of the photon statistics and of the prior knowledge about the characteristics of the projection measurements. This paper proposes an algorithm for denoising low-dose sinograms in cone-beam CT. The proposed algorithm is based on minimizing a cost function that includes a measurement consistency term and two regularizations in terms of the gradient and the Hessian of the sinogram. This choice of the regularization is motivated by the nature of CT projections. We use a split Bregman algorithm to minimize the proposed cost function. We apply the algorithm on simulated and real cone-beam projections and compare the results with another algorithm based on bilateral filtering. Our experiments with simulated and real data demonstrate the effectiveness of the proposed algorithm. Denoising of the projections with the proposed algorithm leads to a significant reduction of the noise in the reconstructed images without oversmoothing the edges or introducing artifacts.
Collapse
Affiliation(s)
- Davood Karimi
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada.
| | - Rabab Ward
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada
| |
Collapse
|
6
|
Karimi D, Deman P, Ward R, Ford N. A sinogram denoising algorithm for low-dose computed tomography. BMC Med Imaging 2016; 16:11. [PMID: 26800667 PMCID: PMC4724114 DOI: 10.1186/s12880-016-0112-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Accepted: 01/13/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND From the viewpoint of the patients' health, reducing the radiation dose in computed tomography (CT) is highly desirable. However, projection measurements acquired under low-dose conditions will contain much noise. Therefore, reconstruction of high-quality images from low-dose scans requires effective denoising of the projection measurements. METHODS We propose a denoising algorithm that is based on maximizing the data likelihood and sparsity in the gradient domain. For Poisson noise, this formulation automatically leads to a locally adaptive denoising scheme. Because the resulting optimization problem is hard to solve and may also lead to artifacts, we suggest an explicitly local denoising method by adapting an existing algorithm for normally-distributed noise. We apply the proposed method on sets of simulated and real cone-beam projections and compare its performance with two other algorithms. RESULTS The proposed algorithm effectively suppresses the noise in simulated and real CT projections. Denoising of the projections with the proposed algorithm leads to a substantial improvement of the reconstructed image in terms of noise level, spatial resolution, and visual quality. CONCLUSION The proposed algorithm can suppress very strong quantum noise in CT projections. Therefore, it can be used as an effective tool in low-dose CT.
Collapse
Affiliation(s)
| | - Pierre Deman
- 2151 Wesbrook Mall, Vancouver, V6T 1Z3, BC, Canada.
| | - Rabab Ward
- 2366 Main Mall, Vancouver, V6T 1Z4, BC, Canada.
| | - Nancy Ford
- 2151 Wesbrook Mall, Vancouver, V6T 1Z3, BC, Canada.
| |
Collapse
|
7
|
Xu J, Fuld MK, Fung GSK, Tsui BMW. Task-based image quality evaluation of iterative reconstruction methods for low dose CT using computer simulations. Phys Med Biol 2015; 60:2881-901. [PMID: 25776521 DOI: 10.1088/0031-9155/60/7/2881] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Iterative reconstruction (IR) methods for x-ray CT is a promising approach to improve image quality or reduce radiation dose to patients. The goal of this work was to use task based image quality measures and the channelized Hotelling observer (CHO) to evaluate both analytic and IR methods for clinical x-ray CT applications. We performed realistic computer simulations at five radiation dose levels, from a clinical reference low dose D0 to 25% D0. A fixed size and contrast lesion was inserted at different locations into the liver of the XCAT phantom to simulate a weak signal. The simulated data were reconstructed on a commercial CT scanner (SOMATOM Definition Flash; Siemens, Forchheim, Germany) using the vendor-provided analytic (WFBP) and IR (SAFIRE) methods. The reconstructed images were analyzed by CHOs with both rotationally symmetric (RS) and rotationally oriented (RO) channels, and with different numbers of lesion locations (5, 10, and 20) in a signal known exactly (SKE), background known exactly but variable (BKEV) detection task. The area under the receiver operating characteristic curve (AUC) was used as a summary measure to compare the IR and analytic methods; the AUC was also used as the equal performance criterion to derive the potential dose reduction factor of IR. In general, there was a good agreement in the relative AUC values of different reconstruction methods using CHOs with RS and RO channels, although the CHO with RO channels achieved higher AUCs than RS channels. The improvement of IR over analytic methods depends on the dose level. The reference dose level D0 was based on a clinical low dose protocol, lower than the standard dose due to the use of IR methods. At 75% D0, the performance improvement was statistically significant (p < 0.05). The potential dose reduction factor also depended on the detection task. For the SKE/BKEV task involving 10 lesion locations, a dose reduction of at least 25% from D0 was achieved.
Collapse
Affiliation(s)
- Jingyan Xu
- Division of Medical Imaging Physics, The Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD 21218, USA
| | | | | | | |
Collapse
|
8
|
Hofmann C, Knaup M, Kachelrieß M. Effects of ray profile modeling on resolution recovery in clinical CT. Med Phys 2014; 41:021907. [DOI: 10.1118/1.4862510] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
9
|
Nuyts J, De Man B, Fessler JA, Zbijewski W, Beekman FJ. Modelling the physics in the iterative reconstruction for transmission computed tomography. Phys Med Biol 2013. [PMID: 23739261 DOI: 10.1088/0031‐9155/58/12/r63] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
There is an increasing interest in iterative reconstruction (IR) as a key tool to improve quality and increase applicability of x-ray CT imaging. IR has the ability to significantly reduce patient dose; it provides the flexibility to reconstruct images from arbitrary x-ray system geometries and allows one to include detailed models of photon transport and detection physics to accurately correct for a wide variety of image degrading effects. This paper reviews discretization issues and modelling of finite spatial resolution, Compton scatter in the scanned object, data noise and the energy spectrum. The widespread implementation of IR with a highly accurate model-based correction, however, still requires significant effort. In addition, new hardware will provide new opportunities and challenges to improve CT with new modelling.
Collapse
Affiliation(s)
- Johan Nuyts
- Department of Nuclear Medicine and Medical Imaging Research Center, KU Leuven, Leuven, Belgium.
| | | | | | | | | |
Collapse
|
10
|
Nuyts J, De Man B, Fessler JA, Zbijewski W, Beekman FJ. Modelling the physics in the iterative reconstruction for transmission computed tomography. Phys Med Biol 2013; 58:R63-96. [PMID: 23739261 PMCID: PMC3725149 DOI: 10.1088/0031-9155/58/12/r63] [Citation(s) in RCA: 97] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
There is an increasing interest in iterative reconstruction (IR) as a key tool to improve quality and increase applicability of x-ray CT imaging. IR has the ability to significantly reduce patient dose; it provides the flexibility to reconstruct images from arbitrary x-ray system geometries and allows one to include detailed models of photon transport and detection physics to accurately correct for a wide variety of image degrading effects. This paper reviews discretization issues and modelling of finite spatial resolution, Compton scatter in the scanned object, data noise and the energy spectrum. The widespread implementation of IR with a highly accurate model-based correction, however, still requires significant effort. In addition, new hardware will provide new opportunities and challenges to improve CT with new modelling.
Collapse
Affiliation(s)
- Johan Nuyts
- Department of Nuclear Medicine and Medical Imaging Research Center, KU Leuven, Leuven, Belgium.
| | | | | | | | | |
Collapse
|
11
|
Beister M, Kolditz D, Kalender WA. Iterative reconstruction methods in X-ray CT. Phys Med 2012; 28:94-108. [PMID: 22316498 DOI: 10.1016/j.ejmp.2012.01.003] [Citation(s) in RCA: 379] [Impact Index Per Article: 31.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2011] [Revised: 01/12/2012] [Accepted: 01/15/2012] [Indexed: 10/14/2022] Open
Abstract
Iterative reconstruction (IR) methods have recently re-emerged in transmission x-ray computed tomography (CT). They were successfully used in the early years of CT, but given up when the amount of measured data increased because of the higher computational demands of IR compared to analytical methods. The availability of large computational capacities in normal workstations and the ongoing efforts towards lower doses in CT have changed the situation; IR has become a hot topic for all major vendors of clinical CT systems in the past 5 years. This review strives to provide information on IR methods and aims at interested physicists and physicians already active in the field of CT. We give an overview on the terminology used and an introduction to the most important algorithmic concepts including references for further reading. As a practical example, details on a model-based iterative reconstruction algorithm implemented on a modern graphics adapter (GPU) are presented, followed by application examples for several dedicated CT scanners in order to demonstrate the performance and potential of iterative reconstruction methods. Finally, some general thoughts regarding the advantages and disadvantages of IR methods as well as open points for research in this field are discussed.
Collapse
Affiliation(s)
- Marcel Beister
- Institute of Medical Physics (IMP), Unversity of Erlangen-Nürnberg, Erlangen, Germany
| | | | | |
Collapse
|
12
|
Forthmann P, Koehler T, Defrise M, La Riviere P. Comparing implementations of penalized weighted least-squares sinogram restoration. Med Phys 2011; 37:5929-38. [PMID: 21158306 DOI: 10.1118/1.3490476] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE A CT scanner measures the energy that is deposited in each channel of a detector array by x rays that have been partially absorbed on their way through the object. The measurement process is complex and quantitative measurements are always and inevitably associated with errors, so CT data must be preprocessed prior to reconstruction. In recent years, the authors have formulated CT sinogram preprocessing as a statistical restoration problem in which the goal is to obtain the best estimate of the line integrals needed for reconstruction from the set of noisy, degraded measurements. The authors have explored both penalized Poisson likelihood (PL) and penalized weighted least-squares (PWLS) objective functions. At low doses, the authors found that the PL approach outperforms PWLS in terms of resolution-noise tradeoffs, but at standard doses they perform similarly. The PWLS objective function, being quadratic, is more amenable to computational acceleration than the PL objective. In this work, the authors develop and compare two different methods for implementing PWLS sinogram restoration with the hope of improving computational performance relative to PL in the standard-dose regime. Sinogram restoration is still significant in the standard-dose regime since it can still outperform standard approaches and it allows for correction of effects that are not usually modeled in standard CT preprocessing. METHODS The authors have explored and compared two implementation strategies for PWLS sinogram restoration: (1) A direct matrix-inversion strategy based on the closed-form solution to the PWLS optimization problem and (2) an iterative approach based on the conjugate-gradient algorithm. Obtaining optimal performance from each strategy required modifying the naive off-the-shelf implementations of the algorithms to exploit the particular symmetry and sparseness of the sinogram-restoration problem. For the closed-form approach, the authors subdivided the large matrix inversion into smaller coupled problems and exploited sparseness to minimize matrix operations. For the conjugate-gradient approach, the authors exploited sparseness and preconditioned the problem to speed up convergence. RESULTS All methods produced qualitatively and quantitatively similar images as measured by resolution-variance tradeoffs and difference images. Despite the acceleration strategies, the direct matrix-inversion approach was found to be uncompetitive with iterative approaches, with a computational burden higher by an order of magnitude or more. The iterative conjugate-gradient approach, however, does appear promising, with computation times half that of the authors' previous penalized-likelihood implementation. CONCLUSIONS Iterative conjugate-gradient based PWLS sinogram restoration with careful matrix optimizations has computational advantages over direct matrix PWLS inversion and over penalized-likelihood sinogram restoration and can be considered a good alternative in standard-dose regimes.
Collapse
Affiliation(s)
- Peter Forthmann
- Philips Research Europe, Röntgenstrasse 24-26, 22315 Hamburg, Germany
| | | | | | | |
Collapse
|
13
|
Adil EA, Choudhary AK, Moser KW, Ghossaini SN. Vestibular pneumolabyrinth: why assessment with temporal bone computed tomography utilizing dynamic focal spot mode is important for the diagnosis. Emerg Radiol 2010; 18:43-5. [PMID: 20827498 DOI: 10.1007/s10140-010-0902-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2010] [Accepted: 08/19/2010] [Indexed: 11/27/2022]
Abstract
We present an interesting and relatively uncommon case of vestibular pneumolabyrinth in a young child post-trauma. His initial clinical exam and imaging studies of the head and cervical spine were negative. He subsequently developed nystagmus and a dedicated temporal bone study demonstrated a subtle fracture and vestibular pneumolabyrinth. Temporal bone fractures can be difficult to appreciate, and therefore, associated findings of fluid in the middle ear, stapes dislocation, or vestibular pneumolabyrinth must be carefully evaluated. Temporal bone computed tomography is a high resolution study, utilizing dynamic focal spot mode which leads to increased sampling and resolution, thereby reducing aliasing artifacts but a longer scan time and increased radiation dose. CT head and cervical spine normally obtained without using this technique leads to aliasing artifacts where even the normal endolymph in the inner ear structures appear hypodense mimicking pneumolabyrinth, thereby obscuring true pneumolabyrinth. It is important to be aware of this finding and technique-related artifact, if a temporal bone injury is suspected, to ensure an earlier diagnosis and optimum management.
Collapse
Affiliation(s)
- Eelam A Adil
- Division of Otolaryngology-Head and Neck Surgery, Pennsylvania State University, Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA 17033, USA.
| | | | | | | |
Collapse
|